Tender For Construction Of 6 Unit Classroom At Residential Upgraded High School Dangapara District Godda.
Tender Value
1.48 Crore
Estimated cost
Bid Submission
28 Sep 2026
8 days left
EMD
2.97 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Godda → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 6 Unit Classroom At Residential Upgraded High School Dangapara District Godda.
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation in foundation trenches in ordinary soil (vide classfication of soil item - A) and disposal of excavated earth a obtained to a distance up to 50M including all lifts with leveling ramming the foundation trenches removing roots of trees shurbs all complete as per approved design and per building specification and direction of E/I. |
| 2 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B) |
| 3 | Earth filling in foundation trenches and plinth in layer not exceeding 150mm thick will watered rammed fully compacted and fine dressed with earth obtained from excavation of foundation trenched with a lead of 50mm and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume). |
| 4 | Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 5 | Providing coarse clean sand in filling in foundation trenches or plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts includng cost of all materials, Labour, rotalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume). |
| 6 | Providing designation 75B one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 12 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform |
| 17 | Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbels etc., including edges |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for : Stairs, (excluding landings) except spiral-staircases |
| 19 | Providing and mixing liquid integral water proofing compound in conctrete of plaster as manufacturer specification and as per direction of engineer in charge. Brand. Sika plastocrate plus, MYK proff WP 10, Fosroc-Conplast x 4211C, Dr.Fixit, Pidiproff LW+ or Equivalent |
| 20 | 8mm dia (35 % of total reinforcement) |
| 21 | 10mm dia (15 % of total reinforcement) |
| 22 | 12mm dia (20 % of total reinforcement) |
| 23 | 16mm dia (20 % of total reinforcement) |
| 24 | 20/25mm dia (10 % of total reinforcement) |
| 25 | Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l. |
| 26 | Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\" x 4.5\\" x 3\\") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 27 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 28 | Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 and including cost of screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per building specification and direction of E/I |
| 29 | Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I. |
| 30 | Textured exterior paint /exterior primer applied @ 2.20kg/10 |
| 31 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface toprepare the surface even and smooth complete |
| 32 | Providing two coats of oil bound distemper of approved make & shade over a coat of cement primer over new surface including preparing the plastered surface by rubbing, smooth with pumic stone or fine sand paper, aplying putty wherever required, scaffolding , washing of flores and taxes etc. all complete as per building specification direction of E/I. |
| 33 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 34 | Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 35 | DOOR - Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 36 | Supplying, fitting & fixing M.S. Grill made of 20x6mm flat as per approved design and drawing aproperly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I. |
| 37 | Providing primer one coat of red lead paint of approved make over steel surface including preparing the surface after cleaning removing dirt, scales, grease and sand papering, including cost of scaffolding etc. all complete as per building specification direction of E/I. |
| 38 | Providing 2 coats of Synthetic Enamel Paint of approved shade and make over steel surface grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I. |
| 39 | WINDOW- Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 40 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 41 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm |
| 42 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour andshade, with necessary screws etc. complete. Twin rubber stopper |
| 43 | Water proofing for Old and New Roof Slab :- Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with. brush, roller or spray for water proofing coating as per manufacturer specifications with following steps: (a)surface preparation :-Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint /coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt.Ltd. / MYK Schomberg Dr Fixit/Fosroc or equivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with 150mm X 150 mm fillet of mortar (Cement: sand -1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr Fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer. Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready touse, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application, 45 gsm of Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" (c) 2nd Coat :-To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured.\\" After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing Brand:-Sika Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2K/MYKAquafin TGProduct Performance Chemical Base Part A: Acrylic copolymer, Part B: Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +27°CTensile Strength -2 N/mm2 after 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength ~2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength ~4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370)(d) Protection of treated surface with PCC :- The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint. Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items). All corners shall be chamfered with 150mm X-150 mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika India Pvt.Ltd./MYK Schomberg / Dr Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\\"(e) Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately). Brand Sika India Pvt.Ltd. / MYK Schomberg / Dr Fixit/Fosroc. Warranty for five years. |
| 44 | Covering of treated surface with PCC :- Providing 25 mm thick Cement Concrete M20(1:1.5:3) maintaining slope in alternate 2 mt x 2 mt panels with aaproved quality of stone chips of 20 mm |
| 45 | Providing & fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion. Single socketed pipes. 110mm dia |
| 46 | Bend -110 mm |
| 47 | Shoe - 110mm |
| 48 | Coupler- 110mm |
| 49 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plgs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 50 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 51 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 52 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp of internal dia 140mm, 73mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3mmdia. round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bar bent to shape as per standard drawing. |
| 53 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 54 | Group B |
| 55 | Group C |
| 56 | Twin Control Point wiring in PVC conduit, with modular type switch:-Wiring for Twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, 2 way modular type switch,modular plate, sutiable size G.I box etc as requried. |
| 57 | 2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 58 | 2x2.5 sq.mm + 1x2.5 sq.mm earth wire |
| 59 | 2x4.0 sq.mm + 1x4.5 sq.mm earth wire |
| 60 | 2x10 sq.mm + 1x10 sq.mm earth wire |
| 61 | 75 mm x 75 mm x 50 mm deep / (4\\" x 4\\" ) |
| 62 | 72 mm x 146 mm x 48 mm deep / (4\\" x 7\\" ) |
| 63 | 210 mm x 206 mm x 48 mm deep / (10\\" x 12\\" ) |
| 64 | Bulk head fitting with 9/10 Watt CFL/LED |
| 65 | S/F celling rose :- Supplying and fixing 2 pin 5 amp. Celling rose on the existing junction box/ wooen block including connection etc. as requried. (Tube+Fan) |
| 66 | S/F Batten holder :-Supplying and fixing battrn / angle holder including connection etc as requried. (Tube only) |
| 67 | 15/16 Watt LED BULB |
| 68 | 10/12 . Watt LED tube LIGHT |
| 69 | 20/22 Watt LED tube LIGHT |
| 70 | ITC fluorescent fitting directly on surface :-Intallation testing and commissioning of pre wired fluorescent TUBE fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on celling / wall including connection with 1.5 sq. mm. FR PVC insulated copper conduit as requried. |
| 71 | 1200MM (48\\")Ceiling Fan |
| 72 | ITC celling fan :- Installation, testing and commissioning of celling fan, including wiring the down rods of standerd leanth (upto 30 mm) with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as requried. |
| 73 | S/F Modular type Electronic Fan Regulator-Supplying and fixing following modular type lectronic Fan Regulator- on the existing modular plate and switch box including connection but exculiding modular plate etc.as requried. |
| 74 | 5/6 amps, one way switch |
| 75 | 5/6 amps, 3 pin socket outlet |
| 76 | S/F power plug point with modular type accessories :- Supplying and fixing sutiable size G.I. box with modular plate cover in front on surface or in recessed including providing and fixing 6 pin , 15/16 amps modular socket outlet and 15/16 amps modular switch connection , painting etc, as requried. |
| 77 | 32 amps, double pole |
| 78 | 63 amps, double pole |
| 79 | 32 amps, TP&N |
| 80 | 6/32 amps, Single pole |
| 81 | 4way,Single door |
| 82 | 6way,single door |
| 83 | 8 way , single door |
| 84 | 4way, Double door |
| 85 | 16way,Double door |
| 86 | S/F Modular type blanking plate :-Supplying and fixing modular blanking plate on the existing modular plate and switch box exculiding modular plate etc.as requried. |
| 87 | S/F SP MCB blanking plate :-Suppling and fixing Single pole blanking plate inexisting MCB DB complete etc. as required . |
| 88 | 400 amps, TP&N, HRC |
| 89 | 400 amps, 4 pole |
| 90 | 400 amps |
| 91 | 200 amps, TP&N, HRC |
| 92 | 4way (4+12), Single door,Horizontal type |
| 93 | 50/63 amps TPN |
| 94 | 16 amps, double pole |
| 95 | Copper earth plate electrode:-Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclours with cover plate having locking arrangrment and watering pipe etc .as requried .(But with out charcoal or coke and salt). |
| 96 | S/L 8 SWG copper wire in ground:-Suppling and laying 8SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldring as requried. |
| 97 | S/L 25mm x6mm G.I. earth strip in ground :-Supplying and laying 25mm x6mm G.I. strip at 0.50 metre below ground as strip earth eletrode, incoluding soldering etc .as requried. |
| 98 | P/F G.I lighting conductor finial :-Providing and fixing of lighting conductor finial, made of 25 mm dia 300mm long, G.I tube, having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc as rqquried. |
| 99 | Reverting sweating and soldring lighting conductor tape:-Reverting sweating and soldring of copper / G.I tape (with another copper/ G.I tape, base of the final or any another metalic object) as requried. |
| 100 | P/F G.I lighting conductor tape in vertical run :-Providing and fixing G.I tape 20 mm x 3 mm thick on parapet or surface of wall for lighting conductor complete as requried.( for horizontal run ). |
| 101 | P/F Testing joint for G.I lighting conductor :-Providing and fixing testing joint, 20 mm x 3 mm thick copper strip 125 mm long , with 4 nos. of G.I bolts, nuts, check nuts and spring washers etc. complete as requried. |
| 102 | P/F coppre earth tape for lighting conductor :-Providing and laying copper tape 32 mm x 6 mm from earth electrode directly in ground as requried. |
| 103 | S.LT.C of floowing rating LED Street lighting luminarie wa pressure die cast housing and toughened glass cover IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to 15. 10322 part-5/section-3 and shall be complete with all necessary accessories as required 120W LED Street light |
| 104 | Cement |
| 105 | Steel |
| 106 | Stone Chips |
| 107 | Red Brick |
| 108 | Fly Brick |
| 109 | GST @ 18% |
| 110 | Labour cess @ 1% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysSep 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender