Educational and Research Institute Boards / Undertakings / PSU Closing in 4 days TDR #57501936

Tender For Provision Of False Ceiling, Sound Proofing And Necessary Electrical Work Along With The Provision Of Air Conditioning In The Seminar Hall/Committee Room In Economics Building, Faculty Of Social Science, Bhu.

Issued by Boards / Undertakings / PSU · Varanasi, Uttar Pradesh
Tender Value
29.42 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
4 days left
EMD
58858
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of False Ceiling, Sound Proofing And Necessary Electrical Work Along With The Provision Of Air Conditioning In The Seminar Hall/Committee Room In Economics Building, Faculty Of Social Science, Bhu.

BOQ

Name of Work:- Provision of False Ceiling, sound proofing and necessary electrical work along with the provision of Air Conditioning in the Seminar Hall/Committee room in Economics Building, Faculty of Social Science, BHU.
Sl. No. Item Description
1Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (8.31)
2Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead (15.56)
3Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles (26.24.1)
4Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (6.13.2)
512 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (13.4.2)
615 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) (13.5.2)
7Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (6.15)
8Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (10.16.1)
9Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (12.50)
10Factory made 50mmx47mm with a wall thickness of 5mm door frame PVC extruded sheet i/c carriage Two or more coats on new work (13.61.1)
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (4.1.3)
12With common burnt clay F.P.S. (non modular) bricks Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (18.76.1)
13Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (15.2.1)
14Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group C Point (1.15.3)
15Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (1.10.3)
16Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (1.14.1)
17Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire (1.14.3)
18Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire (1.14.10)
19Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire (1.14.4)
20Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire (1.14.8)
21Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch (1.24.1)
22Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch (1.24.3)
23Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet (1.24.4)
24Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet (1.24.5)
25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (1.25)
26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required (1.26)
27Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 12 Module (200mmX150mm (1.27.6)
28Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
29Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
30Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings
31Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.
32Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door (2.4.1)
33Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required 4 way (4 + 12), Double door (2.5.2)
34Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole (2.10.1)
35Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required For 4 way, Double door TPN MCBDB (2.24.1)
36Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
37Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A,36KA,FPMCCB (2.2.14)
38Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3.5 x70 Sq. mm (9.1.22)
39Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC system, complete with fittings, with suitable adjustable and supports for Suction and Liquidlines, all accessories as per specifications etc. as required. 6.4 mm dia (OD) (Soft drawn) with tube thickness1.2mm with19mm thick insulation (5.1)
40Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC system, complete with fittings, with suitable adjustable and supports for Suction and Liquidlines, all accessories as per specifications etc. as required.9.5 mm dia(OD) (Soft drawn) with tube thickness1.2mm with 19mm thick insulation (5.2)
41Providing and fixing 6 SWG GI wire on surface /recess for loop earthing along with existing UG cable (5.18 )
42Supplying and fixing 63 A , 10 KA rating, Four pole ,415 V, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MR)
43Supplying and fixing 63 A , 10 KA rating,three pole ,415 V, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MR)
44Supplying ,Installation ,testing and commissioning of 400 mm sweep wall fan on wall with 50 watt capacity , 1350 rpm speed at 72 CMM air delivery rate made in plastic body & blade and metallic motor suitable for 230 volt 50Hz ,single phase AC supply with earthing connection including suitable size fastener for fixing & connection with FRLS 3 core wire etc complete as required at site. (Make-Havells /Orient/ Crompton/Usha) (MR)
45Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required..(Make-lycab/Universal/Grandlay/Gloster) 3.5 x95 Sq. mm (MR)
46Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required..(Make- polycab/Universal/Grandlay/Gloster)3.5 x95 Sq. mm (MR)
47Supplying and Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size for loose connection etc as required.(Make-Polycab/Universal/Grandlay/Gloster)3.5 x95 Sq. mm (MR)
48Supplying Installation Testing & Commissioning of 2 Ton Referigeration(TR) capacity Split type air conditioners having 3 star rating Inverter type , Rotary compressor, LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart and cooling capacity sholud be more than 6800 watt etc suitable for operation on 230 volts, 50 Hz, single phase A.C. Supply including suitable size wall bracket for fixing the existing 2 TR outdoor unit and factory fabricated mounting bracket duly powder painted of sheet steel suitable for outdoor unit with suitable dash fastner etc as required. (Make:-Daikin Model No FTKL71XV16MAA+RKL71XV16MAA or equivalen t specification of LLoyd /Hitachi / Bluestar / Carrier ) (MR)
49Supplying and fixing of 25 mm nominal dia U PVC pipe of rigid / Flexible U PVC pipe with minimum 6 mm thick nitrile rubber insulation along with all essential accessories and suitable clamp for drain pipe including connection to the indoor units etc as required. (MR)
50Dismantling the existing modular switch/socket cover plate complete with existing modular switches, sockets and accessories of various sizes (2 Module, 4 Module, 6 Module and 8 Module), without damaging the existing wiring, GI box or accessories, carefully storing the dismantled materials during execution of wall panelling work, and thereafter refixing the same on the existing GI box using suitable long-size zinc-plated/SS screws as required to suit the finished wall panel thickness, including alignment, tightening of terminals, checking continuity, testing of switches and sockets, making good minor adjustments, and commissioning complete in all respects as required at site (MR) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57501936
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 29.42 Lakhs
LAST DATE 19-09-2026
Authority
Authority Name Banaras Hindu University
Work Description Tender for Provision Of False Ceiling, Sound Proofing And Necessary Electrical Work Along With The Provision Of Air Conditioning In The Seminar Hall/Committee Room In Economics Building, Faculty Of Social Science, Bhu.
Basic Detail
Tender No UED/ED-II/2025/12092026-3
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 12 Sep 2026
Submission Date 19 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 29.42 Lakhs
Tender Fee 500
EMD 58858
Exemption Not Available
Document List
38f04643-7282-4d74-b8cd-a8e14a76b9ef.html
Bid_Document11.pdf
BOQ_973079.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

38f04643-7282-4d74-b8cd-a8e14a76b9ef.html

pdf

Bid_Document11.pdf

xls

BOQ_973079.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer