Tender For special Rep/Repl Of Old Hpsv/Hpmv/Cfl T5 Street Light With New Led Street Light Fitting And providing Of Solar Street Light For Internal Road/Hostel Area And Pronv Of 02Xhigh Mast Light At Aps And 2Asdat Mil Stn Beas Under Ge Kapurthala.
Tender Overview
Project Description
Tender for special Rep/Repl Of Old Hpsv/Hpmv/Cfl T5 Street Light With New Led Street Light Fitting And providing Of Solar Street Light For Internal Road/Hostel Area And Pronv Of 02Xhigh Mast Light At Aps And 2Asdat Mil Stn Beas Under Ge Kapurthala.
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Garrison Engineer Kapurthala Name of Work : Spl rep/repl of old HPSV/HPMV/CFL T5 street light with new LED street light fitting and prov of solar street light for internal road/hostel area and pronv of 02xhigh mast light at APS and 2ASDat Mil Stn Beas under GE Kapurthala. Contract No : GE KPT- /2026-27 Bidder Name : SCHEDULE OF WORKS(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # S.No Description of work Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | S&F of all-in-one solar street light of 25 watt made up of metallic body, IP65 (120 Lm/W) with an in-built battery of capacity 24 Ah connected with poly solar PV panel of 60 Wp size mounted on top of the pole and mounting clamp, inbuilt MPPT charge controller and PIR motion sensor for motion detection with connector, pin and 1.0 sqmm twin core sheathed copper cable for connection and accessories. Note:- 20 years performance warranty on solar panel SPV Module. |
| 3 | S&F of 6m GI pole of 80 mm bore dia with grouting rods, and necessary hardware including PCC of size 40x40x90 cm in cement concrete 1:3:6 (20mm graded stone aggregate), including necessary excavation in any soil, returning, filling in and removal of surplus soil upto a distance of 50m and all as specified and as directed. |
| 4 | Taking down old unserviceable HPSV/ HPMV/ CFL T5 street light fitting and S&F of energy saving LED street light fitting 35 watt, 230 V AC outdoor type, with PDC aluminium body and toughened glass visor fitted in frame, separately driver compartment provided, secondary optical lens for superior light distribution efficiency >105Lm/W, CCT 5700K, IP66, input voltage from 120-270 V power factor above 0.95 complete with driver, lamp, suitable for 32/40/50 mm dia bracket with impact resistant complete all as specified and directed by Engineer-in-Charge. Note:- Fixing of new street lights will included any nipple or other fixtures required to fix the new lights on the existing brackets at no extra cost.(Note : Fixing of new street lights will included any nipple or other fixtures required to fix the new lights on the existing brackets at no extra cost). |
| 5 | - ditto - all as per item No 3 above here-in-before but LED street light fitting 60 watt complete all as specified and directed. |
| 6 | Taking out old unserviceable underground cable from trenches/ floors/road/wall /pipe/ pole LT cable of any size/ description. |
| 7 | Taking down/ dismantling of old unserviceable ACSR conductor from overhead lines / LT Poles of any size and description. |
| 8 | Supplying, laying, jointing and testing under ground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 vols grade cross sectional area 50 Sqmm 3.5 core laid in trences, in floor, in duct, through pipes or along the pole including taking down old one complete all as specified and directed by Engr-in-Charge.Note:- The quoted rate deemed to be included supply and fixing of aluminum thimbles/Lugs crimping type of size 10 to 35 Sq mm as per site requirement for connected UG Cable to LT Panel / Junction box etc; |
| 9 | - ditto - all as per item No 7 but cross sectional area 35 Sqmm 3.5 core. |
| 10 | - ditto - all as per item No 7 but cross sectional area 25 Sqmm 4 core. |
| 11 | - ditto - all as per item No 7 but cross sectional area 16 Sqmm 4 core. |
| 12 | - ditto - all as per item No 7 but cross sectional area 10 Sqmm 4 core. |
| 13 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for foundation of poles/ stays/ laying of cables etc and getting out including trimming of sides of trenches complete all as specified and directed. |
| 14 | Returning, filling the soft / loose soil including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed. |
| 15 | Removing of surplus excavated soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 16 | M&L for sand cushioning to under ground cable with a layer of sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. |
| 17 | M&L for brick protection using old size sub class ‘B’ bricks, laid flat, dry adjacent to each other laid length wise perpendicular to the axis of cable complete all as specified and directed. |
| 18 | M&L for steel tubing GI light grade 50 mm dia for cable protection, passing under road/floor or for fixing to poles/walls all as specified and directed. |
| 19 | M&L for steel tubing GI light grade 40 mm dia for cable protection, passing under road/floor or for fixing to poles/walls all as specified and directed. |
| 20 | Supplying and fabricating erecting LT panel outdoor type CPRI approved double door totally enclosed weather and vermin proof suitably ventilated 415 Volts 50 cycles, AC supply factory made fully compartmentalized made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of angle iron/flat iron frame work/ support required civil works, excavation & earth work, PCC foundation etc, installation, testing & commissioning suitable for control panel for automatic operation of high mast lights with including the following :-(a) Copper bus bar of capacity 350 Amps for phase and Neutral. (b) Combined Voltmeter & Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)Incoming:- (i) MCCB TPN 32 Amps, 10 KA 415 Volts 4 pole (Thermal Magnatic adjustable range - 01 No Outgoing:- (i) MCB 4 pole 06-25 Amps 10 KA, 415 Volts (adjustable thermal and magnatic type70% to 100%) - 02 Nos (ii) Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder programmable (iii) Forward/reverse operation switch - 01 No |
| 21 | M&L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 . |
| 22 | S&F of street light fitting bracket, 1.5 metre long made out of galvanised iron pipe of 40 mm dia pipe of thickness 3.2 mm fixed on top with bolts of existing pole dia size light grade complete with nut, bolts, washer etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as specified and directed for hot dip galvanised single plain arm bracket 1000 mm over hang with 48.3 mm outer complete all as specified. |
| 23 | S&F of junction box factory made weather proof size 300mmx250mmx 150mm made of PVC inculded 25mmx6mm aluminium TPN bus bars & 01 MCB 6 Amps for controlled one No's of LED Lights complete all as specifed and directred |
| 24 | S&F in replacement of time light distribution board analog time switch 230 volt three phase of 16 Amps rating with contactor fixed inside steel enclosure box and fixed to pole/LT Panel including MCB, selector switch, RYB indicator, cable glands, clamps, nuts, bolts and washers or fabrication of GI stand above for mounting Timer light box of minimum height 2 ft above ground level etc; complete all as specified and directed. |
| 25 | M&L for service wire and supply and fixing service wire copper conductor weather Proof 1.5 Sqmm 3 core including 15 mm dia PVC conduit with clamps, nuts, bolts and srew complete all as specified and directed. |
| 26 | S&F of telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 32 mm polythylene including coupler & Bend with smoooth internal and profiled external surface for non pressure under ground cable or protecting cable connecting to junction box complete all as specified. |
| 27 | M&L for supply installation testing commissioning of High galvanized mast light system raising and lowering type of 15 mtr/ 16 mtr heigh, suitable for 225 km/ hr wind speed (wind velocity as per IS 875 part 3), complete mast shall be in two section , hot dip galvanised, inside and outside in single dip. There shall be only one longitudinal seem weld section and no circumferential weld. It shall also include accessories for high mast including head frame 2-post suspension system with steel wire rope not less than 5 mm dia double drum winch, Galvanised lantern carriage arrangement suitable for upto 6 luminaries symmetrically, lighting finial & integral power tool for raising and lowering operation of the high mast. Fittings and accessories as under :-(a) Length of bottom section - 8.250 Mtrs (b) Length of top section -8.250 Mtrs (c) Base dia - 360 mm (approx) (d) Top dia -150 mm (approx) (e) Size of opening and door at base -1200x250 (close fitting door with suitable reinforcement to avoid Buckling at base of mast) (f ) Lighting protection finial -G. single spike of length 1200 mm (g) Construction of suitable RCC foundation including foundation bolts maufactured from special alloy with nuts, washer, anchor plate& templates etc all materials & labour complete all as per manufacturer specification/ recommendation.(h) Supply, installation and commissioning of automatic control panel for switch ON/OFF high mast light and raising/lowering of high mast. Control Panel consisting of Astronomical time switch (Having facility for operation of partial load for full night and the balance / full load for part night to derive energy saving) incoming/outgoing MCCBs, and contactors of suitable capacity including provision for by pass arrangement.(j) Twin dome Aviation obstruction light with suitable lamp to be provided as per manufacturer specification.(k) Lightening arrestor with lightening conductor to be provided as per manufacturer specification.(l) Lantern Carriage:- Lantern carriage ring with class BMS pipe/tube having sleeve on carriage ring 535 mm (ID) dia suitable to mount 06 Nos of lentern fitting symetrically -01 Nos.(m) Winch :- Winch double drum type having operating speed 180 RPM and gear ratio 53 : 1 working operating manually/electrically with stainless steel wire rope 6mm dia too point suspension system including timble copper Talurit capacity 500 Kgs (per Drum) make lubrication arrangement self lubricant in permanent oil both bath type SAE-90/140 or equivalent each Job -01 No.(n) Stainless steel wire rope:- Diameter of SS rope 6 mm, AISI 304 grade, construction of SS rope 7/19 , stainless steel of centre core material DIN 3060, 3 Nos rope of 6 mm for Lantern Carriage, 2 Nos of 6 mm for Double drum Winch, breaking load capcity of SS wire rope are 2350 Kgs per SS rope.(o) Trailing Cable :- Copper conductor cable PVC sheathed 1100 volt grade of size 4.00 Sq mm PVC insulataed from electrical box to street light fittings separately for nine fittings each Job -01 No.(p) Push button control 415 Volt 3 phase 50HZ 1440 RPM single speed 1100 watt torque lifting capacity 750 Kgs adjustable mechanically tripping device complete all as specified.(q) Power Tool:_ 1 HP / 1.5 HP integral model, single speed, reversible 415 volts/240 Volts with mechanical tripping facility. |
| 28 | S&F of LED flood light fitting 120 watt for high mast energy saving, environment friendly, long life with pressure die cast housing IP 66 protection, efficient high output emitter LED for better distribution including clamp on bracket suitable for fixing of LED flood light fitting including necessary connection complete all as directed. |
| 29 | Supplying and install test and comprising of factory made powder coated cubical outdoor LT feeder pillar box of size 900 x 750 x 300 mm confirming to IP-65, CPRI approved complete weather proof and vermin proof and the shell of 3.15 mm thick MS sheet with partitions and switch enclosure doors of 2 mm MS sheet with minimum clearance of 750 mm and canopy made out of 3.15 mm thick MS sheet all as per IS shall be available inside for easy access and working condition fixed on angle iron frame 50 x 50 x 6mm. Mounted on brick masonry pillars with a clearance of atleast 0.45 mtrs above GL on 100mm thick appron of PCC 1:4:8 type D-2 provided 1.0 mtr all around with a slight outward slope to avoid stagnation of water, marking to indentify incoming and outgoing circuits and earthing pillar box at two points out door feeder pillar box comprising of following:-(a) MCCB 63 Amp,4 pole 25 KA ,415 volt ICU 100% ICS with thermal based release = 03 Nos (01 Incomer, 02 outgoing)(b) Timer switch Analog outdoor type factory made powder coated all along internal and external surfaces, weather proof, dust and water proof with I P 55 protection, consisting of 01 No AC contactor 3 pahse 16 Amp capacity 10 KA, one digital Timer switch with 16 Amp three Nos MCB SP 10 Amp 10 KA having both auto manual and by pass system - 01 No mounted on existing panel with suitbale size clamps complete all as specified and directed. (c) Reversing starter capacity 2 HP/1.5 KW with contactor size 18, overload relay range 2.5-4 Amp. |
| 30 | S&F of GI pipe light grade 80 mm bore for cable protection fixed to pole/along wall/floor/under road etc complete all as specified and directed. Note:- Clamps nuts & bolts etc; shall be measured and paid for separately under appropriate items of sch 'A' Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender