Tender For Provision Of False Ceiling, Sound Proofing And Necessary Electrical Work Along With The Provision Of Air Conditioning In The Seminar Hall/Committee Room In Economics Building, Faculty Of Social Science, Bhu.
Tender Value
29.42 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
4 days left
EMD
58858
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of False Ceiling, Sound Proofing And Necessary Electrical Work Along With The Provision Of Air Conditioning In The Seminar Hall/Committee Room In Economics Building, Faculty Of Social Science, Bhu.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (8.31) |
| 2 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead (15.56) |
| 3 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia,50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer's specification as per direction of Engineer-in-Charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles (26.24.1) |
| 4 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) (6.13.2) |
| 5 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) (13.4.2) |
| 6 | 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) (13.5.2) |
| 7 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (6.15) |
| 8 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes (10.16.1) |
| 9 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (12.50) |
| 10 | Factory made 50mmx47mm with a wall thickness of 5mm door frame PVC extruded sheet i/c carriage Two or more coats on new work (13.61.1) |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (4.1.3) |
| 12 | With common burnt clay F.P.S. (non modular) bricks Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (18.76.1) |
| 13 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) (15.2.1) |
| 14 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required Group C Point (1.15.3) |
| 15 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C (1.10.3) |
| 16 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (1.14.1) |
| 17 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire (1.14.3) |
| 18 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire (1.14.10) |
| 19 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire (1.14.4) |
| 20 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire (1.14.8) |
| 21 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch (1.24.1) |
| 22 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch (1.24.3) |
| 23 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet (1.24.4) |
| 24 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet (1.24.5) |
| 25 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (1.25) |
| 26 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required (1.26) |
| 27 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required 12 Module (200mmX150mm (1.27.6) |
| 28 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 29 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required |
| 30 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings |
| 31 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 32 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door (2.4.1) |
| 33 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required 4 way (4 + 12), Double door (2.5.2) |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole (2.10.1) |
| 35 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required For 4 way, Double door TPN MCBDB (2.24.1) |
| 36 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 37 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A,36KA,FPMCCB (2.2.14) |
| 38 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3.5 x70 Sq. mm (9.1.22) |
| 39 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC system, complete with fittings, with suitable adjustable and supports for Suction and Liquidlines, all accessories as per specifications etc. as required. 6.4 mm dia (OD) (Soft drawn) with tube thickness1.2mm with19mm thick insulation (5.1) |
| 40 | Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for Split AC system, complete with fittings, with suitable adjustable and supports for Suction and Liquidlines, all accessories as per specifications etc. as required.9.5 mm dia(OD) (Soft drawn) with tube thickness1.2mm with 19mm thick insulation (5.2) |
| 41 | Providing and fixing 6 SWG GI wire on surface /recess for loop earthing along with existing UG cable (5.18 ) |
| 42 | Supplying and fixing 63 A , 10 KA rating, Four pole ,415 V, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MR) |
| 43 | Supplying and fixing 63 A , 10 KA rating,three pole ,415 V, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (MR) |
| 44 | Supplying ,Installation ,testing and commissioning of 400 mm sweep wall fan on wall with 50 watt capacity , 1350 rpm speed at 72 CMM air delivery rate made in plastic body & blade and metallic motor suitable for 230 volt 50Hz ,single phase AC supply with earthing connection including suitable size fastener for fixing & connection with FRLS 3 core wire etc complete as required at site. (Make-Havells /Orient/ Crompton/Usha) (MR) |
| 45 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required..(Make-lycab/Universal/Grandlay/Gloster) 3.5 x95 Sq. mm (MR) |
| 46 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required..(Make- polycab/Universal/Grandlay/Gloster)3.5 x95 Sq. mm (MR) |
| 47 | Supplying and Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size for loose connection etc as required.(Make-Polycab/Universal/Grandlay/Gloster)3.5 x95 Sq. mm (MR) |
| 48 | Supplying Installation Testing & Commissioning of 2 Ton Referigeration(TR) capacity Split type air conditioners having 3 star rating Inverter type , Rotary compressor, LED panel display, LCD remote control, sleep mode, Anti Bacteria filter, Auto restart and cooling capacity sholud be more than 6800 watt etc suitable for operation on 230 volts, 50 Hz, single phase A.C. Supply including suitable size wall bracket for fixing the existing 2 TR outdoor unit and factory fabricated mounting bracket duly powder painted of sheet steel suitable for outdoor unit with suitable dash fastner etc as required. (Make:-Daikin Model No FTKL71XV16MAA+RKL71XV16MAA or equivalen t specification of LLoyd /Hitachi / Bluestar / Carrier ) (MR) |
| 49 | Supplying and fixing of 25 mm nominal dia U PVC pipe of rigid / Flexible U PVC pipe with minimum 6 mm thick nitrile rubber insulation along with all essential accessories and suitable clamp for drain pipe including connection to the indoor units etc as required. (MR) |
| 50 | Dismantling the existing modular switch/socket cover plate complete with existing modular switches, sockets and accessories of various sizes (2 Module, 4 Module, 6 Module and 8 Module), without damaging the existing wiring, GI box or accessories, carefully storing the dismantled materials during execution of wall panelling work, and thereafter refixing the same on the existing GI box using suitable long-size zinc-plated/SS screws as required to suit the finished wall panel thickness, including alignment, tightening of terminals, checking continuity, testing of switches and sockets, making good minor adjustments, and commissioning complete in all respects as required at site (MR) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender