Tender For General Electric Repairs To The Academic,Administrative Buildings, Hostels, Guest House And Staff Quartrs At Old And New University C Us, Of University Of Jammu. Jammu
Tender Value
14.83 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
5 days left
EMD
29671
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General Electric Repairs To The Academic,Administrative Buildings, Hostels, Guest House And Staff Quartrs At Old And New University C Us, Of University Of Jammu. Jammu
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/fan point/ceiling fan point/exhaust fan point/call bell point with 1.5 Sq. mm FRLS/HFFR PVC insulated, copper conductor cable in surface/recessed medium class PVC conduit, with piano type switch, phenolic, laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq mm. FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. (Wire Make ISI Marked Havells/Anchor /KEI/Polycab, Plaza Conduit Make - ISI Marked Anchor/High Power /AKG) Equivalent make of required specification to be approved by the Engineer In charge) i.Group ‘A’ |
| 2 | ii.Group ‘B’ |
| 3 | ii.Group ‘C’ |
| 4 | Wiring for circuit/sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.(Wire Make ISI Marked Havells/Anchor/KEI/Plaza/polycab Equivalent make of required specification to be approved by the Engineer In charge )i. 2x1.5 +1x1.5 Sq mm |
| 5 | i. 2x2.5+ 1x2.5 Sq mm |
| 6 | ii. 2x4 + 1x4 Sq mm |
| 7 | iii. 2x6 +1x6 Sq mm |
| 8 | iv. 4x6 +2x6 Sq mm |
| 9 | v. 4x10 +2x6 Sq mm |
| 10 | Supplying and fixing of following sizes of medium class PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required- ISI Marked Anchor/High Power /AKG)25 mm dia |
| 11 | Supplying and fixing 5 amp to 32 amps rating, 240/415 volts, 10 KA C curve miniature circuit breaker suitable for inductive load of following poles of in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Make Havells /Anchor/HPL Equivalent make of required specification to be approved by the Engineer In charge) i. Single pole |
| 12 | Earthing with Copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 13 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 14 | Supply and fixing of metal Box of following size(nominal size) on the surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required 100mm x 100mm x 60mm deep |
| 15 | 200mm x 125mm x 60mm deep |
| 16 | Supply & fixing following piano type switch/socket on the existing switch box/cover including connection etc as required. (Make: Anchor/Havells/Philips/Polycap major Equivalent make of required specification to be approved by the Engineer In charge) i.5/6 Amp Switch |
| 17 | ii.15/16 Amp Switch |
| 18 | iii.3 pin 5/6 Amp Socket |
| 19 | iv.6 pin 15/16 Amp Socket |
| 20 | v.Telephone Socket outlet |
| 21 | vi.TV antenna socket outlet |
| 22 | Supply & fixing following modular type switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Anchor/Havells /HPL/Great White Equivalent make of required specification to be approved by the Engineer In charge) i.5/6 Amp Switch |
| 23 | ii.15/16 Amp Switch |
| 24 | iii.3 pin 5/6 Amp Socket |
| 25 | iv.6 pin 5/6 Amp Socket |
| 26 | Supply and fixing of following size/module, GI box along with modular base and cover plate for modular switches in recess etc. as reqd A.12 Module |
| 27 | B.6 Module |
| 28 | C. 3 Module |
| 29 | D. 1 or 2 Module |
| 30 | E.8 Module |
| 31 | Supplying and fixing following ways and single pole and neutral,sheet steel,MCB distribution board,240V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators)( Havells/Anchor /I.A /HPL)i. 8 way, Double door |
| 32 | ii. 12 way, Double door |
| 33 | Supplying and fixing following way, horizontal type three pole and neutral,sheet steel,MCB distribution board,415 V,on surface/recess,complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolators)( Havells/Anchor /I.A /HPL Equivalent make of required specification to be approved by the Engineer In charge)i. 6 way(4+18), Double door |
| 34 | ii. 8 way(4+24), Double door |
| 35 | Supplying & drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor un armoured telephone cables in the existing surface/recessed steel / PVC Conduit as required (Make ISI Marked Havells/Anchor/ KEI Equivalent make of required specification to be approved by the Engineer In charge)2 Pair |
| 36 | Supply & fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Make Havells/ Anchor /Major Equivalent make of required specification to be approved by the Engineer In charge) |
| 37 | Supplying and fixing brass batten/Angle holder including connection etc. as required. (Make Havells/ HPL / Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge) |
| 38 | Supplying and fixing 3 pin, 5 A Ceiling Rose on the existing junction box/wooden block including connection etc. as required. (Make Havells/ Anchor / Sanchi Major Equivalent make of required specification to be approved by the Engineer In charge) |
| 39 | Providing and fixing following rating and breaking capacity MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Make Anchor /Havells /HPL Equivalent make of required specification to be approved by the Engineer In charge) i. 100 AMP 16kA TP MCCB |
| 40 | ii. 200 AMP 25kA TPMCCB |
| 41 | iii. 315 AMP 35kA TPMCCB |
| 42 | iv. 200 AMP 36kA FPMCCB |
| 43 | Laying of one number PVC Insulated and PVC sheathed/XLPE power cable 1.1 KV grade of following size cables direct in ground including excavation and refilling the trench etc as required but excluding sand cushioning and protective covering.UPTO 35 sq mm |
| 44 | Supply and drawing co-axial TV cable RG-6 grade,0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/Recessed steel/PVC conduit as Reqd. (Make ANCHOR/HPL/HAVELLS/C&S Equivalent make of required specification to be approved by the Engineer In charge) |
| 45 | Re-wiring for light point/fan point/call bell point exhaust fan point with 1.5 Sqm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. (Wire Make ISI Marked Havells/Anchor/KEI/Polycab )(Conduit Make - ISI Marked Anchor/High Power /AKG Equivalent make of required specification to be approved by the Engineer In charge) i.Group ‘A’ |
| 46 | ii.Group ‘B’ |
| 47 | Supplying and fixing of following ratings and poles 240/415 volts Isolators in the existing MCB DB complete with connections, testing and commissioning etc. as required (Make Havells /Legrand /Anchor/ C&S/L&T/ Siemen/IA/HPL/Standard Equivalent make of required specification to be approved by the Engineer In charge) a.40 Amp 240 volt Double Pole. |
| 48 | b.63 Amp 240 volt Double Pole Isolator. |
| 49 | c.63 Amp 415 volt Four Pole Isolator. |
| 50 | Supplying and drawing of following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required(Wire Make ISI Marked Havells/HPL/Anchor/KEI/Plaza/Polycab Equivalent make of required specification to be approved by the Engineer In charge) i.1x1.5 sq mm |
| 51 | ii.3x1.5 sq mm |
| 52 | iii. 3x2.5 sq mm |
| 53 | iv.2x6 sq mm |
| 54 | v.4x4 sq mm |
| 55 | vi.4x6sq mm |
| 56 | P/F M.V danger notice plate of (200x150) mm made of mild steel at least 2mm thick and vitreous enameled white on both side and with inscription in single red colour on front side as reqd. |
| 57 | Supply and drawing UTP 4 Pair Cat 6 LAN Cable in the existing surface/recessed steel/PVC conduit as required (Make Legrand /Havells / Anchor/D Link /HPL/L&T Equivalent make of required specification to be approved by the Engineer In charge)1 run of cable |
| 58 | Non-Schedule Items Supply &Installation of following type of surface mounted/recessed mounted decorative Indoor Linear energy saving , energy efficient LED Lumainiers complete with connection testing and commissioning. Make (Halonix/ Havells/Bajaj/HPL/Compact) Equivalent make of required specification to be approved by the Engineer In charge) 4 feet 18 to 22 watt ,230 volts LED batten type tube light fitting complete . |
| 59 | 2 feet 9 to 12 watt ,230 volts LED batten type tube light fitting complete |
| 60 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K(As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)18-22 watt |
| 61 | 24-26 Watt |
| 62 | 8.6 LED Panel light 2x2 ft. (System lumen efficacy ≥105<120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 63 | 8.14 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacSupplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (Asper ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. 50 watt |
| 64 | 50 Watt (Flood Light) |
| 65 | 100 watt (Flood Light) |
| 66 | 100 watt (Street Light) |
| 67 | Design, manufacture, testing at works & supply, installation, testing & commissioning cubicle panel floor mounted (on base frame) totally enclosed and extensible type . The general construction shall comprise to IS 8623-93. The design shall include all provisions for safety of operating and maintenance personal. IP 42 for indoor and IP54 for outdoor, shall be compartmentalized type having space and arrangements for I/C. cable/bus ducting/incoming switch gears, bus couplers, insulated and properly supported compartmentalized switch gear, outgoing compartmentalized switch gear, bus bar support and terminations, interconnection between bus bars & switch gear with auxiliary bus bars/ insulated conductors/strips etc. (Make Electric Field/ Bharti Engineers/Gupta & Friends/ Jai maa/KED)MAIN OUTDOOR /BUILDING CONTROL PANEL a. INCOMING Space for 1 to 2 No. 200 to 630 Amp TPN Al. Bus bar of equal cross section for Main Power connection to Main MCCB.Space for 1 No. 200 to 630 Amp 4 pole MCCB of 35 KASpace for 1 no. 3-phase 5-wire Progdy type electronic meter.b. INDICATING PANEL The indicating panel of the incomer shall be provided with the following:i. Ammeter of required range with ASS, CT's.ii.Voltmeter of required range with VSS.c. OUTGOINGSpace for 1 No. 200 to 630 Amp TPN Al. Bus bar of equal cross section for power load/light load.Dimensions2’x2’x1’6” |
| 68 | MAIN NORMAL CUM EMRENGECYa. INCOMING Space for 1to2 No. 100-630 Amp MCCB 35 KAb. INDICATING PANELThe indicating panel of the incomer shall be provided with the following:i. Ammeter of required range with ASS, CT's.ii.Voltmeter of required range with VSS.c. BUS BARSpace for 1 No. 100-630 Amp TPN Al. Bus bar of equal cross section for power load.d. OUTGOINGSpace for 2 to 4 No. 63-200Amp 4 pole MCCB Dimensions3’x 2 x 1’6” |
| 69 | Supply, testing and commissioning and Laying of PVC sheathed Aluminum conductor 1100 volts graded PVC AA Armoured/unarmoured XLPE Cable including end termination, crimping, cost of thimbles, nuts bolts, glands, connection, testing and commissioning complete job. (Make: Havells / General/Polycab / Gloster) Equivalent make of required specification to be approved by the Engineer In charge) 2 core 16 sq mm armoured cable |
| 70 | 3 ½ core 120 sq mm armoured cable |
| 71 | 3 ½ core 185 sq mm armoured cable |
| 72 | 4 ½ core 95 sq mm armoured cable |
| 73 | 2 core 16 sq mm Flat cable |
| 74 | Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 1 star rated energy efficient .(Make of required specification to be approved by the Engineer In charge) |
| 75 | Supply, installation, testing, commissioning of 1200 mm sweep ceiling fans complete with blades BEE 3 star rated energy efficient .(Make: Havells /Anchor/USHA /Crompton) Equivalent make of required specification to be approved by the Engineer In charge) |
| 76 | Supply /Installation testing and commissioning of 450 mm sweep wall mounted fan including the electronic regulators and connection with testing and commissioning etc complete Job BEE 1 star rated energy efficient. Make: (Anchor /Bajaj /Cromton/ Havells Equivalent make of required specification to be approved by the Engineer In charge ) |
| 77 | Supply, installation, testing, commissioning of 300 mm sweep BEE 1 star rated energy efficient exhaust fan. Make: ( Anchor/Havellls/Bajaj/Crompton Equivalent make of required specification to be approved by the Engineer In charge) |
| 78 | Supply & installation of CAT 6 2 module toll less information outlets complying fully or exceeding with category 6 connecting hardware specifications for all pair combinations upto 250 MHz. Outlets shall use lead frame technology, non PCB pyramid type complete as required.(Make Legrand/Delton/Havells/HPL/Anchor) |
| 79 | Supply and installation of Singlex Face Plates along with clearly printed labels and holders complete as required(Make Legrand /Havells / Anchor/D Link /HPL) |
| 80 | S/F of 32mm dia G.I pipe for flood light bracket including bending to shape, (40x3)mm flat iron clamp and wiring with 1.5 sqmm PVC insulated wire complete wire complete as reqd. |
| 81 | P/F following rating 230 volts energy saver LED Lamps (Make :Philip /Havells/Bajaj/ Surya/ Crompton/Compact/Halonix Equivalent make of required specification to be approved by the Engineer In charge)i.8 to12 watt LED |
| 82 | ii. 10 to 15 Watt LED Charging Lamp |
| 83 | iii. 40 to 50 W LED Lamp |
| 84 | Supplying and fixing bus bar chamber with 4 strips bus bar of following size, made of the copper, suitable for following capacity complete with all accessories including connections, earthing the body as required. 450mm 100 Amp |
| 85 | 450mm 200 Amp |
| 86 | Providing/fixing following way PVC gang box suitable for following socket and switches. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge)i.3 pin 5 Amp socket with switch |
| 87 | ii.6 pin 15 amp socket with switch |
| 88 | Supplying and fixing following ways horizontal type MCB Distribution Board 230V on surface/in recess complete interconnections including powder painted etc. as required IP 43 IK 09 (But without MCB/SPN.) i.4 way Encloser For A.C Havells/Anchor /I.A /HPL/ Equivalent make of required specification to be approved by the Engineer In charge |
| 89 | Providing/fixing 32 to 40 amp rating , 230 volts SPN MCB with breaking capacity of 10kA in the existing MCB DB or enclose complete with connection testing and commissing complete Job. (Havells/Anchor/HPL make Equivalent make of required specification to be approved by the Engineer In charge) |
| 90 | Providing/fixing Ding Dong wall bell including connection as required (Anchor/HPL/Klick Equivalent make of required specification to be approved by the Engineer In charge) |
| 91 | Providing/fixing following rating plug tops (Anchor/Sanchi major/HPL make) i.3 pin 5 Amp |
| 92 | ii.3 pin 15 Amp |
| 93 | P/F of 3mm thick phenolic laminated sheets of following size.Crown /Hylam. 5’’x5’’ |
| 94 | 9’’x6’’ |
| 95 | 11’’x13’’ |
| 96 | 3’’ Round |
| 97 | 5’’ Round |
| 98 | P/laying of 100 mm dia heavy duty PVC pipe in ground including digging the pit and refilling complete job. (prince/supreme/Uniplas) |
| 99 | Supply and fixing of following rating onload I-O-II Four pole with advanced neutral on load change over switch confirms to IS 13947 (Part-3) IEC:609473) (Make I.A/Havells/HPL/Crompton Equivalent make of required specification to be approved by the Engineer In charge)100 Amp |
| 100 | 200Amp |
| 101 | 315Amp |
| 102 | Supply and fixing of (75X75)mm press fit type PVC Trunking for drawing the electric wires/Cables. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysSep 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender