Tender For Repair/Maint Of Internal Wiring, Repair To Ceiling Fans, Geyser, Ac Etc And Connected Assets, External Electric Supply Installation, Oh Lines, Lt Cable, Street Lights, Various Type Of External Lights, Dg Sets & Standby Power Supply At Muza
Tender Overview
Project Description
Tender for Repair/Maint Of Internal Wiring, Repair To Ceiling Fans, Geyser, Ac Etc And Connected Assets, External Electric Supply Installation, Oh Lines, Lt Cable, Street Lights, Various Type Of External Lights, Dg Sets & Standby Power Supply At Muzaffarpur Under Ge Danapur Cantt
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminium point wiring (Light,fan,socket or power) complete fitting such as switches, ceiling rose, regulator, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, etc. all as specified and directed. |
| 2 | M&L light fan point controlled by one switch with PVC insulated, unsheathed, multi stranded, single core copper conductor FRLS ( Flame Retardant Low Smoke) cable 1.50 Sqmm suitable for fixing in concealed PVC conduit of size not less than 20 mm dia with modular metal flush boxes including modular white cover plate with frame of required module. Metal flush box should not less than 2 mm thick duly painted inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer of required module suitable for housing modular switches, socket, fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor FRLS cable 1.50 Sqmm used as earth wire to common earth and connected to common dolly and one run of 1.5 sqmm copper wire for inverter connection drawn in same conduit all as specified. |
| 3 | Same as item No 2 above but one 3/5 pin socket out let 5 amp on same board with other switches. |
| 4 | Same as item No 2 above but socket out let 5 amp on independent board. |
| 5 | Same as item No 2 above but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm size. |
| 6 | Same as item No 2 above but one light point controlled by two two way switches. |
| 7 | Same as item No 2 above but socket out let 3/6 pin 15 Amp with 2.5 Sqmm size copper conductor for power point on independent board. |
| 8 | Supply & Fixing switch modular single pole, one way 6 Amp, 01 module. |
| 9 | Supply & Fixing switch modular bell push 6 Amp, 01 module. |
| 10 | Supply & Fixing switch modular, two way 6 Amp, 01 module. |
| 11 | Supply & Fixing switch modular single pole, one way 16 Amp, 01 module. |
| 12 | Supply & Fixing modular socket 6 Amp 2/3 pin combined, 2 module. |
| 13 | Supply & Fixing modular socket 6/16 Amp 2/3 pin combined, 2 module. |
| 14 | S&F Modular electronic type step fan regulator, 120 W, 2 module. |
| 15 | M&L light/ fan point controlled by one switch with PVC insulated, unsheathed , multi stranded , single core copper conductor cable 1.50 Sqmm FRLS ( Flame Retardant Low Smoke) suitable for fixing in concealed conduit 20 mm dia with sunken pressed steel terminal boxes 2 mm thick of required size , duly painted inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer including 3 mm thick plastic laminated sheet cover housing switches ,socket, fan regulator etc. PVC insulated, unsheathed, multi stranded, single core copper conductor cable 1.50 Sqmm used as common earth wire and connected to common earth dolly & drawn in same conduit all as specified. |
| 16 | Same as item No 15 above but one 3/5 pin socket out let 5 amp on same board with other switches. |
| 17 | Same as item No 15 above but socket 5 amp on independent board. |
| 18 | Same as item No 15 above but One bell/ buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 Sqmm size |
| 19 | Same as item No 15 above but one light point controlled by two two way switches. |
| 20 | Same as item No 15 above but socket out let 3/6 pin 15 Amp with 2.5 Sqmm size copper conductor for power point on indipendent board. |
| 21 | Supply & Fixing switch piano flush type single pole one way 5 Amp. |
| 22 | Supply & Fixing bell push flush type 5 Amp switch. |
| 23 | Supply & Fixing switch piano flush type two way 5 Amp. |
| 24 | Supply & Fixing socket out 3/5 pin 5 Amp flush type. |
| 25 | Aupply & Fixing switch socket combination 2 in 1, 5/6A universal type |
| 26 | Supply & Fixing socket outlet 3/6 pin 5/15 Amp flush type. |
| 27 | Supply & Fixing switch socket combination 3/6 pin 5/15 Amp universal type. |
| 28 | Supply & Fixing electronic stepped type fan regulator. |
| 29 | Supply & Fixing call bell ding dong type 230 Volts AC supply. |
| 30 | Supply & Fixing ceiling rose surface backlite 65X20 mm two to three terminals complete. |
| 31 | Supply & Fixing lamp holder PVC / Ploycarbonate type. |
| 32 | Taking down carefully copper/aluminium power/sub main wiring of any size / type all as specified and directed. |
| 33 | M & L for power/sub main wiring with four runs of single core 6 sqmm size and one run of single core 6.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note : Four runs of 6 Sqmm single core copper conductor and one runs of 6.0 Sqmm copper conductor shall be measured as one unit length. |
| 34 | M & L for power/sub main wiring with two runs of single core 4 sqmm size and one run of single core 4.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note : Two runs of 4 Sqmm single core copper conductor and one runs of 4.0 Sqmm copper conductor shall be measured as one unit length. |
| 35 | M & L for power/sub main wiring with two runs of single core 6 sqmm size and one run of single core 6.0 sqmm (green colour as earth continuty conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through and including rigid PVC concealed conduit complete all as specified and directed. Note: Two runs of 6 Sqmm single core copper conductor and one runs of 6.0 Sqmm copper conductor shall be measured as one unit length. |
| 36 | Supply & fixing earth plug enclosure (plug and socket ) with MCB, SP 20 Amps modular type complete all as specified and directed. |
| 37 | Taking down existing light fitting of any type,make & capacity . |
| 38 | Supply and fixing energy saving LED lights fitting 1x 20W, 220V, AC, natural white / warm whitedecorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including its all acessories complete all as specified and directed . |
| 39 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 40 | Supply and fixing recess/surface mounting LED luminaire of size 600 mmx 600 mm white 35/36 watt, 230 volts with driver connector block etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. |
| 41 | Supply & Fixing recess/surface mounting sleek round / Square LED downlight luminaire white 15 Watt , 230 Volts, complete with driver, connector block ,etc, complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size. |
| 42 | Supply & Fixing integral LED bulkhead luminaire, 10 W, 230 Volts, IP 65 protection decorative surface mounted , complete with all accessories pre wired and including connecting up with twin core twisted flexible copper conductor of suitable size. |
| 43 | Supply & Fixing in replacement Bldg security LED light fittings with pressure dia cast aluminium of 35 watts and including and connceting up ceiling rose and fittings with 3 core, PVC insulated multistranded copper conductor cable of 1.5 Sqmm complete all as specified and directed. |
| 44 | Supply & Fixing in replacement LED lamp 12 Watt. |
| 45 | Supply & Fixing in replacement LED lamp 9 Watt . |
| 46 | Supply and fixing rechargeable LED bulb Cool Day light 9/10 watts having Luminous Efficacy range lies between ( ≥100 and <105 ) lm/W,CRI 80 as per BEE guidelines Long Life 25000 hours , colour temp 6500 K , frosted glass min back up time 4 Hrs after charge, In-built surge protection of 3 KVA 220V,AC complete all as specified and directed. |
| 47 | Taking down old U/S MCCB/MCB DB of any type, make complete all as specified and directed. |
| 48 | Supply & Fixing sheet metal enclouser MCCB DB IP 43 double door bus bar neutral link earth bar and din rail TPN 4 way complete all as specified and directed. |
| 49 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 12 way complete all as specified and directed. |
| 50 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail SPN 8 way complete all as specified and directed. |
| 51 | Supply & Fixing sheet metal enclouser MCB DB double door bus bar neutral link,earth bar and din rail TPN 4 way complete all as specified and directed. |
| 52 | Taking down old U/S MCCB / MCB of any type,make complete all as specified and directed. |
| 53 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,100 Amps with breaking capacity 16 KA fixed type all as specified and directed. |
| 54 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz,125 Amps with breaking capacity 16 KA fixed type all as specified and directed. |
| 55 | Supply & Fixing MCB TPN 16 to 32 Amps 415 volts, 10KA \\"C\\" curve complete all as specified and directed. |
| 56 | Supply & Fixing MCB TPN 40 to 63 Amps 415 volts, 10KA \\"C\\" curve complete all as specified and directed. |
| 57 | Supply & Fixing MCB SPN 32 Amps 240 volts, 10 KA, \\"C\\" curve complete all as specified and directed. |
| 58 | Supply & Fixing MCB SPN 40 to 63 Amps 240 volts, 10 KA, \\"C\\" curve complete all as specified and directed. |
| 59 | Supply & Fixing MCB SP 5 to 32 Amps 240 volts, 10 KA, \\"C\\" curve complete all as specified and directed. |
| 60 | Taking down ceiling fan of any sweep from its position opening the fan for inspection of worn out/ unserviceable parts. Repairing with replacement of unserviceable parts if required cleaning of blade and body properly oiling, greasing of bearing/ bush all as specified and fixing the fan in position all as specified and directed. Note :- Parts to be replaced will be measured and paid separetly. |
| 61 | M & L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning of dust etc. |
| 62 | Transporting of unserviceable ceiling fans of 1200 mm sweep to work shop and carrying out rewinding to the starter by using superior quality enameled copper conductor of matching size in weight gauge, application best quality of supper enameled insulation material tapping varnishing drying and re-fitment with testing complete all as specified and directed. |
| 63 | Same as item No 62 above but for ceiling fan of 1400 mm sweep 230 volt AC 50 Hz. |
| 64 | Same as item No 62 above but for heavy duty exhaust fan 300mm sweep 230 volt AC 50 Hz. |
| 65 | Same as item No 62 above but for wall mounting fan 400mm sweep 230 volt AC 50 Hz. |
| 66 | Supply & fix in replacment ceiling fans having copper winding motor, complete with remote and other accessories 230 V,50 Hz AC ,1200 mm sweep. With service value 6 .00 BEE 5 star rated with BLDC motor (Brushless direct current motor) complete all as specified and directed. |
| 67 | Supply and fix ceiling fans, complete with three blades, down rod, accessories 230V, 1200mm sweep and Squirrel cage induction motor complete all as specified and directed. |
| 68 | Supply and fixing wall mounting fan metal body 400mm sweep 230 volt AC 50 Hz. |
| 69 | Supply & fix in replacement exhaust fans heavy duty complete PVC body and copper winding fan motor,1200 rpm ,AC single phase 230/ 240 V, 50 Hz AC, of size 300 mm sweep with louver including testing and commissioning complete all as specified and as directed. |
| 70 | Supply and fixing in replacement capacitor 2.5/3.15 mfd. |
| 71 | Supply and fixing in replacement ball bearing of size 6201 / 6202 / 6203 NBC suiatable for ceiling fan / exhaust fan. |
| 72 | Supply and fixing in replacement rubber bush ( reel type) suiatable for 1200mm/1400mm sweep ceiling fan. |
| 73 | Taking down water heater (Geyser) storage type of any make of 25/35/50 litres capacity from any position, after disconnection of all electrical, water supply inlet and outlet connection and transportation to workshop for repair, further dismantling, segregation of serviceable and unserviceable parts, replacement unserviable parts and re-assembly the water heater and installation the same to their original position or as directed after all testing of water heater complete all as specifed and as directed.Note : (a) Cost of transportation shall be deemed to be included in this item.(b) Replacement of defective parts shall be measured & paid separately under respective item of this BOQ.(c) Descaling/ Welding/breezing/Painting of water heater if required shall be measured & paid separately under respective item of this BOQ. |
| 74 | M&L for welding/breezing of water heater tank of any size, model at appropriate/bursting area of copper/mild steel inner tank and make 100% leak proof complete all as specifed and directed. |
| 75 | M&L for descaling of water heater storage tank of any type, size and make by appling descaling solution. |
| 76 | M & L for appling one coat of synthetic enemal paint first grade of approve make and colour by spray machine after preparation of steel surfaces including writing MES No of 40mm size of letter for 50/35/25 Ltrs capacity of water heater complete all as specifed and directed. |
| 77 | Supply and fix inner tank made of stainless steel for water heater of 25/35 ltrs capacity of existing type, model complete all as specifed and directed. |
| 78 | Supply and fixing apparatus plate suitable for water heater 25 / 35 ltrs capacity of approved make and as per existing type and size including rubber gasket, clips, nuts, bolts, and washers etc complete all as specifed and as directed. |
| 79 | Supply and fixing in repair thermostat switch (ISI mark) suitable for 25 / 35 ltrs capacity water heater (geysers). |
| 80 | Supply and fixing in repair heating element (rounded / threaded rounded / trangular type base) of capacity 1500/2000 watt suitable for horizontal/ vertical type of geysers 25 / 35 ltr capacity (ISI mark). |
| 81 | Supply and fixing in repair neon indicating lamp, rectangular /round type as per existing model. |
| 82 | Supply and fixing in repair pressure release valve 15 mm bore (ISI marked) for geyser 25 / 35 ltrs capacity. |
| 83 | Supply and fixing in repair safety valve for water heater of capacity 25/35 ltrs. |
| 84 | Supply and fixing in repair apparatus plate rubber gasket suitable for six/seven/eight/nine hole assembly of suitable size of water heater of capacity 25/35 litres capacity. |
| 85 | Supply and fixing in repair split bottom cover (two pieces) suitable for water heater 25/35 litres capacity duly painted, all directed. |
| 86 | Supply and fixing 100 mm long and 12 mm dia anchor fastner nut and bolt with suitable washers complete all as specifed and directed. |
| 87 | M&L for insulating material (glass wool) suitable water heater insulation complete all as specifed and as directed. |
| 88 | Supply and fixing in repair hot and cold type PVC connection (ISI Mark) having 10 mm dia, 45 cm long with 02 Nos of Unions/ cup shaped pvc cover with washers complete all as specifed and directed. |
| 89 | Supply and fixing in repair 2.5 Sqmm 3 Core (Nominal Area) PVC Sheathed multi stranded unarmered copper conductor cable LT 1100 volt grade Conforming to IS 7098 complete all as specified and diriected. |
| 90 | Supply and fix electric water heater,storage type with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete and taking down the old unsv one,depositing in MES yard complete all as specified and directed. |
| 91 | Taking down window/Split type air conditioner for complete serviceing & cleaning with water and suitable cleaning agent properly, cleaning of all filter, checking of refrigerant gas pressure, checking of all spare parts serviceability, tightening carefully loose connection and re-fixing in same position or different location as directed and making the duct air tight by using foam and other necessary packing materials and testing complete all as specified and directed. |
| 92 | Taking out refrigerator/water cooler/deep fridge of any capacity from store yard / site to the workshop and dismentle the complete eqpt and carry out necessary mechinary work for complete serviceing & cleaning with water and suitable cleaning agent properly, cleaning of all filter, checking of refrigerant gas pressure, checking of all spare parts serviceability, tightening carefully loose connection and re-fixing in same position or deposted to store yard and testing complete all as specified and directed. |
| 93 | Taking down desert cooler of any capacity for complete serviceing & cleaning with water and suitable cleaning agent properly, cleaning of all filter, checking of all spare parts serviceability, tightening carefully loose connection and re-fixing in same position or different location as directed and testing complete all as specified and directed. |
| 94 | Supply and fixing in repair compressor for Refrigerator n. exe. 230 Ltr capacity including charging of gas R-134 and anti vibration rubber pad including testing and reinstallation at site or deposited to store yard complete all as specified and directed. |
| 95 | Supply and fixing in repair compressor for Refrigerator of capacity exc 240 Ltrs but n. exc 340 Ltr capacity including charging of gas R-134 and anti vibration rubber pad including testing and reinstallation at site or deposited to store yard complete all as specified and directed. |
| 96 | Same as item No 95 above but for water cooler of any type and capacity, recharging of compressor with gas R-134 complete all as specified and directed. |
| 97 | Supply and fixing in repair rotary compressor for air conditioner window/split type 1.5 Ton capacity including charging of Freon R-22 gas up to required level and replacement of anti vibration rubber pad and testing or reinstallation at site or deposited to store yard complete all as specified and directed. |
| 98 | Supply and fixing in repair rotary compressor for air conditioner window/split type 2.0 Ton capacity including charging of Freon R-22 gas up to required level and replacement of anti vibration rubber pad and testing or reinstallation at site or deposited to store yard complete all as specified and directed. |
| 99 | M&L for repair to body of any type of refrigerator / water cooler including cutting of worn out portion & make good the same, denting, craging of existing paint with existing colour approved paint including testing complete all as directed. |
| 100 | M&L for preparation of existing external surface of Refrigerator / water cooler / deep freezer and applying two coats of synthetic enamel paint over a coat of red oxide primer of approved colour with spray machine painting and writing MES/SM /Sl No complete all as specified and directed. |
| 101 | Supply and fixing fan motor for window/Split type air conditioner 1.5/2.0 ton capacity complete all as specified and directed. |
| 102 | M&L for taking out and replacement of condenser for refrigerator of any capacity of existing size & dia, including testing complete all as specified and directed. |
| 103 | M&L for taking out fan motor from water cooler of capacity 40/40 ltrs or 40/80 ltrs and replace with new fan motor complete set as per existing size, model including testing complete all as specified and directed. |
| 104 | Supply and fixing in repair and replacement of submersible water pump for desert cooler as per sample approved complete all as specified and directed. |
| 105 | Supply and fixing in repair and replacement of refrigerator starting Relay/ OLP as per existing size and model complete all as specified and as directed. Make: Danfoss or equivalent as approved complete all as specified and directed. |
| 106 | S&F in repair and replacement of Printed Circuit Board (PCB) with remote control and all other accessories suitable for window type air conditioner complete all as specified and directed. |
| 107 | S&F in repair and replacement of Printed Circuit Board (PCB) with remote control and all other accessories suitable for Split type air conditioner complete all as specified and as directed. |
| 108 | Supply and fixing in repair and replacement of air conditioner drain pipe window/split type of any capacity as per existing size and model complete all as specified and as directed. |
| 109 | Supply and Charging of fresh Gas R-134 including testing complete all as specified and directed. |
| 110 | Supply, fixing and clamping jointing of copper tubing of existing size for suction line and for liquid discharge line including making hole in wall for passing through and making good the disturbed surface omplete all as specified and directed. |
| 111 | S&F 3 pin 15 Amps plug top complete all as specified and directed. |
| 112 | S&F 3 pin 5 Amps plug top complete all as specified and directed. |
| 113 | Material & Skilled labours for attending of day to day complaints of E/M nature (Elect supply) for repair/ replacement of minor accessories like flexible wire/insulation tape/screws etc which are deemed to be included in this job and will not be paid separately including testing complete all as directed. Note :- (a) Contractor should have to receive complaints trough day to day basic from MES complaint cell.(b) Major Spare parts will be measured and paid separatly under respective items of this BoQ.(c) Reqd tools, laddar etc will be provided by the contractor.(d) Sefety precaution will be responsibility of the contractor. |
| 114 | M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth wire 4 mm dia as earthing leads by means of bolts, nuts, check nuts and washers properly jointed as shown on drawings and including excavation, earth work. GI pipe light grade 15 mm bore for protection of GI earth wire from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed. |
| 115 | Taking down the existing defective LT UG cable from trenches / pipes / pole for fault finding / replacement, all as specified and directed of any size between 10 Sqmm to 50 Sqmm 3.5 core/4 Core. Note: Excavation and earth work will be measured and paid seperately under relevant item. |
| 116 | Taking down the existing defective LT UG cable from trenches / pipes / pole for fault finding / replacement, all as specified and directed of any size between 70 Sqmm to 95 Sqmm 3.5 core/4 Core. Note: Excavation and earth work will be measured and paid seperately under relevant item. |
| 117 | Supply, laying , jointing and testing XLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 10 Sqmm 4 core. |
| 118 | Same as item No 117 above but size 16 Sqmm 4 core. |
| 119 | Same as item No 117 above but size 25 Sqmm 4 core. |
| 120 | Same as item No 117 above but size 50 Sqmm 3.5 core. |
| 121 | Same as item No 117 above but size 70 Sqmm 3.5 core. |
| 122 | Same as item No 117 above but size 95 Sqmm 3.5 core. |
| 123 | Excavation in trenches n.exc. 1.5 m wide and n.exc.1.5 m deep in any type of soil and forming bottom surfaces for laying of cable complete all as specified and directed. |
| 124 | Supply & laying sand cushioning for cable protection in trenches 8 cm before laying cable and 15 cm thick over the cable complete all as specified and ditected. Note: Punned down thickness shall be measured and paid. |
| 125 | Supply & laying brick for protection of cable sub class 'B' laid dry flat across the cable with width equal to the length of whole bricks complete all as specified and ditected. |
| 126 | Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed. |
| 127 | Removal of surplus soil to a distance n. exc. 50 m and deposited where diredted at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed. |
| 128 | Boring, holes for inserting of 50/80 mm bore GI pipe under the road/hard standing or any other location upto 1200 mm deeep complete all as specified and ditected. |
| 129 | M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 130 | M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 131 | M & L GI pipe 80 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 132 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 200 Amps with breaking capacity 36 KA adjustable, theremal magnetic release type all as specified and directed. |
| 133 | S & F in replacement of MCCB 4 pole 415 Volt, 50 Hz, 63 Amps with breaking capacity 16 KA fixed, theremal magnetic release type all as specified and directed. |
| 134 | S & F Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm. |
| 135 | S & F Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3 ½ core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm. |
| 136 | S & F Cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy Based) and accessories suitable for 3 ½ core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm. |
| 137 | M&L for preparation of existing old painted surface of any description such as Panels any height and painted complete with one coats of primer (superior quality) and in blue color all around the panels. |
| 138 | Taking out cable loop after dismantling cable ends from panels, cutting/removing heated cable ends with burnt lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable neatly around loop for cable size 70 to 185 Sqmm. |
| 139 | M & L for preparation of existing old painted surface of any description such as LT/HT steel tubular electric pole/struts of any height and painted complete including cross arms bracing clamps etc with one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5 M height form the ground level/top of PCC copping including writing MES, LT/HT feeder No. and Pole No. (in capital letters) stencil cut decorative manner on pole using fluorescent paint as directed. |
| 140 | Supply and fixing in repair for three phase Amp meter digital type size 96 mm x 96mm square flush type complete all as specified and directed. |
| 141 | Supply and fixing in repair Indication lamp (RYB) LED type 240 volts AC 50 Hz complete all as specifeid and directed. |
| 142 | Supply and fixing in repair for three phase Voltmeter digital type of range 0-500V complete all as specifed and directed. |
| 143 | Supply and fixing in repair Voltmeter selector switch for (0-500 volts) voltmeter as per sample / existing model complete all as specified and directed. |
| 144 | Supply and fixing in repair Ammeter selector switch for (0-100 Amps) Ammeter as per sample / existing model complete all as specified and directed. |
| 145 | Supply and fixing in repair current transformer (CT) 240 volts 50 Hz of ratio 50/5A,100/5A, 200/5A, 300/5A as per existing at site and complete all as specified directed by EIC. |
| 146 | Supply and fix 11 KV , Triple pole, switch air break, gang operated ,mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps complete all as specified and directed. |
| 147 | Supply, fixing and testing 11 KV HT ceramic bushing of transformer 11 KV/433 volt outdoor of 63 KVA to 200 KVA complete all as specified and directed including taking out old bushing. |
| 148 | Supply fixing and testing ceramic bushing LT side of transformer 11 KV/433 volt outdoor of 63 KVA to 200 KVA complete all as specified and directed including taking out old bushing. |
| 149 | Painting of transformer after cleaning the body surface of transformer by rubbing with emery paper to remove oil strains, dust etc and applying two coat of heat resistance paint by spray paint incl writing SM/MES no and capacity of outdoor transformer of 63 KVA to 200 KVA complete all as specified and directed. |
| 150 | Dehydration / filteration of transformer oil by means of centrifugal filteration plant to achieved the specified dielectric strength upto 60 KV at 2.5 mm gap in existing possesion of transformer of any capacity and transformer oil for toping up at various sub station complete. Note: Oil for topping shall be measured & paid for seperately under respective item of this schedule of work after dehydration/ filtteration of existing oil. |
| 151 | Supply only transformer oil of approved quality as per IS No : 335-1993 low viscosity type having dielectric strength of 65 KV in 2.5 mm gap for toping up complete all as specified and directed. |
| 152 | M & L for cutting of grass at sub stations, EM installations and surrounding areas etc complete or when and where directed and removing the same from the site to a distance not exceding 50 mtr complete and spreading of bleaching powder at the rate of 1kg/10 Sqm for stop the abnormal growth of grass all as specified and directed. |
| 153 | Cutting & trimming of tree branches along LT over head lines after taking all precautions while working on lines such as taking shut down , safety equipments etc . and clearing of area and removing the same from site to a distance not exceeding 50 mtr complete all as specified and directed. NOTE: Contractor shall be responsible for cutting of girth of tree branches upto 50 mm dia with the girth of tree branches above 50 mm dia & rate shall be deemed to be inclsive in unit quated rate . |
| 154 | M & L for PVC insulated, stranded aluminium conductor served with inner sheathing PVC tape and over all PVC sheathed of 10 Sqmm 2 core,complete all as specified and directed . |
| 155 | Supply and fixing in repair for PVC Sleeves heat shrink type of 16 Sqmm to 70 Sqmm size single core for provides underground cable/bus bar insulation as per colour required at site complete all as specified and directed. |
| 156 | Supply and fixing in repair PVC Sleeves heat shrink type of 95 Sqmm to 120 Sqmm size single core for provides underground cable/bus bar insulation as per colour required at site complete all as specified and as directed. |
| 157 | M&L earthing complete with galvanised steel earth plate 600X600X6.3 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside Welding / brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed. |
| 158 | Disconnecting and taking down existing any type of street/security light fitting of any make or any capacity for repair or replacement of burnt/worn out accessories (LED lamp/bulb, LED driver, SPD etc) through ladder/motorised/manual system from GI bracket on pole of any size and refixing the same after cleaning, general overhauling, repairing and making serviceable and refixed the same in same location or any other location and testing complete all as directed. Note :- (a) Contractor should have to receive complaints trough day to day basic from MES Power House.(b) Spare parts will be measured and paid separatly under respective items of this BoQ. |
| 159 | Supply only Surge Protection Device(SPD) 5 KV 240 volts water seal type suitable for LED industrial light and outdoor street/security light fitting upto 75 watt complete all as specified and directed. |
| 160 | Supply only Surge Protection Device (SPD) 10 KV 240 volts water seal type suitable for LED industrial light and outdoor street/security light fitting above 75 watt and upto 150 watt complete all as specified and directed. |
| 161 | Supply only LED outdoor drivers of capacity 25/30 watt 240 volts suitable for outdoor street/security light including all necessary fixing accessories complete as per existing make and model of light fitting complete all as specified and directed. |
| 162 | Supply only LED outdoor drivers of capacity 40/45 watt 240 volts suitable for outdoor street/security light including all necessary fixing accessories as per existing make and model of light fitting complete all as specified and directed. |
| 163 | Supply only LED outdoor drivers of capacity 75/80 watt 240 volts suitable for outdoor street/security light including all necessary fixing accessories as per existing make and model of light fitting complete all as specified and directed. |
| 164 | Taking down old unserviceable convetional street light fitting /post top lantern/flood light etc of any type/model including associated accessories from 8.5/9 mtr pole/Top of the building/High mast or other similar situation for replacement complete all as specified and directed. |
| 165 | Supply & Fixing 60 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 5700K. complete all as specified and directed. |
| 166 | Supply & Fixing 70 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 5700K complete all as specified and directed. |
| 167 | Supply & Fixing 90 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 6500K complete all as specified and directed. |
| 168 | Supply & Fixing LED Flood Light , 100 W Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 protectionand impact resistance of IK07 with 10KV Built-in-Surge Protection device, ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 5700K ,flood light, suitable for high mast application, highlighting architectural facade and general purpose lighting complete all as specified and directed. |
| 169 | Supply & Fixing LED Flood Light , 120 W Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 protectionand impact resistance of IK07 with 10KV Built-in-Surge Protection device, ,lumens should be ≥ 120 lm/w ,OEM driver,PF 0.9,CCT 5700K ,flood light, suitable for high mast application, highlighting architectural facade and general purpose lighting complete all as specified and directed. |
| 170 | Supply and fixing LED doom post top light fitting luminaires 40 watts IP 65 type made in die-cast aluminium housing with decorative opel polycarbonate diffuser complete with control gear box and all accessories duly prewired and connecting to junction box and testing complete all as specified and directed. |
| 171 | Supply and fix in replacement PVC Jnction Box on pole / wall of Size 20 cm x20 cm x10 cm with hinged door inculding locked arrangment with MCB SP 6 Amps 1 No including necessary clamping. Nuts, bolt etc complete all as directed. |
| 172 | Supply and fix in replacement PVC sheathed multi stranded unarmered copper conductor cable of size 1.5 Sqmm 3 core from pole junction box to light fitting with suitable size copper lugs and connector all complete as specified and directed. |
| 173 | Supply and fix in replacement PVC insulated and sheathed multi stranded unarmered aluminium conductor cable of size 4 Sqmm single core including all fixing arrangement complete as specified and directed. |
| 174 | Supply and fix in replacement PVC insulated and sheathed multi stranded unarmed aluminium conductor cable of size 4 Sqmm two core including all fixing arrangement complete as specified and directed. |
| 175 | S&F 40 mm bore GI pipe medium grade bracket fixed on pole for street light on LT poles/walls, suitable for street light fittings, not less than 1.20m long and bent to shape as required including necessary clamps, nut and bolts complete all as specified and directed. |
| 176 | S&F 25 mm bore GI pipe medium grade brackets fixed on pole for street light on LT poles/walls, suitable for street light fittings, not less than 1.20m long and bent to shape as required including necessary clamps , nut and bolts complete all as specified and directed. |
| 177 | Material and labour for repair/servicing of DG Set of capacity 62.5 KVA by replacement of un-serviceable spares i.e. diesel filter, lubricating oil filter, radiator hose pipe, fan belt, fuel returning/ pressure pipe, fuel and oil pressure gauge, battery terminal/ lugs nut bolts, cleaning/ repairing of fuel tank, replacement of engine oil as required at site including testing of DG sets on load to check the smooth functioning, complete all as specified and as directed Note :- replacement of items shall be measured and paid separately under the respective items of this BoQ. |
| 178 | Same as item No 177 above but for DG set of capacity 40 KVA. |
| 179 | Same as item No 177 above but for DG set of capacity 30 KVA. |
| 180 | Supply and fixing of fuel filter (primary & secondry) of existing model/ make suitable for DG sets of capacity 62.5 KVA complete all as specified and directed. |
| 181 | Same as item No 180 above but for DG set of capacity 40 KVA. |
| 182 | Same as item No 180 above but for DG set of capacity 30 KVA. |
| 183 | Supply and fixing of oil filter of existing model/ make suitable for DG sets of capacity 62.5 KVA complete all as specified and as directed. |
| 184 | Same as item No 183 above but for DG set of capacity 40 KVA. |
| 185 | Same as item No 183 above but for DG set of capacity 30 KVA. |
| 186 | Supply and fixing of air filter of existing model/ make suitable for DG sets of capacity 62.5 KVA complete all as specified and directed. |
| 187 | Same as item No 186 above but for DG set of capacity 40 KVA. |
| 188 | Same as item No 186 above but for DG set of capacity 30 KVA. |
| 189 | Material and labour for dismantling and removing of radiator assembly of the following DG sets of capacity 62.5 KVA from the base complete straightening of defective fins of radiator including cleaning of radiator with descaling solution & replacement of rubber hose pipe and clamps, fan bearing, impellers, bushes, gasket etc complete all as specified and directed. |
| 190 | Same as item No 189 above but for DG set of capacity 40 KVA. |
| 191 | Same as item No 189 above but for DG set of capacity 30 KVA. |
| 192 | Material and labour for calibration of fuel injector assembly of DG sets of capacity 62.5 KVA at authorised workshop including replacement of cup, barrel and plunger injector washer, nuts bolts etc complete all as specified and directed. |
| 193 | Same as item No 192 above but for DG set of capacity 40 KVA. |
| 194 | Same as item No 192 above but for DG set of capacity 30 KVA. |
| 195 | Material and labour for taking out FIP aassembly of DG sets of capacity 62.5 KVA, transport to civil work shop / authorised service centre, repairing, servicing, calibration of fuel pump assembly including replacement of unserviceable parts such as delivery valves, plunger , O rings, spring etc and refixing on original position complete all as specified and directed. |
| 196 | Same as item No 195 above but for DG set of capacity 40 KVA. |
| 197 | Same as item No 195 above but for DG set of capacity 30 KVA. |
| 198 | Supply and Fixing in replacement battery charger heavy duty 180 AH, 9 to 24 volts adjustable battery lead, with ampere meter complete all as specified and directed. |
| 199 | Supply and top up of engine oil 15W30 complete all as specified and directed. |
| 200 | Supply and top up of coolent for DG Set radiator complete all as specified and directed. |
| 201 | Supply and fixing of automatic voltage regulator of existing model/make suitable for DG sets of capacity 30 KVA to 62.5 KVA complete all as specified and directed. |
| 202 | Supply and fixing fan belts of existing model/make suitable for DG sets of capacity 30 KVA to 62.5 KVA complete all as specified and directed. |
| 203 | Supply and fixing of self starter 12 volts suitable for DG sets of capacity 30 KVA to 62.5 KVA complete all as specified and directed. |
| 204 | Supply and fixing on laod change over switch conforming to IEC 947-3 EN-60947-3AC-23A front operated 4 pole 415V, 50HZ with sheet steel enclosures of capacity 160 Amps complete all as specified and directed. |
| 205 | Same as item No 204 above but of capacity 125 Amps. |
| 206 | Same as item No 204 above but of capacity 63 Amps. |
| 207 | Supplying and installing lead acid battery 12 V 110 AH sealed, maintenance free including all connections complete all as specified and directed. |
| 208 | Supplying and installing in replacement of lead acid battery 12 V 180 AH sealed, maintenance free including all connections complete all as specified and directed. |
| 209 | Supply and fixing in replacement of Battery Lead, PVC insulated multi stranded copper conductor with copper lugs & terminal of suitable size of length 1.5 Metre complete all as specified and directed. |
| 210 | Supply and fixing in replacement LED display & control unit displaying running time, oil pressure, temp sensors set points, remote and local start/stop capabilities suitable for DG sets of capacity 30 KVA to 62.5 KVA, complete all as specified and directed. |
| 211 | Material and labour for servicing, repairing, maintenance of alternator assembly by opening/removing from DG set of capacity 30 to 32.5 KVA, replacement of carbon bush holder with carbon bush, bearing, mopeds, defective rectifier, capacitor, armature winding and refixing the same in original position complete all as specified and directed. |
| 212 | Supply and fixing in replacement coupling of alternator & engine with necessary nut bolts, key set complete all as specified and directed. |
| 213 | Supply and fixing in replacement selector switch auto/ manual/ test 24 volts DC of existing make and size complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender