Tender For Special Repair Of All Pipe Lines And Allied Parts Of Chs Plant No 4 & 5 At Transit C Under Ge 865 Ews, Leh
Tender Value
1.43 Crore
Estimated cost
Bid Submission
10 Oct 2026
6 days left
EMD
2.18 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair Of All Pipe Lines And Allied Parts Of Chs Plant No 4 & 5 At Transit C Under Ge 865 Ews, Leh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Sep-2026 | REVISION OF BOQ | BOQ | 10-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | BOILER (Hot Water Suply Plant). Dismantling of burner assembly installed at Transit Camp and removing of side cover and repairing the same by removing the old burnt fire refractory cement plastering, replastering the same as per existing with fire refractory cement for boiler capacity upto 4 lakh kilo/cal/hr and complete servicing the boiler by removing the complete carbon/oil deposits with suitable coil shine chemical including repair to coil assembly by welding if there is any leakage found or any other repair required at site and reassembling/ testing the same, complete all as specified and/or as directed by Engr-in Charge. |
| 2 | Dismantling of boiler capacity 3 to 4 lakh kilo/cal/hr disconnecting all electric/fuel/water connection of unsv glycol tubing to isolate combustion chamber of boiler and with help of tripod and chain pully without damaging internal chamber and supply and fix of boiler coil for 3 to 4 lakh kilo/cal/hr capacity Central Heating Plant as per existing shape size & dimension as per manufacturer's recommendations, complete all as specified and/or as directed by Engr-in Charge. Make : Aquatherm/ Themax or equivalent as approved by GE. |
| 3 | S&F in sequence controller suitable for 3 to 4 lakh kilo/hr with burner rod assembly, as per existing model, complete all as specified and/or as directed by Engr-in Charge. Make- Siemens. |
| 4 | S&F in replacement of ignition rod suitable for 3 to 4 lakh kilo/Cal/hr burner rod assembly,as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 5 | S&F in replacement of ignition transformer electronic type suitable for 3 to 4 lakh kilo/Cal/hr burner rod assembly as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 6 | S&F temp controller digital type DTC 503 with sensor suitable for 3 to 4 lakh kilo/cal/hr LAL 2.25 burner rod assembly as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 7 | S&F in replacement of pressure gauge 0 to 10.6 Kg/sqcm as per existing model,complete all as specified and/or as directed by Engr-in Charge. |
| 8 | S&F in replacement of photo cell suitable for 3 to 4 lakh kilo/cal/hr burner rod assembly as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 9 | S&F in replacement of burner nozzle suitable for 3 to 4 lakh kilo/cal/hr as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 10 | S&F in replacement of Electrode suitable for burner of capacity 3-4 lakh kilo/cal/hr as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 11 | S&F in replacement of bridge rectifire for burner of capacity 3-4 lakh kilo/cal/hr as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 12 | S&F in replacement of hooter round type for burner of capacity 3-4 lakh kilo/cal/hr as per existing model, complete all as specified and/or as directed by Engr-in Charge. |
| 13 | S&F in replacement of thermostat assembly tail type suitable for 0-70 degree centrigrade temprature, complete all as specified and/or as directed by Engr-in Charge. Make- Honeywell. |
| 14 | S&F in replacement of oil pressure pump 7276-3D67A as per existing model, complete all as specified and/or as directed by Engr-in Charge.Make- Suntec. |
| 15 | S&F in replacement of fuel filter 1/2 ltr as per existing model, complete all as specified and/or as directed by Engr-in Charge.Make- Kirloskar/Mico/TVS. |
| 16 | S&F in replacement of auto air pressure valve 3/8\\" as per existing, complete all as specified and/or as directed by Engr-in Charge. |
| 17 | S&F in replacement of high pressure fuel pipe 1.5 mtr as per existing, complete all as specified and/or as directed by Engr-in Charge. |
| 18 | Dismantling old unserviceable diesel burner and supply and fix diesel burner set of capacity 3 to 4 lakh kilo/cal/hr comprising of diffuser, nozzle, electrodes, blast tube, solenoid valve, air damper adjustment, gear pump, coupling set, oil supply pipe, gasket, ignition transformer, reset button, frame detector and controller, complete all as specified and/or as directed by Engr-in Charge. |
| 19 | S&F in replacement of chilled/hot water wall mounting indoor type fan coil unit (FCU) 4500 kilo/cal/hr capacity operated on 230 Volts AC, complete all as specified and/or as directed by Engr-in Charge. |
| 20 | S&F in replacement of chilled/hot water wall mounting indoor type fan coil unit (FCU) 6000 kilo/cal/hr capacity operated on 230 Volts AC, complete all as specified and/or as directed by Engr-in Charge. |
| 21 | M&L for complete cleaning and checking the serviceability of fan coil unit of 3000 to 6000 kilo/cal/hr capacity for having continuous serviceability of FCU for any number of time as desired by Engr-in-Charge including replacement of minor spare parts like gasket, teflon tape, flare nut, tightening of any loose glycol line connections, shifting FCU from one place to another place if required, heating up the freezed glycol line anywhere about the premises and cleaning with the chemical solution by pressure pump from inlet to outlet to have continuous flow of glycol fluid, repairing the insulation of pipe line of any size by providing shallow tape / GI wire as deemed fit, for fastening the insulation with pipe line, stopping any kind of leakage from any size of pipe line, tightening the loose electrical connections as related with FCU / heating system, cleaning the air filter including radiator of FCU to the entire satisfaction of Engineer-in- Charge, complete all as specified and/or as directed by Engr-in Charge. |
| 22 | S&F in replacement of fan coil unit duel shaft electric motor 1/12 HP, 30 watt 930 RPM, 3 speed as per existing, complete all as specified and/or as directed by Engr-in Charge. Make- Maratan/CEG. |
| 23 | S&F in brass nipple threaded size 20 mm for floor mounting FCU to flexible pipe laid in floors or trenches, complete all as specified and/or as directed by Engr-in Charge. |
| 24 | S&F brass tee threaded size for 20 mm for connecting double FCU in flexible pipe to flexible pipe laid in floors or trenches, complete all as specified and/or as directed by Engr-in Charge. |
| 25 | S&F in multi layer composite flexible pipe of FCU connection size 20/16 mm as per existing, complete all as specified and/or as directed by Engr-in Charge.Make- Jindal/Unipro Mecto or equivalent. |
| 26 | Maint. Of Pumps/ motors and Pipe line for supply of Hot Water : M&L for taking out 5HP pumpset and rewinding of electric motor 3 phase 415 volts of capacity 5 HP with superior quality super enamelled copper winding wire of appropriate size and gauge as existing including varnishing, cotton tape, PVC sleeves etc. refixing the same and testing on completion, complete all as specified and/or as directed by Engr-in Charge. |
| 27 | M&L for taking out 3HP pumpset and rewinding of electric motor 3 phase 415 volts of capacity 3 HP with superior quality super enamelled copper winding wire of appropriate size and gauge as existing including varnishing, cotton tape, PVC sleeves etc. refixing the same and testing on completion, complete all as specified and/or as directed by Engr-in Charge. |
| 28 | M&L for taking out 0.5/0.75 HP pumpset and rewinding of electric motor 3 phase 415 volts of capacity 0.5/0.75 HP with superior quality super enamelled copper winding wire of appropriate size and gauge as existing including varnishing, cotton tape, PVC sleeves etc. refixing the same and testing on completion, complete all as specified and/or as directed by Engr-in Charge.Note for Srl item No 26.00, 27.00 & 28.00 : Rewinding the motor with super enamelled copper winding wire temp range 104 degree centigrade to 204 degree centigrade of existing guage including all other insulating material. |
| 29 | Taking down old unserviceable / deteriorated MS pipe from trench/air including connecting accessories of size 50 mm to 150 mm, complete all as specified and/or as directed by Engr-in Charge. |
| 30 | Supply and lay MS pipe heavy grade with all fittings laid in floors or fixed to walls and ceiling etc. of size 150 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 31 | Supply and lay MS pipe heavy grade with all fittings laid in floors or fixed to walls and ceiling etc. of size 100 mm bore, ccomplete all as specified and/or as directed by Engr-in Charge. |
| 32 | Supply and lay MS pipe heavy grade with all fittings laid in floors or fixed to walls and ceiling etc. of size 80 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 33 | Supply and lay MS pipe heavy grade with all fittings laid in floors or fixed to walls and ceiling etc. of size 65 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 34 | Supply and lay MS pipe heavy grade with all fittings laid in floors or fixed to walls and ceiling etc. of size 50 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 35 | S&F in replacement of PP-R pipes PN 20 / SDR 6, 3 layer 40 mm dia bore with all fittings conforming to IS-15801 and fixed to walls and ceiling or laid in floors or trenches, complete all as specified and/or as directed by Engr-in Charge.Make Sant/SFMC or equivalent. |
| 36 | All as per Srl item No 35 above but of 32 mm dia bore. |
| 37 | All as per Srl item No 35 above but 25 mm bore dia. |
| 38 | M&L for insulation of MS pipe with PUF slab 40mm thick with and including applying bituminuous compound and GI cladding with 26 guage GI sheet complete of size 150 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 39 | M&L for insulation of MS pipe with PUF slab 40mm thick with and including applying bituminuous compound and GI cladding with 26 guage GI sheet complete of size 100 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 40 | M&L for insulation of MS pipe with PUF slab 40mm thick with and including applying bituminuous compound and GI cladding with 26 guage GI sheet complete of size 80 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 41 | M&L for insulation of MS pipe with PUF slab 30mm thick with and including applying bituminuous compound and GI cladding with 26 guage GI sheet complete of size 65 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 42 | M&L for insulation of MS pipe with PUF slab 30mm thick with and including applying bituminuous compound and GI cladding with 26 guage GI sheet complete of size 40/50 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 43 | M&L for insulation of MS pipe with PUF slab 30mm thick with and including applying bituminuous compound and GI cladding with 26 guage GI sheet complete of size 32 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 44 | M&L for insulation of MS pipe with PUF slab 30mm thick with and including applying bituminuous compound and GI cladding with 26 guage GI sheet complete of size 25 mm bore, complete all as specified and/or as directed by Engr-in Charge. |
| 45 | S&F in replacement of gun metal butterfly control valves of 100mm bore as per existing, complete all as specified and/or as directed by Engr-in Charge. |
| 46 | Taking down old unserviceable balancing valve and supply and fixing balancing valve of 100mm dia, complete all as specified and/or as directed by Engr-in Charge. |
| 47 | Taking down old unserviceable fuel pump and supply and fix, install, testing and commissioning fuel pump and motor of capacity 1 HP single phase 215 Volts, complete all as specified and/or as directed by Engr-in Charge. |
| 48 | S&F air release valve 25mm, complete all as specified and/or as directed by Engr-in Charge. |
| 49 | M&L for excavation in pot holes in so (or similar holes) not exc. 0.5 cum in hard/dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, complete all as specified and/or as directed by Engr-in Charge.. |
| 50 | M&L for PCC D-2 type (1:3:6), using 40mm graded crushed stone aggregate as in lean concrete, sub base or mass concrete, foundation filling etc., complete all as specified and/or as directed by Engr-in Charge. |
| 51 | S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS1161-1979 grade St-240, complete all as specified and/or as directed by Engr-in Charge. |
| 52 | Maintenance Of Electric Panels : Taking down old unserviceable/rusted LT panel and supply, installation, testing and commissioning in replacement, LT Panel cubical type indoor floor mounted weather proof totally enclosed, (CPRI approved) factory made and made out of 2.0 mm thick CRCA powder coated sheet and angle iron complete with bus bar of copper of suitable size for capacity 400 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame including space to accommodate 10 Nos Dol stater compatible for monoblock motor and pump of capacity upto 10 HP each on seperate housing including painting of panel with two coats of synthetic enamel paint over a coat of red oxide primer having IP-54 and conforming to IS-8623 and including following accessories:-Incoming(a) MCCB 160 Amps 4 pole with short circuit and earth fault protection with earth module breaking capacity 35 KA- 01 No (b) Change over switch open execution type 160 Amp 4 pole - 01 No Outgoing(c) MCB TP 32 Amps, 240 Volts, 50 Hz 'C' curve type- 06 Nos(d) MCB SPN 63 Amps, 240 Volts, 50 Hz 'C' curve type - 06 Nos(e) DOL stater 3 phase 415 V - 06 Nos(f) DOL stater 1 phase 230 V- 02 Nos(g) Digital Volt meter with sellector switch (g) Digital Amp meter with sellector switch with necessary CT (h)) LED indicating lamp - 11 Set Note :- (i) All MCCBs / instruments / MCBs / Bus Bar and starters shall be housed in a seperate housing with on- off latches in the housing |
| 53 | M&L for disconnecting the all connection in existing boiler control panel board complete and re-fixing the same after removing the burnt lugs/thimbles complete including replacing the U/S MCCBs, contactors, relay, bus bar indicator lamps etc. and complete painting work, complete all as specified and/or as directed by Engr-in Charge.Note : MCCBs, Contactors, relay, indicator lamps, S/Switchs are to be measured and paid seperately. |
| 54 | S&F in replacement of over load relay 8 to 12.5 Amps for contactor matching series ML 2 & 3, complete all as specified and/or as directed by Engr-in Charge.Cat No of L&T SS91859OOAO Make- Siemens, Havells. |
| 55 | S&F in replacement of digital type volt meter 0-500 volts, complete all as specified and/or as directed by Engr-in Charge. Make- L&T WDS301FEV00 or Schneider/ AE. |
| 56 | S&F in replacement of digital type Amp meter complete with suitable CTs 0-300 Amps, ccomplete all as specified and/or as directed by Engr-in Charge. Make- L&T WDS301FCA00. |
| 57 | S&F in replacement of indicating lamps RYB as per existing, complete all as specified and/or as directed by Engr-in Charge. |
| 58 | S&F in replacement of rotary type ON/OFF switches, 22mm dia as per existing, complete all as specified and/or as directed by Engr-in Charge.Make L&T -LCKB90S2 |
| 59 | S&F in replacement of push button switch in RED or GREEN colours, 22mm dia as per existing, complete all as specified and/or as directed by Engr-in Charge. |
| 60 | S&F in replacement of PVC flexible copper multistrand wire 3 core of 6 sqmm as per existing, complete all as specified and/or as directed by Engr-in Charge.Make- RR Kabel/Havells/Anchor. |
| 61 | S&F in replacement of PVC flexible copper multistrand wire 2 core of 6 sqmm as per existing, complete all as specified and/or as directed by Engr-in Charge.Make- RR Kabel/Havells/Anchor. |
| 62 | M&L for disconnecting old unserviceable control panel board and S&F control panel suitable for 3 to 4 lakh kilo/cal/hr boiler panel board, indoor cubical type, made out of 3.15 mm thick CRCA sheet powder coated for load bearing members for single side openable and covers, suitable for 3 phase 4 wire 50 cycle 500 Volts system weather and vermin proof, including internal wiring with suitable size copper cable, heat shrinkable sleeves, chromium plated brass cable glands, lugs/thimbles complete including the following parts, complete as compatible for existing boilers, complete all as specified and/or as directed by Engr-in Charge :- (i) MCBs 32-63 Amp - 01 No(ii) Contactors 32-63 Amp - 06 Nos(iii) Over Load relay 8 to 12 Amp - 01 No (iv) Indicator lamps - 04 Nos (v) S/Switchs - 02 Nos(v) Voltmeter - 01 No(vi) Ammeter - 01 No(vii) Temp Sensor - 01 No(viii) Temp display - 02 Nos |
| 63 | Repair/replacement of PVC insulated, heavy duty, LT XLPE galvanised steel strip armoured electric power cable of size 95 sqmm x 3.5 core with stranded aluminium conductor 1100 Volts grade, jointed with cable glands, lugs etc., laid in trenches/drawn through pipe, with and including taking down old unserviceable cable, complete all as specified and/or as directed by Engr-in Charge.Make: Havells/Gloster/Polycab. |
| 64 | Excavation in trenches, not exc. 1.5m wide & not exc. 1.5m in depth for foundation etc. in hard/dence soil & getting out for laying of cable, complete all as specified and/or as directed by Engr-in Charge. |
| 65 | Returning, filling in including spreading, leveling, watering & well ramming in layers not exc. 25cm cum thick, complete all as specified and/or as directed by Engr-in Charge. |
| 66 | Removing of surplus excavated soil to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 mtr above the starting point, complete all as specified and/or as directed by Engr-in Charge. |
| 67 | M&L for sand in trenches as in cushioning to under ground cable spreading, levelling hand punning, complete all as specified and/or as directed by Engr-in Charge.Note- Punned down thickness will be measured for payment purpose. |
| 68 | Supply and laying unreinforced pre cast concrete cable cover class LV type I flat size 250x150x40mm,complete all as specified and/or as directed by Engr-in Charge. |
| 69 | Labour only for laying of old serviceable cable covers retrieved from excavation,complete all as specified and/or as directed by Engr-in Charge. |
| 70 | S&F structural steel, rolled section such as joint, beam, channel, angle, tee, in available lengths including cuttings, welding as required at site, complete all as specified and/or as directed by Engr-in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 21, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Oct 10, 2026
18:00 IST
Corrigendum-1 Issued