Tender For Addition Alteration To Room No. 106 At North Block Hq Swc At Jaipur Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises complete all as specified and directed. |
| 2 | M&L for light shade full body vitrified ceramic tiles 8-10mm thick (square/rectangular) polished, double charged, area of each tiles exc 0.42 sqm but n exc 1.00 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in CM 1:6 complete all as approved and directed. |
| 3 | Demolition of brick work or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 4 | S & F 8mm thick Cement fibre board made of asbestos free material with sound resistant, impact resistant, termite resistant, Fire resistant, fixing to 50mm x 25mm x 0.80 mm thick Galvanised iron channel including making frame with screws, Nailing etc for wall cladding/ framing work complete all as specified and directed. |
| 5 | Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each with shutter (without taking off shutter from the frame) and removing from site complete all as specified and directed. |
| 6 | S& F Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed |
| 7 | S & F 12mm thick toughned glass door plain glass with bending stress 120 to 200 N/mm2, having thermal shock resistance upto 2500C, command symbol embossing type including necessary SS clamps, corner clamp, SS locks with keys for glass door fixed at bottom of door and other fixing arrangement to hold the glass and packing all sides including making good existing damaged structure while executing the glass work complete all as specified and directed by Engr-in-Charge.Note : Steel handle and floor door spring will be paid separately, work executed on vertical portion and upto the height of 25 mtr, rate of necessary scaffolding, saftey gear for labour, necessary tools for work all are included in the item and not paid separately. |
| 8 | S & F Stainless steel (SS-304 grade) cast type section (handle) 300mm long D type as per sample approved by GE/Engineer-in-charge fixed in toughened glass door complete all as specified and as directed. |
| 9 | S & F 12mm thick toughned glass partition with bending stress 120 to 200 N/mm2, having thermal shock resistance upto 250 degree C, frosted type/ plain / embossing type including necessary fixing arrangement to hold the glass on RCC structure and packing all sides including making good existing damaged structure while executing the glass work complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for complete removal of existing treatment by mechanical means on old plastered surfaces of walls, including cleaning of any mortar drops, fungus efflorescent salts etc, preparation of surfaces and applying two coats of premium acrylic smooth interior emulsion paint, 1st quality (company depot tinted) of approved manufacturers in required colour and shade using hand roller over and including two coats of acrylic water based interior grade priming paint over two coats of acrylic wall care putty complete all as specified and directed.Note : 1. The Work Shall executed through company authorised applicators only.2. The work shall be carried out as per manufacturers instruction |
| 11 | S & F in repair window blind open and close verticaly or horizonatly with the help adjustment rope on tube (roller), made up of good fabric, plastic or other approved good material best locally available in market including all necessary assesories for installation and making good the surface compliete all as specified and directed by Engr-in-Charge |
| 12 | Providing and Fixing Channelled perforated panels of width 192mm, thickness of 15mm and length 2400 mm, made of a Moisture resistant fibre board substrate with a laminated facing as per the approved shade (Portland Maple, Sea Beech, Siam Wood & Mystique Walnut, Interior White, Alumina Pearl) and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the reverse surface has a “Helmholtz” fluted perforation with consecutive 3mm wide groove followed by 13mm of visible pane. The edges of the panel shall be “tongue-and-grooved” to fix special clips for installation and seamless visual. The back of the perforated panel shall have sound absorbing non-woven Soundtex acoustical fleece hot pressed to achieve NRC of 0.6. (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 and Humidity Resistance (RH) of 70% with camber limit less than 1mm/1000mm and bow less than 1mm/300mm.The panels shall be mounted on special aluminium splines (keel) using inside clips provided by Manufacturer and approved by the Architect/ Engineer-in-Charge. The panel shall be mounted by tongue and groove mechanism using inside clip on aluminium extruded keel made of Grade 6063-T5 having dimensions 3000(L) x 24(H) x 15.5(W) fixing @ 600-750mm spacing along horizaontal direction.The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. INSTALLATION:An appropriate vapour barrier (by others) shall be applied/installed on the vertical surface before the installation to properly seal against entry of any moisture. Vapour barrier (by others) shall be installed as per Manufacturer’s recommendation. Install wooden batten grid (provided by others) of section 50x50mm or as approved by the Architect on the solid wall/partition to provide level and plumb surface for fixing Keel. Install Keel vertically using screws and plugs at spacing of not more than 600mm centre-to-centre. The first and last keel should not be more than 150mm from the ends. Trim the tongue of the first bottom panel and install using headless nail with groove side upward. Subsequent panels are installed with tongue side downward by engaging with each other using tongue and groove mechanism and secured by inside clip. Continue this process until required height is achieved. Shorter butt edges need to be joined using industrial/wood glue. The keel shall also be used for transition of the butt end of adjacent panel at every 7.2m. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge. Finish off the edges using wooden moulding of matching colour (by others). Installation should be carried out as per Manufacturer recommended procedure. |
| 13 | Providing & Fixing of Fibre Glass Acoustical Suspended Ceiling System with 15mm thick Microlook 90 Edge Tiles with 15mm Bolt Slot exposed grid. The tiles shall have smooth laminated visual with Humidity Resistance (RH) of 95%, NRC 0.85 – 0.95 (Average value of Absorption Co-efficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, , Light Reflectance ≥88% as per ASTM E-1477, Colour Pebble White, Fire Performance of Class 0/1 as per BS 476 Part 6/7 with 20/25mm Square Tegular/Microlook 90 ̊ edge and 8mm drop in module size of 600 x 600mm. It shall be suitable for Green Building application, with Recycled content of 85%.SUSPENSION: The tile shall be laid on grid system with 15mm white flanges incorporating a 6mm central reveal in white/black colour with mitred ends & “bird’s mouth” notches to provide mitred cruciform junctions colour global white. Grid shall have double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 7.9 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 9.5 kg/m. The end details of the cross tee shall be made of pre hardened steel clip fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of 90 gsm as per IS 277 (2003) pre-painted steel with baked polyester paint of 0T bending capability. INSTALLATION: To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner shall not be greater than 450mm from the adjacent wall along with the first and the last main beam shall be at less than 600mm from the wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls using screws at 450mm centre to centre maximum. Installation shall be carried out as per Manufacturer recommended procedure. SUSPENSION SYSTEM accessories supplied by Manufacturer consisting of M6 Anchor Fasteners with hanger hole, pre-straightened hanger wire of dia– 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum loading strength of 110 kgs. (Optionally, adjustable hook clips made of 0.7mm thick Grade 1 C55 galvanized spring steel of dimension 100 x 20mm and 4 mm aquiline wire to be used for level adjustment during installation purpose in main runners including taking down old false ceiling |
| 14 | Taking down carefully aluminum /copper point wiring, casing capping /PVC concealed conduit for (light, fan, socket, bell or power etc) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified and directed. |
| 15 | M&L for modular point wiring with 1100 volts grade PVC insulated, unseathed, FRLSH multistranded copper conductor cable (conforming to IS:694 /1990), single core, 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) connecting to common earth dolly drawn through and including concealed rigid non metallic PVC conduit medium grade of size not less than 20mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor including cutting chases in walls for conduits and sunken boxes etc incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for one light/fan/exhaust fan point controlled by one, one way switch 6 Amp and making good the disturbed portion as per existing complete all as specified and directed. |
| 16 | ,---ditto--- all as per item No. 15 above but point wiring for one 3 pin 5 Amp socket outlet controlled by one switch on indepdendent board complete all as specified and directed. |
| 17 | ,---ditto--- all as per item No. 15 above but for point wiring for one 3 pin 5 Amp socket outlet controlled by one switch on same board with other switches complete all as specified and directed. |
| 18 | ,---ditto--- all as per item No. 15 above but wiring with cable of size 2.5 Sqmm for one 5 pin 15 Amps socket outlet controlled by one switch on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engr-in-Charge. |
| 19 | M&L for modular point wiring with 1100 volts grade PVC insulated, unseathed, FRLSH multistranded copper conductor cable (conforming to IS:694 /1990), single core, 4 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4 sqmm (Green) connecting to common earth dolly drawn through and including concealed rigid non metallic PVC conduit medium grade of size not less than 25mm dia ISI marked ivory colour with all conduit fittings / fixing accessories concealed in wall/ roof/floor including cutting chases in walls for conduits and sunken boxes etc incl modular sunken GI metal boxes not less than 1.0mm thick moulding in wall and incl white modular cover plates with frame for mounting modular switches, sockets, fan regulators etc as required for or one 5 pin 15 Amps socket outlet controlled by one switch on independent board and making good the disturbed portion as per existing complete all as specified and directed. |
| 20 | S&F modular switch, 6 Amps, one way, 240 volts, 1 module complete all as specified and directed. |
| 21 | S&F modular socket outlet 2/3 pin 6 Amp, 230 Volts, 2 Module flush type complete all as specified and directed |
| 22 | S&F modular switch 16 Amps, one way, 240 volts, 1 module complete all as specified and directed. |
| 23 | S&F modular socket, 6/16 Amps, 2/3pin combined, 2 module AC 240 volts complete all as specified and directed. |
| 24 | S&F modular hum free electronic step fan regulator 120-280 volts of 120 watts capacity including connecting up complete all as specified and directed. |
| 25 | S&F modular RJ 45 socket with shutter complete all as specified and directed. |
| 26 | S&F ceiling rose PVC polycarbonate isolated body, 3 terminals 230 Volt complete all as specified and directed |
| 27 | S&F electric door bell AC 240 volts, single pole complete all as specified and directed. |
| 28 | S & F in repair 20 amp single pole and neutral enclosure with 2 pole and earth metal enclosed plug top in powder coated CRCA steel sheet enclosre recess mounted with chained matel cover for socket out let with and incl one double pole MCB 20 Amps complete all as specified and directed. |
| 29 | Taking down existing MCB distribution board any type including accessories complete all as specified and directed |
| 30 | S&F flush mounting factory made MCBs Distribution board SPN, 8 ways, powder coated, CRCA steel sheet, degree of protection IP-43, IK-09 with reversible double door, 240V, recess mounted having insulated 200 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. Note : MCCB, MCBs and MCB DB shall be of the same make. |
| 31 | S&F flush mounting factory made MCBs Distribution board, tripple pole and neutral (VTPN) 8 ways, powder coated, CRCA steel sheet, suitable for MCCB incomer, degree of protection IP-43, IK09 with reversible double door, 415V, recess mounted having insulated 160 amp tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plate in unused spaces as required, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed.Note : MCCB, MCBs and MCB DB shall be of the same make. |
| 32 | S & F molded case circuit breaker (MCCB), four pole, 125 Amp, 415volt, adjustable type, with breaking capacity 16KA, incl all fitment assessories, suitable size nut and bolt, drilling work as per required and electric connection, as per existing make, size and shape and testing & commisioning and make good complete all as specified and directed. |
| 33 | S&F MCBs of 'B' curve single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. |
| 34 | S&F MCBs of 'C' curve double pole 10-32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. |
| 35 | S&F MCBs of 'C' curve double pole 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete all as specified and directed. |
| 36 | S&F in repair energy efficient recessed mounted LED Panel light 36 watt suitable for 2'x2' grid ceiling with CRCA powder coated housing & high transmittance Opal diffuser for glare free with Electronic LED Driver. IP20, PF ≥0.95, System Lumens ≥100 lm/W, 5700k CRI ≥ 80, Operating Voltage range 140 V - 270 V duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required complete all as specified and directed. |
| 37 | M&L for renewal of sub main wiring with two run of 4 Sqmm single core, PVC insulated, unsheathed, FRLSH multistranded copper conductor cable (confirming to IS 694/1990) alongwith one run of 4 Sqmm earth wire as earth continuity conductor (Phase-Red, Neutral-Black, Earth-Green) drawing into and including concealed rigid non-metallic PVC conduit not less than 20mm dia, medium duty, ISI marked, ivory colour with fitting / fixing accessories of suitable size as required including making connection as required incl taking down old wiring with casing capping / conduit complete all as specified and directed. NOTE - Two run of 4 sq.mm phase and neutral wire, One run of 4 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. |
| 38 | ,---ditto-- all as per item No. 37 above but wiring with two run of 6 Sqmm phase & neutral wire and one run of 6 Sqmm earth wire in 20mm dia PVC conduit complete all as specified and directed. NOTE - Two run of 6 sq.mm phase and neutral wire, One run of 6 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. |
| 39 | ,---ditto-- all as per item No. 37 above but wiring with Four run of 10 Sqmm wire and one run of 10 Sqmm earth wire in 32mm dia PVC conduit complete all as specified and directed. NOTE - Four run of 10 sq.mm wire, One run of 10 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. |
| 40 | ,---ditto-- all as per item No. 37 above but wiring with Four run of 16 Sqmm wire and one run of 16 Sqmm earth wire in 32mm dia PVC conduit complete all as specified and directed. NOTE - Four run of 16 sq.mm wire, One run of 16 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. Please Enable Macros to View BoQ information |
| 41 | ,---ditto-- all as per item No. 37 above but wiring with Four run of 16 Sqmm wire and one run of 16 Sqmm earth wire in 32mm dia PVC conduit complete all as specified and directed. NOTE - Four run of 16 sq.mm wire, One run of 16 sq.mm earth wire & One run of PVC conduit with accessories shall be measured as One length. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodaySep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender