Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57488933

Tender For Replacement Of Meter With Boxes, Certain Electric Improvement Works Under Ge Nasik Road C

Issued by Statutory Bodies & Commissions/Committees · Nashik, Maharashtra
Tender Value
40 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
20 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Nashik → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Replacement Of Meter With Boxes, Certain Electric Improvement Works Under Ge Nasik Road C

BOQ

Name of Work:- REPLACEMENT OF METER WITH BOXES, CERTAIN ELECTRIC IMPROVEMENT WORKS UNDER GE NASIK ROAD C
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed.
2Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
3Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
4Supply, installation, testing, and commissioning of 6m high tri-color decorative pole/ bollard poles with bottom-mounted 60W LED fixtures- 02 Nos, complete in all respects. The bollard shall be fabricated from high-quality GI with durable PU paint finish, featuring a tapered profile (top dia 60 mm and bottom dia 150 mm), base diameter 140 mm, and mounted on a 250×250 mm base plate with suitable anchor fasteners. The pole shall be provided with a hinge-type access door for maintenance, along with an in-built control box neatly integrated and surface-mounted at the base, and installed on a pre-formed concrete foundation. The lighting fixture shall be a 02x60W LED with 3000K CCT and minimum efficacy of 110 lm/W, ensuring high energy efficiency and suitability for outdoor applications. The scope includes all civil works, erection, cabling, earthing, testing, and commissioning, ensuring reliable performance, safety, and aesthetically appealing installation, with complete handover in ready-to-use condition as per approved standards and specifications.Note : Rate for RCC foundation as per drawing, Excavation, returning filling, foundation anchor bolts and nuts included in this item rate.
5Disconnecting & taking out cable LT 1100V grade any size complete all as specified.
6Supply, laying in trenches or fixing or passing through pipe of 1100 Volts grade heavy duty LT UG cable, 2 core 6 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire/ strip and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed.
7All as per Ser item No 6 here in before but 2 Core 10 Sqmm
8All as per Ser item No 6 here in before but 2 Core 16 Sqmm
9All as per Ser item No 6 here in before but 4 Core 16 Sqmm
10All as per Ser item No 6 here in before but 4 Core 25 Sqmm
11All as per Ser item No 6 here in before but 3.5 Core 35 Sqmm
12M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mm including 90 degree bends with coupler and rubber ring laid in trenches for cable protection of 2 core 10 sqmm to 3.5 core 50 sqmm cable complete all as specified and directed.
13Dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc.
14Supply, fix and install 7 m height GI octagonal pole top 70 mm, bottom 130 mm, surface finished: hot dip galvanised, 3 mm thikness with base plate 200x200x12 mm and GI 64 micron, M19x600 EN 8 grade foundaction bolt and 1 m cantilever arm bracket sword type for light fittings complete including foundation drawing provided by OEM for foundation of pole including MCB 2.5 Amp SP, 230 Volts, with busbar.Note : Rate for RCC foundation as per drawing, Excavation, returning filling, foundation anchor bolts and nuts included in this item rate.
15Supply, install, test and commissioning in replacement of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- OUTER SHELL : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
16INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 630 Amps, 4 pole, 415 Volts, 50 Hz ICU 50 kA , with Microprocessor release between 70-100% - 01 No.(b) Outgoing : (i) MCCB 250 Amps, 3 pole, 415 Volts, 50 Hz ICU 36 kA thermally adjustable between 70-100% - 01 Nos. (ii) MCCB 160 Amps, 3 pole, 415 Volts, 50 Hz ICU 25 kA thermally adjustable between 70-100% - 01 Nos. (iii) MCCB 100 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA thermally adjustable between 70-100% - 03 Nos. (ii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 kA - 01 No.(c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.
17(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.(iv) Digital time switch with contactor 63 Amp.Location : Sub Station No. 10
18Demolition of PCC of any description above/below ground level exceeding 15cm complete all as specified and directed by Engr-in-Charge.
19M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etc all as specified and directed.
20M&L for PCC 1:2:4 type B2 using 40mm graded aggregate for coping including necessary form work and fair finishing of exposed surface of concrete all as specified and directed.
21Supply, install, testing and commissioning (including taking down old panel board) of outdoor type cubical panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following:- OUTER SHELL : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
22INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkA ble sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz ICU 35 kA thermally adjustable between 70-100% - 01 No.(b) Outgoing : (i) MCCB 100 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA thermally adjustable between 70-100% - 04 Nos. (i) MCCB 63 Amps, 3 pole, 415 Volts, 50 Hz ICU 10 kA thermally adjustable between 70-100% - 01 Nos. (ii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 kA - 01 No(c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96 mm x 96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.
23(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.(iv) Digital time switch with contactor 63 Amp.Location : Kargil Gate 4 pole structure
24Supply, install, test and commissioning (incl taking down old panel board) of indoor type LT panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- The shell shall be made out of 2 mm thick CRCA Sheet duly compartmentalized for each control gears, front openable single door system by keys. To accomodate incomer /outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkA ble sleeve and shall be mounted on suitable size 'F' class insulators. MS angle section 50x50x6mm frame,louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
25(a) Incoming : MCCB 400 Amps, 4 pole, 415 Volts, 50 Hz ICU 50 kA with microprocessor release - 01 No.(b) Outgoing : (i) MCCB 250 Amps, 3 pole, 415 Volts, 50 Hz ICU 36 kA with microprocessor release - 02 No.(ii) MCCB 200 Amps, 3 pole, 415 Volts, 50 Hz ICU 36 kA with microprocessor release - 02 No.(iii) MCCB 100 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA -02 Nos. (iv) Digital time switch with MNX 50 Contactor - 01 Set.(c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.Location : Sub Stn No 8
26S&F cross arms, Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts, washers, welding, bending, cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed.
27S&F in repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with screws on LT pole of size 20x15 mm
28Pole Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI wire 4.0 mm dia, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 15 mm, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion including taking down old earthing”.Note: These earthings shall be provided for poles; without provision of concrete earth pits.
29Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connecting to the GI strip 32x6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 m long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion including taking down old earthing”.
30M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine for LT underground cables suitable for 0.4 mPa working pressure complete all as specified and directed.
31Supply, install, test and commissioning (inclu taking down old panel board) of indoor type LT panel board suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shade having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- The shell shall be made out of 2 mm thick CRCA Sheet duly compartmentalized for each control gears, front openable single door system by keys. To accomodate incomer /outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkA ble sleeve and shall be mounted on suitable size 'F' class insulators. MS angle section 50x50x6mm frame,louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
32(a) Incoming : MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz ICU 25 kA with microprocessor release - 01 No.(b) Outgoing : (i) MCCB 200 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA - 02 Nos. (ii) MCCB 160 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA - 01 Nos. (ii) MCCB 100 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA - 03 Nos. (iii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 kA - 01 No.(iv) Digital time switch with MNX 50 Contactor - 01 Set.(c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.Location : Sub Stn No 6
33Supply, install, testing and commissioning (including taking down old panel board) outdoor type cubical panel board in lieu of bus bar panel box suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising the following:- OUTER SHELL : The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
34INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ICU 25 kA thermally adjustable between 70-100% - 01 No.(b) Outgoing : (i) MCCB 63 Amps, 3 pole, 415 Volts, 50 Hz ICU 10 kA thermally adjustable between 70-100% - 04 Nos. (ii) MCB 32 Amps, Triple pole & Neutral, 415Volts, 50 Hz ICU 10 kA - 01 No(c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.(iv) Digital time switch with contactor 63 Amp.
35Taking down after disconnecting of cable connections from old burnt/ unserviceable MCCB and S&F MCCB 160 Amps FP, 415 V with microprocessor release and breaking capacity 36 kA capacity, retrofit with fixing arrangement in the existing LT panel board complete all as specifiedand directed.
36All as per Ser item No 28 here in before but 250 Amps, 4 pole, 36 kA .
37All as per Ser item No 28 here in before but 400 Amps, 4 pole, 36 kA .
38All as per Ser item No 28 here in before but 630 Amps, 4 pole, 50 kA .
39M&L for locating fault in U/G HT cable by using fault detector machine including transportation and by carring out high pressure test all as directed.
40Supply, install, test and commissioning (incl taking down old panel boars) of outdoor type cubical panel suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 mircrons provided with suitable gasket to make it dust /vermin proof and general construction confirming to IS 8623793 comprising of the following :- OUTER SHELL: The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system locable/openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a ditachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accomodate inner shell described below giving minimum 75 mm space all round. Provision of threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54.
41INNER SHELL : Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accomodate incomer / outgoing MCCBs and TPN aluminium busbar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN busbar shall be insulated with colour coded heat shrinkA ble sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :- (a) Incoming : MCCB 160 Amps, 4 pole, 415 Volts, 50 Hz ICU 50 kA with microprocessor release - 01 No.(b) Outgoing : (i) MCCB 100 Amps, 3 pole, 415 Volts, 50 Hz ICU 25 kA with microprocessor release - 03 No.(ii) MCCB 63 Amps, 3 pole, 415 Volts, 50 Hz ICU 16 kA with microprocessor release - 01 No.(iii) Digital time switch with MNX 50 Contactor - 01 Set.(c) Instrumentation : The inner cubical shall carry the following :(i) Digital panel multifunction meter to measure current, Voltage, frequency & power factor having programmable CT ratio (CT ration should be equal to the rated current carrying capacity of incommer MCCB) & built in selector switch of size 96x96 mm accuracy class 1.0 suitable to work on auxiliary power supply of 240 Volts AC with backup protection by 2 Amp MCB.(ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incommer of the unit to show 3 phase availability at the outgoing of incommer with back up protection by 2 Amp MCB.(iii) Inspection LED invertor lamp12 Watt with movable non ferrous chromium plated arm fitted on topside of inner shell.Location : Shaurya JCO Mess
42NOTE: AMOUNT OF SCHEDULE OF CREDIT Rs. 1,67,340.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57488933
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 40 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Replacement Of Meter With Boxes, Certain Electric Improvement Works Under Ge Nasik Road C
Basic Detail
Tender No GE/NRC/8831/E8
Bidding Type Tender
Location
City Nashik
State Maharashtra
Key Dates
Publish Date 12 Sep 2026
Submission Date 03 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 40 Lakhs
Tender Fee 500
EMD 80000
Exemption Available
Document List
1ab061f1-40e0-48e9-98c3-ee94208eb241.html
8831PS.pdf
8831SOC.pdf
BOQ_884584.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 12, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

1ab061f1-40e0-48e9-98c3-ee94208eb241.html

pdf

8831PS.pdf

pdf

8831SOC.pdf

xls

BOQ_884584.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders