Tender For Item Rate E-Tender For Electrical Work In The Library Block And Old Science Block At Maitreyi College, Chanakya Puri, New Delhi-110021.
Tender Value
2.32 Crore
Estimated cost
Bid Submission
05 Oct 2026
20 days left
EMD
4.65 Lakhs
Bank guarantee accepted
Document Fee
1500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Item Rate E-Tender For Electrical Work In The Library Block And Old Science Block At Maitreyi College, Chanakya Puri, New Delhi-110021.
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. |
| 2 | Group C |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 6 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 7 | 2 x 6 sq. mm + 1 x 6 sq. mm earth wire |
| 8 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 9 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 10 | 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 12 | 25 mm |
| 13 | Supplying and fIxing following modular switch socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 14 | Bell push |
| 15 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 17 | Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fluxing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 18 | Supplying and fixing suitable size Gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 19 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 20 | 5/6 A switch |
| 21 | 2-way 5/6 A switch |
| 22 | 15/16 A switch |
| 23 | 3 pin 5/6 A socket outlet |
| 24 | 6 pin 15/16 A socket outlet |
| 25 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required |
| 26 | 1 or 2 Module (75mmX75mm) |
| 27 | 3 Module (100mmX75mm) |
| 28 | 4 Module (125mmX75mm) |
| 29 | 6 Module (200mmX75mm) |
| 30 | 8 Module (125mmX125mm) |
| 31 | 12 Module (200mmX150mm) |
| 32 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 33 | Supplying and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length, wiring with 2 X 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored). |
| 34 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 35 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 36 | Upto 450 mm sweep |
| 37 | 510 mm sweep |
| 38 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based)for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 39 | Brush Less Direct Current (BLDC) Fan with Remote 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 40 | Brush Less Direct Current (BLDC) Fan without Remote1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 41 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board 240 V. on surface récess, complete with toned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc as required. But without MCB/RCCB/Isolator). |
| 42 | 12 way Double door |
| 43 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with linned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 44 | 8 way (4+24), Double door |
| 45 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve. miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required |
| 46 | Single pole |
| 47 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 48 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 49 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 50 | Above 185 sq. mm and upto 400 sq. mm |
| 51 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 52 | Above 185 sq. mm and upto 400 sq. mm |
| 53 | Supplying and fixing of Wall Fan 300 mm |
| 54 | Supplying and Fixing of snap-on DLP trunking of size 80 mm x 50 mm with cover and including accessories such as Flat angle and caps, internal/external angle support etc. on the wall /surface complete all as required. |
| 55 | Supplying and Fixing of snap-on DLP trunking of size 105 mm x 50 mm with cover and including accessories such as Flat angle and caps, internal/external angle support etc. on the wall /surface complete all as required. |
| 56 | Supplying and Fixing of snap-on DLP trunking of size 130 mm x 50 mm with cover and including accessories such as Flat angle and caps, internal/external angle support etc. on the wall /surface complete all as required. |
| 57 | Supplying and Fixing of snap-on DLP trunking of size 145 mm x 50 mm with cover and including accessories such as Flat angle and caps, internal/external angle support etc. on the wall /surface complete all as required. |
| 58 | Supplying and Fixing of snap-on DLP trunking of size 180 mm x 50 mm with cover and including accessories such as Flat angle and caps, internal/external angle support etc. on the wall /surface complete all as required. |
| 59 | Supplying of PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade 3.5 cr x 240 sq mm |
| 60 | Removal of old wiring from steel conduit and managing scrap. |
| 61 | Panel work |
| 62 | As per design/drawing approved by the Engineer-in-Charge at the site |
| 63 | Supplying, Installation, Testing & Commissioning i/c making foundation of cubical type Feeder Pillar Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 500 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears. Size of Feeder Pillar : 1.0 mtr x 0.9 mtr x 300mm deep. |
| 64 | Incomer |
| 65 | 1 Nos. 1000 Amps. FP MCCB of KA with inbuilt protection. |
| 66 | MAIN BUS BARS |
| 67 | TPN aluminium bus bars of minimum of 1000 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec. |
| 68 | METERING Make |
| 69 | i) 1 nos. 0-500V Digital type Voltmeter with selector switch & protection MCB |
| 70 | ii) 1 nos. 0-400A Digital type Ammeter with selector switch with CT's 400/5A |
| 71 | iii) 3 Nos. phase indication lights LED type with protection MCB. |
| 72 | OUTGOINGS |
| 73 | i) 2 Nos. 400 Amps. FP MCCB of 50 KA with inbuilt protection. |
| 74 | ii) 2 Nos. 160 Amps. FP MCCB of 25 KA with inbuilt protection. |
| 75 | Total Panel Cubical Type Feeder Pillar AS DESCRIBED ABOVE COMPLETE IN ALL RESPECT. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 14, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender