Tender For Permission For Shifting And Re-Erection Of Existing Electrical Infrastructure At Sikharapur To Pratappur Due To Improvement Of Patapur-Bhabandha Road From 0/0 To 3/813 Km
Tender Value
9.69 Lakhs
Estimated cost
Bid Submission
22 Sep 2026
6 days left
EMD
9700
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ganjam → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Permission For Shifting And Re-Erection Of Existing Electrical Infrastructure At Sikharapur To Pratappur Due To Improvement Of Patapur-Bhabandha Road From 0/0 To 3/813 Km
BOQ
| Sl. No. | Item Description |
| 1 | Shifting and Re-erection of 11KV 3P, 3W HTOH line with 55mmsq AAA Conductor over 04Nos. 11Mtr. long 160X152mm WPB pole and over 02Nos.10Mtr long 330Kg. PSC pole = 0.06Ckm. wirh 02Nos. road crossing cadrle guarding, 02Nos. 11KV Cut points with dismantling of 06Nos. HT PSC Poles. - 10mtr long 330kg PSC pole |
| 2 | WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate300x300xl2 |
| 3 | Earthing Of Support (Coil Type) |
| 4 | RCC Base plate for support |
| 5 | 55mm2 All Alloy Aluminum Conductor.AAAC |
| 6 | 11KV V-Cross arm (10.2 Kg ) GI |
| 7 | GI Back Clamp for V Cross Arm (0.85 Kg ) |
| 8 | 11 KV F clamp 2.9 Kg |
| 9 | Top Bracket 100X50mm Gl channel (02 Kg each) |
| 10 | 100X50X6mm. MS Channel for straight cross arm (1.2m X 6 pcs)on each pole (9.2Kg/mtr.) for tapping & cut point pole+ Galvanisation charges |
| 11 | 11KV Disc insulator (T& C) 45 KN, Polymer |
| 12 | 11KV H/Wfitting (T & C) type ,45 KN |
| 13 | 11KV Pin insulator Polymer |
| 14 | H.T Stay set (Complete) |
| 15 | Stay Insulator |
| 16 | Stay clamp or Stud Clamp |
| 17 | 7/10 SWG stay wire |
| 18 | No.6 G.I wire for (Dia-4.8mm)(0.182Kg/mtr) Guarding |
| 19 | No.8 G.I wire for cross lacing(0.131Kg/mtr) |
| 20 | No.10 G.I wire for cross lacing binding (0.08Kg/mtr) (2F/lacing * 40 /3.28) for Guarding) |
| 21 | No.6 G.I wire for Guarding earthing |
| 22 | 75X40X6mm. MS Channel for straight cross arm (1.5m X8 pcs) (6.8Kg/ mtr.) + Galvanisation charges for 01Nos. Guarding |
| 23 | G.I Pipe Earthing 40mm Dia medium gauge 3mtr long for Earthing device for guarding ' |
| 24 | Eye hook |
| 25 | Danger Board |
| 26 | GI Clamp for Danger Board GI Flat(25X3 &0.6 Kg/Mtr) 510mm length(0.306 Kg/Piece) |
| 27 | G.I Barbed Wire anticlimbimg device 3. kg per support |
| 28 | GI clamp for anti Climbing Devicev25X3 mm Flat (0.6 Kg/Mtr) Flat of 0.510 Mtr Length |
| 29 | GI Nut,Bol & washer |
| 30 | Sundries to complete the job etc |
| 31 | Stay/Strut Pole concreting in ratio 1:2:4 (0.5x0.5x0.8) = 0.2Cu.mtr . |
| 32 | Concreting of poles in ratio 1:1.5:3 (500mmX500mmX 1800mm) = 0.45Cu.mtr (11mtr WPB/RS Joist/ H Pole) |
| 33 | Concreting of poles in ratio 1:1.5:3 (500mmX500mmX1660mm) = 0.415Cu.mtr (l0mtr PSC/RS Joist Pole) |
| 34 | Couping of poles in ratio 1:1.5:3= 0.1125 Cu mtr |
| 35 | Materials for masonary work for earth pit Charcoal, salt etCfor earthing of guarding |
| 36 | Dismantaling of 11KV HT PSC pole= 06Nos. |
| 37 | Shifting and Re-erection of LTOH line by using (4X50+1X50*1X16)mmsq AB Cable = 0.06Ckm. and (2X35+1X35)mmsq AB Cable = 0.05Ckm. over 04Nos. 9Mtr. long 300Kg. PSC poles & over 02Nos. 08Mtr. long 200Kg. PSC poles with dismantling of LT PSC poles 05Nos. - 8Mtr long 200Kg PSC Pole |
| 38 | 9Mtr long 300Kg PSC Pole |
| 39 | Lt Stay Set |
| 40 | LT Stay Insulator |
| 41 | LT Stay Clamp (1.4 Kg/pair) |
| 42 | 7/10 SWG Stay Wire Grade-2 |
| 43 | AB CABLE (2X35+1X35) MMSQ |
| 44 | AB CABLE (4X50+1X50+1X16) MMSQ |
| 45 | RCC Base plate for support |
| 46 | Earthing Of Support (Coil Type) |
| 47 | LT Distribution Box Polycarbonate |
| 48 | Pole clamp for eye hook for XLPE /AB Cable |
| 49 | Conductor dead end clamp for baie massenger XLPE / ABC (25-70 sqmm) |
| 50 | Suspension clamp with eye hook for ABC |
| 51 | Insulated Piercing connector Type A main 16 to 95 sqmm tap -16 to 95 sqmm |
| 52 | Neutral connector Type B suitable for main 35-70 sqmm AAAC & TAP -2.5 to 10 sqmm service cable cover by black weather resistant insulation cover |
| 53 | Danger Board |
| 54 | G.I Clamp for Danger Board GI Flat(25X3 @0.6 Kg/Mtr) 510 mm length(0.306 Kg/Piece) |
| 55 | G.I Barbed Wire anticlimbimg device 3. kg per support |
| 56 | GI clamp for anti Climbing Device 25X3 mm Flat (0.6 Kg/Mtr) Flat of 0.510 Mtr Length |
| 57 | GI Bolts Nuts and washers |
| 58 | Sundries to complete the job etc. |
| 59 | Stay concreting in ratio 1:2:4 (0.5x0.5x0.8)mtr .(a) |
| 60 | Concreting of poles in ratio 1:1.5:3(500mmX500mmX1500mm) = 0.375Cu.mtr(b) |
| 61 | Couping of poles in ratio 1:1.5:3 (500X500X475)= 0.11875 Cu mtr |
| 62 | Dismantaling of LT PSC pole= 05Nos. |
| 63 | PART - I. Estimate and cost of materials for Shifting and Re-erection of 11KV 3P, 3W HTOH line with 55mmsq AAA Conductor over 04Nos. 11Mtr. long 160X152mm WPB pole and over 02Nos.10Mtr long 330Kg. PSC pole - 0.06Ckm. wirh 02Nos. road crossing cadrle guarding, 02Nos. 11 KV Cut points with dismantling of 06Nos. HT PSC Poles. - 10mtr long 330kg PSC pole |
| 64 | WPB 160x152 (30.44KG/Mtr.),11 mtr- with base plate 300x300xl2 |
| 65 | Earthing Of Support (Coil Type) |
| 66 | RCC Base plate for support |
| 67 | 55mm2 All Alloy Aluminum Conductor AAAC |
| 68 | 11KV VCross arm (10.2 Kg) GI |
| 69 | GI Back Clamp for V Cross Arm (0.85 Kg ) |
| 70 | 11 KV F clamp 2.9 Kg |
| 71 | Top Bracket 100X50mm Gl channel (02 Kg each) |
| 72 | 100X50X6mm. MS Channel for straight cross arm (1.2m X 6 pcs)on each pole (9.2Kg/mtr.) for tapping & cut point pole+ Galvanisation charges |
| 73 | 11KV Disc insulator (T& C) 45 KN, Polymer |
| 74 | 11KV H/Wfitting (T & C) type ,45 KN |
| 75 | 11KV Pin insulator Polymer |
| 76 | H.T Stay set (Complete) |
| 77 | Stay Insulator |
| 78 | Stay clamp or Stud Clamp |
| 79 | 7/10 SWG stay wire |
| 80 | No.6 G.I wire for (Dia-4.8mm)(0.182Kg/mtr) Guarding |
| 81 | No.8 G.I wire for cross lacing(0.131Kg/mtr) |
| 82 | No.10 G.I wire for cross lacing binding (0.08Kg/mtr) (2F/lacing * 40 /3.28) for Guarding) |
| 83 | No.6 G.I wire for Guarding earthing |
| 84 | 75X40X6mm. MS Channel for straight cross arm (1.5m X8 pcs) (6.8Kg/ mtr.) + Galvanisation charges for 01Nos.Guarding |
| 85 | G.I Pipe Earthing 40mm Dia medium gauge 3mtr long for Earthing device for guarding |
| 86 | Eye hook |
| 87 | Danger Board |
| 88 | GI Clamp for Danger Board GI Flat(25X3 &0.6 Kg/Mtr) 510mm length(0.306 Kg/Piece) |
| 89 | G.I Barbed Wire anticlimbimg device 3. kg per support |
| 90 | GI clamp for anti Climbing Devicev25X3 mm Flat (0.6 Kg/Mtr) Flat of 0.510 Mtr Length |
| 91 | G.I Nut,Bol & washer |
| 92 | Sundries to complete the job etc |
| 93 | Stay/Strut Pole concreting in ratio 1:2:4 (0.5x0.5x0.8) =0.2Cu.mtr . |
| 94 | Concreting of poles in ratio 1:1.5:3 (500mmX500mmX 1800mm) = 0.45Cu.mtr (11mtr WPB/RS Joist/ H Pole) |
| 95 | Concreting of poles in ratio 1:1.5:3 (500mmX500mmX1660mm) = 0.415Cu.mtr (10mtr PSC/RS Joist Pole) |
| 96 | Couping of poles in ratio 1:1.5:3 = 0.1125 Cu.Mtr |
| 97 | Materials for masonary work for earth pit Charcoa1,saIt etc for earthing of guarding |
| 98 | Dismentaling of 11KV HT PSC Pole= 06 Nos |
| 99 | PART -II:- Shifting and Re-erection of LTOH line by using (4X50+1X50+lX16)mmsq AB Cable = 0.06Ckm. and (2X35+1X35)rnmsq AB Cable = 0.05Ckm. over 04Nos. 9Mtr. long 300Kg. PSC poles & over 02Nos. 08Mtr. long 200Kg. PSC poles with dismantling of LT PSC poles 05Nos. - 8Mtr long 200Kg PSC Pole |
| 100 | 9Mtr long 300Kg PSC Pole |
| 101 | Lt Stay Set |
| 102 | LT Stay Insulator |
| 103 | LT Stay Clamp (1.4 Kg/pair) |
| 104 | 7/10 SWG Stay Wire Grade-2 |
| 105 | AB CABLE (2X35+1X35) MMSQ |
| 106 | AB CABLE (4X50+1X50+1X16) MMSQ |
| 107 | RCC Base plate for support |
| 108 | Earthing Of Support (Coil Type) |
| 109 | LT Distribution Box Polycarbonate |
| 110 | Pole clamp for eye hook for XLPE /AB Cable |
| 111 | Conductor dead end clamp for baie massenger XLPE/ABC (25-70 sqmm) |
| 112 | Suspension clamp with eye hook for ABC |
| 113 | Eye hook for conductor dead end clamp |
| 114 | Insulated Piercing connector Type A main 16 to 95 sqmm O tap - 16 to 95 sqmm |
| 115 | Neutral connector Type B suitable for main 35-70 sqmm AAAC & TAP -2.5 to 10 sqmm service cable cover by black weather resistant insulation cover |
| 116 | Danger Board |
| 117 | GI Clamp for Danger Board GI Flat(25X3 fl0.6 Kg/Mtr) 510 mm length(0.306 Kg/Piece) |
| 118 | G .I Barbed Wire anticlimbimg device 3. kg per support |
| 119 | GI clamp for anti Climbing Devicev25X3 mm Flat (0.6 Kg/Mtr) Flat of 0.510 Mtr kength |
| 120 | GI Bolts Nuts and washers |
| 121 | Sundries to complete the job etc. |
| 122 | Stay concreting in ratio 1:2:4 (0.5x0.5x0.8)mtr .(a) |
| 123 | Concreting of poles in ratio 1:1.5:3(500mmX500mmX1500mm) = 0.375Cu.mtr(b) |
| 124 | Couping of poles in ratio 1:1.5:3 (500X500X475)= 0.11875 C mtr@ |
| 125 | Dismantaling of LT PSC pole= 05Nos. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender