Tender For Special Repair For Replacement Of Overhead Street Light Conductor To Underground Cable For Vikram And Shakti Enclave (Tender Id No : 2026_Mes_789113_1)
Tender Value
39.98 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
18 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair For Replacement Of Overhead Street Light Conductor To Underground Cable For Vikram And Shakti Enclave (Tender Id No : 2026_Mes_789113_1)
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling of existing old unserviceable OH Aluminium Conductor from street light poles of any size from any descritpion |
| 2 | Dismantling of existing old unserviceable insulators from street light poles of any size from any descritpion |
| 3 | Dismantling of existing old unserviceable cross-arms of M.S. channel or angle sections etc from street light poles of any size. |
| 4 | Dismantling of existing old unserviceable stay assembly complete (demolition of concrete, etc). of street light poles of any size from any descritpion.Note: Excavation and earth work measured seperately. |
| 5 | Dismantling of old existing concrete poles/struts any size including setting aside for reuse within 50 meters |
| 6 | Taking down old unserviceable street light fittings any type including corroded GI Bracket along with clamps, bolts, nuts etc from pole removing the materials to store for taking credit. |
| 7 | Supply and fix Hot dip galvanised iron octogonal pole of height 9 mtrs for street light fitting minimum galvanising of 70 microns, top 70 mm, bottom 155 mm and 3 mm sheet thickness in single section without any weld joints with square base plate of minimum dimensions 225x225x12 mm with foundation bolts, single arm GI bracket of 900x1000 mm for mounting one or two light fittings, backelite sheet with one 6 A SP MCB and 16 mm stud type connectors - 04 nos inside the pole at the door opening for cable connections, common templates minimum 01 for each 15 poles all fixed and bolted on and including suitable PCC pedestal as per manufacturers recommendations and specifications all as directed (for street/security lights)Mast and pole shaft shall be as per BSEN 10025,IS 5986, ASTM A572Make of pole: Bajaj/Jindal/Crompton/Shubham |
| 8 | Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core all as directed by Engineer-in-charge. |
| 9 | Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core all as directed by Engineer-in-charge. |
| 10 | Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 2 core all as directed by Engineer-in-charge. |
| 11 | Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for laying & removing of cable any sizes and getting out in hard/dense soil/ laterite rock all as specified. |
| 12 | Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for laying & removing of cable any sizes and getting out in soft disintegreted rock/ laterite rock all as specified. |
| 13 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata . |
| 14 | Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above from the starting point. |
| 15 | PCC 1:4:8 type D-2 ( Using 40 mm graded crushed stone aggregate ) as in mass concrete for foundation filling of poles all as required at site and directed. |
| 16 | PCC 1:3:6 type C-2 ( Using 40 mm graded crushed stone aggregate ) as in mass concrete for foundation filling of stays and coping of poles insluding necessary form work all as required at site and directed. |
| 17 | Supply and laying DWC Cable duct/Pipe of outer dia of 40mm and inner dia of 39.3/37 mm polyethylene (PE) with smooth internal and profiled external surface for non pressure for undergound cable suitable for 25 sqmm to 16 sqmm cable including bend, connected coupler fittings for jointing etc complete all asspecified and directed by Engr in Charge. Make: Supreme, Extrel, Finolex or quivalent as approved by GE. |
| 18 | Supply and fixing New generation energy saving and environmental friendly long life LED street light fitting 70 W made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07. |
| 19 | Supply and fixing New generation energy saving and environmental friendly long life LED street light fitting 100 W made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07. |
| 20 | Removing corroded GI Bracket along with clamps, bolts, nuts etc from pole, supply and fix new GI bracket made out of 40 mm dia GI pipe length 1.20m long bent to an angle of 1350 and reduce/increase at the end to match with the street light including suitable 02 set of clamps with nut ,bolts ,and washer for fixing of light to pole all as specified and directed. |
| 21 | Supply & fixing pole mounting junction box (looping box) for street light for 3 phase 4 wire system with internal size 240 x 130 x 110 mm comprising of PVC connector and one MCB SP 6 amps including mounting arrangement . Make- Sintex/Hansel |
| 22 | M&L for 2.5 Sqmm 2 core FRLS, PVC insulated copper conductor cable unsheathed 1100 volts grade multi stranded including earth wire from street light fitting to looping box on pole through the GI tubing bracket complete all as specified and directed. |
| 23 | S&F Rigid non metallic PVC conduit 20mm dia inlcuding necessary accessories for fixing along with poles from looping box to street light fitting for protection of copper cable |
| 24 | S&F MCB SP 06 to 32 Amp 240 volts,50Hz,Breaking Capacity 10 KA complete all as specified and directed. |
| 25 | S&F MCB TPN FP 40A to 100A 415 volts,50Hz, Breaking Capacity 10 KA complete all as specified and directed. |
| 26 | Supply and Fix Street light timer panel with range of 6 kW to 12 kW & contactor rating 32 A TP and MCB rating 40A with Astronomical switch for SLP, Confirming to IS /IEC 61439 & 60529, Provided with protection degree IP54, Extended wide band coil, FRLS (Fire retardant low smoke) internal wiring, In-built short-circuit protection, class H insulation |
| 27 | M & L for cutting existing Road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm aggregate thickness of concrete is 150mm complete all as specified and directed. |
| 28 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 16 sq mm. |
| 29 | Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (Epoxy Based) and accessories suitable for 3½ core XLPE armoured Al conductor cable of size 25 sq mm. |
| 30 | Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat,one under coat and one finshing coat of paint Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender