| Sl. No. | Item Description |
| 1 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning of Electromagnetic Flowmeter. O/p : 4-20 mA for Instantaneous Flow. RS-485 ModBus RTU for Instantneous Flow and Totalized Flow. Ingress Protection : IP-65 / 66, Refer to `Specifications` for details along with `Installation Guidelines`. Line Size : 100mm |
| 2 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning of Electromagnetic Flowmeter. O/p : 4-20 mA for Instantaneous Flow. RS-485 ModBus RTU for Instantneous Flow and Totalized Flow. Ingress Protection : IP-65 / 66, Refer to `Specifications` for details along with `Installation Guidelines` Line Size : 300mm |
| 3 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning of Electromagnetic Flowmeter. O/p : 4-20 mA for Instantaneous Flow. RS-485 ModBus RTU for Instantneous Flow and Totalized Flow. Ingress Protection : IP-68, Refer to `Specifications` for details along with `Installation Guidelines` Line Size : 150mm |
| 4 | Online Chlorine Sensor : Supply, Installation, Testing, Commissioning of Online Chlorine Sensor Refer to `Specifications` for details along with `Installation Guidelines` |
| 5 | Pressure Transmitter: Supply, Installation, testing, Commissioning of Pressure Transmitter to be installed at tail end.Measuring range – 0-2kg/cm2, Output – 4 to 20 mA. Refer Specifications for details. |
| 6 | Radar based Level Transmitter: Supply, Installation, testing, Commissioning of Radar Type Level Transmitter to measure Water level in UGT and / or OHR. Measuring range – 0 to 10 mtr , Refer Specifications for details. |
| 7 | Cloud based software: Cloud based software comprising of Middleware, Database and Front-end web interface through suitable Dashboards, Aggregation screens and GIS assisted drill down from macro to micro to be provided. Application data hosting and maintenance for one years included in scope. |
| 8 | Automation Panel for Pump and Motorized Butterfly Valve Control, as rerquired, along with Auto/Manual Selection Switch, Pusg Buttons for operation as required, operation through potential free/open collector digital outputs of RTU-cum-Gateway device or PLC plus Modem. The panel will contain RTU-cum-Gateway with necessary I/Os and edge controller function or PLC plus Modem with necessary I/Os , logic to operate PUMP and Motorized control valve in tandem with Cloud Schedu1ler or Level sensor-based functions.Panel will contain SMPS with rechargeable battery backup (min. 48 hrs.) along with facility to connect all field instruments with 24 VDC power supply. This Automation Panel shall be functionally integrated to the existing VFD Panel. Refer Specifications for details. |
| 9 | Field Instrumentation Panel: Comprising of RTU-Cum-Gateway or PLC plus Modem with RS485/Modbus aswell as discrete AI/DI to interface with remote location instruments like Field Flowmeter, Chlorine Analyzer and/or Pressure Transmitter etc. Power Supply based on solar panel of adequate capacity and rechargeable batteries with 24VDC output meant for smooth permanent operation of connected instruments to be provided. Shall be of IP64 Grade This panel will be wired for full functionality as desired. Refer Specifications for details. |
| 10 | RTU Integration: Functional Integration at RTU-cum-Gateway OR PLC plus Modem for Pump Control Panel |
| 11 | SIM Card: SIM Card for one year operation of all the instrument above as required. |
| 12 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning of Electromagnetic Flowmeter. O/p : 4-20 mA for Instantaneous Flow. RS-485 ModBus RTU for Instantneous Flow and Totalized Flow. Ingress Protection : IP-65 / 66, Refer to `Specifications` for details along with `Installation Guidelines`. Line Size : 200mm |
| 13 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning of Electromagnetic Flowmeter. O/p : 4-20 mA for Instantaneous Flow. RS-485 ModBus RTU for Instantneous Flow and Totalized Flow. Ingress Protection : IP-68, Refer to `Specifications` for details along with `Installation Guidelines`. Line Size : 100mm |
| 14 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning of Electromagnetic Flowmeter. O/p : 4-20 mA for Instantaneous Flow. RS-485 ModBus RTU for Instantneous Flow and Totalized Flow. Ingress Protection : IP-65 / 66, Refer to `Specifications` for details along with `Installation Guidelines`. Line Size : 150mm.. |
| 15 | Butterfly valve:- Supply, Installation, testing, Commissioning of Butterfly Valve with Electrical Actuator Pressure Rating – Ansi 150#. Feedback - 100% Open and 100% close. Refer to `Specifications` for details along with `Installation Guidelines` Line Size : 100mm **Unit Rate given, actual quantity to be ascertained while placing order |
| 16 | Butterfly valve:- Supply, Installation, testing, Commissioning of Butterfly Valve with Electrical Actuator Pressure Rating – Ansi 150#. Feedback - 100% Open and 100% close. Refer to `Specifications` for details along with `Installation Guidelines` Line Size : 200mm **Unit Rate given, actual quantity to be ascertained while placing order |
| 17 | Butterfly valve:- Supply, Installation, testing, Commissioning of Butterfly Valve with Electrical Actuator Pressure Rating – Ansi 150#. Feedback - 100% Open and 100% close. Refer to `Specifications` for details along with `Installation Guidelines` Line Size : 150mm **Unit Rate given, actual quantity to be ascertained while placing order |
| 18 | Entire Operation and Maintenance for 5 years (including dedicated Technician deployed at site for entire 5 years, all communication and hosting charges of the complete IOT based system). All hardware spares required for breakdown servicing to be paid as actual, Post 1 year warranty. |
| 19 | Butterfly valve:- Supply, Installation, testing, Commissioning of Butterfly Valve with Electrical Actuator Pressure Rating – Ansi 150#. Feedback - 100% Open and 100% close. Refer to `Specifications` for details along with `Installation Guidelines` Line Size : 300mm**Unit Rate given, actual quantity to be ascertained while placing order Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents