Tender For Repair/Maint And Improvement To Certain Water Supply Installations & Distribution Network And Attending Complaints At Technical Area Under Aor Of Ge (A) Jaisalmer
Tender Value
49.50 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
11 days left
EMD
99000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint And Improvement To Certain Water Supply Installations & Distribution Network And Attending Complaints At Technical Area Under Aor Of Ge (A) Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-charge. |
| 2 | M&L for rendering 15 mm thick readymade plaster on inner/outer walls with approved make by adding 17-19% of potable water by weight of material. For thickness above 15 mm it is recommended to be applied in multiple layers. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and directed by Engineer-in-charge.Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height all as specified and directed) |
| 3 | M & L for Applying 1mm thick wall care putty on wall for desired smoothness and levelling of surfaces in two or more layers) for receiving painting complete all as specified and directed by Engineer-in-charge. |
| 4 | M&L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed by Engineer-in-charge. |
| 5 | M&L for preparation of newly plastered surfaces and applying Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. complete all as specified and directed by Engineer-in-charge. |
| 6 | M&L for rendering 5 mm thick readymade plaster on inner/outer walls with approved make by adding 17-19% of potable water by weight of material. Ready-mix plaster shall complies with IS 1661-1972, IS 2250-1965, IS 2402-1963 and confirms the Compressive strength @ 28 Days- 10-12 Mpa/ Bulk density- 1500-1600 Kg/m3 complete all as specified and directed by Engineer-in-charge. Note :The rate quoted by contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20mtr height all as specified and directed) |
| 7 | M& L for applying three coats of white wash on ceiling surface including prepration of new surface complete all as specified and directed by Engineer-in-charge. |
| 8 | M&L for MS props erecting for temporary supports to the structural members like beams, slabs etc. to relieve the load on the members during breaking of damaged concrete, removal guniting, excavation or any dismantling work as per the instruction of engineer in-charge. These supports shall be provided either in the form of props or trestles fabricated using structural steel as per the site requirements complete all as specified and directed by Engineer-in-charge. |
| 9 | M & L for Chipping of slab/columns/beams/chajjas/parapet/roof projection/balcony/staircase and removing loose mortar with chisel hammer without much impact on concrete surface, clean the surface by sand blasting the surface using river sand with minimum of 6 kg pressure at the nozzle or air blow by electric pressure blower by mechanical compressor, cleaning the exposed reinforcement with wire brushes etc and disposal of debris for all lead and lifts, complete all as specified and directed by Engineer-in-charge. |
| 10 | M & L for Cleaning & applying rust remover (Sika rustoff100) in two coats over rusted reinforcement surface and providing anti corrosive coating with two component epoxy based zinc rich primer/Rust passivation Inhibitor coat at the rate of 6-8 sq. mtr/ltr not less than 50 microns dft with Sika friazinc R or equivalent to reinforcement surface as per manufacturer’s instructions including all scaffolding, machinery, tools tackles and clearing of debris. complete all as specified and directed by Engineer-in-charge. |
| 11 | M&L for applying to the damaged concrete portion of slab/ columns/ beams/ chajjas/ parapet / roof projection /balcony/ staircase with single component, fiber reinforced, dual shrinkage- compensated thixotropic, cementitious ptch repair mortar Sika monotop 122F (having the technical parameters mentioned in material specifications) capable of applying up to 20-25mm thick in double layer initially by hand and finishing with troweled carefully compacting the same around the rebar and finishing to bring it in line with existing concrete surface with an average specified thickness complete all as specified and directed by Engineer-in-charge. |
| 12 | BONDING COAT: Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC roof as per specifications and direction of Engineer-In-charge complete in all respect. SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer of make complete all as specified and directed by Engineer-in-charge. |
| 13 | Tender Application Note :- (i) From serial No. 12, 13, 17 and 18 for the structural rapair and strengthening and rehabilitation and roof treatment shall be applied by the company’s authorized applicator firm only.(ii) Contractor have to get prior approval of applicator or authorized agency by submitting its authorization letter to this office for approval prior to commencement of work. Department will conduct an official varification from manufacturer of its authorised agency. (iii) Submission of 10 year warranty certificate for structural repair and roof waterproofing treatment work over roof is mandatory after completion of work. (iv) The cost of Scaffolding work required at certain places is including in the respective items catered for repairs itself. No extra shall be paid for the same. |
| 14 | Complete removal of existing treatment on wall (any number of layers) by scarping with steel scrapers or any other mean and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer-in-charge. |
| 15 | Complete removal of existing treatment on wall (any number of layers) by scarping with steel scrapers or any other mean including filling depressions of scrapped surface with putty and including priming plastered and other surfaces with alkali resistant priming paint and Material and labour for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified and directed by Engr-in -Charge. |
| 16 | M & L for preparation of old plastered ceiling surfaces and applied one coats of white wash complete all as specified and as directed by Engineer in charge. |
| 17 | S&F in repairs steel rolling shutters, 1.00mm thickness of laths with out ball bearing,but gear operated type with bevel gear box and crank handle as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete. Note :- Rate including greasing, change of rod, lock, cover hood and other accessories as required. |
| 18 | Dismantling of structural steel work including doors, gates but excluding framed truss etc complete all as specified and as directed by Engineer in charge. |
| 19 | M & L for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed by Engineer in charge. |
| 20 | S&F in repair 1.60 mm Mild steel, plain, black sheet for covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed,holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required |
| 21 | M&L for preparation of new or previously untreated steel surfaces and applying two coats of synthetic enamel paint over a coat of primer red oxide, zinc chrome complete all as specified and as directed by Engineer in charge. |
| 22 | Dismantling of plain or corrugated steel sheets in roof coverings any type complete all as specified & directed by Engineer in charge. |
| 23 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting, 0.50 mm thick, of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 24 | M & L for plain sheet glass plain 3mm thick ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane including hacking out of old/broken glass complete all as specified and as directed. |
| 25 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.Note : Work will be in patches or in bulk |
| 26 | M & L for Machine cut kota stone slab flooring 20-25mm thick over, laid over cement screed base , jointed and pointed with grey cement slurry mixed with pigment over 20mm thick cement mortar 1:6 screed bed to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge.Note : Work will be in patches or in bulk |
| 27 | M & L for Machine cut kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10 mm thick cement plaster 1:3 jointed and pointed with grey cement slurry mxed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer-in-charge. |
| 28 | M & L for Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed by Engineer-in-charge. |
| 29 | Demolition of cement concrete un-reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified and directed by Engineer-in-charge. |
| 30 | M & L for 75 mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in subbase of flooring / hard standing complete all as specified and directed by Engineer-in-charge. |
| 31 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. Note: colour and design as approved by GE |
| 32 | Dismantling of posts or struts (wood, steel or RCC ) any section including taking out embeded portion and making good distrubed ground on concrete , brick work, masonry etc and removing of demolished materials out side MD land complete all as specified and directed by Engineer-in-charge. |
| 33 | M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165 ,etc complete all as specified and directed by Engineer-in-charge. |
| 34 | Dismantling fencing wire mesh, any type complete all as specified and directed by Engineer-in-charge. |
| 35 | Supply Chain link MS galvanisd fencing, any size or type complete all as specified and directed by Engineer-in-charge. |
| 36 | Fixing only chain link MS galvanisd fencing, any size or type complete all as specified and directed by Engineer-in-charge. |
| 37 | S/F mild steel round Bar 10 mm dia cut to length bent to shape as required, for fixing chain link fencing fixed with nut & bolt as in tie bar complete all as specified and directed by Engineer-in-charge. |
| 38 | S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290. Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel') complete all as specified and directed by Engineer-in-charge. |
| 39 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 5cm but not.exc 10 cm long,diameter of neck 11 to 15 mm complete all as specified and directed by Engineer-in-charge. |
| 40 | S & F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and training and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed by Engineer-in-charge. |
| 41 | Supply, Install, testing and commissioning of Ultrasonic Water Flow Meter, Model: DN150 4G based Flow Principle: Ultrasonic Time of Flight, Transit Time. Rvalue: R40/R160/R500 Accuracy: 2% Q1: 6.25 m3/h,Q3: 250 m3/h Construction: Pipe -Engineering Plastic; Enclosure: Polycarbonate; Input : Battery - LiSoCl2 - 3.6V Display: 8 digit LCD with UV protection Coat; Communication: None; Measurements: Flow Rate & Totalizer Volume; |
| 42 | M&L for welding of flanges and changes to supply line of size DN150 for back pressure complete all as specified and directed by Engr-in-Charge. |
| 43 | Supply, Install, testing and commissioning of Multifunction Meter for Energy measurement 3 Phase - V, I, Kw, Kwh, KVAH, PF, Freq with higher class of accuracy suitable for Telemetry, Radar Level Sensor as recommended by OEM including taking down old existing one complete all as specified and directed by Engr-in-Charge. Make: Swan Env Pvt ltd/Sun Teknology/next or equivalent in PS.Note:- (a) Design should be prior approved by GE. (b) Installation and Testing shall be carried out by OEM only at site in presence of JE E/M, Engr-in-Charge & Satisfactory testing reports shall be submitted before release of payment, if not contractor shall rectify the same till obtaining testing reports satisfactory without any additional cost. |
| 44 | Supply, Install, testing and commissioning of 4G LTE Based RS485 Telemetry for Reading Data from Level Sensors Input: 120-270V AC 50Hz ; Power: 10 watts LTE Bands: LTE-FDD: B1, B3, B5, B8LTE-TDD: B34, B38, B39, B40, B41 Fall Back to 2G: 900 MHz, 1800 MHz RS485: Half Duplex, 5 Slaves ( Extendable ) RS485 Registers Configuration: Onsite over WiFi/BLE & Cloud SMPS Standards: Safety Standars: UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004, CCC GB4943.1, BSMI CNS15598-1, BISIS13252(Part1): 2010/IEC 60950-1: 2005 approved. Protection: Fuse & Metal Oxide Variastor for Surge ,Antenna: WideBand(800-2800Mhz), SMA Antenna - 50 Ohms; Wire Termination: Push Plugs ,Wire Entry: M12 Cable Glands Enclosure: IP65, Polycarbonate Enclosure Output: 5V, 200mA Optional including taking down existing one complete all as specified and directed by Engr-in-Charge. Make: Swan Env Pvt ltd/Sun Teknology/next or equivalent in PS.Note:- (a) Design should be prior approved by GE. (b) Installation and Testing shall be carried out by OEM only at site in presence of JE E/M, Engr-in-Charge & Satisfactory testing reports shall be submitted before release of payment, if not contractor shall rectify the same till obtaining testing reports satisfactory without any additional cost.. |
| 45 | Supply, Install, testing and commissioning of Radar Level Sensor - Non Contact Input: 9-30V DC; Max Range : 7 Meters Beamwidth: 65° (H-plane), 53° (E-plane) typical half-power beam width; Accuracy: ±5mm max Resolution: 1mm including taking down existing one complete all as specified and directed by Engr-in-Charge. Make: Swan Env Pvt ltd/Sun Teknology/next or equivalent in PS.Note:-(a) Design should be prior approved by GE. (b) Installation and Testing shall be carried out by OEM only at site in presence of JE E/M, Engr-in-Charge & Satisfactory testing reports shall be submitted before release of payment, if not contractor shall rectify the same till obtaining testing reports satisfactory without any additional cost. |
| 46 | Supply, Install, testing and commissioning of Solar Kit 20 Watt Mono Crystalline Panel 26Ah SMF Battery Charge Controller with 12V DC output Panel Box with stand OEM Standard including taking down existing one complete all as specified and directed by Engr-in-Charge. Make: Swan Env Pvt ltd/Sun Teknology/next or equivalent in PS.Note:- (a) Design should be prior approved by GE. (b) Installation and Testing shall be carried out by OEM only at site in presence of JE E/M, Engr-in-Charge & Satisfactory testing reports shall be submitted before release of payment, if not contractor shall rectify the same till obtaining testing reports satisfactory without any additional cost. |
| 47 | Taking up carefully from trenches/walls/pillar CI/DI/GI water mains incl all fittings with spigot and socket ends incl joint/rubber gaskets/lead wool/tyton joint for the following sizes:- |
| 48 | (a) 80 mm bore. |
| 49 | (b) 100 mm bore. |
| 50 | (c) 150 mm bore. |
| 51 | (d) 200 mm bore. |
| 52 | (e) 250 mm bore. |
| 53 | (f) 350 mm bore. |
| 54 | Relaying, realigning the DI/CI/GI pipe line with spigot and socket ends (in any length) on trench/surface/pillars with necessary fitments (tyton joint/rubber gasket,etc) for complete assembly of following sizes complete in all respect all as specified & directed by Engineer-in-charge. |
| 55 | (a) 80 mm bore. |
| 56 | (b) 100 mm bore. |
| 57 | (c) 150 mm bore. |
| 58 | (d) 200 mm bore. |
| 59 | (e) 250 mm bore. |
| 60 | (f) 350 mm bore. |
| 61 | Supply and laying ductile iron pipe with internal cement mortar lining and external zink pipes with class of pipe K-9 of following sizes:- |
| 62 | (a) 80 mm bore. |
| 63 | (b) 100 mm bore. |
| 64 | (c) 150 mm bore. |
| 65 | (d) 200 mm bore. |
| 66 | (e) 250 mm bore. |
| 67 | (f) 350 mm bore. |
| 68 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge. |
| 69 | Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge. |
| 70 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-Charge. |
| 71 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock all as specified & directed by Engineer-in-Charge. |
| 72 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed, at a level n.exc 1.5m above the starting point, complete all as specified and directed by Engineer-in-charge. |
| 73 | Removing excavated materials (soft / disintegrated rock) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-charge. |
| 74 | Taking down old u/s butterfly valve of any size. |
| 75 | S & F in repairs butterfly valve, high pressure with crutch or butterfly handle for iron pipe or for unions of follwing sizes complete all as specified. |
| 76 | (a) 80 mm bore. |
| 77 | (b) 100 mm bore. |
| 78 | Taking down old u/s Sluice valve of any size |
| 79 | Supply and fix Sluice valve PN-1.6 with SS spindle and wedge nut ISI maked (IS-14846:2000) complete with iron wheel of following sizes:-Note:- Rate includes neccesary arrangements and cutting the pipe of required dimension with attachments for fitting the sluice valve. |
| 80 | (a) 80 mm bore. |
| 81 | (b) 100 mm bore. |
| 82 | (c) 150 mm bore. |
| 83 | (d) 350 mm bore. |
| 84 | Fixing only Sluice valve (Schedule-'B' item) complete with iron wheel of following sizes:-Note:- (i) Rate includes neccesary arrangements and cutting the pipe of required dimension with attachments for fitting the sluice valve. (ii) Old u/s valve issued against sch of credit |
| 85 | (a) 200 mm bore. |
| 86 | (b) 250 mm bore. |
| 87 | M & L for fixing of gland in sluice valve complete of following sizes :- |
| 88 | (a) 80 mm bore. |
| 89 | (b) 100 mm bore. |
| 90 | (c) 150 mm bore. |
| 91 | (d) 200 mm bore. |
| 92 | (e) 250 mm bore. |
| 93 | (f) 350 mm bore. |
| 94 | M & L for taking out sluice valves refacing , regrinding and refixing alongwith rubber gasket complete of following sizes :- |
| 95 | (a) 80 mm bore. |
| 96 | (b) 100 mm bore. |
| 97 | (c) 150 mm bore. |
| 98 | (d) 200 mm bore. |
| 99 | (e) 250 mm bore. |
| 100 | (f) 350 mm bore. |
| 101 | M & L for taking out stainless steel spindle out of sluice valve and refixing it with new one including check nut with neccessay attachments to fit the existing valve complete for the following sizes :- |
| 102 | (a) 80 mm bore. |
| 103 | (b) 100 mm bore. |
| 104 | (c) 150 mm bore. |
| 105 | (d) 200 mm bore. |
| 106 | (e) 250 mm bore. |
| 107 | (f) 350 mm bore. |
| 108 | S & F in repairs foot valve cast iron assembly of following sizes:- |
| 109 | (a) 50 mm bore. |
| 110 | (b) 65 mm bore. |
| 111 | (c) 80 mm bore. |
| 112 | (d) 100 mm bore. |
| 113 | (e) 150 mm bore. |
| 114 | Repairs to foot valve (cast iron) by opening from suction line of pumpset , replacement of u/s rubber gasket sheet, nut boltsand refixing on existing position and testing of foot valve fuctioning of following sizes:- |
| 115 | (a) 50 mm bore. |
| 116 | (b) 65 mm bore. |
| 117 | (c) 80 mm bore. |
| 118 | (d) 100 mm bore. |
| 119 | (e) 150 mm bore. |
| 120 | Supply and fix in replacement cast iron non return (reflux) valve both flanged ends in swing type design as per IS 5312 Part-1, PN-1.0, of following sizes:- |
| 121 | (a) 80 mm bore. |
| 122 | (b) 100 mm bore. |
| 123 | (c) 150 mm bore. |
| 124 | Repairs to cast iron air release valve with two air outlet including replacement of washer, sheet ,lever mechanism and float , nut bolts as per existing capacity from DI pipeline complete of follwing sizes all as specified & directed by Engineer-in-charge. |
| 125 | (a) 100 mm |
| 126 | (b) 80 mm |
| 127 | (c) 65 mm |
| 128 | M&L in repairs for fixing MS leakage clamps 150 mm in width made out of 6 mm thick MS Sheet in shape and size duly drilled 2 holes in each side with necessary rubber insertion sheet of required size and MS bolt,nuts & washers incl. excavation/earth work in any type of strata and dewatering of line water for prevention of water leakage from pipeline all as specified and directed suitable for following sizes of CI/DI pipelines:- |
| 129 | (a) 80 mm bore. |
| 130 | (b) 100 mm bore. |
| 131 | (c) 150 mm bore. |
| 132 | (d) 200 mm bore. |
| 133 | M & L for Burning of lead joint in position (old lead will be contractors property for which credit will be given separately) for the pipes of following sizes:- |
| 134 | (a) 80 mm bore. |
| 135 | (b) 100 mm bore. |
| 136 | (c) 150 mm bore. |
| 137 | S&F in replacement mechanical/Detachable/Victaulic joints(class 10) with nut bolts washers rubber gaskets etc suitable for CI/DI pipes of following sizes:- |
| 138 | (a) 80/100 mm bore. |
| 139 | (b) 150/200 mm bore. Please Enable Macros to View BoQ information |
| 140 | (b) 150/200 mm bore. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender