Tender For Repair / Maintenance Of Lt Cable, Lt Panel Board And Its Switchgears At Technical Area Under Afs Phalodi.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
03 Oct 2026
5 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jodhpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Lt Cable, Lt Panel Board And Its Switchgears At Technical Area Under Afs Phalodi.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Garrison Engineer (AF), Air Force Station, Phalodi Name of Work : REPAIR / MAINT OF LT Cable, LT Panel board and its switchgears at Technical Area under AFS Phalodi. Contract No: GE (AF) PHALODI/ OF 2026-27 Serial Page No. Bidder Name : SCHEDULE 'A'(BOQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT TEXT # NUMBER TEXT NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER NUMBER # TEXT Srl.No. Item Description Item Code / Make Approx No of Units reqd Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil. Complete all as specified and directed.Note:- Any excavation in SDR/Loose soil/PCC/Hardstanding/Interlocking tiles/Bituminous pavement shall be carried out by manual mode only irrespective of Tech/Residential area. In case of mechanical excavation engaged by the contractor, any fault due to rupturing of communication/power/any other utility lines shall be rectified by appropriate joint as per direction of Engr-in-Charge/GE/Stn Auth as deemed fir and no extra cost will be paid in this respect. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and directed. |
| 4 | Removing of excavated soil to a distance n. exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point Complete all as specified and directed. |
| 5 | Supply & spread unwashed Crushed stone sand for sand cushioning for covering the under ground cable in trenches complete all as specified and directed. (Note :- Punning thickness shall be measured.) |
| 6 | Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm across the cable in trenches Complete all as specified and directed. |
| 7 | Taking out Unsv U/G cable PVC insulated armoured PVC sheathed LT type of 10 sqmm to 16 sqmm any size complete all as specified and directed. |
| 8 | Taking out Unsv U/G cable PVC insulated armoured PVC sheathed LT type of 25sqmm to 50 sqmm any size complete all as specified and directed. |
| 9 | Taking out Unsv U/G cable PVC insulated armoured PVC sheathed LT type of 70 sqmm to 120 sqmm any size Complete all as specified and directed. |
| 10 | Taking out Unsv U/G cable PVC insulated armoured PVC sheathedLT type of 185 sqmm to 240 sqmm any size Complete all as specified and directed. |
| 11 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 240 Sqmm 3.5 core Complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 12 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 185 Sqmm 3.5 core Complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 13 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 120 Sqmm 3.5 core Complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 14 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 95 Sqmm 3.5 core Complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 15 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 70 Sqmm 3.5 core Complete all as specified and directed. Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 16 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 50 Sqmm 3.5 core Complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 17 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 25 Sqmm 4 core Complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 18 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 16 Sqmm 4 core Complete all as specified and directed Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 19 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes of 10 Sqmm 2 core Complete all as specified and directed.Note:- (i) Cable may be laid in trenches, under road, across the Nallah, along poles/walls and ducts etc.(ii) Excavation, earthwork, sand cushioning, cable cover, pipe for cable protection to be measured and paid separately. |
| 20 | Relaying of LT XLPE underground cable with proper connection in trenches / pole etc, aluminium conductor of any sizes complete all as specified and directed .(Note:- Excavationon with Earth Work,sand cushioning will be measured under respective item of BOQ) |
| 21 | S&F in repair on existing location including taking out of existing ACB(Air Circuit Breaker of 800 Amp 4 Pole capacity. Complete all as specified and directed. |
| 22 | S&F in repair on existing location including taking out of existing ACB(Air Circuit Breaker of 1000 Amp 4 Pole capacity. Complete all as specified and directed. |
| 23 | S&F in repair on existing location including taking out of existing MCCBs of MCCB 415 volts thermal magnetic release adjustable type 630 Amps 04 pole 50KA capacity. Complete all as specified and directed. |
| 24 | S&F in repair on existing location including taking out of existing MCCBs of MCCB 415 volts thermal magnetic release adjustable type 400 Amps 04 pole 36KA capacity. Complete all as specified and directed. |
| 25 | S&F in repair on existing location including taking out of existing MCCBs of MCCB 415 volts thermal magnetic release adjustable type 250 Amps 04 pole 36 KA capacity. Complete all as specified and directed. |
| 26 | S&F in repair on existing location including taking out of existing MCCBs of MCCB 415 volts thermal magnetic release adjustable type 200 Amps 04 pole 36 KA capacity. Complete all as specified and directed. |
| 27 | S&F in repair on existing location including taking out of existing MCCBs of MCCB 415 volts thermal magnetic release adjustable type 160 Amps 03 pole 36 KA capacity. Complete all as specified and directed. |
| 28 | S&F in repair on existing location including taking out of existing MCCBs of MCCB 415 volts thermal magnetic release adjustable type 100 Amps 04 pole 25 KA capacity. Complete all as specified and directed. |
| 29 | S&F in repair on existing location including taking out of existing MCCBs of MCCB 415 volts thermal magnetic release adjustable type 63 Amps 04 pole 25 KA capacity. Complete all as specified and directed. |
| 30 | S&F in repair MCB TPN 63Amps C curve 415 V, 10 KA Complete all as specified and directed. |
| 31 | S&F in repair MCB TPN 40 Amps C curve 415 V, 10 KA Complete all as specified and directed. |
| 32 | Taking out old u/s pipe of any size Complete all as specified and directed. |
| 33 | S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of 40 mm bore Complete all as specified and directed. |
| 34 | S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of 50 mm bore Complete all as specified and directed. |
| 35 | S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of 80 mm bore Complete all as specified and directed. |
| 36 | S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of 100 mm bore Complete all as specified and directed. |
| 37 | M&L for cutting of road / hardstanding upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable protection pipe line and finished surfaces by extracted material and provided with Trimix Bitumen top layer to match the existing surfaces and remove surplus extracted material 50 m away complete all as specified and directed. |
| 38 | Tracing out the Fault in existing Underground LT cables network under any depth below or above the existing earth surface by earth work, fault locator machine, expertise staff and repair the same by required spares materials in existing position whenever informed by Engr -in-charge or JE E/M incl testing on completion. Note : 1. The all T&P and earth work shall be included in quoted rates and no extra cost shall be claim by the contractor. 2. The neccessary Materials any type required to repair the fault will be measured and paid seperatly under relevent item of sch A. |
| 39 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of 16 Sqmm to 25 Sqmm size after detaction of fault location . Complete all as specified and directed.Note: Earth work and returning filling which required will be included in above job . |
| 40 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of 35 Sqmm to 50 Sqmm size after detaction of fault location . Complete all as specified and directed.Note: Earth work and returning filling which required will be included in above job . |
| 41 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of 70 Sqmm to 120 Sqmm size after detaction of fault location . Complete all as specified and directed.Note: Earth work and returning filling which required will be included in above job . |
| 42 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of 150 Sqmm to 185 Sqmm size after detaction of fault location . Complete all as specified and directed.Note: Earth work and returning filling which required will be included in above job . |
| 43 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of 240 Sqmm to 400 Sqmm size after detaction of fault location . Complete all as specified and directed.Note: Earth work and returning filling which required will be included in above job . |
| 44 | Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose suitable for electrical shock safety of sizes 2m x 1m Complete all as specified and directed. |
| 45 | Supply & fix in repair High performance microprocessor based 3 phase APFC relay control panel with Auto/Manual Option including control CT & control wiring of the panel. Complete all as specified and directed. |
| 46 | Material and Labour for cleaning of dust particles from inside the LT Panel by air blowers, tightening of loose connections,removing damage insulation and free cable from loop,cut out damage LT cable and refixing to busbar with Aluminium Lugs filling of gaps with sealants, removing of vegetation, surface dressing surrounding the panel, welding of damaged panel doors, fixing of hinges, providing locking arrangements(L drop both side), applying one coat of primer, painting of panel with two coats synthetic enamel paint of existing colour complete all as specified and directed. |
| 47 | M& L in Repair for Earthing complete with galvanised mild steel plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end connected to metallic bodies of LT equipment etc at the other and earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x4 mm flat iron clamps bolts, nuts and washers and including providing watering pipe 20mm bore GI Pipe electrode complete all as specified and shown in elctrical plate No 3 of MES SSR Part-I. the scope of work includes necessary excavation and earth work in any type of soil. removal of soil upto 50 metre PCC pit with precast RCC cover, charcoal/salt funnel, CI frame etc complete all as specified & directed.NOTE:(I) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC(1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars @ 150mm c/c both ways.(ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. (iii) Item includes cost of 7.5 metre earth lead strip (iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thinkness of 15 cm on all sides. |
| 48 | S&F in replacement of decotrative LED light column 3 mtr height of 40 watt with cylindrical aluminium pipe housing opaque diffuser (Tiranga colour) made from engineering grade polymer for rugged outdoor IP-65 including PCC foundation and Anchor bolt and nut complete all as specified and as directed. |
| 49 | Supply, install, testing and commissioning factory made (CPRI test certified) LT panel box (KIOSK) out door type platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with insulated AL bus bars installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner 3.15 mm thick and individual compartment for MCCB/MCB & volt/Amps meter and 50 x 50 x 5 mm thick angle iron for base frame work.The complete feeder pillar box should be powder coated including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type with approx size for cable entry,danger plate with double door shutter including locking arrangement (L drop Lock both side) as per manufacturers with 2 Lock and Keys. (a) Incoming- MCCB 4 pole 160 A , 415V,36 KA adjustable type with magnetic release - 01 No. (b) Digital Voltmeter size 96 x 96 mm, 0-600 volts with selector switch - 01 No. (c) Digital Ammeter size 96 x 96 mm 0-400 Amps, CTs, CTR 0-400 Amps with selector switch - 01 No. (d) Busbar alluminium 250 A capacity Note: panel mounted on 45 cm height pcc platform above ground level and 0.35 below ground level (Rate to be inclusive in quoted ) |
| 50 | S&F in replacement of copper wire of size 10 sqmm 3 core PVC insulated unsheathed multistrand EC grade bright annealed copper inustrial cable of 1100 volt as per IS :694 complete all as specified and as directed. |
| 51 | S&F in repair LED type building security light of capacity 35 watt of white colour light with driver, having luminaries Efficiency not less than 100 lm / Watt, fixed in Pressure Die Cast Aluminum housing, & glass cover, Ingress protection of IP 65, including all necessary fitting & fixture,& connecting complete all as specified & directed |
| 52 | Demolition of old PCC and M&L for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal of poles or Panel / coping including necessary formwork, fair finishing to exposed surfaces using extra cement complete all as specified & directed |
| 53 | S&F in replacement new generation energy saving and environmental friendly long life varsatile pressure die cast aluminium IP66 road way light fitting with high power LED as light source of capacity 60 watts (Surge protection of the light should be 10 KV )with suitable drivers etc fixed to Pole/Wall in any position including taking down all complete specified & directed |
| 54 | S & F in replacement 4 sqmm solid conductor 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed twin core cable flat or circular from junction box to fitting complete all as specified and directed |
| 55 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 400 Sqmm complete all as specified and directed |
| 56 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 300 Sqmm complete all as specified and directed |
| 57 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 240 Sqmm complete all as specified and directed |
| 58 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 185 Sqmm complete all as specified and directed |
| 59 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 120 Sqmm complete all as specified and directed |
| 60 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 95 Sqmm complete all as specified and directed |
| 61 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 70 Sqmm complete all as specified and directed |
| 62 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 50 Sqmm complete all as specified and directed |
| 63 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 35 Sqmm complete all as specified and directed |
| 64 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 25 Sqmm complete all as specified and directed |
| 65 | Supply and fix in repair LT Aluminium Lugs in Existing Panel of 16 Sqmm complete all as specified and directed |
| 66 | M&L for Replacement of broken earth chamber cover by providing RCC cover of (1:2:4), Type B-1, using 20mm graded stone aggregate of size 550mmx550mmx40mm thick, reinforced with 8mm dia MS TMT bars @100 mm C/C both ways with MS handle 12mm dia complete all as specified and as directed. |
| 67 | Supply, install, test and commissioning factory made THERMOPLASTIC/HDPE CABLE JUNCTION BOXES IP 66/67 “weather proof”, with terminals for outdoor installation (with knockouts for cable entry) of size 280 x 170 x 105 mm depth with cable entry size of 10-25 sqmm with 4 No. busbar of capacity 63 Amp and MCB SP 6 Amp-1 No.of make sintex each, with flat iron clamps of size 25 x 4 mm, nuts and bolts complete including taking down all as specified and directed. |
| 68 | S&F in repair Digital Voltmeter size 96 x 96 mm, 0-600 volts with selector switch complete all as specified & directed |
| 69 | S&F in repair Digital Ammeter size 96 x 96 mm 0-400 Amps, CTs, CTR 400/5, Amps with selector switch complete all as specified & directed |
| 70 | M&L Danger notice plate in replacement of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified & directed |
| 71 | S&F in repair ON LOAD change over switch 415V with , fitted at Existing LT panel complete of 4 pole of capacity 630 Amps Sizes as specified & directed |
| 72 | S&F in repair ON LOAD change over switch 415V with , fitted at Existing LT panel complete of 4 pole of capacity 400 Amps Sizes as specified & directed |
| 73 | S&F in repair ON LOAD change over switch 415V with , fitted at Existing LT panel complete of 4 pole of capacity 250 Amps Sizes as specified & directed |
| 74 | S&F in repair ON LOAD change over switch 415V with , fitted at Existing LT panel complete of 4 pole of capacity 160 Amps Sizes as specified & directed |
| 75 | S&F in repair ON LOAD change over switch 415V with , fitted at Existing LT panel complete of 4 pole of capacity 125 Amps Sizes as specified & directed |
| 76 | S&F in repair ON LOAD change over switch 415V with , fitted at Existing LT panel complete of 4 pole of capacity 100 Amps Sizes as specified & directed |
| 77 | S&F in repair ON LOAD change over switch 415V with , 4 pole of capacity 200 Amps with enclosure box fitted at pole/wall complete as specified & directed . |
| 78 | S&F in repair ON LOAD change over switch 415V with , 4 pole of capacity 100 Amps with enclosure box fitted at pole/wall complete as specified & directed . |
| 79 | Supply and laying of Aggregate for protection of LT panel gauge 20 mm to 40 mm grade complete all as specified and directed at site. |
| 80 | M&L in repair for cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate for foundation of LT Panel or LT Pole / coping including necessary formwork, fair finishing to exposed surfaces using extra cement including demolition of PCC complete all as specified and directed. |
| 81 | M&L in repair for LT cable route indicator made out of PCC (1:2:4) type B-0(12.5mm graded aggregate of size 1000mm (H) x 120mm (W) x 80mm (thick), painted with Specified colour lettering synthetic enamel paint and embedded in PCC block (1:3:6) type C2 (using 40mm grade aggregate ) of size 150mm x 150mm x 200mm including necessary excavation for PCC block, placed at interval of 30Mtr complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST