Public Administrative Department Local Bodies Closing in 19 days TDR #57501284

Tender For Construction And Interior Work For Nirupankar Tirtharup Appasaheb Dharmadhikari Auditorium On An Amenity Plot At Waghbil Within The Thane Municipal Corporation Area.

Issued by Local Bodies · Thane, Maharashtra
Tender Value
196.38 Crore
Estimated cost
Bid Submission
05 Oct 2026
19 days left
EMD
98.19 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thane → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction And Interior Work For Nirupankar Tirtharup Appasaheb Dharmadhikari Auditorium On An Amenity Plot At Waghbil Within The Thane Municipal Corporation Area.

BOQ

Name of Work:- Construction and interior work for Nirupankar Tirtharup Appasaheb Dharmadhikari Auditorium on an amenity plot at Waghbil within the Thane Municipal Corporation area.
Sl. No. Item Description
1Excavation for foundation in earth, soil of all types, sand, gravel and soft murum,including removing the excavated material up to a distance of 50m. beyond thebuilding area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming,watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
2Excavation for foundation in earth, soils of all types, sand,gravel and soft murum,including removing the excavated material upto a distance of 50metres beyond thebuilding area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means
3Excavation for foundation in earth, soils of all types, sand,gravel and soft murum,including removing the excavated material upto a distance of 50metres beyond thebuilding area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete.Excavation Beyond 3.00m : Depth From 3.0 m to 4.50 m depth add 20 %
4Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 m to 3.0 m.) By Mechanical Means- Excavation Beyond 4.50m :4.50 m to 6.00 m depth add 30 %
5Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means- Excavation Beyond 6.00m : Below 6.00 m to 7.50 depth add 40 %
6Excavation Beyond 7.50m : Below 7.50 m to 9.00 depth add 50 %
7Excavation Beyond 9.00m : Below 9.00 m to 10.50 depth add 60 %
8Excavation Beyond 10.50m : Below 10.50 m to 12.00 depth add 70 %
9Excavation Beyond 12.00m : Below 12.00 depth add 80 %
10Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete.
11Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete.
12Carting away unwanted excavated material such as soil, lime, moorum, building rubbish (including RCC debris, masonry debris , laterite stone, ordinary rock, boulders etc.) from the site to a disposal location arranged by the contractor at his own cost, for all leads and lifts, including loading, transportation by mechanical automotive means, unloading, and all incidental charges; the contractor shall obtain all necessary statutory approvals for disposal. Distance Upto 20Km.
13Dewatering the excavated trenches/pits, pools of water, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge including cost of machinery, labour, fuel, pipe and it's accessories etc. complete. Note : This item will be operated/executed with the prior specific sanction of the Head of department.
14Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete
15Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
16Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/granite/quartzite/gneiss metal for R.C.C.coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including steel centering, formwork, cover blocks, laying/pumping, compacting ,curing , finishing androughening them if special finish is to be provided and curing complete. (Excludingreinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible DrumType mixer/ concrete Batch mix plant (Pan mixer) etc. complete.Withfineaggregate (Crushed sand VSI Grade- Basement to Ground floor
171st Floor
182nd Floor
193rd Floor
204th Floor
215th Floor
22Terrace Floor
23Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. columns as per detailed designs and drawing or as directed including Steel centering formwork, cover blocks laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)
24Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap / granite/quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)- Basement to Ground floor
251st Floor
262nd Floor
273rd Floor
284th Floor
295th Floor
30Terrace Floor
31Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap /granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)- Basement to Ground floor
321st Floor
332nd Floor
343rd Floor
354th Floor
365th Floor
37Terrace Floor
38Providing and laying Cast in situ/Ready Mix cement concrete M-40 of trap/granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)- Basement to Ground floor
391st Floor
402nd Floor
413rd Floor
424th Floor
435th Floor
44Terrace Floor
45Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)- Basement to Ground floor
461st Floor
472nd Floor
483rd Floor
494th Floor
505th Floor
51Terrace Floor
52Providing and laying Cast in situ/Ready Mix cement concrete in M-40 of trap / quartzite /granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade)- Basement to Ground floor
531st Floor
542nd Floor
553rd Floor
564th Floor
575th Floor
58Terrace Floor
59Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 mm wide and 20 mm deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) etc. complete with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc.complete.
60Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of shuttering and de-centering at all levels, over a height of 4.5m.Plan Area will be Payable Only
61Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) barreinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs,beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins,arches etc. as per detailed designs,drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.- Basement to Ground floor
621st Floor
632nd Floor
643rd Floor
654th Floor
665th Floor
67Terrace Floor
68Design & Execution of Post Tensioning Slab & Beam with Supply, assembly, installation and profiling of all post tensioning tendons includings laying of HT strands, PVC Sheathing jointing with couplers and inserting the strands , profiling, fixing live end anchorages, including fixing tendons support bars with all hardware, stressing of all tendons with equipments and skilled manpower, Stressing anchorage, cement grouting of all tendons with equipments and skilled manpower, designing of post tensioned slab and beams as per IS : 1343 for bonded system as per layout issued by Consultants, getting design approved from Consultant, preparation of as built drawings for PT slabs and beams at all levels and lifts. Contractor should quote the rate considering Silica Grout to be used as a grouting material (only Cement - additive Grout) & stressing ends to be protected. Only Plan area of slab will be measured for payment.
69Providing and laying in-situ Light weight foam concrete of density 1000 kg/m³ using OPC cement, foaming agent, water, and sand (if required) (as per design) for filling, slope formation, or void filling under the auditorium flooring. Rate including centering, formwork, mixing, pumping, placing in position, leveling & finished with required slopes/levels, curing, and all leads and lifts complete as per specifications and drawings.
70Providing & filling cinder/AAC blocks or any such similar light weight material at any lead & level incl. watering, consolidating , top surface dressed and levelled to proper gradient etc.complete as per direction of engineer incharge.
71Finishing upto 225 mm thick cement concrete laid to proper level and slope including compacting finishing with tremix treatment for paving slab with compaction by screed vibrator, removing excess water from the cement concrete by tremix vaccum dewatering system , finishing the surface with floater and trowel including all etc. complete as directed
72Providing and laying plum concrete in cement concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded granitic or basaltic stone aggregate 40 mm nominal size) with plums not exceeding 40% of the volume of the finished concrete of size ranging from 150 to 300 mm (but the maximum dimension not exceeding 1/3rd (one third) the least dimension of member under consideration excluding the cost of centering and shuttering with hard stone plum for retaining wall including required weep holes with PVC pipe at 1m c/c in staggered way, scaffolding / staging, raking out joints, curing, levelling course at bottom in all conditions etc. complete as per drawing and specifications, and as directed by the Engineer.
73Centering and shuttering of steel plates with M.S. Angles including strutting, propping etc. and removal of form for : Walls (any thickness) including attached butteresses,,retaining wall, shear wall, diaphragm wall etc
74Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in Half brick thick wall including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)
75Providing Autoclaved Aerated Concrete Block masonary of conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)- Basement to Ground floor
761st Floor
772nd Floor
783rd Floor
794th Floor
805th Floor
81Terrace Floor
82Providing fly ash brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete- Basement to Ground floor
831st Floor
842nd Floor
853rd Floor
864th Floor
875th Floor
88Terrace Floor
89Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Sq.m of surface area covering ten years guarantee on bond paper.
90Providing and laying 10 to 13mm thk. heavy duty,scratch resistant, high abrasion resistant vitrified tiles (Durastone of equivalent) conforming to I.S.15622 with special hard wearing layer and water absorbtion less than 0.08% for flooring of an approved, quality,make, pattern and size for flooring including cement mortar bedding of 25 mm thick in 1:4 proportion,cutting, leveling, jointing, filling the joints by neat cement slurry or approved colour grout, curing, finishing etc complete as directed by Engineer In Charge.Size of Tile-600mm X1200mm
91Providing and fixing 9 to 10 mm thk. vitrified tiles as specified below conforming to I.S. 15622-2006 of approved quality, pattern and colour for flush/projected skirting and risers including preparing the surface and levelling in the desired line, backing of 20 thk. cement mortar in porportion 1:3, square cut top edge or chamfered top edge in cement mortar 1:3, cement float, machine cutting, leveling, jointing, filling the joints with neat cement slurry or pigments mixed with cement, finishing, curing etc complete as directed by Engineer In ChargeSize of Tile-600mm X1200mm- Light coloured glazed vitrified tiles for height upto 150mm
92Dark coloured glazed vitrified tiles for height upto 150mm
93Providing and laying Full Boby vitrified antiskid type tiles of size 600 mm x 1200 mm and 10 mm thick having water absorption within 0.1% to 0.5% and conforming to IS Code 15622 of approved make, shade and pattern for flooring bedded in cement mortar mix in ratio of 1:6 (1 cement : 3 natural sand :3 crushed sand) including cleaning and preparing the surfaces for bedding in required thickness (should be more than 20 mm ) , spreading neat cement slurry using minimum cement about 2 Kg./Sqm.. over cleaned surface and spreading neat cement paste using minimum cement about 4.5 Kg. / Sqm. over cement mortar bed, pointing/grouting with white or color cement or approved chemical grout, required adhesive for fixing on metal surface, required spacers, cleaning, curing protection of tiles etc. All works complete as per the drawing, specification & tender drawing and direction of the Engineer.
94Providing and laying Full Boby vitrified Glossy finish decorative type tiles of size 600 mm x 1200 mm and 10 mm thick having water absorption within 0.1% to 0.5% and conforming to IS Code 15622 of approved make, shade and pattern for Skirting , dado in required position laid on a required thickness of back coat in cement mortar 1:3 to correct line (should be more than 20 mm) , level and plumb including neat cement float, pointing / grouting with white or color cement or approved chemical grout, required spacers, curing, cleaning and protection of tiles etc. All works complete as per the drawing, specification & tender drawing and direction of the Engineer.
95Providing and fixing 18mm thick Polished Italian Marble Flooring of approved colour and approved texture in rich mix cement mortar bedding including surface preparation, giving necessary slopes, cleaning joints and grouting them in white cement paste with pigmented addhessives to match shade of the marble. The rate includes costs of all materials, equipments, labour charges, curing, rubbing, washing, cleaning the surface etc. Complete as per specification & as directed by Engineer-in-charge.
96Providing and fixing 18mm thick Polished Italian Marble for Skirting , dado in required position laid on a required thickness of approved colour and approved texture in rich mix cement mortar bedding including surface preparation, giving necessary slopes, cleaning joints and grouting them in white cement paste with pigmented addhessives to match shade of the marble. The rate includes costs of all materials, equipments, labour charges, curing, rubbing, washing, cleaning the surface etc. Complete as per specification & as directed by Engineer-in-charge.
97Providing and laying machine cut machine Polished Kota stone flooring 25mm to 30mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.- Basement to Ground floor
981st Floor
992nd Floor
1003rd Floor
1014th Floor
1025th Floor
103Terrace Floor
104Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete- Basement to Ground floor
1051st Floor
1062nd Floor
1073rd Floor
1084th Floor
1095th Floor
110Terrace Floor
111Providing and laying Full Boby vitrified antiskid type tiles of size 600 mm x 600 mm and 10 mm thick having water absorption within 0.1% to 0.5% and conforming to IS Code 15622 of approved make, shade and pattern for flooring bedded in cement mortar mix in ratio of 1:6 (1 cement : 3 natural sand :3 crushed sand) including cleaning and preparing the surfaces for bedding in required thickness (should be more than 20 mm ) , spreading neat cement slurry using minimum cement about 2 Kg./Sqm.. over cleaned surface and spreading neat cement paste using minimum cement about 4.5 Kg. / Sqm. over cement mortar bed, pointing/grouting with white or color cement or approved chemical grout, required adhesive for fixing on metal surface, required spacers, cleaning, curing protection of tiles etc. All works complete as per the drawing, specification & tender drawing and direction of the Engineer.
112Providing and laying Full Boby vitrified Matt/Glossy finish decorative type tiles of size 600 mm x 600 mm and 10 mm thick having water absorption within 0.1% to 0.5% and conforming to IS Code 15622 of approved make, shade and pattern for Skirting , dado in required position laid on a required thickness of back coat in cement mortar 1:3 to correct line (should be more than 20 mm) , level and plumb including neat cement float, pointing / grouting with white or color cement or approved chemical grout, required spacers, curing, cleaning and protection of tiles etc. All works complete as per the drawing, specification & tender drawing and direction of the Engineer.
113Providing and fixing polished natural stone tiles as specified below of approved quality, diffrent floor patterns as per approved drawings and colour for inlay flooring including preparing the surface and levelling in the desired line, backing of 20 mm thk. cement mortar in porportion 1:3, square cut top edge or chamfered top edge, grooving, moulding etc in cement mortar 1:3, cement float, machine cutting, leveling, jointing, filling the joints with neat cement or pigment mixed with cement, polishing, finishing, curing etc complete as directed by Engineer In Charge.(Gangsaw Granite or Equivalent)
114Providing and fixing telephone black finished Granite as specified below of approved quality, pattern and colour for Flooring including preparing the surface and levelling in the desired line, backing of 20mm thk. cement mortar in porportion 1:3, square cut top edge or chamfered top edge, grooving, moulding etc in cement mortar 1:3, cement float, machine cutting, leveling, jointing, filling the joints with neat cement or pigment mixed with cement, polishing, finishing, curing etc complete as directed by Engineer In Charge.
115Providing and fixing polished natural stone tiles /slab as specified below of approved quality, pattern and colour for flush/projected skirting and risers including preparing the surface and levelling in the desired line, backing of 20 thk. cement mortar in porportion 1:3, square cut top edge or chamfered top edge in cement mortar 1:3, cement float, machine cutting,leveling, jointing, filling the joints with neat cement or pigment mixed with cement, polishing, finishing, curing etc complete as directed by Engineer In Charge. - 15 to 20 mm thk. Ruby red, jet black, Hasan green Granite tiles/slab for height upto 150 mm
116Providing and laying telephone black / Amba White / Cadburybrown /Ruby red / Ocean Brown / approved granite stone grade 1 of 20 to 22 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
117Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.- Basement to Ground floor
1181st Floor
1192nd Floor
1203rd Floor
1214th Floor
1225th Floor
123Terrace Floor
124Providing and fixing machine cut mirror polished 20 mm to 22 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown / approved granite stone grade 1 partition with full moulding the edges etc. complete . Both side mirror polish
125Providing sills of required material 20mm to 25mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing,cleaning complete. b) Granite grade 1
126Providing and fixing machine cut machine polished 20 mm to 22 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown/ approved granite stone grade 1 for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
127Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
128Providing leather finished polishing to Kota / Marble / Shahabad / Kadappa Stone slab by continuous grinding in 4 coats of different bits to receive rough and matty finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.- Basement to Ground floor
1291st Floor
1302nd Floor
1313rd Floor
1324th Floor
1335th Floor
134Terrace Floor
135Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 80MM thick in M-40 grade of approved size and shape for City streets, small /medium market roads,low volume roads, utility cuts on arterial roads etc. as specified and as per IS15658:2006 including cost of all materials,manufacturing,curing, transportation of blocks to work site including loading, unloading and stacking as directed, laying paving blocks in position over prepared bed of natural sand/ crushed sand of 50mm thickness including necessary excavation in all stratas,spreading blindge of fines and over the prepared bed,compacting blocks by plate vibrator etc. complete.
136Providing and fixing factory made Hydraulically pressed Mechanically vibrated and compacted precast inter locking cement concrete paving blocks 100MM thick in M-50 grade of approved size and shape for City streets and roads with high volume/ heavy traffice as specified and as per IS 15658:2006 including cost of all materials, manufacturing, curing, transportation of blocks to work site including loading, and stacking as directed, laying paving blocks in position over prepared bed of natural sand / crushed sand of 50 mm thickness including necessary excavation in all stratas,spreading blindge of fine sand over the prepared bed, compacting blocks by plate vibrator etc. complete.
137Providing and laying heavy-duty car parking tiles of 40mm thickness (cement/concrete/chequered), size 300x300mm or 400x400mm, of approved color, design, and manufacturer. The tiles are to be laid over a 20mm average thick cement mortar bed (1:4), finished with neat cement slurry. Jointing shall be done with white cement or approved color pigment. The rate includes cost of all materials, curing, cutting, and wastage.
138Providing and laying machine-cut, polished sandstone flooring of approved quality, color, and texture (e.g., Agra Red, Beige, Mint, or Dholpur Pink) of 25mm thickness, over an average 25mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand). Joints to be filled with white cement mixed with pigment to match the shade of the stone. Flooring finished with fine rubbing/polishing, curing, etc., complete as per instructions of the Engineer-in-Charge.
139Providing and laying machine-cut, sand blasted sandstone flooring of approved quality, color, and texture (e.g., Agra Red, Beige, Mint, or Dholpur Pink) of 25mm thickness, over an average 25mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand). Joints to be filled with white cement mixed with pigment to match the shade of the stone. Flooring finished with fine rubbing/polishing, curing, and full moulding and three grooved line for the treads etc., complete as per instructions of the Engineer-in-Charge.
140Providing and fixing of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand as per the direction of engineer in charge.- Basement to Ground floor
1411st Floor
1422nd Floor
1433rd Floor
1444th Floor
1455th Floor
146Terrace Floor
147Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.- Basement to Ground floor
1481st Floor
1492nd Floor
1503rd Floor
1514th Floor
1525th Floor
153Terrace Floor
154Providing and applying gypsum plaster (with Gypsum material )with finishing with gypsum material in10 to 13 millimeter thickness to previously plastered surface/or on newly brick surface (Excluding rough cast plaster)in all position including preparing and Finishing the surface scaffolding etc.complete.- Basement to Ground floor
1551st Floor
1562nd Floor
1573rd Floor
1584th Floor
1595th Floor
160Terrace Floor
161Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
162Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete. (Excluding Tiles) (As directed by Engineer in Charge)- Basement to Ground floor
1631st Floor
1642nd Floor
1653rd Floor
1664th Floor
1675th Floor
168Terrace Floor
169Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete.- Basement to Ground floor
1701st Floor
1712nd Floor
1723rd Floor
1734th Floor
1745th Floor
175Terrace Floor
176Providing and applying Royale/Velvet Touch paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete
177Providing and applying three coats of White/colour wash to any surface with lime wash prepared from quick lime of best quality by adding blue/colour pigments and glue of approved colour, quality in required quantities at all height and locationsas directed including scaffolding, cleaning and preparing surfaces for painting with broom, coir and sand paper if necessary or by any other approved means etc. complete as directed by Engineer-in-charge.
178Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.- Basement to Ground floor
1791st Floor
1802nd Floor
1813rd Floor
1824th Floor
1835th Floor
184Terrace Floor
185Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete.
186Providing and applying Textured paint of approved texture and colour for External walls/surfaces which includes preparing the surface, applying primer, putty & paint to 2-3 number of coats to achieve desired texture & applying protective coat to give a finish acceptable to the engineer and any additional coats if required shall be at the cost of the contractor, as per manufacturers specification and technical manual including required cleaning of the surfaces, curing etc. complete to the entire satisfaction of the Engineer. Rate shall be inclusive of surface preparation to line & level with all necessary tools & tackles, etc. maintaining proper line, level and grooves at all height including the necessary scaffolding, curing, cleaning of floor etc complete. to the satisfaction of Engineer-in-charge. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
187Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works.- Basement to Ground floor
1881st Floor
1892nd Floor
1903rd Floor
1914th Floor
1925th Floor
193Terrace Floor
194Waterproofing Treatment to new Toilet/ bathroom by using Polymeric Cementitious Membrane as approved by Engineer in charge, followed by 112mm thick brick bat coba covered with 20 mm mortar finish. If there are cracks on the bare slab, open the crack in V Groove and fill it with ready to use repair polymer modified mortar based on special cements, aldehyde based polymers with thixotropy modifying agents. If there are lots of honeycombs and identified bad patches of concrete the same should be grouted as per the instructions of site incharge. (The grouting shall be paid separately). Clean the entire surface thoroughly and over this prepared surface, apply three coats of polymeric Cementitious waterproofing coating having a non-toxic, 2-(methoxycarbonyl)-1-propene Butyl-2 propenoate (MPBP) based polymeric waterproofing solution as approved by Engineer in charge. Provide and lay 112 mm average thicknes of brick bat coba in cement mortar 1:5 over 12mm thick CM 1:3 bedding with one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents as approved by Engineer in charge per 50 Kg bag of cement and finishing with 20 mm thick cement plaster in cement mortar 1:3 by mixing one 330 grams pouch of above admixture per 50 Kg bag of cement, including all lead, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of wall and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatement with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment.- MPBP Polymeric Waterproofing Coating for Concrete and Masonry should have following minimum properties:1) Elongation % (ASTM D412-2016): @ 100% 2) Tensile Strength N/mm2 (ASTM D412- 2016): 3.3 3) Specific Gravity: 1.02 ± 0.02 4) Total Solids (ASTM D1644-2012): 43.98 5) Hardness Shore A (ASTM D2240-2015): 82 - Basement to Ground floor
1951st Floor
1962nd Floor
1973rd Floor
1984th Floor
1995th Floor
200Terrace Floor
201Providing waterproofing treatment through specialized agencies as per their specifications to the flooring of water closets, bathrooms, kitchen, nahanies, washing places, sanitary blocks etc. by giving INJECTIONS with cement solution with water proofing compound into the floor slab so as to make it consistent, homogeneous and impervious against leakage, seepage etc. The sunk portion shall then be covered with brickbat waterproof coba in 1:5 c.s. of required thickness with necessary gradient for easy flow of water. Finally the floor shall be covered with joint less waterproof cement plaster in 1:3 c.s. 12 mm to 15 mm thick finished rough for receiving tiles. The average thickness of complete treatment shall not be less than 100 mm. The soil pan area will not be deducted. ( After completion of work leakage test shall be carried out after impounding the water for 7 days without any extra cost. The actual treated area will be measured and paid for).
202Extra for providing additional thickness of brickbats over 100 mm in 1:5 c.s. either due to location of rain water pipes or due to increase in the travel length of flow of rain water or brick bats required in the sunk portion of baths, W.C.s nahani etc. The rate includes for fixing brickbats in C.M., with waterproofing compound as per specification as directed.
203Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.- Basement to Ground floor
2041st Floor
2052nd Floor
2063rd Floor
2074th Floor
2085th Floor
209Terrace Floor
210Providing and installing crystalline waterproofing treatment to inside surfaces of the water retaining structures.VERTICAL SURFACES :a) Treatment shall consist of preparation of surfaces including ‘V’grooves at junctions and joints, pressure grouting the same and curing for specified period.b) Applying two coats of approved crystalline waterproofing compound at specified intervals as recommended by manufacturer and as directed by Engineer-in charge and allowed to cure.c) Extra for Plastering of walls and finishing smooth with 15 mm thick cement mortar 1:4 (1 cement : 4 fine sand) admixed with approved waterproofing compound in recommended proportions.HORIZONTAL SURFACES :d) Extra for Laying of 30 mm average thick cement concrete of mix 1:2:4 (1 cement : 2 coarse sand : 4 coarse aggregate of 12.5mm nominal size) admixed with approved waterproofing compound in recommended proportions, on floors to required gradient, including rounding of corners / junctions with walls and floors etc., and finished smooth and cured.Tank shall be tested by filling with water for required depth and maintaining it for 72 hrs. for checking the leakages. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma.
211Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 mm depth, filling the joints with 6 mm size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
212Providing and fixing 20to25mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25mm between rough shahabad and R.C.C.walls with cement grout mixed with waterproofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30to35mm and sloping coping over topmost tile with cement mortar1:3,butting the botto mmost with Cement concrete1:2:4mixed with water proofing liquid, curing, with 7years guarantee on court fee stamp of Rs.100/-with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
213Providing water proofing treatment to existing RCC overhead tank, basements, lift-pits and other underground structures. The treatment shall be done by giving INJECTIONS wherever necessary with waterproofing compound and cement solution as per tenderer‟s specifications into the floor & walls upto the full height of structures. All inherent holes, cavities, voids & honeycomb shall be filled up to make the structure consistent, homogenous resistant to water breakages, seepage, dampness and moisture etc. The floor shall then be treated with waterproofing metal coba of 30 mm to 35 mm thick in 1:4 C.S. mortar and walls with first coat of waterproofing plaster as per tenderer‟s specifications. Finally both floor and walls shall be finished smooth with jointless waterproofing plaster 1:3 C.S. 12 mm to 15 mm thick with water proofing materials as per tenderer‟s specifications in cement or finished rough to receive tile pavement or dado. The thickness of the treatment shall not be less than 50 mm to 60 mm for floors and 25 mm for walls. (The actual area of the
214Solid Core Flush door Single leaf- Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings, finishing with french-polish/ waxing complete. (without door frame). (Sample to be got approved from Ex.Engineer before use) Commercial Hard Wood shutter.- Basement to Ground floor
2151st Floor
2162nd Floor
2173rd Floor
2184th Floor
2195th Floor
220Terrace Floor
221Solid Core Flush door Double leaf- Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick marine grade block board core with teak wood lipping patti including french polish & approved veneers finish on both faces as per detailed drawings, conforming to I.S.: 2202 – 1966. All other necessary fittings and fastenings are matt finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc.
222Providing and fixing aluminum ventilators with aluminium with Anodizing frames 80 x 38 mm x 1.22 mm box type (including frame and shutter) with three partitions using 5mm thk frosted glass in one partition, Exhaust opening in one partition & 4 mm thk glass louvers in one partition with using weight and size of section not less then as required including sub frame (wherever required), locking arrangement, silicon sealant ,EPDM gaskets, including all aluminum fixture and fittings etc. complete . Rectangular tube @0.478kg/m
223Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete.
224Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 mm thick clear float glass etc. complete. Note While arriving at the rate of item of item weight at 6.90 Kilogram/ One Square Metre is considered. a) Colour anodized
225Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Rmt. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box.
226Providing and fixing of factorymade uPVC Sliding window & door (White Colour)complete,comprising uPVC multi-chambered frame having in-built uPVC roller track on top and uPVC sash with wall thickness of 2.3mm(+-0.2mm),duly reinforced withG.I. section 1.5mm,where ever required. uPVC window & door profile shall be made in India & shall conform to BSEN12608 and other standards as mentioned below: S.No.Name of the test Test Method Specified Parameter1TensileImpactStrength ISO8256-morethan 700Kj/m2 2VicatSoftening Temperature EN ISO – 306 Shall not be < 750C3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m24 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm25 Mean Breaking Stress for welded corner(a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2(b) For the compression bending test Shall not be < 30N/mm26 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 %7 Surface Spread of flame BS : 476 - Part 7 Classification 18 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable9 Tensile modulus ASTM D 638 Shall not be < 35 MPa10 Shear Modulus ASTM D 732 Shall not be < 220 MPa11 Tensile Strength EN ISO 527 Shall not be < 30 MPaAll corners of frame and sash will be Fusionwelded. After placing 5mm Float Annealed glass in the sash, uPVCglazingbead, interlock, EPDM/TPEgasket, brush shall be provided including touch lock and rollers & proper drainage system shall be provided.Window/Door will be fixed to the wall with 100 mm long and 8mm dia.Fasteners and complete in all respect as perd irection of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten(10) years against non-uniform discoloration, wrapping and rotting under general use.3 Track 3 / 6 Sash (Big Series) window frame of size 122 x 54 mm & Sash of size 64 x 47 mm - Basement to Ground floor
2271st Floor
2282nd Floor
2293rd Floor
2304th Floor
2315th Floor
232Terrace Floor
2333 Track 3 / 6 Sash (Big Series) window frame of size 122 x 54 mm & Sash of size 64 x 47 mm - Basement to Ground floor
2341st Floor
2352nd Floor
2363rd Floor
2374th Floor
2385th Floor
239Terrace Floor
240Providing and fixing mild steel grill work for windows, ventilators etc. 20 Kilogram/ One Sq.m as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
241Supply, fabrication, and installation of Double Glazed Unit (DGU) fixed window including required size of openable panel with Powder-coated aluminium section of 50 mm X 50 mm frame (min. 1.5 mm thickness) conforming to IS 733/1285 aluminium , consisting of 6 mm thick toughened clear glass inner side + 12 mm air gap (filled with dry air or argon gas) + 6 mm thick reflective toughened glass on External Side, sealed hermetically to form a DGU of approved make & shade. Aluminium spacer with desiccant, primary and secondary sealants with Silicone/Polyurethane based sealants as per ASTM standards. The unit shall be installed in powder-coated aluminum frame sections of minimum 1.5 mm thickness, Installed in prepared openings, EPDM rubber gaskets and pressure plates as required with necessary supports, packers, and sealants as per approved architectural drawings and specifications. Rate should be inclusive of Cost of glass, aluminum frame, all hardware, gaskets, sealants, flashing to ensure resistance to water penetration and air permeability, labor, scaffolding, transportation, and installation at all levels, all height complete in all respects. Vendor should provide Mockup & prototype for approval.
242Providing and Fixing mat finish stainless steel (of 304 grade ) railing with top pipe of 50 mm dia. and vertical pipe of 38 mm dia at 0.60 m c/c or as required and horizontal pipes of 25 mm dia in three rows, all pipes of 2 mm thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 mm dia above newel post of 75 mm diameter etc. complete (Prior approval of sample and brand )
243Providing and fixing MS. railing system (all type of railing , Grab bar , hand rail etc) modular in form, chemically passivated assembled with fittings made of Hollow tubes, channels, plates etc.with approved finish, including welding, grinding and making curvature (wherever required) and fitting the same with necessary nuts and bolts complete, i/c fixing the railing with necessary accessories & dash fasteners, bolts etc., of required size, on given surface with suitable arrangement as per approval of Engineer, (for payment purpose only weight of MS members shall be considered. All works complete as per the drawing, specification and direction of the Engineer. The hand railing and other horizontal members shall be bent to the correct radius shown on the drawings by appropriate means without losing the profile of the pipe. as directed by Engineer. MS railing shall be painted with one coat of Zinc Chromate Primer of total thickness of 35DFT. The railing shall be cleaned and applied Two Coats of Synthetic Enamel paint to provide minimum Dry Film thickness of 50 ± 5 micron for each coat. The interval between two coats should be 24 hours. Total paint thickness shall not be less than 150 micron DFT at any surface. The surfaces at connections (laps) shall receive both the coats properly at shop. Final touch up of same color shall be made after erection also.Rate should be inclusive of placing railing in proper position and in line embedded in concrete.
244Providing and fixing 1300mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 12mm thick toughened glass including fabricating ,fixtures, errecting, necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete
245Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.
246Telephone Black Granite Wash Hand Basin Counter : Providing and making wash basin counter in single piece of 18 mm to 20 mm thk. Telephone Black granite 600 mm side fixed over 25 to 40 mm thk. Black Cuddappa, stand with type construction,by making zari, in walls upto 75 mm deep & fitting the wall surface by C.M. 1:2 with necessary moulding,profile cutting in granite and cudappa including making hole to receive pillar cock for wash basin etc complete and as per detailed.
247Providing and constructing raised platform of 750 mm wide and 600 to 750mm high using minimum 40mm thick polished kadappa stone slab base with minimum 15mm thk. polished stone top as specified below of approved quality, colour and texture, supported by both side polished, 40mm thk. and minimum 700mm wide kadappa spaced at not more than 1200mm clear, including polished facia of min. 100mm height as specified below with champhered/ rounded at the top edges, jointing in approved adhesives, machine cutting, making opening for sink and fixing the same in position, leveling, smooth cement plastering along the sides to match the existing surface in cement mortar, filling the joints with pigment mixed with cement, cleaning, finishing, curing etc complete as directed by Engineer InCharge. (The cost of providing the sink shall be paid extra asper plumbing items)- Steel gray Granite granite slab at top and facia
248Providing and laying cement concrete flooring 50 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade
249Providing and fixing frame with/without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete- Basement to Ground floor
2501st Floor
2512nd Floor
2523rd Floor
2534th Floor
2545th Floor
255Terrace Floor
256Providing and fixing Second class teak wood moulded beading to doors frame and window frames with iron screws ,nails, adhesive , plugs etc with required french polish. All works complete as per the drawing, specification and direction of the Engineer.
257Providing and fixing fire doors with 2 hour fire rating conforming to IS: 3614 (Part 2), BS 476 (Parts 20 & 22), ISO 834 ; 45 mm thick fully flush, double skin door shell with lock seam joints at stile edges made from 1.25 mm thick galvanized steel sheet including door frames made from 1.6 mm thick galvanized steel sheet formed to double rebate profile of size 143 mm x 57mm as per manufacturer's instructions, door frames and shutter primed with Zinc Phosphate stoving Primer and finished with Polyurethane Aliphatic grade or epoxy paint including iron mongery consisting of stainless steel ball bearing butt hinges 3 mm thick fixed flush to the frame and shutter, full width horizontal handles (panic bar), concealed flush bolts, door closers, other standards fixtures and fasteners, etc. complete for the following clear opening
258Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9mm with lock plate of 3.15mm thickness reinforced with 35x35x5mm angle section fitted with sliding bolts and handles for both sides,deep M.S. channel section of depth and thickness not less than 65mm and 3.15mm respectively with holdfast arrangements, M.S.Bracket plate300x300x3.15mm minimum size and shape with square bar,suspension shaft of minimum 32mm diameter,hood cover of M.S.sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)
259Providing, supplying and installing Exterior ventilated facades in minimum 30 mm thk terracota facade panels of approved colour , shade & size bearing maximum weight of approximately 55 Kg/sqm, with fireglazed exposed surface, with water absorption of 1.5% to 3% , antistaining treatment and all fixtures as per approved detailed shop drawing using 3 mm thick aluminium single & double wall brackets with center to center spacing not exceeding 0.90m or as approved, with HILTI / FISCHER make hexagonal anchor bolts of size 10 x 80mm, tightened by mechanical means, with vertical frame in form of aluminium T profile in grade 6063-T6, of size 100 x 60 mm, with flange thickness of 1.80mm and web thickness of 2.00mm , with 0.50mm deep serrations on the flange with fastening clips in SS410 plate 1.20mm thick , round & bent to facilitate mounting of terracota panels, to maintain a horizontal louvered groove of 7/8 mm width , with silicon sealant beading on the side of rear surface of terracota panels including all necessary materials, hardware, fixing, Scaffolding , inspecting, cleaning etc. complete. Rate to include supply & fixing of powder coated G.I. sheets/ aluminium angles for metal profiles at corners, jambs, soffits etc. Material supporting arrangements shown in the drawing are indicative and contractor shall make their own shop drawings and suggest method of fixing with type of anchors they propose to use where they are to be fixed. Work to include required double legged independent scaffolding for entire height or as required to approval of the PM.
260Supplying and fixing of 6mm thick Exterior Compact Laminate or High Pressure Laminate of approved colour by approving authority with UV resistant Decorative colour paper on both side typically made out of multiple layers of craft papers and then impregnated with thermosetting phenolic resins, on top of it melamine treated barrier paper and decorative paper and wear layer on both the sides saturated with melamine resins and then covered with UV resistant acrylic resin layer which makes it extremely durable and weather resistant compressed together on extremely high pressure and hardened with electron beam curing to get the total desired thickness of 6mm matching European standard specification as per EN 438 -part 6, protected with 60 Micron protective peel-off film on both side which in no case leave any adhesive mark over the panel surface after it is peeled off. Fixing of the same to be done on a supporting frame of 50 mm X 5 mm X 3 mm powder coated aluminium box section to be spaced horizontally and vertically in 600mm X 600mm grid and fixed to building structure as per design through 50mmX50mmX mm 5 mm MS angle bracket prefixed to masonry slab or columns with Hilti make anchor fastener along with all related hardware and fixtures. The panel should then be fixed on the Aluminium section with the help of pure polyester exterior grade colour coating rivets as per architectural drawings or as directed by Engineer-in-charge. Each panel should be riveted on substructure maintaining a gap of 6mm on all the sides between each Panel for Air circulation and expansion and contraction as per installation specifications provided by the manufacturer. The cost shall include all expenses related to storage, material handling, lifting, freight, labour, scaffolding etc as directed by Engineer- in-charge. (Prior permission of S.E. is necessary before inclusion of this item in estimate)- Basement to Ground floor
2611st Floor
2622nd Floor
2633rd Floor
2644th Floor
2655th Floor
266Terrace Floor
267Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete.- Basement to Ground floor
2681st Floor
2692nd Floor
2703rd Floor
2714th Floor
2725th Floor
273Terrace Floor
274Providing structural steel work in single stanchions composed of R.S.J. Channel etc. with caps, bases, mild steel plated, angle brackets, cleats, gusset plates, anchor bolts etc. as per detailed designs and drawings or as directed including cutting, fabrication, hoisting, erecting fixing in position, making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it two. coats of oil painting approved quality and shade etc. complete.- Basement to Ground floor
2751st Floor
2762nd Floor
2773rd Floor
2784th Floor
2795th Floor
280Terrace Floor
281Providing & fixing Cold formed sections for roof purlins, girts eave struts & supporting arrangement and other miscellaneous structural parts in 345Mpa Yield strength , 275GSM galvanized . All purlins with pre punched holes of dia. 14 mm-16 mm-20 mm as per specified centre to centre spacing. Rod/ ANGLE bracing shall confirm to the Physical specifications IS 2062.
282Crane (a) 80 MT
283Cloes Hydra 830- 30 MT
284Providing and applying epoxy paint primer with middle coat and top coat to superstructure including scaffolding etc complete.
285Design, fabricate, package, deliver (to Job site) and install of semiunitized structural glazing system custom designed to withstand the design wind pressure with aluminium cleats, sleeves and splice plates , gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness,pressure equalisation & drainage and protection against fire hazard with all approved standard accessories and hardware’s of approved make. The glass panels will be mechanically supported to the aluminium main frame with pressure plate & cover cap on outer surface and fixed onto mullions and transoms including functional design of the aluminum sections for fixing glazing panels of various thicknesses. All aluminium extruded profiles shall be confirming to alloy 6063 T6. All Aluminium profiles shall be with pure ployster powder of thickness 75-80 microns and shade shall be as per architect's approval. The curtain wall shall be sealed to the host structure and not adjoining materials with approved water proofing membrane and insulation to prevent sound transmission. The System and glass shall be designed to withstand 1.5 times the design wind pressure at all levels, elevation & heights. The anchoring / bracing of the curtain wall system to the RCC slab / beams / columns shall be done with non-corrosive galvanized brackets of approved design (80-90 micron thickness) and including providing teflon shims of various thickness to adjust the beam level / line variations fixed with SS dash fasteners Hilti , Fisher or equivalent of min. 12mm dia. and depth of 50-80mm in the concrete and to withstand the dead load of the curtain walls as well as stresses due to wind pressure etc. Vendor should provide Mockup & prototype for approval.Expansion joint gap for mullion shall be minimum 15 to 20mm filled with expansion joint sealant from Dow Corning of DC 790 . All screws, washers used shall be only stainless steel of 304 grade and Through Bolts , Nuts & anchors used shall be only stainless steel of 316 grade.The contractor must design the system as per the prevalent site conditions and building elevation profiles. No extra claims shall be entertained at any stage for aluminium profile wall thickness and size dimensions. Material supporting arrangements shown in the drawing are indicative and contractor shall make their own shop drawings and suggest method of fixing with type of anchors they propose to use where they are to be fixed. including providing and supplying at site additional frame with all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineerin- Charge. Rate should be inclusive of required structural steel work painted with synthetic enamel paint ( two coats) with primer and required double legged independent scaffolding for entire height or at all levels , all height as required to approval of the PM.with Double Glass Unit of approved make & approved colour with 6 mm thick toughened clear glass inner side + 12 mm air gap (filled with dry air or argon gas) + 6 mm thick reflective toughened glass on External Side.
286Design of overall Tensile structure for canopy including membrane (fabric) & Steel. Supply of fabricated steel as per design, Erection, Painting of Steel structure & Installation & tensioning of Membrane (Fabric). Wind load of 44 m/s. 1.38 Kn/Sqm. Designing, Supply, Fabrication & Erection of Structural steel works with necessary Gusset Plates, Stiffener plates, Brackets, Bolts, Cleats etc., including painting. Structural frame shall be of Factory fabricated from structural steel using standard make IS 1239 pipes. YST240 the steel design shall be as per IS code 800. All segments of the assembly will be welded properly By mig weld & all sharp edges and corners are grinded. The steel shall be enamel painted with two coats at site (with brush) over zinc chromate primer for good finish. APPROVED MAKE:JINDAL/ APPOLLO/ SURYA/ NEUZONE, Designing, Supply Fabrication & Installation of PVDF fabric to be used is Serge Ferrari, France Flexilight 902S2(950 gsm) of tensile strength 420/400 daN/5cm and 832S2(850 gsm) of tensile strength 420/420daN/5cm. Steel cables, endplates, Tensioning hardware and all accessories. The fabric used for the tensile structure to be analyzed for its strength requirement and behaviour in tensile engineering software Ixcube and to be chosen after deriving through analysis. Fabric pattering is done on Ixcube software considering fabric prestress, structure form, welding joints and fabric elongation properties. All fabric patterns are plotted on fabric rolls by plotter and welded on high frequency welding machine in dust proof conditions. Fabric warranty period will be - 10 years. Colour of fabric are white and Grey Approved Make: Serge Ferrari, France Flexilight 902S2(white color) & 832S2(grey colour) both sides PVDF coated PVC fabric.All Structural wire rope shall be of 10 mm dia steel core galvanized 6/19, conforming to IS Steel Cable Manual requirement. End plate should be hot dip galvanized. All Cables and end fitting shall be delivered clean & dry. Swaged end fittings, Tensioning hardware (Viz. fork terminal, turn Etc) are galvanized & painted.Approved Makes: USHA MARTIN/DP WIRES complete as per drawing for finished item of work and as directed by the Engineer-in-Charge.
287Providing & fixing Asphalt shingles in approved colour and pattern for roof and ridge over 10mm thk bison board/OSB Board with APP waterproofing membrane including all fixing arrangements such as screwing etc complete and ensuring water tightening.
288Providing and fixing frameless Single / Double leaf glass doors with 12mm thickness toughened crystal edge polished glass door with approved etching design of approved make & shade in curtain wall glazing system with door shutter fittings including the cost of top & bottom Pivot patch fitting, PVC door buffer panel connector pivot, over panel/side panel connector with pivot, bottom lock, stainless steel hardware fittings of 316 grade for operating door i.e. door handle 450mm Long (as per approved finish) on both sides with SS brush finish , floor spring of approved make and locking arrangement etc. complete including the cost of cutting the floor and making good the same, as per design and drawing all complete as required.
289Providing & fixing in position Frame less sensor operated glass double shutter sliding doors with 12 mm thick toughened crystal edge polished glass withapproved etching design manufactured to relevant I.S. codes from approved manufacturer including cost of activators, switches, track and mounting profile, Carrier, Door suspension device with adjustable fixture, Motor with decoder,Track rail, Return pulley, Basic module, control with integrated switched power supply unit and multi-way connectors for optional expansion modules, Door stop, safety sensors etc.Dorma Make or equivalent as required all complete at all heights as per approved drawing and as directed by the Engineer-in-Charge. All exposed edges of the glass shall be ground, polished and rounded. The door shall be provided with sensing devices to detect motion in front of the door( Both Inner and Outer face ), activate the control mechanism and thus open and close the door.
290Providing and fixing in position 13.52 mm laminated Toughened Glass Of Approved Make ,shade & Sizes (6mm reflective toughened Galss at top + 1.52mm PVB + 6mm toughened glass) for Entrance Porch Canopy. The cost includes the cost of providing and fixing of glass with 3M tape and all necessary fittings for fixing of glass Like Tensile wires for aluminium & MS support, glazing clips,rubber beadings using brass screws and joints will be sealed with weather silicone of dow corning 789 grade to make joints leak proof and also includes all incidental works complete as per detailed drawings and to the complete satisfaction of the architect scaffolding material etc complete.
291Providing & Fixing Double skin Standing seam roofing system proposed with outer top sheet with approved colour coated roofing sheet of 0.55 mm total coated thickness (TCT) of 350 MPA & inner bottom sheet of colour coated roofing sheet of 0.50 mm total coated thickness (TCT) of 550 MPA to be fixed for clean roofing system , provides a clean, seamless look with no exposed flange bracing or purlins from below, offering a smooth ceiling appearance. Rockwool insulation with 75 mm thickness and having 48 kg/m3 density to be fixed between top and bottom sheet with subpurlins or Z spacers of 1.5 mm thk to create space for insulation. Panel side laps shall be field-seamed in 360 degree by portable seaming machine to make it leak proof. The seaming process involves the male and female ribs snuggly anchored on to clip heads and clips are fixed to structural members by self-drilling screws. All the purlin should have prepunched capsule holes of dia. 12-20mm at a distance of 1.2m c/c with service brackets. The rate shall include the provision and installation of all service bracket hangers, securely supported from the vertical web (side) of the purlins. This includes sealing any holes or gaps in the bottom sheet, created for fixing the service brackets, using silicone sealant to ensure a neat and weather-tight finish.
292Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950- 1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center- to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (weight of profile 4.52 Kilogram/ One Sq.m)
293Providing and fixing 150C exterior type colored linear aluminium panel false ceiling system consisting of panel 150mm wide x 15.5 mm deep x 0.5 mm thick aluminium with bevel edge, panel length up to 5m. The Panels shall abut each other with a narrow V grove. Panels shall be clipped to a baked enamelled aluminium Panel carrier of 32mm wide x 39mmdeep x 0.95mm thick black with cutouts to hold the panels in a module of 150mm closed at a distance 1.0 m. Panel carrier shall be suspended by means of G.I. suspension Threaded rod 6mm diameter mechanically fixed by means of nut and bolt at a distance of 1.5 mtr c/c. Paint finish: Aluminium Panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, outer side with full primer and Luxacoat/PVDF finish and the other side (inner side) with a primer coating and skin coat on a Continuous Paint Line.The item shall include providing markings and cutouts for electrical fixtures, sprinklers, smoke detectors, diffusers etc. on the ceiling and also providing & fixing templates in the ceiling made of 12mm to 18 mm BWP (boiling water proof) Plywood as required. All material shall be of approved make. Measurements shall be considered wall/beam to wall/beam without any deductions without any deductions for lights, diffusers, columns etc. All works shall be complete as per the drawing, specification and direction of the Engineer.
294Providing fixing 12 mm thk Shera Panel approved external grade colored Board of approved sizes in stripes with required spacing fixed on vertical as well on horizontal sides for ceiling and cladding work with anodized aluminum Tubes in grade 6063 at required spacing with anchor bolt, fastners , clip, screws etc. as per drawing and details complete job. Rate should be inclusive of required anodized aluminum tube , profile , scaffolding material etc. Rate to include supply & fixing of powder coated G.I. sheets/ aluminum angles for metal profiles at corners, jambs, soffits etc. Material supporting arrangements shown in the drawing are indicative and contractor shall make their own shop drawings and suggest method of fixing with type of anchors they propose to use where they are to be fixed.
295Providing,aupplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc. overall weight of the ACP shall not be less than 7.5 Kilogram/Square Metre)- Basement to Ground floor
2961st Floor
2972nd Floor
2983rd Floor
2994th Floor
3005th Floor
301Terrace Floor
302Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work.)Structural steel work for framing works will be paid seperatly in relevent Item.
303Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete
304Providing & fixing of Chemical Anchors with HILTI-HIT-V Rod with HY200RV3 mortar & Epoxy of RE500 V4 embeded in concrete by making Drill holes of the required diameter and depth using a rotary hammer drill. Clean drilled holes thoroughly using compressed air and a steel brush to remove dust, debris, and moisture. Chemical injection to be done using HDE GUN. Rate should be inclusive of installation, curing, and testing as per manufacturer’s instructions & Specifications. - 16 mm chemical anchor fastner embedded upto 150 mm inside concrete
305Providing & fixing of Chemical Anchors with HILTI-HIT-V Rod with HY200RV3 mortar & Epoxy of RE500 V4 embeded in concrete by making Drill holes of the required diameter and depth using a rotary hammer drill. Clean drilled holes thoroughly using compressed air and a steel brush to remove dust, debris, and moisture. Chemical injection to be done using HDE GUN. Rate should be inclusive of installation, curing, and testing as per manufacturer’s instructions & Specifications.- 20 mm chemical anchor fastner embedded upto 150 mm inside concrete
306Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 600 mm diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
307Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 750 mm diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
308Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 900 mm diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
309Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 1000 mm diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
310Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C. Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape ,welding the joints and driving with the help of required machineries including all materials labours and lifts etc. complete as directed by the Engineer in charge. Upto 3.00 meter deep liner
311Providing placing and Driving in position 6 millimeter mild steel liner for R.C.C.Piles upto required depth with 12mm thick mild steel cutting edge of 0.50m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape,welding the joints and driving with the help of required machineries including all materials labours and lifts etc.complete as directed by the Engineer incharge. Spec:(Asdirected by Engineer in Charge From 3.00 to 9.50 meter deep liner
312Empty boring for 525 to 600 mm dia. bored R.C.C. cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge)
313Chipping and dressing of the R.C.C. piles upto 0.60 meter including cleaning reinforcement and removal of dismantled materials upto a distance of 50 meter beyond the building area etc. for providing pile caps. Spec :(As directed by Engineer in Charge.)
314Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 550 mm and upto and inclusive of 750 mm dia. including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete
315Carrying out low strain pile integrity test on 600mm diameter pile including all arrangements for test, quipments/ accessories, materials, labour, submission of test report etcbut excluding the cost of installation of job pile (installation of pile shall be paid seperately as per releventitems)all complete as per specification and as directed by the engineer-in-charge
316Conducting routine vertical load test for 1.5 times safe load carrying capacity by means of High Strain Dynamic Load Test including provision and erection of crane- hammer-drop mechanism, acceleration and displacement velocity transducers to record both force and velocity including excavation, dewatering, preparation of pile head including building up of pile, additional reinforcement if any etc. all complete as per approved method (ASTM D4945-89), submission of test report, specifications and instructions of the Engineer for piles of following diameter :
317Providing and laying weep holes of 100 mm diameter PVC pipes as per drawing for abutment returns, return walls etc. Complete
318Providing, detailing, and fabricating as per specifications, transporting to site and erecting MS Openable / Sliding / Ornamental Entrance Gates including track and wheel, locking arrangement, fixing bolts, nuts, washers, cleats, stiffeners, gussets decorative balusters, arrow heads etc. and all necessary operations like straightening, bending, cutting, drilling, grinding, machining if specified, welding etc. complete weighing 60 to 65 kg/Sqm, including cleaning, Grinding and removing the welding burr and preparing surface and applying one coat of red oxide zinc chromate primer and one coat of Synthetic Enamel paint after fabrication and second coat of Synthetic Enamel paint after erection, with approved colour, shade and brand etc. including touching up with primer etc. complete as directed by Engineer In Charge.
319Providing and fixing bituminous pad 25mm thick for expansion joints in retaining wall, compound wall etc. complete.
320Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performancefor IRC 35:2015).
321Fabrication, Supply & Installation of MS Portable Cabin on site as per the design drawing provided by the engineer of minimum height 11’ and made of following material Top Frame of 50mm X 50mm Specially Formed M.S Square Pipe, bottom frame of 125 mm X 75mm Specially formed M.S. I Beam , 5mm Thick Horizontal Cross Member :- 100mm X 50mm Specially formed M.S. I Beam, 5mm Thick Vertical Cross Member :- 50mm X 50mm Specially Formed M.S Square Pipe Bottom Frame should be painted with Black Japan kind of material. Using 20mm X 40mm Specially Formed M.S Square Pipe as a stiffener for top, for side wall stiffener having 20 mm X 40mm Specially Formed M.S Square Pipe, and side post having 65mm X 65mm Specially Formed M.S Square Pipe. Outside panelling should be done in Specially Corrugated Sheet in Ms. – 1 mm thick (18 guage). For internal wall panelling 8 mm PRELAMINATED BOARD SHEET. SHADE- HIGHLAND PINE with Bidding Patti and L-Patti in Black Coated Aluminium material should be used. (Internal partitions, toilet/bathrooms toilet fittings and accessories to be paid separately) the rate is inclusive of transportation charges, electricity/diesel generator charges.) Detailed specification & drawing are available with the office of Dy.Ch.E.(HIC)
322Providing and fixing 45 cm wide G.I. rung ladder of ISMC 75 as a verticle runner fixed aprt 200 mm from wall with same section at 0.9 m center to center and steps of 32 x 32 x3 mm size G.I. pipe with anti-skid marks at a distance of 300 mm center to center for water tank including fixing it in RCC work with HILTI chemical fastner wherever required and painting the ladder with anti rust Pu coated paint & primer etc complete. - ( Length of ladder will be measured for payment purpose)
323Providing and fixing of PVC sleeves through RCC beams for passage of electrical conduits, plumbing pipes, AC drain pipes, or other services, made of heavy-duty rigid PVC, including cutting to required length, placing in correct position before concreting, and making good after removal of shuttering.- 50mm Dia.
32475mm Dia.
325100mm Dia.
326125mm Dia.
327150mm Dia.
328200mm Dia.
329Excavation pit size 1.00 x1.00 x 1.00m for planting large flowering/ shady trees (plant height 2 to 4 mtr.)/ palm varieties of height (plant height 2 to 4 mtr.) in earth, soil of all types, soft murum, including removing the excavated & unwanted material up to a required distance of 50 mtrs.
330Excavation for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed in earth, soil of all types, soft murum, including removing the excavated material up to a distance of 50 mtrs. for a depth of 30 cms.(As per P&G DSR 2022-23 Items of garden work,Sr No.3)
331Supplying on site garden soil well sieved 80 % to pass through I.S. sieve of 10 mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The color of the soil generally is red. The soil will be measured by measuring box. (Farma)Item includes Transporting, loading -unloading etc. (Lead charges per 70 km. considered. Excluding Royalty)
332Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The color of the manure generally is black. The manure will be measured by measuring box. (Farma)Item includes Transporting, loading -unloading etc ( Lead charges per 50 km. considered.)
333Spreading fresh garden soil / silt & manure in excavated pit size area of 1.00 x1.00 x 1.00m
334Spreading fresh garden soil / silt & manure in excavated area of depth 30cms.
335Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting required plant species as directed etc. complete for required pit size1.00 x 1.00 x 1.00m.
336Mixing garden soil/silt & manure thoroughly well, watering previous night. Planting required plant species; lawn grass as directed etc. complete for required depth 5 to 30 cms. for planting lawn/ shrub/ flower bed/ hedges/ edges/ canna bed/ ground cover
337Providing, laying and planting various Trees & Palms as listed below as per the mentioned size including adding fertilizers as per planting schedule, manure and Neem cake etc. including their maintainance upto 3 months during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer before plantation.
338Supplying & Planting shrubs, creepers, ground covers at 0.3 m C/c as listed below as per the mentioned size including adding fertilizers as per planting schedule etc. including their maintainance upto 3 months (after completion of the work) during which the contractor is suppose to maintain all these in all respects such as watering, pruning, spraying of pesticides, fungicides, insecticides, adding fertilisers, removing of weeds as per specification and direction of the Engineer-In-Charge and also replacing with similar plants in case of death of any plants. The plant will be selected and approved by the Engineer-In-Charge before plantation.
339Testing Charges - Coarse aggregate- Sieve Analysis
340Testing Charges - Coarse aggregate- Sieve Analysis-Specfic Gravity, Water Absorption, Crushing value &Impact Value
341Testing Charges - Coarse aggregate-Soundness
342Testing Charges - Coarse aggregate- F.I & E.I
343Testing Charges - Fine Aggregate (Sand)- Fineness modulus, Silt Content
344Testing Charges - Cement-Fineness, Initial Setting Time, Final Setting Time, Compressive Strength, soundness
345Testing Charges - R.C.C. M.40- Compressive Strength
346Testing Charges - R.C.C. M.40-Conc. Mix Design
347Testing Charges - R.C.C. M.40-Conc. - Permeability
348Testing Charges - R.C.C. M.30- Compressive Strength
349Testing Charges - R.C.C. M.30- Conc. Mix Design
350Testing Charges - R.C.C. M.30- Permeability
351Testing Charges - P.C.C. M.10 & M 15 for foundation- Compressive Strength
352Testing Charges - P.C.C. M.10 & M 15 for foundation- Permeability
353Testing Charges - HCRM / CRS (Corrosion Resistant Steel) bar reinforcement- Tensile strength, Elongation,wt per meter,Bend and rebend test -upto 16mm
354Testing Charges - HCRM / CRS (Corrosion Resistant Steel) bar reinforcement- Tensile strength, Elongation,wt per meter,Bend and rebend test -upto 20 mm
355Testing Charges - Ceramic Tiles/Vitrified tiles- Water absorp.
356Testing Charges - Natural stone-Water absorp.
357Testing Charges - Wood- Moisture content /Density
358Testing Charges - P.V.C. Pipes- Weight per running metre,Dia. & wall Thickness
359Testing Charges - Flush Door- Knife Test, Adhision test, End Emision test
360Providing and fixing white european type wall-hung, Size 360mm x 360mm x 575mm with flush valve having flow rate up to 6.0 Litr/Minute of Jaquar/Cera/Hindware /Perryware or equivalent make including PVC soil pipe,vent pipe upto outside face of wall, 100mm dia PVC plug bend inlet pipe all fittings, cutting & making good walls, floor setc as directed by Engineer in charge. (Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.)
361Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc.complete.Spec. No.:- As directed by Engineer Incharge
362Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessarysockets/ union nut etc. complete as directed by Engineer incharge.Spec. No.:- As directed by Engineer in Incharge
363Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195mm size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
364Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.
365Providing and fixing 450mm x 550mm size superior type Belgium mirror with16mm dia. nickel plated towel rod etc.complete.Spec. No.:- As directed by Engineer incharge.
366Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap,brackets for fixing the cistern, 32 mm dia.P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall.Spec. No.:- Bd.V.23 Page One Number 562
367Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete.Spec. No.:- As directed by Engineer in charge.
368Providing and fixing 100 mm dia.chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete.Spec. No.:- Bd.V. 12 Page Number 556
369Providingand fixing wall mixer withover head shower,showerarm,hand shower with wall bracket having flow rate upto12liters/minutesofJaquar/Cera/Hindware/Perrywareor equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer InCharge.(Makeshallconformtomanufacturer'sGreenproductandshallgot approved from the Engineer In Charge.)
370Providing and fixing stainless steel sink of size 600x510x200mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.
371Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore
372Providing and fixing JAQUAR MAKE, Model No. 1551 Toilet Paper Holder Recessed type (S.Steel) including cutting and making goodthe wall wherever required etc complete
373Providing and fixing ISI marked make CP brass liquid soap dispensers with CP brass bracket capacity 250 ml.
374Providing & fixing fully automatic \\"NO TOUCH\\" stainless steel 304 wall mounted hand drier suitable to operate on 240 volts, single phase 50 hz, A.C. power supply, with 1150W rated power & carbon brush motor
375Providing & fixing 150 mm SS 304 ACO Kitchen drain chanel including SS 304 grating on top.
376Supplying and erecting storage type water heater 15 litres capacity having standing loss < 0.381 kWh/24hour/45°C ,high impact resistance engineeringplastic body with anti corrosive high grade steel inner tank heating element having hard water& corrosion protection, with minimum 3 safety protections (i.e. thermostat &thermal cutout,multi function valve) completewith 3 core PVC flexible wire leads complete & total pressure 8 bar withstanding capacity duly tested and marking sr. no. and date of erection complete as perspecification no. AP-WH/STWH
377Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Spec. no.:- BD.V 5 page 551 and as directed by Engineer in charge
378Providing and fixing on walls/ ceiling/ floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Spec. no.:- BD.V 5 page 551 and as directed by Engineer in charge
379Providing and fixing on walls/ ceiling/floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Spec. no.:- BD.V 5 page 551 and as directed by Engineer in charge
380Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Spec. no.:- BD.V 5 page 551 and as directed by Engineer in charge
381Providing and fixing on walls/ ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.Spec. no.:- BD.V 5 page 551 and as directed by Engineer in charge
382Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete.Spec. no.:- BD.V 5 page 551 and as directed by Engineer in charge
383Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating ,bend,connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc.complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use)Spec. No.:- As directed by Engineer incharge.
384Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) Multi nahani trap
385Providing and fixing ASTM UPVC pipe (SCH 40), confirming to ASTM 1785 and bends confirming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. (sch-40)Pasting radium Colour band near Valve, Colour text, flow direction arrow on pipe line at every 5 Mtr. Colour codes to be followed as per direction of consultant. including openings in wall, corecuting in rcc structure & refurnish the same. Clamp/MS support, including excavation & Backfilling all type of strata with all depth (if required) (Make – as per approved make ) - 65 mm dia.
386Providing and fixing ASTM UPVC pipe (SCH 40), confirming to ASTM 1785 and bends confirming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. (sch-40)Pasting radium Colour band near Valve, Colour text, flow direction arrow on pipe line at every 5 Mtr. Colour codes to be followed as per direction of consultant. including openings in wall, corecuting in rcc structure & refurnish the same. Clamp/MS support, including excavation & Backfilling all type of strata with all depth (if required) (Make – as per approved make ) - 80 mm dia.
387Providing, fixing, jointing and testing uPVC sch 80 underground Pipes on with necessary fittings including , laying, testing, compacting complete as described in specification with M.S. Fabricated double angle bracket laying, complete as described in specification i the following U-PVC pressure threaded Pipes as per ASTM D 1785 Schedule80 and threaded conforming to IS:554. Cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. The pipes & fittings shall be tested to a pressure of 15 Kg/Sq.cm. Fixing at wall/ ceiling level supported by clamps, fastener, hangers etc. as per specification. Cutting hole in wall / floor slab and making good the same with cement concrete 1:2:4 complete as required. GI heavy class pipe sleeve of larger diameter shall be provided wherever the pipes crossing the walls/floor slab and sealing the sleeves as per consultants requirement. Threading, jointing & making proper connection. Pasting radium Colour band near Valve, Colour text, flow direction arrow on pipe line at every 5 Mtr. Colour codes to be followed as per direction of consultan(Make – as per approved make ) including excavation of trench in all types of strata with all depths and refilling, leveling of trench, shifting of extra earth or debris to dump yard complete as required., core cutting in rcc if required- 32mm Dia
38840mm Dia
38950mm Dia
39065mm Dia
39180mm Dia
392100mm Dia
393150mm Dia
394Providing and fixing approved cpvc ball valves full bore, with all necessary fittings & accessories i.e, unions, connectors, adapters, PTFE tape etc., All valves shall be PN10 pressure rated.complete as directed & specified. (Make: As per approved make)- 32mm
395Providing and fixing approved cpvc ball valves full bore, with all necessary fittings & accessories i.e, unions, connectors, adapters, PTFE tape etc., All valves shall be PN10 pressure rated.complete as directed & specified. (Make: As per approved make)- 40mm
396Providing and fixing on walls /ceiling/ floor 40 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
397Providing and fixing on walls/ ceiling/ floor 50 mm dia. uPVC pipe with necessary fittings, remaking good the demolished portion etc. complete.
398Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete
399Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete.
400Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592(1992) including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment)Spec. No.:- As directed by Engineer incharge.
401Providing , laying and fixing ,jointing Eco- drain 160 mm SN 4 Nu- Drain Upvc pipes orof equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees , coupler, etc, jointing with rubber lubricant includingnecessary excavation, trench refilling with selective excavated material etc. complete.
402Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line,level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench completeSpec. No.:-Bd.V.41, Page One Number 573
403Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line,level and slope including necessary collars, excavation, laying, fixing with collars incement mortar 1:1 and refilling the trench completeSpec. No.:-Bd.V.41, Page One Number 573
404Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete1:4:8 outside the building including cast iron grating in the sink, connecting glazedstoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trapSpec. No.:- Bd.V.38, Page One Number 572
405Providing and constructing Brick Masonry Inspection Chamber 60cm x45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram with frame etc complete.Spec. No.:- Bd.V.43, Page One Number 574
406Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes,Brick Masonry,plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram with frame etc complete.
407Providing and fixing in position FRP manhole cover and frame of required shape and approved quality (Inspection Shall be done as per guidelines of EN -124 : 1994) (For UGWT) Rectangular shape 600x450 mm internal dimensions
408Providing and constructing Ductile Iron circular manhole 45 cm dia. At top 90 cm at bottom up to 1.80 meter to 2.70 meter depth including excavation, laying 1:4:8 cement concrete bedding 15 cm thick burnt brick mansonry with 1:1 cement mortar plaster 25 mm thick inside and outside 20 mm (1:3) ductile iron heavy type cover with ring 125 Kilogramin weight. High strength. More life and Durability, Good Antiskid Grip,Suitable to heavy theatric loading, Light weight casting after cost benefits for Transportation Refilling etc. as per requirement. with prior approval of concerned Superitending Engineer.(For sewer)
409Providing and fixing Ductile iron Man Hole Covers/ Strom Water Grating and Grating with frame of Various sizes, weight and types and load bearing capacity as per EN-124, equivalent NECO with prior approvalof concerned Superitending Engineer.
410Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
411Supplying and erecting 65 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
412Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
413Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
414Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no.FF-VL/NRV
415Supplying & fixing 600 mm (24\\") to 750 mm (2'-6\\") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange (plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) a) 65 mm(2 1/2\\")dia pipe 5mm thick with 150X 150(6\\" X 6\\") plate, Both ends Flanged of
416Supplying & fixing 600 mm (24\\") to 750 mm (2'-6\\") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange(plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) b) 75 mm(3\\")dia pipe 5 mm thick with 200 X 200 (8\\" X 8\\") plate, Both ends Flanged of
417Supplying & fixing 600 mm (24\\") to 750 mm (2'-6\\") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange(plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) c) 100 mm (4\\")dia pipe 5mm thick with 250 X 250 (10\\" X 10\\") plate, Both ends Flanged
418Supplying & fixing 600 mm (24\\") to 750 mm (2'-6\\") long screwed G.I. C class pipe with 3 mm thick M.S. bar flange(plate) welded on it: Flanges should be of Table E of approved make. (Puddle Flange) d) 150 mm(6\\")dia pipe 7 mm thick with 300 X 300 (12\\" X 12\\") plate, Both ends Flanged
419Providing and fixing 80mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making lockingarrangement and lock.
420Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 150 litres per hour and storage capacity 150 litres with partially stainless steel body as per specification no. APWCR/WC
421Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
422Supplying, erecting, testing and commissioning of float sensor switch for water level controller working on 250 V & rated current 8A, with 2 m wire & high quality of wire & plastic body.
423Supplying & erecting pressure booster pump, single phase, 50 Hz, A.C.supply of 1.125 kW/1.5 HP, with discharge of 480 to 31 lpm for 10 to 50 m head& 25 mm suction/ 25 mm delivery pipe, for domestic Pressure boosting applications (with 24 ltr water tank) as per specification no. WP-PP
424Supplying, erecting, testing and commissioning of minimum three & above star rated centrifugal water pump (monoblock), 415 V, three phase, 50 Hz, A.C.supply of 11.25 kW/ 15 HP with discharge 1480/540 lpm for head of 24/74 m and 80 mm suction/65 mm delivery pipe on provided CC foundation as perspecification no. WP-CGP.(Domestic)
425Supplying, erecting, testing and commissioning of minimum three & above starrated submersible pump set suitable for erection on open well of 5.625 kW/7.5HP with 415 V, three phase, 50 Hz, A.C. supply having delivery head from 57 to22 m and discharge from 120 to 900 lpm & 75 mm suction/65 mm delivery dia.as per specification no. WP-OSP.(Flushing)
426Supplying, installing and commissioning automatic organic waste composting machine for 500 KG/day and including all required accessories
427Providing & fixing Potable SS Grease separator Trap of Aco make model FSS50,Part.No.402614 size 600 x 520 x 440 of 2 L/S flow.
428RWH-Shallow Percolation Pit providing,constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia precast RCC rings,300mm thick side filling around outside of RCCrings(annularspace)with 40mm size boulders including filling of percolation pit up to 0.5m depth(from bottom up)with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate(natural sand/crushed sand VSI grade finely washed etc.)including netlon mesh between each gravel/fineaggregate(natural sand/crushed sand VSI grade finely washed etc.)media layer including covering with RCC slab,manhole frame & cover,PVC rungs etc.including arrangement for inlet&outlet pipe,excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour,material,wastage,scaffolding,transportation,taxes,including all leads,lifts at all levels.All material should be of approved make.All works complete as per the drawing, technical specification and direction of the Engineer in charge.
429Supplying & erecting Dewatering Monoblock pump set 415V, 3 phase, 50C/s, A.C. supply of 2.25KW/ 3 H.P., of 12 to 26 m head with 560 to 70 LPM discharge, 10.5mm Solid Handling Capacity, non clogging minimised abrasive wear, large impeller clearance & maintenance free pump set with water proof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation. specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP (pump room sump ) (1w+1sb)
430Supplying, erecting, testing and commissioning of dewatering monoblock pump set 415 V, three phase, 50 Hz, A.C. supply of 3.73kW/ 5 HP of 9 to 18 m head with 1125 to 500 lpm discharge, 15.5mm solid handling capacity, nonclogging minimised abrasive wear, large impeller clearance & maintenance free pump set with waterproof cable duly sealed with epoxy material built in protection to prevent the motor from burn out due to abnormal operation, specially designed high efficiency motor with F class insulation & the pump mechanically sealed in the oil chamber,. etc. complete as per specification no. DWP- SMP.(basement sump)
431Supplying, erecting, testing and commissioning of dewatering monoblock pumpset 415 V, three phase, 50 Hz, A.C. supply of 5.5kW/ 7.5 HP, of 21 to 36 mhead with 910 to 190 lpm discharge, 14.5 mm Solid handling capacity, nonclogging minimised abrasive wear, large impeller clearance & maintenance freepump set with waterproof cable duly sealed with epoxy material built in protectionto prevent the motor from burn out due to abnormal operation. specially designedhigh efficiency motor with F class insulation & the pump mechanically sealed inthe oil chamber,. etc. complete as per specification no. DWP- SMP.
432Supplying & Fixing Prefabricated Sewage Treatment plant of 100 kld with opearting 24 hours of operating,with preatrement which includes screening,oil & grease trap,equliasation tank,secondary treatment which inlides bilogical treatment ,tube settler & disinfecation and sludge disposal sytem,Tertiary treatment as water paased thrugh series of filters,Perforated screen in MS epoxy construction Oil & grease trap chamber in civi lEqualisation tank in civil Anoxic Tank - in pre fab civil MBBR reactors – in pre fab civil Tube Settler – in pre fab civil Clear water tank/filter feed tank – in pre fab civil Treated water tank – in civil Sludge holding tank – in civil Sludge holding tank – in civil Sewage transfer pumps – Self priming, non clog, centrifugal Air blower with motor, diffuser membrane & associated equipments Tube media for Tube settler Poly dosing system Chlorine dosing system Filter feed pump Pressure sand filter Activated Carbon filter Interconnecting pipe & fitting, valves Sludge pump Electrical panel & equipment, Ozonation & UV Note -1.Stp to treated water tank parameters should meet enviroment standards.2.STP Vendor need to take all statutaory approval regarding enviromental clerance.3.STP vendor need to quote for all electromechanical equipment plus civil cost of all tanks. Contractor have to submit shop drawing before to execution.
433Supply, installation, testing, commissioning of 150KLD capacity water treatment plant which includes considering 10 hrs of working , Regeneration frequncy once in a day, raw water pump (1w +1s) flow rate 15 cum/hr @head 35 m , including required valves, piping, gauges and including all required accessories automation details in which plant will strat on low level in treated water tank and will stop on high level in treated water tank. (process prarameter may change according to water test report) Design, Engineering, and preparation of civil WTP drawings and providing all equipment / Piping etc at site, erection testing and commisioning of equipments/ electricals/ piping for Water treatment plant inclusive of all types of taxes and duties. Cost shall be inclusive of all works chiseling, finishing, corecut and making making good the walls, floors, slab wherever required. Cost shall be inlusive of flanges, nutbolt, pressure gauges, pressure transmitter/pressure switch ball valve, butterfly valve, NRV, strainer, pump & control panel mounting skid etc including all accessories required Cost shall be inlusive of unloading, checking of material list as per challan while receiving material, storage with security , reconciliation of material is in contractors scope
434Supplying and installing in position main table of approved make, colour and size with top made up of 25 mm thick exterior grade prelaminated particle board with 2mm thick PVC edge banding on all sides and supported on Gable ends/sides made out of mild steel frame of 50mm X 25 mm having powder coating of 60 to 70 micron thickness. & Modesty panels in 18mm thick prelaminated particle board. Gable ends & modesty panel exposed edges shall be finished in 2 mm thick PVC edge banding & sealed edges shall be in 0.8 mm thick PVC edge banding. Wire routing/ wire management shall be provided on main table or side table as specified. Table shall have independent Mild steel powder coated CPU trolley, wire manager and MS powder coated key board tray of standard size. The keyboard tray shall accommodate mouse pad. The side table of approved size shall have top made up 25 mm thick exterior grade prelaminated particle board top with 2mm PVC edge banding & supported with storage cabinet below in 18mm thick prelaminated particle board, back sheet of 9 mm thick prelaminated particle board and skirting of 75 mm height. Cabinet shall have two equal size shutters in 18mm thick prelaminated particle board with 2mm thick PVC edge banding and fixed with S.S. brush finish brass hinges & shall be provided with full length aluminium G profile handles / 4'' S.S. 304 grade brush finish handles, premium lock, and one shelf in centre fixed on shelf button. The pedestal unit of size 350mm(L)X450mm(W)X550mm(H) shall have top made up of 25 mm thick prelaminated particle board & sides in 18 mm thick prelaminated particle board and 75 mm height skirting with 2mm thick PVC edge banding on exposed edges 0.8 mm thick PVC edge banding on sealed edges. The pedestal shall have three equal size drawers with front fascia having central locking system & full length aluminium G profile handles/ 4\\"SS 304 grade brush finish handles ,roller slide mechanism and casters for added mobility. All exposed edges shall have 2mm thick PVC edge banding and sealed edges shall have 0.8mm thick PVC edge banding. All material shall be of approved make. All works complete as per the drawing / Image, technical specification and direction of the Engineer. CABIN TABLE (T1)(TABLE SIZE: 1500mm(L) X 750mm(D) X 750mm(HT) , SIDE TABLE SIZE : 900mm(L) X 450(D) X 750(HT)
435Providing & installing in position table made of S.S. 304 framework and 10 mm thick plain glass on top fixed in it . All works complete as per the drawing/ Image, technical specification and direction of the Engineer. CORNER TABLE (S.S. FRAME WITH GLASS TOP) (T2)SIZE: 600MM(L) X 600mm(D) X450 mm(HT)
436Providing & installing in position wooden side table made of teak wood and having wooden legs and horizontal frame of size 50x50mm, 10 mm thick plain glass on top fixed in 10 mm groove made in horizontal frame. The table shall include necessary hardware fittings, fixtures etc. The table shall be finished with 3 coats of melamine polish of approved colour. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.- CORNER TABLE (WOODEN FRAME WITH GLASS TOP) (T3)TABLE SIZE: 600MM(L) X 600mm(D) X450 mm(HT)
437Providing & installing in position table made of S.S. 304 framework and 12 mm ply with 6mm thick solid acrylic surface top. Solid acrylic top shall be buffed to achieve the required finished. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. - CENTRE TABLE (SS FRAME WITH SOLID ACRYLIC SURFACE TOP) (T4)TABLE SIZE: 900MM(L) X 600mm(D) X450 mm(HT)
438Supplying and installing in position Circular Dining table of approved make, colour and size with top made up of 25 mm thick exterior grade prelaminated board and having superior edge profile with 2mm thick PVC edge banding of matching colour. The under structure of the table shall be made up of 8mm Hot Rolled stainless steel 304 grade plate with Levelers & a vertical support tube of stainless steel 304 grade 90mm diameter. The base shall be circular at the bottom and top. The top base shall have required holes for fixing table top to it. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. - DIINING TABLE (T5)TABLE SIZE: 1400MM(dia) X750 mm(HT)
439Providing, fabricating and fixing in position Panel based modular Linear workstations which Includes Partition, work surface, side table & MS powder coated CPU trolley. Work surface,modesty panel will be in 25mm thick exterior grade prelaminated Particle board with 2mm thk PVC imported edge banding tape for tops & 0.8mm thk PVC imported edge binding tape for verticals. The bottom surface of the table shall also be laminated. The worktops will be supported by MS powder legs and frame. The worktops shall be provided with PVC wire manager for cabling. Partition: Partition thickness will be 25mm. Frame Horizontals will be of 1mm thick CRCA sheets & the verticals will be of Aluminium Extrusions of 1.5mm thick. All the frames will be duly powder coated based which will be in line with the Top trims & end trims.Tiles: The fabric tile panels will be Constructed out of 4mm thick Medium Density Fiber Board (MDF) and covered with Fabric of choice. One of the tile panel will be Whiteboard marker tiles made out of 4mm MDF with 1mm glossy face laminate with a balancing laminate on the back. And one of the tile panels will be Magnetic tile Constructed out of 0.8mm Galvanized sheet and covered with fabric of choice. Drawer Pedestal: The Pedestal Unit of Dimensions 400W x 470D x 675mmH will be made of 18mm thick pre laminated particle board. All the exposed edges will be sealed with 2mm thick PVC Imported edge banding on sides and bottom. The top and drawer fascia will be sealed with 2mm thick PVC edge. The drawer unit will consist of 2 box drawer and 1 file drawer. The sides of Inside drawer box will be of prelam particle board. The drawer box will be fitted with roller Slide for free movement. The drawer unit is provided with central locking system, where in the three drawer will be locked with one key.PVC recessed handles will be provided. The drawer unit will be fitted on castors. Wire management: Internal Concealed raceways to be provided below work surface with switchboard arrangement for Power & Data along with PVC Wire manager with Grommet / scallops & Individual raceway arrangement for Data/ Power cable. CPU Trolley & Keyboard tray: CPU trolley will be made from 1mm Thick CRCA steel sheet. The trolley will be mounted on lockable castors. The keyboard tray will be MS powder coated & will be fixed on telescopic channels & have provision for mouse pad. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer. - STAFF AREA LINEAR WORK STATION (W1) TABLE SIZE : 1200 mm(L) X 600 mm(D) X 750 mm(HT)EACH PARTITION SIZE: 1200 mm(L) X 25 mm(D) X 350 mm(HT) STAFF
440Supplying and Installing in position of Single sided slotted angle metal rack made up of Slotted Angles: of size 40mm X 40mm X 2mm thickness and shelves of size 900mm X 600mm X 1.2 mm thick, Machine Multi-band Moulded to withstand load of 75-100 kg per shelf. The Grade of Steel shall be CRCA Sheet Steel of approved make. The painting shall be a 7 tank process with oven baking. Corner Plates of size 81mm X 81mm X 1.2mm shall be provided. Nut & Bolts shall be MS Chrome/ Galvanised with minimum 30 microns. The Inter connections/ Cross supports shall be in 40mm X 40mm X 2mm thick angles with lap joint. The products must be complying to IS: 513 & IS: 1079. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.- SINGLE SIDED SLOTTED ANGLE METAL RACK (MR1)SIZE:900mm(L)X 600mm(D) X 1830mm(HT)
441METAL STORAGE CABINET (MSU1) - METAL STORAGE CABINET (MSU1)(SIZE: 750mm(L)X 450mm(D) X 2100mm(HT) Full Height Steel Storage @ 750L x 450D x 2100HT Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Topin 2mm thick CRCA, 4Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing.(SIZE:750mm(L)X 450mm(D) X 2100mm(HT)
442Cabin Chairs High Back (C1) Cabin Chairs High Back Providing & Arrangemnt of high backchair-Tiltme chanism withmulti locking,High density cushionon seat composite leather with metallic silver finish baseandarms with p.U.Castorsgas lift For Height Adjustment.
443VISITOR CHAIRS MID BACK (C2) VISITOR CHAIRS MID BACK Providing & Arrangemnt of Mid Back, ECOCTS Mechanism ,Fixed Armrest,Gas lift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery
444STAFF CHAIRS MID BACK (C3) STAFF CHAIRS MID BACK Providing & Arrangemnt of Mid Back, Normal Syncro Mechanism, Fixed Armrest,Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery.
445AUDITORIUM CHAIRS (C4) - Supplying and placing in position Auditorium chairs.Auditorium Chairs-Tip up :- Chairs-Type: Fixed back ‘Tip Up’ chair with yoke type M. S. Frame with single stud floor mounting chair, with fully upholstered seat and back rest using specially mould P. U. Foam with cloth / rexin covering. Central Distance 20” with Spacer 21”. Backrest Height 24”. The Frame : 1 ‘U’ shape yoke type frame made of 65 mm (W) x 5 mm thk M. S. Flat die press bent in power-press, to required curvature, with vertical limbs of 370 to 380 mm height and distance between two vertical limbs to be suitable for chair sitting of 500 to 530 mm handle centre to handle centre. The yoke to be strengthened at curved bottom using 1.5 mm thick triangular shape M. S. Plate wielded to yoke bottom. 2 The yoke to be wielded with stud and floor mounting base plate, the stud made of 1.5 mm (14 SWG) thk 60 x 60 mm M. S. Square Tube with 5 mm thk, 220x115 mm M. S. Plate welded to stud. The stud to be strengthened at back side using triangular shape support made of 1.5mm thk M. S. Sheet. 2- Back rest support of 12 mm thick waterproof plywood of 450 mm (W) x approx 550 to 600 mm (H) hot pressed to required curvature and tailor shaped as per design, with specially moulded minimum 45 mm thk P. U. Foam of density approx. 42 to 45 Kg / Cu. Mtr., covered with cloth covering. The back side of Back-rest to be covered with same cloth, padded with7 mm thk foam inside.3) PVC Moulded Armrest with cup Holder.Miscellaneous: Star Nuts to be embedded in back-rest for bolt fixing of back-rest to frame. M. S. Studs 10 mm dia to seat brass bush with matching hole to studs brazed in frame for fixing seat to frame, with 2.5 mm to3mm thk M. S. ‘L’ angle plate of size 75 to 100 mm (L), 12 mm dia stopper stud. 18 to 20 SWG thick 25 mm x 40 to 50 mm Aluminium number plate with Nos. engraved.12 mm thick 20 to 250 mm (W) and 375 to 450 mm (L) tailor shaped to design and power-press, curved to Match the curvature of back-rest, welded to vertical limbs of yoke to provide tilt angle of 107 to 110 degrees (to horizontal plane) as required. 4 The entire framework shall be powder coated. The Seat and the Back – Rest 1 -19 mm MDF board support base to seat of approx size 450 x 450 mm tailored to required shape, treated with anti-termite coat, specially moulded minimum 62 mm thk . All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.
446CONVENTION HALL CHAIRS. (C5) -Supplying and Placing in position Chairs of approved make and colour moulded in polypropylene. The seat and back will be of one piece injection. The tubular understructure to be fabricated from dia 19.0 x 1 mm thick ss. 202 grade tube welded together with ss connecting rod dia 8.0 mm. The understructure to be provided with black PP injection moulded ferrules. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.
447DINING CHAIRS. (C6)- Supplying and Placing in position upholstered Chairs with arms of approved make, colour & size with cusioned seat & back made of natural and biodegradable material-Rubber wood of section size 25mm x 35mm. Providing water fall edge. Well cushioned back and seat made up of HR (high-resilience) foam (foam density 32 kg/m3). All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.
448GREEN ROOM CHAIRS. (C7)- Supplying and Placing in position upholstered Chairs with arms of approved make, colour & size with cusioned seat & back made of natural and biodegradable material-Rubber wood of section size 25mm x 35mm. Providing water fall edge. Well cushioned back and seat made up of HR (high-resilience) foam (foam density 32 kg/m3). All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.
449Supplying & placing in position sofa of approved design, colour and size having solid frame structure with inner frame made of kiln chemical treated approved high quality wood. The seat cusion shall be made of 7\\" multi layered foam of density 32D and HD with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The thread used shall be nylon bonded to provide lasting stitch strength. The backrest shall be made of 3 inch foam of 23D with polyester polyfill outer layer of 180 gsm to keep the upholstery wrinkle free & soft. The seating cushions shall have 2 inches of elastic webbing of 250 gsm with diagonal weave. The thread used shall be nylon bonded to provide lasting stitch strength. The outer finish shall be of superior quality leatherette (upto Rs. 1000 per metre) stitched with nylon bonded thread. The legs shall be of s.s 304 grade tubular section of dia 75mm and 2 mm thickness with rubber gasket. All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.(Seat Height - 410 mm). - 1 SEATER SOFA (S1)
4502 SEATER SOFA (S2)
4513 SEATER SOFA (S3)
452HELP DESK (B1) -Providing & fixing in position help desk in 19 mm thick Marine BWP (boiling water proof) plywood with Ledge on one side & front fascia, top finished with 6mm thk 100% acrylic UV grade solid surface of approved shade and remaining surfaces 1mm thk laminate externally & internally. Table shall be provided with fixed drawer units having 3 number of drawers in 19 mm thick plywood front fascia, 12 mm ply for sides and back, with 6 mm ply for base and shall be supported on telescopic side mounted channels. The drawer unit shall have central locking arrangement & SS 304 brush finish handles (100 mm).The side table shall be in19 mm thick Marine BWP (boiling water proof) plywood & finished with 1mm thick laminate externally and 1mm thick laminate internally, back sheet in 8mm plywood & cabinets with drawers and/or shutters & single shelf each in 19mm ply with second class Indian teak wood lipping on all sides & finished with 1mm thick laminate & fixed on SS finished shelf buttons All exposed edges shall be finished with second class teak wood lipping with 2 to 3 coats of melamine polish to match the shade of laminate with necessary labour. Provision shall be made for wire management to take care of basic wiring requirement for providing power data- voice switches on a modular switch plate.Table shall have independent wire manager of standard size, Stainless steel finished hardware. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
453TICKET COUNTER (B2)- Providing & fixing in position Ticket Counter with main table in 19 mm thick Marine BWP (boiling water proof) plywood with ledge & front fascia with, top & sides in 19mm thk ply & finished with 1mm thk laminate internally & externally. Table shall be provided with fixed drawer units each having 3 number of drawers in 19 mm thick plywood front fascia, 12 mm ply for sides and back, with 6 mm ply for base & finished with 1mm thick laminate externally and 1mm thick laminate internally and shall be supported on telescopic side mounted channels. The drawer unit shall have central locking arrangement & SS brush finish handles (100 mm). All exposed edges shall be finished with second class teak wood lipping with 2 to 3 coats of melamine polish to match the shade of laminate with necessary labour. Provision shall be made for wire management to take care of basic wiring requirement for providing power data- voice switches on a modular switch plate.Table shall have independent wire manager, Stainless steel finished hardware. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
454CALCIUM SILICATE FINISH PARTITION (B3)- Providing & fixing in position solid partition made of aluminum framework of size 65mm x 38 mm tubular frame ,18 gauge having grid spacing at 600mm x600mm center to center both ways & covered with 8 mm thick Marine BWP (boiling water proof) plywood on both sides of framework & finished with 12mm thick calcium silicate plasterboard. The framework shall be properly screwed to the walls, ceiling and floor and plywood shall be screwed to the framework. The space between the framework grid shall be filled with glass wool having density of 48 Kg/ Cum for sound insulation. Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. All material will be of approved make. Measurements shall be calculated from finished floor level to false ceiling level, the framework above false ceiling will not be calculated but the rate shall include the cost of framework above false ceiling upto slab/beam bottom wherever applicable. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number -H-IN-601,H-IN-602,H-IN-603, H-IN-201,202,203,204)Note: Measurement shall be paid from floor finish to false ceiling but framing to be done till RCC ceiling/beams bottom which is not payable extra.
455GLASS PARTITION (B4)- Providing & fixing full height glass partition upto 2400 mm height with 12 mm thick toughened glass having etching pattern/3M film as approved fixed on Twin pro Interlocking anodized solid aluminum Single glazing profile both sides as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion.The item also includes silicon filling in between glass & lipping . All material shall be of approved make.All works complete as per the drawing, specification and direction of the Engineer.
456SINGLE SHUTTER GLASS DOOR (B5) (Size - 900mm(L) x2400mm(HT) - Providing & fixing in position single shutter glass door using 12 mm thick toughened glass having etching pattern/3M film as approved & fixed using double action floor spring, SS brush finish solid top patch with pivot and provided with SS 304 grade matt finish handle, SS brush finish solid bottom patch lock .All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
457STORAGE CABINET WITH SHUTTERS 450 mm DEPTH (B6) - Providing & fixing in position Storage in 19 mm thick Marine BWP (boiling water proof) plywood & finished with 1mm thick laminate internally & externally. Back sheet in 8mm plywood & shutters in 12mm thick ply frame with 6mmply on both sides and fixed on SS. brush finished brass 'L' hinges . Shelves shall be in 19mm thick ply finished with laminate and fixed on SS shelf buttons. All exposed edges shall be finished with second class Indian teak wood lipping with 2 to 3 coats or more of melamine polish to match the shade of laminate & complete with necessary labour,hardware, cleaning, placing in position etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
458GREEN ROOM DRESSING LEDGE (B7)- Providing & fixing table with 78 mm thk and 450 mm width ledge in 12mm BWP (boiling water proof) ply with 25 x 75mm plywood frame and finished in 1 mm thick laminate and edges finished with 2nd class Indian teak wood lipping with 2 to 3 coats of melamine polish to match the colour/shade of the laminate. 50Mmx150mm cable manager band in ply finished with 1mm laminate shall be provided & provision shall be made for wire management to take care of basic wiring requirements for providing switches on a modular switch plate. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.)
459GREEN ROOM STORAGE CABINET (B8)- Providing & fixing in position Cabinet Storage in 19 mm thick Marine BWP (boiling water proof) plywood & finished with 1mm thick laminate externally and 1mm thick laminate inside. Back sheet in 8mm plywood & Shelves shall be in 19mm thick ply finished with laminate and fixed on SS shelf buttons. SS Hanger rod shall be provided. All exposed edges shall be finished with second class Indian teak wood lipping with 2 to 3 coats or more of melamine polish to match the shade of laminate & complete with necessary labour,hardware, cleaning, placing in position etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
460CURTAIN PELMET (B9)- Providing & fixing in position pelmet upto depth of upto 200mm in 12mm BWP plywood finished with 12.5 mm gypsum board externally and 1mm thick laminate internally. Pelmet shall be fixed with supports in 19mm thick BWP plywood from wall/ceiling. All exposed edges shall be finished with 1mm laminate/PVC edge banding. All works shall be compete with necessary labour, hardware, cleaning, placing in position etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
461ALUMINIUM METAL SKIRTING (B10)- Providing & fixing in position modular metal skirting in powder coated aluminium profiles fixed on wal/panelling/partition etc. of approved shade. All works comeplete with necessary labour,hardware, cleaning, placing in position etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
462MIRROR PANELLING (B11)- Providing & fixing in position mirror paneling in 12mm thick plywood on wall in 6mm thick mirror, having plain edge polish on all sides and fixed using silicon sealant with all necessary hardware , fittings , etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
463LAMINATE FINISH PANELLING (B12)- Providing & fixing in position wall paneling in 19 mm thick Marine BWP (boiling water proof) plywood finished with 1mm thk laminate. The paneling shall have 100mm depth horizontal & vertical framework at 600mm c/c in 19mm thick ply fixed on wall. Provision shall be made for indirect lighting necessary,if required, labour, hardware, cleaning, placing in position etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
464TOILET CUBICLES (B13)- Supply and installation of cubicles of width and depth as per specifications/ sitedrawings.Cubicle height will be 1980mm Titan Std Series Cubicles: Std Sizes (W x D xH): 900mm x 1550mm x 1980mm /2039mm (Height is including 150mm gap frombottom) Door Size-600mm when top rail of rectangular cross section is used and 2039mm when top rail of circular cross section is used ITEM DESCRIPTION Made from solidgrade Merino make compact high pressure laminate as per IS:2046 and EN-438manufactured under high specific pressure>5MPa and temperature>120°C, All doorswill be of single colour and made of 12mm thick Merino HPL compact panel. Allpilasters will be made of 12mm thick HPL compact panel. Size of panels to be as perdrawing.HARDWARE & ACCESSORIES are Top rail is made of stainless steel grade304. There are two options for the top rail. First one comes with a rectangular crosssection (Size to be 55mm x 42mm x 1.6mm T) and the other one comes with circular cross section (Diameter 32mm). Surface finish to be brush type A thin plastic film pasted for surface protection. Corner joinery section made from Stainless steel grade 304. Surface finish to be brush type. A thin plastic film pasted for surface protection . Size to be 35mm x 15mm x0.8 mm. etc complete.
465TABLE WITHOUT PEDESTAL (B14) (Size - 1200mm(L) x600mm(W)2400mm(HT)- Table: Supplying and installing in position table of approved make, colour and size, having main table with top made up from 19+6 mm thick BWP IS : 710 plywood finished in 1 mm thick laminate internally & externally, supported on 50x25mm powder coating of thickness 50 to 60 microns mild steel frame and 50x50mm powder coated mild steel legs and having Modesty panel in 19mm thick BWP IS : 710 plywood. Table will have independent wire manager. All 25 mm thick exposed edges of plywood shall be finished with 2mm thick & 19/12 mm thick exposed edges of plywood shall be finished in 0.8 mm thick PVC (Polyvinyl Chloride) edge banding machine pressed in matching colour. (Rehau Make / or Equivalent) for better impact resistance etc. complete. All material shall be of approved make. All works complete as per the drawing / Image, technical specification and direction of the Engineer .
466TRAP DOOR- Providing & fixing in position 28mm thick trap door, frame work in Aluminium framework of size 38mm x 65mm of thickness 18guage from slab bottom to false ceiling height .Door in12 mm thick Marine BWP (boiling water proof) plywood with 6mm plywood on both sides and finished with french polish internally and 4mm MDF with approved paint externally.Paint to be measured separetly in painting item. Door shall be fixed on heavy duty SS. brush finished brass hinges, with necessary hardware like concelled lock, ss chain etc. Measurements will be considered for door size only. The rate shall include cleaning, placing in position, etc. complete. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
467PLATFORM FOR CONVENTION HALL- Providing & fixing 200mm height platform with framework in 38 x 180mm second class Pine wood planks at approximately 600mm x 600mm centre to centre placed both ways fixed as shown in the drawing. Top and sides shall be in 19mm thick Marine BWP IS:710 plywood finished with 1mm thick texture laminate IS:2046. All external exposed surfaces shall be finished with 3 or more coats of Melamine polish and french polish on underside/ internal surfaces complete with necessary labour and hardware, wire management etc complete as per drawing. All material shall be of approved make. Measurements shall be calculated of Top plan of platform (length x depth). All works complete as per the drawing, specification and direction of the Engineer.
468PODIUM FOR SPEAKER(SIZE:750mm(L) X600mm(W) x1000mm(HT) - Providing, fabricating and placing in specified position Lectern/podium using 19mm approved make Boiling water proof marine ply(BWP, IS Code 710:2010), top length :- 700/750mm, depth :-500mm and Height:- 1085mm with one shelf of 200 mm including making provision for mic, VGA cable for the podium top & as directed by Engineer etc. complete. All 25 mm thick exposed edges of plywood shall be finished with 2mm thick & 19/12 mm thick exposed edges of plywood shall be finished in 0.8 mm thick PVC (Polyvinyl Chloride) edge banding machine pressed in matching colour(Rehau Make / or Equivalent) for better impact resistance etc. complete. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
469PLYWOOD PANELING FINISH WITH CALCIUM SILICATE BOARD- Providing & fixing in position panelling made of aluminum framework of size 65mm x 38 mm tubular frame ,18 gauge having grid spacing at 600mm x600mm center to center both ways & covered with 18 mm thick Marine BWP (boiling water proof) plywood on one sides of framework & finished with 10mm thick calcium silciate board with paint of approved shade. The framework shall be properly screwed to the walls, ceiling and floor and plywood shall be screwed to the framework. Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. Provision shall be made for wire management to take care of basic wiring requirement for providing power data- voice switches on a modular switch plate. All material will be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
470PLYWOOD WALL PANELING FINISH WITH PVC FLUTED PANEL - Providing & fixing in position panelling made of aluminum framework of size 65mm x 38 mm tubular frame ,18 gauge having grid spacing at 600mm x600mm center to center both ways & covered with 18 mm thick Marine BWP (boiling water proof) plywood on one sides of framework & finished with pvc flutted panel of approved shade. The framework shall be properly screwed to the walls, ceiling and floor and plywood shall be screwed to the framework. Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. Provision shall be made for wire management to take care of basic wiring requirement for providing power data- voice switches on a modular switch plate. All material will be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
471PLYWOOD CEILING FINISH WITH PVC FLUTED PANEL - Providing & fixing in position plywood ceiling made of aluminum framework of size 65mm x 38 mm tubular frame ,18 gauge having grid spacing at 600mm x600mm center to center both ways & covered with 18 mm thick Marine BWP (boiling water proof) plywood on one sides of framework & finished with pvc flutted panel of approved shade. The framework shall be properly screwed to the slab/ beam and plywood shall be screwed to the framework. Provision shall be made for necessary cutouts for services such as wire management etc. as per design including all necessary hardware & accessories, grooves, adhesives, cutting & making good the original surfaces on completion. Provision shall be made for wire management to take care of basic wiring requirement for providing light fixtures, sprinklers, smoke detectors etc. All material will be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
472PLYWOOD PANELING FINISH WITH POLYESTER FIBER BOARD- Providing & fixing in position wall paneling in 19 mm thick Marine BWP (boiling water proof) plywood finished with 12 mm thick accoustical polyster fiber board with groove pattern. Provision shall be made for fixing PVD inlay patti. All works shall be complete with necessary labour, hardware, cleaning, placing in position etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
473PLYWOOD PANELING FINISH WITH TINTED MIRROR- Providing & fixing in position mirror paneling in 12mm thick plywood on wall finished in 6mm thick tinted mirror, having plain edge polish on all sides and fixed using silicon sealant with all necessary hardware , fittings , etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
474PVD INLAY PATTI- Providing & fixing in position stainless steel PVD profile inlay as per design in 20mm width SS304 grade section of approved colour coating and profile. The inlay profiles shall be fixed onto the surface of panelling/ wall etc. using necessary adhesive in line with the finished panelling level as per design. All works complete with necessary labour, hardware, cleaning, placing in position etc. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
475ACOUSTICAL DOUBLE SHUTTER DOORS- Providing & Fixing in position Acoustical Doors along with 300 x 80 mm teak wood frame, doors made from 50mm Teakwood frame 600x600 ctoc filled with 1000 Gsm synthetic wool 50mm thick and 3mmT ec sound from both sides, 12mm waterproof ply & veneer from both sides, including 150mm heavyduty SS hinges (Geze/Dormaoreq.)4no each leaf,with Door-closer (Dorma/Geze or eq.)including cost of required Cut-Outs,decorative mouldings / finishing-items/ melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects. including all materials labour, finishing etc. complete.
476Supply & Installataion Pull handle back to back fixing each door make (Dorma,Geze,Hafle ) as directed by Engineer in charge etc completed
477Supply & Installataion autodrop seal each door make ( Dorma,Geze,Hafle ) as directed by Engineer in charge etc completed
478Supply & Installataion mortise Cylinder dead lock back, set,24mm foreend With Euro profile double cylinder keyed Diff.Door lock 1 each door make ( Dorma,Geze,Hafle ) as directed by Engineer in charge etc completed
479Supply & Installataion 10mm thk rod SS tower bolt 4 each door make (Dorma,Geze,Hafle ) as directed by Engineer in charge etc completed
480LOWER REACH PANELS AUDITORIUM WALL PANELING - Supply and Installation of Anutone Tufbloc Spots Smery, square edge, magnesia cement core, perforated panels of 6mm dia perforations at 18mm pitch-TOA 8% with backing of acoustic fleece,panels of size 1200x2400x10mm, volume density of base board 1000kgs/m3, weight of base board 10kg/m2 ,GreenPro certified,finished with Anutone Smery acoustical fleece, size 1000x25000x1.0mm and acrylic paint (Paint not by Anutone) installed by using Anutone Strut framework system.Framing and boarding by boarding skillset: Anutone Strut framework system includes Anutone Strut CC25, fully knurled, sectional thickness 0.55mm, length 3600mm, web 50mm, depth of 25mm and equal flanges 15mm is fastened to wall or framework behind horizontally at every 400mm centres. Apply with glue gun, Stick GS glue beadline of 9mm diameter on Strut CC25 that will receive the boarding, one board layout at a time to ensure the glue does not dry up before boarding. Anutone Tufbloc Spots, 1200x2400x10mm is installed on the Strut CC25 by first pressing board firmly to framing to ensure strong connect with StickGS including gentle tapping at the glue beadline paths and then with self drilling drill tip fasteners in a staggered manner. Long edges of panels should be perpendicular to length of Strut CC25. 4mm gap should be maintained between adjacent Tufbloc Spots boards on all sides and filled and finished with Anutone Seam Kit using boarding skillset. Apply one coat of white primer (not by Anutone) with roller brush evenly across the Tufbloc Spots surface by painting skillset to achieve uniform colour of base surface to receive Smery in next step. Anutone Smery fleece Installation by wallpaper skillset only. Cut Smery rolls with sharp knife to required size. Apply Anutone Stick SG thinly, evenly and fully with hairbrush on both Smery fleece rearside and Anutone Tufbloc Spots. Paste the Smery on Tufbloc Spots and smooth it with plastic rasper using wallpaper skillset. Ensure all trapped air is removed fully per board layout before proceeding to next board layout.Ensure butt joints between successive Smery roll drops are fine and level. Wherever Smery joints are aligned with Tufbloc Spots perforations ensure to blind the perforations by using Seam kit to achieve smooth surface below the joints. Smery is finished with approved colour water base acrylic paint by using roller brush with painting skillset. Paint a second finishing coat on the Smery when the first coat is dry.(Paint not by Anutone). Note:-All 3 different and distinct skillsets of boarding, wallpaper and painting to be used while installation of Tufbloc Spots Smery to achieve desired results. One skillset cannot do it all to achieve desired results. Note:-Wooden packings of appropriate thickness to be provided at rear of strut to bring finish inline with Anutone Slim Lite Sculpt Spots Nano finish.The system is backlined with the acoustical infill Anutone SynthPF 10x25 adhered on wall with dab spots of Anutone Stick S7.• Fire (Class) – 1 & P • Acoustics – NRC upto 0.3 • Climate (°C, RH) – 50, 90• Light reflectance (%) – Paint dependent• Green (VOC, RC %) – Low, 30.
481UPPER REACH PANELS AUDITORIUM WALL PANELING - Supply and installation of Anutone Slim Lite Sculpt Spots Nano, core-pigmented high-density rigid polyfibre panels with surface embossed, panels enhanced with wooden finish having 0.5mm perforations @ 4mm pitch, panels of size 1220x2440x9mm, volume density 150kg/m3, weight 1.35kg/m2 adhered on Anutone backer board, square edge magnesite bonded 2mm widepinewood fibre core tiles of size 600x1200x15mm, volume density 400kgs/m3, weight 6kg/m2 installed by using Anutone Strut framework system. Anutone Strut framework system includes Anutone Strut CC25 thickness 0.55mm, length 3600mm, knurled web 50mm, depth 25mm and equal flanges 15mm is fastened to wall horizontally at every 600mm centres. Anutone backer board is installed on the Strut CC25 with suitable fasteners at 600mm centres. Longer edges of the panel should be perpendicular to length of Strut CC25.Anutone Stick S7 is adhesive applied on Anutone backer board and at rear of Anutone Slim Lite Spots Nano panel. Prior to installation, ensure surface behind are flat, dry and free from dust or other contaminants and leveled. Anutone Slim Lite Sculpt Spots Nano panels are then adhered to backer board behind with Anutone Stick S7 adhesive. The system is backlined with Anutone SynthPF 10x25 held in position with dab spots of Anutone Stick S7. • Fire (Class) – A• Acoustics – NRC upto 0.9 (for system)• Thermal (W/mk)– 0.04• Climate (°C, RH) – 45, 90• Light (%) – Shade Dependant • Green (VoC, RC %) – Nil, 60.
482CALCIUM SILICATE BOARD FALSE CEILING - Providing and fixing 8mm thick calcuim silicate board suspended false ceiling false ceiling in horizontal / vertical surfaces, stepped, cove ( straight & curvature). The calcuim silicate board having density of 850 to 950kg/m3, shall be made from Siliceous & Calcareous material reinforced with fiber,made in Laminar process and then autoclaved to give stable crstalline structure. The framework shall consist of approved make Galvanised iron (GI) Perimeter Channel of 0.55 mm thickness, two unequal flanges of 20 mm and 30 mm and web of 27 mm fixed to surrounding walls / partition by using nylon sleeves and screws at 450 mm centres. Approved make Galvanised iron (GI) Intermediate Channel of 0.9 mm thickness having two equal flanges of 15 mm each and a web of 45 mm shall be suspended from the soffit at 1220 mm centre with G.I.Cleat and steel expansion fasteners. Galvanised iron (GI) Ceiling section of 0.55 mm thickness having web of 50.5 mm and flanges of 26 mm each with lips of 10.5 mm shall be fixed to the Intermediate channel with connecting clips across to the Intermediate channel at 457 mm centres.respectively. Calcuim silicate boards of 8 mm thickness having taper edge /Square edge shall be screw fixed across the ceiling sections with 25 mm long self drilling. All works shall be complete as per the drawing, specification and direction of the Engineer.
483CALCUIM SILICATE TILE GRID FALSE CEILING 600 MM X 600MM - Providing and fixing false ceiling with eco-friendly light-weight calcium silicate tiles of spintone surface texture aerolite make or equivalent of size 595mmx595mm having 15mm thick densified micro look edge and 100% humidity resistance incombustible as per BS46 part IV and thermal conductivity 0.043w/m0KC and NRC 0.50 placedintrue horizontal level suspended grid of size 600x600mm made from hot dipped G.I.steel sections ion silhouette profile,rotary stitched double webbed white with 6mm reveal profile(white/black), wherein, main Trunner of size 42mm x 14mm between main tee 600mm center-to center and secondary crossT of size 33x14x0.43mm thick of length 600 mm long spaced inter-locked at middle of the first crossed T in each panel to form grid of 1200 mm x 600 mm resting on periphery wall Profile wall section19mm(7+7)x 19mm x 0.40 thicknesses and laying false ceiling for services like diffusers grills including cutting, making opening for light fittings ,fixtures,smoke detectors etc.,wherever required. Main T runners suspended from ceiling with using G.I.soffit cleats of size 25 x 35x 1.6mm of required length fixed to the ceiling with 6mm dia and 50mm long dash fastener,4mm dia G.I.adjustable rods with powder-coated/good quality G.I.level adjustment clips of 35 x35 x0.8 mm spaced @1200,center-to-center along main Tall complete at all heights as per the specifications, drawings and as per direction of the Engineer.
484PLAIN METAL TILE 600 mm x 600 mm GRID FALSE CEILING - Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid on grid systems with 15mm wide T - section flanges color white having rotary stitching on the Main Runner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.
485PERFORATED GYPSUM PLASTER BOARD CEILING(16% perforation in 12mm squares @ 25mmc/c) - Providing & fixing in position, N-29 Perforated Plaster Board 595 x 595 With square , perforations 16% .12.5 thick on \\"T\\" Frame work as per specification, with Glass wool of 48 kg/cum/50 mm thick , two coats of paint including cost of required cut outs, decorative moulding/finishing items and scaffoldings, as per Architectural & Acoustical Design & Instructions and complete in all aspects. (Auditorium ceiling). All complete as per the drawing, specification and direction of the Engineer.
486ACOUSTICAL FALSE CEILING IN AUDITORIUM - Supply and Installation of Anutone Tufbloc Spots , square edge, magnesia cement core, perforated panels of 6mm dia perforations at 18mm pitch-TOA 8% with backing of acoustic fleece,panels of size 1200x2400x10mm, volume density of base board 1000kgs/m3, weight of base board 10kg/m2 ,GreenPro certified,finished with Anutone Spun Smery acoustical fleece, size 1000x25000x1.0mm and acrylic paint (Paint not by Anutone) installed by using Anutone Strut ceiling framework. Framing and boarding by boarding skillset:Anutone Strut ceiling framework system shall include Anutone Strut WC25, fully knurled, sectional thickness 0.50mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm, fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers.Then suspend Anutone Strut MC45, fully knurled, sectional thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at 1200mm centers with Anutone Strut SA25, fully knurled, Suspender angle with sectional thickness 0.45mm, unequal flanges of 25 & 10mm such that free end of Strut MC45 rests on Strut WC25 along perimeter of wall.Extra support to be added near jointing of two MC45 so that end cantilever should not be more than 150mm. Anutone Strut CC25, fully knurled, sectional thickness 0.55mm, length 3600mm, web 35mm, depth of 25mm and equal flanges 9.5mm is fastened to the Strut MC45 perpendicularly at 400mm centers. Apply with glue gun, Stick GS glue beadline of 9mm diameter on Strut CC25 that will receive the boarding, one board layout at a time to ensure the glue does not dry up before boarding. Anutone Tufbloc Spots, 1200x2400x10mm is installed on the Strut CC25 by first pressing board firmly to framing to ensure strong connect with StickGS including gentle tapping at the glue beadline paths and then with self drilling drill tip fasteners in a staggered manner. Long edges of panels should be perpendicular to length of Strut CC25. 4mm gap should be maintained between adjacent Tufbloc Spots boards on all sides and filled and finished with Anutone Seam Kit using boarding skillset.Apply one coat of white primer (not by Anutone) with roller brush evenly across the Tufbloc Spots surface by painting skillset to achieve uniform colour of base surface to receive Smery in next step.Anutone Spun Smery Installation by wallpaper skillset only:Cut Smery rolls with sharp knife to required size. Apply Anutone Stick SG thinly, evenly and fully with hairbrush on both Smery fleece rearside and Anutone Tufbloc Spots. Paste the Smery on Tufbloc Spots and smooth it with plastic rasper using wallpaper skillset. Ensure all trapped air is removed fully per board layout before proceeding to next board layout.Ensure butt joints between successive Smery roll drops are fine and level. Wherever Smery joints are aligned with Tufbloc Spots perforations ensure to blind the perforations by using Seam kit to achieve smooth surface below the joints. Smery is finished with approved colour water base acrylic paint by using roller brush with painting skillset.Paint a second finishing coat on the Smery when the first coat is dry.(Paint not by Anutone). Note:-All 3 different and distinct skillsets of boarding, wallpaper and painting to be used while installation of Tufbloc Spots Smery to achieve desired results. One skillset cannot do it all to achieve desired results.The system is backlined with the acoustical infill Anutone SynthPF 10x50. Technical parameters • Fire (Class) – 1 & P• Acoustics – NRC upto 0.8 • Climate (°C, RH) – 50, 90• Light reflectance (%) – Paint dependent• Green (VOC, RC %) – Low, 30
487STAINLESS STEEL DUST BIN (10 -11 Litres )- Providing and placing in position 16 gauge stainless steel pedal dust bin of grade 304 cylindrical with cover of capacity 10-11 litres. All material shall be of approved make. All complete as per the drawing, specification and direction of the Engineer.
488PLASTIC DUST BIN WITH FOOT OPERATED LID ( 7-8 Litres)- Providing and placing in position virgin polymer (HDPE) dustbin of 7/8 litres capacity in thickness 2.5mm (+/-0.2mm) with a circular top .Bin shall be printed as per the requirements of Bio Medical Waste Management Rules – 1998 (amended till date). All complete as per the drawing, specification and direction of the Engineer.
489PLASTIC DUST BIN WITHROUND SPRING PUSH FLAP LID /FOOT OPERATED (60 litres) - Providing and placing in position virgin polymer (HDPE) dustbin of thickness 2.5mm (+/-0.2mm) with a circular top of 60 litres capacity. It shall be fitted with foot operated lid and handles for lifting (refer IS 3730:1988). It shall be fitted with round spring push flap lid. Bin shall be printed as per the requirements of Bio Medical Waste Management Rules – 1998 (amended till date). All complete as per the drawing, specification and direction of the Engineer.
490PLASTIC DUST BIN WITHFOOT OPERATED LID (120 Litres ) - Providing and placing in position virgin polymer (HDPE) dustbin of thickness 2.5mm (+/-0.2mm) with a circular shaped of 120 litres capacity all be fitted with foot operated lid and handles for lifting (refer IS 3730:1988). Lid mechanism shall be of SS 4mm (min.) rods only. Bin shall be fitted with 2 nos. Of SS square (hollow) pipe of 20mm x 20mm at bottom for steady placement and printed as per the requirements of Bio Medical Waste Management Rules – 1998 (amended till date). All complete as per the drawing, specification and direction of the Engineer.
491NATURAL GREEN PLANTS WITH PLANTER- Providing and planting natural green alive plants like Chefflera, Xanadu,Agloenema, Rhaphis palm, Areca palm,Syngonium (height 900 to 1200 mm maximum) for indoors including PVC pot (size : around 300mm dia x 400mm height) and placing it in stainless steel 304 grade cylindrical planter, size (around 450mm dia x 600mm height) complete with soil, manure, watering and handing over to client etc. All material shall be of approved make. All complete as per the drawing, specification and direction of the Engineer.All the materials shall be of approved make. All works complete as per the drawing, specification, image and direction of the Engineer (basic rate 450/- to 800/-)
492FLOOR MATS- Providing and placing in position PVC (Poly Vinyl Chloride) green mat of approved make, approved colour made of special polymer tufts that scrape stubborn dirt with designer anti-curl edge guards, natural elastomer base,100% anti skid, hygienic & non-toxic etc. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (size - 1800 x 750mm)
493(size - 900 x 600mm)
494Supplying & fixing in position approved painting in digital printing on digital printing paper with synthetic frame & lamination. The details need to be as per the instructions of Engineer. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. PICTURE FRAME (SIZE : 900 X 600 MM)
495PICTURE FRAME (SIZE : 900 X 900 MM)
496PICTURE FRAME (SIZE : 1200 X 600 MM)
497ROLLER BLINDS- Providing and Fixing Rollar Blinds AMI Make or approved make & shade of 38mm round Aluminium channel with Blackout fabric & telting with chain (Ball) system with all necessary fixtures and fitting etc.complete.(Sample to be final by Engineer In-charge prior execution of work.)
498CURTAINS- Providing and fixing in position approved 300+ GSM black out fabric curtains ( basic rate 900 rupees per meter ) with Amercian pleated ( basic rate 700 rupees per meter ) fixed on off white powder coated Aluminium M-track manually hand operated channel hung on walls and ceilings and are & inclusive of hardware fittings & accesories like runners, end caps, hooks, brackets, hook fixng cloth patti stiching etc. complete. Mode of measurement - only opening size shall be measured - the rate shall include curtain fullness of 250%. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
499MIRROR SIZE – 600mm(L) x 900mm(HT) - Providing and fixing 6mm thick Mirror on 12mm thick boiling waterproof plywood with silicon sealent and plain polish on all edges.The details need to be as per the instructions of Engineer. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
500CARPET ROLL- Providing and fixing in position, heavy duty 100 % polypropylene Carpet with 3 mm underlay, 980 gsm, 4 mtr width, fire retardant, plain backing, needle punch technology, 100 % stain proof fibers as per Architectural & Acoustical design, instructions and complete in all aspects.
501NATURAL WOODEN FLOORING- Stage Floor-Providing & fixing in position Stage flooring using 37mm thick (4''w x 5' L ) BTC planks on 18 mm water proof ply screwed to Teak wood frame of 50 x 50 mm wooden sections at 600mm c to c on stage surface including melamine polish, as per Architectural & Acoustical Design & Instructions & Complete in all aspects. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the EngineerAll the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
502Providing and fixing signage made of 1.5mm thick Stainless Steel plate of grade 304 with CNC Laser cut letters. This shall be fixed on 8mm thick transparent/ colored Acrylic board. The SS plate shall be fixed on the Acrylic board with 12mm dia SS studs of grade 304 with brass buttons and screws. The panel will be fixed on the door/wall with 12mm SS. stud /SS mirror screw arrangement /3m Tape or suspended from the ceiling by means of SS chain of 8mm dia with anchor fasteners complete as required. As per drawing and as directed by engineer. - INTERNAL SIGNAGES (SS FINISH) SIZE - 450mm (L) X 200mm (HT)
503INTERNAL SIGNAGES (SS FINISH) SIZE - 400mm (L) X 75mm (HT)
504INTERNAL SIGNAGES (SS FINISH) SIZE - 300mm (L) X 150mm (HT)
505Providing and fixing in position signages made from 4 mm thick aluminium composite panel with computer cut lettering of specified height and width, self adhesive vinyl pasted on it to protect from peeling. The panel will be fixed on the door/wall with 12mm SS. stud /SS mirror screw arrangement /3m Tape or suspended from the ceiling by means of SS chain of 8mm dia with anchor fasteners complete as required. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. - INTERNAL SIGNAGES (ACP) SIZE - 300mm (L) X150mm (HT)
506INTERNAL SIGNAGES SIZE (ACP) SIZE - 300mm (L) X 300mm (HT)
507INTERNAL SIGNAGES (ACP)SIZE - 900mm (L) X1200mm (HT)
508Providing and fixing in position signages made from 4 mm thick aluminium composite panel with computer cut lettering of specified height and width, self adhesive vinyl pasted on it to protect from peeling.The panel will be fixed on the door/wall with 12mm SS. stud /SS mirror screw arrangement /3m Tape or suspended from the ceiling by means of SS chain of 8mm dia with anchor fasteners complete as required. All material shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. - PARKING SIGNAGES (ACP) SIZE - 400mm (L) X 400mm (HT)
509PARKING SIGNAGES (ACP) SIZE - 800mm (L) X 400mm (HT)
510PARKING SIGNAGES (ACP) SIZE - 1200mm (L) X 600mm (HT)
511LETTERS OF BUILDING NAME (INTERNAL) -APPASAHEB DHARMAADHIKARI DRAMA THEATRE, THANE.- Providing and fixing in position three dimensional building name using 18 gauge brush finish 316 grade stainless steel sheet lettering of width 50 mm x height 250 mm, projecting 50mm from the wall/partition/panelling and fixed at specified height in line and level by means of fully threaded stainless steel holdfast /studs which will be vertically welded to the back side of each letter. The stainless steel holdfast / studs will be inserted to the wall/partition/panelling by means of drilled holes and fixed with silicon for permanent fixing purpose and any other accessories etc. complete.All material shall be of approved make. All works complete as per the drawing/ Image, technical specification and direction of the Engineer.
512SIZE - 450MM (L) X 200MM (HT)- Providing & fixing in position signage's made from 4mm thick aluminium composite panel with computerized cut self adhesive vinyl graphic covered with clear vinyl to protect from peeling. The signage shall be fixed on wall with 12mm dia SS studs /mirror screws or hung from ceiling using stainless steel chains as per location. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
513SIZE - 750MM (L) X 600MM (HT)- Providing & fixing in position signage's made from 4mm thick aluminium composite panel with computerized cut self adhesive vinyl graphic covered with clear vinyl to protect from peeling. The board to be Mounted on 2\\" dia GI pipe of specified height ( If not specified 2.40 m from ground to top of board ) having a coat of metal primer and a coat of black enamel paint fixed in ground by using nominal grade of cement concrete as per location. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer. (Refer drawing number )
514SIZE – 1500MM (L) X 900MM (HT)- Providing & fixing in position signage's made from 4 mm thick aluminium composite panel of size 1500 mm(L)x 900mm(HT). The background of the panel should be pasted in retro reflective material, computerized cut, self adhesive film pasted on it. The board is to be fixed on wall with 12mm dia SS studs /mirror screws or mounted on 2 numbers of 2\\" dia GI pipe at specifeid height having a coat of metal primer with 2 or 3 coats of black enamel paint to get the required finish. Script for naming should be in English and Devnagri complete. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
515SIZE – 3600MM (L) X 1200MM (HT) - Providing & fixing in position signage's made from 4 mm thick aluminium composite panel of size 3600 mm(L)x 1200mm(HT). The background of the panel should be pasted in retro reflective material, computerized cut, self adhesive film pasted on it. The board is to be mounted on 2 numbers of 2\\" dia GI pipe at specifeid height having a coat of metal primer with 2 or 3 coats of black enamel paint to get the required finish. Script for naming should be in English and Devnagri complete. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
516SIZE OF THE THREE DIMENSIONAL LETTER : 100MM (W) X 450MM (HT)- Providing and fixing in position signage made up of 316 grade SS brush finish box type three dimensional letters having plate thickness 1 mm and the depth of the letter shall be 75mm, lettering of width 100 mm x height 450 mm and it will be fixed to the wall / RCC work at all heights in line and level by means of 6 mm dia fully threaded stainless steel holdfast which will be vertically welded/ threaded to the bottom side of the letter. The stainless steel holdfast will be inserted to the wall/RCC work by means of drilled holes and fixed with water proof adhesive for permanent fixing purpose and any other accessories approved by the engineer, with required staging .All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
517SIZE OF THE THREE DIMENSIONAL LETTER : 100MM (W) X 600MM (HT) Providing and fixing in position signage made up of 316 grade SS brush finish box type three dimensional letters having plate thickness 1 mm and the depth of the letter shall be 75mm, lettering of width 100 mm x height 600 mm and it will be fixed to the wall / RCC work at all heights in line and level by means of 6 mm dia fully threaded stainless steel holdfast which will be vertically welded/ threaded to the back side of the letter. The stainless steel holdfast will be inserted to the wall by means of drilled holes and fixed with silicon for permanent fixing purpose and any other accessories approved by the engineer, with required staging and scaffolding at the height of 20 meters from ground level. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
518SIZE OF THE THREE DIMENSIONAL LETTER : 300MM (W) X 2000MM (HT) -APPASAHEB DHARMAADHIKARI DRAMA THEATRE, THANE.- Providing and fixing in position signage made up of 316 grade SS brush finish box type three dimensional letters having plate thickness 3 mm and the depth of the letter shall be 250mm, lettering of width 300 mm x height 2000 mm and it will be fixed to the wall / RCC work at all heights in line and level by means of 12/18/25 mm dia fully threaded stainless steel holdfast which will be vertically welded/ threaded to the back side of the letter. The stainless steel holdfast will be inserted to the wall by means of drilled holes and fixed with silicon for permanent fixing purpose and any other accessories approved by the engineer, with required staging and scaffolding at the height of 23 meters from ground level. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
519TEXTURE PAINT- Providing and applying Textured paint of approved texture and colour (Archi Concrete/Torino Asian Paints or equivalent) for internal walls/surfaces which includes preparing the surface, applying primer, putty & paint to required number of coats to achieve desired texture & applying protective coat to give a finish acceptable to the engineer and any additional coats if required shall be at the cost of the contractor, as per manufacturers specification and technical manual including required cleaning of the surfaces, curing etc. complete to the entire satisfaction of the Engineer. Rate shall be inclusive of surface preparation to line & level with all necessary tools & tackles, etc. maintaining proper line, level and grooves. All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
520MAIN STAGE CURTAIN - Providing and fixing in position Acrylic velvet main stage curtain of 16 m x 6.5 m in size in two pieces of approved colour, shade, make and manufacturer & as per requirement with overlap at center and with 50 % folds with minimum 125 mm ( 5'' ) satin boarder at bottom. The satin lining to be provided on back side of main curtain and fringe of size of minimum 80 mm ( 3'' ) or as per requirement to be provided for zalar. The curtain should be suspended from track of runners suspended by 25 mm ( 1'' ) M. S. rings and weights at the bottom of curtain. The curtain to be fixed with all necessary arrangement as per site condition with all taxes etc. complete. as per detailed design, drawing & Spec. As directed by Engineer in Charge.All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
521MAIN CURTAIN VALANCE - Providing, Fixing, in position of MAIN CURTAIN VALANCE Main Valance In Velvet 16.0 x 1.20 mtrs. Lining, Stitching Charges, Navar Belt and other, M.S. Pipe, Fitting Charges.( Fabric FR Grade) with necessary scaffolding as per Architectural & Acoustical Design & Instructions Complete in all aspects.All the materials shall be of approved make. All works complete as per the drawing, specification and direction of the Engineer.
522MAIN CURTAIN -TRACK- Providing, Fixing, in position of MAIN CURTAIN -Track Main curtain sliding MS track with runners and pulleys including cost of necessary Scaffoldings per Architectural & Acoustical Design & Instructions & Complete in all aspects.
523INTERNAL VALANCE- Providing, Fixing, in position of INTERNAL VALANCE- Internal blue valance size16.00 x 1.2 mtrs including cost of necessary scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
524SIDEWINGS - Providing, Fixing, in position of SIDEWINGS IN SINGLE COLOUR CLOTH- Side wings made in deodar wood / MS of size 75mmx 40mm dark blue fabric on both sides with complete wing guides and rails - size 5.00 x 1.20 mtrs ( Fabric FR Grade)as per Architectural & Acoustical Design & Instructions & Complete in all aspects. (Refer drawing number – CC-IN-501,CC-IN-502,CC-IN-503,CC-IN-504,CC-IN-505)
525MIC AND LIGHT BARS- Providing, Fixing, in position of mic and Light bars with all accessories - Including cost of necessary scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
526CYCLORAMA CURTAIN- Providing, Fixing, in position of CYCLORAMA CURTAIN- Cyclorama curtain size 15.0m x 6.5 mtrs drop type with GI pipes complete .( Fabric FR Griade) including cost of necessary scaffolding as per Architectural & Acoustical Design & Instructions Complete in all aspects.
527MIDDLE CURTAIN- Providing, Fixing, in position of MIDDLE CURTAIN -16.0x6.5mtrs drop type with GI pipes complete .( Fabric FR Grade) including cost of necessary scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
528BACK CURTAIN- Providing, Fixing, in position of BACK CURTAIN - 16.00x 6.5mtrs drop type with GI pipes complete . ( Fabric FR Grade) including cost of necessary scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
529HAND OPERATED GEAR ARRANGEMENT- Providing, Fixing, in position of Hand OPERATED GEAR ARRANGEMENT for frills etc with top rolling stands pulleys , drum pedestal , bearings and wire ropes complete with fitting as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
530MAIN CURTAIN COMPLETE MECHANISM MOTOR & ACCESSORIES- Providing, Fixing, in position Motorized mechanism for operation of main Velvet curtain with gair box , 1 Hp motor Crompton make as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
531Automatic OPERATED GEAR ARRANGEMENT- Providing, Fixing, in position of Automatic OPERATED GEAR ARRANGEMENT Automatic gear box for top rolling stands pulleys , drum pedestal , bearings and wire ropes complete with fitting as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
532FABRICATING STAGE MANDAP- Providing & Fabricating Stage Mandap including cost of necessary scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.
533Providing and supplying folding platform of sizes as mentioned below in Deodar frame of 100mm x 35mm size, covered on all sides with 6mm plywood and top to be covered by 25mm thick Deodar wood planks Including all necessary arrangement , labour, taxes, Transport etc complete. as per detailed design drawing & speci. as directed by Engineer in Charge. A) Size 1.83 x 1.20 x 0.45 m (6' x 4' x 1' 6\\")
534B) Size 1.83 x 1.20 x 0.230 m ( 6' x 4' x 9\\")
535C) Size 1.83 x 0.90 x 0.45 m ( 6' x 3' x 1'-6\\" )
536D) Size 1.83 x 0.90 x 0.230 m ( 6' x 3' x 9\\")
537E) Size 1.20 x 1.20 x 0.600 m ( 4' x 4' x 2')
538ROSTRUM- Providing making and supplying Rostrum speech table of required size made in 19mm ply wood with laminated finish and height of 1.07 m (3' - 6\\" ) complete Including all material ,necessary arrangement , labour, taxes, etc. complete.as per details & directed by Engineer -incharge.
539Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 55kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conformingto IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation on with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
540Supplying, installation, testing and commissioning of main fire pump (MFP / EP) suitable for water discharge of 2280 to 2850LPM at 80 to 60 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 45kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal/split casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/EP
541Supplying, installation, testing and commissioning of main fire pump (MFP/DP) suitable for water discharge of 2280 to 2850 LPM at 90 to 60 m head driven by 76 HP or suitable HP capacity diesel engine at required working speed suitable for manual/automatic operation and consisting of following :(a) Horizontal type, single stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft(SS410 grade), mechanical seal conforming to IS 1520.(b) Water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12/24 volts DC electric starting equipment with battery of required AH capacity with necessary charger suitable to work on 230v, 50Hz AC supply, diesel tank of minimum 150ltr capacity with first filling of diesel up to 100% level with necessary piping with valves up to engine , exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications etc. as required.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with engine assembly and accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/SSC/DP
542Supplying, installation, testing and commissioning of jockey fire pump (JP) suitable for water discharge of 180 to 240 LPM at 90 to 70 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of 9.3 kW or of suitable kW capacity for manual/automatic operation and consisting of following :(a) Horizontal/ vertical type, multi stage, centrifugal casing pump of cast iron body & bronze impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning, proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/JP
543Supplying and erecting G.I. pipe ‘C’ class ERW 25 mm dia with necessaryfittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
544Supplying and erecting G.I. pipe ‘C’ class ERW 32 mm dia with necessaryfittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
545Supplying and erecting G.I. pipe ‘C’ class ERW 40 mm dia with necessaryfittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
546Supplying and erecting G.I. pipe ‘C’ class ERW 50 mm dia with necessaryfittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
547Supplying and erecting G.I. pipe ‘C’ class ERW 65 mm dia with necessaryfittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
548Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
549Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
550Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
551Supplying and erecting G.I. pipe ‘C’ class ERW 200 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP
552Providing coating of bitumen paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick wrapping for underground 100 mm ring main of fire fighting system.(Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass).
553Providing coating of bitumen paint & pipeline corrosion resistant Pypkote tape conforming to IS 10221 Appendix B specification having 4mm thick wrapping for underground 150 mm ring main of fire fighting system.(Pypkote tape comprises of a Tar based Polymeric mix supported on a fabric of high tensile strength Fibreglass).
554Supplying and erecting 50 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
555Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
556Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
557Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
558Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV
559Supplying and erecting 25 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
560Supplying and erecting 50 mm dia gun metal gate valve complete with PN16 pressure rating, as per specification no. FF-VL/GV
561Supplying, installing, testing & commissioning of double flange Non Return Valve PN 10 class of 50 mm dia. Conforming to IS: 5312 (Part-I), Universal mounting (Hroz/Vert) having CI to IS 210Gr260 Body and Bronze IS318 Gr LTB Disc with nut bolts to IS 1363 PT1 Class 4.6, Gaskets & Body ring Nitrile to IS:638 Type B, fasteners, etc. and tested to 1.5 times of working pressure in an approved manner. Refer Technical Specifications
562Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
563Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV
564Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
565Supplying, installing, testing and commissioning of Rubber Expansion Bellows of 200mm Deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge.
566Supplying, installing, testing and commissioning of Rubber Expansion Bellows of 150mm Deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge.
567Supplying, installing, testing and commissioning of Rubber Expansion Bellows of 80mm Deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge.
568Supplying, installing, testing and commissioning of Rubber Expansion Bellows of 50mm Deg C temp., Axial/ Lateral/ Torsional- flexibility, pressure range-16 Mpa including nuts, bolts and washers complete as required. complete as directed & specified as per the direction of engineer in charge.
569Supplying and erecting 200 mm dia Cast Iron end line strainer of Y-type flanged end pattern, PN16 pressure rating, SS screen, end connection with Flanged / Screwed / Socket Weld / Butt Weld End etc with standard OAR (open area Ratio) for positive suction complete as per specification no. FF-VL/ELS
570Supplying and erecting 300 mm dia 1.5m in height air vessel / tank fabricated from min 5mm thick M.S. sheet complete as per specification no. FF-FFA/ACT
571Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC
572Supplying and erecting fire brigade header ( Siamese connection ) of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FMC
573Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
574Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
575Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body.
576Supplying and erecting M.S./CRCA cabinet for housing double hose pipe with nozzle (size 750 x 600x 250 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)
577Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV
578Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
579Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FFFFA/ NZ
580Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
581Supplying, erecting, testing and commissioning of Upright/ Pendent quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR./UP
582Supplying, erecting, testing and commissioning of Pendent quartzoid bulb sprinkler, 15 mm (½\\") dia. NBCM Body chrome finished, 79º C fixed temperature rating with deflector disc of conventional construction complete.
583Supplying erecting, testing and commissioning of sprinkler flexible pipe of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of 1000 mm size (UL Listed) complete as required as per specification no. FF-SPR/FHP
584Supplying, erecting, testing and commissioning vane type water flow detector 80 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. as per specification no. FFSPR/WFD
585Supplying, erecting, testing and commissioning vane type water flow detector 100 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. as per specification no. FFSPR/WFD
586Supplying, erecting, testing and commissioning vane type water flow detector 150 mm dia. with 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes. as per specification no. FFSPR/WFD
587Supplying, installing, testing and commissioning of Ready-made Test and Drain valve of 50 mm dia threaded brass body, ball type, suitable to k-factor 80, sight glass, between sprinkler header & 50 mm dia. drainage line including piping connections, cutting, threading etc, complete as required.
588Supplying and erecting, testing and commissioning of 150 mm dia. installation control valve (Alarm Valve) of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch,cock valve complete with drain valve and bypass, test control box, ball valves, MS pipes of required size, flanges, orifice plate, gasket etc. complete as per specification no. FF-VL/ICV
589Supplying and fixing of self expanding, ready to use polyurethane (PU) foam sealant of minimum 750ml bottle, suitable to seal the openings of all kinds of cables, pipes and cable support system in steel, aluminium and plastic profiles (except hollow core conductors). Sealant shall have minimum 2 hour fire rating , conforming to EN 1366-4:2021 as per specification no FF-FRS.
590Excavating Hard murum/Stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
591Supplying, Installing, Testing and Commissioning of ceiling mounted Automatic UL listed FE 36 Clean Agent Modular Type Automaic Fire Extinguisher 10 kG capacity, nitrogen propelled operating pressuree 15 bar, MS cylinder MIG welded sheet 2 mm sheet & 50 micron epoxy coated in shade 538 of IS:5, forged brass 57 / 68 Deg C detector & nozzle, 10-15 second discharge time for 85%, 3 M from floor or 1 M above risk requiring 10 kG per 5 SqM, complete with ceiling mounted brackets suitable for weight of the unit. (Server Room & Electrical Rooms)Refer Technical Specifications
592Supplying, installing, testing & commissioning of horizontal, vertical spray down type Water Curtain Nozzles of K30, 0.5bar to 3.5 bar, fan shaped spray pattern, 5.5 m linear coverage one side, spaced at 2.5 M, along with all accessories for complete functioning of water curtain system.Refer Technical Specifications
593Supplying, installing, testing & commissioning of Deluge Valve of 80 mm dia, Ductile Iron-ASTM A 536, Double Flange, Wet Pilot, Vertical mounting, Basic Wet Pilot Trim, Electrical Solenoid Vlve Trim with Test & Alarm Trim and Drip & Drain Trim & companion matching flanges & fasteners.Refer Technical Specifications
594Supplying , erecting & terminating XLPE insulated, galvanised steel Roundwire armoured cable 11 kV(E), 3 x 300 sq. mm. aluminium conductorlaid in provided trench / pipe as per specification no. CB-HT
595Supplying , erecting & terminating XLPE insulated, galvanised steel formedwire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductorlaid in provided trench / pipe as per specification no. CB-HT
596Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E )XLPE HT cable 3x240 to 300 sq. mm. with necessary material as perspecification no. CB-JT/HT
597Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as perspecification no. CB-JT/HT
598Providing and erecting Heat shrinkable straight through joint kit for 11 kV (E) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT
599Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosingXLPE armoured cable on wall/pole as per specification no. CB-CE
600Supplying & laying (including excavation) half round reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
601Excavating hard Rock or bituminous road by chiselling for preparing pit forpole / stay/earth plate / for laying cable/ pipe & clearing the site by removingdebris & making the site as required complete.
602Supplying, erecting, testing and commissioning 11KV HT metering cubicle(compact/vertical type) approved by licensee fabricated with 2 mm (14 SWG)M.S. sheets with supporting angle, painted with powder coating / epoxy paint ofrequired shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, withcounter meter for measuring no of times the opening of meter door, top sidecover (CT, PT cover) interlock with meter door, epoxy casted 3 nos CT havingrequired ratio between 50/5A to 200/5A, VA10 or 15, Class 0.2S, epoxy casted 3nos PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for providedtrivector meter, and provision for incoming and outgoing cables complete dulytested by licensee with necessary test certificates and erected on provided plinth/cc foundation as per specification no. CP-HT.
603Supplying & erecting cast iron cable indicator plate buried along with route ofcable for PVC / XLPE armoured cable as per specification No. CB-CIP
604Supplying, erecting, testing & commissioning 11kV, 630A, 21kA/3sec, 1 way Indoor/outdoor, extensible motorised SCADA compatible RMU, internal arc tested consisting of 1 no. feeder with 1 LBS compliant to IEC 62271-100, 200 and 102 as per specification no. SW-HTS/RMU SCADA.
605Supplying, erecting, testing & commissioning 11kV,630A,21kA/3sec,4 way outdoor,extensible motorised SCADA compatible RMU, internal arc tested consisting of 2nos. feeder with 2LBS and 2nos. feeder with 2VCB compliant to IEC62271-100,200and 102, as per specification no. SW-HTS/RMU SCADA.
606Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 800 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound, without gas cushioning, hermetically Sealed transformer, delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with on load tap changer + RTCC +AVR) on load +5 to-15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 2147 Watts at 50% load, 5838 Watts at 100% load as per IS:1180 (part 1) : 2014 -Ammendment 4 -2021 ENEGRY EFFICIENCY LEVEL 2, with necessary permissions of Electrical Inspector, With all accessories complete.
607Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 1250 kVA, Mineral oil immersed and naturally cooled outdoor type, Copper wound, without gas cushioning, hermetically Sealed transformer, delta/star connected additional neutral brought out on load side, temperature rise should not exceed 45℃ by thermometer in oil and 50℃ by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with on load tap changer + RTCC +AVR) on load +5 to-15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 3220 Watts at 50% load, 8400 Watts at 100% load as per IS:1180 (part 1) : 2014-Ammendment 4 -2021 ENEGRY EFFICIENCY LEVEL 2 with necessary permissions of Electrical Inspector,With all accessories complete.
608Supplying, erecting, testing and commissioning of diesel generating set withalternator of 750 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinderdiesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hourin 12 hours, along with standard accessories, self-excited, self-regulated, screenprotected alternator with static excitation system running at 1500 RPM as per IS4722-2001 with voltage regulation +/- 5 %, with performance class G3 andmaximum fuel consumption 126.4 ltr/hr @75% loading. Both the engine andalternator direct coupled on a common fabricated steel base frame and mountedon anti-vibrating pads, with standard control panel comprising meters,switchgears, indicators connected with suitable wires/cables, the complete setenclosed in composite acoustic enclosure as fully assembled integral unit made of16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75dB at 1.0 m, provided with first filling of oil, diesel not less than 990 ltr etc., onprovided M20 grade CC foundation and obtaining necessary approval fromElectrical Inspector.As per CPCB norms 4+.
609Supplying, erecting, testing and commissioning of microprocessor basedgenerator control unit (synchronization) panel suitable for diesel generatingset of above 500 kVA upto 750 kVA capacity 3 phase, 415 V, 50 Hz, A.C. supplywith all standard features and safeties etc as per specification no. GEN-SYNC.(Refer SLD for More details)
610Supply, Installation, testing & commissioning of ( Considering 40 Mtr tall DG set Exhaust chimney structure) (For 2 nos of 750 kVA DG Sets) Standard Light Class GI pipe of 40 m length including AL Cladding,Insulation .And Standard Light Class GI pipe with provision of 2 inlets of suitable Dia. in mm from 2 nos. 750 kVA DG sets at 1-3m to horizontal & connection thereof on readymade provided foundation to suit contractor’s designed based on Static Load & Dynamic Load, in Seismic Zone III & Suitable kmph wind in West direction. (Includes Box Structure ,Exhaust pipe, cladding, Insulation, accessories but Without Foundation etc.)
611Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
612Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
613Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. withnecessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
614Supplying and laying HMS PVC conduit FRLS grade 32mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
615Supplying & erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW
616Supplying & erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW
617Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
618Supplying & erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
619Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
620Supplying & erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW
621Supplying & erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW
622Supplying & erecting mains with 2x6 sq.mm FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/bus bars or any other placesas per specification no. WG-MA/BW
623Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board.
624Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
625Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete.
626Supplying and erecting modular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete.
627Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete.
628Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
629Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete
630Supplying and erecting modular type buzzer 220 / 250V, duly erected on provided plate and box with wiring connections complete.
631Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
632Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.
633Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
634Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
635Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
636Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
637Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
638Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly flushed to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
639Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
640Supplying and erecting 6 to 32A, 10kA, SPMCB suitable to fix in 1 module ofmodular switch in provided box complete & duly concealed with necessarymaterial and connected.
641Supplying and erecting 16 to 32A, 10kA, DPMCB suitable to fix in 2 moduleof modular switch in provided box complete & duly concealed with necessarymaterial and connected.
642Point wiring for light/bell concealed type in min 20 mm HMS PVC conduitwith 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch,earthing and required accessories as per specification no. WG-PW/CW
643Point wiring for light/bell concealed type in min 20 mm HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, Control through modular SP 10 A MCB, earthing and required accessories .(Excluding MCB Cost)
644Point wiring for ceiling fan concealed type in min 20 mm HMS PVCconduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular typeswitch, earthing and required accessories as per specification no. WG-PW/CW
645Point wiring for light/bell hybrid type (surface type under false ceiling andconcealed type for drops & switch boards on walls) in min 20 mm HMS PVCconduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modular type switch, earthing and required accessories as per specification no.WG-HW
646Point wiring for ceiling fan hybrid type (surface type under false ceiling andconcealed type for drops & switch boards on walls) in min 20 mm HMS PVCconduit / casing n caping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modular type switch, earthing and required accessories as per specification no.WG-HW
647Point wiring for light/bell hybrid type (surface type under false ceiling andconcealed type for drops & switch boards on walls) in min 20 mm HMS PVCconduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires,modular type switch, earthing and required accessories as per specification no.WG-HW Note : -3)For point wiring with 2 way control point increase overall rate by 50% of point wiring.
648Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping)with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch,earthing and required accessories as per specification no. WG-PW/SW
649Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm(2+1E) FRLSH grade copper wire, modular type switch, earthing and requiredaccessories as per specification no. WG-PW/SW
650Secondary point wiring for additional light/bell point, concealed type in min20 mm PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires withrequired accessories as per specification no. WG-PW/CW
651Secondary point wiring for additional light/bell point in min 20mm PVCconduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with requiredaccessories as per specification no. WG-PW/SW
652Supplying and erecting LED square / circular Max. 7W down lighter / PanelLight having pressure die-cast aluminium housing, polystyrene diffuser havingsystem lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W,CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV,Life class of 50,000 Hrs at L70B50 including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with minimum 2 years warranty as per specification No. FG-IDF/LED.
653Supplying and erecting LED square / circular Max. 11 W down lighter/PanelLight having pressure die-cast aluminium housing, polystyrene diffuser havingsystem lumens output of Min. 1200 Lumens, min. efficacy of 110 lumen/W,CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV,Life class of 50,000 Hrs at L70B50 including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with minimum 2 years warranty as per specification No. FG-IDF/LED.
654Supplying and erecting LED square / circular Max. 14 W down lighter /Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 1500 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5kV, Life class of 50,000 Hrs at L70B50 including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with minimum 2 years warranty as per specification No. FG-IDF/LED.
655Supplying and erecting LED square / circular Max. 18 W down lighter /Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2000 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5kV, Life class of 50,000 Hrs at L70B0 including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with minimum 2 years warranty as per specification No. FG-IDF/LED.
656Supplying and erecting LED square / circular Max. 25 W down lighter /Panel Light having pressure die-cast aluminium housing, polystyrene diffuserhaving system lumens output of Min. 2750 Lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5kV, Life class of 50,000 Hrs at L70B50 including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with minimum 2 years warranty as per specification No. FG-IDF/LED.
657Supplying and erecting LED Strip light Max. 45 W IP20 class having minimumlumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCTupto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of230-270V, Life class of 30,000 Hrs at L70B50 including driver with minimum 1year warranty as per specification No. FG-IDF/LED.
658Supply and installation of aluminium profile housing for surface mounting of LED strip with minimum thickness of 1mm and shall installed with screws.on the surface. The housing shall be designed according to dimensions required for LED strip.
659Supplying and erecting Bulk Head LED fitting Max. 10W with high transitivitydiffuser with system lumens output of Min. 1100 lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%,p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Lifeclass of 50,000 Hrs at L70B50, IP66, IK09 rated including driver IP66, IK09rated on provided PVC Block / wooden board with minimum 2 years warranty asper specification No. FG-IDF/LED.
660Supplying and erecting anodized aluminium mirror light LED fitting (2 feet)Max. 12W with high transitivity diffuser with min. system lumens output of 1200lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angleof 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V,surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver withend caps on provided PVC Block / wooded board with minimum 2 yearswarranty as per specification No. FG-IDF/LED.
661Supplying and erecting CRCA powder coated mirror light LED fitting (4 feet)Max. 17W with high transitivity diffuser with system lumens output of Min. 2000lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angleof 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V,surge protection of 4 kV, Life class of 50,000 Hrs at L70B50, IP 20 ratedincluding driver with end caps on provided PVC Block / wooded board withminimum 2 years warranty as per specification No. FG-IDF/LED.
662Supplying and erecting CRCA powder coated light LED fitting (4 feet) Max.33W with high transitivity diffuser with system lumens output of Min. 4000lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angleof 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V,surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 , IP20 ratedincluding driver with end caps on provided PVC Block / wooded board withminimum 2 years warranty as per specification No. FG-IDF/LED.
663Supplying & erecting inverter LED batten 20W tube light fitting withpolycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600mA Lithium ion Battery with charging time of 8-10 Hours and backup time ofMin. 3 Hrs with minimum 25% of initial Watts having luminous efficacy of 100lumen/watt, CRI>80, CCT of 6500K and THD<=20 % having useful life ofminimum 25000 Hrs with over heat protection with minimum 2 years as perspecification No. FG-IDF/LED.
664Supplying & erecting UV Fly killer/ bug catcher Light Fitting having 2 X 20WUV Tube Lights to cover min. area of 500 sq.ft with powdered coated M.S. / steelbody suitable to work on 230V, AC supply having top mounting arrangementwith SS chain complete and 3 core flexible wire upto 1 mtr with minimum 1 yearwarranty as per specification No. FG-IDF/LED.(Cafe+ Kitchen)
665Supplying and erecting integrated LED street light fitting 40 to 50W IP65 &IK08 class having single piece pressure die-cast aluminium housing, havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W,CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V,inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 includingdriver complete with minimum 2 Years warranty as per specification No. FGODF/SL.
666Supplying and erecting integrated LED street light fitting 60W IP65 & IK08class having single piece pressure die-cast aluminium housing, having systemlumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuiltsurge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including drivercomplete with minimum 2 Years warranty as per specification No. FG-ODF/SL.
667Supplying and erecting integrated LED flood light fitting Max. 30W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 3000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with Ushaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL.
668Supplying and erecting integrated LED flood light fitting Max. 70W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with Ushaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL.
669Supplying and erecting integrated LED flood light fitting Max. 100W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with Ushaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL.
670Supplying and erecting Concealed type foot/step light Max. 5W having IP67, IK10 rated Pressure die cast housing having system lumens output of Min. 500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, SDCM<5, p.f. >0.95, operating range of 230-270V, surge protection of 2.5 kV, Life class of 25,000 Hrs at L70B50, including driver by making necessary arrangement / recess in wall to make it flush with surface with minimum 2 Year warranty.
671Supplying and erecting integrated LED Highbay Fitting 135W IP65 & IK08class having die cast aluminium housing with polycarbonate diffuser withintegrated optics, having system lumens output of Min. 20000 Lumens, min.efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90,operating range of 140-240V, inbuilt surge protection of 4kV, Life class of 50,000Hrs at L50B50 , including driver complete with 2 Year warranty as perspecification No. FG-ODF/LED.
672Supplying and erecting Recess mounted 30W LED Wall Washers, tilted 70 Degree Outwards and Swivels 360 Degree to offer best illumination on the wall with any colur with driver complete.(Including Compatible Driver)
673Supplying and erecting Recessed LED square / circular Max. 3W down lighter Tiltable Light having pressure die-cast aluminium housing, polystyrene diffuser, High Efficiency reflector, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 15 to 90 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 2 years warranty.
674Supplying and erecting Deep Recessed LED square / circular Max. 6W down lighter having pressure die-cast aluminium housing, polystyrene diffuser, High Efficiency reflector, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 15 to 90 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 2 years warranty.
675Supplying and erecting Deep Recessed LED square / circular Max. 10 W down lighter having pressure die-cast aluminium housing, polystyrene diffuser, High Efficiency reflector, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 15 to 90 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 2 years warranty.
676Supplying,installation,testing,commisioning of suspended type Decorative Chandelier having sparkling crystals crafted in a beautiful gold colour ,Colour -ABS plated imitation gold + Class A Clear Crystal, Material -Metal, ABS & Class A Clear Crystal, suitable for Reception Lobby,6Nos. x 40W Light Fittings, CCT- 3000 to 5700k, with all Accessories(Dimension Dia. x Ht:-Dia. 510 x H 1910 in mm)
677Supplying and erecting 25 W wall mounted COB LED Up downlight IP 66 having Extruded and Die cast aluminium housing with high corrosion resistance surface finish with Integral control gear,Driver and beam angles - narrow, medium, wide ,Complete with all required accessories .
678Supplying and erecting of 1 meter magnetic Track(Aluminium) with 2 nos. recessed or Hanging or surface track light 7-8 W,3000k to 6500k (Beam Angle -Wide/Narrow beam),100 lm/W, CRI=>80,IP 20, 220-240V, Includes Driver, With accessories such as Connector,Jointer, Hanging Wire etc.
679Supplying,installation,testing,commisioning of Outdoor type LED square / Circular/trapezoidal design, 36 W hanging with dome AL cover(with any colour finishing) from surface or equivalent type Light having provision of hanging and accesories with inbuilt driver & including Lamp, 100 Lumens/w ,3000 to 5700k Accesories for Hanging shall be part of the fitting (mounting height from ceiling upto 1.5 meter).With 2 years warranty.Similar to Pasolite Pavilion pendents-PD 004-E 27.
680Supplying and erecting IP 67 NEON LED Flex light Max. 10W/m W IP20 class having minimum lumens output of 800 Lumens/m, min. efficacy of 90 lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f. >0.95, operating range of 230-270V, Life class of 30,000 Hrs at L70B50 including driver with minimum 1 year warranty ,Include all accessories such as Tape etc.Similar to Pasolite Neon Flex-PONF 01.
681Supplying and erecting Outdoor type(IP65) 15 to 18 W LED Tree uplighter fitting ,24VDC, die-cast aluminum housing,suitable watts driver, / power supply (if any),including gear box(With spike) .Complete with all accessories and Coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint similar to K light model no K-28306 Nebula Mini or Pasolite Garden Light POGS 08.
682Supplying and erecting luminous / modular type call bell indicator withplastic body, heavy duty coil and indicator lamp working on 230V A.C. supplywith resetting arrangement complete erected on double wooden / sunmicaboard.
683Supplying & erecting aviation obstruction light minimum up to 48 watt consisting of yellow painted die-cast aluminium alloy housing with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure complete as per specification No. FG-AV.
684Supplying,installation,testing,commisioning of 44W ,100LM/W ,Recessed mounted 50mm aluminium extruded linear lighting luminaires with white powder coated finish,with all mounting and connecting accessories.
685Supplying and erecting Deep Recessed LED square / circular Max. 15W down lighter having pressure die-cast aluminium housing, polystyrene/Polycarbonate diffuser, High Efficiency reflector, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 15 to 90 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete .
686Supplying and erecting Deep Recessed LED square / circular Max. 30W down lighter having pressure die-cast aluminium housing, polystyrene/Polycarbonate diffuser, High Efficiency reflector, min. efficacy of 115 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 15 to 90 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete .
687Supplying and erecting Deep Recessed LED square / circular Max. 30W Dali Dimmable COBdown lighter having pressure die-cast aluminium housing, polystyrene/Polycarbonate diffuser, High Efficiency reflector, min. efficacy of 115 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 15 to 90 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete .
688SITC of management software, user friendly master control and reporting software, utilises site plans as floor plans backdrops for ease of navigation. Preset scenes can recalled programmed, time clock allows one time and recurring events to be easily schedule,Lamp Maintenance,Live Monitoring,Zoning,Reporting. Network Gateway to provide integration between the control systems and Ethernet networks. The device supports the TCP/IP protocol, with static or DHCP assigned IP addressing. An integral webserver allows Browser based control scenarios. The interface incorporates a Programmable Logic Controller that can process comprehensive conditional and sequential logic and arithmetic functions. Power: 15V DC supplied by the control system network at 200mA .Network Power Supply. Power: 15V DC 1.5 Amps regulated power supply, designed to supplement the network DC supply. Supply of 110-240V ±14% 50/60Hz Single Phase at 0.25A The switchmode design allows the device to be used with a wide range of supply voltages without the need for a manual selector setting. Size of six-unit DIN-rail mount enclosure that has a circuit breaker profile. This enables the device to be installed in all types of electrical equipment enclosures, including those with cover apertures specifically designed for circuit breakers. 8 Channel dali dimming module & relay controller to control any type of switched load. The power circuit is a “feed-through” design and is electrically equivalent to a 12-pole contactor. DIN-rail mountable & each channel is fitted with a hardware override switch which is accessible from the front panel. Control Supply: 100-240V 50/60Hz Single Phase at 0.25A, Outputs: 4 x Switched feed thru outputs at 20A (Resistive) Max total box load 180A. Dc Supply: 12V @ 120mA, Preset Scenes: 170, Operating Environment: 0º to 50ºC ambient temperature, 0% to 95% RH non-condensing.Antumbra Push type 6 key User Interface White with White Rim with Fully programmable options for Indivuidual control / group control / Scene control / Tasks etc. Wall mounted on 2M (3 X 3 size) modular box. Front cover black with Backlight, built in proximity and Loaded icons like presentation scenario, meeting scenario, master On/ Off, Powersaving mode etc along with a LED indicator for each operations. Custom engraving facility. Operating on 12V DC @ 40-50mA from Dynet network. Includes Cabling /cat 5 work also.
689Supplying and erecting Energy Saving Ceiling fan of 3 star rating as per BEE230 V A.C. 50 cycles 1200 mm complete erected in position as per specificationno. FG-FN/CF
690Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W)of Min. 8 , PF>0.9, THD<10% with IR remote control, Temperature Rise ofMax. 40 deg.C, having external mounted control PCB completely erected inposition as per specification no. FG-FN/CF
691Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x75 mm long with necessary materials for ceiling fan.
692Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. roundbar and painted.
693Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to theR.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thickaluminium/M.S. Bowl 100 mm dia. or equivalent square size and having depthupto 75 mm complete erected with duly painted by one coat of red oxide paintand two coats of paint erected in position and without any leakage of slurry ofcement concrete on either side of the box and positioned to the bottom level ofthe slab.
694Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly paintedfor fan complete erected with PVC three core flexible cable 1 sq. mm copperPVC wire.
695Supplying,erecting, testing & commisioning of 20 kVA capacity on line puresine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,3 phase input &3phase output complete with all protections as per specification no. AP-UPS(Without batteries)(60 min . Backup)
696Supplying and erecting 12 V/42Ah SMF battery with battery terminal wire, dulycharged complete with 24 months warranty complete
697SITC of Parallel Kit for 4 nos. of 20kVA UPS.
698Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more details MAIN LT Feeder Pillar-1,IP65Near SS, Include Thermostat with heaters.Incomer Incomer -1 (Grid Incoming Feeder) 1 Nos. -2000 A, FP ACB, 50kA, with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised type,RPRBus-bar 415V,TPN,50Hz,2000 A Al BusbarOutgoing1 No.1000 A TPN ACB Microprocessor LSI release and with indication lamps1 No.1600A TPN ACB Microprocessor LSI release and with indication lamps1 No.2000 A TPN ACB Microprocessor LSI release and with indication lampsRest details as per SLD
699Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsMAIN LT Feeder Pillar-2,IP65Near SS, Include Thermostat with heaters.Incomer Incomer -1 (Grid Incoming Feeder) 1 Nos. -1250 A, FP ACB, 50kA, with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised type,RPRRest details as per SLD
700Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more details MAIN LT PANEL-1 & 2,IP54@ Upper Ground Floor Include Thermostat with heaters.Incomer Incomer -1 (Grid Incoming Feeder) 1 Nos. -2000 A, FP ACB, 50kA, with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised typeIncomer -1 (DG set Incoming Feeder) 1 Nos. -2000 A, FP ACB, 50kA, with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised typeBus-bar 415V,TPN,50Hz,2000 A Al BusbarOutgoing2- Nos.1000 A TPN ACB Microprocessor LSI release and with indication lamps3nos.-TP+N 630 A-MCCB with Microprocessor LSI release and with indication lamps1nos.-TP+N 250 A-MCCB with TM release and with indication lamps3nos.-TP+N 160A-MCCB with TMR and with indication lamps1nos.-TP+N 100A-MCCB with TMR and with indication lamps1no.-TP+N 100A-MCCB with TMR and with indication lamps+ SPD Device Type A+BBUS Coupler1 Nos. -2000 A, FP ACB, 50kA, with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised typeBus-bar 415V,TPN,50Hz,1250 A Al Busbar2- Nos.1000 A TPN ACB Microprocessor LSI release and with indication lamps2nos.-TP+N 630 A-MCCB with Microprocessor LSI release and with indication lamps1nos.-TP+N 400 A-MCCB with Microprocessor LSI release and with indication lamps3nos.-TP+N 200A-MCCB with TMR and with indication lamps1nos.-TP+N 100A-MCCB with TMR and with indication lamps1no.-TP+N 100A-MCCB with TMR and with indication lamps+ SPD Device Type A+BRest details as per SLD
701Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsUtility LT PANEL-1,IP54@ Upper Ground Floor Include Thermostat with heaters.Incomer Incomer -1 (Grid Incoming Feeder) 1 Nos. -1000 A, FP ACB, 50kA,with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised typeBus-bar 415V,TPN,50Hz,1000 A Al BusbarOutgoing2no.-TP+N 630 A-MCCB with Microprocessor LSI release and with indication lamps1no.-TP+N 100A-MCCB with TMR and with indication lamps9 no.-32-63 A TPN MCCBRest details as per SLD
702Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsEMERGENCY LT PANEL-1,IP54,36kA@ Upper Ground Floor Include Thermostat with heaters.Incomer Incomer -1 (Grid Incoming Feeder) 1 Nos. -1600 A, FP ACB, 50kA, with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised typeIncomer -1 (DG set Incoming Feeder) 1 Nos. -1600 A, FP ACB, 50kA, with Microprocessor release having LSIG settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, MFM with RS485, Motorised typeBus-bar 415V,TPN,50Hz,1600 A Al BusbarOutgoing2 Nos. -1000 A, FP ACB, 50kA,with Microprocessor release having LSI settings. Potential free Contacts for ON, OFF, TRIP Signal - 1 No., RYB Indications, Motorised type1no.-TP+N 320 A-MCCB with Microprocessor release having LSI and with indication lamps3no.-TP+N 250 A-MCCB with TMR and with indication lamps7no.-TP+N 100A-MCCB with TMR and with indication lamps1no.-TP+N 100A-MCCB with TMR and with indication lamps+ SPD Device Type A+BRest details as per SLD
703Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsGF CONV. HALL LT PANEL-1,IP54@ Ground Floor and FF CONV. HALL LT PANEL-1,IP54 Include Thermostat with heaters.@ Ground FloorIncomer Incomer -1 (Grid Incoming Feeder) 1no.-TP+N 200 A-MCCB with TMR and with indication lamps,MFMBus-bar 415V,TPN,50Hz,200 A Al BusbarOutgoing2no.-TP+N 100A-MCCB with TMR and with indication lamps3 no.-40-100 A TPN MCB with TMR and with indication lamps6 no.-32-100 A TPN MCB with TMR and with indication lampsRest details as per SLD
704Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsSF AUDITORIUM. HALL LT PANEL-1,IP54@ Second Floor Include Thermostat with heaters.Incomer Incomer -1 (Grid Incoming Feeder) 1no.-TP+N 400 A-MCCB with Microprocessor LSI release and with indication lamps,MFMBus-bar 415V,TPN,50Hz,400 A Al BusbarOutgoing9 no.-40-100 A TPN MCCB with TMR and with indication lamps12 no.-32-100 A TPN MCCB with TMR and with indication lampsRest details as per SLD
705Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsSITC of Fire LT PANEL,IP54,25kA Include Thermostat with heaters.Incomer1 no.-TP+N 1000 A-MCCB with Microprocessor LSIG release and with indication lampsBus-bar 415V,TPN,50Hz,1000 A Al BusbarOutgoing2 nos.x 75 kW pump Soft starter comprising 250A 25 KA 3P MCCB with thermal magnetic field adjustable, Semiconductor fuses, Line Contactor,SPP,Timer with indication lamps1 nos.x 55 kW pump Soft starter comprising 250A 25 KA 3P MCCB with thermal magnetic field adjustable, Semiconductor fuses, Line Contactor, SPP,Timer with indication lamps1 no. -32A 10 KA DP MCB -For Battery Charger1 no.-32 A DP MCB2 no.-11 kW Y/Δ starter with 63 A 16kA TP MCCB with thermal magnetic field adjustable, AC 3 duty contactors,--- A O/L relay, other Accessories1 no.-TP 250 A-MCCB-25kA with TMR Protection with indication lamps
706Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsSITC of Plumbing LT PANEL,IP54Incomer1 no.-TP+N 63 A-MCB-10kA and with indication lampsBus-bar 415V,TPN,50Hz,100 A Al BusbarOutgoing2 no. -32A 10 KA TPN MCB 2 no.-32 A 10 KA SP MCB2 no.(W+S)-1.5HP DOL starter with 32 A 10kA TP MCB with thermal magnetic field adjustable, AC 3 duty contactors,--- A O/L relay, other Accessories2 no.(W+S)-2HP DOL starter with 32 A 10kA TP MCB with thermal magnetic field adjustable, AC 3 duty contactors,--- A O/L relay, other Accessories2 no.(W+S)-5HP DOL starter with 40-63 A 10kA TP MCB with thermal magnetic field adjustable, AC 3 duty contactors,--- A O/L relay, other Accessories2 no.(W+S)-7.5 HP S/D starter with 32 A 10kA TP MCB with thermal magnetic field adjustable, AC 3 duty contactors,--- A O/L relay, other Accessories
707SITC of 300+100(SVG)kVAR Hybrid APFC PANEL,IP54 Include Thermostat with heaters & fans.3 phase, 50 Hz.,Hybrid APFC Panel with derated power contactor of suitable rating forcapacitor switching Application for each step controlled bymicroprocessor based Hybrid controller APFC relay consisting of 2,3,5,5,10,10,15,20,30,50,100with APP type capacitor with 525 V and having minimumovercurrent capacity of 1.8 In, peak inrush current capacity 300 In andminimum life 150000 hours with detuned aluminium wound reactor of7/ 14% for each step, APFC Panel shall suitable rating ACB asincomer and each branch/step shall have separate isolation withMCCB of Suitable rating for protection, compliance to IEC 61439and power quality IEC 61921 standard.
708SITC of 150+100(SVG)kVAR Hybrid APFC PANEL,IP54 Include Thermostat with heaters & fans.3 phase, 50 Hz.,Hybrid APFC Panel with derated power contactor of suitable rating forcapacitor switching Application for each step controlled bymicroprocessor based Hybrid controller APFC relay consisting of 2,3,5,5,10,10,15,20,30,50,100with APP type capacitor with 525 V and having minimumovercurrent capacity of 1.8 In, peak inrush current capacity 300 In andminimum life 150000 hours with detuned aluminium wound reactor of7/ 14% for each step, APFC Panel shall suitable rating ACB asincomer and each branch/step shall have separate isolation withMCCB of Suitable rating for protection, compliance to IEC 61439and power quality IEC 61921 standard.
709Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsEV LT Panel-Upper Ground floor,IP 54,Include Thermostat with heaters.Incomer1 no.-TP+N 630 A-MCCB-25kA with Microprocessor LSI release and with indication lampsBus-bar 415V,TPN,50Hz,630 A Al BusbarOutgoing1 no. -32A 10 KA TPN MCCB -25kA with TMR Protection with indication lamps,Meter22 nos. -63A 10 KA TPN MCCB -25kA with TMR Protection with indication lamps,Meter1 no.-TPN 200A MCCB-25kA with TMR Protection with indication lamps,Meter
710Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsEV LT Panel-Lower Ground floor,IP 54,Include Thermostat with heaters.Incomer1 no.-TP+N 630 A-MCCB-36kA with Microprocessor LSI release and with indication lampsBus-bar 415V,TPN,50Hz,630 A Al BusbarOutgoing1 no. -32A 16 KA TPN MCCB -25kA with TMR Protection with indication lamps,Meter26 nos. -63A 16 KA TPN MCCB -25kA with TMR Protection with indication lamps,Meter1 no.-TPN 200A MCCB-25kA with TMR Protection with indication lamps,Meter
711Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsEV LT Panel-Basement floor 1,IP 54,Include Thermostat with heaters.Incomer1 no.-TP+N 630 A-MCCB-25kA with Microprocessor LSI release and with indication lampsBus-bar 415V,TPN,50Hz,630 A Al BusbarOutgoing1 no. -32A 25KA TPN MCCB ,Meter24 nos. -63A 25 KA TPN MCCB ,Meter1 no.-TPN 200A MCCB-25kA with TMR Protection with indication lamps,Meter
712Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsLift Pressurization LT Panel,IP 54,@ 5th Floor Include Thermostat with heaters.Incomer1 no.-TP+N 160 A-MCCB-25kA with TMR and with indication lampsBus-bar 415V,TPN,50Hz,160 A Al BusbarOutgoing1 no. -40A 10 KA FP MCB 7 nos. 7.5kW Y/Δ starter with 40 A 16kA TP MCCB with thermal magnetic field adjustable, AC 3 duty contactors,--- A O/L relay, other Accessories
713Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsLift LT Panel,IP 54,@ LG Floor Include Thermostat with heaters.Incomer1 no.-TP+N 320 A-MCCB-25kA with Microprocessor LSI release and with indication lampsBus-bar 415V,TPN,50Hz,320 A Al BusbarOutgoing12 no. -40-63A 10 KA FP MCB
714Supply,Installation, Testing & Commissioning of LT Panels comprising below points.1)-Panels shall be fabricated out of 16/14 swg CRCA sheet steel, with necessory structural supports in form of structural steel sections.2)-Floor mounted, IP-54 (Indoor),IP65(Outdoor)degree protection, Top or bottom cable entry/exit as per the case steel, 2mm frame & Door, 1.6 mm compartments & powder coating paint.3mm thick Gland plate.3)-The panel shall be compartmental, Form 3B type, with suitable size of bus bar and separate cable and busbar chambers. 4)-Proper gland size holes to be provided by the manufacturer with proper sticker and danger sign on all sides of panel.5)-The cable chambers shall be free from any live open connections and minimum cleareance to be provided for termination.6) Electrolytic Aluminum busbars grade E91E to IS 5082, 1 A/Sqmm,1100 V grade insulation, 50 kA for 1 sec, (IS-8623 for factory built assembly).7)- Earthing terminal at both end.8) Powder coating of approved color shade on both sides of provided iron work / MS / CRCA sheet steel work complete including anti-rust treatment - (7 Tank process) in an approved manner.9) Includes coordination & setting of all swtchgear with upstream & downstream switchgear.Refer SLD for more detailsUPS LT Panel,IP 54,@ SF Floor Include Thermostat with heaters.Incomer1 no.-TP+N 160 A-MCCB-25kA with TMR and with indication lampsBus-bar 415V,TPN,50Hz,160 A Al BusbarOutgoing2 no.-TP+N 125 A-MCCB-25kA with TMR2 no. -40-63A 10 KA FP MCB 4no. -32A 10 KA TPN MCB 14no. -32A 10 KA SP MCB
715Supplying & erecting three phase, 415V, street light control panel upto the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation as per specification SW-STCP.(External area)
716Supplying & erecting three phase, 415V, street light control panel upto the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation as per specification SW-STCP.
717Supplying, erecting & marking SP MCB 6A to 32A, C-series with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB
718Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB
719Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
720Supplying, erecting & marking TP MCB 6A to 32A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB
721Supplying, erecting & marking TP MCB 40A to 63A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB
722Supplying, erecting & marking FP MCB 6A to 32A, with rated short - circuitbreaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB
723Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
724Supplying, erecting and marking double pole isolator only switch version of miniature circuit breaker of 40A with required wiring connections and lugs etc. in provided distribution board.
725Supplying, erecting and marking 4 pole isolator only switch version of miniature circuitbreakers of 63A in provided distribution board.
726Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
727Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
728Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TPMCBs total 4 ways/12 Poles, with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no.SW-MCBDB.
729Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TPMCBs total 8 ways/24 poles, with door, 1.2mm thickness surface/flush mounted, IP43 Protection on provided iron/GI frame (vertical busbar type) as per specification no.SW-MCBDB.
730Supplying and erecting single pole and neutral distribution board (SPNDB), with 2ways for incoming and 8 ways (8 poles) for outgoing SP MCBs, with door, 1.2mmthickness surface/flush mounted, IP 43 Protection on provided iron/GI frame as perspecification no. SW-MCBDB
731Supplying and erecting single pole and neutral distribution board (SPNDB), with 2ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door,1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame as per specification no. SW-MCBDB
732Supplying and erecting single pole and neutral distribution board (SPNDB), with 2ways for incoming and 14 ways for outgoing SP MCBs, with door,1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame ,with all accessories.
733Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/32A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected onprovided angle iron/GI frame.
734Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 32 A, 3 pin plug & earth socket and 32A, 3 pin plug top with 32A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on providedangle iron/GI frame.
735Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB/TP MCB/FP MCB/RCCB/RCBO complete erected on provided angle iron/GI frame.
736Supplying and erecting blanking plate of suitable size on MCBDB.
737Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 poleMCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame(vertical busbar type) as per specification no. SW-SWR/MCBDB1
738Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 poleMCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame(vertical busbar type) as per specification no. SW-SWR/MCBDB1
739Providing & erecting 4 Pole MCCB microprocessor based with LSIG, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB
740Providing & erecting 4 Pole MCCB microprocessor based with LSIG, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no lineload bias in provided enclosure/panel as per specification no. SW-MCCB
741Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB.
742Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as perspecification no. SW-RCCB.
743Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with30/100/300 mA sensitivity with earth leakage trip indication complete as perspecification no. SW-RCCB.
744Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with30/100/300 mA sensitivity with earth leakage trip indication complete as perspecification no. SW-RCCB.
745Providing, erecting & commissioning 4 pole RCCB 63A, with added immunity toavoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specificationno. SW-RCCB.
746Supplying, erecting, testing & commisioning metal work in CRCA sheetincluding Iron work for supports with fabrication of boxes, panel boards, etc.including cutting, bending, drilling, welding, riveting, treated with anti-rusttreatment and painted with one coat of red lead paint and 2 coats of enamel paintor powder coating complete as per specification no. CP/SH/CR
747Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3 core 16 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
748Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3 core 50 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
749Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 25 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
750Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 35 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
751Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 50 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
752Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 70 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
753Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
754Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
755Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 150 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
756Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 185 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
757Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 240 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
758Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 300 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
759Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 3½ core 400 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
760Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
761Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL
762Supplying, erecting & terminating FR XLPE insulated, galvanised steel wirearmoured (round) cable 1100 V, 3 core 2.5 sq. mm. copper conductorcomplete erected with glands & lugs, on wall/ trusses/ pole or laid in providedtrench/ pipe as per specification no. CB-LT/CU
763Supplying, erecting & terminating FR XLPE insulated, galvanised steel wirearmoured (round) cable 1100 V, 3 core 4 sq. mm. copper conductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU
764Supplying, erecting & terminating FR XLPE insulated, galvanised steel wirearmoured (round) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
765Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
766Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
767Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
768Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU
769Supplying, erecting & terminating XLPE insulated, UN armoured (strip) cable 1100 V, 3 core 1.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
770Supplying, erecting & terminating XLPE insulated, UN armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
771Supplying, erecting & terminating XLPE insulated, UN armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
772Supplying, erecting & terminating XLPE insulated, UN armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
773Supplying, erecting & terminating XLPE insulated, UN armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
774Supplying & laying (including excavation) reinforced cement concrete pipe ofNP-2 class of 150 mm diameter in proper line, level and slope including providingand fixing collars in cement mortar 1:2 and curing etc. complete.
775Supplying & laying (including excavation) reinforced cement concrete pipe ofNP-2 class of 250 mm diameter in proper line, level and slope including providingand fixing collars in cement mortar 1:2 and curing etc. complete.
776Supplying and laying (including excavation of suitable width & depth up to 90cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, complete.
777Supplying & erecting watertight terminal box of 1.6 mm (16 gauge) CRCA sheetof size 200 x 150 x 150 mm. complete on pole as per specification No. CB-SB
778Supply and erection of 6m decorative hot Dip Galvanized step pole(Ø114.3), Single arm bracket of 1.0 Meter long made from 48.3 mm OD Pipe, min. 3 mm thick with cross support of 21.3 mm OD pipe, min.2.5 mm thick with cap pipe length of 1.0 Meter, with 4 Nos. bolts.The Bracket shall be capped with suitable decorative arrangement duly bolted/welded. With Outdoor Type Junction Box inside pole .Foundation set included.Similar to Klite KP-6217.
779SITC of 3 m Decorative pole with built in Light fitting of 60 W and 1 no. single arm length =900 mm.With Outdoor Type Junction Box inside pole.Foundation set included.Similar to KLITE 12048-300-LA-090-060 or Pasolite CAIN 1 POLE -P 10716.
780SITC of of 5 m Decorative pole with built in Light fitting of 3 x 20W and 3 nos. of single arm length.With Outdoor Type Junction Box inside pole.Foundation set included.Similar to Pasolite Fiesto Pole- P 10367 .
781Making M-20 grade reinforced cement concrete foundation by considering thesafe soil bearing capacity as 10 T/sq.m at 1.5m depth including supply of steel,concrete, excavation, fixing provided nut bolts with the help of template, dulyplastered as per design complete (for 3 to 5m octagonal/ conical GI pole).
782Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
783Providing & erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG GI sheet of 500 mm width & 100 mm height withrequired standard accessories.
784Providing & erecting hot dipped galvanised perforated type cable traymanufactured from 16 SWG GI sheet of 150 mm width & 75 mm heightcomplete with necessary coupler plates & hardware.
785Providing & erecting hot dipped galvanised perforated type cable traymanufactured from16SWG GI sheet of 200mmwidth&75mmheightcomplete with necessary coupler plates & hardware.
786Providing & erecting hot dipped galvanised perforated type cable traymanufactured from 16 SWG GI sheet of 300 mm width & 75 mm heightcomplete with necessary coupler plates & hardware.
787Providing & erecting hot dipped galvanised perforated type cable traymanufactured from16SWG GI sheet of 400mmwidth&75mmheightcomplete with necessary coupler plates & hardware.
788Providing & erecting hot dipped galvanised perforated type cable traymanufactured from 16 SWG GI sheet of 500 mm width & 75 mm heightcomplete with necessary coupler plates & hardware.
789Providing & erecting hot dipped galvanised cover suitable forladder/perforated type Cable tray manufactured from 18 SWG (1.2 mm thick)GI sheet of 150 mm width & 20 mm height complete with necessary hardware.
790Providing & erecting hot dipped galvanised cover suitable forladder/perforatedtypeCabletraymanufacturedfrom18SWGGIsheetof200mm width & 20 mm height complete with necessary hardware.
791Providing & erecting hot dipped galvanised cover suitable forladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 300mm width & 20 mm height complete with necessary hardware.
792Providing & erecting hot dipped galvanised cover suitable forladder/perforatedtypeCabletraymanufacturedfrom18SWGGIsheetof400 mm width & 20 mm height complete with necessary hardware.
793Providing & erecting hot dipped galvanised cover suitable forladder/perforated type Cable tray manufactured from 18 SWG GI sheet of 500mm width & 20 mm height complete with necessary hardware.
794Supplying and erecting iron work, sheet metal work consisting of MS sheets,various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc.for panel board or any other purpose with bending, cutting, drilling and weldingcomplete erected at the position with necessary materials duly painted withone coat of red oxide and two coats of enamel paint to match the switchgears oras per directions by the site engineer.
795Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or20 mm dia. G.I. Rod complete with all accessories of GI materials & recordingthe results as per specification no. EA-EP
796Supply, installing, and testing of maintenance free earthing comprising ofelectrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecularcopper bonded earthing rod of Length 3m along with Carbon basedenvironment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity (min. 125kg) complete, and recording theresults specification no. EA-MF
797Supply, installing, and testing of maintenance free earthing comprising ofelectrode of 25 mm diameter Low Carbon Steel with 250 micron molecularcopper bonded earthing rod of Length 3m along with Carbon basedenvironment friendly back fill ground enhancing compound required to fill up theexcavated earth with required quantity (min. 125kg) complete, and recording theresults .
798Supplying, installing and testing earthing with copper earth plate size 60 x 60 x0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l.cover with minimum 25 kg Carbon based environment friendly back fill groundehancing compound complete with all accesories of copper materials & recordingthe results as per specification no EA-EP/EF
799Supplying and erecting copper strip of required sizes used for earthing on walland/or any other purpose with necessary aluminium clamps fixed on wallpainted with bituminous paint with joints required as per specification no EA-EP.
800Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
801Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete.
802Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete.
803Supplying & erecting conventional spike type air termination suitable tocarry lightning stroke made up of heavy gauge (C class) 40 mm dia 1.2mtr copperpipe of standard length with 5 Nos. copper spikes fixed on copper ball of size100mm as air terminals duly threaded in copper pipe erected on providedfoundation in an approved manner as per spicification no. EA-LA
804Supply & Installation of Horizontal & vertical Aluminium Roof Conductor, of Diameter Ø8mm, Cross-section- 50 mm2, of Material- AlMgSi .
805Supply & Installation of Conductor holder for Parapet wall/Side wall of Material- stst, for rod size ø8- ø10 mm with accessories Screw and Gitty
806Supply & Installation of Al Expansion Pieces for equalizing temperature related length changes (every 20m for the mesh on the roof)
807Supply & Installation of Straight splicer with StSt hardwares suitable for Ø 8mm , to conduct two conductors, Round to Round, which are laid in line either on roof or on vertical walls
808Supply & Installation of TXL Connector with StSt hardwares suitable for Ø 8mm, to conduct two conductors, Round to Round, which are laid acrooss.Also to hold down conductors connected from roof conductors .
809Supply & Installation of Disconnecting clamp with StSt hardwares suitable for flat size upto 25 X 6 mm conductor & Round Conductor dia 8 mm .
810Supply & Installation of StSt Saddle / Holder for 25x6 mm to hold GI Strip .
811Supply & Installation of Lightning Flash Counter .
812Supply & Installation of TXL Connector with StSt hardwares, to connect two flat conductors which are laid acrooss with clamping range Flat size of 25X6 mm & Flat size of 25X6 mm .
813Supply & Installation of Universal Clamp with StSt hardwares to terminate the earth electrode & connect to grid conductor.
814Providing and back filling carbon based environment friendly back fill earthconductivity enhancing compound of 25 kg bag complete.
815Providing & Fixing of printed instruction chart for (with minimum 700 x1000 mm in size) treating persons suffering from electric shock, printed inEnglish & Marathi and duly laminated complete.
816Providing pair of duly tested rubber hand gloves as per IS :47705 suitablefor working upto 22 kV supply complete.
817Supplying and fixing standard first aid box with necessary antiseptic cream,medicine for use on wounds due burn, crepe bandage, gauge bandage,medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use,scissors, antiseptic solution, etc. (All above contents shall be of standard makes)
818Supplying and fixing PVC synthetic elastomer electrically insulating matwith class A insulation conforming to IS: 15652 – 2006 having 2 mm thicknessupto 3.3 kV
819Supplying and erecting under floor ,2mm Thick Hot Dip Galvanised junction box of size 150mm x 150mm x 50 to 95 mm (Adjustable Type)with flush finish having knock outs complete.
820Supplying, erecting, testing and commissioning of D.O.L starter suitable for 250V, single phase 50 Hz with overload element with necessary materials andconnected to supply upto 3 HP.
821Supplying, erecting, testing and commissioning of D.O.L starter suitable for 400V, 3 phase 50 Hz with no volt coil and overload element with necessary materialsand connected to supply above 3 HP to 7.5 HP.
822SITC of Linear Wall washer,RGBW Colour,40W DMX,IP-65, Compling to BIS standard IS 10322(Part 5/Sec):2012, and having CE certification against standard EN 61547: 2009, EN 60598-1:2015, and EN 61347- 2-13:2014.Mounting Structure : Additional wall mount yoke arrangements for fixing the lights. Rotation view : Inbuilt body rotating angle in degrees punched in the yoke/rear sides for uniform rotation angle to get the desired effect.Beam Angle 25°X25° or as per site requirement, Hot spot and light distribution : Optics Designed to minimize hot spots & fringing in color mixing applications.
823SITC of Xperia 150W DMX flood light, with all accessories.
824SITC of Extension cable 1Mtr length.
825SITC of outdoor IP boxes.
826SITC of Master Controller , 2 ports x 512 output which can control plus DMX pixels. It shall support off line control and play back content stored in the SD card up to 64 GB and also support at least 50 different scenes.It should be with digital touch screen display for changing modes, it supports master slave configuration to accommodate more DMX addresses( 8 x 512 pixels Slave Device) with outdoor enclosure. (DMX Controller UE 11 2X512)
827SITC of Splitter/ Booster. Isolated optical DMX splitter provides 8 outputs from a 1 input and Input voltage: AC 110 to 220 V, 50 Hz, Product features: Group 1 & group 8 DMX signal change. Improving/amplifying the input signals through longer distances.
828SITC of Address writer.
829SITC of XLR Cables
830Provide DMX Programming charges includes voltage stabiliser, SPD cost etc or Any other mounting accessories as per site
831Supplying, erecting, testing and commissioning of 10kW, 3 x 3.3 KW ACElectric Vehicle charger (suitable for 2/3/4 wheeler) having minimumIK08/IP 54 Protection suitable for three phase, 415V AC, 50Hz incoming and 3 nos. of outgoing as per IEC 60309 industrial sockets having capacity ofoutput current of 16A 240VAC at each socket with 3.5\\"TFT touch screen forhuman interface & LED Light for status indication and metering for measurementof consumed energy having metering accuracy +/-1%, one hour battery backupfor communication, emergency push stop button,with user interface by mobile application/QR Code/RFID Card and having short circuit, over & undervoltage, overload,over temperature, earth leakage protection and enclosure madeof minimum 1.5mm duly RAL7035 Coated M.S, Erected on iron/GI frame onprovided cement concrete foundation complete with one year on site warranty,Confirming to IS 17017 Series as per specification no. ESD-EVC.
832Supply, Installation, Testing and Commissioning 7.2 kW AC Electric Vehiclecharger (suitable for 4 wheeler) having minimum IK08 & IP54 protectionsuitable for single phase, 230V AC, 50Hz, incoming and 1 nos. of outgoinghaving capacity of output current of 32A at 230V with Type two connectoras per IEC 62196-2 , Interlocking arrangement & minimum 5 meter chargingcable length, 3.5\\" TFT screen for human interface & LED light for statusindication and metering for measurement of consumed energy having meteringaccuracy +/-1%, one hour battery backup for server communication,emergencypush stop button,with user interface by mobile application/QR Code/RFIDCard/Password Login and having short circuit, over & under voltage, overload,earth leakage ,Over temperature, surge protection and enclosure made ofminimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame onprovided cement concrete foundation complete with one year on site warranty,conforming to IS 17017 Series as per specification No. ESD-EVC.
833Supplying, erecting, testing and commissioning of 60 kW DC ElectricVehicle Charger (suitable for 4 wheeler) having minimum IK08 & IP 54Protection suitable for three phase, 415V AC, 50Hz incoming supply and 2 nos of30kW outgoing charger interface CCS2 with 200-1000VDC supply,interlocking arrangement with minimum 5 meter charging cable Length, 7\\" LCDTouch Screen for human interface & LED Light for status indication andmetering for measurement of consumed energy having metering accuracy +/-1%,One hour battery backup for communication, emergency push stop button. Userinterface by mobile application/QR Code/RFID Card/Password Login withpayment options and having short circuit, over & under voltage, input phasereversal, surge protection, earth leakage protection and enclosure made ofminimum 1.5mm duly RAL7035 coated M.S, erected on iron/GI frame onprovided cement concrete foundation complete with one year on site warranty,conforming to IS 17017 Series as per specification No. ESD-EVC.
834SITC of CE Certified 200W LED PARCAN Light with latest RDM technology for user friendly operation with below specifications: • Light Source : Single COB LED Source• Color Temperature : 3200K with CRI & TLCI Value > 90• Power cable: 3 core 1 sq. mm. copper PVC insulated • Channels: 1/2 DMX-512 Channel Modes• Beam angle: 9°/15°/20°/25°/30° Manually Selectable • Control mode: RDM, DMX512 & Manual, Master/Slave, Auto run• Fully RDM Compliant in DMX Mode for the Lighting Console mentioned in this project.• LUX @ 2m: > 41,000 @ 9° Beam Angle• Dimming: 0 - 100% Electronic Dimming• Function: Strobe, Dimming• Housing : Spun Aluminium Housing with black epoxy polyster powder coated finish.• Accessory slot for Gel frame and Barndoor should be available or else fixture will be rejected.• Power and DMX: Loop in and loop out compulsary• DMX in & Out Through : 5 Pin XLR connectors• Certification: CE / BIS
835SITC of CE Certified 400W LED Blinder Effect Light with latest RDM technology for user friendly operation with below specifications: • Light Source : Quad LED COB Source• Power Factor : >0.95 @ 230V AC 50Hz• Color Temerature : 3200K, CRI & TLCI Value > 95• Power cable: 3 core 1 sq. mm. copper PVC insulated • Channels: 4/8 DMX-512 Channel Modes• Beam Angle : 40°• Control mode: RDM, DMX512 & Manual, Master/Slave, Auto run• Fully RDM Compliant in DMX Mode for the Lighting Console mentioned in this project.• Lux output at 2 Mtr : > 8,500 Lux @ 40°• Dimming: 0 - 100% Electronic Dimming• Power and DMX: Loop in and loop out compulsary• DMX in & Out Through : 5 Pin XLR connectors• Certification: CE / BIS
836SITC of CE Certified 54 x 3W LED PAR Light with latest RDM technology for user friendly operation with below specifications: • Base Color RGBW Color Mixing• LED Configuration : Multiple Nos Individual RGBW LED Configuartion• Power cable: 3 core 1 sq. mm. copper PVC insulated • Channels: 8 DMX-512 • Beam angle: 15° • Control mode: RDM, DMX512 & Manual, Master/Slave, Auto run, Sound Active• Fully RDM Compliant in DMX Mode for the Lighting Console mentioned in this project.• LUX @ 2m: >10,500 @ 15° Beam Angle• Dimming: 0 - 100% Electronic Dimming• Function: strobe, dimming, sound active and Master slave.• Housing: Die Casted Aluminium or Metal Housing with black epoxy polyster powder coated finish.• Power and DMX: Loop in and loop out compulsary • DMX in & Out Through : 5 Pin XLR connectors • Certification: CE / BIS
837SITC of CE Certified LED PAR Light with latest RDM technology for user friendly operation with below specifications: • Base Color 3200K Color Mixing• Color Temperature : 3200K, CRI & TLCI Value > 90• LED Configuration : Multiple Nos Individual 3200K LED Configuartion• Power cable: 3 core 1 sq. mm. copper PVC insulated • Channels: 1 DMX-512 • Beam angle: 15° • Control mode: RDM, DMX512 & Manual• Fully RDM Compliant in DMX Mode for the Lighting Console mentioned in this project.• LUX @ 2m: >7,500 @ 15° Beam Angle• Dimming: 0 - 100% Electronic smooth Dimming• Function: strobe, dimming, sound active and Master slave.• Housing: Die Casted Aluminium or Metal Housing with black epoxy polyster powder coated finish. • Power and DMX: Loop in and loop out compulsary • DMX in & Out Through : 5 Pin XLR connectors • Certification: CE / BIS
838SITC of CE Certified 300W LED Profile Spot Light with latest RDM technology for user friendly operation with below specifications: • Light Source : Single LED COB Source• Power Factor : >0.95 @ 230V AC 50Hz• Color Temerature : 3200K, CRI & TLCI Value > 95• Power cable: 3 core 1 sq. mm. copper PVC insulated • Channels: 1/2/3 DMX-512 Channel Modes• Beam Angle : 19° or 15°• Control mode: RDM, DMX512 & Manual, Master/Slave, Auto run• Fully RDM Compliant in DMX Mode for the Lighting Console mentioned in this project.• Lux output at 2 Mtr : > 27,500 Lux @ 19° or 15°• Dimming: 0 - 100% Electronic Dimming • 4 Beam shaping shutters• Accessory slot for Gobo and gobo holder, Iris & Color Frame should be available or else fixture will be rejected.• Housing: Metal Housing with black epoxy polyster powder coated finish or PVC Body with matt black finish• Power and DMX: Loop in and loop out compulsary • DMX in & Out Through : 5 Pin XLR connectors • Certification: CE / BIS
839SITC of 200W LED PC Spot Light with latest RDM technology for user friendly operation with below specifications:• Light Source : Single LED COB Source• Color Temerature : 3200K, CRI & TLCI Value > 95• Power cable: 3 core 1 sq. mm. copper PVC insulated• Channels: 2/3/6 DMX-512 Channel Modes• Beam Angle : 20° or 48° Motorised zoom• Control mode: RDM, DMX512 & Manual, Master/Slave, Auto run• Fully RDM Compliant in DMX Mode for the Lighting Console mentioned in this project.• Lux output at 2 Mtr : > 9,400 Lux @ 20° & > 1,800 Lux @ 48°• Dimming: 0-100% Electronic smooth dimming operation. • Power and DMX: Loop in and loop out compulsary• DMX in & Out Through : 5 Pin XLR connectors
840SITC of Smooth Dimming Fresnel spot light with minimum following Technical specifications• Light Source : Single LED COB Source• Color Temerature : 3200K• CRI & TLCI : > 95 • Beam Angle : 9° - 52° manual Zoom• Focusing mechanism of lights should be SS/Brass lead screw type for step less zooming. Sliding type focusing mechanism shall not be acceptable. • Fresnel Lens Dia should not lesser than 200mm• Zooming function of Fresnel should be Manually operated. • Dimming: 0 - 100% Electronic smooth Dimming• Lux output at 2 Mtr : > 12,200 Lux @ 9° &> 1,800 Lux @ 52° • Accessory slot for Gel frame and Barndoor should be available or else fixture will be rejected.• Control Protocol : DMX & Manual• Fully RDM Compliant in DMX Mode• Manual Control via Tactile Switch for user control of fixture.
841SITC of CE Certified 300W LED HYBRID MOVING (Beam, Spot & Wash Effect) Light with RDM protocol and Hi grade plastic body black color with following specifications - • LED : 300W Cool White LED.• Beam Angle : 3°~4°, Zoom Angle : 8°~15°• Power Consumption : 400W ± 10%• Light Out put : >60,000 Lux at 2 Mtrs• Color Wheel : Minimum 8 Colors and open or More• Fixed Gobo Wheel : Minimum 9 Fixed Gobos or More • Rotating Gobo wheel : Minimum 7 Rotating Gobos or More • User Interface : 4 Nos High Precision Membrane type selector switch with LCD Display • Fully RDM Compliant when in DMX mode• Dimming : 0 to 100% 16 Bit Linear Dimming• DMX data IN / OUT: 5 pin locking XLR • Cooling system with low noise fan for forced ventilation • 3 Mtr 3 core 1 mm² FRLS & ISI mark cable with 3pin IEC Male Plug with proper earthing • 3 mtr DMX loop cable with cable mount 5 pin locking XLR • CE Certificate should be enclosed to ensure the required quality and safety of the products.
842SITC of Die cast Aluminium C - Clamp with safety chain duly epoxy polyester powder coated in black matt texture finish and safe working load of 100kg with below specifications.• Lock - MS threaded Galvanized lock key, • Plastic Glass filled nylon moulded M6 key. • Receptacle - 28mm standard TV spigot. • Safety - MS Galvanized chain with pin. • Finish - Pretreated and black epoxy polyester powder coated. • Self-weight - 0.54Kg
843SITC of Safety bond with lock clip 1.5 Mtr Long made with twisted pair of GI wire rope, 2mm or 3mm Thickness with sleeve to be fixed around the grid to avoid fall of the material in case if the \\"C\\" clamp is not locked properly. SWL 150Kgs.
844SITC of 79mm Round Identification name plate duly epoxy polyester powder coated in matt texture finish.
845SITC of CE Certified Motorised Stage Light bar Suitable Length 13 Mtrs as per site requiremnents, Suitable Capacity 3 Phase AC Motor with DC Brake & Gear box with black epoxy polyester powder coated with following specifications - • 40NB, 48mm OD dual barrel dual construction arrangement with MS Flat in every 2 m and with 40x75 Cable trunking with lid.• MS fabricated cable retractor made up of CRCA MS Sheet 1300mm each length with hinge rod • Specially designed compact 80:1 Worm reduction gear box, B5 Flange. • Double Cam type Upper and lower limit controller 5mm, 6x19 GI wire rope preformed for lifting the Light bar• Pile winding type winch with MS circular Plates for rope winding • Safe Working Load 180 kg
846SITC of CE Certified Motorised FOH Light bar Suitable Length 14 Mtrs as per site requiremnents, Suitable Capacity 3 Phase AC Motor with DC Brake & Gear box with black epoxy polyester powder coated with following specifications - • 40NB, 48mm OD dual barrel dual construction arrangement with MS Flat in every 2 m and with 40x75 Cable trunking with lid.• MS fabricated cable retractor made up of CRCA MS Sheet 1300mm each length with hinge rod • Specially designed compact 80:1 Worm reduction gear box, B5 Flange. • Double Cam type Upper and lower limit controller 5mm, 6x19 GI wire rope preformed for lifting the Light bar• Pile winding type winch with MS circular Plates for rope winding • Safe Working Load 180 kg
847SITC of MS Side Lighting Ladder of suitable length and Width (Min 2400 mm Height & 600 mm Width)• Made using 40NB, 48MM OD, 2mm thickness MS Pipe • Suitable suspender and clamps made with MS Angle of size 40x40x5 mm thick or higher size• Inverted 4-Wheeler Trolley with Flexi Adaptor Clamp, • Heavy duty Ladder Track to be laid throughout the depth of the stage.• 360° Rotatable and can move in unidirectional• All the materials under gone through 7 tank process with various chemical treatment to keep them rust free with and duly epoxy polyester powder coated in black matt texture finish.
848SITC of MS Fabricated 4 way 10A, 250V A.C, IEC, Lighting Junction box made up of 22SWG CRCA for LED lighting fixtures with Pipe clamp arrangement for fixing on pipe grid or Raul plug arrangement for wall/floor fixing, duly black epoxy polyester powder coated texture finish.
849SITC of MS Fabricated 2 way 10A, 250V A.C, IEC, Junction box made up of 22SWG CRCA with rocker switch to power up splitter and console with Pipe clamp on pipe grid arrangement for fixing or Raul plug arrangement for wall/floor fixing, duly black epoxy polyester powder coated texture finish.
850SITC of MS Fabricated 5 pin DMX Signal IN Junction box fitted with 5 pin DMX Male socket, junction box made up of 22SWG CRCA, with Pipe clamp on pipe grid arrangement for fixing or Raul plug arrangement for wall/floor fixing, black epoxy polyester powder coated, duly black epoxy polyester powder coated texture finish.
851SITC of MS Fabricated 5 pin DMX Signal OUT Junction box fitted with 5 pin DMX female socket, junction box made up of 22SWG CRCA, with Pipe clamp on pipe grid arrangement for fixing or Raul plug arrangement for wall/floor fixing, black epoxy polyester powder coated, duly black epoxy polyester powder coated texture finish.
852SITC of Fabricated 5 pin DMX Signal loop Junction box fitted with 5 pin DMX Male & Female socket with 0.3 Mtr DMX Loop cable fitted with 5 pin DMX cable mount plug, junction box made up of 22SWG CRCA, with Pipe clamp on pipe grid arrangement for fixing or Raul plug arrangement for wall/floor fixing, black epoxy polyester powder coated, duly black epoxy polyester powder coated texture finish.
853SITC of Well designed Direct Lighting Distribution Board made up of CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly powder coated with Matt texture finish consists of R, Y, B Indicator lamp, SP Mcb's and for the junction boxes fixed on the top of the light bar including wiring and busbar connection with proper earthing and Hingable door with magnetic door lock complete.
854SITC of Auxiliary marshalling box for power and signal cable termination in grid level and in Motorised Light bar• CE Marked FC/PG cable entry gland required Nos as per cable entry.• MS channel arranging to fix terminal connector, required nos with separation plate and each end is completed with adding end plate with end cap. • Grey terminal connector with each line having P, N, E Indication for each line incoming and out going cable connectors. • Box door must be made with Hingeable door with screw lock. • Made up of 20SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly epoxy polyester powder coated with Matt black texture finish.
855SITC of Motor Cable Termination box for power cable termination at grid level.• CE certified FC/PG 11 & 13.5 cable entry gland required Nos as per cable entry.• MS channel arranging to fix grey terminal connector, required nos with separation plate and each end is completed with adding end plate with end cap. • Grey terminal connector with each line having L1, L2, L3, E, 6 , 2 , 4 Indication for each line incoming and outgoing cable connectors (L1, L2, L3, E for Power supply & 6 , 2 , 4 for Limit Switch connection) • Box door must be made with Hingeable door with screw lock. • Grid mount fixing arrangement for fixing on grid or Anchor fastener for wall/floor fixing • MS Boxe made up of 20SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly epoxy polyester powder coated with Matt black texture finish.
856SITC of MS Fabricated Combined Motor Control Center panel cum Remote Control panel for Light bar system made up of 14SWG / 16SWG / 18 SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly epoxy polyester powder coated with Matt seaman’s grey texture finish with following specifications. • Main Contactor of 9A 240V 4 pole contactor with 04 -06A Over Load relay for safety • 24V 4 pole Low Voltage Contactors • 240V / 24 V Step-down transformer for Low voltage Contactors • All the FRLS PVC ISI Marking cables inside the panel routed through PVC gray color cable trough. • Red Color Mushroom head push button for emergency stop • Yellow color reset push button • Master sector actuator switch with 3 Position UP, DOWN & OFF • Spring return selector switch for each hoist with UP & DOWN indication. • All the cables inside the panel routed through PVC gray color cable trough. • Panel Including wiring with proper earthing.
857SITC of RDM Compatible DMX Splitter unit with Minimum following specifications.● 1 Nos 5 Pin DMX In socket and 8 Nos 5 Pin DMX Out socket● In and out signal Optically Isolated● LED Indicator for check the signal flow in output.●Suitable for standard 19” cabinet● Duly black epoxy polyester powder coated texture finish.
858SITC of RDM Compatible Digital Lighting console with Minimum following specifications FLX S48 .● 2048 Channel, 4 Universe ● 2 nos of DMX 5 Pin output.● No. Of Direct Fixture Control : Atleast 192 or more● No. Of Multifunction Faders : Atleast 48 ● Atleast 4 Encoder Wheels ● 7inch LED Display for Navigation● Should support ART-NET Port ● Fully RDM Compiant in DMX Mode● External monitor support ● Display Outputs : 1x HDMI ● Ethernet : 1x RJ45
859SITC of 5 pin XLR male / female connectors of made up of Extra high temperature resistant insulator material, Larger solder contacts for easier termination.
860SITC of 5 Pin XLR Termination plug made up of extra high temperature resistant insulator material, Larger solder contacts for easier termination with 120 Ohm resister with 0.25Watt for signal termination.
861SITC of PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 4cx 4 sq mm.
862SITC of PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 7cx1.5 sq mm.
863SITC of DMX Signal 2 OR 4 core + Ground shielding Cable with CE mark for the Signal network.
864SITC of MS perforated tray of Size 40 x 75 x 40mm & 1.6 mm Thickness undergone through 7 tank process with various chemical treatment to keep them rust free, duly epoxy polyester powder coated with Matt black texture finish along with clamping arrangement.
865SITC of MS perforated tray of Size 40 x 150 x 40mm & 1.6 mm Thickness undergone through 7 tank process with various chemical treatment to keep them rust free, duly epoxy polyester powder coated with Matt black texture finish along with clamping arrangement.
866SITC of Internal earthing copper bare conductor of size 14 SWG for power network related to work coming under our scope.
867SITC of hardware’s such as clamps, connectors, glands, lugs, ferrules, welding rods and miscellaneous items required during installation work.
868SITC of CE Certified Motorised Utility bar Suitable Length 12 Mtrs as per site requiremnents, Suitable Capacity 3 Phase AC Motor with DC Brake & Gear box with black epoxy polyester powder coated with following specifications - • 40NB, 48mm OD dual barrel dual construction arrangement with MS Flat in every 2 m and with 40x75 Cable trunking with lid.• Specially designed compact 80:1 Worm reduction gear box, B5 Flange. • Double Cam type Upper and lower limit controller 5mm, 6x19 GI wire rope preformed for lifting the Light bar• Pile winding type winch with MS circular Plates for rope winding • Safe Working Load 180 kg
869SITC of 1000W CE Certified halogen Fresnel spot light providing illumination of 28000 lix at 2 mt in spot at 10° beam angle while 4600 lix at 2 mt when operated in flood at 48° beam angle , dimension as 290 x 405 x 290mm, 150mm aid German lens, weight of 4.6Kg, Gx9.5 base lamp socket,power cord with 16amps 3 pin CE plug and normal yoke but without lamp and accessories. Lamp - 1000W 230V single ended lamp Power supply - 230-240V AC,Lamp Socket - Gx9.5Power cable - 3 core 1.5 sq. mm. copper PVC insulated,Housing - Light weight, rugged and reliable both indoor and outdoor,Robust per-treated fabricated housing with die cast component and epoxy polyester powder coated,Distribution - Delivers smooth uniform field across the entire spread from spot to flood focusing,Switching options - Local control and Digital DMX control through Dimmer,Dimming option - Digital DMX control through Dimmer,Reflector - Spherical high reflective aluminum anodized,Yoke - Fabricated using MS flat-accepts mounting on 16mm spud,Focus - controlled by front & rear thermoplastic knob.
870SITC of 1000W spun aluminum PARCAN made out of spun aluminum 16 SWG in 2 piece cylindrical construction with punched slot on Par can housing for natural ventilation and floating ceramic GX16d base lamp socket,copper flexible PVC insulated power cable with 3 pin CPL plug, Yoke made of MS flat 25 X 3mm with 13mm free mounting hole to fit the adapter, spigot with 28mm and filter frame but without lamp. \\"Lamp: 1000W 240V PAR-64,Lamp Socket: Ceramic type GX 16D.Power Cable: 3 core,1 Squirm copper PVC insulated flexible cable with 10 amps double pole toggle switch,Housing: Aluminum sheet cylindrical construction with black epoxy polyester powder coated\\",\\"Switching options: Local control and Digital DMX control through Dimmer,Dimming option: Digital DMX control through Dimmer,Yoke: Fabricated using MS flat-accepts mounting on 28mm spud Focus: Sealed beam angle,Accessories: Filter frame.
871SITC of 1000W 230V single ended halogen lamp CP24 / CP70 Base Gx9.5.
872SITC of 1000W 230V Par-64 narrow / medium / wide lamps with base Gx16d for 1kW Halogen parcans.
873SITC of Fixed 3/4 Side FOH ladder made using 40NB dual barrel arrangement along with movable arrangement in between undergone 7Tank chemical treatement to keep them rust free and powder coated and provided with cable trays and adjustable bar arrangements. Size 2.4m x 0.6m.
874SITC of 1500W Haze machine, Warm up time 2 Minutes with following specifications - • Power Consumption : Max 1500W• Pre Heating Time 2 Minutes• Oil Tank capacity : 2 ltr• Control Mode : Manual / DMX / remote Control• DMX Channel : 2 Channel• Housing: Metal Housing with black epoxy polyster powder coated finish or PVC Body with matt black finish• Power and DMX: Loop in and loop out compulsary• DMX in & Out Through : 5 Pin XLR connectors
875SITC of 1500W Fog machine, Warm up time 5 Minutes with following specifications - • Power Consumption : Max 1500W• Pre Heating Time 5 Minutes• Oil Tank capacity : 5 ltr• Control Mode : Manual / DMX / remote Control• DMX Channel : 2 Channel• Housing: Metal Housing with black epoxy polyster powder coated finish.• Power and DMX: Loop in and loop out compulsary• DMX in & Out Through : 5 Pin XLR connectors
876SITC of 150W LED RGBW Cyclorama Wash Light with RDM protocol and Laser cut aluminium body duly epoxy polyester powder coated in black matt texture finish with following specifications -• LED : 480 RGBW LED (120R + 120G + 120B+ 120W) Nichia or Lumiled Make LED • Beam Angle : 96°• Detachable Assymmetric reflector with 64°, 62° for uniform wash. • Light Out put : 1200 Lux at 1 Mtrs without assymmetric reflector. • User Interface : 4 Nos High Precision Tactile type selector switch with Seven Segment Display • Fully RDM Compliant when in DMX mode • Dimming : 0 to 100% 8 Bit Linear Dimming • DMX data IN / OUT: 5 pin locking XLR • Natural Cooling System. No fan, No noise.• 2.5 m Power In + 0.5 m Power out or 3 Mtr 3 core 1 mm² FRLS & ISI mark cable with 3pin IEC Male Plug • 3 mtr DMX loop cable with cable mount 5 pin locking XLR
877SITC of 4 Way Grid mount dimmer pack with 16A CE output socket, 5 pin XLR socket for DMX Control.• Maximum 10A per channel, total 30A. • DMX 512 signal. • 2 sets of signal input/output, 3 pin XLR connector and RJ11 phone jack. • LED display. • Automatic warm up function protects loads and extend the life of fixtures. • Auto frequency tracking. • ‘C3’ dimming curve. • DMX start channel address setting. • Channel dimming test. • 256 steps dimming resolution.• Equipped with clamp for truss hanging or desktop operation.SPECIFICATION• Power : AC 100-120V, AC 200-240V, 45-63Hz, 2 input • Output : Max. 10A per channel, total 30A • Signal input / output : DMX 512 / 1990 • Signal connector : XLR 3pin, 6P4C, RJ12 phone jack. • Installation : Truss hanging or desktop operation. • Fuse : 10A • Weight : 3.2kg
878SITC of High quality power junction box 1 way made up of MS Sheet metal fabricated housing black powder coated, fibre glands of suitable size fitted with 32A CEE connector.
879SITC of PVC Copper unarmoured flexible FRLS insulated multicore cable 1100V grade confirming to IS694 size 3cx4 sq mm.
880SITC of Motorised Main Curtain track system 16.5 Mtrs long, center parting with overlap of 0.9mtr arrangement undergone through various chemical treatment to keep them rust free and duly epoxy polyester powder coated in black matt texture finish with Below Specifications: • Heavy duty curtain track duly epoxy polyester powder coated in black matt texture finish. • GI wire ropes with steel core at center. • Curtain holding trollies placed uniformly at specific interval of 200mm /250 mm throughout the track. • Diverter pulley • MS yellow passivized Routing pulleys with ball bearing for smoother noiseless movement 165mm for outer diameter, 145mm diameter at groove base with 12mm pulley thickness. • All the materials under gone through 7 tank process with various chemical treatment to keep them rust free with and duly epoxy polyester powder coated in black matt texture finish. (For Main, Mid & Rear Curtain)
881SITC of Motor Cable Termination box for power cable termination at grid level.• CE certified FC/PG 11 & 13.5 cable entry gland required Nos as per cable entry.• MS channel arranging to fix grey terminal connector, required nos with separation plate and each end is completed with adding end plate with end cap. • Grey terminal connector with each line having L1, L2, L3, E, 6 , 2 , 4 Indication for each line incoming and outgoing cable connectors (L1, L2, L3, E for Power supply & 6 , 2 , 4 for Limit Switch connection)• Box door must be made with Hingeable door with screw lock. • Grid mount fixing arrangement for fixing on grid or Anchor fastener for wall/floor fixing• MS Boxe made up of 20SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly epoxy polyester powder coated with Matt black texture finish.
882SITC of MS Fabricated Combined Motor Control Center panel cum Remote Control panel for Curtain system made up of 14SWG / 16SWG / 18 SWG CRCA sheet undergone through 7 tank process with various chemical treatment to keep them rust free, duly epoxy polyester powder coated with Matt seaman’s grey texture finish with following specifications.• 16A TP or TPN Incomer. • Main Contactor of 9A 240V 4 pole contactor with 04 -06A Over Load relay for safety • 24V 4 pole Low Voltage Contactors • 240V / 24 V Step-down transformer for Low voltage Contactors • All the FRLS PVC ISI Marking cables inside the panel routed through PVC gray color cable trough. • Red Color Mushroom head push button for emergency stop • Yellow color reset push button • Master sector actuator switch with 3 Position UP, DOWN & OFF • Spring return selector switch for each hoist with UP & DOWN indication. • All the cables inside the panel routed through PVC gray color cable trough. • Panel Including wiring with proper earthing.
883Audotorium Step Lighting :- SITC of LED Step Light, 1300MM , Blue Colour with Down light with Required Power supply, with number plate , complete with complete wiring in conduit as per site conditions.
884Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 3 x 8 universal extensions compliant to IEC 61000, EN 60950, CISPR 22, IS:9000 part 2/section 4 having LAN/WAN Port, USB port, RS232 port as perspecification complete as per specification no. WG-TANote :- 1) Add Rs. 37421.00 for additional 16 extension card for digital (hybrid) type EPABX.2) Add Rs. 19662.00 for additional 8 extension card for digital (hybrid) type EPABX.
885Supplying, erecting & commissioning 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TA.
886Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TA.
887Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TA.
888Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete.
889Supplying, erecting & terminating 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW.
890Supplying, erecting & terminating 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW.
891Supplying, erecting & terminating 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit as per specification no. WG-TW.
892Supplying and installing a PBT loose tube HDPE sheathed armoured single mode optical fiber cable with 12 fiber, core dia 9/125μm (OS1/OS2) 10 GBPS speed compliant to IEC 60793/IEC 60794 standards in provided pipe/trench complete.
893Supplying and erecting modular type telephone socket one gang with safety shutter on provided plate and box with wiring connections complete.
894Supplying, erecting, testing & commissioning Mixer Amplifier 250W RMS Power with Built-in Digital Player, MP3 Player with USB/ SD/ MMC Card Reader, Bluetooth with remote and having min 6 Mic & 2 Aux Inputs with Box Speaker/Driver Unit selector switch. Frequency response 50-15,000Hz ±3dB. The unit shall have Preamplifier and Line Output for connecting to a BoosterAmplifier and for recording the programme with Resettable circuit breaker for protection against overload and short circuit. The unit shall have speaker output range of 4Ω, 8Ω/(Low Impedence) and 70V & 100V/(High Impedence) & It caninstant transfer to DC power if AC power fails. Signal to noise ratio between 60dB to 65dB complete as per specification no. PA-MA.
895Supplying, erecting, testing & commissioning Mixer Amplifier 500W RMS Power with Built-in Digital Player with remote and having 7 Mic & 3 Aux Inputs with Box Speaker/Driver Unit selector switch to each zone , stereo/mono switch, frequency response 50-15000Hz, output regulation <2dB, serprate control for USB level. The unit shall have Preamplifier and Line Output for connecting to a Booster Amplifier and for recording the programme with Resettable circuit breaker for protection against overload and short circuit. The unit shall have speaker output range of 2Ω, 4Ω/(Low Impedence) and 70V & 100V/(High Impedence) & It can instant transfer to DC power(36V) if AC power fails. Signalto noise ratio between 60dB to 80dB. Complete as per specification no. PA-MA.
896Supplying,installing, testing & commissioning 2-Way flush mount Ceiling Speakers with input power 20W RMS power, with power taps on 20/10/5W,100V & 70V line, frequency response 90-18000Hz, stylish metal mesh grill and plastic frame, operates on 100V line for excellent reproduction of both speech and music, wide frequency response and adjustable tweeter complete as perspecification no. PA-FMCS.
897Supplying, installing, testing & commissioning 2-Way flush mount Ceiling Speakers with input power 30W RMS power, with power taps on 30/15/7.5W,100V & 70V line, frequency response 90-18000Hz, stylish metal mesh grill and plastic frame, operates on 100V line for excellent reproduction of both speech and music, wide frequency response and adjustable tweeter complete as per specification no. PA-FMCS.
898Supplying, installing, testing and commissioning 15W PA Column Speakers with 15W RMS power in aluminium extruded cabinet, Moulded Plastci Covers & Metal mesh grill, frequency response 150-15,000Hz, operates on 100V line with power taps of 15/10/5/2.5W in black or white color,With Mounting clamps & Necessary hardware, as per decesion by Engineer-in charge complete as per specification no. PA-CS.
899Supplying, installing, testing and commissioning 30W PA Column Speakers with 30W RMS power in aluminium extruded cabinet, Moulded Plastic Covers & Metal mesh grill, 100V transformer with rotary switch for power tap selection, frequency response 150-10,000Hz, with power taps of 30/20/10/5 W in black or white color as per the decision of Engineer-in charge, complete with mounting clamps & necessary hardware complete as per specification no. PA-CS.
900Supplying & erecting 2-Way Compact PA Wall Speaker of 16W High Fidelity sound with rated voltage 100V, power taps of 16W, 8W, 4W, Power Taps can be selected through an easily accessible rotary switch, Low impedence 8Ω, frequency response 85-20000Hz. Weather Resistant speaker with movable mounting bracket with required screws complete as per specification no. PA-CPAWS.
901Supplying & erecting 2-Way Compact PA Wall Speaker of 32W High Fidelity sound with rated voltage 100V, power taps of 32W, 16W, 8W, Power Taps can be selected through an easily accessible rotary switch Low impedence 8Ω, frequency response 80-20000Hz. Weather Resistant speaker with movable mounting bracket with required screws, complete as per specification no. PA-CPAWS.
902Supplying, erecting, testing and commissioning PA Mixer 10 channel with MP3 Player with USB/SD card reader and Bluetooth facility, 48V Phantom Supply on 4 Channels, 8 MIC/LINE Balanced Mono input channels, 1 Stereo balanced input channel in 2 selectable sensitivities of -10dBu & +4dBu, Frequency Responce : 25Hz - 20kHz,Impedance : 600Ω,Signal to noise ratio : >70dB,Operates on 240V 50Hz AC supply, built-in Digital Effects processor with Delay, Repeat and Level controls. Each input channel has a GAIN control, 3 band active Equalizer controls, a Pre-fader AUX1 control, a Post-fader AUX2 /EFX control & a PAN control, STEREO channel has a GAIN control, 2 band active Equalizer controls, AUX1 Pre fader control, AUX2/EFX Post fader control and a BALANCE control with Channel ON/OFF switch provided on each individual channel, complete as per specification no. PA-MXR.
903Supplying, erecting, testing and commissioning of multistrand annealed bare copper conductor, transparent PVC insulated 2C x 1.5 sqmm speaker wire in provided trunking/conduit etc.complete as per specification no. PA-TSPWR
904Supplying, Installing, testing and commissioning of Supercardioid professional Wired Dynamic microphone with noiseless magnetic read switch, frequency Response : 50-18,000Hz, Sensitivity : 2.5mV/Pa, Impedance : 300Ω, with quick detachable holder with 3-pin professional XLR connector & 10m twin core shielded low noise cable on provided stand complete as per specification no.PA-WDM.
905Supplying & erecting Microphone floor stand with Height 920-1500 mm, Base Dia- 230 mm, min. weight 3.6 kg with superior quality of chrome plating/ powder coating (resistant to rust & corrosion) having sturdy mechanism for ensuring trouble free movement and positioning of microphone complete as per specification no. PA-MFS.
906Supplying, Installing, testing and commissioning of Dual channel UHF wireless microphone & receiver, including 2 handheld dynamic transmitters with operating range of minimum 30 mtr distance in line of sight between transmitter & receiver and with 2 x 1.5V batteries of suitable size and and Current consupmtion <150mA, RF power output 10mW or higher suitable for frequency stability +/-0.005%, frequency response 50-15000Hz, channel frequency display & receiver with 220V-240V AC 50Hz AC Adaptor, distortion - /< 1% S/N ratio 100 dB suitable for same frequency as transmitter having controls like ON/OFF Switch, Volume control for both channels, LED indicators for RF & Audio Signal, channel frequency displays & operates on 12V DC through an AC adaptor complete as per specification no. PA-DPA-UHF
907Supplying Installing, testing and commissioning of PA Gooseneck Microphone with Base and frequency response 50-16000Hz, 150Ω to 200Ω impedence, sensitivity 3 to 5.5mV/PA with minimum length(excluding pedestal) of 585mm(23\\") long, felxible stem gooseneck condenser microphone & Heavy Duty Metal Base having on/off switch, LED indication and Suitable for 48V phantom supply as per specification no. PA-GM
908Supplying and erecting PVC trunking (PVC casing-n-capping) of size 20mm with accessories on wall/ceiling as per specification no. WG-MA/CON.
909Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25mm with accessories on wall/ceiling as per specification no. WG-MA/CON.
910Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following featuresImage Sensor : minimum 1/2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°, 4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°, 6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity- minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White, 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. , Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, , IP67, IK10 - Vandal Resistant. , Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight CompensationEvents : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. Operating temperature ( -30 to 60° C ) . , Security- User account and password protection, HTTPS, IP filter, IEEE 802.1X,, digest authentication, user access log, TLS1.2, AES- 256, SSH/Telnet closed,FTP disabled. , Protocol- DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,, SNMP and Secure shell (SSH) supported protocol. , RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified. ,duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as perspecification no. CCTV-CAM.
911Supplying & erecting of High definition 4/5 Megapixel IP IR varifocal Bullet Camera with following featuresImage Sensor : minimum 1/ 2.8\\" Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520 Video compression : H.264, H.265 or higher, at least Three individually, configurable stream, Frame Rate : minimum 25 fps at all resolutions. WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type: 2.8 - 13mm Lens, auto/motorized varifocal focal, Field of View : horizontal FOV 103° to 32°, vertical FOV 73° to 24°, diagonal , FOV 142° to 40°Lux sensitivity- minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance Min IR- 50m, ,Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, , IP67, IK10 – Vandal Resistant, , built in micro SD/SDHC/SDXC card slot of min 128 GB, , built in microphone. , minimum Input/Output- Audio in × 1, Audio Out × 1 , Alarm in× 1, AlarmOut × 1. , Image Settings: Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. , Image Enhancements: Day/ Night-Auto (ICR)/Color/Black & White, 3D Digital, Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight, Compensation, Highlight CompensationEvents: Privacy Masking, Motion detection, Scene change detection, Face, capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection. , Operating temperature ( -30 to 60° C ) . Security- User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES-256, SSH/Telnet closed, FTP disabled. Protocol- DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,, SNMP and Secure shell (SSH) supported protocol. , RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent, BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting, height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM.
912Supplying, installing, testing & commissioning of 32/40 Ch Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI1/VGA1 outputs, provided Atleast one HDMI output of 4K resolution, atleast one VGA output with output up to 1920x1080, Support H.265 or higher, H.264, MJPEG, Supports Redundant Dual Power, Incoming Bandwidth 320 Mbps with minimum 8 SATA ports, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB, minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, support multibrand network Cameras, ONVIF conformance, Multiple network monitoring: Web viewer . support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS. RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specifications no. CCTV-NVR.
913Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD
914Supplying, fixing, and configuring 24 ports, PoE switch compliant with IEEE 802.3 standards with min.193W PoE capacity with 4GE SFP uplink in provided rack as per specification no. WG-NWC/ENS
915Supplying, fixing, and configuring 8-ports 1 GE un-managed gigabit PoE switch compliant with IEEE 802.3 standards, min. 120W PoE capacity with 2GE SFP uplink erected in provided rack complete.
916Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC
917Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 armoured cable suitable for networking compliant with ANSI/TIA-568.2-D standards as per specification no. WG-ELVC/NC
918Supplying, installing and testing UTP connector (RJ-45) as per specification no.WG-NAS/UTPC.
919Supplying, erecting, testing & commissioning of 1 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.8 to unity output pf , single phaseinput & 1 phase output complete with all protections as per specification no. APUPS(Without batteries)
920Supplying, erecting, testing & commissioning of 2 kVA capacity on line puresine wave,PWM,IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. APUPS(Without batteries)
921Supplying and fixing Cat 6, 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 complete as per specification no. WG-NAS/PP
922Supplying, erecting & terminating 5 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete.
923Supplying, erecting & terminating 10 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete.
924Supplying andf ixing 12 ports light guide unloaded interconnect unit, rack mounted type, with adapter panel for terminationof optical fiber cables in provided U rack complete as per specification no. WG-NAS/ LIU
925SITC of SM OS2 LC Pigtail Simplex, 1m
926Supplying & erecting 65\\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 64 channel NVR and following features Brightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg.Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle dulyerected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON.
927Supplying & erecting 55\\" professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W,Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON
928Supplying and erecting modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
929Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMIconnectors complete.
930Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x550x347mm) as per specification no. WG-NAS/RAK
931Supplying and fixing 15U wall mount rack (Dimension-DxWxH – 500x550x747mm) as per specification no. WG-NAS/RAK
932FOH Line Array Cluster - Left:Supply, installation, testing & Comissioning of Front-of- House linearray cluster with each module / box having minimum 14\\" LF driver or better and multiple MF/HF drivers (More than 4), Biamplified 2 or 3 Way array loudspeaker system; with Individual Module free field Frequency Range (-10dB) of 55Hz - 18kHz or better & Continuous Power Handling of >= 750W LF + 150W MF/HF. The Loudspeaker module shall have a Max. SPL (Peak) of MF/HF>= 130 or better. It should have Horizontal near dispersion pattern of 80º or better. Each line array to have minimum 4 array modules / boxes with minimum 70° of total vertical coverage for better control. The Modules shall have a weather rating of IP55.
933FOH Line Array Cluster - Right:Supply, installation, testing & Comissioning of Front-of- House linearray cluster with each module / box having minimum 14\\" LF driver or better and multiple MF/HF drivers (More than 4), Biamplified 2 or 3 Way array loudspeaker system; with Individual Module free field Frequency Range (-10dB) of 55Hz - 18kHz or better & Continuous Power Handling of >= 750W LF + 150W MF/HF. The Loudspeaker module shall have a Max. SPL (Peak) of MF/HF>= 130 or better. It should have Horizontal near dispersion pattern of 80º or better. Each line array to have minimum 4 array modules / boxes with 70° of total vertical coverage for better control. The Modules shall have a weather rating of IP55.
934FOH Line Array Suspension Bracket Accessory:Supply, installation, testing & Commissioning of OEM supplied array frames/ Hanging/ Mounting arrangement for Suspension of upto 4-6 array modules offered above, Shall offer multiple rigging points for achieving desired pitch settings.
935FOH Line Array Coupling Plate Accessory:Supply, installation, testing & Commissioning of coupling plate for line array modules offered above, coupling plates should be supplied from the same OEM of line array speaker for better installation outcome
936FOH Subwoofer:Supply, installation, testing & Commissioning of 18\\" subwoofer having a Freq. Range of 29Hz - 263Hz. It should have an ground stack position Sensitivity of > = 96dB (1W/1m) or more delivering a ground position Max. Calculated SPL(peak) of >=130 db. The loudspeaker should have a nominal impedance: 8ohm or more and Continuous AES Power Handling of 800W or more, Peak AES Power Handling of 3200W or more. Shall be enclosed in exterior grade Plywood. Should be IP55 Environmental rated.
937Subwoofer Brackets:Supply, installation, testing & Commissioning of Supsension & Coupling Bracket for Subwoofers.
938Front Fill Speakers:Supply, installation, testing and commissioning of two-way 5.25-inch or better high SPL IP55 rated surface mount loudspeaker. The louspeaker shall meet the following performance criteria: Frequency Range (-10 dB) of 90Hz - 18 kHz or better; Nominal Dispersion : 90°H x 80°V or better; Power handling of 400W peak or more; Sensitivity : 86 dB or better and the Max SPL : 116dB Peak or more with a Nominal impedence of 8 ohms and Integral multi-tap Transformer with selectable tap settings of 10/20/40/80W@70V & 100V; Standard wall mount brackets shall be included
939Delay Speakers:Supply, installation, testing & Comissioning of biamped, coaxial two-way point source loudspeaker with a single 12-15\\" LF driver and compression driver with 3\\" or better Voice coil. Frequency Range (-10dB) of 48 Hz – 20,000 Hz or better & long term Continuous Power Handling of 300W (Low frequency) and 45W for High Frequency driver or better. The Loudspeaker module shall have a Max. SPL (Peak) of MF/HF>= 131 or better. It should have Horizontal dispersion pattern of 110º or better, vertical dispersion of the loudspeaker shall be 60 degrees or better. The loudspeaker shall be enclosed in a baltic birch plywood enclosure with perforated steel grille. Should be environmental rated for IP43 protection or better.
940Stage Monitor Speakers:Supply, installation, testing & Comissioning of biamped, coaxial two-way point source loudspeaker with a single 12-15\\" LF driver and compression driver with 3\\" or better Voice coil. Frequency Range (-10dB) of 60Hz - 20kHz or better. Long term Continuous Power Handling of 300W or better. Peak Power Handling of 2600W or better. The Loudspeaker module shall have a Max. SPL (Peak) of MF/HF>= 131 db or better. It should have Horizontal dispersion pattern of 110º or better, vertical dispersion of the loudspeaker shall be 60 degrees or better. The loudspeaker shall be enclosed in a baltic birch plywood enclosure with perforated steel grille.
941Control Room Speaker:Supply, installation, testing and commissioning of Full range IP55 rated indoor/outdoor surface mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10dB) of 83Hz to 19kHz; Power handling of 80 Watt peak; Nominal Coverage Angle (1 – 4 kHz) 145° × 140°; Sensitivity of 87 dB SPL and Max SPL of 106 dB SPL peak; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/8/16W@70V & 100V. The loudspeaker system shall be comprised of a 2.25-inch woofer; enclosed in engineered-plastics and a powder-coated tamper-resistant steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications. Environmental: IP55 Rated for direct-exposure outdoor installations
942Green Room Speaker:Supply, installation, testing and commissioning of Full range IP55 rated indoor/outdoor surface mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10dB) of 83Hz to 19kHz; Power handling of 80 Watt peak; Nominal Coverage Angle (1 – 4 kHz) 145° × 140°; Sensitivity of 87 dB SPL and Max SPL of 106 dB SPL peak; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/8/16W@70V & 100V. The loudspeaker system shall be comprised of a 2.25-inch woofer; enclosed in engineered-plastics and a powder-coated tamper-resistant steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications. Environmental: IP55 Rated for direct-exposure outdoor installations
943Pre-Function Lobby Speaker:Supply , installation , testing and commissioning of full range ceiling mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10 dB) of 83Hz to 19kHz; Power handling of 80 Watt peak; Nominal Coverage Angle (1 – 4 kHz) 150°; Sensitivity of 86 dB SPL and Max SPL of 105 dB SPL peak; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/8/16W@70V & 100V. The loudspeaker system shall be comprised of a 2.25-inch woofer; enclosed in engineered-plastics with integrated steel backcan and a powder-coated steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications.
944Amplifier Type-1:Supply , installation , testing and commissioning of Class D configurable amplifier with PowerShare Technology a digital signal processing 4 channel power amplifier with total of 4800W power and power sharing feature for Asymmetric power allocation. Shall support Dante Digital as well as Analog line level audio inputs and GPIO connections for muting. Power output: Upto 4x1200W @ 4–8 Ω, 70 V, 100 V , upto 4x1500W @ 2ohms, SNR: 110dB(A) or better, THD+N: <0.1 %, Crosstalk (1 kHz): -70dB or better, A/D and D/A converters: 24-bit, 48 kHz Sample rate converter: 24-bit, 44.1 kHz – 192 kHz, Latency 2.5 ms fixed-latency architecture, Input-to-output signal routing: 4 × 4 matrix signal processing: Matrix mixer, 5-band PEQ, array EQ, band pass, Spkr EQ, limiter, delays, Programmable speaker EQs, Input impedance : 20 kΩ Status indicators: metering LEDs, system status LEDs, power status LEDs Protections: Thermal, excess high/low AC mains voltage, DC, high‑frequency, output short‑circuit, inrush current, clip, peak, etc. Cooling system: variable-speed fan, front-to-back airflow.
945Amplifier Type-2:Supply , installation , testing and commissioning of Class D configurable amplifier with PowerShare Technology a digital signal processing 4 channel power amplifier with total of 2400W power and power sharing feature for Asymmetric power allocation. Shall support Dante Digital as well as Analog line level audio inputs and GPIO connections for muting. Power output: Upto 4x600W @ 4–8 Ω, 70 V, 100 V , upto 4x800W @ 2ohms, SNR: 108dB(A) or better, THD+N: <0.1 %, Crosstalk (1 kHz): -70dB or better, A/D and D/A converters: 24-bit, 48 kHz Sample rate converter: 24-bit, 44.1 kHz – 192 kHz, Latency 2.5 ms fixed-latency architecture, Input-to-output signal routing: 4 × 4 matrix signal processing: Matrix mixer, 5-band PEQ, array EQ, band pass, Spkr EQ, limiter, delays, Programmable speaker EQs, Input impedance : 20 kΩ Status indicators: metering LEDs, system status LEDs, power status LEDs Protections: Thermal, excess high/low AC mains voltage, DC, high‑frequency, output short‑circuit, inrush current, clip, peak, etc. Cooling system: variable-speed fan, front-to-back airflow.
946Amplifier Type-3:Supply , installation , testing and commissioning of class D amplifier with 4 x 300 W Load-independent outputs deliver full channel power to either low-impedance (4-8 Ω) or high-impedance (70/100V) loads without bridging. Amplifier shall have frequency response of 20 Hz to 20 kHz, THD+N at rated power less than 0.04%. Dynamic Range ≥ 100 dBA (at rated power). Audio Latency < 1 ms (any analog or Digital input to loudspeaker output), The amplifier shall meet or exceed the following performance specifications: channel separation (crosstalk) greater than 80 dB. The amplifier shall have 4 line-level inputs with selectable input sensitivity settings ( -10 dBV, 4 dBu and 14 dBu) for balanced line-level inputs and possibility of 8 or more no .of digital Audio channels . The amplifier shall offer a master mute connection for use with external dry contacts, normally open or normally closed, to mute all outputs of the amplifier, Indicators & Controls: Power LED, Input Signal LED, Output Limit LED, Mains Voltage 100 VAC – 240 VAC (±10%, 50/60 Hz).
947Control Room Amplifier:Supply, installation, testing and commissioning of Class D mixer/amplifier with 48 kHz, 24-bit digital signal processing architecture. The mixer/amplifier shall have two output channels and drive 4–8 Ω low-impedance system minimum power output of 160 watts per channel at 4 Ω and 80 watts per channel at 8 Ω. The mixer/amplifier shall have four line-level inputs (two RCA stereo pairs, two 5-pin Euroblock connectors), one Bluetooth wireless signal input, and one paging microphone input (one 4-pin Euroblock connector). The frequency response of the mixer/amplifier shall be 20 Hz to 20 kHz (+0/-3 dB). The THD+N at rated power shall be less than or equal to 0.5%. The channel separation (crosstalk) shall be less than or equal to -58 dB below rated power at 1 kHz. The dynamic range shall be 88 dB. The nominal input sensitivity shall be -8 dBu for line level inputs and -58 dBu for paging microphone inputs.
948Audio DSP :Supply , installation , testing and commissioning of digital audio DSP with 32-bit fixed/floating-point DSP 456 MHz/ARM Cortex-A8 600 MHz processor or better with following features and specifications are required: The audio DSP shall have 12 analog balanced mic/line level inputs and 8 balanced output channels & 8 additional digital output channels on an RJ-45 jack. Each independently controllable . The DSP shall have Dante 64 × 64, primary/secondary, an Ethernet connection for control and programming on an RJ-45 jack, USB audio Micro-B type, stereo in/out, Audio Latency 1.05 ms (analog in to analog out) or less, DSP shall have GPIO – 5 x 5 general-purpose control, Phantom Power +48 VDC, software selectable per input, RS-232/485 ports: RS-232 (DTE) and RS-485 for control devices. DSP shall have Display 256 x 64 OLED with rotary encoder, LED Status Indicators Power/Status, Audio Signal Indication On Display. The audio DSP shall include configurable signal processing, like signal routing and mixing, equalization, filtering, dynamics, delay, room combining, as well as control, monitoring, and diagnostic tools. The audio DSP shall control and proxy all expansion devices and other Dante® endpoints. It shall have following specs : Frequency Response: 18 Hz to 20 kHz, THD+N < 0.003%, Channel Separation (Crosstalk) < -105 dB, Dynamic Range > 115 dB, A-weighted 20 Hz – 20 kHz, analog input to analog output
949100V Analog Volume Controller:Supply, installation, testing & Commissioning of 100 Volt wall volume controllers whereby the volume for 100 V loudspeakers can be adjusted in 11 steps of 3 dB. An integrated 24 Volt relay allows bypassing of the volume controller in priority situations, making sure the message is always clearly heard at maximum volume. Should be supplied with flush or surface mount boxes accessory as per site conditions.
950Drama Professional Shotgun Hanging Mic:Supply, installation, testing & Commissioning of long-barrel electret condenser shotgun microphone, featuring a highly directional hypercardioid/lobar polar pattern with a 30 degree pickup angle. It offers a 40 Hz to 20 kHz frequency response, -33.5 dBV/Pa sensitivity, and 130 dB SPL handling, requiring 11-52 VDC phantom power.
951Drama Professional Foot Boundary Mic:Supply, installation, testing & Commissioning of Stage Floor microphone suitable for theatre application, a half-supercardioid polar pattern in vertical plane; electret condenser transducer within low profile rugged housing. Frequency response of 80 Hz to 18,000 Hz or better, free of comb filtering. The microphone shall exhibit excellent off-axis response / rejects sounds behind the mic and help gain-before-feedback. The microphone shall have a sensitivity of 22 mV/Pa or better. The Maximum SPL should be 120 dB or better, with THD no greater than 3 percent. Equivalent noise should 22 dBA or lower. Shall be powered by Phantom Power supply of 48v.
952Lavalier Microphone:Supply, installation, testing & Commissioning of a professional lavalier condenser microphone for theatre / drama applications with 5 mm omnidirectional subminiature microphone. Must be IP57-rated dust-resistant and waterproof design. The microphone must be terminated with a MTQG/TA4F connector. Frequency response of 20 Hz to 20 kHz, a sensitivity of -42.5 dBV/Pa (9 mV), a maximum SPL of 132 dB (1 kHz at 1% THD), a 63 dB signal-to-noise ratio, dynamic range of 101 dB and a 31 dB SPL A-weighted equivalent self-noise. The unit must be compatible with wireless bodypack transmitter from same OEM.
953Headworn Microphone:Supply, installation, testing & Commissioning of a professional headworn condenser microphone for theatre / drama applications with 5 mm omnidirectional subminiature microphone. Must be IP57-rated dust-resistant and waterproof design. The microphone must be terminated with a MTQG/TA4F connector. Frequency response of 20 Hz to 20 kHz, a sensitivity of -42.5 dBV/Pa (9 mV), a maximum SPL of 132 dB (1 kHz at 1% THD), a 63 dB signal-to-noise ratio, dynamic range of 101 dB and a 31 dB SPL A-weighted equivalent self-noise. The unit must be compatible with wireless bodypack transmitter from same OEM.
954Digital Wireless Bodypack Transmitter:Supply, installation, testing & Commissioning of bodypack digital wireless transmitter that must deliver 24-bit digital audio with a 120 dB dynamic range and a wide 44 MHz UHF tuning bandwidth. The unit must features a 4-pin male mini connector (TA4M) for use with lavalier, headworn, or instrument cables, and should offer selectable 1/10mW RF output power for up to 330 ft (100m) range. The transmitter shall provide up to 8 hours of operation via two AA batteries or rechargeable Lithium-ion batteries. The transmitter shall have a toggle power on/off or mute / unmute switch. The transmitter shall have a high-contrast OLED display indicating channel name, battery status, and frequency. Must be compatible with receivers from same OEM.
955Digital Wireless Handheld Transmitter Microphone:Supply, installation, testing & Commissioning of digital wireless handheld microphone transmitter with supercardioid dynamic capsule, must deliver 24-bit digital audio with a 118 dB dynamic range, Frequency Range 20 Hz to 20 kHz and a wide 44 MHz UHF tuning bandwidth. The transmitter shall provide up to 8 hours of operation via two AA batteries or rechargeable Lithium-ion batteries. The transmitter shall have a toggle power on/off or mute / unmute switch. The transmitter shall have a high-contrast OLED display indicating channel name, battery status, and frequency. Construction shall be of rugged metal housing. Must be compatible with receivers from same OEM.
956Digital Wireless Dual Channel Receiver:Supply, installation, testing & Commissioning of a dual-channel, half-rack digital wireless receiver that must deliver 24-bit digital audio with a 118 dB dynamic range and 20 Hz to 20 kHz frequency response, digital predictive switching diversity. The receiver must operate over 44 MHz tuning bandwidth with up to 32 compatible systems per band. The housing must be rugged metal construction, a high-contrast LCD menu for intuitive management, Ethernet networking capabilities for system monitoring and Third-party control compatibility. Must be compatible with transmitters from same OEM.
957Active directional UHF antenna:Supply, Installation, Testing and Commissioning of Active directional UHF antenna with integrated amplifier for improved wireless signal reception should compatible with all wireless receivers and antenna distribution systems that provide 12 V DC bias, four-position gain selector switch, low-noise signal amplifier that compensates for transmission loss in coaxial cable, integrated threaded adapter that mounts easily to microphones stands, legendary quality and reliability. Must be from same OEM as the Microphone Transmitters & Receivers.
958Co-axial antenna cable :Supply, Installation, Testing and Commissioning of coaxial antenna cable should have BNC type connector, 50 ohm impedance, should run up to 100 feet. Must be from same OEM as the Microphone Transmitters & Receivers.
959Antenna Distribution System:Supply, Installation, Testing and Commissioning of wideband antenna distribution system with power cables should allow for the expansion of wireless microphone systems by splitting one pair of antennas to multiple receivers, should amplifies RF signals to compensate for insertion loss that results from splitting signal power to multiple outputs. System should support up to five wireless receivers, maximum five systems should be used in a two-tiered configuration. System should have fiveway RF signal output, should support above wireless microphone receivers, should be with front mounting antenna hardware and rack mounting hardware, should have 4 x DC power feeds, 12 V DC outputs for antenna bias. , impedance- 50 Ω, RF Input/output Antenna Connector Type-BNC. Must be from same OEM as the Microphone Transmitters & Receivers.
960Gooseneck Microphone :Supply, Installation, Testing and Commissioning of a 18-inch (45.7 cm) gooseneck-mounted electret condenser microphone designed for speech and vocal pickup. It must have a supercardioid cartridge providing excellent off-axis rejection, a high-sensitivity -33.5 dBV/Pa, balanced transformerless output, and a total frequency response of 50 Hz to 17 kHz, Maximum SPL: 122.7 dB, Dynamic Range: 96.2 dB, Signal-to-Noise Ratio: 67.5 dB, Power Requirements: 11 to 52 VDC phantom power. It must includes a built-in mute switch with a green LED status indicator and an attached XLR preamp.
961Dynamic Vocal Wired Microphone :Supply, Installation, Testing and Commissioning of a cardioid dynamic vocal microphone with integrated on/off sliding switch. It must include a built-in pneumatic shock-mount system to cut down handling noise and a spherical mesh grille with an effective wind and pop filter. Rugged construction with die-cast metal body. Frequency response of 50 to 15,000 Hz, Maximum SPL: 94 dB SPL, -56 dBV/Pa (1.6 mV) sensitivity at 1 kHz, Output Impedance of 150-ohm. Must be supplied with break-resistant stand adapter which rotates 180 degrees,
962Condenser Instrument Wired MicrophoneSupply, Installation, Testing and Commissioning of a professional small-diaphragm electret condenser microphone designed for detailed instrument and vocal reproduction, characterized by its flat, natural response. It should have a cardioid polar pattern, an ultra-thin diaphragm for fast transient response, and a transformerless Class-A preamplifier designed to minimize noise and distortion. The microphone should have frequency response of 20Hz–20kHz, a sensitivity of -41 dBV/Pa, and includes a switchable -15dB pad, it should be able to handle high sound pressure levels (SPL) of 150dB (or 165dB with the pad engaged).
963Condenser Vocal Wired MicrophoneSupply, Installation, Testing and Commissioning of premium handheld electret condenser vocal microphone with a supercardioid polar pattern, designed for professional live sound reinforcement. Frequency response of 50 to 20,000 Hz with a controlled low-frequency roll-off to minimize handling noise and proximity effect. Sensitivity: -52.5 dBV/Pa (2 mV) at 1kHz; Maximum SPL: 140.5 dB (1 kHz at 1% THD); Self-Noise: 23.5 dB (A-weighted); Power Requirements: 11 to 52 Vdc phantom power.
964Long Microphone StandSupply, Installation, Testing and Commissioning of Lightweight long boom stand with tripod base.
965Short Microphone StandSupply, Installation, Testing and Commissioning of Lightweight short stand with tripod base.
966Digital Mixing ConsoleSupply, Installation, Testing and Commissioning of 32-channel digital mixing console with 33 motorized faders, 48 input channels (40 mono + 2 stereo + 2 returns), and 20 Aux buses. It must have 32 D-Pre mic preamps and 1-knob EQ/Compression. 16 XLR outputs, 34x34 USB recording interface, 8 effects processors, and 10 graphic EQs. It should have 1 expansion slot for Dante audio interface card. The Dante audio interface card must be included along with the mixer.
967Digital Dante IO Stage BoxSupply, Installation, Testing and Commissioning of 2U rack-mountable, Dante-equipped I/O stagebox offering 16 microphone/line inputs (XLR/TRS combo) and 8 analog line outputs (XLR). It should support 96kHz/48kHz sampling rates, +48V phantom power, and low-latency, low-jitter audio via Audinate's Dante networking, including redundant primary/secondary etherCON connectors. Must be from the same OEM as the Digital Mixing console.
968Custom AV Floor Boxes - Type 1Supply, Installation, Testing and Commissioning of Custom 8-Hole Floor Boxes with 4x XLR IN + 1x XLR OUT + 1x SPEAKON + 2x RJ45 Ethercon (in/out)
969Custom AV Floor Boxes - Type 2Supply, Installation, Testing and Commissioning of Custom 8-Hole Floor Boxes with 4x XLR IN + 1x XLR OUT + 1x SPEAKON
970Supply of Podium / Lecturn
971Managed Network Switch for DANTE:SITC of 24x1G Ports, POE+ 300W, 2x1G and 4xSFP Managed Switch. Should have Pro AV profiles / templates built in for Quick and easy configuration.
972Active LED Wall:Supply, Installation, Testing and Commissioning of 400 Inch Diagonal Indoor Active LED Screen which would be of Size approximately 31.50 x 11.00 Feet . Total Size of VideoWall 377.95 x 132.28 (In Inch). It shall have Pixel Pitch of 2.5 mm or less. It shall have 14 bit grayscale. It shall have 320 x 480 module size. It shall have 600 Nits Brightness or more, It shall have refresh rate of 3840 or more, , Viewing angle - Horizontal 160° & Vertical: 160°.The Total Resolution of VideoWall 3840 x 1344 or above. PaneI material shall be die cast aluminium. It shall have 3500:1 contrast ratio.
973Active LED Wall Processor:SITC of a high-performance, stable video control processor, seamless switcher, and scaler designed for demanding 24/7 continuous applications like sports centers, concerts, and security monitoring. Engineered to handle large-scale visual displays,input interfaces—including 2 x HDMI, 2 x USB 2.0, 1 x RJ45, 1 x HDMI 2.0 with HDCP 2.2 support for up to 4096 x 2160 @ 60Hz outputs consisting or higher. operate reliably between 0°C and 45°C, seamless source switching, remote control functions, content monitoring and support USB media, Digital audio out and remote setup.
974Active LED Wall Custom Frame Structure:Supply, Installation, Testing and Commissioning of Wall Mounted base frame which would be site customized structure with maid out of powder coated material with high load bearing capacity & It includes Courier Charges.
97575\\" Repeater DisplaysSupply, Installation, Testing and Commissioning of 75 \\" , 4K UHD , 500 nits Display with 3x HDMI In, DP,Audio, USB 2.0 Inputs & Built in Speakers , external control via RS232, RJ45, IR IN , Contrast ratio 1100:1 should support 16 x 7 Operating Hours
976Ceiling Mount Brackets for Repeater DisplaysSITC of Ceiling bracket Tilt down setting for 75\\" display
97755\\" Confidence displaysSupply, Installation, Testing and Commissioning of 55 \\" , 4K UHD , 500 nits Display with 3x HDMI In, DP,Audio, USB 2.0 Inputs & Built in Speakers , external control via RS232, RJ45, IR IN , Contrast ratio 1100:1 should support 16 x 7 Operating Hours.
978Low Height Trolley Cart for Confidence displaysSupply of Low Profle movable trolley suitable for 55\\" Display should be able Tilt upto 90 degrees with Mild stell material.
97930X PTZ CAMERASupply, Installation, Testing and Commissioning of PTZ camera shall have 1/2.8 HD CMOS 2.38 MP sensor or better. It shall have an option of Auto or Manual White Balance. It shall have S/N Ratio of >55db. It shall have 30x optical zoom or better. It shall have 12x digital zoom or better. It shall have USB 3.0 port for unified communication applications, HDMI/DVI Port for Hardware Equipments & IP interface for monitoring. It shall have RJ-45 network interface for Monitoring applications. It shall support TCP/IP, HTTP Port & RTSP Port shall be configurable. Support configurable site addressing while streaming with Time stamp. It shall support Dual H.264 and H.265 Streams with Option of Full HD, HD and SD resolution. It shall support Video format on USB as well as HDMI of 1080p 60/50 fps, 1080i60/50,1080p30/25,720p 60/50/30/25 fps. Shall have atleast 4 Infra Red Identities. At least one preset shall get recalled whenever camera is powered on. The same shall be removed or saved multiple times. It shall support 60 fps on both USB 3.0 as well as HDMI interface or better. It shall have an RS 232C input and output port as well as RS-422/485 Port for Communication. RJ-45 Control port with TCP/IP Controlling. It shall have at least 200 Position Presets through keyboard or third party controller and at least 9 position presets through IR remote or better. It shall have 74.5° or better field of view. It shall have a Pan Rotation Angle of -170degrees to +170 degrees or better. It shall have a Tilt Rotation Angle of -30 degrees to + 90 degrees or better. It shall support Horizontal and Vertical Flip. It shall be supplied with IR remote control, Control Cable, Mounting bracket, Operation Manual, Mounting Screws and 3 Meters Camera Cable as an included accessory. It shall be CE, BIS, RoHs, FCC, ISO 9001:2015 (Quality Management), ISO 14001:2015 (Environment Management, ISO 27001:2022 (Information Security Management), ISO 50001:2018 (Energy Management) certified.
980CAMERA JOYSTICKSupply, Installation, Testing and Commissioning of 4 port PTZ Camera Controller with Joystick which Control up-to total of 7 or more remote cameras; RS-232, RS-422 control ; upports VISCA and PELCO D protocols; Joystick: 4-axis (Pan/Tilt/Zoom/Focus); Display: OLED; Power Consumption: < 2W or less; Backlight: Auto / Manual.
98122\\" CONTROL ROOM MONITOR DISPLAYSupply, Installation, Testing and Commissioning of 22 inch Full HD LED Backlit IPS Panel with HDMI, DVI,VGA, Audio-IN Ports, Monitor (22MP68VQ) (AMD Free Sync, Response Time: 5 ms, 75 Hz Refresh Rate.
9828x8 Matrix SwitcherSupply, Installation, Testing and Commissioning of eight input by eight output HDMI 2.0 matrix switcher with HDCP 2.2 support and capable of handling resolutions up 4K@60Hz 4:4:4 / 8 bit color with static and dynamic HDR output support for each channel. The matrix features advanced independent EDID management control for each HDMI input as well as an Easy EDID analyzer. The analog and digital audio outputs can be set to follow the HDMI video route or can be independently routed either by API or web control interface. Built in re-clocking circuitry ensures the switcher is backwards compatible with sources with older HDMI version chip sets. The matrix switcher can be controlled via front panel buttons, front panel IR, external IR, remote IR, RS232, and Ethernet. The matrix includes a simple IR remote control to allow IR switching. The matrix also features a full command set for RS232 and Ethernet control with third party control systems, plus control via web user interface.
9831:4 Splitter with 4 HDBT receiversSupply, Installation, Testing and Commissioning of 1x4 4K 18G HDBaseT Distribution Amp / Splitter kit including 4 Receivers. Must have HDMI 2.0 1 input 4 output HDBaseT + 1 HDMI DA with RS232/IR pass-through, Audio de-embedding, and Remote Power. The extender kit must allow for one HDMI signal to be sent to four different locations up to 150 meters away. The distribution amplifier must have 1 local loop HDMI output Along with 4 HDbaseT outputs. Must Allow for Advanced EDID Management.
984HDMI Extender TX-RX setSupply, Installation, Testing and Commissioning of HDMI 2.0 HDBaseT Extension Set, Extend HDMI 2.0 signals up to 4K@60Hz / 4:4:4 up to 70m (4K 40m / 1080P 100m), Complete set Includes TX, RX, power supply, and IR flasher/emitter, Extends bi-directional IR. Flexible PoC (Power on either end), Supports HDR10, HDCP 2.2 compliant, Flexible power design (use power supply at TX or RX).
985Sub-Woofer CableSupply, Installation, Testing and Commissioning of 2 core 12 AWG, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant. Spool of 305 mtrs.
986Speaker Cable Supply, Installation, Testing and Commissioning of 2 core 14 AWG, Twisted, unshielded Speaker cable with stranded annealed bare copper conductors, Semi-rigid PVC insulation, NEC CL3R, CEC CMG, RoHS compliant. Spool of 305 mtrs.
987Audio CableSupply, Installation, Testing and Commissioning of 2 core Twisted, shielded balanced Audio and control cable with 22AWG or better 7 strand annealed bare copper conductors, Semi-Rigid PVC insulation, Riser rated PVC jacket. UL 444, UL 13 CMR rated. Spool of 305 mtrs.
988CAT6A Shielded CableSupply, Installation, Testing and Commissioning of 4 pair shielded/foiled TIA/EIA-568-C Category 6A cable with 23AWG or better Solid annealed bare copper conductors, High-density polyethylene insulation, Flame rated PVC jacket, Overall aluminum/poly foil shield with drain, NEC CMR, CEC CMR FT4, RoHS compliant. Spool of 305 mtrs.
9894- Channel Mic/Audio Snake CableSupply, Installation, Testing and Commissioning of 4 Pair Snake Cable – 24 AWG x 2 core copper conductor, PE insulated, Aluminum foil shielded, PVC Inner Sheathed, PVC Overall Sheathed Snake Cable. Spool of 305 mtrs.
9902 Mtrs. HDMI Patch cableSupply, Installation, Testing and Commissioning of 6' (2 mtr.) High Speed HDMI with Ethernet cable for 3D, 4K, Deep Color applications and installations, 18.0Gbps Bandwidth to support 4K60 4:4:4, shall Support ARC, and all HDCP levels, HDR Certified by HDMI ATC, RoHS, REACH, and TAA Compliant.
991SITC of Connectors & Patch Cords.
992SITC of 42U Rack.
993Loudspeakers:Supply, installation, testing and commissioning of 2-way IP55 rated (as per IEC 529) indoor/outdoor surface mounted music loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10dB) of 59Hz to 20kHz; Power handling of 500Watt peak; Nominal Coverage Angle (1 – 4 kHz) 125° conical; Sensitivity of 90 dB SPL and Max SPL of 117 dB SPL peak; Nominal impedance of 8 Ohms with an Integral multi-tap Transformer with selectable tap settings of 5/10/20/40/80W@100V or better. The loudspeaker system shall be comprised of a powder-coated aluminium grill; 6.5-inch weather-treated woofer and 1.25 inch neodymium dome tweeter coaxially mounted enclosed in engineered-plastics with an In-built waveguide designed to provide uniform area coverage across the loudspeakers frequency range. UL-1480A rated and CE-compliant.
994Subwoofers:Supply, installation, testing and commissioning of a Dual 10-inch IP55 rated (as per IEC 60529) high excursive surface mountable all weather subwoofer. The loudspeaker shall meet the following performance criteria: Frequency Range (-10 dB) of 37Hz - 270Hz; Nominal Dispersion : omni-directional; Power handling of 2500W peak; Sensitivity : 96 dB; Max SPL : 130dB Peak; Nominal impedance of 8 ohms. The loudspeaker system shall be comprised of a Powder-coated finish stainless steel grille with Two-part spray polyurea coating Exterior-grade plywood enclosure; U bracket shall be included.
995Green Room Speaker:Supply, installation, testing and commissioning of Full range IP55 rated indoor/outdoor surface mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10dB) of 83Hz to 19kHz; Power handling of 80 Watt peak; Nominal Coverage Angle (1 – 4 kHz) 145° × 140°; Sensitivity of 87 dB SPL and Max SPL of 106 dB SPL peak; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/8/16W@70V & 100V. The loudspeaker system shall be comprised of a 2.25-inch woofer; enclosed in engineered-plastics and a powder-coated tamper-resistant steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications. Environmental: IP55 Rated for direct-exposure outdoor installations
996Pre-Function Lobby Speaker:Supply , installation , testing and commissioning of full range ceiling mounted music and PA loudspeaker. The loudspeaker shall meet the following performance criteria: Usable Frequency range (-10 dB) of 83Hz to 19kHz; Power handling of 80 Watt peak; Nominal Coverage Angle (1 – 4 kHz) 150°; Sensitivity of 86 dB SPL and Max SPL of 105 dB SPL peak; Nominal impedance of 16 ohms and Integral multi-tap Transformer with selectable tap settings of 2/4/8/16W@70V & 100V. The loudspeaker system shall be comprised of a 2.25-inch woofer; enclosed in engineered-plastics with integrated steel backcan and a powder-coated steel grille. UL-1480 rated and EN54-24 compliant for Life safety/VA applications.
997Amplifier Type-1:Supply , installation , testing and commissioning of class D amplifier with 4 x 300 W Load-independent outputs deliver full channel power to either low-impedance (4-8 Ω) or high-impedance (70/100V) loads without bridging. Amplifier shall have frequency response of 20 Hz to 20 kHz, THD+N at rated power less than 0.04%. Dynamic Range ≥ 100 dBA (at rated power). Audio Latency < 1 ms (any analog or Digital input to loudspeaker output), The amplifier shall meet or exceed the following performance specifications: channel separation (crosstalk) greater than 80 dB. The amplifier shall have 4 line-level inputs with selectable input sensitivity settings ( -10 dBV, 4 dBu and 14 dBu) for balanced line-level inputs and possibility of 8 or more no .of digital Audio channels . The amplifier shall offer a master mute connection for use with external dry contacts, normally open or normally closed, to mute all outputs of the amplifier, Indicators & Controls: Power LED, Input Signal LED, Output Limit LED, Mains Voltage 100 VAC – 240 VAC (±10%, 50/60 Hz)
998Amplifier Type-2:Supply , installation , testing and commissioning of class D amplifier with 2 x 600 W Load-independent outputs deliver full channel power to either low-impedance (4-8 Ω) or high-impedance (70/100V) loads without bridging .Amplifier shall have frequency response of 20 Hz to 20 kHz (+/- 1 dB) for LZ mode,with THD+N at rated power less than 0.04%.The amplifier shall meet or exceed the following performance specifications: channel separation (crosstalk) greater than 80 dB below rated power at 1 kHz. . The amplifier shall have 2 line-level inputs with selectable input sensitivity settings ( -10 dBV, 4 dBu and 14 dBu) for balanced line-level inputs (6-pin Euroblock connector) and possiblity of 4 or more no .of digital Audio channels.
999Amplifier Type-3:Supply , installation , testing and commissioning of class D amplifier with 2 x 1000 W Load-independent outputs deliver full channel power to either low-impedance (4-8 Ω) or high-impedance (70/100V) loads without bridging. Amplifier shall have frequency response of 20 Hz to 20 kHz, THD+N at rated power less than 0.04%. Dynamic Range ≥ 100 dBA (at rated power). Audio Latency < 1 ms (any analog or Digital input to loudspeaker output), The amplifier shall meet or exceed the following performance specifications: channel separation (crosstalk) greater than 80 dB. The amplifier shall have 2 line-level inputs with selectable input sensitivity settings ( -10 dBV, 4 dBu and 14 dBu) for balanced line-level inputs and possibility of 8 or more no .of digital Audio channels . The amplifier shall offer a master mute connection for use with external dry contacts, normally open or normally closed, to mute all outputs of the amplifier, Indicators & Controls: Power LED, Input Signal LED, Output Limit LED, Mains Voltage 100 VAC – 240 VAC (±10%, 50/60 Hz)
1000Audio DSP :Supply , installation , testing and commissioning of Integrated Digital Sound Processor with following specifications;Signal Processor/CPU: 32-bit fixed/floating-point DSP + ARM, 456 MHzMaximum Calculation: 3.6 GIPS / 2.7 GFLOPS, Audio Latency 900 μs (analog in to analog out) or lessAUDIO Input Channels: 4 analog inputs (two unbalanced, two balanced) & 2 analog outputs, 8 Additional digital Outputs; 24 Bit A-D and D-A Convertors; Sampling Rate : 48 kHz; THD : < 0.01 % ; Channel Separation (Crosstalk) : < -105 dB ; Frequency Response 20 Hz - 20 kHz ;Dynamic Range : > 115 dB; 8 Control Inputs and 1 control Outputs; Ethernet Port for third party Control and Monitoring; with browser-based UI facilitates real-time display and control of levels, routing, thresholds, priorities, scheduled events, loudspeaker EQs, plus input and area EQs. Shall Support remote Zone source selection or volume controllers. Phantom Power +48 V, selectable per input, 80 mA max across all channels, The DSP shall have Balanced mic/line or 600 Ω paging input and fully-isolated output for Music On Hold for 600 Ω telephone systems .The DSP shall have ambient noise compensation algorithm .
1001Source Selector / Zone Volume controller:Supply , installation , testing and commissioning of digital zone controllers provide volume and source selection for features a single rotary encoder for volume (knob turn), source selection (knob push) for two sources and mute (knob push and hold) with an illuminated volume and source LED indication.
1002100V Analog Volume Controller:Supply, installation, testing & Commissioning of 100 Volt wall volume controllers whereby the volume for 100 V loudspeakers can be adjusted in 11 steps of 3 dB. An integrated 24 Volt relay allows bypassing of the volume controller in priority situations, making sure the message is always clearly heard at maximum volume. Should be supplied with flush or surface mount boxes accessory as per site conditions.
1003Gooseneck Microphone :Supply, installation, testing & Commissioning of Gooseneck Microphone which shall have gooseneck length of 380mm or more. It shall be condenser Microphone. It shall have Cardioid, Bidirectional as well as Omnidirectional Pickup Pattern or multiple mics needs to be supplied. It shall have Mini XLR/XLR Interface. It shall have Signal to noise ratio of 80 dB or more. It shall have equivalent noise level of 18 dB-A or less. It shall have frequency response of 90Hz to 20KHz or better. It shall be -22dBv@1Pa or better. It shall have Max SPL: 109dB (1% T.H.D, 1KHz) or better. It shall have Mute/Unmute Button with Indication. It shall be supplied with standard 6' Audio Cable as standard Accessory.
1004Wireless Lapel Microphone :Supply, Installation, Testing and Commissioning of Wireless Lapel Microphone which shall have Frequency Modulation. It shall have a S/N ratio of ≥ 109 dBA or better. It shall have THD of ≤ 0.8% or better. It shall have frequency response of 80 to 18,000 Hz (–3 dB) or better. It shall have Balanced XLR Audio output and Unbalanced Audio Output. It shall have Operating Time of 6 Hours or more. It shall have power consumption of less than 10W. It shall have 40 Adjustable Frequencies. It shall have Omnidirectional Polar Pattern. It shall support Max SPL: 125dB (THD>3%) or better. It shall have receiving distance of 40 meters or more.It shall be supplied with Body Pack Transmitter, Lapel Microphone Element, Connecting Cable & 2 AA batteries.
1005Wireless Handheld Microphone :Supply, Installation, Testing and Commissioning of Wireless Handheld Transmitter with Frequency Modulation. It shall have a S/N ratio of ≥ 109 dBA or better. It shall have a THD of ≤ 0.5% or better. It shall have a sensitivity of -95 to -67 dB or better. It shall have a frequency response of 40 to 18,000 Hz (–3 dB) or better. It shall have an audio adjustment range of 40 dB, adjustable in 5-dB steps or better. It shall have maximum SPL of 125dB or more. It shall have Transmission power of 3 to 30 mW. It shall have Operating Distance of 50 meters or more. It shall have a Cardioid pickup Pattern. It shall have indication for Battery, Channel number and working frequency. It shall be supplied with 2 AA batteries.
1006Wireless Microphone Receiver:Supply, Installation, Testing and Commissioning of Wireless microphone Receiver with Frequency Modulation. It shall have a S/N ratio of ≥ 110 dBA or better. It shall have a THD of ≤ 0.5% or better. It shall have a frequency response of 40 to 18,000 Hz (–3 dB) or better. It shall have Frequency Stability of ±10ppm or more. It shall have Transmission power of 3 to 30 mW. It shall have Operating Distance of 50 meters or more. It shall have interface of 2x Balanced XLR Outputs and 1x 6.5mm Mixed Output or better.It shall have Buttons for Channel Select, Gain, Scan and Power Buttons. It shall be supplied with 1 receiver, 1 power supply, 1 rackmount kit. batteries.
1007Analog Mixing ConsoleSupply, Installation, Testing and Commissioning of 10-channel analog mixing console. It must have four \\"D-PRE\\" discrete Class-A microphone preamps with an inverted Darlington circuit. The mixer must have 10 line inputs (4 mono and 3 stereo), a 3-band EQ on all mono channels, and 1-knob compressors on channels 1-2 for easy dynamics control. It should be equipped with high-grade SPX digital effects processor offering 24 editable programs, including reverbs, delays, and modulation. The mixer should support 24-bit/192kHz 2-in/2-out USB audio interface, 48V phantom power, XLR balanced outputs, a rugged metal chassis.
1008Music StreamerSupply, Installation, Testing and Commissioning of Independent streaming audio player; Built-in AirPlay 2 streaming with full metadata to iOS/Android apps, Built-in Google Cast for Audio support with full metadata to iOS/Android apps, Bluetooth Audio, Hi-Res audio streaming support up to 24-bit/192 kHz, USB for Flash or external USB Hard drive-based music collections, Digital (PCM) and Analog Stereo Inputs, Digital or analog output (analog output configurable as fixed or variable) Can be controlled through App from same OEM.
1009Passive XLR Input WallplateSupply, Installation, Testing and Commissioning of Custom 2- XLR input wallplate
1010Managed Network Switch:SITC of 8x1G PoE+ 125W 2x1G and 2xSFP Managed Switch
10114K Laser ProjectorSupply, Installation, Testing and Commissioning of 3 Chip DLP Projector, Light Output - 10000 lumens or more, Resolution - 4k, Contrast Ratio - 25000:1
1012Projector Screen:Supply, Installation, Testing and Commissioning of motorised Projector Screen, 298\\" Diagonal, 16:9 aspect, Matt white.
1013HDMI Extender TX Wallplate-RX setSupply, Installation, Testing and Commissioning of Wall plate Tx-Rx- set that should be a HDBaseT 2.0 extender set that transmits HDMI, audio and RS232 over single category 6 twisted pair cable. It Should transmit 4K resolutions up to 4K@60Hz, 4:2:0 up to 40m / 120’ and 1080P up to 70m / 230’. Should have dedicated 3.5mm audio independent from the HDMI signal. Must be HDCP 2.2 compliant.
10142 Mtrs. HDMI Patch cableSupply, Installation, Testing and Commissioning of 6' (2 mtr.) High Speed HDMI with Ethernet cable for 3D, 4K, Deep Color applications and installations, 18.0Gbps Bandwidth to support 4K60 4:4:4, shall Support ARC, and all HDCP levels, HDR Certified by HDMI ATC, RoHS, REACH, and TAA Compliant,
1015Supplying and fixing 36U floor mount server rack (Dimension-DxWxH800X1000 x1800mm) as per specification no. WG-NAS/RAK
1016Supplying, fixing and configuring hardware wireless controller supporting minimum 100 Indoor/Outdoor AP complete as per specification WGNAS/APWC
1017Supplying, fixing, and configuring manageable wireless router with 2.4Ghz indoor access point, dual-band 802.11 n 300mbps unified wireless access point complete as per specification no. WG-NAS/LAP1
1018Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable with rodent proof and anti termite jacket suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n capping as per specification no. WG-ELVC/NC
1019Supplying, fixing, and configuring 1200 Mbps dual band wireless router having 4 Nos. of 10/100/1000 LAN ports external with 4 nos. of external antennas compliant with IEEE 802.3 standards erected on desktop/wall complete.
1020Supplying, fixing, and configuring 24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification
1021Supplying, fixing, and configuring 20 (1G-RJ45) ports + 4 combo 1G ports + 4 10G (SFP+) ports, layer 3 switch, 6KV surge protection on ethernet port and console port for management & support OSPF, BGP, MPLS, policy basedrouting compliant with IEEE 802.3 standards erected in provided rack complete.
1022Supplying and erecting modular type computer Jack RJ 45 with safety shutter, on provided plate and box with wiring connections complete.
1023Supplying and fixing Cat 6, 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 complete as per specification no. WG-NAS/PP
1024Supplying and fixing 1 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of Cat 6 type, compliant ANSI/TIA-568.2-D standards in position as per specification no. WG-ELVC/PC
1025Supplying and fixing 2 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of cat 6 type compliant ANSI/TIA-568.2-D standards in position as per specification no. WG-ELVC/PC
1026Supplying, installing and testing UTP connector (RJ-45) as per specification no. WG-NAS/UTPC.
1027Supplying and installing FR PVC sheathed HDPE insulated copper cat-6 cable suitable for networking compliant with ANSI/TIA-568.2-D standards in provided conduit/casing-n-capping as per specification no. WG-ELVC/NC
1028SITC of Electric Traction Passenger Lift (Lift -9)with · Rated capacity :- 13 Passenger/884Kg· Floors :- G+7 floor (8Stops/8 Landings)· Travel :- 21 to 29.4 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x 2000mm high· Clear Car size of 1600mm wide x 1350mm deep x 2250mm high· Lift shaft available having clear size of 2400mm wide x 1800mmdeep, 18000mm Pit depth,4800mm Overhead.\\"· Doors type :- COPO/TOPO Doors with frame made from SS 304grade solid(non-claded) sheet of 1.5mm thick in hairline finish for car andall landing doors with SS door architraves/frames The lift doors shallhave minimum 1 hour fire rating (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory)· Lift car enclosure made from SS 304 grade solid(non-claded) sheet of1.5mm, thick with hairline finish with frame made from MS girders,bracing of adequate size with minimum safety factor of 5, with ToeGuard Apron, with necessary false ceiling with LED lights having lightintensity of at least 100 lux in car, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The liftcar interior design shall be done as per the directions of engineer incharge.\\"\\"COP with SS face plate having metallic push buttons with BrailleCode & luminous indicator around button with FPI, scrolling UP/DNLED indicator & with / without attendant key switch, OWD with audiovisualalarm, VAS in Marathi, Hindi & English with intercom system withtelephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic pushbuttons with Braille Code & luminous indicator around button with CPI,Lift car arrival & next travel direction audio-visual indication at alllandings\\"\\"· Lift controller based on microprocessor/ PLC with VVVF Drivehaving closed loop control system, with IBMS compatible havingnecessary port, The Controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices includinglift motor and travel direction protection, protection for phase loss atinput or output, Ascending Car Overspeed Protection etc. variousoperation modes such as maintenance, change direction by attendant, fullload bypass, VIP call operation, self leveling operation, call cancel facility,auto return to home landing, fireman evacuation operation, dooropen/close operation from COP etc. The system can record informationfor minimum 30 latest faults, with Real-time clock management andHandheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength, copper wirefor power & control circuit, with provision for addition of floor/controlcard & allied accessories control panel having enclosure of 1.5mm CRCAsheet with powder coating with IP54 Protection class\\"\\"· ARD complete with necessary SMF VRLA batteries shall be suchthat minimum three consecutive rescue operations can be performedwithout recharging for the maximum travel distance between twoconsecutive served stops. ARD have a suitable audio alarm with visualindication or voice annunciation in the lift car or lift controller to indicate“Low battery”.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2nos minimum 2.0MP FHDIP based vandal proof Dome camera in lift car & in LMR/inside liftshaft top aimed on Lift machinery & controller with NVR kept inLMR/FCC with HDR data backup for 90 days with 20” FHD TVmonitor, to be kept in FCC/LMR as directed by Engineer In Charge.\\"\\"· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assemblymounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wireropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide railsfor car & counter weight with brackets fasteners, counter weight framewith necessary blocks, buffers with necessary support arrangement, MSpit ladder etc. erected with necessary steel work\\"\\"· Minor civil work such as alteration work if any necessary for erectionof landing door frames and it's accessories e.g. sill, header, hole pass etccomplete with plaster finish, civil work for erection buffers, erection oflift machinery, adequate size core cuts if required & scaffolding forerecting guide rails, providing and fixing steel girders/RCC work havingadequate strength for mounting and hoisting lift machine etc. complete asper specification no. LFT.· General: - Job includes entire procedure of obtaining all necessaryerection permissions & \\"\\"License to Work the Lift\\"\\" from ElectricalInspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year fromthe date of commissioning\\"\\"ADD onA1 4 For Lift having 1000mm wide x 2000mm high clear entrance in1.5mm thick SS 304 grade solid(non-claded) landing door [Two panel],this includes all necessary accessories like LOP's with UP/DN buttonsarrows-indicators, extension of guide rails, shaft wiring with trunking,travelling cables, main hoisting ropes/belts, & OSG rope landing doorswith all accessories etc. necessary for the normal safe functioning of liftinstallation complete(B2+B1+LG+UG+G+7 floors,Travel Height =45 m,MRL, COPO Arrangement,12Stops/12 Landings)\\"
1029SITC of Electric Traction Passenger Lift (Lift 3) withRated capacity :- 8 Passenger/544Kg Floors :- G+1 floor (2Stops/2 Landings) Travel :- 3 to 4.2 mtrsLocation of Lift Machine:- MR/MRL Rated speed :- 1.0mps VSCar/Landing door clear opening of 800 mm wide x 2000 mmhighClear Car size of 1100mm wide x 1300mm deep x 2250mm high Lift shaft available having clear size of 1770mm wide x 2000mmdeep, 1600-1800mm Pit depth, 4800mm Overhead. \\"· Doors type :- COPO/TOPO Doors with frame made from SS 304grade solid(non-claded) sheet of 1.5mm thick in hairline finish for car andall landing doors with SS door architraves/frames The lift doors shallhave minimum 1 hour fire rating (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory)· Lift car enclosure made from SS 304 grade solid(non-claded) sheet of1.5mm, thick with hairline finish with frame made from MS girders,bracing of adequate size with minimum safety factor of 5, with ToeGuard Apron, with necessary false ceiling with LED lights having lightintensity of at least 100 lux in car, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The liftcar interior design shall be done as per the directions of engineer incharge.\\"\\"· COP with SS face plate having metallic push buttons with BrailleCode & luminous indicator around button with FPI, scrolling UP/DNLED indicator & with / without attendant key switch, OWD with audiovisual alarm, VAS in Marathi, Hindi & English with intercom system withtelephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic pushbuttons with Braille Code & luminous indicator around button with CPI,Lift car arrival & next travel direction audio-visual indication at alllandings\\"\\"· Lift controller based on microprocessor/ PLC with VVVF Drivehaving closed loop control system, with IBMS compatible havingnecessary port, The Controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices includinglift motor and travel direction protection, protection for phase loss atinput or output, Ascending Car Overspeed Protection etc. variousoperation modes such as maintenance, change direction by attendant, fullload bypass, VIP call operation, self leveling operation, call cancel facility,auto return to home landing, fireman evacuation operation, dooropen/close operation from COP etc. The system can record informationfor minimum 30 latest faults, with Real-time clock management andHandheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength, copper wirefor power & control circuit, with provision for addition of floor/controlcard & allied accessories control panel having enclosure of 1.5mm CRCAsheet with powder coating with IP54 Protection class \\"\\"· ARD complete with necessary SMF VRLA batteries shall be suchthat minimum three consecutive rescue operations can be performedwithout recharging for the maximum travel distance between twoconsecutive served stops. ARD have a suitable audio alarm with visualindication or voice annunciation in the lift car or lift controller to indicate“Low battery”.· · Fireman controller having fireman switch at fire Landing. CCTV surveillance system comprises of 2nos minimum 2.0MP FHDIP based vandal proof Dome camera in lift car & in LMR/inside liftshaft top aimed on Lift machinery & controller with NVR kept inLMR/FCC with HDR data backup for 90 days with 20” FHD TVmonitor, to be kept in FCC/LMR as directed by Engineer In Charge.\\"\\"· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assemblymounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wireropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide railsfor car & counter weight with brackets fasteners, counter weight framewith necessary blocks, buffers with necessary support arrangement, MSpit ladder etc. erected with necessary steel work· Minor civil work such as alteration work if any necessary for erectionof landing door frames and it's accessories e.g. sill, header, hole pass etccomplete with plaster finish, civil work for erection buffers, erection oflift machinery, adequate size core cuts if required & scaffolding forerecting guide rails, providing and fixing steel girders/RCC work havingadequate strength for mounting and hoisting lift machine etc. complete asper specification no. LFT\\"\\"· General:- Job includes entire procedure of obtaining all necessaryerection permissions & \\"\\"License to Work the Lift\\"\\" from ElectricalInspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year fromthe date of commissioning\\"\\"ADD on A For Lift travelling up to six floors or at a speed of 1.0 mps, add asbelow, 2 For Lift having 800mm wide x 2000mm high clear entrance in 1.5mmthick SS 304 grade solid(non-claded) landing door [Two panel], thisincludes all necessary accessories like LOP's with UP/DN buttons-arrowsindicators, extension of guide rails, shaft wiring with trunking, travelingcables, main hoisting ropes/belts, & OSG rope landing doors with allaccessories etc. necessary for the normal safe functioning of liftinstallation complete.B For Full Collective control system, add as below. 1 For Lift travelling above First floor & up to Sixth floor(G+1+2+3+4+5 floor,Travel Height =29.6 m,MRL, COPO Arrangement,6Stops/6 Landings)\\"
1030SITC of Electric Traction Passenger Lift (lift- 4,5 & 6)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- G+2nd+3rd.+4th +5th floor (5Stops/5 Landings)· Travel :- 29.6 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1 to 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2550mm wide x 3100mmdeep, 1600-1800mm Pit depth, 4800mm Overhead.(Compliant to IS 17900 ALL PARTS-LATEST)\\"· Doors type :- COPO/TOPO Doors with frame made from SS 304grade solid(non-claded) sheet of 1.5mm thick in hairline finish for car andall landing doors with SS door architraves/frames The lift doors shallhave minimum 1 hour fire rating (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory)· Lift car enclosure made from SS 304 grade solid(non-claded) sheet of1.5mm, thick with hairline finish with frame made from MS girders,bracing of adequate size with minimum safety factor of 5, with ToeGuard Apron, with necessary false ceiling with LED lights having lightintensity of at least 100 lux in car, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The liftcar interior design shall be done as per the directions of engineer incharge.\\"\\"· COP with SS face plate having metallic push buttons with BrailleCode & luminous indicator around button with FPI, scrolling UP/DNLED indicator & with / without attendant key switch, OWD with audiovisualalarm, VAS in Marathi, Hindi & English with intercom system withtelephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic pushbuttons with Braille Code & luminous indicator around button with CPI,Lift car arrival & next travel direction audio-visual indication at alllandings\\"\\"Lift controller based on microprocessor/ PLC with VVVF Drivehaving closed loop control system ,(consider Triplex Lift control system for 3 nos. microprocessor/PLCbased Lift controllers along with necessary software withprogramming and hardware e.g. logic board, necessarycommunication/control/data cabling laying in rigid PVCconduits/trunking etc. complete), with IBMS compatible havingnecessary port, The Controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices includinglift motor and travel direction protection, protection for phase loss atinput or output, Ascending Car Overspeed Protection etc. variousoperation modes such as maintenance, change direction by attendant, fullload bypass, VIP call operation, self leveling operation, call cancel facility,auto return to home landing, fireman evacuation operation, dooropen/close operation from COP etc. The system can record informationfor minimum 30 latest faults, with Real-time clock management andHandheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength, copper wirefor power & control circuit, with provision for addition of floor/controlcard & allied accessories control panel having enclosure of 1.5mm CRCAsheet with powder coating with IP54 Protection class\\"\\"· ARD complete with necessary SMF VRLA batteries shall be suchthat minimum three consecutive rescue operations can be performedwithout recharging for the maximum travel distance between twoconsecutive served stops. ARD have a suitable audio alarm with visualindication or voice annunciation in the lift car or lift controller to indicate“Low battery”.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2nos minimum 2.0MP FHDIP based vandal proof Dome camera in lift car & in LMR/inside liftshaft top aimed on Lift machinery & controller with NVR kept inLMR/FCC with HDR data backup for 90 days with 20” FHD TVmonitor, to be kept in FCC/LMR as directed by Engineer In Charge.\\"\\"· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assemblymounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wireropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide railsfor car & counter weight with brackets fasteners, counter weight framewith necessary blocks, buffers with necessary support arrangement, MSpit ladder etc. erected with necessary steel work\\"\\"· Minor civil work such as alteration work if any necessary for erectionof landing door frames and it's accessories e.g. sill, header, hole pass etccomplete with plaster finish, civil work for erection buffers, erection oflift machinery, adequate size core cuts if required & scaffolding forerecting guide rails, providing and fixing steel girders/RCC work havingadequate strength for mounting and hoisting lift machine etc. complete asper specification no. LFT.· General: - Job includes entire procedure of obtaining all necessaryerection permissions & \\"\\"License to Work the Lift\\"\\" from ElectricalInspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year fromthe date of commissioning\\"
1031SITC of Electric Traction Passenger Lift (lift-1 & 2)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- G+1st+2nd+3rd.+4th +5th floor (6Stops/6 Landings)· Travel :- 29.6 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2550mm wide x 3100mmdeep, 1800mm Pit depth, 4800mm Overhead.(Compliant to IS 17900 ALL PARTS-LATEST)\\"· Doors type :- COPO/TOPO Doors with frame made from SS 304grade solid(non-claded) sheet of 1.5mm thick in hairline finish for car andall landing doors with SS door architraves/frames The lift doors shallhave minimum 1 hour fire rating (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory)· Lift car enclosure made from SS 304 grade solid(non-claded) sheet of1.5mm, thick with hairline finish with frame made from MS girders,bracing of adequate size with minimum safety factor of 5, with ToeGuard Apron, with necessary false ceiling with LED lights having lightintensity of at least 100 lux in car, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The liftcar interior design shall be done as per the directions of engineer incharge.\\"\\"· COP with SS face plate having metallic push buttons with BrailleCode & luminous indicator around button with FPI, scrolling UP/DNLED indicator & with / without attendant key switch, OWD with audiovisualalarm, VAS in Marathi, Hindi & English with intercom system withtelephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic pushbuttons with Braille Code & luminous indicator around button with CPI,Lift car arrival & next travel direction audio-visual indication at alllandings\\"\\"Lift controller based on microprocessor/ PLC with VVVF Drivehaving closed loop control system (consider Duplex Lift control system for 2 nos. microprocessor/PLCbased Lift controllers along with necessary software withprogramming and hardware e.g. logic board, necessarycommunication/control/data cabling laying in rigid PVCconduits/trunking etc. complete), with IBMS compatible havingnecessary port, The Controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices includinglift motor and travel direction protection, protection for phase loss atinput or output, Ascending Car Overspeed Protection etc. variousoperation modes such as maintenance, change direction by attendant, fullload bypass, VIP call operation, self leveling operation, call cancel facility,auto return to home landing, fireman evacuation operation, dooropen/close operation from COP etc. The system can record informationfor minimum 30 latest faults, with Real-time clock management andHandheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength, copper wirefor power & control circuit, with provision for addition of floor/controlcard & allied accessories control panel having enclosure of 1.5mm CRCAsheet with powder coating with IP54 Protection class\\"\\"· ARD complete with necessary SMF VRLA batteries shall be suchthat minimum three consecutive rescue operations can be performedwithout recharging for the maximum travel distance between twoconsecutive served stops. ARD have a suitable audio alarm with visualindication or voice annunciation in the lift car or lift controller to indicate“Low battery”.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2nos minimum 2.0MP FHDIP based vandal proof Dome camera in lift car & in LMR/inside liftshaft top aimed on Lift machinery & controller with NVR kept inLMR/FCC with HDR data backup for 90 days with 20” FHD TVmonitor, to be kept in FCC/LMR as directed by Engineer In Charge.\\"\\"· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assemblymounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wireropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide railsfor car & counter weight with brackets fasteners, counter weight framewith necessary blocks, buffers with necessary support arrangement, MSpit ladder etc. erected with necessary steel work\\"\\"· Minor civil work such as alteration work if any necessary for erectionof landing door frames and it's accessories e.g. sill, header, hole pass etccomplete with plaster finish, civil work for erection buffers, erection oflift machinery, adequate size core cuts if required & scaffolding forerecting guide rails, providing and fixing steel girders/RCC work havingadequate strength for mounting and hoisting lift machine etc. complete asper specification no. LFT.· General: - Job includes entire procedure of obtaining all necessaryerection permissions & \\"\\"License to Work the Lift\\"\\" from ElectricalInspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year fromthe date of commissioning\\"
1032SITC of Electric Traction Passenger Lift (lift- 7 & 8)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- B2+B1+LG+UG+G+FF floor (6Stops/6 Landings)· Travel :- 20.6 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1 to 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2550mm wide x 3100mmdeep, 1600-1800mm Pit depth, 4800mm Overhead.(Compliant to IS 17900 ALL PARTS-LATEST)\\"· Doors type :- COPO/TOPO Doors with frame made from SS 304grade solid(non-claded) sheet of 1.5mm thick in hairline finish for car andall landing doors with SS door architraves/frames The lift doors shallhave minimum 1 hour fire rating (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory)· Lift car enclosure made from SS 304 grade solid(non-claded) sheet of1.5mm, thick with hairline finish with frame made from MS girders,bracing of adequate size with minimum safety factor of 5, with ToeGuard Apron, with necessary false ceiling with LED lights having lightintensity of at least 100 lux in car, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The liftcar interior design shall be done as per the directions of engineer incharge.\\"\\"· COP with SS face plate having metallic push buttons with BrailleCode & luminous indicator around button with FPI, scrolling UP/DNLED indicator & with / without attendant key switch, OWD with audiovisualalarm, VAS in Marathi, Hindi & English with intercom system withtelephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic pushbuttons with Braille Code & luminous indicator around button with CPI,Lift car arrival & next travel direction audio-visual indication at alllandings\\"\\"Lift controller based on microprocessor/ PLC with VVVF Drivehaving closed loop control system ,(consider Duplex Lift control system for two nos. microprocessor/PLCbased Lift controllers along with necessary software withprogramming and hardware e.g. logic board, necessarycommunication/control/data cabling laying in rigid PVCconduits/trunking etc. complete), with IBMS compatible havingnecessary port, The Controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices includinglift motor and travel direction protection, protection for phase loss atinput or output, Ascending Car Overspeed Protection etc. variousoperation modes such as maintenance, change direction by attendant, fullload bypass, VIP call operation, self leveling operation, call cancel facility,auto return to home landing, fireman evacuation operation, dooropen/close operation from COP etc. The system can record informationfor minimum 30 latest faults, with Real-time clock management andHandheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength, copper wirefor power & control circuit, with provision for addition of floor/controlcard & allied accessories control panel having enclosure of 1.5mm CRCAsheet with powder coating with IP54 Protection class\\"\\"· ARD complete with necessary SMF VRLA batteries shall be suchthat minimum three consecutive rescue operations can be performedwithout recharging for the maximum travel distance between twoconsecutive served stops. ARD have a suitable audio alarm with visualindication or voice annunciation in the lift car or lift controller to indicate“Low battery”.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2nos minimum 2.0MP FHDIP based vandal proof Dome camera in lift car & in LMR/inside liftshaft top aimed on Lift machinery & controller with NVR kept inLMR/FCC with HDR data backup for 90 days with 20” FHD TVmonitor, to be kept in FCC/LMR as directed by Engineer In Charge.\\"\\"· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assemblymounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wireropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide railsfor car & counter weight with brackets fasteners, counter weight framewith necessary blocks, buffers with necessary support arrangement, MSpit ladder etc. erected with necessary steel work\\"\\"· Minor civil work such as alteration work if any necessary for erectionof landing door frames and it's accessories e.g. sill, header, hole pass etccomplete with plaster finish, civil work for erection buffers, erection oflift machinery, adequate size core cuts if required & scaffolding forerecting guide rails, providing and fixing steel girders/RCC work havingadequate strength for mounting and hoisting lift machine etc. complete asper specification no. LFT.· General: - Job includes entire procedure of obtaining all necessaryerection permissions & \\"\\"License to Work the Lift\\"\\" from ElectricalInspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year fromthe date of commissioning\\"
1033SITC of Electric Traction Passenger Lift (lift-10)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- LG+UG+G+FF+ FF Mezz.+2nd+3rd+3rd Mezz. floor (8Stops/8 Landings)· Travel :- 25.9 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2700mm wide x 3600mmdeep, 1800mm Pit depth, 4800mm Overhead.(Compliant to IS 17900 ALL PARTS-LATEST)\\"· Doors type :- COPO/TOPO Doors with frame made from SS 304grade solid(non-claded) sheet of 1.5mm thick in hairline finish for car andall landing doors with SS door architraves/frames The lift doors shallhave minimum 1 hour fire rating (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory)· Lift car enclosure made from SS 304 grade solid(non-claded) sheet of1.5mm, thick with hairline finish with frame made from MS girders,bracing of adequate size with minimum safety factor of 5, with ToeGuard Apron, with necessary false ceiling with LED lights having lightintensity of at least 100 lux in car, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The liftcar interior design shall be done as per the directions of engineer incharge.\\"\\"· COP with SS face plate having metallic push buttons with BrailleCode & luminous indicator around button with FPI, scrolling UP/DNLED indicator & with / without attendant key switch, OWD with audiovisualalarm, VAS in Marathi, Hindi & English with intercom system withtelephone instrument in Lift car, LMR & FCC/ground floor· LOP with SS face plate having recess/surface push button box for alllandings with scrolling UP/DN LED indicator having metallic pushbuttons with Braille Code & luminous indicator around button with CPI,Lift car arrival & next travel direction audio-visual indication at alllandings\\"\\"Lift controller based on microprocessor/ PLC with VVVF Drivehaving closed loop control system (Full Collective), with IBMS compatible havingnecessary port, The Controller shall have necessary Protections such asovercurrent, overvoltage, over speed, overheat for all devices includinglift motor and travel direction protection, protection for phase loss atinput or output, Ascending Car Overspeed Protection etc. variousoperation modes such as maintenance, change direction by attendant, fullload bypass, VIP call operation, self leveling operation, call cancel facility,auto return to home landing, fireman evacuation operation, dooropen/close operation from COP etc. The system can record informationfor minimum 30 latest faults, with Real-time clock management andHandheld keypad with LCD screen for view and setting of parameters,The control panel duly wired with proper size & strength, copper wirefor power & control circuit, with provision for addition of floor/controlcard & allied accessories control panel having enclosure of 1.5mm CRCAsheet with powder coating with IP54 Protection class\\"\\"· ARD complete with necessary SMF VRLA batteries shall be suchthat minimum three consecutive rescue operations can be performedwithout recharging for the maximum travel distance between twoconsecutive served stops. ARD have a suitable audio alarm with visualindication or voice annunciation in the lift car or lift controller to indicate“Low battery”.· Fireman controller having fireman switch at fire Landing.· CCTV surveillance system comprises of 2nos minimum 2.0MP FHDIP based vandal proof Dome camera in lift car & in LMR/inside liftshaft top aimed on Lift machinery & controller with NVR kept inLMR/FCC with HDR data backup for 90 days with 20” FHD TVmonitor, to be kept in FCC/LMR as directed by Engineer In Charge.\\"\\"· Lift Machine of Gearless PMSM of suitable kW with duty cycle ofminimum 120 starts/hr (with submission of necessary valid TestCertificate issued by NABL accredited or Independent Test laboratory),with Traction pulley, OSG, electromagnetic brakes, entire assemblymounted on adequate size girders duly fixed on LMR floor/ shaft wallscomplete with main/diverter traction sheaves, suspension wireropes/belts of adequate size & strength· Other mechanical parts such as 'T' section adequate size guide railsfor car & counter weight with brackets fasteners, counter weight framewith necessary blocks, buffers with necessary support arrangement, MSpit ladder etc. erected with necessary steel work\\"\\"· Minor civil work such as alteration work if any necessary for erectionof landing door frames and it's accessories e.g. sill, header, hole pass etccomplete with plaster finish, civil work for erection buffers, erection oflift machinery, adequate size core cuts if required & scaffolding forerecting guide rails, providing and fixing steel girders/RCC work havingadequate strength for mounting and hoisting lift machine etc. complete asper specification no. LFT.· General: - Job includes entire procedure of obtaining all necessaryerection permissions & \\"\\"License to Work the Lift\\"\\" from ElectricalInspector(Lifts) with submission to the Engineer In Charge.· The above rate includes Fully Comprehensive AMC for one year fromthe date of commissioning\\"
1034SITC of Annual Maintenance Contract (AMC) for 3 years after DLP period for Electric Traction Passenger Lift (Lift -9)with · Rated capacity :- 13 Passenger/884Kg· Floors :- G+7 floor (8Stops/8 Landings)· Travel :- 21 to 29.4 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x 2000mm high· Clear Car size of 1600mm wide x 1350mm deep x 2250mm high· Lift shaft available having clear size of 2400mm wide x 1800mmdeep, 18000mm Pit depth,4800mm Overhead. And cost added for Compliant to IS 17900 ALL PARTS-LATEST.
1035SITC of Annual Maintenance Contract (AMC) for 3 years after DLP period for Electric Traction Passenger Lift (Lift 3) withRated capacity :- 8 Passenger/544Kg Floors :- G+1 floor (2Stops/2 Landings) Travel :- 3 to 4.2 mtrsLocation of Lift Machine:- MR/MRL Rated speed :- 1.0mps VSCar/Landing door clear opening of 800 mm wide x 2000 mmhighClear Car size of 1100mm wide x 1300mm deep x 2250mm high Lift shaft available having clear size of 1770mm wide x 2000mmdeep, 1600-1800mm Pit depth, 4800mm Overhead. And cost added for Compliant to IS 17900 ALL PARTS-LATEST.
1036SITC of Annual Maintenance Contract (AMC) for 3 years after DLP period for Electric Traction Passenger Lift (lift- 4,5 & 6)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- G+2nd+3rd.+4th +5th floor (5Stops/5 Landings)· Travel :- 29.6 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1 to 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2550mm wide x 3100mmdeep, 1600-1800mm Pit depth, 4800mm Overhead.
1037SITC of Annual Maintenance Contract (AMC) for 3 years after DLP period for Electric Traction Passenger Lift (lift-1 & 2)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- G+1st+2nd+3rd.+4th +5th floor (6Stops/6 Landings)· Travel :- 29.6 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2550mm wide x 3100mmdeep, 1800mm Pit depth, 4800mm Overhead.
1038SITC of Annual Maintenance Contract (AMC) for 3 years after DLP period for Electric Traction Passenger Lift (lift- 7 & 8)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- B2+B1+LG+UG+G+FF floor (6Stops/6 Landings)· Travel :- 20.6 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1 to 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2550mm wide x 3100mmdeep, 1600-1800mm Pit depth, 4800mm Overhead.
1039SITC of Annual Maintenance Contract (AMC) for 3 years after DLP period for Electric Traction Passenger Lift (lift-10)with · Rated capacity :- 26 Passenger/1768Kg· Floors :- LG+UG+G+FF+ FF Mezz.+2nd+3rd+3rd Mezz. floor (8Stops/8 Landings)· Travel :- 25.9 mtrs· Location of Lift Machine:-MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 1200 mm wide x 2000mm high· Clear Car size of 1600mm wide x 2400mm deep x 2250mm high· Lift shaft available having clear size of 2700mm wide x 3600mmdeep, 1800mm Pit depth, 4800mm Overhead.
1040SITC of Indoor Type Escalator for Passenger (From Ground to First floor) in Upward direction (Mentioned escalator is adjacent to another escalator)*Vertical Rise – 5200 mm*Max. Load(People Per Hour) -6000 to 8000 .*Drive System- VVVF Drive .*Degree of inclination -30 degrees .*Step width =1000mm.*Pit at lower end of escalator =1200 mm from FFL.*Speed =0.5 m/s.\\"*Horizontal Step- 3/3 steps\\"* 415V, 50Hz,Three Phase Supply,Suitable kW Motor and 220/240V, 50Hz,Single Phase Supply,Suitable kVA Illumination Power(For Skirting & Handrail Illumination -Includes Comb lighting).*Handrail in stainless steel finish(with Colour options).* Balustrade Profile/Cladding-S.S. Hairline Finish*Balustrade Panel -Tempered Safety Glass 12 mm*Balustrade height -1000 mm
1041SITC of Indoor Type Escalator for Passenger (From First to Ground floor) in Downward direction (Mentioned escalator is adjacent to another escalator)*Vertical Rise – 5200 mm*Max. Load(People Per Hour) -6000 to 8000 .*Drive System- VVVF Drive .*Degree of inclination -30 degrees .*Step width =1000mm.*Pit at lower end of escalator =1200 mm from FFL.*Speed =0.5 m/s.\\"*Horizontal Step- 3/3 steps\\"* 415V, 50Hz,Three Phase Supply,Suitable kW Motor and 220/240V, 50Hz,Single Phase Supply,Suitable kVA Illumination Power(For Skirting & Handrail Illumination -Includes Comb lighting).*Handrail in stainless steel finish(with Colour options).* Balustrade Profile/Cladding-S.S. Hairline Finish*Balustrade Panel -Tempered Safety Glass 12 mm*Balustrade height -1000 mm
1042Supplying, installing, testing and commissioning of micro processor basedintelligent addressable main fire alarm panel, central processing unit with the 8 loop capacity and capable of supporting not less than 250 devices and detectorsper loop, with on-board LCD alphanumeric backlit display suitable for minimum80 characters, operating at 230 V 50 HZ- AC with inbuilt Battery Backup of aminimum 24 hours in normal condition and 30 minutes in alarm condition, Thepanel shall have suitable provision for network connectivity & compatible forthird party integration(Open Protocol to communicate) via aMODBUS/BACNET interface etc. conforming to IS 15908:2021, IS 2189: 2008, NFPA-72, EN 54 / VdS/FM & UL 864(10th edition) with 3 years replacementwarranty and inclusive of lifetime software license validity , as per specification noFF-AFAS/CP.
1043Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, minimum 10\\" LCD or LED display with resistive touch screen or function keys and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels or on-board LCD alphanumeric backlit display suitable up to 640 characters with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel shall conforming to IS 15908:2021, IS 2189:2008, NFPA-72, EN 54 / VdS/FM & UL with 3 years replacement warranty FFAFAS/RP. (Compatible with modular FAS panel from 4 loop upto 10 Loop Fire Alarm Control Panel), as per specification no FF-AFAS/RP
1044Supplying, installing, testing and commissioning of Addressable Optical Photo Smoke Detector. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have single/twin bicolour LED for 360 deg viewing. The detector is conforming to IS 2189: 2008, 11360_1985_Reff2020_EN 54 /VdS / UL & FM approved with 3 years equipment replacement warranty, Designed to meet UL268, 7th Edition. FFAFAS/SD.
1045Supplying, installing, testing and commissioning of intelligent addressablethermal/heat detector with fixed temperature thermistor with 0°C to 88°Ctemperature range, complete with base as required, single/twin LED’s with 360 degree view, in-built locking mechanism to check the removal and pilferage of the detector, . Detector Shall conforming to IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 / EN 54 / VdS / UL & FM approved with 3 years equipment replacement warranty, Designed to meet UL268, 7th Edition, , as per specification no FF-AFAS/HD - ROR.
1046Supplying, erecting testing and commissioning beam smoke detector four wire single ended reflected type with 8 \\" receiver having digital display for easy alignment, adjustable sensitivity & heater kit for transmitter/receiver and reflector with necessary connections on suitable back box. The protection range of beam detector is 5 to 100 Meters.
1047Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
1048Supplying, installing, testing and commissioning of addressable firecontrol/ relay module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs etc., Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 reed relays / EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FFAFAS/CRM-FCM
1049Supplying, installing, testing and commissioning of addressable fire monitor module for flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 Reed relays, EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MM
1050Supplying, installing, testing and commissioning of addressable fire isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. module complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982, , EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, FF-AFAS/ISM
1051Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories, Module shall conform to EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MCP.
1052Supplying, installing, testing and commissioning of Addressable Sounder cum Strobe rated at minimum 75 dB @ 3m for Audible annunciation and minimum 75cd flashing at 1 Hz for visual indication. Module shall conforming to IS 2189: 2008, IS 15908:2021 / EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/ S-ST
1053Supply, Installation, Testing & Commissioning of Power supply unit (SMPS), input-230AC, output-24V DC @ 2 AMP, to connect to fire alarm panel or NACs, battery backup with built in charging, low battery visual warning with audible tone, DC Output indication.
1054Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
1055Supplying, erecting testing and commissioning Multi Sensor (Smoke + Heat) detector with base on back box, necessary connections complete as per specification no. FF-FAS/MSD
1056Supplying, installing, testing and commissioning of 2 Zone Microprocessor based, conventional fire alarm control panel (FACP) with standard accessories , 16x2 Character LCD Display, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC, complete as per specification no. FF-FAAS/FACP
1057Talk Back Call Station & Talk Back Controller for 10 Zones & call button in Talk Back SpeakerFeatures :* Monitor & Acknowledge Single/Multiple Incoming calls.* Feather type key pads to select the zones.* Buzzer, Display of zone details & LED indication of incoming calls* Backlight Liquid Crystal Display(LCD).*Announcements: Individual Selectable Zones / Multi Selectable Zones / Group Zones/All Zones.* Without disconnecting the current called zone Talk Back Speaker, option for adding others zones Talk Back Speaker* Fault Diagnostics features for Loop in loop out Addressable Talk Back System
1058Addressable Loop in loop out 3 in 1 Talk Back Speaker with Call Button(MS enclosure with Back box)(Hooter, Talk back speaker, Analog Conventional MCP with LED indication and Press to talk button)Features: *Half Duplex communication for PA Speaker “PRESS TO CALL” button for call initiation to control room (Talk Back call Station) *Conventional Fire Alarm Hooter & Manual Call Point (MCP) work without Fire Panel *Indication of MCP & Hooter activated status in Talk Back Call Station *Operates on 6 core cable *Reduces Cable, Conduit and Man power up to 50% to 60% comparing with Basic Talk Back System *Removing the entire Cable, Conduit and Man power 100% of MCP and Hooter *Reduces the overall budget/cost of Talk Back System & Fire Project
1059Supplying, installing, testing and commissioning of 250 Watts amplifier, rack-mount type, suitable for 19” standard equipment rack mounting, occupying 2U height, complete with necessary rack-mounting brackets and hardware. Amplifier shall have 80 Hz–18 kHz frequency response, 4 balanced inputs / 3 stereo line inputs, S/N (flat at max. volume) >70 dB, multiple outputs 4 ohm / 8 ohm / 70 V / 100 V, distortion less than 1% at 1 kHz, separate bass and treble controls, selectable 2-tone chime, complete in all respects.Note : Cable & glands Items added in electrical estimate
1060Supplying, erecting, testing and commissioning of 6 core 1.5 sqmm shielded cable complete.Refer Technical Specifications
1061Supplying & installing of ABC Type Fire Extinguisher Cap. 6 kg Filled with Mono Ammonium Phosphate Powder 50% confirms to IS 4308, Stored Pressure Type, UGTS Pressure Gauge, Discharge Time 24 Sec, Controllable discharge mechanism, Jet Range 5 Meters, Average Discharge is 92%, applicable on Class A,B & C and electrically started Fire, Fire Rating 4A:144B, Can Construction : Deep drawn & CO2 Mig welded, EPDM Rubber Hose with both end Aluminum clamped, Internal Coating - Epoxy Powder coating, External Coating - Pure Polyester Powder coating (UV Resistant), Brass forged valves with safety Pin is of SS material, Made up from 2mm thick sheet, ISI Approved IS 15683:2018.
1062Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg.capacity cartridge type conform to IS 2878 /15683 complete erected withnecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.
1063Supplying & installing of Mechanical Foam stored pressure type 9 ltr. Fire Extinguisher filled with AFFF Foam confirms to IS 4989 (Part-II). Applicable fire class A & B, UTGS Pressure Gauge, Discharge Time 35 Sec, Controllable discharge mechanism, Jet Range 7 Meters, Average Discharge is 95%, Fire Rating- 4A:144B, Can Construction : Deep drawn & CO2 Mig welded, Controllable discharge mechanism with EPDM Hose & Air aspirated Nozzle, External Pure polyester powder coated (UV resistant) and Internal Plastic lining, Brass forged valves with safety Pin is of SS material, Made up from 2 mm thick sheet, As pe IS 15683:2018 and ISI Marked.
1064Supplying & installing of Mechanical Foam type 45 ltr. Fire Extinguisher filled with AFFF Foam (6%), trolley mounted, Applicable fire class A&B, Controllable Discharge mechanism, Discharge Time min. 30-160 Sec, Jet Range 9 Meters, Average Discharge is 95%, Fitted with EPDM Hose with SS spring of 300mm to avoid kink (4 meter long) & Air aspirated Nozzle, CO2 gas Cartridge of 300 grams. Confirms to IS 4947, External Pure polyester (UV Resistant) and Internal Epoxy polyester powder coated, Brass forged cap, and Welding Procedure approved by TPI with 6G certification. Confroms to IS 16018:2012,Fire rating 20A:233B
1065Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
1066Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
1067Supplying, fixing, connecting, testing and commissioning Of Self Contained Rechargeble LED Emergency Directional EXIT signages, CONVOY Series Egress Routes HRTA Lighting with the following features: Maintained type, Surface mounting Type, multi LED which provides illumination on normal mains power supply and the same lamp coutinues to provide illumination during mains failure on self contained battery source for HRTAL Areas for Escape. ON resumption of mains supply, the lamp switches back to the mains automatically and simultaneously starts recharging the battery to the requred level, LED Escape Route Light with LED lamp Fitting with 3 Hours backup with rechargebal Ni-Mh/Ni-cd battery, Directional as requred, paint & Colour in Epoxy polyester powder coating, White in colour., Made up of CRCA Sheet steel -22 SWG, with 16 to 24 hours Recharging period with constant current charger. Input - 230V 50 HZ, CE Certified, ROHS Certifide, Confirms to IS: 10322.
1068Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.EXIT SIGNAGESIZE – 300mm(L) x 100mm(HT)
1069Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.STAIRCASE IDENTIFICATION SIGNAGE (DOWN/ UP)SIZE – 300mm(L) x 100mm(HT)
1070Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.FIRE ALARM SIGNAGESIZE – 200mm(L) x 250mm(HT)
1071Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.FIRE EXTINGUISHER SIGNAGESIZE – 200mm(L) x 250mm(HT)
1072Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.HOSE REEL HOSE SIGNAGESIZE – 200mm(L) x 250mm(HT)
1073Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.ASSEMBLY POINT SIGNAGESIZE – 600mm(L) x 600mm(HT)
1074Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.EMERGENCY ESCAPE PLAN SIGNAGESIZE – 420mm(L) x 297mm(HT) (A3)
1075Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.AUTHORISED PERSONNAL SIGNAGESIZE – 300mm(L) x 100mm(HT)
1076Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.STAIRWAY MARKING SIGNSIZE – 200MM(L) x 300mm(HT)
1077Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.DIRECTIONAL EXIT SIGNAGE Size – 300mm(L) x 100mm(HT)
1078Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.DIRECTIONAL EXIT SIGNAGE (for ASSEMBLY POINT DIRECTION)SIZE – 300MM(L) x 100MM(HT)
1079Supplying, installing, testing & commissiong of AUTOGLO Self Maintain Photoluminescent Siganages in 1 mm thick Rigid Sheet ARS 10000 with Strong Self Adhesive, Life : 10- 15 Years ,Weather Proof, Self Extinguising, The Sign not contain any radioactive substances In toxic terms the product is considered as safe, Non Peelable, Non Scratchable, Non Breakable, Silk Screen Printed: high quality paint with UV resistance, As Per PSPA Class - A / DIN 67510 Part with High photoluminescent luminous intensity Certified By Government Of India Lab For A Glow Period > 24 Hrs DRDO & ARAI Certified (To be approved by EIC) the colour Should be RED/GREEN/BLUE/YELLOW with Graphics Symbol in White Confirm As per the IS 9457-2005 ,IS 12349 and NBC Guidline approved by Local Director of Fire and Emergency services/ Client and Consultant.GENERAL SINAGES ROOM/SHAFT NAMES like AHU ROOM,PLUMBING DUCT,SERVER ROOM,UPS ROOM,ELECTRICAL DUCT,HVAC DUCT ETC. SIZE – 300mm(L) x 100mm(HT)
1080Supplying erecting, testing and commissioning of Direct Low Pressure (DLP), automatic electrical cabinet fire suppression system kit comprises of the mild steel cylinder, hydraulic tested to 30kg/cm2 to check for leakages & burst pressure above 110kg/cm2. duly hot phosphate & epoxy powder coated internally and externally more than 65 microns or painted with 1 coat of primer and 2 coats of red enamel paint all complete. The Cylinder assembly is filled with 2kg to 2.27kgs of clean agent gas (FK-5-1-12 UL listed) and pre-pressurized to 15/16 Bar having storage & operating temperature range of (-)17.8deg.C to 54.4deg.C with all important accessories e.g. brass assembly valve with pressure gauge, end of line plug with pressure gauge suitable to connect with provided Linear heat detection tube, complete with mounting bracket assembly, required size rubber grommets, plastic loop clamps, pressure switch and caution & cylinder Labels etc.
1081Supplying and erecting of linear heat detection tube (UL Listed) made from special flexible polymer material having 6 mm outside & 4 mm inside diameter suitable for working pressure of 20 bar having Red RAL 3000 colour with operating rupture temperature between 110 deg C to 120 deg C or 125 deg C to 145 deg C or 170 deg C to 180 deg C. The tube shall be flexible and shall be kink resistant having minimum bending radius of 100 mm complete erected with necessary drilling at panel wall entries duly connecting with provided end line plug fittings, with rubber grommets, plastic loop clips/clamps etc. complete with all accessories
1082Supplying erecting, testing and commissioning of Master Control Unit (MCU) with 12/24Vdc Audio Visual Alarm with wiring to alert discharge of the DLP system suitable to work at 230V AC 50Hz supply with battery backup for minimum 30 minutes in alarm condition, equipped with green LED indicator for healthy system & red LED indicator for discharged system the MCU suitable provide outputs for activation of sounders or to third party devices which may be used for notification.
1083Supply, Installation, testing & commissioning of of 'Screw' type Water-cooled liquid chillers for the following operating conditions.The chillers shall be complete with Screw compressors, Shell & Tube water cooled condensers, Flooded evaporator, Drive Motor, Control panel, First Charge of R-134a Refrigerant, Oil, Expansion Device etc., The chiller shall have stepless capacity control, as per specifications compThe Chiller shall be capable of opearting in open Ambient temperature of 40 Deg.C , Thane. The equipment shall be placed in a covered shed. The Chiller shall use R-134A / R-410C Refrigerant. The Chiller should be installed on Spring Mounted Antivibration mounts. Antivibration Mounts, flexible outlet connections to the Shell & Tube Heatexchangers, Victaulic Couplings etc., to be provided by Chiller Manufacturer as per their standard & recommended practices. lete with Starter Panel. The equipmnet shall necessarily be with Multi Compressors.Water cooled condenser / Evaporator will be of Shell and Tube type. Shell will be fabricated from rolled carbon steel plate with fusion welded seams have carbon steel tube sheets, drilled and reamed to accommodate the tubes; and intermediate tube supports spaced no more than four feet apart. The refrigerant side will be designed & tested in accordance with applicable pressure vessel code. Tubes shall be high-efficiency, internally and externally enhanced type having copper tubes. Each tube will be roller expanded into the tube sheets providing a leak proof seal, and be individually replaceable. The Evaporator shall be provided with Insulation of using 32 mm Thick Nitrile Rubber insulation Finished with Glass Cloth. Micro-processor based controls with alpha-numeric display in English for all operating parameters such as supply voltage, frequency, load current, chilled water inlet, chilled water outlet, condenser inlet and outlet temperature parameters, operating pressures, input power, Condenser & Evaporator Approach etc., as per tender specification.The processor must be fitted with card for external communication for parameters in open protocol such as Bacnet / Lonwroks / Modbus etc.,Power and control hardware including unit disconnecting / isolating Switch (MCCB), one point start-stop, protective MCCBs for electric motors, timer control, safety features for under-voltage and over voltage, single phase preventor, trip circuit with sensing elements for HP/LP/Anti-freeze etc.,The Chiller shall be properly Powder Coated to protect all the exposed components from weathering. The Price should also includes integral refrigerant piping with liquid isolation valves, and wiring, flow swtiches / sensors, accessories as required and called for, automatic and safety controls mounted in central control panel and all mounted on a steel frame.The bidder shall submit a computerized selection sheet of the chiller offered as obtained from the manufacturer along with their offer from the latest AHRI listed software version. Non-submittal of the computerized selection sheet shall be liable for bid rejection. The cooler and condenser shall have applicable pressure code vessel stamping on the nameplate as a standard, without which the machines will be rejected.Chillers Capacity - 270 TR (Actual Capacity)(2W+1S) .The chiller output shall be at the following conditions, The chiller should have Multiple Compressors. The compressor unloading shall be from 25% to 100%.Installation and testing of Chiller including lifting, shifting, placing on foundation on Terrace Floor. The Vendor should inspect the site before quoting and familarise himself with the site situation. The chiller should be covered with Tarpaulin till the installation and handing over of the system, to protect the chiller from weathering and dust. - Chilled Water Out - 7 Deg.C.,Chilled Water In - 12 Deg.C.,Condenser Water Outlet - 36.7 Deg.C.,Condenser Water Inlet - 31.7 Deg.C.,Operating Voltage 440 V + 15%, 50 Hz, 4 Wire, 3 Phase with Earthing and Starter panel.,Chiller Perofrmance shall be as per ARI 550/590,Fouling Factor as per ARI,Evaporator - 0.0001 Btu/Hr.Sq.ft.Deg.F.,Condenser - 0.0025 Btu/Hr.Sq.ft.Deg.F.
1084Supply, Installation, testing & commissioning of Chilled water Pumps Skids as per specifications mentioned below. Please refer Pump Data sheets for more details.All Motor shall be energy efficient type 1 (IE3) with efficiency not less than IS-12615 Motor Ratings & Efficiencies shall be in line with ECBC Code 2017.Factory made chilled water pump skid for Primary pumping for 3 Nos. (2W+1S) complete with SS/Bronze Impeller & Mechanical Seal, with Split casing/End Suction Pumps , each capable of delivering 45.42 LPS at 30 meter head, 3 nos.Y-Strainers, 6 Nos. Butterfly Valves, 3 Nos. Non-Return Valve, 3 Nos. Pressure gauge , 3 Nos. 25mm ball valve for Drain. The skid shall have 150 mm Dia. Individual pump piping . The entire skid shall be mounted on a 'C' channel base frame with vibration isolators.Antivibration Bellows should be provided at inlet & outlet of each Pump. The entire skid shall be coated with Zinc-cromate primer coating and then painted with enamel paint. The entire skid shall be insulated with 32 mm XLPE / Nitrile Rubber Chemically /Physically Crosslinked Insulation with Alufoil capable of UV Protection properties and finally finished with 26 gauge aluminium cladding.
1085Supply, Installation, testing & commissioning of Chilled water Pumps Skids as per specifications mentioned below. Please refer Pump Data sheets for more details.All Motor shall be energy efficient type 1 (IE3) with efficiency not less than IS-12615 Motor Ratings & Efficiencies shall be in line with ECBC Code 2017.Factory made chilled water pump skid for Condenser water pumping for 3 Nos. (2W+1S) complete with SS/Bronze Impeller & Mechanical Seal, with Split casing/End Suction Pumps , each capable of delivering 68.04 LPS at 25 meter head, 3 nos.Y-Strainers, 6 Nos. Butterfly Valves,3 Nos. Non-Return Valve, 3 Nos. Pressure gauge , 3 Nos. 25mm ball valve for Drain. The skid shall have 200 mm Dia. Individual pump piping . The entire skid shall be mounted on a 'C' channel base frame with vibration isolators.Antivibration Bellows should be provided at inlet & outlet of each Pump.
1086Supply, Installation , Testing and commissioning of Induced Draft Cooling Tower with multi Cell complete with FRP Basin, Base Supports in GI, Munters Fills, Nozzels, FRP Moulded Fan, ECBC Code 2007 efficient Fan Motor (IS-12615) at 1400 RPM, Inlet & Outlet & Drain Connections. The Cooling Tower Shall be CTI Approved with advanced drift eliminators. The Cooling Tower shall be of 340 TR Tower capacity / 270 TR AC Capacity working at Thane. The inlet water would be at 36.70 Deg.C and the basin water should be at 31.70 Deg.C. The Cooling tower shall have 1 Fan in each cell, with least power consumption. The total flow rate through cooling tower shall be 245 CMH.
1087Supply, Installation, Testing & Commissioning of online Tube Cleaning System as recommended by the manufacturer, complete with all necessary Piping, Valves, (Balls / Brushes), Diverter Valves, etc., all fitting deemed necessary for trouble free operation of the tube cleaning system. Kindly note that this shall ensure clean heat exchangers and hence allowing maximum efficiency and minumum approach. The system shall be 1:3
1088Supply, Installation, Testing & Commissioning of D'Scal Microprocessor Based frequency generator, frequencies are termed as RODF (Random Operational Digital Frequencies) which are designed to break the existing scale bonds into tiny non-sticky particles. The unit shall be as per details below in Diameter, and complete with 1.5 meter long SS304 Non Magnetic pipe with mating flanges, SS304 Nuts & Bolts, Frequency Generator, Micro Processor Panel, etc. includig all components electrical cables, etc.,-270 TR Chiller- Condenser Side-Dia. 200mm
1089Supply, Installation, Testing & Commissioning of Closed Expansion Tank with Expansion Vessel and Pressurising Pumps (1 working + 1 standby). The tank capacity to be calculated as per the system volume. Expansion tank to be of MS Construction with UV STabilised XLPE Insulation 32 mm thick class 'O' for fire & covered with UV Stabilised Protection, suitable for 1442 GPM / 90.85 LPS for 3 Nos. 270 TR (2W + 1S) Watercooled Screw Chillers. The insulation shall be factory laminated with UV Stabilised Protection, with superior workmanship. The insulation shall be finally finished with 26 Gauge aluminium cladding, for Physical & UV Protection.
1090Supply, Installation, Testing & Commissioning of Air Seperator for Chilled Water in MS construction with SS internal perforated sheet, with XLPE Insulation with Alu Foil / UV Protection insulation of 32 mm thick class 'O' for fire & covered with 26 Gauge Aluminium Cladding with superior workmanship and necessary valves etc., suitable for the following flow rates. 90.85 LPS. The pipe insulation shall be factory laminated with Alufoil, with superior workmanship.
1091Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Manual balancing valve for evaporator outlet 150mm Dia. Evaporator Side
1092Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Motorised Butterfly Valves 150 mm dia. Across 270 TR Chiller Evaporator Side
1093Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Flow Switch - Suitable for 150 mm dia pipe for 270 TR Chiller Evaporator Side
1094Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Differential Pressure Switch - Suitable for 150 mm dia pipe for 270TR Chiller Evaporator Side
1095Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Differential Pressure Transmitter - Suitable for 150 mm dia pipe for 270TR Chiller Evaporator Side
1096Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Chiller Inlet & Outlet Rubber Expansion Bellows - 150 mm Dia for 270 TR Chiller Evaporator Side
1097Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Glycering filled Temperature Gauges - 100mm Dial, with thermowell and necessary hardware
1098Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Glycering filled Pressure Gauges - 100mm Dial and necessary hardware
1099Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Flow Meter - Dia. 250mm
1100Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -2 Way Modulating Valve - Dia. 200mm
1101Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 250mm
1102Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 200mm
1103Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 150mm
1104Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 125mm
1105Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 100mm
1106Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 65mm
1107Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 50mm
1108Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Butterfly Valves - Dia. 40mm
1109Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Ball Valves - Dia. 50mm
1110Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Ball Valves - Dia. 32mm
1111Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Ball Valves - Dia. 25mm
1112Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Ball Valves - Dia. 15mm
1113Supply, installation, testing & commissioning of valves & Gauges with Nitrile Rubber Insulation with Alufoil capable of UV Protection of 32 mm thick. The pipe insulation shall be factory laminated with Alufoil UV Stabilised. All exposed piping shall be finally finished with 26 Gauge Aluminium Cladding.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type) -Automatic Air Vent
1114Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Manual balancing valve for evaporator outlet 200mm Dia. Evaporator Side
1115Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Motorised Butterfly Valves 200 mm dia.
1116Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Flow Switch - Suitable for 200 mm dia pipe for 270 TR Chiller Condenser side
1117Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Differential Pressure Switch - Suitable for 200 mm dia pipe for 270 TR Chiller Condenser side
1118Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Chiller Inlet & Outlet Rubber Expansion Bellows - 200 mm Dia for 270 TR Chiller Condenser side
1119Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Glycering filled Temperature Gauges - 100mm Dial, with thermowell and necessary hardware
1120Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Glycering filled Pressure Gauges - 100mm Dial and necessary hardware
1121Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Butterfly Valves 200 mm dia.
1122Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Butterfly Valves 150 mm dia.
1123Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Butterfly Valves 50 mm dia.
1124Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Butterfly Valves 40 mm dia.
1125Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Ball Valves - Dia. 15mm
1126Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Ball Valves - Dia. 50mm
1127Supply, installation, testing & commissioning of valves & Gauges for Condenser side equipments.(Butterfly valves from Dia.250mm and above should be Handwheel with gear box type)- Immersion type temperature Transmitter for Cooling Tower Sump Temperature
1128Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. - 250 MM dia.
1129Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -200 MM dia.
1130Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -150 MM dia.
1131Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -125 MM dia.
1132Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -100 MM dia.
1133Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -80 MM dia.
1134Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -65 MM dia.
1135Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -50 MM dia.
1136Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -40 MM dia.
1137Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -32 MM dia.
1138Supply, installation, testing & commissioning of M.S. Class \\" C \\" Chilled Water piping with Puff Insulation with UV treated covering of 50 mm thick for pipes 100 mm and above & insulation of 32 mm thick Insulation for pipes upto 80mm Dia. The pipe insulation shall be with UV treated covering. All piping shall be finally finished with 26 Gauge Aluminium Cladding. -25 MM dia.
1139Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 300 MM dia.
1140Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 250 MM dia.
1141Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 200 MM dia.
1142Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 150 MM dia.
1143Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 125 MM dia.
1144Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 100 MM dia.
1145Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 80 MM dia.
1146Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 65 MM dia.
1147Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 50 MM dia.
1148Supply of G.I. Class \\" C \\" Condenser Water piping, with Split Clamp Pipe supports.- 40 MM dia.
1149Supply, installation, testing & commissioning of UPVC Schedule 40 Drain piping as per the required Diameter complete with 9mm thick Nitrile Rubber / XLPE Insulation and finished with Alu Foil. - 25 mm
1150Supply, installation, testing & commissioning of UPVC Schedule 40 Drain piping as per the required Diameter complete with 9mm thick Nitrile Rubber / XLPE Insulation and finished with Alu Foil. - 32 mm
1151Supply, installation, testing & commissioning of UPVC Schedule 40 Drain piping as per the required Diameter complete with 9mm thick Nitrile Rubber / XLPE Insulation and finished with Alu Foil. - 40 mm
1152Supply, installation, testing & commissioning of UPVC Schedule 40 Drain piping as per the required Diameter complete with 9mm thick Nitrile Rubber / XLPE Insulation and finished with Alu Foil. - 50 mm
1153Supply, installation, testing & commissioning of UPVC Schedule 40 Drain piping as per the required Diameter complete with 9mm thick Nitrile Rubber / XLPE Insulation and finished with Alu Foil. - 65 mm
1154Supply, Delivery, Installation, testing & commissioning of Floor Mounted Air handling units in re circulatory configuration with 24G (0.64mm) ore-plasticised G.I. outer skin and 22G (0.8mm) plain G.I. inner skin with 36kg/m3 density PIR insulation having thickness 43±2mm in double skin construction as per air flow diagrams & specifications with following accessories. AHU Shall be including with Mixing chamber with fresh & return air dampers, Cooling Coil, Filters, Plug fans,etc.Thermal break profile at corners and at joints for double skin air handling units along with internal covings.AHU frame shall be made of non corrosive extruded aluminum profile fitted together with polyamide corner pieces.Flange type filters with extruded aluminum flanges along with quick filter fixing arrangement with SS 304 wing nuts.Chilled water cooling coil shall be of copper tubes with aluminum fins and 6 rows deep suitable for chilled water operation.Velociy of coil shoul not be exceed 500 FPM.Drain pan in 16G SS 304 construction along with 25mm nitrile rubber insulation with smooth finish and slope should be provided to have zero retention of water in drain pan. The insulation shall be sandwiched between to sheets of SS 304.Inlet and outlet connection of chilled water shall be on same side.Centrifugal type Direct driven Plug Fans fans with backward curved impellers. Motor shall be 3 Phase induction motor IE 3, TEFC Motor compatible with VFD having EFF1 energy efficiently rating & Electrical cable connection from starter panle to AHU shall be done by HVAC contractor.AMCA certification shall be required for fans.Blower and motor assembly shall be mounted on common base frame with anti vibration mounting pads. (Static Pressure -50mm of WC).Non woven synthetic supported by HDPE mesh on one side and aluminium mesh on the other side. Non flammable.EU -4 Flange type filters with extruded aluminium flanges along with quick filter fixing arrangement with SS 304 wing nuts.Fire retardant flexible canvas connection and cushy foot mounting for fan Unit shall be provided with flanges and low leakage extruded aluminum volume control dampers with positive locking arrangement and percent opening gradations on supply side, return side, fresh air side and purge side in loose condition. - 27000 cfm
1155Supply, Delivery, Installation, testing & commissioning of Floor Mounted Air handling units in re circulatory configuration with 24G (0.64mm) ore-plasticised G.I. outer skin and 22G (0.8mm) plain G.I. inner skin with 36kg/m3 density PIR insulation having thickness 43±2mm in double skin construction as per air flow diagrams & specifications with following accessories. AHU Shall be including with Mixing chamber with fresh & return air dampers, Cooling Coil, Filters, Plug fans,etc.Thermal break profile at corners and at joints for double skin air handling units along with internal covings.AHU frame shall be made of non corrosive extruded aluminum profile fitted together with polyamide corner pieces.Flange type filters with extruded aluminum flanges along with quick filter fixing arrangement with SS 304 wing nuts.Chilled water cooling coil shall be of copper tubes with aluminum fins and 6 rows deep suitable for chilled water operation.Velociy of coil shoul not be exceed 500 FPM.Drain pan in 16G SS 304 construction along with 25mm nitrile rubber insulation with smooth finish and slope should be provided to have zero retention of water in drain pan. The insulation shall be sandwiched between to sheets of SS 304.Inlet and outlet connection of chilled water shall be on same side.Centrifugal type Direct driven Plug Fans fans with backward curved impellers. Motor shall be 3 Phase induction motor IE 3, TEFC Motor compatible with VFD having EFF1 energy efficiently rating & Electrical cable connection from starter panle to AHU shall be done by HVAC contractor.AMCA certification shall be required for fans.Blower and motor assembly shall be mounted on common base frame with anti vibration mounting pads. (Static Pressure -50mm of WC).Non woven synthetic supported by HDPE mesh on one side and aluminium mesh on the other side. Non flammable.EU -4 Flange type filters with extruded aluminium flanges along with quick filter fixing arrangement with SS 304 wing nuts.Fire retardant flexible canvas connection and cushy foot mounting for fan Unit shall be provided with flanges and low leakage extruded aluminum volume control dampers with positive locking arrangement and percent opening gradations on supply side, return side, fresh air side and purge side in loose condition. -23000 cfm
1156Supply, Delivery, Installation, testing & commissioning of Floor Mounted Air handling units in re circulatory configuration with 24G (0.64mm) ore-plasticised G.I. outer skin and 22G (0.8mm) plain G.I. inner skin with 36kg/m3 density PIR insulation having thickness 43±2mm in double skin construction as per air flow diagrams & specifications with following accessories. AHU Shall be including with Mixing chamber with fresh & return air dampers, Cooling Coil, Filters, Plug fans,etc.Thermal break profile at corners and at joints for double skin air handling units along with internal covings.AHU frame shall be made of non corrosive extruded aluminum profile fitted together with polyamide corner pieces.Flange type filters with extruded aluminum flanges along with quick filter fixing arrangement with SS 304 wing nuts.Chilled water cooling coil shall be of copper tubes with aluminum fins and 6 rows deep suitable for chilled water operation.Velociy of coil shoul not be exceed 500 FPM.Drain pan in 16G SS 304 construction along with 25mm nitrile rubber insulation with smooth finish and slope should be provided to have zero retention of water in drain pan. The insulation shall be sandwiched between to sheets of SS 304.Inlet and outlet connection of chilled water shall be on same side.Centrifugal type Direct driven Plug Fans fans with backward curved impellers. Motor shall be 3 Phase induction motor IE 3, TEFC Motor compatible with VFD having EFF1 energy efficiently rating & Electrical cable connection from starter panle to AHU shall be done by HVAC contractor.AMCA certification shall be required for fans.Blower and motor assembly shall be mounted on common base frame with anti vibration mounting pads. (Static Pressure -50mm of WC).Non woven synthetic supported by HDPE mesh on one side and aluminium mesh on the other side. Non flammable.EU -4 Flange type filters with extruded aluminium flanges along with quick filter fixing arrangement with SS 304 wing nuts.Fire retardant flexible canvas connection and cushy foot mounting for fan Unit shall be provided with flanges and low leakage extruded aluminum volume control dampers with positive locking arrangement and percent opening gradations on supply side, return side, fresh air side and purge side in loose condition. -15000 cfm
1157Supply, Delivery, Installation, testing & commissioning of Floor Mounted Air handling units in re circulatory configuration with 24G (0.64mm) ore-plasticised G.I. outer skin and 22G (0.8mm) plain G.I. inner skin with 36kg/m3 density PIR insulation having thickness 43±2mm in double skin construction as per air flow diagrams & specifications with following accessories. AHU Shall be including with Mixing chamber with fresh & return air dampers, Cooling Coil, Filters, Plug fans,etc.Thermal break profile at corners and at joints for double skin air handling units along with internal covings.AHU frame shall be made of non corrosive extruded aluminum profile fitted together with polyamide corner pieces.Flange type filters with extruded aluminum flanges along with quick filter fixing arrangement with SS 304 wing nuts.Chilled water cooling coil shall be of copper tubes with aluminum fins and 6 rows deep suitable for chilled water operation.Velociy of coil shoul not be exceed 500 FPM.Drain pan in 16G SS 304 construction along with 25mm nitrile rubber insulation with smooth finish and slope should be provided to have zero retention of water in drain pan. The insulation shall be sandwiched between to sheets of SS 304.Inlet and outlet connection of chilled water shall be on same side.Centrifugal type Direct driven Plug Fans fans with backward curved impellers. Motor shall be 3 Phase induction motor IE 3, TEFC Motor compatible with VFD having EFF1 energy efficiently rating & Electrical cable connection from starter panle to AHU shall be done by HVAC contractor.AMCA certification shall be required for fans.Blower and motor assembly shall be mounted on common base frame with anti vibration mounting pads. (Static Pressure -50mm of WC).Non woven synthetic supported by HDPE mesh on one side and aluminium mesh on the other side. Non flammable.EU -4 Flange type filters with extruded aluminium flanges along with quick filter fixing arrangement with SS 304 wing nuts.Fire retardant flexible canvas connection and cushy foot mounting for fan Unit shall be provided with flanges and low leakage extruded aluminum volume control dampers with positive locking arrangement and percent opening gradations on supply side, return side, fresh air side and purge side in loose condition. -11000 cfm
1158Supply, Delivery, Installation, testing & commissioning of Floor Mounted Air handling units in re circulatory configuration with 24G (0.64mm) ore-plasticised G.I. outer skin and 22G (0.8mm) plain G.I. inner skin with 36kg/m3 density PIR insulation having thickness 43±2mm in double skin construction as per air flow diagrams & specifications with following accessories. AHU Shall be including with Mixing chamber with fresh & return air dampers, Cooling Coil, Filters, Plug fans,etc.Thermal break profile at corners and at joints for double skin air handling units along with internal covings.AHU frame shall be made of non corrosive extruded aluminum profile fitted together with polyamide corner pieces.Flange type filters with extruded aluminum flanges along with quick filter fixing arrangement with SS 304 wing nuts.Chilled water cooling coil shall be of copper tubes with aluminum fins and 6 rows deep suitable for chilled water operation.Velociy of coil shoul not be exceed 500 FPM.Drain pan in 16G SS 304 construction along with 25mm nitrile rubber insulation with smooth finish and slope should be provided to have zero retention of water in drain pan. The insulation shall be sandwiched between to sheets of SS 304.Inlet and outlet connection of chilled water shall be on same side.Centrifugal type Direct driven Plug Fans fans with backward curved impellers. Motor shall be 3 Phase induction motor IE 3, TEFC Motor compatible with VFD having EFF1 energy efficiently rating & Electrical cable connection from starter panle to AHU shall be done by HVAC contractor.AMCA certification shall be required for fans.Blower and motor assembly shall be mounted on common base frame with anti vibration mounting pads. (Static Pressure -50mm of WC).Non woven synthetic supported by HDPE mesh on one side and aluminium mesh on the other side. Non flammable.EU -4 Flange type filters with extruded aluminium flanges along with quick filter fixing arrangement with SS 304 wing nuts.Fire retardant flexible canvas connection and cushy foot mounting for fan Unit shall be provided with flanges and low leakage extruded aluminum volume control dampers with positive locking arrangement and percent opening gradations on supply side, return side, fresh air side and purge side in loose condition. -6000 cfm
1159Supply, Delivery, Installation, testing & commissioning of Duct mount temperature & RH Transmitter for AHU for modulating VFD speed.
1160Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-7000 cfm
1161Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-6500 cfm
1162Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-6000 cfm
1163Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-5500 cfm
1164Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-5000 cfm
1165Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-4500 cfm
1166Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-3500 cfm
1167Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-3000 cfm
1168Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-2000 cfm
1169Supply ,Installation, Testing, Balancing and Commissioning of VAV boxes SAA duct constructed of 22 G GI sheet with interior accoustic liling of closed cell foam covered with alu foil. A circular damper should have proper sealing & good linearity.The VAV box shall be comprising of sheet metal, insulated box with circular opening(s) & shall be factory connected to the main unit. The circular opening(s) & shall be factory connected to the main unit. The circular opening(s) shall be centered on the unit to accept round dcutwork connections.The VAV box shall be complete with Inlet collar constructed of 22-Gauge galvanized steel sized to fit standard rectangular duct. An integral multiple- point, averaging flow-sensing ring shall be provided with primary airflow measurement within +/-5% of unit cataloged air flow. damper is 22 Gauge galvanised sheet.The damper blade assembly to be connected to a cast zinc shaft supported by self lubricating bearings. The shaft shall be cast with a damper position indicator. The valve assembly shall include a mechanical stop to prevent over-stroking. At 3.0 inch wg air valve leakage does not exceed 6% of maximum airflow.The VAV unit shall be complete and consist of DP, temperature sensor (Digital Thermostat with LCD display), controller for receiving Temp. & DP signal, motorised actuator, etc. complete with mounting flange, power cabling & independently supported of the duct. The VAV controller shall be capable of handling signal from temperature sensor.-1600 cfm
1170Supply, Installation, Testing & Commissioning of Factory Made Chilled water AHU Valve Stations in MS Class 'C' piping, complete with 5 Nos. Butterfly Valves, 2-Way PIBCV Valve with actuator and Sensor , 1 No. Y - Strainer, 2 Nos. Temperature gauge & 2 Nos. Pressure gauge, Dia. 25 mm By-pass line between Supply & Return with Ball Valve & Non Return Valve. The entire skid shall be coated with Zinc - Cromate primer and then painted with enamel paint. The Valve Station shall be insulated using 32 mm thick Nitrile Rubber Insulation, with UV stabilised covering. The Valve Station shall be finally finished with 26 Gauge Aluminium Cladding. The station shall be used for following AHUs: 100mm
1171Supply, Installation, Testing & Commissioning of Factory Made Chilled water AHU Valve Stations in MS Class 'C' piping, complete with 5 Nos. Butterfly Valves, 2-Way PIBCV Valve with actuator and Sensor , 1 No. Y - Strainer, 2 Nos. Temperature gauge & 2 Nos. Pressure gauge, Dia. 25 mm By-pass line between Supply & Return with Ball Valve & Non Return Valve. The entire skid shall be coated with Zinc - Cromate primer and then painted with enamel paint. The Valve Station shall be insulated using 32 mm thick Nitrile Rubber Insulation, with UV stabilised covering. The Valve Station shall be finally finished with 26 Gauge Aluminium Cladding. The station shall be used for following AHUs: 80mm
1172Supply, Installation, Testing & Commissioning of Factory Made Chilled water AHU Valve Stations in MS Class 'C' piping, complete with 5 Nos. Butterfly Valves, 2-Way PIBCV Valve with actuator and Sensor , 1 No. Y - Strainer, 2 Nos. Temperature gauge & 2 Nos. Pressure gauge, Dia. 25 mm By-pass line between Supply & Return with Ball Valve & Non Return Valve. The entire skid shall be coated with Zinc - Cromate primer and then painted with enamel paint. The Valve Station shall be insulated using 32 mm thick Nitrile Rubber Insulation, with UV stabilised covering. The Valve Station shall be finally finished with 26 Gauge Aluminium Cladding. The station shall be used for following AHUs: 65mm
1173Supply, Installation, Testing & Commissioning of Factory Made Chilled water AHU Valve Stations in MS Class 'C' piping, complete with 5 Nos. Butterfly Valves, 2-Way PIBCV Valve with actuator and Sensor , 1 No. Y - Strainer, 2 Nos. Temperature gauge & 2 Nos. Pressure gauge, Dia. 25 mm By-pass line between Supply & Return with Ball Valve & Non Return Valve. The entire skid shall be coated with Zinc - Cromate primer and then painted with enamel paint. The Valve Station shall be insulated using 32 mm thick Nitrile Rubber Insulation, with UV stabilised covering. The Valve Station shall be finally finished with 26 Gauge Aluminium Cladding. The station shall be used for following AHUs: 50mm
1174Supply, Installation, Testing and Commssioning of Chilled Water Cassette unit complete with Cooling Coil, Fan with BLDC Motor, Cordless Remote Control and Drain Pump to remove condensate water etc., Supply, Installation, Testing & Commissioning of Factory made Insulated Chilled Water Cassette unit valve station with Digital thermostat of following sizes as per specification. The cassette unit shall be complete with the insulated box shall comprises of PIBCV valve (equal percentage flow characteristics) with actuator, 25 mm ball valve, ball valve with strainer, bypass arrangement for flushing. The actuator shall be capable of accepting upto 10V DC and upto 20 mA electric signal from PI thermostat. Valve should have pressure rating of 16 bar minimum as per TS.The cost shall be included with 0.5 Meter Length of Hydraulic Hose with hardware shall be consider at both supply & return side for each cassette connection. - 2.0 TR
1175Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
1176Supply, Installation, Testing & Commssioning of Condensate water drain pump for DX Inverter Unit
1177Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
1178Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1179Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1180Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1181Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1182Supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete.
1183Oudoor Units Stands for above Inverter DX Units , fabricated out of Mild Steel (MS) 'C' Channel Section of minimum 75mm x 50mm x 5mm thick size complete with minimum 300mm long legs made of the same 'C' channel with 8mm thick MS Plate at the bottom of the legs. The MS Plate should be minimum 150mm x 150mm. 2 Layered 10mm thick Ribber Rubber Pads with 24 Gauge GI Shim inbetween shall be installed below the Condenser Stand Legs.
1184Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation.
1185Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 375/380 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
1186Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF
1187Supply,Installation,Testing & Commissioning of Cabinet Type fresh air unit in recirculating configuration with 24 gauge (0.64mm) preplasticised G.I outer skin and 22G (0.8mm) plain G.I inner skin with 36kg/m3 density PIR insulation having thickness 25 (+/- 2mm) in double skin construction as per standard details diagrams & specifications. - 4000 CFM,25 mm S.P.
1188Supply,Installation,Testing & Commissioning of Ceiling Mounted Exhaust Fan, including with all Accessories (Static Pressure - 5mm) - 100 CFM,5 mm S.P.
1189Supply ,Installation, Testing and Commissioning of Electrostatic Type Kitchen Exhaust Air Cleaner (Dry Scrubber) complete with the following accessories,components etc. making it a completely functional dry scrubber suitable for Kitchen Hood Exhaust.The component to be included are1. Casing - Shall be made of 0.6mm galvanized pre-plasticized/powder coated sheet on outside and 0.6 mm GI sheet inside with PUF foam of 36 kg/m3 density insulation in between sheets to make 25 mm thick panels.2. Pre Filter Section with Wire Mesh SS Filters for Coarse Particle Removal3. UV chamber for odor removal4. Electrostatic Precipitator Section - Electrostatic section shall be made of 16 gauge galvanized sheet, high bake epoxy powder coated, SS Spiked ionizers to create high voltage DC field, aluminum collector plates which should be alternatively charged positive and negative with large collecting area with deep cell, to work as magnet for charged smoke and oil particles. Average efficiency of 90-95% in single pass as per ASHRAE/DOP test method. Electrostatic Precipitator should be able to charge particles from 0.01 micron to 10 microns through solid state power supply. Collector cell should be of permanent type and incorporate slide out facility for easy removal for cleaning. Power supplies shall be 100% solid state. - 5000 CFM
1190Supply, installation, testing & commissioning of Direct Driven centrifugal Exhaust air blower of following capacities. These fans shall be working on 3-ph 960RPM motor & backward curved impeller. The motor and impeller assembly shall be dynamically balanced by according to VDI 2060 with quality 2.5. The outlet duct shall be connected with a flexible canvas and outlet duct to have vent with weld mesh, fan should be complete with all accessories, rubber dampers, etc - 5000 CFM/ 50 mm static pressure
1191Supply,Installation, testing & commissioning of In-Line / Cabinet fan with 20 micron Washable filter for Fresh air Fan only, complete with Fire retardant Canvass connection and required accessories .The fan Capacity should be as under; (Fan Static Pressure-50 Pascal) - 1400 CFM
1192Supply,Installation, testing & commissioning of In-Line / Cabinet fan with 20 micron Washable filter for Fresh air Fan only, complete with Fire retardant Canvass connection and required accessories .The fan Capacity should be as under; (Fan Static Pressure-50 Pascal) - 900 CFM
1193Supply,Installation, testing & commissioning of In-Line / Cabinet fan with 20 micron Washable filter for Fresh air Fan only, complete with Fire retardant Canvass connection and required accessories .The fan Capacity should be as under; (Fan Static Pressure-50 Pascal) - 600 CFM
1194Supply,Installation, testing & commissioning of In-Line / Cabinet fan with 20 micron Washable filter for Fresh air Fan only, complete with Fire retardant Canvass connection and required accessories .The fan Capacity should be as under; (Fan Static Pressure-50 Pascal) - 400 CFM
1195Supply, Installation, Testing & Commissioning of Smoke Spill Tube Axial Fans along with motor, Baseframe, anciallary structurerequired to fix in masonary/RCC walls, connection flanges. Fans shall be direct driven not exceeding 960 RPM. Entire Fan assembly shall be rated for 300 deg.c for 2 hours. Fan Assembly certified as per the AMCA 210 air performance and AMCA 300 for sound performance. Fans shall be selected and installed to have noise level not more than 80 DBa. Motor shall be TEFC class H insulation, IP 55 protection suitable all weather application inlcuding the smoke extracts and shall be VFD Compatible. All the hardwares shall be hot dip galvanised. Fans supplied shall be capable of working on PLC control for operation during normal ventilation and fire/smoke extraction mode. - 24000 CFM @ 20 mm Of W.C TSP
1196Supply, Installation, Testing & Commissioning of Smoke Spill Tube Axial Fans along with motor, Baseframe, anciallary structurerequired to fix in masonary/RCC walls, connection flanges. Fans shall be direct driven not exceeding 960 RPM. Entire Fan assembly shall be rated for 300 deg.c for 2 hours. Fan Assembly certified as per the AMCA 210 air performance and AMCA 300 for sound performance. Fans shall be selected and installed to have noise level not more than 80 DBa. Motor shall be TEFC class H insulation, IP 55 protection suitable all weather application inlcuding the smoke extracts and shall be VFD Compatible. All the hardwares shall be hot dip galvanised. Fans supplied shall be capable of working on PLC control for operation during normal ventilation and fire/smoke extraction mode. - 22000 CFM @ 20 mm Of W.C TSP
1197Supply, Installation, Testing & Commissioning of Smoke Spill Tube Axial Fans along with motor, Baseframe, anciallary structurerequired to fix in masonary/RCC walls, connection flanges. Fans shall be direct driven not exceeding 960 RPM. Entire Fan assembly shall be rated for 300 deg.c for 2 hours. Fan Assembly certified as per the AMCA 210 air performance and AMCA 300 for sound performance. Fans shall be selected and installed to have noise level not more than 80 DBa. Motor shall be TEFC class H insulation, IP 55 protection suitable all weather application inlcuding the smoke extracts and shall be VFD Compatible. All the hardwares shall be hot dip galvanised. Fans supplied shall be capable of working on PLC control for operation during normal ventilation and fire/smoke extraction mode. - 37000 CFM @ 25 mm Of W.C TSP
1198Supply,Installation, testing & commissioning of Dual Speed Induction Centrifugal type Jet Fan suitable for standard temperature applications (CO exhaust) as well as for 300 Deg C high temperature applications (smoke exhaust 300°C/2h). The high temperature certification of fans should be in accordance with a latest version of EN 12101-3: 2015. The motor shall run on the electrical power suitable for 50Hz. The motor shall be dual speed, IP 55, Class-H certified for 300°C/2h. The fans should have protection guards at inlet & outlet side.The complete assembly must have certificate of consistency of performance by BSI and must bear CE marking. Motor make shall be the same as mentioned in the CE certificate for the Jet Fans. - Operating Fan - Coverage area - 400 Sq.M.
1199The specific aim of the CFD is to find the optimal locations, number & configuration of the Jet fans required for the ventilation of the car parking lot, for the given positions of inlets and exhaust, and given configuration of the exhaust & fresh air fans, such that it meets requirements of CO exposure limit set by health and safety regulations(FOR BASEMENT)
1200Supply, Installation, Testing & Commissioning of CO sensor (Analog).The CO level will be adjusted as per requirement. The CO level should be (Off Mode – 0 – 30 PPM, Normal Mode – 30 – 50 PPM, Fire Mode – 50 – 150 PPM )
1201Supply, installation, testing and commissioning of Tube/Vane Axial Flow type for fresh air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor IE-3 and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply, Suitable capacity of TP isolator within M.S enclosure box with suitable length of Fire Survival (LPCB approved) cable for connection with fan from isolator complete as required shall be done by contractor. Fans should be AMCA certified for air and sound performance & should be statically & dynamically balanced upto G 2.5 as per ISO 1940 & AMCA 204/3 standard. Entire fan model and AMCA seal shall appear in technical submittal of fan. The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan should be complete with all accessories including fire rated canvas connection with metallic flange, vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should not be less than 70%. ( Staircase Pressurization fan shall be interconnected with Fire alarm panel) Installtion shall be inclusive of MS base frame as per site requirements. - 24000 CFM @ 20 mm Of W.C TSP
1202Supply, installation, testing and commissioning of Tube/Vane Axial Flow type for fresh air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor IE-3 and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply, Suitable capacity of TP isolator within M.S enclosure box with suitable length of Fire Survival (LPCB approved) cable for connection with fan from isolator complete as required shall be done by contractor. Fans should be AMCA certified for air and sound performance & should be statically & dynamically balanced upto G 2.5 as per ISO 1940 & AMCA 204/3 standard. Entire fan model and AMCA seal shall appear in technical submittal of fan. The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan should be complete with all accessories including fire rated canvas connection with metallic flange, vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should not be less than 70%. ( Staircase Pressurization fan shall be interconnected with Fire alarm panel) Installtion shall be inclusive of MS base frame as per site requirements. - 22000 CFM @ 20 mm Of W.C TSP
1203Supply, installation, testing and commissioning of Tube/Vane Axial Flow type for fresh air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor IE-3 and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply, Suitable capacity of TP isolator within M.S enclosure box with suitable length of Fire Survival (LPCB approved) cable for connection with fan from isolator complete as required shall be done by contractor. Fans should be AMCA certified for air and sound performance & should be statically & dynamically balanced upto G 2.5 as per ISO 1940 & AMCA 204/3 standard. Entire fan model and AMCA seal shall appear in technical submittal of fan. The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan should be complete with all accessories including fire rated canvas connection with metallic flange, vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should not be less than 70%. ( Staircase Pressurization fan shall be interconnected with Fire alarm panel) Installtion shall be inclusive of MS base frame as per site requirements. - 18000 CFM @ 20 mm Of W.C TSP
1204Supply, installation, testing and commissioning of Tube/Vane Axial Flow type for fresh air fan of suitable capacity with powder coated MS/GSS casing and aluminium alloy impellers with high efficiency aero-foil sections, blades, the impeller directly driven by TEFC induction motor IE-3 and ‘F’ class insulation suitable for 3 Phase, 50 Hz, 415±10% Volt, ac supply, Suitable capacity of TP isolator within M.S enclosure box with suitable length of Fire Survival (LPCB approved) cable for connection with fan from isolator complete as required shall be done by contractor. Fans should be AMCA certified for air and sound performance & should be statically & dynamically balanced upto G 2.5 as per ISO 1940 & AMCA 204/3 standard. Entire fan model and AMCA seal shall appear in technical submittal of fan. The sound pressure should not exceed 80 db(A) at a distance of 3 Mts. Fan should be complete with all accessories including fire rated canvas connection with metallic flange, vibration isolators, gravity louvers, bird screen as specified in the specification. Fan total efficiency should not be less than 70%. ( Staircase Pressurization fan shall be interconnected with Fire alarm panel) Installtion shall be inclusive of MS base frame as per site requirements. - 37000 CFM @ 25 mm Of W.C TSP
1205Supply,Installation, testing & commissioning of GI Ducting Factory Fabricated with TDF Flanges as per SMACNA. The cost shall include Primary as well as secondary supports. Also all the ducting joints shall be completely sealed with Silicon Sealant, and a leak proof system shall be provided. All supports shall be in G.I. - 2250 mm & Above - 18 guage
1206Supply,Installation, testing & commissioning of GI Ducting Factory Fabricated with TDF Flanges as per SMACNA. The cost shall include Primary as well as secondary supports. Also all the ducting joints shall be completely sealed with Silicon Sealant, and a leak proof system shall be provided. All supports shall be in G.I. - 1500 mm to 2250mm - 20 guage
1207Supply,Installation, testing & commissioning of GI Ducting Factory Fabricated with TDF Flanges as per SMACNA. The cost shall include Primary as well as secondary supports. Also all the ducting joints shall be completely sealed with Silicon Sealant, and a leak proof system shall be provided. All supports shall be in G.I. - 750 mm to 1500 mm-22 guage
1208Supply,Installation, testing & commissioning of GI Ducting Factory Fabricated with TDF Flanges as per SMACNA. The cost shall include Primary as well as secondary supports. Also all the ducting joints shall be completely sealed with Silicon Sealant, and a leak proof system shall be provided. All supports shall be in G.I. - 0 mm to 750 mm - 24 guage
1209Supply,Installation, testing & commissioning Non Insulated Flexible duct of the following diameter: 100mm Dia.
1210Supply,Installation, testing & commissioning Non Insulated Flexible duct of the following diameter: 150mm Dia.
1211Supplying and erecting iron work, sheet metal work consisting of MS sheets,various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc.for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer.
1212Providing adhesive thermal insulation for supply return air duct with 19mm nitrile rubber insulation having R-value as per the prevailing provisions in ECBC-2007.
1213Supply,Installation, testing & commissioning of Acoustic insulation of duct with 10mm thick Armasound (Nitrile Rubber) Insulation Material stuck to the duct using Adhesive and then mechanically fixing to the duct using GI Nuts & Bolts and sealant to seal the leakages.
1214Supply, Installation, Testing & Commissioning of Thermal Insulation for External ducting with 32mm thick XLPE / Nitrile Rubber Class 'O' for Fire with adhesive and all the joints sealed & finished with Alu Tape. The insulation shall have factory pasted wrinkled Aluminium Foil finish / UV Stabilised Finish and finally finished with 26 Gauge Aluminium Cladding.
1215Supply,Installation, testing & commissioning of Underdeck Roof insulation with 32 mm thick Nitrile Rubber / XLPE Class \\"O\\" for fire, Fixed to the underside of the slab. The slab surface shall be thoroughly cleaned, and adhesive applied to the slab surface and the insulation material, the insulation shall be fixed at 2ft x 2ft grid of self tapping screws. The Insulation shall be temporarily Held by means of adhesive, and reinforce the insulation with GI Lacing wire.
1216Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete.
1217Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete.
1218Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supply, Installation, Testing and Commissioning of AL powder coated square type supply air diffuser with damper, Outer size-600X600 and Neck size-400X400
1219Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supply, Installation, Testing and Commissioning of AL powder coated square type Return air diffuser without damper, Outer size-600X600 and Neck size-600X600
1220Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supplying and erecting aluminium powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45 degree.
1221Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supplying and installing of coller damper of galvanised iron material of upto 120 microns for anti corrosive resistance for supply air grill of required size
1222Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Aluminium Powder Coated Weather Louver for fresh and Exhaust Air for Ventilation Fans
1223Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - GI Duct Type Fire Damper with Geared Mechanism for Control. The Damper shall be rated for 90 minutes rating. The damper shall be fusible link type
1224Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - GI Duct Type Fire Damper with Geared Mechanism for Control. The Damper shall be rated for 90 minutes rating. The damper shall have provision of fixing a Actuator.
1225Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Actuators for Fire Dampers, complete with Sensors, Control Panel, and suitable for operation of 220 V AC Supply.
1226Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. -Aluminum powdered coated door transfer non vision grille for toilet area
1227Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supply, installation, testing & commissioning of aluminium powder coated Jet Diffusers with damper of 400mm Dia. Suitable for Throw 15m.
1228Supply,Installation, testing & commissioning of Air Distribution Products of the following types complete with all accessories mentioned With all fittings for installation in GI. - Supply, installation, testing and commissioning of disc valves suitable for exhausting toilet foul air ,comprising of an adjustable centre cone and coupling sleeve made of Aluminum sheet duly epoxy painted with approved color. The disc valve shall be fitted with a galvanised steel installation frame and the sleeve shall incorporate a foam-rubber gasket for airtight sealing. The centre cone should be adjustable for balancing and with a locking arrangement to maintain the desired flow rate. - Dia.150mm
1229Supply,Installation, testing & commissioning of Busbar Box for chillers Complete with Aluminium busbar, IP44 Protection (Indoor Use), RAL7035 Shade. This Box is used in between chiller main panel and chiller.
1230Supply,Installation, testing & commissioning of Main Panel for 1 Incoming Feeder with ACB and Outgoing Feeder 17 Nos. 3 Nos for Chiller(2W+1S), 3 Nos. For Condenser Water Pumps (2W+1S), 6 Nos. (2 Nos. Fans for each Tower) for Cooling Towers (2W+1S), 3 Nos. For Primary Pumps (2W+1S), 2 No. Vacant (Spare), Suitable rating MCB Compartment for Motorised Butterfly Valves, ATCS,Pressurisation pumps,Dscal Microprocessor Spare etc.The Panel shall be IP - 44 Protection for Indoor use complete with Panel Intelligent meter, R-Y-B indication Lights, Control Fuses & Copper tinted Bus Bar. All Pump Feeders complete with Star Delta Starters, MPCB Push Buttons indication ON/OFF / Trip lights etc. VFDs with by-pass arrangement to be provided for 3 Nos. For Primary Pumps (2W+1S),3 Nos. Common VFD for Cooling tower fan. Contactor to be added for the VFDs. For 15kW & above motors, digital CT operated ammmeter shall be provided.Panel should also be complete with 230 V Supply for 1 No. BMS Panel, 230 V AC Switch Socket as spare. Panel shall be BMS Compatible for Hard & VFD Soft Points.
1231Supply,Installation, testing & commissioning of AHU Feeder Panel of Convension Hall AHU's for 1 Incoming Feeder with MCB/MCCB and Ou.The Panel shall be IP - 44 Protection for Indoor use complete with Panel Intelligent meter, R-Y-B indication Lights, Control Fuses & Copper tinted Bus Bar. All Pump Feeders complete with Star Delta Starters, MPCB Push Buttons indication ON/OFF / Trip lights etc. Contactor to be added for the VFDs. For 15kW & above motors, digital CT operated ammmeter shall be provided. tgoing Feeder 5 Nos. 2 Nos for 15000 CFM AHU, 1 Nos for 11000 CFM AHU, 2 No. Vacant (Spare). Panel should also be complete with 230 V Supply for 1 No. BMS Panel, 230 V AC Switch Socket as spare. Panel shall be BMS Compatible for Hard & VFD Soft Points.
1232Supply,Installation, testing & commissioning of AHU Feeder Panel of Ground to fifth floor Lobbies AHU's for 1 Incoming Feeder with MCB/MCCB and Outgoing Feeder 3 Nos. 3 Nos for 27000 CFM AHU, 2 No. Vacant (Spare). The Panel shall be IP - 65 Protection for Outdoor use complete with Panel Intelligent meter, R-Y-B indication Lights, Control Fuses & Copper tinted Bus Bar. All Pump Feeders complete with Star Delta Starters, MPCB Push Buttons indication ON/OFF / Trip lights etc. Contactor to be added for the VFDs. For 15kW & above motors, digital CT operated ammmeter shall be provided. Panel should also be complete with 230 V Supply for 1 No. BMS Panel, 230 V AC Switch Socket as spare. Panel shall be BMS Compatible for Hard & VFD Soft Points.
1233Supply,Installation, testing & commissioning of AHU Feeder Panel of Auditorium AHU's for 1 Incoming Feeder with MCB/MCCB and Outgoing Feeder 7 Nos. 2 Nos for 27000 CFM AHU, 2 Nos for 23000 CFM AHU,1 Nos for 6000 CFM AHU, 2 No. Vacant (Spare).The Panel shall be IP - 44 Protection for Indoor use complete with Panel Intelligent meter, R-Y-B indication Lights, Control Fuses & Copper tinted Bus Bar. All Pump Feeders complete with Star Delta Starters, MPCB Push Buttons indication ON/OFF / Trip lights etc. Contactor to be added for the VFDs. For 15kW & above motors, digital CT operated ammmeter shall be provided. Panel should also be complete with 230 V Supply for 1 No. BMS Panel, 230 V AC Switch Socket as spare. Panel shall be BMS Compatible for Hard & VFD Soft Points.
1234Supply,Installation, testing & commissioning of Indivisual AHU Panel with 1 No. Incoming Feeder with MCCB and 2 Nos. Outgoing Feeders, 1 Nos. for Supply air fan with Common VFD's and By-Pass Arrangement. 1 No. Vacant compartment to be provided as spare.AHU Feeder compartment should be complete with DOL / Star Delta starter for motors with VFD and By-Pass arrangement, MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking. The Panel shall be complete with Panel Intelligent meter, R-Y-B indication Light, Control Fuses & Copper tinted Bus Bar. The Panel shall also be complete with 2 Nos. 230 V AC Supply 1 No. for BMS Panel, 1 No. for Light Limit Switch, 24 V AC Supply for 2 Way PIBCV Valve Actuator, 3 Way Valve Hot water, Provision for fitting Combo Display Unit etc. 1 No. 230 V AC Switch Socket should also be included in the Panel. Panel shall be BMS Compatible for Hard & Soft Points. For 15kW & above motors, digital CT operated ammmeter shall be provided.- 27000 cfm - (IP - 65 Protection for Outdoor use)
1235Supply,Installation, testing & commissioning of Indivisual AHU Panel with 1 No. Incoming Feeder with MCCB and 2 Nos. Outgoing Feeders, 1 Nos. for Supply air fan with Common VFD's and By-Pass Arrangement. 1 No. Vacant compartment to be provided as spare.AHU Feeder compartment should be complete with DOL / Star Delta starter for motors with VFD and By-Pass arrangement, MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking. The Panel shall be complete with Panel Intelligent meter, R-Y-B indication Light, Control Fuses & Copper tinted Bus Bar. The Panel shall also be complete with 2 Nos. 230 V AC Supply 1 No. for BMS Panel, 1 No. for Light Limit Switch, 24 V AC Supply for 2 Way PIBCV Valve Actuator, 3 Way Valve Hot water, Provision for fitting Combo Display Unit etc. 1 No. 230 V AC Switch Socket should also be included in the Panel. Panel shall be BMS Compatible for Hard & Soft Points. For 15kW & above motors, digital CT operated ammmeter shall be provided.- 23000 cfm - (IP - 44 Protection for Indoor use)
1236Supply,Installation, testing & commissioning of Indivisual AHU Panel with 1 No. Incoming Feeder with MCCB and 2 Nos. Outgoing Feeders, 1 Nos. for Supply air fan with Common VFD's and By-Pass Arrangement. 1 No. Vacant compartment to be provided as spare.AHU Feeder compartment should be complete with DOL / Star Delta starter for motors with VFD and By-Pass arrangement, MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking. The Panel shall be complete with Panel Intelligent meter, R-Y-B indication Light, Control Fuses & Copper tinted Bus Bar. The Panel shall also be complete with 2 Nos. 230 V AC Supply 1 No. for BMS Panel, 1 No. for Light Limit Switch, 24 V AC Supply for 2 Way PIBCV Valve Actuator, 3 Way Valve Hot water, Provision for fitting Combo Display Unit etc. 1 No. 230 V AC Switch Socket should also be included in the Panel. Panel shall be BMS Compatible for Hard & Soft Points. For 15kW & above motors, digital CT operated ammmeter shall be provided.- 15000 cfm - (IP - 44 Protection for Indoor use)
1237Supply,Installation, testing & commissioning of Indivisual AHU Panel with 1 No. Incoming Feeder with MCCB and 2 Nos. Outgoing Feeders, 1 Nos. for Supply air fan with Common VFD's and By-Pass Arrangement. 1 No. Vacant compartment to be provided as spare.AHU Feeder compartment should be complete with DOL / Star Delta starter for motors with VFD and By-Pass arrangement, MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking. The Panel shall be complete with Panel Intelligent meter, R-Y-B indication Light, Control Fuses & Copper tinted Bus Bar. The Panel shall also be complete with 2 Nos. 230 V AC Supply 1 No. for BMS Panel, 1 No. for Light Limit Switch, 24 V AC Supply for 2 Way PIBCV Valve Actuator, 3 Way Valve Hot water, Provision for fitting Combo Display Unit etc. 1 No. 230 V AC Switch Socket should also be included in the Panel. Panel shall be BMS Compatible for Hard & Soft Points. For 15kW & above motors, digital CT operated ammmeter shall be provided.- 11000 cfm - (IP - 44 Protection for Indoor use)
1238Supply,Installation, testing & commissioning of Indivisual AHU Panel with 1 No. Incoming Feeder with MCCB and 2 Nos. Outgoing Feeders, 1 Nos. for Supply air fan with Common VFD's and By-Pass Arrangement. 1 No. Vacant compartment to be provided as spare.AHU Feeder compartment should be complete with DOL / Star Delta starter for motors with VFD and By-Pass arrangement, MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking. The Panel shall be complete with Panel Intelligent meter, R-Y-B indication Light, Control Fuses & Copper tinted Bus Bar. The Panel shall also be complete with 2 Nos. 230 V AC Supply 1 No. for BMS Panel, 1 No. for Light Limit Switch, 24 V AC Supply for 2 Way PIBCV Valve Actuator, 3 Way Valve Hot water, Provision for fitting Combo Display Unit etc. 1 No. 230 V AC Switch Socket should also be included in the Panel. Panel shall be BMS Compatible for Hard & Soft Points. For 15kW & above motors, digital CT operated ammmeter shall be provided.- 6000 cfm - (IP - 65 Protection for Outdoor use)
1239Supply, Installation, Testing & Commissioning of Electrical Starter Panel for the Ventilation Fans, complete with DOL/ Star Delta Starter, Indicating Lamps, ON/OFF Switch, Ammeter etc., The Panel shall be IP - 44 Protection for Indoor use. - Cabinet Fan - 4000 CFM
1240Supply, Installation, Testing & Commissioning of Electrical Starter Panel for the Ventilation Fans, complete with DOL/ Star Delta Starter, Indicating Lamps, ON/OFF Switch, Ammeter etc., The Panel shall be IP - 44 Protection for Indoor use. - Kitchen Blower & Dry Scrubber - 5000 CFM
1241Supply,Installation, testing & commissioning of Starter Panel for the Smoke venting fans with Star Delta / DOL starter with MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking with Fire Panel to enable automatic start in case of fire including with PLC control panel, wall mounted, with SMPS power pack 230 V AC/24 DC-3.2 A for CO sensor+ PLC, With PS/CPU/Memory module+8 channel with Digital output card,1no. 4 channel analaogue input module, , 8 channel relay card complete with programming ladder diagram + 0-50ppm alarm setting & 50-100 ppm fan actuation,field trial. (Deltacorp/Phoenix Kontact /Siemens/LnT)The Panel shall be IP - 44 Protection for Indoor use. - 1 Incoming & 6 Outgoing feeders for 4 Nos. Tube Axial Exhaust Fans ,4 Nos. Tube Axial Fresh Air Fans, 9 Nos. Jet Fans
1242Supply,Installation, testing & commissioning of Starter Panel for the Smoke venting fans with Star Delta / DOL starter with MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking with Fire Panel to enable automatic start in case of fire including with PLC control panel, wall mounted, with SMPS power pack 230 V AC/24 DC-3.2 A for CO sensor+ PLC, With PS/CPU/Memory module+8 channel with Digital output card,1no. 4 channel analaogue input module, , 8 channel relay card complete with programming ladder diagram + 0-50ppm alarm setting & 50-100 ppm fan actuation,field trial. (Deltacorp/Phoenix Kontact /Siemens/LnT)The Panel shall be IP - 44 Protection for Indoor use. - 1 Incoming & 6 Outgoing feeders for 4 Nos. Tube Axial Exhaust Fans ,4 Nos. Tube Axial Fresh Air Fans, 9 Nos. Jet Fans
1243Supply,Installation, testing & commissioning of Starter Panel for the Smoke venting fans with Star Delta / DOL starter with MPCB Push Buttons ON/OFF Trip Indication lights etc., with necessary interlocking with Fire Panel to enable automatic start in case of fire including with PLC control panel, wall mounted, with SMPS power pack 230 V AC/24 DC-3.2 A for CO sensor+ PLC, With PS/CPU/Memory module+8 channel with Digital output card,1no. 4 channel analaogue input module, , 8 channel relay card complete with programming ladder diagram + 0-50ppm alarm setting & 50-100 ppm fan actuation,field trial. (Deltacorp/Phoenix Kontact /Siemens/LnT)The Panel shall be IP - 44 Protection for Indoor use. - 1 Incoming & 6 Outgoing feeders for 4 Nos. Tube Axial Exhaust Fans ,4 Nos. Tube Axial Fresh Air Fans, 9 Nos. Jet Fans
1244Supply,Installation, testing & commissioning of PLC Panel for Auditorium Fresh air & smoke exhaust system. Panel shall be interlocked with Motorised fire damper & tube axial fan. Operation of fire dampers shall be in scope of work.
1245Supply, Installation, Testing & Commissioning of Sequential Controller for operation of working & standby machines in 24 x 7 operation mode for 1 working & 1 standby Machines.
1246Supply, Installation , Testing & Comissioning of suitable size PVC Copper Armoured Electrical cables from Main Electrical Panel to Individual Equipments.Cable Size shall be as per OEM requirement. Cables shall be required for Main Electrical panels to Chillers, Primary Pumps, Condenser Pumps, Cooling Tower fans, ATCS System, D'scall Microprocessor, Motorised Valves,etc
1247Supply, Installation , Testing & Comissioning of suitable size PVC Copper Armoured Electrical cables from AHU VFD Panel to Individual AHU's fan Motors- 27000 CFM X 5 No's,23000 CFM X 2 No's, 15000 CFM X 4 No's, 11000 CFM X 2 No's, 6000 CFM X 1 No's.Cable Size shall be as per OEM requirement.Cost Shall be Inculding with cabling for Light limit switch, 2 way valves,etc.
1248Supply, Installation , Testing & Comissioning of suitable size PVC Copper Armoured Electrical cables from Electrical Panel to ventilation Fans- CABINET FRESH AIR FAN-4000 CFM -2 Nos,Kitchen Exhaust Blower-5000 CFM -2 Nos,Kitchen Dry Scrubber-5000 CFM -2 Nos,24000 CFM Tube axial exhaust fan-4 Nos,24000 CFM Tube axial Fresh air fan-4 Nos,22000 CFM Tube axial exhaust fan-2 Nos,22000 CFM Tube axial Fresh air fan-2 Nos, Jet Fans-27 Nos & CO Sensors-27 Nos.
1249Supply, Installation , Testing & Comissioning of suitable size PVC Copper Armoured Electrical cables from AHU Feeder Panel to Individual AHU VFD Panels- For Convension hall AHU's, Auditorium AHU's & Ground to fifth floor lobbies AHU's
1250Supply,Installation, testing & commissioning of of Power Cabling between DX Indoor Unit & Supply Point near the indoor unit. The power cable used shall be as per manufacturer recommendation with Flexible PVC Conduit and Pin Top.
1251Supply,Installation, testing & commissioning of of Power Cabling for chilled water indoor unit.The power cable used shall be as per manufacturer recommendation with Flexible PVC Conduit and Pin Top.
1252Supply,Installation, testing & commissioning of of Power Cabling for Inline fans. The power cable used shall be as per manufacturer recommendation with Flexible PVC Conduit and Pin Top.
1253Cabling required for sequence Controller for Working and standby DX Units.
1254Supply , Installation, Testing and Commissioning of 4 Core 1.5 sq mm shielded unarmoured ATC conductor multistranded twisted, overall PVC sheathed mylar tapped signal cable, including all accessories
1255Supply , Installation, Testing and Commissioning of 2 Core 1.5 sq mm shielded unarmoured ATC conductor multistranded twisted, overall PVC sheathed mylar tapped signal cable, including all accessories
1256Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -50 X 6 GI Strip
1257Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -25 X 6 GI Strip
1258Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -25 X 3 GI Strip
1259Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -1C x 1.5 Sqmm - Yellow Bar Green Cable
1260Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -1C x 2.5 Sqmm - Yellow Bar Green Cable
1261Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -1C x 4 Sqmm - Yellow Bar Green Cable
1262Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -1C x 6 Sqmm - Yellow Bar Green Cable
1263Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -1C x 10 Sqmm - Yellow Bar Green Cable
1264Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -1C x 16 Sqmm - Yellow Bar Green Cable
1265Supply, Installation, Testing & comissioning of Earthing for all above equipment as per following; -1C x 25 Sqmm - Yellow Bar Green Cable
1266Supply, Installation , Testing & comissioning of 14G Perforated cable tray, duly galvanised with necessary supporting members for suspension to slab / wall supporting with final finishing. All the Cable trays shall be provided with GI Cover. - Perforated Type - 600 mm x 50 mm
1267Supply, Installation , Testing & comissioning of 14G Perforated cable tray, duly galvanised with necessary supporting members for suspension to slab / wall supporting with final finishing. All the Cable trays shall be provided with GI Cover. - Perforated Type - 450 mm x 50 mm
1268Supply, Installation , Testing & comissioning of 14G Perforated cable tray, duly galvanised with necessary supporting members for suspension to slab / wall supporting with final finishing. All the Cable trays shall be provided with GI Cover. - Perforated Type - 300 mm x 50 mm
1269Supply, Installation , Testing & comissioning of 14G Perforated cable tray, duly galvanised with necessary supporting members for suspension to slab / wall supporting with final finishing. All the Cable trays shall be provided with GI Cover. - Perforated Type - 200 mm x 50 mm
1270Supply, Installation , Testing & comissioning of 14G Perforated cable tray, duly galvanised with necessary supporting members for suspension to slab / wall supporting with final finishing. All the Cable trays shall be provided with GI Cover. - Perforated Type - 150 mm x 50 mm
1271Supply, Installation , Testing & comissioning of 14G Perforated cable tray, duly galvanised with necessary supporting members for suspension to slab / wall supporting with final finishing. All the Cable trays shall be provided with GI Cover. - Perforated Type - 100 mm x 50 mm
1272Supply, Installation , Testing & comissioning of 14G Perforated cable tray, duly galvanised with necessary supporting members for suspension to slab / wall supporting with final finishing. All the Cable trays shall be provided with GI Cover. - Perforated Type - 50 mm x 50 mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57501284
AUTHORITY Local Bodies
TENDER VALUE 196.38 Crore
LAST DATE 05-10-2026
Authority
Authority Name Thane Municipal Corporation
Work Description Tender for Construction And Interior Work For Nirupankar Tirtharup Appasaheb Dharmadhikari Auditorium On An Amenity Plot At Waghbil Within The Thane Municipal Corporation Area.
Basic Detail
Tender No TMC/PRO/PWD-HO/475/2026-27
Bidding Type Tender
Location
City Thane
State Maharashtra
Key Dates
Publish Date 12 Sep 2026
Submission Date 05 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 196.38 Crore
Tender Fee 11800
EMD 98.19 Lakhs
Exemption Not Available
Document List
baa78a05-1608-4401-add0-152062183046.html
BOQ_2288283.xls
TD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

baa78a05-1608-4401-add0-152062183046.html

xls

BOQ_2288283.xls

pdf

TD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders