Defence Statutory Bodies & Commissions/Committees Closing in 14 days TDR #57501015

Tender For Special Repairs To Rewiring At Twin Hanger Alongwith Annexes And Special Repairs/ Replacement To Unserviceable Earthing Pits At Various Locations At Afa Hyderabad.

Issued by Statutory Bodies & Commissions/Committees · Medchal Malkajgiri, Telangana
Tender Value
47.75 Lakhs
Estimated cost
Bid Submission
02 Oct 2026
14 days left
EMD
95500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Medchal Malkajgiri → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repairs To Rewiring At Twin Hanger Alongwith Annexes And Special Repairs/ Replacement To Unserviceable Earthing Pits At Various Locations At Afa Hyderabad.

BOQ

Name of Work:- SPECIAL REPAIRS TO REWIRING AT TWIN HANGER ALONGWITH ANNEXES AND SPECIAL REPAIRS/ REPLACEMENT TO UNSERVICEABLE EARTHING PITS AT VARIOUS LOCATIONS AT AFA HYDERABAD.
Sl. No. Item Description
1Taking down old, unsv aluminium point wiring (light, fan, socket or power) complete, incl fixture & fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, air circulator fans etc. removing materials to store for keeping in safe custody for reuse or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and as directed & to the entire satisfaction of Engr-In-Charge.
2Taking down old sub-main wiring including fixture & fittings etc. removing materials to store for keeping in safe custody or for taking credit & making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-In-Charge.
3Disconnecting/dismantling of old existing un serviceable DB's any type/way 240/415 Volts with their old/un serviceable burnt MCCB/MCB's etc. complete all as specified and directed by Engr-In-Charge.
4Refixing of Air Circulator Fans any type / rating / wattage dismantled against Item Sl No 1 above after dusting, cleaning, making necessary electrical connections & testing complete all as specified & as directed.
5Refixing of High Bay Lights any type / rating / wattage dismantled against Item Sl No 1 above after dusting, cleaning, making necessary electrical connections & testing complete all as specified & as directed.
6Refixing of 2' x 2' Recess Lights any type / rating / wattage dismantled against Item Sl No 1 above after dusting, cleaning, making necessary electrical connections & testing complete all as specified & as directed. NOTE for Item Nos 1 to 6 : Cost of making good the disturbed surfaces is deemed to be included in the unit quote rates.
7M & L for surface flame proof point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including stove enamelled steel conduit of size not less than 20 mm dia with all fittings and accessories ISI marked, ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) & incl fixing of flame proof Metal Junction / Inspection boxes (if any) with including cutting chases (if any) for conduits & sinkings for modular boxes, necessary fixing arrangements & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of cable : Havells/Polycab/Finolex/KEI. Make of Steel Conduit : ISI Marked(a) One Light point etc. controlled by one flame proof switch. Please Enable Macros to View BoQ information
8M & L for surface flame proof point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLSH cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including stove enamelled steel conduit of size not less than 20 mm dia with all fittings and accessories ISI marked, ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLSH, ISI marked as earth continuity conductor (green in colour) & incl fixing of flame proof Metal Junction / Inspection boxes (if any) with including cutting chases (if any) for conduits & sinkings for modular boxes, necessary fixing arrangements & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of cable : Havells/Polycab/Finolex/KEI. Make of Steel Conduit : ISI Marked(a) One Light point etc. controlled by one flame proof switch. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57501015
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.75 Lakhs
LAST DATE 02-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repairs To Rewiring At Twin Hanger Alongwith Annexes And Special Repairs/ Replacement To Unserviceable Earthing Pits At Various Locations At Afa Hyderabad.
Basic Detail
Tender No 8745/E8
Bidding Type Tender
Location
City Medchal Malkajgiri
State Telangana
Key Dates
Publish Date 12 Sep 2026
Submission Date 02 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 47.75 Lakhs
Tender Fee 500
EMD 95500
Exemption Available
Document List
2c597a05-2040-441a-8b2f-dbe5c0092be8.html
BOQ_884675.xls
Tendernotice_1 (10).pdf
TENDERPAGES8745.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 02, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

2c597a05-2040-441a-8b2f-dbe5c0092be8.html

xls

BOQ_884675.xls

pdf

Tendernotice_1 (10).pdf

pdf

TENDERPAGES8745.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders