Tender For Construction Of Path Way Shed From Gate No.4 To Emsd Building, Jipmer C Us, Puducherry.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Sep 2026
15 days left
EMD
1.78 Lakhs
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pondicherry → Puducherry
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Path Way Shed From Gate No.4 To Emsd Building, Jipmer C Us, Puducherry.
BOQ
| Sl. No. | Item Description |
| 1 | Item Description |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m inwidth or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil anddisposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 4 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge In cement mortar |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m. |
| 6 | CEMENT CONCRET (CAST IN SITU) Providing and laying in position cement concrete of specified grade excludingthe cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). |
| 7 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 9 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer with enamel paint all complete. |
| 10 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, bending, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. The complete structure is finished with Epoxy paint colour with primer approved by the Engineer-in-charge. Hot finished welded type tubes |
| 11 | Providing and fixing 18 mm thick machine saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, nitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 12 | Centering and shuttering including strutting, propping etc. and removalof form for all heights : Foundations, footings, bases of columns, etc. for mass concrete sqm |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | 15 mm cement plaster on rough side of single or half brick wallof mix:(including scaffolding upto 5metre height) 1:4 (1 cement: 4 coarse sand) (including scaffolding) |
| 15 | 15 mm cement plaster on rough side of single or half brick wallof mix:(including scaffolding upto 5metre height) 1:4 (1 cement: 4 coarse sand) (including scaffolding) 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 16 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 110 mm diameter |
| 17 | Applying priming coat: : With ready mixed red oxide zinc chromate primer of approvedbrand and manufacture on steel galvanised iron/ steel works |
| 18 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 19 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour- Two coats |
| 20 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as requiredrequired.2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 21 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 6 A Double Pole |
| 22 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Size 20 mm |
| 23 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double Pole 25 A ,30mA |
| 24 | Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) withDriver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°Kcomplete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy ≥105 <120 lm/Watt output . . Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.heat sink of aluminium housing Powder coated die cast /Extruded aluminiumBody lm/Watt).20 Watts 2 FEET |
| 25 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 26 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 27 | Supplying,installtion and testing of following size one number of XLPE Insulated and PVC sheathed armoured aluminium conductor power cable of 1.1 KV grade as required at site including excavation and refilling etc.3C X 2.5 sq.mm |
| 28 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.40 mm dia (OD-40 mm & ID-32 mm nominal) |
| 29 | Supplying and fixing Double Pole sheet steel enclosure on surface/ recess DP MCB complete with connections, testing and commissioning etc. as required.2 Way SPN DB |
| 30 | Design of shed work inluding architectural and structural drawing as directed by the Engineer-in-charge. |
| 31 | Removing and re-fixing of MS steel grills as per the direction of engineer-in-charge |
| 32 | Supplying and fixing of Tensile Membrane Fabric , The membrane should be minimum of ( Sioen, Hytex or equivalent) 1050GSM Tensile Membrane Fabric. The above fabric will be patterned, welded with the high frequency welding machine, end pockets to accommodate kedar profile and will be fixed using special aluminium extrusions to suit the structure. The complete structure will be designed for wind load, live loads etc. and per the directions of Engineer-in-charge. a) The masking carrying instruction as to which side UV protection and & Weather Resistantb) Fire retardant confirming as per ISc) Tensile Membrane Fabric with PVC-Coated Polyester with a minimum life span of 20 years. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 30, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender