Public Administrative Department Trust & NGO Closing in 4 days TDR #57490899

Tender For Rate Contract For Supply Of Led Lights Of Different Ratings For A Period Of Three (03) Months To Smvdsb, F.O.R. Engineering Store, Banganga, Katra. , Supply Of Led Lights Of Different Ratings , Led Tube Fitting 1Ft 4 W To 5 W, Aluminium Body, S

Issued by Trust & NGO · katra, Jammu and Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Sep 2026
4 days left
EMD
60000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
katra → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Rate Contract For Supply Of Led Lights Of Different Ratings For A Period Of Three (03) Months To Smvdsb, F.O.R. Engineering Store, Banganga, Katra. - 1 Supply Of Led Lights Of Different Ratings 2 Led Tube Fitting 1Ft 4 W To 5 W, Aluminium Body, System Lumen Output≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Pf≥0.90, Surge 2.5Kv, Warranty : Minimum – 2 Years 3 Led Tube Fitting 2Ft 10 W To 12 W, Aluminium Body, System Lumen Output≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Pf≥0.90, Surge 2.5Kv, Warranty : Minimum - 2Years 4 Led Tube Fitting 4Ft 18W To 20 W, System Lumen Output≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Pf≥0.90, Surge 2.5Kv, Warranty : Minimum - 2 Years 5 Led Surface Mounted Ceiling Light Fitting 12W Round Pressure Die Cast Aluminium Housing Only, System Lumen Output ≥ 100-120Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Years. 6 Led Recess Mounted Concealed Light 12-20 W Round, (Dia 6\) Pressure Die Cast Aluminium Housing Only, System Lumen Output ≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv, Pf≥0.90, Ip20.. Warranty Minimum - 2 Yrs. 7 Led Ceiling Light 8/9 Watt Recess Mounted (Concealed), Pressure Die Cast Aluminium Housing Only System Lumen Output ≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv , Pf≥0.90, Ip20.. Warranty Minimum - 2 Yrs. 8 Led Ceiling Light 5/6 Watt Recess Mounted (Concealed), Pressure Die Cast Aluminium Housing Only System Lumen Output ≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Yrs. 9 Led Recessed Mounted Panel 36 Watt 2Ft. X 2 Ft., System Lumen Output:≥ 100-120Lm/W, Cct: 6500°K, Cri≥ 80, Thd≤30%, Surge 2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Years 10 Led Recessed Mounted Panel 36 Watt 2Ft. X 2 Ft., (Warm White) System Lumen Output:≥ 100-120Lm/W, Cct: 3000°K, Cri≥ 80, Thd≤30%, Surge 2.5Kv, Pf≥0.90, Ip20.Warranty: Minimum - 2 Years 11 Led Surface Mounted Panel 36 Watt 2Ft. X 2 Ft., System Lumenoutput:≥ 100-120Lm/W, Cct: 6500°K, Cri≥ 80, Thd≤30%, Surge2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Years 12 Led Lamp 0.5 Watt, Coloured (Red, Blue, Green, Yellow, Orangeand Pink) 13 Led Lamp 9 W To 10 Watt, System Lumen Output ≥ 80-100Lm/W,Cct: 6500°K, Cri ≥ 80, Warranty: Minimum 2 Years 14 Led Lamp 15 W To 17 Watt, System Lumen Output ≥ 80-100Lm/W,Cct: 6500°K, Cri ≥ 80, Warranty: Minimum 2 Years 15 Led Lamp 5 W To 7 Watt, System Lumen Output ≥ 80-100Lm/W, Cct:6500°K, Cri ≥ 80, Warranty: Minimum 2 Years 16 Led Street Light 70/72 Watt, Pressure Die Cast Aluminium Housingonly, System Lumen Output:≥ 120Lm/W, Cct:5700-6500°K, Cri≥ 80,Thd≤10%, Surge 4Kv, Pf≥0.95, Ip66, Warranty Minimum - 2 Yrs 17 Led Flood Light 60/70 Watt, Pressure Die Cast Aluminium Housingonly, System Lumen Output:≥ 120Lm/W, Cct: 5700=6500°K, Cri≥80, Sdcm≤5, Thd≤10%, Surge 4Kv, Pf≥0.90, Ip66. Warrantyminimum - 2 Years 18 Led Flood Light 140-150 Watt, Pressure Die Cast Aluminum Housingonly, System Lumen Output:≥ 120Lm/W, Cct: 5700=6500°K, Cri≥80, Sdcm≤5, Thd≤10%, Surge 4Kv, Pf≥0.90, Ip66. Warrantyminimum - 2 Years 19 Led Recess Mounted Concealed Light 10 W - 12 W Round, Pressuredie Cast Aluminium Housing Only, System Lumen Output ≥100Lm/W,Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv,Pf≥0.90, Ip20. Warranty Minimum - 2 Years

BOQ

Name of Work:- Rate Contract for Supply of LED Lights of different ratings for a period of three (03) months to SMVDSB, F.O.R. Engineering Store, Banganga, Katra.
Sl. No. Item Description
1Supply of LED Lights of different ratings
2LED Tube Fitting 1ft 4 W to 5 W, Aluminium Body, System Lumen Output≥100lm/w, CCT: 6500°K, CRI≥ 80, SDCM≤5, PF≥0.90, Surge 2.5KV, Warranty : Minimum – 2 Years
3LED Tube Fitting 2ft 10 W to 12 W, Aluminium Body, System Lumen Output≥100lm/w, CCT: 6500°K, CRI≥ 80, SDCM≤5, PF≥0.90, Surge 2.5KV, Warranty : Minimum - 2Years
4LED Tube Fitting 4ft 18W to 20 W, System Lumen Output≥100lm/w, CCT: 6500°K, CRI≥ 80, SDCM≤5, PF≥0.90, Surge 2.5KV, Warranty : Minimum - 2 Years
5LED Surface Mounted Ceiling Light Fitting 12W Round Pressure Die Cast Aluminium Housing Only, System Lumen Output ≥ 100-120lm/W, CCT: 6500°K, CRI≥ 80, SDCM≤5, THD≤10%, Surge 2.5KV, PF≥0.90, IP20. Warranty Minimum - 2 Years.
6LED Recess Mounted Concealed Light 12-20 W Round, (Dia 6\\") Pressure Die Cast Aluminium Housing Only, System Lumen Output ≥100lm/W, CCT: 6500°K, CRI≥ 80, SDCM≤5, THD≤10%, Surge 2.5KV, PF≥0.90, IP20.. Warranty Minimum - 2 Yrs.
7LED Ceiling Light 8/9 Watt Recess Mounted (Concealed), Pressure Die Cast Aluminium Housing Only System Lumen Output ≥100lm/W, CCT: 6500°K, CRI≥ 80, SDCM≤5, THD≤10%, Surge 2.5KV , PF≥0.90, IP20.. Warranty Minimum - 2 Yrs.
8LED Ceiling Light 5/6 Watt Recess Mounted (Concealed), Pressure Die Cast Aluminium Housing Only System Lumen Output ≥100lm/W, CCT: 6500°K, CRI≥ 80, SDCM≤5, THD≤10%, Surge 2.5KV, PF≥0.90, IP20. Warranty Minimum - 2 Yrs.
9LED Recessed Mounted Panel 36 watt 2ft. x 2 ft., System Lumen Output:≥ 100-120lm/W, CCT: 6500°K, CRI≥ 80, THD≤30%, Surge 2.5KV, PF≥0.90, IP20. Warranty Minimum - 2 Years
10LED Recessed Mounted Panel 36 watt 2ft. x 2 ft., (Warm White) System Lumen Output:≥ 100-120lm/W, CCT: 3000°K, CRI≥ 80, THD≤30%, Surge 2.5KV, PF≥0.90, IP20.Warranty: Minimum - 2 Years
11LED Surface Mounted Panel 36 watt 2ft. x 2 ft., System LumenOutput:≥ 100-120lm/W, CCT: 6500°K, CRI≥ 80, THD≤30%, Surge2.5KV, PF≥0.90, IP20. Warranty Minimum - 2 Years
12LED Lamp 0.5 Watt, Coloured (Red, Blue, Green, Yellow, Orangeand Pink)
13LED Lamp 9 W to 10 Watt, System Lumen Output ≥ 80-100lm/w,CCT: 6500°K, CRI ≥ 80, Warranty: Minimum 2 Years
14LED Lamp 15 W to 17 Watt, System Lumen Output ≥ 80-100lm/w,CCT: 6500°K, CRI ≥ 80, Warranty: Minimum 2 Years
15LED Lamp 5 W to 7 Watt, System Lumen Output ≥ 80-100lm/w, CCT:6500°K, CRI ≥ 80, Warranty: Minimum 2 Years
16LED Street Light 70/72 Watt, Pressure Die Cast Aluminium HousingOnly, System Lumen Output:≥ 120lm/W, CCT:5700-6500°K, CRI≥ 80,THD≤10%, Surge 4KV, PF≥0.95, IP66, Warranty Minimum - 2 Yrs
17LED Flood Light 60/70 Watt, Pressure Die Cast Aluminium HousingOnly, System Lumen Output:≥ 120lm/W, CCT: 5700=6500°K, CRI≥80, SDCM≤5, THD≤10%, Surge 4KV, PF≥0.90, IP66. WarrantyMinimum - 2 Years
18LED Flood Light 140-150 Watt, Pressure Die Cast Aluminum HousingOnly, System Lumen Output:≥ 120lm/W, CCT: 5700=6500°K, CRI≥80, SDCM≤5, THD≤10%, Surge 4KV, PF≥0.90, IP66. WarrantyMinimum - 2 Years
19LED Recess Mounted Concealed Light 10 W - 12 W Round, PressureDie Cast Aluminium Housing Only, System Lumen Output ≥100lm/W,CCT: 6500°K, CRI≥ 80, SDCM≤5, THD≤10%, Surge 2.5KV,PF≥0.90, IP20. Warranty Minimum - 2 Years
20LED Surface Mounted Light 18 W - 20 W Round, Pressure Die CastAluminium Housing Only, System Lumen Output ≥100lm/W, CCT:6500°K, CRI≥ 80, SDCM≤5, THD≤10%, Surge 2.5KV, PF≥0.90,IP20. Warranty Minimum - 2 Years Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57490899
AUTHORITY Trust & NGO
TENDER VALUE Ref. Documents
LAST DATE 19-09-2026
Authority
Authority Name Shri Mata Vaishno Devi Shrine Board
Work Description Tender For Rate Contract For Supply Of Led Lights Of Different Ratings For A Period Of Three (03) Months To Smvdsb, F.O.R. Engineering Store, Banganga, Katra. - 1 Supply Of Led Lights Of Different Ratings 2 Led Tube Fitting 1Ft 4 W To 5 W, Aluminium Body, System Lumen Output≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Pf≥0.90, Surge 2.5Kv, Warranty : Minimum – 2 Years 3 Led Tube Fitting 2Ft 10 W To 12 W, Aluminium Body, System Lumen Output≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Pf≥0.90, Surge 2.5Kv, Warranty : Minimum - 2Years 4 Led Tube Fitting 4Ft 18W To 20 W, System Lumen Output≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Pf≥0.90, Surge 2.5Kv, Warranty : Minimum - 2 Years 5 Led Surface Mounted Ceiling Light Fitting 12W Round Pressure Die Cast Aluminium Housing Only, System Lumen Output ≥ 100-120Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Years. 6 Led Recess Mounted Concealed Light 12-20 W Round, (Dia 6\) Pressure Die Cast Aluminium Housing Only, System Lumen Output ≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv, Pf≥0.90, Ip20.. Warranty Minimum - 2 Yrs. 7 Led Ceiling Light 8/9 Watt Recess Mounted (Concealed), Pressure Die Cast Aluminium Housing Only System Lumen Output ≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv , Pf≥0.90, Ip20.. Warranty Minimum - 2 Yrs. 8 Led Ceiling Light 5/6 Watt Recess Mounted (Concealed), Pressure Die Cast Aluminium Housing Only System Lumen Output ≥100Lm/W, Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Yrs. 9 Led Recessed Mounted Panel 36 Watt 2Ft. X 2 Ft., System Lumen Output:≥ 100-120Lm/W, Cct: 6500°K, Cri≥ 80, Thd≤30%, Surge 2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Years 10 Led Recessed Mounted Panel 36 Watt 2Ft. X 2 Ft., (Warm White) System Lumen Output:≥ 100-120Lm/W, Cct: 3000°K, Cri≥ 80, Thd≤30%, Surge 2.5Kv, Pf≥0.90, Ip20.Warranty: Minimum - 2 Years 11 Led Surface Mounted Panel 36 Watt 2Ft. X 2 Ft., System Lumenoutput:≥ 100-120Lm/W, Cct: 6500°K, Cri≥ 80, Thd≤30%, Surge2.5Kv, Pf≥0.90, Ip20. Warranty Minimum - 2 Years 12 Led Lamp 0.5 Watt, Coloured (Red, Blue, Green, Yellow, Orangeand Pink) 13 Led Lamp 9 W To 10 Watt, System Lumen Output ≥ 80-100Lm/W,Cct: 6500°K, Cri ≥ 80, Warranty: Minimum 2 Years 14 Led Lamp 15 W To 17 Watt, System Lumen Output ≥ 80-100Lm/W,Cct: 6500°K, Cri ≥ 80, Warranty: Minimum 2 Years 15 Led Lamp 5 W To 7 Watt, System Lumen Output ≥ 80-100Lm/W, Cct:6500°K, Cri ≥ 80, Warranty: Minimum 2 Years 16 Led Street Light 70/72 Watt, Pressure Die Cast Aluminium Housingonly, System Lumen Output:≥ 120Lm/W, Cct:5700-6500°K, Cri≥ 80,Thd≤10%, Surge 4Kv, Pf≥0.95, Ip66, Warranty Minimum - 2 Yrs 17 Led Flood Light 60/70 Watt, Pressure Die Cast Aluminium Housingonly, System Lumen Output:≥ 120Lm/W, Cct: 5700=6500°K, Cri≥80, Sdcm≤5, Thd≤10%, Surge 4Kv, Pf≥0.90, Ip66. Warrantyminimum - 2 Years 18 Led Flood Light 140-150 Watt, Pressure Die Cast Aluminum Housingonly, System Lumen Output:≥ 120Lm/W, Cct: 5700=6500°K, Cri≥80, Sdcm≤5, Thd≤10%, Surge 4Kv, Pf≥0.90, Ip66. Warrantyminimum - 2 Years 19 Led Recess Mounted Concealed Light 10 W - 12 W Round, Pressuredie Cast Aluminium Housing Only, System Lumen Output ≥100Lm/W,Cct: 6500°K, Cri≥ 80, Sdcm≤5, Thd≤10%, Surge 2.5Kv,Pf≥0.90, Ip20. Warranty Minimum - 2 Years
Basic Detail
Tender No e-RFIQ No. CO/Pur/Elect/627-III/2121 Dated 12.09.2026
Bidding Type Tender
Location
City katra
State Jammu and Kashmir
Key Dates
Publish Date 12 Sep 2026
Submission Date 19 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 60000
Exemption Not Available
Document List
801c994e-bec9-437f-8318-6195e973ee6e.html
BOQ_1094627.xls
Tendernotice_1 (19).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

801c994e-bec9-437f-8318-6195e973ee6e.html

xls

BOQ_1094627.xls

pdf

Tendernotice_1 (19).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders