Tender For Comprehensive Maintenance Of Army Aviation Assets At Kumbhigram Af Stn And Maint/ Repair Of Summer And Colling Appliances At Masimpur Mil Stn Incl Army Est At Kumbhigram And Silchar Under Masimpur Mil Stn
Tender Value
27.10 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
14 days left
EMD
54200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cachar → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Maintenance Of Army Aviation Assets At Kumbhigram Af Stn And Maint/ Repair Of Summer And Colling Appliances At Masimpur Mil Stn Incl Army Est At Kumbhigram And Silchar Under Masimpur Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) and removal of debris complete all as specified and as directed. |
| 3 | Demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles and disposing off complete all as specified and as directed. |
| 4 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed. |
| 5 | Dismantling mild steel work or wrought iron of any description and in any position complete all as specified and as directed. |
| 6 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 7 | Dismantling wall and ceiling boards (AC,fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets, frameworks, etc. complete all as specified and as directed. |
| 8 | Dismantling asbestos cement pipe/ rain water pipe/sewage line pipe of any type and any size including fitting, clamp complete all as specified and as directed. |
| 9 | Taking down cement or cement/lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for keys, scubbing down with water, etc. including all necessary scaffolding as required and rubbishing off the premises, etc. complete all as specified and as directed. |
| 10 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 11 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each exceeding 1.50 Sqm but not exe 4 Sq cm each complete all as specified. |
| 12 | Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 13 | M&L for providing 75 mm thick cement concrete (1:4:8) type D-2 using (40mm graded stone aggregate) as in Sub base of floor rough surface for receiving tile complete all as specified. |
| 14 | M&L for 75mm thick cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection finished even and fair without using extra cement laid in panels and joints filled with bituminous mastic filling with 1 part of bitumen and 3 part of sand complete all as specified and directed. |
| 15 | M & L for plain cement concrete (1:2:4) type B1 using 20mm graded aggreagate as in lintels upto 1.50m clear span, bed blocks, coping , cills, steps, kneelers, bed plates, apex stones kerbs and similar works including necessary formwork complete all as specified and directed. |
| 16 | M&L brick work with sub class ‘B’ brick straight or curved on plan exe. 6 meters mean redius built in cement mortar 1:6 complete all as specified and as directed. |
| 17 | M&L brick work with sub class ‘B’ brick straight or curved on plan to any radius in half brick wall in cement mortar 1:4 complete all as specified and as directed. |
| 18 | M & L rendering 10mm thick in cement mortar 1:6 on any faces of brick wall or concrete surfaces, finished even and smooth without using extra cement complete all as specified. |
| 19 | M & L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on any faces of brick wall or concrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished even and smooth without using extra cement complete all as specified. (Note :WPC measured separately). |
| 20 | Supply only integral water proofing compound all as specified. (for item No 85 & 151 ) |
| 21 | M & L Non Skid ceramic tiles colour 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 20 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry complete all as specified. |
| 22 | Material and labour Non-skid coloured ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqm as in floors set and jointed in cement slurry and pointed in white or colour cement to match the shade of tile over and including screed bed or bedding layers of 15 mm thick cement mortar (1:4) complete all as specified |
| 23 | Material and labour Non-skid coloured ceramic tiles 7 to 8 mm thick ( square/rectangular) area of each tiles exc 0.18 sqm but not exc 0.38 sqm as in vertical surfaces of skirting/bdado etc over 10 mm thick rendering in cm (1:4) complete all as specified. |
| 24 | M&L of Glazed ceramic coloured tiles in vertical surface size 450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed. |
| 25 | Supply and fix pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 26 | Supply and fix pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 27 | S&F Framed work such as grills, gratings, etc., with ends of bars shouldered and or riveted, or forged in to spikes; framed guard bars; similar work conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 28 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 125x60mm for door and window frames with one or more rebates including hinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 29 | S & F Pressed steel frames made of 1.25mm thick MS sheet of profile 105x60mm for door and window frames with one or more rebates including hinges (100/50mm stainless steel),lock strike plate, shock absorber, 20mm dia 60mm long MS conduit for housing of a drop bolt, treating of internal surfaces of chowkhats with coal tar or black paint including hinges, hold fasts/lugs etc complete all as specified. |
| 30 | M&L for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregates) as in back filling of pressed hallow steel frame and holdfasts, etc. including necessary formwork complete all as specified and as directed. |
| 31 | S&F Steel windows with side hung shutters including box type hinges with steel handles, 100mm long peg stay complete with glazing bars, dovetailed or welded, including locking arrangements complete all as specified directed. |
| 32 | S & F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides , smooth finish with lipping of teak wood on edges all as specified and directed. |
| 33 | Material and labour Second class hard wood as in 35 mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified & directed . |
| 34 | Supply and fix Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and directed. |
| 35 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified. |
| 36 | Supply & Fixed Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm all as directed and specified. |
| 37 | S&F 3.00 mm thick sheet glass ordinary quality and glazing with oil putting square nexc 0.5 sqm in each pane complete all as specified and directed. |
| 38 | Supply and fix 150 mm long aluminium handles cast type anodised complete all as specified & directed . |
| 39 | Supply and fix 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 40 | S&F 300 mm length of Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified. |
| 41 | Supply and fix, as in repair, vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified. |
| 42 | Supply & Fixed in repairs Vitreous china wash down water closet pan ( pedestal pattern ) , white with P or S trap incl. seat cover but excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. |
| 43 | S & F in repairs PVC valveless, syphonic action type,low level PVC flushing cistren 10 ltr cap white with flush pipe &all fitting and flush pipe complete all as specified. |
| 44 | S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 45 | S & F in repair, soap dish chromium plated standerd quality fixed on wall with brass screw complete all as specified. |
| 46 | Supply and fix as in repair 15 mm bore pillar tap fancy type , cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe complete all as specified. |
| 47 | Supply and fix, as in repair, 15 mm bore bib taps fancy type ,chromium plated, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified. |
| 48 | Supply and fix, as in repair, angle stop valve fancy type , cast copper alloy,chromium plated ,screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions all as specified. |
| 49 | Supply and fix, as in repairs, 32 mm dia and 800mm long PVC flexible corrugated waste pipe for wash basin/sink complete all as specified and as directed.Make: Prayag CAT No. 327 or equivalent as per approved product list |
| 50 | Supply and fix in repair Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified. |
| 51 | S & F as in repair bevelled edge mirror complete all as specified and directed.Make : Modiguard, Saint Gobain or equivalent |
| 52 | S&F 75mm dia PVC (SWR) pipes single socketed, in any length fixed to walls / floors or in trenches complete all as specified. |
| 53 | Supply & Fixed in repairs PVC (SWR) bends 75 mm bore any radius complete all as specified. |
| 54 | S&F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed. |
| 55 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid all as specified and directed. Make:Everest Industries Ltd or equivalent as per IS 14862. |
| 56 | Material and labour for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified and directed. |
| 57 | M&L for prepration of new or previously untreated surface and applying two coat of oil bound distemper over a coat of primer on wall complete all as specified and directed. |
| 58 | Material & Labour for preparation of new or previously untreated wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified. |
| 59 | M&L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 60 | M&L preparation of old steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 61 | M&L preparation of new wood or wood base surface of any description over 10cm width or girth applying two coats of synthetic enameled paint over one coat of pink primer complete all as specified. |
| 62 | E & M Division items |
| 63 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. |
| 64 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 65 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 66 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch 5 Amp. |
| 67 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 68 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 69 | M & L for point wiring with FRLS stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 70 | M & L for point wiring with FRLSH stranded copper conductor 4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Casing caping including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one power point on independent board of AC/equipments etc controlled by one SP/SPN MCB. Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 71 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 72 | S&F switch piano flush type button single pole one way 5 Amps with cover plate all as specified and directed. |
| 73 | S&F socket outlet 3/5 pin 5 Amps flush type with cover plate all as specified and directed. |
| 74 | S&F switch socket outlet 3 pin 15 Amps 2 in 1 universal with cover plate all as specified and directed |
| 75 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts AC supply complete with cover plate all as specified. |
| 76 | S&F lamp Angular holder insulated body with back plate suitable for batten fittings all as specified and directed. |
| 77 | M&L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including heavy duty PVC casing caping with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Casing caping will be measured as one length. |
| 78 | M&L for submain wiring with two single core 6.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including heavy duty PVC casing caping with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 6.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Casing caping will be measured as one length. |
| 79 | Taking down old serviceable tube light fittings 1 X 22 watt or any capacity, batten type from existing location and refixing in new / existing location after completion of civil work complete all as specified and directed. |
| 80 | S&F 600 x 600 mm LED type down lighter 36 watt complete with drivers connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. |
| 81 | S&F wall mounted, compact LED batten 20 watt and connecting with three core flexible copper conductor cable of suitable size from ceiling rose including taking down of old unserviceable one complete all as specified and directed |
| 82 | S&F wall mounted, compact LED batten 10 watt and connecting with three core flexible copper conductor cable of suitable size from ceiling rose including taking down of old unserviceable one complete all as specified and directed |
| 83 | S&F 10 watt wall mounted bulk head fittings, complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V , 50Hz complete all as specified and directed. |
| 84 | S&F LED bulb inverter 10 watt, retrofit type works on AC normal mode & DC in inverter mode with efficiency lumens output connecting to lamp holder complete all as specified and directed.Make - Crompton Cat Part No LSL-6-WW or equivalent as per approved product list. |
| 85 | S&F bldg security light, LED luminaire 30 watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. |
| 86 | S&F Angle bracket 40mm dia for fixing building security light of 40mm dia of 1 mtr long bent to shape 45 degree for fixing of security light including MS clamps of suitable size including nuts, bolts complete all as specified and directed |
| 87 | S & F in repair plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed. |
| 88 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 89 | S&F in repairs Metal Plug and socket with MCB SP 20 amp 240 V enclosure for AC / equipment with neutral and Earth point all as specified and directed. |
| 90 | S&F Factory made distribution board sheet metal enclosure powder coated single phase and neutral (SPN) DB for fixing of MCBs, 8 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 91 | S&F Factory made distribution board sheet metal enclosure powder coated triple phase and neutral (TPN) double door DB for fixing of MCBs, 4 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 92 | S&F MCB TPN capacity 63 Amps 240 volts, 50 Hz C- Curve complete all as specified and directed |
| 93 | S&F MCB SPN capacity 40 Amps 240 volts, C- Curve 50 Hz complete all as specified and directed |
| 94 | S&F MCB SP capacity 6-32 Amp 240 volts, C - Curve 50 Hz complete all as specified and directed |
| 95 | M&L in replacement for earthing with galvanised steel earth plate electrode 600mmX600mmX6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. |
| 96 | Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 10 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old UNSV wire all as specified and directed. |
| 97 | REPAIR/MAINTENANCE OF AIR CONDITIONER |
| 98 | M & L Removing from existing position, AC unit of Window type AC 1.5/2.0 ton capacity of any make and Servicing of following air conditioners 1.5/2 ton window/ split type in position or at workshop comprising of cleaning , free from dust / cleaning the evaporator , air filter ,condenser coil with cleaning agent and water Service , tightening all electrical contaacts, bolts , nuts ,etc .greasing / oiling blower motor assy, testing the serviceability of rubber bushes , connector , clips , bolts , nuts , washers etc, including checking the compressor unit complete all as directed. |
| 99 | M & L Removing from existing position, AC unit of Split AC 1.5/2.0 ton capacity of any make and Servicing of following air conditioners 1.5/2 ton window/ split type in position or at workshop comprising of cleaning , free from dust / cleaning the evaporator , air filter ,condenser coil with cleaning agent and water Service , tightening all electrical contaacts, bolts , nuts ,etc .greasing / oiling blower motor assy, testing the serviceability of rubber bushes , connector , clips , bolts , nuts , washers etc, including checking the compressor unit complete all as directed. |
| 100 | Attending complaint for non-functioning of air condiotioner at UVA Kumbigaram and Masimpur stn at any time and rectifying the complaint on urgent nature upto satisfaction of user by repairing, replacing UNSV parts, electric wire, etc. Note:- (a) Spare part shall be measured and paid separately for relevant items of schedule. (b) Complaint shall be attended and rectified within 24 hrs by the contractor. Suitable penalty will be recovered from the contractor if the complaint is rectified after 24 hrs. (c) Gas charging and servicing will not be measured in the complaint. |
| 101 | Supply and fix in repairs Sealed Unit (Compressor) for Air Conditioner of Cap 2 ton capacity including preparation for fixing new Compressor to Old Unit complete all as specified and directed by Engr-in-charge.(Make-CARRIER/LG/HITACHI/HIGHLY) |
| 102 | Supply and fix in repairs Sealed Unit (Compressor) for Air Conditioner of Cap 1.5ton capacity including preparation for fixing new Compressor to Old Unit complete all as specified and directed by Engr-in-charge.(Make-CARRIER/LG/HITACHI/HIGHLY) |
| 103 | Material and labour for Gas Charging with Refrigerant R-22/R- 134A and get back required quantity pressure to any make /model of AC including leak testing after and before Gas Charging complete of air conditioner all as specified and directed by Engr-ic-charge. |
| 104 | Supply and fix in repairs Condensing Coil Assembly of Air Conditioner of any make, including necessary fittings such as Clamps, Nuts , Bolts, Soldering, bracing complete as in repair all as specified and directed by Engr-in-charge. |
| 105 | Taking out the defective Items and Supplying and fixing of item Thermostart switch with regulating knob as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 106 | Taking out the defective Items and Supplying and fixing of item Starting Capacitor 80/100/120 MFd as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 107 | Taking out the defective Items and Supplying and fixing of item Blower motor 8 Mfd Capacitor as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 108 | Taking out the defective Items and Supplying and fixing of item Running Capacitor of Capacity 36 Mfd as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 109 | Taking out the defective Items and Supplying and fixing of item Running Capacitor of Capacity 50 Mfd as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 110 | Taking out the defective Items and Supplying and fixing of item Relay Box Type/Open Type as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 111 | Taking out the defective Items and Supplying and fixing of item Selector Switch with Knob as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 112 | Taking out the defective Items and Supplying and fixing of item Overload Protector Relay as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 113 | Taking out the defective Items and Supplying and fixing of item Remote control hand set for Air conditionere as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 114 | Taking out the defective Items and Supplying and fixing of item Front grill suitable as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. . |
| 115 | Taking out the defective Items and Supplying and fixing of item Air filter for Window/Split AC as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 116 | Taking out the defective Items and Supplying and fixing of item Remote control PCB Circuit for Air conditioner as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 117 | Taking out the defective Items and Supplying and fixing of item Capillary Charging as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 118 | Taking out the defective Items and Supplying and fixing of item MS stand for split AC as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 119 | Taking out the defective Items and Supplying and fixing of item Drain pipe 15 mm dia of 3 mtr long as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 120 | Taking out the defective Items and Supplying and fixing of item Blower fan Motor for Split Air conditioner as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 121 | Taking out the defective Items and Supplying and fixing of item Blower fan Motor for Split Window AC as per exsiting on ground for 1.5 Ton/2 Ton Air Conditioner complete all as directed by Engineer - in -Charge. |
| 122 | REPAIR/MAINTENANCE OF WATER COOLER |
| 123 | M & L for removing water cooler from existing position after disconnecting from inlet water connection and plugged the water line and Servicing of Water cooler of any capacity in position or at repair work shop comprising of cleaning to free from dust /cleaning the evaporator,condenser coil with cleaning agent ,cleaning of water tank ,servicing of water float valve and ,tightening , all electrical contacts, bolts ,nuts, checking of compressor unit all as directed. |
| 124 | Supply and fix Sealed in repairs Unit Compressor for Water Cooler of Cap 60/120 ltr including preparation for fixing new Compressor to Old Unit complete all as specified and directed by Engr-in-charge.(Make-AS per site) |
| 125 | Material and labour for Gas Charging with suitable refrigerant R-22/R- 134A to get required back pressure and cooling to any make/model for water cooler as specified and directed by Engr-in-charge. |
| 126 | Supply and Fix in repairs Blower Motor Assembly of Water Cooler of Existing Model/Type including nuts, bolts, Clamps etc all complete as directed by Engr-in-charge. |
| 127 | Supply and fix Condensing Coil in repairs Assembly to Water Cooler including connection clamps, nuts, bolts etc complete all as directed by Engr-in-charge. |
| 128 | Supply and fix, replacement of Starting Capacitor 60-80mFd for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 129 | Supply and fix, replacement of Running Capacitor of rating 25 mfd for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 130 | Supply and fix, replacement of Thermostatic Switch with Regulating Knob for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 131 | Supply and fix, replacement of Push Cock, self closing chromium plate 15mm bore including nut and washer etc for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 132 | Supply and fix, replacement of PVC drain pipe 1 mtr long including clamps for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 133 | Supply and fix, replacement of Float Valve of Gun metel, 15 mm bore with ball and rod for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 134 | Supply and fix, replacement of Over load protector relay for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 135 | Supply and fix, replacement of Running Capacitor 36 mfd for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 136 | Supply and fix, replacement of Pencil stainer for water cooler for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 137 | Supply and fix, replacement of Water Tap with 6'' concealed end pipe of size 15MM for 40/80,60,120,150 Ltr Capacity water Cooler complete all as directed by Engr-in-charge. |
| 138 | REPAIR/MAINTENANCE OF REFRIGERATORS/DEEP FREEZERS |
| 139 | Servicing of Refrigerator of any capacity in position or at repair work shop comprising of cleaning to free from dust / cleaning the evaporator,condenser coil with cleaning agent ,cleaning of water tank ,servicing of water flot valve and ,tightening all electrical contacts,bolts ,nuts etc.Checking of Compressor Unit.Complete all as directed by Engineer in charge. |
| 140 | Supply and fix in repairs Sealed Unit (Compressor) of Refrigerator Capacity 165 to 310 Ltr, including preparation for fixing new Compressor to Old Unit complete all as specified and directed by Engr-in-charge.(Make-Whirpool/God rej/Zenith) |
| 141 | Material and labour for Gas Charging of Refrigerator with Refrigerant R-22/R134-A of suitable quantity to get required back pressure and cooling effect complete all as directed and specified by Engr-in-charge. |
| 142 | Supply and fix in replacement of Relay Open type (Over load cum Relay) for refrigerator complete all as directed and specified by Engr-in-charge. |
| 143 | Supply and fix in replacement of Overload protector suitable for Refrigerator for refrigerator complete all as directed and specified by Engr-in-charge. |
| 144 | Supply and fix in replacement of Cooling coil door with locking spring etc.for refrigerator complete all as directed and specified by Engr-in-charge. |
| 145 | Supply and fix in replacement of Thermostart switch with regulating knob etc for refrigerator complete all as directed and specified by Engr-in-charge. |
| 146 | Supply and fix in replacement of Fan motor/evaburator for refrigerator complete all as directed and specified by Engr-in-charge. |
| 147 | Supply and fix in replacement of Fan blade for refrigerator complete all as directed and specified by Engr-in-charge. |
| 148 | Supply and fix in replacement of Chiller tray as per existing model for refrigerator complete all as directed and specified by Engr-in-charge. |
| 149 | Supply and fix in replacement of Frost free timer for regrigerator for refrigerator complete all as directed and specified by Engr-in-charge. |
| 150 | Supply and fix in replacement of Frost free cooling coil for refrigerator complete all as directed and specified by Engr-in-charge. |
| 151 | Supply and fix in replacement of Capillary Charging for refrigerator complete all as directed and specified by Engr-in-charge. |
| 152 | Supply and fix in replacement of Thermal fuse for refrigerator complete all as directed and specified by Engr-in-charge. |
| 153 | Supply and fix in replacement of LED lamp bulb freezer fridge mini 2 Watt 220 Volt for refrigerator complete all as directed and specified by Engr-in-charge. |
| 154 | Taking out carefully existing defective sealed unit compressor Supply & fixing factory made rotary type sealed compressor unit same as per existing model and make suitable for deep freezer 200/300 ltrs including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. |
| 155 | S&F as in repairs capillary tube and silica drier type strainer suitable for deep freezer 200/300/345/400 ltrs capacity all as specified. Make: RAPID CONTROL/SANT/AIP/SIR. |
| 156 | S&F as in repairs starting capacitor 4/6/8 mfd as per requirement at site for deep freezer of capacity 200/300/345/400 ltrs complete all as specified. Make: TESLA/EPCOS/SIEMENS/USHA. |
| 157 | S&F as in repairs over load protector relay suitable for deep freezer 200/300/362 ltrs capacity complete all as specified. Make: SHRIRAM/RENUTROL/DANFOSS. |
| 158 | S&F as in repairs thermostat switch suitable for deep freezer 200/300/362 ltrs capacity complete all as specified. Make: RENUTROL/DANFOSS/INDFOSS. |
| 159 | S&F as in repairs relay open type suitable for deep freezer 200/300/362 ltrs capacity complete all as specified. Make: SHRIRAM/RENUTROL |
| 160 | S&F as in repairs fan motor suitable for deep freezer 200/300/362 ltrs capacity complete all as specified. |
| 161 | M&L for gas changing of deep freezer with refrigerant R22/R134A of suitable quantity to get back required pressure and effect including leak testing after and before gas charging complete all as specified. |
| 162 | Repairs to voltage stabilizer 4/5 KVA of different make including replacement of worn out parts as volt meter, transformer, circuit plate, step-up, step-down relay etc all as specified. |
| 163 | S&F in repair single pole and neutral sheet metal enclosure powder coated with a two pin and earth plug and socket complete with 20 Amp single pole MCB and making good disturbed surface completed all as specified and directed. |
| 164 | Material and labour for shifting of A/C window type or split type A/C, tower AC of capacity 1.5/2/2.5 TR with mounting bracket including washing cooling coil/condensor coil base body drying with air blower complete all as specified and directed. |
| 165 | Supply and fix in repairs hi- wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of capacity 2 TR electric driven single phase 230 Volt complete all as specified and directed. |
| 166 | Supply and fix in repairs hi- wall split units indoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality including taking down old u/s indoor AC unit of 1.5 TR capacity electric driven single phase 230 Volt complete all as specified and directed.-ditto- all as per item No 29 above but for complete all as specified and directed. |
| 167 | Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 2 TR including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed. |
| 168 | Supply and fix in repairs hi wall split units outdoor (Condener unit) of capacity 1.5 TR including filling of refrigerant including taking down old u/s outdoor AC unit complete all as specified and directed. |
| 169 | Supply only in repairs cordless remote control unit suitable for capacity of 2 / 1.5 Ton suitable for window/ Split AC complete all as specified and directed. |
| 170 | M&L for point wiring with FRLS 4.0 sqmm multi-strand PVC insulated and unsheathed copper conductor drawn in through casing caping on surface with all accessories such as saddles, crews, plastic guties, etc fixed to wall/roofs/ceiling etc on surface and incl provision of cable 2.5 sqmm PVC insulated unsheathed multistranded copper conductor to common earth conductor as earth continuity conductor connected to earth dolly in and including 1.60 mm thick pressed steel concealed terminal boxes and with top cover 3 mm thick ISI marked plastic laminated hylum sheet top cover for mounting the switches, socket outlets, fan regulators etc of reqd colour fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat red oxide primer complete with all accessories and all as specified and directed. |
| 171 | M & L for submain wiring with approved colour coding as per IS with four single core FRLSH PVC insulated cable with stranded copper conductor of size 6.0 Sqmm nominal area and drawing into PVC non metallic rigid PVC casing including one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor as earth wire complete all as specified and as directed.Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC casing caping will be measured as one unit |
| 172 | Taking out old defective MCB & Supplying and fixing new MCB, SP, 6 to 32 Amps, 240 Volts , 10 KA complete including connecting all as directed by Engineer - in - Charge. |
| 173 | S&F as in repairs, 3 pin plug top 5 Amp complete all as specified and directed by Engineer - in - Charge. |
| 174 | S&F as in repairs, 3 pin plug top 15 Amp complete all as specified and directed by Engineer - in - Charge. |
| 175 | Supply and fix in replacement copper tube with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge of size 6mm bore including brazing etc |
| 176 | Supply and fix in replacement copper tube 10mm bore icl brazing with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge |
| 177 | Supply and fix 3 core flexible cable PVC insulated sheathed copper 1100 volts grade 2.5 Sqmm complete all as specified and as directed.Make -Plaza/HavellsPolycab /Finolex |
| 178 | S&F as in repairs, wall mounted voltage stabilizer of capacity 5.0 KVA for automatic operation, single phase naturallyair cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer