Tender For Supply & Fixing Of Advance Lightning Protection System I.E, Lighting Arrestor At Nagarayan Bhawan, By Central Mechanical Division Under Ud &Ma Department.
Tender Value
5.77 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
0 days left
EMD
11542
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply & Fixing Of Advance Lightning Protection System I.E, Lighting Arrestor At Nagarayan Bhawan, By Central Mechanical Division Under Ud &Ma Department.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, installation testing & commissioning of ESE type lighting arrestor having protection radius more than 90 mts, time gain 60 microsecond along with lighting strike counter, minimum 5 mtrs. LA supporting mast, stay wire, downard copper strip conductor 25 x 6 mm, insulator 3 nos. earthing as per technical spection and approved drawong and all complete up to satisfication of EIC. |
| 2 | Supply and delivery of external, wide area early streamer emission ORP 60 type lighting arrestor made of robust stainless steel & tested standard stated in French standard NF C17-102, and IEC 62305-2. It is capable pf polarizing the trip with a voltage of 600V to 10-20kV/m synchronized with an approaching lighting and triggering a powerful upward streamer with speed of 1m/qs into the air, with average time gain of 60 microseconds earlier than aturally formed dtreamer. Its upward streamer are strong enough to withstand applicable cyclonic wind speeds. The serial number display on the ESE lighting attester shall be duly supported with the \\"certificate of country of orgin\\" issued indicating the serial number of the product supplied. The ESE terminal must offer protection radius of 79Mts. in protection level-I( high protection) and perferable to mounted the truss structure top. Make ABB/LPI. |
| 3 | Supply and installation of stainless steel support mounting mast 30 mm dia. To hold early streamer OPR 60 of robust design with guy wire and base plate alongwith all accessories like clamps, shaddles, holding arrangement to fix mast to bulding structure at highest point such that the air terminal is 5 mtr. above the tallest structure mounting mast(2 mtr. and 3 mtr with guy wire and base plate) Make ABB/LPI |
| 4 | Suupply and installation of lighting stroke counter or king electro mechanically without any power supply. The recorder shall be of non-reaettable type with the electro-mechanical display. No LCD screen is permitted as it may depend upon the battery life to energize the LCD. The lighting stroke recorder shall be duly tested & certified inline with the ESE lighting arrestor in an international labotary for an impulse current (8/20 micro sec) and count lighting strokes of 0.kA to 150kA Make ABB/LPI |
| 5 | Supply and delivery of copper strip 25 x 6 mm |
| 6 | Supply and installation of 1 x 70 sq mm multistranded Copper conductor PVC insulated and PVC sheathed unarmoured cable. |
| 7 | S & F of Sintex SMC/FRP water proof type looping cble box on newly erected pole 240 x 130 x 95 mm depth having hinged front cover & kitkat fuse unit one no. NL on insulator, 1 no. 4way bakelite connector for 2 nos. compression gland for upto 3 core 16 sq mm PVC/A cable and having lined with rubber gasket front cover with brass machine screw etc. earthing with lug on sheet tubler pole & nuts etc. complete in all rspect as per direction of EIC. |
| 8 | Finishing of the 70 Sq mm PVC insulated Copper wire ends by socketting with ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. |
| 9 | Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. |
| 10 | Excavation of soil for installation of Earth Electrode and filling& ramming For Soft Soil |
| 11 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: by ISI-Medium GI pipe. |
| 12 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. |
| 13 | GST@18% on total amount |
| 14 | CESS@1% on total amount Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodaySep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender