Educational and Research Institute Boards / Undertakings / PSU Closing in 15 days TDR #57501914

Tender For Construction Of Path Way Shed From Gate No.4 To Emsd Building, Jipmer C Us, Puducherry.

Issued by Boards / Undertakings / PSU · Pondicherry, Puducherry
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Sep 2026
15 days left
EMD
1.78 Lakhs
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pondicherry → Puducherry
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Path Way Shed From Gate No.4 To Emsd Building, Jipmer C Us, Puducherry.

BOQ

Name of Work:- Construction of path way shed from Gate No.4 to EMSD Building, JIPMER C us, puducherry.
Sl. No. Item Description
1Item Description
2Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
3Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
4Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge In cement mortar
5Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.
6CEMENT CONCRET (CAST IN SITU) Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size).
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
8Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
9Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer with enamel paint all complete.
10Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, bending, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. The complete structure is finished with Epoxy paint colour with primer approved by the Engineer-in-charge. Hot finished welded type tubes
11Providing and fixing 18 mm thick machine saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, nitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm
12Centering and shuttering including strutting, propping etc. and removalof form for all heights : Foundations, footings, bases of columns, etc. for mass concrete sqm
13Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
1415 mm cement plaster on rough side of single or half brick wallof mix:(including scaffolding upto 5metre height) 1:4 (1 cement: 4 coarse sand) (including scaffolding)
1515 mm cement plaster on rough side of single or half brick wallof mix:(including scaffolding upto 5metre height) 1:4 (1 cement: 4 coarse sand) (including scaffolding) 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
16Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter
17Applying priming coat: : With ready mixed red oxide zinc chromate primer of approvedbrand and manufacture on steel galvanised iron/ steel works
18Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
19Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour- Two coats
20Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as requiredrequired.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
21Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6 A Double Pole
22Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Size 20 mm
23Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole 25 A ,30mA
24Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) withDriver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°Kcomplete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output . . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.heat sink of aluminium housing Powder coated die cast /Extruded aluminiumBody lm/Watt).20 Watts 2 FEET
25Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
26Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
27Supplying,installtion and testing of following size one number of XLPE Insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade as required at site including excavation and refilling etc.3C X 2.5 sq.mm
28Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.40 mm dia (OD-40 mm & ID-32 mm nominal)
29Supplying and fixing Double Pole sheet steel enclosure on surface/ recess DP MCB complete with connections, testing and commissioning etc. as required.2 Way SPN DB
30Design of shed work inluding architectural and structural drawing as directed by the Engineer-in-charge.
31Removing and re-fixing of MS steel grills as per the direction of engineer-in-charge
32Supplying and fixing of Tensile Membrane Fabric , The membrane should be minimum of ( Sioen, Hytex or equivalent) 1050GSM Tensile Membrane Fabric. The above fabric will be patterned, welded with the high frequency welding machine, end pockets to accommodate kedar profile and will be fixed using special aluminium extrusions to suit the structure. The complete structure will be designed for wind load, live loads etc. and per the directions of Engineer-in-charge. a) The masking carrying instruction as to which side UV protection and & Weather Resistantb) Fire retardant confirming as per ISc) Tensile Membrane Fabric with PVC-Coated Polyester with a minimum life span of 20 years. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57501914
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 30-09-2026
Authority
Authority Name Jawaharlal Institute Of Post Graduate Medical Education And Research
Work Description Tender for Construction Of Path Way Shed From Gate No.4 To Emsd Building, Jipmer C Us, Puducherry.
Basic Detail
Tender No JIP/ED/WORKS/2026/04
Bidding Type Tender
Location
City Pondicherry
State Puducherry
Key Dates
Publish Date 12 Sep 2026
Submission Date 30 Sep 2026
Open Date 01 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 590
EMD 1.78 Lakhs
Exemption Available
Document List
8b2c1b9f-5e04-4aab-a966-81ef5ec629d0.html
BOQ_973061.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 01, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

8b2c1b9f-5e04-4aab-a966-81ef5ec629d0.html

xls

BOQ_973061.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders