Tender For Improvement Of Grounding Valves Of Lt Installations And Certain Connected Items Of Zone-Ii Under Ge (A) Jaisalmer
Tender Value
49 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
7 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Improvement Of Grounding Valves Of Lt Installations And Certain Connected Items Of Zone-Ii Under Ge (A) Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | M&L for testing of existing earthing in E/M installation using with appropriate earth resitance tester, spike and wire, recording of earth test results in register submitting the same to the department complete all as directed at site. |
| 2 | M & L in repair bore earthing not less than 250 mm dia 12 meter deep filled with black soil up to 6 meter from bottom complete with 25 mm dia copper bonded steel of length 6 mtr and copper thickness not lessthan 250 micron at bottom burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 and provision of funnel with wire mesh for watering arrangement and testing on completion and including dismantling of old existiing earthing of any description complete all as specified and directed by Engineer-in-charge. Note:Test report of copper bonded steel rod to be submitted by contractor |
| 3 | M & L in repair bore earthing not less than 250 mm dia 12 meter deep filled with black soil up to 6 meter from bottom complete with galvanized iron pipe 40 mm bore medium grade 6 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32x6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 and provision of funnel with wire mesh for watering arrangement and testing on completion and including dismantling of old existiing earthing of any description complete all as specified and directed by Engineer-in-charge. |
| 4 | M & L in repair bore earthing not less than 250 mm dia 12 meter deep filled with black soil up to 6 meter from bottom complete with copper pipe 40 mm bore of thickness 2 mm and 6 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to copper strip 25X4 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 and provision of funnel with wire mesh for watering arrangement and testing on completion and including dismantling of old existiing earthing of any description complete all as specified and directed by Engineer-in-charge. |
| 5 | M&L in repair galvaniased iron (GI) strip 32mm x 6 mm buried in ground/ Passed through pipe incuding connected by means of exothermic brazing, nuts and bolts where required complete all as specified and directed by Engineer-in-charge. |
| 6 | M&L in repair copper strip 25x4 mm buried in ground/ Passed through pipe incuding connected by means of exothermic brazing, nuts and bolts where required complete all as specified and directed by Engineer-in-charge. |
| 7 | M&L for refixing of serviceable GI earth strip of any size retrived from site complete all as specified and directed by Engineer-in-charge. |
| 8 | Supply and fixing in repair GI Pipe light grade, 40mm dia , galvanized, with all fittings complete all as specified and directed by Engineer-in-charge. |
| 9 | Supply and fixing in repair GI Pipe medium grade, 40mm dia , galvanized, with all fittings complete all as specified and directed by Engineer-in-charge. |
| 10 | Supply and fixing in repair GI Pipe light grade, 50mm dia , galvanized, with all fittings complete all as specified and directed by Engineer-in-charge. |
| 11 | Supply and fixing in repair GI Pipe light grade, 80mm dia , galvanized, with all fittings complete all as specified and directed by Engineer-in-charge. |
| 12 | S&F in repair GI Tubes, of 20mm bore size,medium grade ,galvanised including fittings ,fixed to wall/pole/ceiling or laid in floors or under road for watering of earth pits complete all as specified and directed by Engineer-in-charge. |
| 13 | S&F in repair Gun-metal, globe or gate valves suitable for 20mm dia GI Pipe, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-charge. |
| 14 | S&F in repair Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-charge. |
| 15 | Material and labour for attending external electrification UPTO 0.433 KV breakdowns and external LT no light complaints and allied works by providing one skilled electrician and one helper round the clock including sundays and holidays having sound in knowledge of 0.433 KV overehead and under grounds LT netwrok system and breakdown/no light complaints supply shall be attended so as to rectify the faluted system and complete restoration all as specified and directed by Engr-In-Charge.During breakdown supply, the technician shall coordinate/laison with substation operator/JE/AGE for replacement of parts and services as required.Note:-(i) The rate against the above mentioned item is deemed for cost of labour,transportation,tools such as clamp meter,plier,tester,test lamp,screw driver,hacksaw,hammer,spanner and other tools reqired to attend complaints and safety equipments folding ladder,insulation tapes misc items like insulation tape for repair work.(ii) Contractor shall provide one experienced electrician and one helper per shift to attend the complaints round the clock and during emergency complaints.(iii) Quoated rate is deemed to be inclusive of tools mentioned in ser no 01 failing may effect penal recovery of Rs 10000/- will be made once in entire contract period. |
| 16 | (iv) Items required such as cable,joints and other switch gear,lugs etc will be measured and paid separarely.Quoated rate is inclusive of removing of cable loop from the attended area towards completion of electrical defect.The contractors staff shall attend no light complaints for different areas under Zone-II of GE(A) Jaisalmer.(iv) The LT break down/no light complaint shall be shall be attendwithin 1 hrs after receipt of complaint frpm any mode/agency.(v) The contractor's representative will report to concerned JE E/M to collect the list of breakdowns and will submit the completion report to the JE E/M.(vi) Before commencement of any attending complaint the contractor's staff shall get prior permission for shutdown from JE/AGE/GE. In case the breakdown has not been restored within the specified time limit, an amount of Rs 500/- per hr will be recovered from the contarctor during RAR / Final Bill. (vii)Register of breakdown/no light complaints should be prepared by the technician and details of repair to be updated in the register after completion of every work duly signed by user or JE E/M. Please Enable Macros to View BoQ information |
| 17 | (iv) Items required such as cable,joints and other switch gear,lugs etc will be measured and paid separarely.Quoated rate is inclusive of removing of cable loop from the attended area towards completion of electrical defect.The contractors staff shall attend no light complaints for different areas under Zone-II of GE(A) Jaisalmer.(iv) The LT break down/no light complaint shall be shall be attendwithin 1 hrs after receipt of complaint frpm any mode/agency.(v) The contractor's representative will report to concerned JE E/M to collect the list of breakdowns and will submit the completion report to the JE E/M.(vi) Before commencement of any attending complaint the contractor's staff shall get prior permission for shutdown from JE/AGE/GE. In case the breakdown has not been restored within the specified time limit, an amount of Rs 500/- per hr will be recovered from the contarctor during RAR / Final Bill. (vii)Register of breakdown/no light complaints should be prepared by the technician and details of repair to be updated in the register after completion of every work duly signed by user or JE E/M. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender