Tender For Repair Or Replacement Of Storage Type Water Heaters, Exhaust Fans And Allied Works At 509 Su, Af Station Laitkor Peak Under Ge (I) (Af)
Tender Value
15 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
8 days left
EMD
30000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
East Khasi Hills → Meghalaya
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Or Replacement Of Storage Type Water Heaters, Exhaust Fans And Allied Works At 509 Su, Af Station Laitkor Peak Under Ge (I) (Af)
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully old unsv point wiring complete incl fittings such as switches, conduit,wires,celling roses, light fittings etc and making good the disturbed surface complete all as specified and as directed. |
| 2 | M&L for Concealed type point wiring with 1.5 sqmm (nominal cress-sectional area) PVC insulated unsheathed single core multi stranded copper FRLS cable working voltage 1100 volts grade conorming to IS-694 with stranded copper conductor including PVC conduit of adequate size having a wall thickness ont less than 1.5 sqmm with all accessories (including cutting chases & making good the disturbed surface to its original specifiecation) including1.5 sqmm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for one light/fan point controlled by one way switch. |
| 3 | All as per items No- 02 here in before but point wiring with 2.5 sqmm multistranded conductor for 15 Amp point on independent board complete all as specified and directed by Engineer-in-charge. |
| 4 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with din rail, IP-20 protection suitable for fixing MCB\\"S/lsolators complete all as specified and directed. |
| 5 | S&F MCB, Single pole & neutral,6 to 32 amps, 240 volts, ‘C’ curve, 10KA all complete as specified and as directed |
| 6 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed |
| 7 | M&L in repair for earthing complete with Galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI wire of size 4 sqmm as earthing leads by means of bolt, nut, check nuts and washers galvanised iron or steel all as shown in elctrical plate No 3 of SSR Part I connected to earthing test point or as specified or indicated and testing on completion including excavation and earth work, PCC pit with RCC cover having suitable handle, 25 mm bore GI Medium grade watering pipe with funel and wire mesh, 15 mm dia GI Light grade Protection pipe complete. |
| 8 | M&L for taking down of U/s defective exhaust fan of sweep 150 - 400 mm with blade etc from wall by unscrewing the nut bolts ,opening the split pin and keeping insafe custody for refixing the same after repairs complete all as specified and as directed. |
| 9 | M&L for dismantling of exhaust fan of 250/300 mm sweep motor with louvers assembly for servicing after inspecting all dismantled parts for their serviceablity and cleaning , greasing and removing all deposited materials and replacing unserviceable parts and components with new ones and reassembling the same complete for smooth functioning by replacing the following spares:- Note : spare parts measured and paid separately. |
| 10 | M&L for rewinding of exhaust fan of 250/300 mm sweep motor with super enamelled copper winding wire of suitable gauge after cutting and removing burnt winding varnishing new winding drying up carefully all as specified and directed. |
| 11 | Supply only ball bearing suitable for exhaust fan of 250/300 mm sweep complete all as specfied and as directed.Make : TATA/SKF/NBC. |
| 12 | Supply only capacitor 2.5mfd of exhaust fan complete all as specified and as directed. |
| 13 | Supply only gun metal bush suitable for any type and any sweep of wall fan/exhaust fan complete all as specfied and as directed. |
| 14 | Supply only flexible wire twisted twin core of size 0.75 Sqmm, copper conductor complete all as specfied and as directed. |
| 15 | M&L for single coat painting to exhaust fan/ wall fan upto 400 mm sweep with 1st grade quality synthetic enamel paint by spraying, filling cavities with filler including necessary preparation of surface complete all as specfied and as directed. |
| 16 | M&L for cutting holes in circular shape in brick walls exceeding half brick but not exceeding one brick thick in cement mortar for fixing exhaust fan and making good disturbed surfaces in cement mortar (1:3) finished even and smooth and to match with existing as required complete all as specfied and as directed. |
| 17 | M & L in replacement for MS louvers with nuts, bolts and washers suitable to exhaust fan 300/450 mm sweep of any description make and model after taking down old existing unserviceable PVC MS louvers complete all as directed. |
| 18 | M&L in replacement for suitable frames of 300/450 mm sweep exhaust fan of any description make and model after taking down old existing unserviceable frames complete all as directed. |
| 19 | M & L in replacement for standard MS clamps with rubber shoe with bolts suitable to exhaust fan of any description, make and model after taking down old existing unserviceable clamps complete all as directed. |
| 20 | Supply fix in repair blade set for exhaust fan (set of three blades) 150-400 mm sweep as per existing make and size all as specified and directed. |
| 21 | Taking down the existing unsv storage type electric water heater (geyser)of any make/ capacity, installed at different location including dis-connecting, taking down opening all parts/accessories for inspection, cleaning, descaling, refixing serviceable parts, replacing unserviceable parts installed at old location and reconnection, testing complete all as directed by Engineer-in-Charge for the follwoing capacity :- 25/ 35 / 50 Ltr capacity |
| 22 | Supply only heating element round/ triangular/banana type for geysers including rubber washer for the 25-50 ltr capacity for any type of geyser as per existing. |
| 23 | Supply only PVC connection pipe with brass unions at both ends, 450mm long 15mm bore (for incoming cold water) all as specified and as directed. |
| 24 | Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and directed. |
| 25 | Supply only apparatus plate suitable for 35/25 ltrs capacity geyser.(Make : Bajaj/Recold/venus) |
| 26 | Supply only apparatus plate suitable for 50 ltrs capacity geyser |
| 27 | Supply only thermostat (ISI Marked) for 25 Liters capacity Geyser for any make of geyser |
| 28 | Supply only thermostat (ISI Marked) for 35 Liters capacity Geyser for any make of geyser |
| 29 | Supply only thermostat (ISI Marked) for 50 Liters capacity Geyser for any make of geyser |
| 30 | M & L for brazing/welding of copper/steel tanks 25/35 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 25/35 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type all as directed by Engineer -in - charge. |
| 31 | M & L for brazing/welding of copper/steel tanks 50 liters and refixing after testing the leakage complete incl replacement of insulating material (Glass wool) for 50 Liters capacity Geysers and replacement of rubber packaging ring heat resistsnt type all as directed by Engineer -in - charge. |
| 32 | S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge. |
| 33 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and directed. |
| 34 | S&F of Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type complete all as specified and directed by Engr-in-Charge. |
| 35 | Supply & Fixing Plug top, 3 pin, 15 amps, 230 volt, including electric connection after taking out old unserviceable one complete all as specified and directed. |
| 36 | S & F switch piano flush type 5/6 Amps, single pole, one way, 230 Volts complete all as specified and directed. |
| 37 | S & F ceiling rose, three terminal, PVC / poly carbonate isolated body, complete all as specified and directed. . |
| 38 | Supply & Fixing GI elbow 15 mm bore after taking out old unserviceable one complete all as specified and directed. |
| 39 | S&F stop valve, ISI marked, brass, 15mm bore after taking out defective/ unserviceable one complete all as specified and directed |
| 40 | S&F Bib taps 15 mm bore, cast copper alloy with fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed |
| 41 | M&L for concealed sub main wiring with 3 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable alongwith PVC conduit pipe shall be measured as one unit length. |
| 42 | M&L for sub main wiring with 3 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC casing capping complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable alongwith PVC Casing capping shall be measured as one unit length. |
| 43 | Single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amp |
| 44 | S& F Gun-metal, globe or gate valves 25 mm bore, with iron wheel head, screwed both ends for iron pipe and fixed all as specified and as directed. |
| 45 | M&L for sheet metal enclosure MCB distributon board, 2 way single door 230 volts all as specified and as directed. |
| 46 | M&L for GI water tubing medium grade 15 mm dia fixed on wall with all fittings and fixtures complete all as specified and directed. |
| 47 | S&F in replacement safety nut for pressure release valve (As per existing) complete all as specified. |
| 48 | S&F in replacement hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified. |
| 49 | S&F non return valve all as specified and directed |
| 50 | S&F in replacement rubber gas Kit suitable for 50/35/25 ltrs capacity geyser (as per sample) complete all as specified. |
| 51 | S & F in replacement red or green indicator light for geyser as per existing complete all as directed by Enge-in-charge |
| 52 | M&L for fixing of new/old geysers at new place with hole fastener and cement work including connection with existing pipes complete all as directed by Enge-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer