Tender For Repair/ Maintenance To Lt Ug Cable, Lt Panel, Apfc Panel Etc. And Preventive Maintenance To External Services At Nofra, Nad And maintenance of Goa Under Ge Gomantak Vasco
Tender Value
45 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
13 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance To Lt Ug Cable, Lt Panel, Apfc Panel Etc. And Preventive Maintenance To External Services At Nofra, Nad And maintenance of Goa Under Ge Gomantak Vasco
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in hard/dense soil for foundation, etc. or for laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed. |
| 2 | Excavation in trenches in soft/disintegrated rock, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed. |
| 3 | Returning filling in including spreading watering and well raming in layer excedding 25 cm each in any type of soil/rock complete all as specified and directed. |
| 4 | Removing excavated material (Soils/rock) to a distance not exceeding 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with Aluminium busbar TPN 400 Amp. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-INCOMING MCCBa) 320 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 01 Nos.OUTGOING MCCBa) 100 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 04 Nos. b) CT of suitable ratio 400/5 Amp - Set of 03 Nosc) Space for spare MCCB/MCBMetering:a) Multi function digital meter (VAF & PF) -01 No.b) LED Indicating lamps RYB set of three -01 SetsNote :- (i) The manufacture shall submit a copy of TESTREPORT of CPRI approved.(ii) All MCCBs shall be terminal spreader and extended rotary operating mechanism.(iii) All MCCBs shall be compartmentalized and provided separate ON/OFF indicator lamps (green & red) |
| 6 | Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with Aluminium busbar TPN 400 Amp. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-INCOMING MCCBa) 250 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 01 Nos.OUTGOING MCCBa) 100 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 04 Nos. b) CT of suitable ratio 250/5 Amp - Set of 03 Nosc) Space for spare MCCB/MCBMetering:a) Multi function digital meter (VAF & PF) -01 No.b) LED Indicating lamps RYB set of three -01 SetsNote :- (i) The manufacture shall submit a copy of TESTREPORT of CPRI approved.(ii) All MCCBs shall be terminal spreader and extended rotary operating mechanism.(iii) All MCCBs shall be compartmentalized and provided separate ON/OFF indicator lamps (green & red) |
| 7 | Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with Aluminium busbar TPN 400 Amp. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-INCOMING MCCBa) 250 Amp 4 pole MCCB 36 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 01 Nos.OUTGOING MCCBa) 100 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 04 Nos. b) CT of suitable ratio 250/5 Amp - Set of 03 Nosc) Space for spare MCCB/MCBMetering:a) Multi function digital meter (VAF & PF) -01 No.b) LED Indicating lamps RYB set of three -01 SetsNote :- (i) The manufacture shall submit a copy of TESTREPORT of CPRI approved.(ii) All MCCBs shall be terminal spreader and extended rotary operating mechanism.(iii) All MCCBs shall be compartmentalized and provided separate ON/OFF indicator lamps (green & red) |
| 8 | M&L for repairing to LT panel board of different sizes by dismantling damaged and rusted portions, cutting straightening and welding of rusted/ deformed CRCA/ MS sheet, MS angle supports etc., repairing door hinges, locks, gland plates, Panel base frame supports and partitions, grindig and finishing welded joints and preparation of surface by removing all dirt, dust, making necessary and painting complete surface including connected accessories with one coat of anti rust primer and two coats of synthetic enamel paint of approved colour including writing of identification etc. all as directed. |
| 9 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sqmm 4 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 10 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 35 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 11 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 50 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 12 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 70 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 13 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 95 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 14 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 120 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 15 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 185 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 16 | S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 240 Sqmm 3.5 core including gland, lugs etc. laid in trenches or fixed on wall/floor/poles complete all as specified and directed. |
| 17 | M&L for replacement of GI tubing medium grade 80 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed . |
| 18 | Supply & laying in replacement double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed. |
| 19 | Supply & laying in replacement double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 75 mm inner dia and 90 mm outer dia complete all as directed. |
| 20 | Supply & laying in replacement double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 94 mm inner dia and 110 mm outer dia complete all as directed. |
| 21 | S&F in replacement of existing unsv cable joints with straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 50 sqmm, 1100 V and testing after jointing complete all as directed. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint. |
| 22 | S&F in replacement of existing unsv cable joints with straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to 120 sqmm, 1100 V and testing after jointing complete all as directed. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint. |
| 23 | S&F in replacement of existing unsv cable joints with straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 240 sqmm,1100 V and testing after jointing complete all as directed. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint. |
| 24 | S&F in replacement MCCB 63 Amps, 415 volts, 50 Hz, 4 pole, 16 KA breaking capacity with thermal magnetic setting including providing suitable size aluminium lugs, speders complete all as specified and directed. |
| 25 | S&F in replacement MCCB 100 Amps, 415 volts, 50 Hz, 4 pole, 16 KA breaking capacity with thermal magnetic setting including providing suitable size aluminium lugs, speders complete all as specified and directed. |
| 26 | S&F in replacement MCCB 160 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed. |
| 27 | S&F in replacement MCCB 250 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed. |
| 28 | S&F in replacement MCCB 400 Amps 415 volts, 4 pole, 36 KA breaking capacity with thermal magnetic setting suitable for VTPN including providing suitable size aluminium lugs, spreaders complete all as specified and directed. |
| 29 | M&L for preparation of old painted surface of Feeder Pillar box/LT Panel by removing all dirt, dust, making necessary welding of broken parts etc. and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification etc all as directed |
| 30 | M & L for cutting and removing grass, vegetation, bushes etc and cleaning the installation and surroundings complete for a substation/ installation all as specified and directed |
| 31 | M&L for PCC 1:3:6 type C-1 ( using 20 mm graded stone aggregate) as in repair of earth pit, cable duct, PCC near GOD and transformer including necessary formwork complete all as specified and directed. |
| 32 | M & L for filling and spreading aggregate using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc. complete all as specified and directed. |
| 33 | M&L taking out old earthing and providing new earthing complete with galvanised steel plate electrode 600 mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and earth strip upto 7.5 M. |
| 34 | S&F in replacement aluminium lugs suitable for cable size 6 Sqmm 2/3/3.5/4 core complete all as specified and directed. |
| 35 | S&F in replacement aluminium lugs suitable for cable size 10 Sqmm 2/3/3.5/4 core complete all as specified and directed. |
| 36 | S&F in replacement aluminium lugs suitable for cable size 16 Sqmm 2/3/3.5/4 core complete all as specified and directed. |
| 37 | S&F in replacement aluminium lugs suitable for cable size 25 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 38 | S&F in replacement aluminium lugs suitable for cable size 50 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 39 | S&F in replacement aluminium lugs suitable for cable size 70 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 40 | S&F in replacement aluminium lugs suitable for cable size 95 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 41 | S&F in replacement aluminium lugs suitable for cable size 120 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 42 | S&F in replacement aluminium lugs suitable for cable size 150 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 43 | S&F in replacement aluminium lugs suitable for cable size 185 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 44 | S&F in replacement aluminium lugs suitable for cable size 240 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 45 | S&F in replacement aluminium lugs suitable for cable size 400 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 46 | S&F in replacement copper lugs suitable for cable size 95 Sqmm 3/3.5/4 core complete all as specified and directed. |
| 47 | S&F in replacement aluminium strip 25 x 3 mm fix on porcelain insulator for roof conductors and down conductors above ground level as lighting conductor (including insulator) complete all as required at site and as directed. |
| 48 | M&L taking out old earthing and providing new earthing complete with copper plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts check nuts and washers of brass connected to earthing test point all as specified incl 25 mm GI tubing medium grade and necessary fitting for protection of GI wire, laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 15 mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 5 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth strip and earh strip upto 7.5 M. |
| 49 | S&F in replacement 20 x 3 mm copper strip earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed. |
| 50 | M&L for replacement of GI tubing light grade 40 mm bore for passing copper/ aluminium strip laid under the floor, along the wall or along the pole complete all as specified and directed . |
| 51 | S&F in replacement loop-in-loop out fuse junction (SMC) box of internal dimension 250 x 200 x 100 mm made out of FRP sheet and locking screw fitted with and incl 10 Amps MCB - 1 No, 20 Amps rated 4 way connectors for 3 phase and neutral incoming/ out going, mounted in the box, fixing on any type of poles including necessary clamps, suitable glands, Connector, lugs, GI nut and bolts complete all as specified and directed.Make : Sintex/ Hensel/National |
| 52 | M&L for fixing in replacement test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hexagonal head screw and including provision of suitable MS box made out of 3 mm thick MS sheet to accommodate the terminal block complete all as specified and directed. |
| 53 | M&L for PCC 1:3:6 Type C-1 (using 20 mm graded stone aggregate) as in coping/pedestal of poles including necessary form work and finishing the surface with rendering 5 mm thick in cement mortar 1:4 finished even and smooth withot using extra cement complete all as specified and directed. |
| 54 | S&F in replacement Air termination, single pointed aluminiuim rod 12mm dia and 300 mm long complete all as specified and directed. |
| 55 | S&F in replacement APFC relay 6/8 steps, microprocessor based, 415 V complete all as directed. Make:- Schneider Cat part Varlogic RT-6 or equivalent in Havells/ L&T/Selec |
| 56 | S&F in replacement power factor correction capacitors Heavy duty for 3 phase, 440 V, 50 HZ, AC self healing metalized polypropyllene of 10 KVAR capacity suitable for APFC panel operation complete all as specified and directed.Make:- L&T Cat part MD-XL or equivalent in Havells/Schneider |
| 57 | S&F in replacement 10 KVAr capacitor duty contactor, 415 V complete all as directed. Make:- L&T Cat part MO C or equivalent in Havells/ Schneider/ Seimens |
| 58 | S&F in replacement HRC fuse base with fuse 32 A TP for 50/150 KVAr complete all as directed. Make:- L&T/ Havells/ Schneider/Seimens |
| 59 | S&F in replacement current transformer 200/5 A complete all as directed. Make:- AE/ ABB/ Schneider/ L&T |
| 60 | S&F in replacement Led type RYB indicator lamp complete all as directed. Make:- AE/ L&T/ Havells/ Teknic |
| 61 | S&F in replacement selector switch Hand-Off-Auto or Manual-Auto type complete all as directed. Make:- L&T/ Havells/ Siemens/ Schneider |
| 62 | S&F in replacement power factor correction capacitors Heavy duty for 3 phase, 440 V, 50 HZ, AC self healing metalized polypropyllene of 12.5 KVAr capacity suitable for APFC panel operation complete all as specified and directed.Make:- L&T Cat part MD-XL or equivalent in Havells/Schneider |
| 63 | S&F in replacement 12.5 KVAr capacitor duty contactor, 415 V complete all as directed. Make:- L&T Cat part MO C or equivalent in Havells/ Schneider/ Seimens |
| 64 | S&F in replacement APFC relay 12 steps, microprocessor based, 415 V complete all as directed. Make:- Schneider Cat part Varlogic RT-12 or equivalent in Havells/ L&T/Selec |
| 65 | S&F in replacement current transformer 300/5 A complete all as directed. Make:- AE/ ABB/ Schneider/ L&T |
| 66 | S&F in replacement digital voltmeter with selector switch Hand-Off-Auto or Manual-Auto type complete all as directed. Make:- AE/ L&T/ Havells/ Siemens/ Schneider |
| 67 | S&F in replacement digital Ampere meter with selector switch Hand-Off-Auto or Manual-Auto type complete all as directed. Make:- AE/ L&T/ Havells/ Siemens/ Schneider |
| 68 | S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. |
| 69 | S&F in replacement panel cooling fan, 230 V, AC, minimum air flow 120 Cum/Hr complete with filter assembly, protective grill, mounting hardware, wiring and thermostat, including all accessories and installation necessary as per existing at site complete all as directed. Make:- Rittal / Pfannenberg/ Selec/ Multispan Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender