Tender For Repair / Maintenance Of Street Lights, High/Medium Mast Lights, Solar Lights, High/Low Bay Flood Lights, Bldg Security Area, Lighting Including Its Astronomical Timer Switch And Connected Works At Tech Area Under Afs Phalodi
Tender Overview
Project Description
Tender for Repair / Maintenance Of Street Lights, High/Medium Mast Lights, Solar Lights, High/Low Bay Flood Lights, Bldg Security Area, Lighting Including Its Astronomical Timer Switch And Connected Works At Tech Area Under Afs Phalodi
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF), Air Force Station, Phalodi Name of Work : REPAIR / MAINT OF STREET LIGHTS, HIGH/MEDIUM MAST LIGHTS, SOLAR LIGHTS, HIGH/LOW BAY FLOOD LIGHTS, BLDG SECURITY AREA, LIGHTING INCLUDING ITS ASTRONOMICAL TIMER SWITCH AND CONNECTED WORKS AT TECH AREA UNDER AFS PHALODI Contract No: GE (AF) PHALODI/ OF 2026-27 Serial Page No. Bidder Name : SCHEDULE 'A'(BOQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT TEXT # NUMBER TEXT NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER NUMBER # TEXT Srl.No. Item Description Item Code / Make Approx No of Units reqd Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in Soft/ loose soil etc for laying of cable complete as specified and directed. . |
| 3 | Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified and directed. |
| 5 | Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose. |
| 6 | Supplying and laying un reinforced precast concrete cable cover Class LV, Type I, flat, size 250mm x150mm x 40mm, laid by dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cable for protection all as specified and directed. |
| 7 | Supply and laying of size 4 core 16 sqmm. XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor, 1100 volts laid in trenches, ducts, pipes, drawn across the roads/paths/drains/along poles/walls/floors/equipment etc including jointing and testing complete all as specified and directed. |
| 8 | Supply and laying of size 4 core 25 sqmm. XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor, 1100 volts laid in trenches, ducts, pipes, drawn across the roads/paths/drains/along poles/walls/floors/equipment etc including jointing and testing complete all as specified and directed. |
| 9 | Supply and laying of size 4 core 35 sqmm. XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor, 1100 volts laid in trenches, ducts, pipes, drawn across the roads/paths/drains/along poles/walls/floors/equipment etc including jointing and testing complete all as specified and directed. |
| 10 | Disconnecting and Taking out of old LT armored PVC cables from trenches of any size/core/any voltage grade from trenches for replacement complete all as specified and directed. |
| 11 | Supply and laying/ fixing in replacement of GI tube, light grade, 40mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light polesor as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. |
| 12 | M & L replacement for PVC insulated and sheathed weather proof two core 6 sqmm single stranded aluminium conductor service cable for connection all complete as specified and directed incl taking down UNSV cable. |
| 13 | M & L replacement for PVC insulated and sheathed weather proof two core 10 sqmm single stranded aluminium conductor service cable for connection all complete as specified and directed incl taking down UNSV cable. |
| 14 | Supply and fixing in replacement of unserviceable garden lights with LED landscape luminaires 10 Watts pressure die cast powder coated housing with PC diffuser,Efficient high output COB for garden, Pathway lightning, IP 66 protection complete all as specified and as directed. |
| 15 | S&F in replacement of unserviceable 35W LED Post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete with all accessories suitable for connection of copper wires complete all as specified and directed. |
| 16 | S & F in replacement Adjustable thermal & magnetic release MCCB 4 pole 100 Amps, 25 KA rating,Ics = 100% Icu (Icu = 25 kA), 415 volts AC complete incl removing of existing U/S one. complete all as specified and directed. |
| 17 | Supply and fix in replacement Intelligent, flexible & smart outdoor lighting control unit DB for automatic switch ON at dusk automatic switching OFF at Dawn with Analog Time Switch, high voltage and low voltage protection, 3 Pole / 230V For 65 Amp load equally distributed over 3 phases. Minimum IP54 Degre of Protection. Complete all as specified and directed. |
| 18 | Supply and fix in replacement Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Analog Time Switch, high voltage and low voltage protection, 3 Pole / 230V For 40 Amp load equally distributed over 3 phases. Minimum IP54 Degre of Protection. complete all as specified and directed. |
| 19 | Supply and fixing in replacement of flood light fitting 150Watt made of Pressure die cast aluminium houseing in powder coated dia costing power coted in gray finish with toughened glass and high power LED and secondary lenses with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection system efficacy > 110/120Lm/W, 10 KV , clamps etc complete all as specified and as directed. |
| 20 | Supply and fixing in replacement of flood light fitting 120Watt made of Pressure die cast aluminium houseing in powder coated dia costing power coted in gray finish with toughened glass and high power LED and secondary lenses with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection system efficacy > 110/120Lm/W, 10 KV , clamps etc complete all as specified and as directed. |
| 21 | Supply and fixing in replacement of flood light fitting 200Watt made of Pressure die cast aluminium houseing in powder coated dia costing power coted in gray finish with toughened glass and high power LED and secondary lenses with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection system efficacy > 110/120Lm/W, 10 KV , clamps etc complete all as specified and as directed. |
| 22 | Disconnection of street light fittings and refixing,Material and labour in replacement for circuit /sub main wiring from junction box to street light fitting complete with 1.5 sqmm 3 core PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial cable 1100 V grade drawn through PVC conduit in street light poles complete all as specified and directed. |
| 23 | M&L in replacement of LT Cable junction box outdoor shall be made out of Polycarbonate reinforced and size should be not less than 205mm x 255mm x 112 mm(upto Cable Size 35/25 sq.mm). The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/69 in accordance with IEC 60695.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60695 - . The Junction Box with Connectors or Terminal Trip or Bus Bar. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one no. MCB SP 'B' curved 6-32 Amp and chromium plated clamps and nut bolts, Glands complete all as per manufacturer’s instructions. complete all as specified and directed. |
| 24 | Supply and Fixing in replacement of LED decorative designer pole including LED designer street light 1X40 Watt 3.5Mtr Long decorative Double bracket decorative side arms , lighting pole made from CRCA , fixture driver, holder, connector, antiquely designed for architectural street lighting applications and facade lighting applications suitable for mounting double street lights etc prewired including connecting up with 3 core copper cable in PVC flexible pipe complete all as specified and as directed. |
| 25 | Material & labour for cleaning away all grass vegetation, scalping shrubs bushes under growth roots and trees up to zero level not exceeding 30 cm girth and removing rubbish up to distance of 50 mtr out the periphery of area under cleanness complete with JCB plants/ Manpower complete all as specified and as directed |
| 26 | Supply and fixing in replacemen energy efficient LED street light fitting of 30 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size. complete all as specified and directed. |
| 27 | Supply and fixing in replacement energy efficient LED street light fitting of 45 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size. complete all as specified and directed. |
| 28 | Supply and fixing in replacement energy efficient LED street light fitting of 60 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size. complete all as specified and directed. |
| 29 | Supply and fixing in replacement analog time switch with 3P module , 24 hours program, programmable for every 15 min with back up of 100 hrs having current capacity of 16 Amp with 01 changeover( 1 CO) complete all as specified and directed. |
| 30 | M&L for preparation of surfaces, scraping of old paint of steel surface of poles and applying two coats of aluminium paint over a coat of red oxide primer of LT steel tubular pole 9 metre hight, single swan neck /double swan neck, Including fixing of reflection tape in altternate coloured of width 6\\" on poles 1.5 to 1.8 metre above the ground level including writing pole number with black letter under yellow circle complete all as specified and directed. |
| 31 | S&F in renewal for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion. complete all as specified and directed. |
| 32 | Supply and laying/ fixing GI tube, light grade, 80mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light polesor as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. |
| 33 | Material and Labour in altering height of security light elevation over the same existing poles in specific locations, repositioning/ realigning directional changes of Security lights affected by High speed wind / Desert Storm over the same existing poles in specific locations as directed |
| 34 | S&F in repairs for rigid non-metallic PVC conduit of 20 mm dia heavy duty alongwith street light poles for wire from junction box to light fittings including fixing arrangement complete all as specified and directed. |
| 35 | Material and labour for Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate for pole base foundation and coping complete all as specified and as directed |
| 36 | M&L in repair cement concrete PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in pole foundation all as specified complete all as specified and directed. |
| 37 | Dismantling of existing unserviceable/cracks PCC poles of any size and type from its position from the site and taking away from site including necessary excavation and earth work in any type of strata,demolition of concrete, disconnecting of street light fitting etc all as specified and as directed. complete all as specified and directed. |
| 38 | Supply, erection of hot dip galvanized octagonal pole of 3mm thickness 8 Mtr long pole with (a) top Dia 70mm & (b) bottom dia 135mm made with having a base plate of (c) Size 225 x 225 x 16mm incliuding cost of nut and bolt and all accessories & including cost of foundation accessories etc. The foundation bolt ( 4 x 20 x 750mm) as per manufacturer design . Hot dip galvanized pole shuld be complete with door locking arrangement, terminal plate consisting of 2 No 100A 4 Pole neutral links with suitable connecting arrangements for 1 No MCB. The cost of RCC 1 : 1:5:3 for foundation of size of 0.7M x 0.7M x 1.8M with minimum 8 Nos 12mm dia longitudian MS reinforcement rods with rings of 8mm dia not more than 200CC for fixing the pole . Including Supply & errection of double arm bracket 1500mm over hange made of 48.3mm outer dia MS pipe of 3mm thick as per IS-1161 welded to canopy 400mm ling with angle of including 105 degree to the vertical canopy. the bracket for holding the fixture should be hot dip galvanized along with 3 nos 10mm dia SS bolt, 2 Nos 40mm dia GI pipe on the pole for cable entry and exit to junction box should be provided. This is including all labour & Material , PCC etc complete job all as specified and as directed. |
| 39 | Cutting of road / hardstanding upto a size not exceeding 20 cms in width and not exceeding 60 cms in depth for laying of LT UG cable protection piep line making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type C1 complete all as specified and as directed. |
| 40 | S&F in replacement LT feeder pillar box factor made cubical type dust proof, out door type both side opening of size 100 x 80 x 40 cm of MS sheet 3 mm thick power coated machine pressed front opening with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of 400 amps 4 strips mounted on insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of suitable size duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type ‘B’ ( using 20 mm graded stone aggregate complete incoming / outgoing cable provision. complete all as specified and directed. |
| 41 | Material & Labour in rectification of LT cable, fault existing / as and when occurs with diagonising equipments as applicable, and by joining with suitable method Note: (a) Diagonising equipments, Skilled labour, Machinaries for excavation and refilling earth work are to be provided / arranged by the contractor at his expenses. (b) If LT cable fault occurs in Road crossing then Road cut surface to be made good after rectification work. (c) GI pipe utilized fo cable protection under Road/ Over wall will be measured and paid separately. complete all as specified and directed. |
| 42 | S&F in replacement of surge protector 10 kA with IP 65 protection, as per IS including taking down existing light from any place to make serviceable the light fitting complete all as specified and as directed |
| 43 | S&F in replacement of driver suitable for 45 watt LED with IP 65 protection, as per IS including taking down existing light from any place to make serviceable the light fitting complete all as specified and as directed |
| 44 | S&F in replacement of driver suitable for 60 watt LED with IP 65 protection, as per IS including taking down existing light from any place to make serviceable the light fitting complete all as specified and as directed |
| 45 | SS&F in replacement of driver suitable for 120 watt LED with IP 65 protection, as per IS including taking down existing light from any place to make serviceable the light fitting complete all as specified and as directed |
| 46 | S&F in replacement of driver suitable for 150/200 watt LED with IP 65 protection, as per IS including taking down existing light from any place to make serviceable the light fitting complete all as specified and as directed |
| 47 | Disconnecting the electric supply from existing high mast panel, dismantling, and taking down laltern carriage of high mast assembly and open up for examination of Engr-in-charge of high mast, dismantling and servicing complete lifting and lowering system,and check the all mechanism assembly is housed in a chasis,pulley, flexible marine grade stainless steel wire rope,trailing cable,lubricating in bearings, cable connection,power tools,fidder pillar box, and reassembling the all mechanism complete and testing on completion all as specified and directed. NOTE-- Replacement of items /spares such as bearing, foundation nuts, bolts, washers, fresh grease, pulley ,chain,belt shall be deemed to be included in the above items & not be paid separately.all as specified and directed . 1. Cost of Necessary tools and plants such as ladders, hydra for repair of high raised high mast light fittings etc should be deemed to be included in the unit rate quoted. |
| 48 | Supply and fixing in replacement of flexible marine grade stainless steel wire rope without any intermediate joints and shall consists of only non corrodible as per existing size/grade (304 or 316) in flexible 7/19 breaking capacity of rope is 2350 kg x 2 all as specified and directed |
| 49 | Supply and fixing in replacement of double drum winch complete mechanism system including 140/90 SAE lubricant as per existing make and capacity,and safe working load 750 Kg complete all as specified and directed. |
| 50 | Supply and fixing in replacement of trailing cable flexible EPR insulated PCP sheathed round copper conductor power cable 5 core x 4 sqmm copper. Complete all as specified and directed. |
| 51 | Taking out from high mast winch/power tool and repairs,servicing and rewinding with super enameled copper conductor of existing size , testing on completion to electric motor 1/1.5 HP all as specified and directed . |
| 52 | S&F copper wire of size 2.5 Sqmm x 3 core PVC insulated unsheathed multistrand EC grade bright annealed copper industrial cable of 1100 volts as per IS: 694 complete all as specified and directed. |
| 53 | S&F copper wire of size 4 Sqmm x 3 core PVC insulated unsheathed multistrand EC grade bright annealed copper industrial cable of 1100 volts as per IS: 694 complete all as specified and directed. |
| 54 | S&F copper wire of size 6 Sqmm x 3 core PVC insulated unsheathed multistrand EC grade bright annealed copper industrial cable of 1100 volts as per IS: 694 complete all as specified and directed. |
| 55 | S&F in replacement of U/S flood light luminaire fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection,power backup in case of power failure, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 60 W LED as specified and directed. |
| 56 | S&F in replacement of HPSV/MH High bay light fitting with highbay luminare LED light fitting 200 watts incl clamp / nut & bolt, system wattage: 200 W, Lumen package : 24000 Lm, luminaire efficacy:> 120 Lm/W, four stage electrical protection : over/under voltage protection, short circuit and reverse polarity protection, Over temperature protection, Die-cast aluminium housing with dedicated optics for excellant beam distribution, Life: 50000 Hrs @L70, color temperature : 5700K + 300K, surge protection of internal 4kV and external 4kV complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted. |
| 57 | S&F in replacement of HPSV/MH High bay light fitting with highbay luminare LED light fitting 250 watts, system wattage: 250 W, Lumen package : 24000 Lm, luminaire efficacy:> 120 Lm/W, four stage electrical protection : over/under voltage protection, short circuit and reverse polarity protection, Over temperature protection, Die-cast aluminium housing with dedicated optics for excellant beam distribution, Life: 50000 Hrs @L70, color temperature : 5700K + 300K, surge protection of internal 4kV and external 4kV complete all as specified and directed. Note:- Cost of neccessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay / low bay luminaires, suitable hanging items such as clamps/hooks/down rod etc should be deemed to be included in the unit rate quoted. |
| 58 | S&F in renewal MCB TPN 63 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed |
| 59 | S&F in renewal MCB TPN 40 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed |
| 60 | S&F in renewal MCB SPN 40 Amp C curves MCB repturing capacity 10 KA etc complete all as specified and directed |
| 61 | S&F in renewal MCB SP 6 to 32 Amp C curves MCB repturing capacity 10 KA etc complete all as specified and directed |
| 62 | Supply & fix in replacement of LED Aviation obstruction light 9 watt with light dependent sensor, IP65 protected. Complete all as specified and as directed |
| 63 | S&F in replacement LT feeder pillar box factry made cubical type dust proof, out door type both side opening of size 50 x 60 x 20 cm of MS sheet 3 mm thick power coated machine pressed front opening with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of 400 amps 4 strips mounted on insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of suitable size duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type ‘B’ ( using 20 mm graded stone aggregate complete incoming / outgoing cable provision. complete all as specified and directed. |
| 64 | S&F in replacement of Solar Street Light all in one 50 Watt stand alone solar LED Street Light with integrated PV Solar panel, Charge controller, Rechargebale LI Battery pack , Passive infrasensor for dimming operation , Battery charge monitoring cable free Installation fixed with SS screw with inbuilt charge controller and auto switch from dusk to dawn operation with ingress protection complete all as specified and directed. NOTE :- item No 1 to 63 Cost of Necessary tools and plants such as ladders, hydra etc for connection to street light fittings should be deemed to be included in the unit quoted rate Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender