Tender For Replacement Of Iei And Allied Electrical Works At Atal Adarsh Balika Vidyalya, Gole Market And Renovation Of Toilets Of Sbs Place Electrical Enquiry
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Sep 2026
6 days left
EMD
49027
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Iei And Allied Electrical Works At Atal Adarsh Balika Vidyalya, Gole Market And Renovation Of Toilets Of Sbs Place Electrical Enquiry
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group - C(LIGHT POINT-92,FAN POINT-60,EXHAUST POINT-23) |
| 2 | Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 4 | (b) 2x10 sq. mm. + 1x6 sq. mm earth wire. |
| 5 | (c)4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 6 | S&F metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in Front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as reqd. |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, Connections etc. as required. |
| 8 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box / wooden block including connections etc. as required. |
| 9 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 10 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 35-50 watt. make- BAJAJ /ORIENT /CROMPTON / HAVELLS/USHA (a) 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 11 | (b) 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 12 | LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness>1.20 mm), 18-22 Watt.Make:- Philips / Havells / Bajaj / Crompton |
| 13 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.as required (a) upto 450 mm sweep |
| 14 | Supply, installation, testing, and commissioning of a heavy-duty exhaust fan suitable for continuous ventilation (size as mentioned below). The fan shall operate on 230V AC, 50 Hz, equipped with a copper-wound motor having thermal overload protection and sealed ball bearings for long life. The fan shall deliver a minimum air delivery of 900–1350 m³/hr with low noise operation. The body and front guard shall be made of powder-coated metal or high-strength ABS polymer depending on the model, with three aerodynamically balanced blades ensuring smooth, vibration-free running. The exhaust fan shall also include a factory-fitted louvers/shutter mechanism for preventing reverse airflow, insects, and dust ingress. Installation includes fixing of fan frame using anchor fasteners, providing necessary supports, and sealing gaps around the fan with cement mortar/PU sealant for dust-free installation. The exhaust fan s should have IS 2312 and minimum IPX4 protection or better suitable for ventilation application. The fan shall be of approved make such as Crompton / Havells / Usha / Orient / Bajaj or equivalent, complete with all accessories with02 years warranty. (a) 380 mm (15 inch) |
| 15 | S&F Of Cubical board made out of CRCA Sheet 16SWG, powder Coated of Size 600x750x300mm deep (nominal) suitable for supply and installation of MCCB 250A 25KA Breaking Capacity,4 pole ,415V Copper Bus-bar Chamber having 4 nos. 250A Capacity, copper bus bar of suitable size/rating, one set of Amp and Volt meter with Selector Switch RYB indicating Lights including wiring with 16 Sq mm copper wire, thimbles, nut boltsalong with grounding in the wall including connection\ testing ,commissioning, painting and providing locking arrangement along with lock 65mm size, provision for ventilating air fins, handle for opening of door, fixing danger plate, including masonry/white washing work etc. complete as required as site. |
| 16 | Supply & fixing of cubical board made out of CRCA sheet 16 SWG, powder coated, of size 750 × 450 × 300 mm (nominal), suitable for installation of 125 A,36KA, 4P MCCB as incomer. The cubical board should be Providing and fixing with 1 No. 125 A,36KA, 4P breaking capacity, 4 Pole MCCB as incomer with thermomagnetic release and terminal spreaders the cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required, including all internal connections, mounting, and termination and The panel should be provided with copper bus-bar chamber having 4 Nos. copper bus bars of suitable size (25 mm x 5 mm x 200 mm or as required for 125 A rating) with proper supports, insulation, and terminations. The cubical board should be provided with adequate neutral link and a separate earth link (earth bar) of suitable capacity with multiple termination points. The panel shall include Ammeter, Voltmeter with selector switch, RYB indicating lamps, and complete internal wiring using suitable size copper conductors of 16 sq. mm. wire, thimbles, and accessories. Proper ferruling, numbering, dressing of wiring with cable ties, and colour coding as per IS standards shall be ensured. The work includes grouting in the wall, complete connection, testing, commissioning, painting, and providing locking arrangement with 65 mm size lock, ventilation louvers, door handle, and danger plate. All masonry and whitewashing work required for installation shall be included. The scope also includes dismantling and safe removal of the existing electrical panel, proper disconnection of old cables, and installation of the new panel either flush or surface mounted as per site requirement, ensuring proper alignment. All incoming and outgoing cables shall be terminated using ISI-marked copper thimbles and secured with appropriate machine screws, nuts, bolts, and washers. Proper ferruling and numbering shall be done for all wires. Internal wiring shall be neatly arranged using insulated bus bar links and sleeves. Wiring shall be properly dressed with cable ties for a clean and professional finish. Colour coding shall be strictly followed as per IS standards: red, yellow, and blue for phases, black for neutral, and green for earthing. Clear and permanent printed labels shall be provided for the incomer and each outgoing circuit, along with a proper panel nameplate. All internal connections shall be carried out using insulated copper conductors of adequate capacity, ensuring safety and reliability with no loose connections. Make of MCCB:- Havells /Legrand /SchneiderElectric / L&T Electrical & Automation |
| 17 | Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender