Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation, Biennial Rate Contract For Electrical Maintenance For Administrative And Priyadarshini Buildings,
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; Electrical System Or Installation, Biennial Rate Contract For Electrical Maintenance For Administrative And Priyadarshini Buildings, Cisf Barrack And Alli.. - Supplying & Laying Pvc Trunking (Pvc Casing-N-Capping) Of Size 20 Mm With Double Locking Arangement With Grooves, Trunking Of Size Not Below 12.5 Mm. In Height And Thickness Not Below 1.2 Mm. As Per Is 14927 Part-I Of 2001 And With Accessories Of Pvc/Resin Polyproelyne Not Below 1.8 Mm Thick, Duly Embossed The Name, Duly Sealed At Joints And Erected On Wall/Ceiling With Necessary Nettle Fold G.I Screws Fixed At Intervals Not More Than 500Mm Rawl Plugs Complete. , Supplying & Laying Pvc Trunking (Pvc Casing-N-Capping) Of Size 25 Mm With Double Locking Arangement With Grooves, Trunking Of Size Not Below 12.5 Mm.In Height And Thickness Not Below 1.2 Mm. As Per Is 14927 Part-I Of 2001 And With Accessories Of Pvc/Resin Polyproelyne Not Below 1.8 Mm Thick,Duly Embossed The Name, Duly Sealed At Joints And Erected On Wall/Ceiling With Necessary Nettle Fold G.I Screws Fixed At Intervals Not More Than 500Mm Rawl Plugs Complete. , Supplying & Laying Pvc Trunking (Pvc Casing-N-Capping) Of Size 32 Mm With Double Locking Arangement With Grooves, Trunking Of Size Not Below 12.5 Mm In Height And Thickness Not Below 1.2 Mm. As Per Is 14927 Part-I Of 2001 And With Accessories Of Pvc/Resin Polyproelyne Not Below 1.8 Mm Thick, Duly Embossed The Name, Duly Sealed At Joints And Erected On Wall/Ceiling With Necessary Nettle Fold G.I Screws Fixed At Intervals Not More Than 500Mm Rawl Plugs Complete. , Supplying & Laying Pvc Trunking (Pvc Casing-N-Capping) Of Size 40 Mm With Double Locking Arangement With Grooves, Trunking Of Size Not Below 12.5 Mm. In Height And Thickness Not Below 1.2 Mm. As Per Is 14927 Part-I Of 2001 And With Accessories Of Pvc/Resin Polyproelyne Not Below 1.8 Mm Thick,Duly Embossed The Name, Duly Sealed At Joints And Erected On Wall/Ceiling With Necessary Nettle Fold G.I Screws Fixed At Intervals Not More Than 500Mm Rawl Plugs Complete. , Scrapping Existing Paint Of Feeder Pillar/Switch Gears(Only Outside) And Frame Of Panel Board Completely Without Damaging And Painting The Same With Single Coat Of Red Oxide & Two Coats Of Approved Quality Enamel Paint In An Approved Manner. (The Square Metre Area Of Angle Iron Frame On Which The Switch- Gears Are Erected Shall Be Considered For Measurement Purpose) Red Oxide & Enamel Paint Is In Partys Scope (Rate Is In Sq.M) , Supplying And Fixing Condensor 2 / 1.85/2.25 Micro Farad For Ceilling Fan. , Supply & Replacement Of Wooden /Other Approved Material Board 4X4 , Supply & Replacement Of Wooden / Other Approved Board Of 4 To 7 , Supply & Replacement Of Wooden / Other Approved Boardboard 8 To 10 , Supply & Replacement Of Wooden / Other Approved Board Board 10 X 12 , Supplying And Erecting Plan Pendent Type Backellite L Holder Complete Erect At Position With Necessary Length Of Twin Flexible Wire( Upto 1 Mtr.) , Supply & Fixing Of Ding-Dong Bell , Supplying And Erecting Gls L 230V,60 / 100 W. , Making Trench In Hard Murum / Tar Road Of Suitable Width Of 0.9 M Deep For Laying Provided L.T. Cable. Half Round Hume Pipe Of 150 Mm Placed Length Wise On Top Of The Cable All Over The Run And Back Filling Theexcavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cms. Crown On The Top. (As Per Is 1255) (Rate Per Meter) , Laying Of Pvc Cable Alu/Cu Armoured/Unarmoured All Core 1.5 Sq Mm-10 Sq Mm On Wall/Provided Trench/On Ground/On Pole With Necessary Hardware. , Laying Of Cable Alu/Cu Armoured/Unarmoured All Core 16 Sq Mm-35 Sq Mm On Wall/Provided Trench/On Ground/On Pole With Necessary Hardware , Laying Of Cable Alu/Cu Armoured/Unarmoured All Core 50 Sq Mm- 120 Sq Mm On Wall/Provided Trench/On Ground/On Pole With Necessary Hardware , Laying Of Cable Alu/Cu Armoured/Unarmoured All Core 150 Sq Mm -400 Sq Mm On Wall/Provided Trench/On Ground/On Pole With Necessary Hardware , Dismantling The Existing Above Gound Cable Of All Types & Sizes , Dismantling The Existing Underground Cable Without Damaging It With Glands, Cables End Box Including Refilling The Trench Up To Ground Leveel And Making Coils Complete. , Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For L.T. Pvcpvcarmoured Cable 1.1 Kv Grade Complete With Ferrules & Bushing & Accessories And Suitable Cl S Duly Erected And Connected To The Supply For All Cores Cable 2.5 Sq.Mm To 16 Sq.Mm Cableconnected To The Supply For All Cores Cable 2.5 Sq.Mm To 16 Sq.Mm Cable Connected To The Supply For All Cores Cable 2.5 Sq.Mm To 16 Sq.Mm Cable , Providing & Erecting Epoxy Straight Through Joint For L.T. Pvc Armoured Cable 1.1 Kv Grade Complete With Ferrules & Bushing And Accessories And Suitable Cl S Duly Erected And Connected To The Supply For All Cores Cable 25 Sq.Mm To 50 Sq.Mm Cable , Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For L.T. Pvc Armoured Cable 1.1 Kv Grade Complete With Ferrules & Bushing And Accessories And Suitable Cl S Duly Erected And Connected To The Supply For All Cores Cable 70 Sq.Mm To 185 Sq.Mm Cable , Providing & Erecting Epoxy Straight Through Joint Outdoor / Indoor For L.T.Pvc Armoured Cable 1.1 Kv Grade Complete With Ferrules & Bushing And Accessories And Suitable Cl S Duly Erected And Connected To The Supply For All Cores Cable 240 / 300/400 Sq.Mm Cable , Supplying And Erecting Heavy Duty Siemens Type Brass Cable Glands For 3 To 4 Core 16Sq. Mm. To 3 To 4 Core 25 Sq. Mm./31/ 2X 35 Sq. Mm. Pvc Armoured Cable With Brass Washers Rubber Rings Complete Erected With Cable Ends & Leads Connected. , Supplying And Erecting Heavy Duty Siemens Type Brass Cable Glands For 3 To 4 Core 50 Sq. Mm. To 3 To 4 Core 70 Sq. Mm. Pvc Armoured Cable With Brass Washers Rebber Rings Complete Erected With Cable Ends & Leads Connected. , Supplying And Erecting Heavy Duty Siemens Type Brass Cable Glands For 3 1/2 X 120 Sq. Mm. To 3 1/2 X 240 Sq. Mm Pvc Armored Cable With Brass Washers Rubber Rings Complete Erected With Cable Ends & Leads Connected. , Supplying And Erecting Heavy Duty Siemens Type Brass Cable Glands For To 3 1/2 X 300 Sq. Mm Pvc Armored Cable With Brass Washers Rubber Rings Complete Erected With Cable Ends & Leads Connected. , Supply & Erecting Crimping Type Conforming To I.S. Suitable For Cable Up To 550 Sq. Mm. Evenly Crimped With High Pressure Tool & Connected To Switchgear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner. , Supplying & Erecting Crimping Type Aluminum Lugs Conforming To I.S. Suitable For Cable Up To 35 Sq.Mm. Evenly Crimped With High Pressure Tool & Connected To Switchgear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner. , Supplying & Erecting Crimping Type Aluminium Lugs Conforming To I.S. Suitable For Cable 50 Sq.Mm. Evenly Crimped With High Pressure Tool & Connected To Switchgear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner. , Supplying And Erecting Crimping Type Aluminium Lugs Conforming To I.S. Suitable For Cable 70 Sq.Mm. Evenly Crimped With High Pressure Tool & Connected To Switchgear Terminals With Brass / Cadmium Plated Nut Bolts In An Approved Manner. , Supplying And Erecting Pipe Type Earthing With 40Mm. Dia 2.5 Mtr.Long B Grade G.I. Pipe Or 20 Mm Dia. G.I. Rod Buried In Earth With Necessary Double G.I. Earth Wire No.8 Swg Complete Erected And Connected To Nearest Switchgears / Earth Terminal , Supplying & Erecting Gi Earth Wire 14 To 6 Swg Complete Erected With Gi Earth Wire On Wall &/Or Any Other Purpose With Necessary Cl S Fixed On Wall In An Approved Manner For Earthing Or Any Other Purposes. With Copper Lugs Cables Socket Of 30 More Ar Each End With Necessary Cadmium Plated Double Nuts & Bolts With Washers. , Carriage & Erection Of Steel Tubular Poles 8.50 Mtr. Long Including Foundations & Painting. (Poles & Junction Boxes Will Be Supplied By Rcf While Remaining Material & Hardware Shall Be Supplied By The Contractor. Erection As Per Relevant Isi Standard , Same As Above But For Poles Upto 4 To 5 Mts. Long. , Dismantling The Existing Pole Up To 6 M Height With Brackets, Cl S, Insulators, Stay From The Cement Concrete Foundation And Making The Site Clear By Refilling The Pits With Excavated Materials And Bringing It To The Ground Level , Dismantling The Existing Pole Above 6 M Height With Brackets, Cl S, Insulators, Stay From The Cement Concrete Foundation And Making The Site Clear By Refilling The Pits With Excavated Materials And Bringing It To The Ground Level. , Erection Of Departmentally Supplied Strret Light J.B. Including Connection And Hardware. , Erection Of Departmentally Supplied 32 / 63 Ictpn Switch 3 Phase, 400V/ Krone Box Up To 50 Pair Including Termination Of The Cable, Connection & Earthing The Same. , Erection Of Dept. Supplied 100/200/300A Ictpn Switch/Geyser/Motor Starter/100-400 Pair Kbx Box On The Exiting Frame Including Termination Of The Cable, Connection & Earthing The Same. , Supply Of Pvc Insulated Cu Condutor(Flexible),Industrial Cable Pvc Sheathed Cables ,1100 Volts To Is 694 3 Core 1.5 Sqmm. Make : Polycab/Finolex / Kei , Supply Of Pvc Insulated Cu Condutor(Flexible),Industrial Cable Pvc Sheathed Cables ,1100 Volts To Is 694 3 Core 2.5 Sqmm. Make : Polycab/Finolex / Kei , Supply Of Pvc Insulated Cu Condutor(Flexible),Industrial Cable Pvc Sheathed Cables ,1100 Volts To Is 694 4 Core 1.5 Sqmm. Make : Polycab/Finolex / Kei , Supply Of Pvc Insulated Cu Condutor(Flexible),Industrial Cable Pvc Sheathed Cables ,1100 Volts To Is 694 4 Core 2.5 Sqmm. Make : Polycab/Finolex / Kei , Supply & Erecting Acrylic Sheet Of Size 3Mm Thick To Be Used For Covering Crca Sheet Bixes Etc Including Cutting,Drilling, & Oasting Or Fixing With Nut Bolts/Screw Complete , Providing & Fixing Of Frp Street Light Junction Box Of Ip 66 Or Above, Rybn Connection Studs Or 6X4x4 Street Light Metal Pole Boxes , Upto 4 Core Above 16 Sq.Mm Up To 50 Sq.Mm , Upto 4 Core 50 Sq.Mm Up To 120 Sq.Mm , Upto 4 Core 120 Sq.Mm Up To 240 Sq.Mm , Upto 4 Core 240 Sq.Mm Up To 400 Sq.Mm , Supplying & Erecting Modular Type Switch 6A / 10A Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Modular Type Bell-Push 6A / 10A Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Modular Type 3 Pin 6A /10A Socket Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Modular Type 3 Pin 6A / 16 Or 20A Combined Unit Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Modular Type Electronic Dimmer / Step Type Regulator, Two Module Isi Mark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Repairs / Rewinding Of Celing Fan Of 1200 Mm Sweep , Replacement Of Bearings Of Celing Fan With 1200Mm Sweep , Earthing Station With 600 Mm X 600 Mm X 6 Mm Galvanisediron Plate & 50 Mm Dia. G.I. Pipe, 3000Mm Long Gi Pipe(Class B Or Better) Earth Pit As Per Is 3043. The Earth Pitshall Be Provided With Watering Pipe (Class B) With Wiremessed Funnel, 25X3 Gi Strip / 8 Swg Gi Wire Up To Chamber(Wire Or Strip Size As Per Fault Level), Disconnecting Links With600 X 600 Mm (Clear) Rcc Chamber & Heavy Duty 3Mm Thickci Chequered Plate Cover With Hinge & Stainless Steel Bolts.Bentonite/ Charcol & Salt Shall Be Provided For Earth Pits.Excavation, Backfilling, Removal Of Excess Soil Is Included Inthe Scope , Point Wiring In Concealed Manner With Pvc Conduit. Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bellpoint With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Single Core Cable In Concealed Manner In Heavy Duty Pvc Conduit, With Modular Switch, Modular Plate, Suitable Ms Box, Ceiling Rose And Earthing The Point With 1.5 Sq.Mm. Fr Pvc Insulated Copper Conductor Single Core Cable Etc As Required. (From Switch/ Taping To Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point). Pref Make : Polycab / Finolex/Kei , Short Points ( From 0-3Mtrs : Distence From Switch / Taping To Point ) , Medium Point (From 3 Mtrs To 6Mtrs : Distence From Switch / Taping To Point ) , Long Points( From 6-10 Mtrs : Distence From Switch / Taping To Point ) , 20Mm , 25Mm , 32Mm , 40Mm , 50Mm , 2 X 1.5 Sq. Mm , 3 X 1.5 Sq. Mm , 3 X 2.5 Sq. Mm , 3 X 6 Sq. Mm , 4 X 6 Sq. Mm , Short Points ( From 0-3Mtrs) (2C / 3C X 1.5 Sqmm ) , Medium Point (From 3 Mtrs To 6Mtrs) (2C / 3C X 1.5 Sqmm ) , Long Points( From 6-10 Mtrs) (2C / 3C X 1.5 Sqmm ) , 15 /16A Power Point Using 3 C X 2.5 Sqmm Wires Of Mentioned Make. (6-12 Meter) , 1 Or 2 Module , 4 Module , 6 Module , 8 Module , 12 Module /18 Module , 8 Way Spn Db , 12 Way Spn Db , 16 Way Spn Db (4 + 12Way) , Tpn Db (8 + 12Way) , Fixing Of 2X2 Led / Mirror Optic Fiting With Independent Support. Removal Of Existing 2 X 2 4X18w T/L/ Led Fitting From Falls Celing With Disconnection & Determination Of Connections. Supply And Fixing Of 4 Nos Of J Screw Type Hooks / Angle Fasteners On The Celing & Gi Wire For Fixing Of Fittings. Installation Of Removed Above Said Fittings On Newly Installed J Hooks / Angle Fastener With Gi Wire Up To Falls Celing & Termination To Existing Connection. , Normalising Road After Cable Laying: Nominal Mix Of 1:2:4 (1Cement:2 Coarse Sand: 4 Graded Stone Aggregate 20Mm Nominal Size. , Supplying And Fixing Of 15A Combination Of Anchor/ L&T / Legrand/ Schneider Etc. , Supply And Laying Of Pvc Trunking-25Mm Size , Supply And Laying Of Pvc Trunking-50Mm Size , Supply And Erection Of Socket - Step Type Electronic Regulator , Supply And Erection Of 8 - 9W Led Bulb Of Make Havells/Crompton/ Surya/Polycab/Philips/Wipro. , Supply And Erection Of 12 - 15W Led Bulb Of Make Havells/Crompton/ Surya/Polycab/Philips/Wipro , Supply And Erection Of Led Tube Light Batten Of 2Ft Of Make Havells/Crompton/ Surya/Polycab/Philips/Wipro , Supply And Erection Of Led Tube Light Batten Of 4Ft Of Make Havells/Crompton/ Surya/Polycab/Philips/Wipro , Supply And Erection Of Led Square Fitting Of Make Havells/Crompton/ Surya/Polycab/Philips/Wipro. (10-15 W) (75 Mm X75 Mm) , Making Trench In Soft Soil With A Width Up To 2 Ft, Depth Of 4Feet. Back Filling Shall Also Be Included. , Making Trench In Hard Soil With A Width Up To 2 Ft, Depth Of 4Feet , Supply And Erection Of 100W Led Flood Light Of Colour White/Yellow/Blue Or Any Other Colour : Make Havells/Crompton/ Surya/Polycab/Philips/Wipro Etc. Flood Light Shall Be With Lens Or With Suitable Replector. , Supply And Erection Of 50W Led Street Lights With Peanut Lences Of Make Havells/Crompton/ Surya/Polycab/Philips/Wipro. Fitting Shall Be Of Pipe Mounted. , Laying Of Bricks On Cable In Lenth Wise. , Laying Of Full Hume Pipe Of Size Six Inche , Supply And Erection Of 20W Led Street Lights With Peanut Lences Of Makehavells/Crompton/ Surya/ Polycab/Philips / Wipro. , Supply And Erection Of 16A - 25 A, 30Ma Rcbo, 2 Pole Of Make Legrand/ L&T/Havells/Hager. , Supply And Erection Of 32/40A, 30Ma Rcbo, 2Pole Of Make Legrand/ L&T/Havells/Hager , Supply And Errection Of Celing Rose / Square Box/All Types Of Holder , Wall Mounting Fan - 400Mm Sweep. Make : Bajaj / Almonard / Crompton Greaves / Havells / Orient , Pedestrial Fan With A Sweep Of 400 Mm. Make : Bajaj / Almonard / Crompton Greaves / Havells / Orient , Supply And Laying Of 3C X 2.5 Sqmm Armoured Xlpe Cable Of Pref Make Polycab / Finolex /Kei , Supply And Laying Of 3C X 6 Sqmm Armoured Xlpe Cable Of Pref Make Polycab / Finolex/Kei , Supply, Installation Of Metalic Industrial Ac Boc With Suitable 20A Plug With Metal Clad Plug Top Without Mcb. Make : Anchor / Havells / Reyrole / Havells / Poly Cab / Legrand. , Supply Of Suitable Welding Machine With Skilled Operator Or Welder .( For 8 Hr) , Supply Of Suitable Ms Angles And Fabrication Of The Same , Supply Of Suitable Ms I - Channel And Fabrication Of The Same , Supply And Laying Of Gi Earthing Pattie With Suitable Cl S. Width : 25Mm To 100 Mm& Thickness : 3 Mm - 10Mm , Supply On Hiring Basis, Installation Of 100 To 150 Led Fittings With Required Wires / Cables , Supply, Installation And Commissioning Of 12 To 15 W Led Circular Downlighter Of Suitable Size To Existing Cut-Out Make : Havells / Cg/Polycab/Fiem / Wipro / Philiphs , Supply, Installation And Commissioning Of 12 To 15 W Led Circular Downlighter / Surface Mount Of Make : Havells / Cg/Polycab/Fiem / Wipro / Philiphs , Supply Of Led Square Fitting Of Approximate Size 300 Mm X 300 X300 Mm Square Downlighter / Surface Mount Led Fitting Of Make Havwlls / Cg/Polycab/Fiem / Wipro / Philiphs. Wattage : Up To 15 - 22 W , Supply Of Led Square Fitting Of Approximate Size 600 Mm X 600 Mm Square Downlighter / Surface Mount Led Fitting Of Make Havwlls / Cg/Polycab/Fiem / Wipro / Philiphs. Wattage : Up To 15 - 22 W , Replacement Of Existing 5 / 6 A Switch / Bell Push Piano Switch With New Anchor / Legrand/ L & T Make 5 / 6 A Switch. Cost Shall Include Replacement Of Old Switch Also , Replacement Of Existing 5 / 6A Plug With New Anchor / Legrand/ L & T Make 5A Plug. Cost Shall Include Replacement Of Old Plug Also , Supply. Installation And Commissioning Of 100A 4 Pole Mcb Isolator Of Make L & T, Legrand/Anchor/ Hager , Supply. Installation And Commissioning Of 63A, 3 Pole Isolator Of Make L & T, Legrand/Anchor/ Hager , Supply, Installation And Commissioning Of Switch Disconnector Fuse (Sdf) - 125 A With Ms Enclosure. Same Shall Be Supplied With Suitable Fuses. Make : L & T, Kew, Havels . C &S , Supply, Installation And Commissioning Of Switch Disconnector Fuse (Sdf) - 63 A With Ms Enclosure. Same Shall Be Supplied With Suitable Fuses. Make : L & T,Havels , Supply, Installation And Commissioning Of Switch Disconnector Fuse (Sdf) - 250A / 260 Awith Ms Enclosure. Same Shall Be Supplied With Suitable Fuses. Make : L & T, Kew, Havels . C &S , Supply, Installation And Commissioning Of 16 /20 A Modular Switch Of Make Hifi / L & T/Havells / Roma , Supply, Installation And Commissioning Of 16 /20 A Modular Socket / 16-5A Combination Modular Socket Of Make Hifi / L & T/Havells / Roma , Supply, Installation And Commissioning Of 25 A Modular Switch Of Make Hifi / L & T/Havells / Roma , Supply, Installation And Commissioning Of 25 A Modular Socket Of Make Hifi / L & T/Havells / Roma , Industrial Plug Top For Ac Box Of Rating 16A Suitable For Existing Ac Box , Supply, Installation And Commission Of L&T Make Sdf Of 400 A , Supply, Installation And Commissioning Of L&T Hn Fuses-63 A, Size 000 , Supply, Installation And Commissioning Of L&T Hn Fuses-80 A, Size 000 , Supply, Installation And Commissioning Of L&T Hn Fuses-100 A, Size 000 , Supply, Installation And Commissioning Of L&T Hn Fuses-125 A, Size 000 , Supply, Installation And Commissioning Of L&T Hn Fuses-160 A, Size 00 , Supply, Installation And Commissioning Of L&T Hn Fuses-125 A, Size 0 , Supply, Installation And Commissioning Of L&T Hn Fuses-160 A, Size 0 , Supply, Installation And Commissioning Of L&T Hn Fuses-250 A, Size I , Supply, Installation And Commissioning Of L&T Hn Fuses-315 A, Size 1 , Supply, Installation And Commissioning Of L&T Hn Fuses-400 A, Size Ii , Supply, Installation And Commissioning Of L&T Make Cylindrical Type Fuse Link Hf63a. , Supply & Erecting Mains In Provided Concealed / Open Conduit Or Equivalent With 3C X 4 Sqmm F R Standard/Solid Copper Pvc Insulated Wire Of Polycab / Finolex , Supply, Installation And Commissioning Of 40 - 63 A, Double Pole Mcb Of B Curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, Abb, Orient Electric, Eaton, Hager , Supply, Installation And Commissioning Of Up To 32A, Double Pole Mcb Of B Curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, Abb, Orient Electric, Eaton, Hager , Supply, Installation And Commissioning Of 63A, Three Pole Mcb Of B Curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, Abb, Orient Electric, Eaton, Hager, C&S Electric , Supplying, Erercting & Marking Miniature Circuit Breaker Conforming To Is:8828 Of 1996) Single Pole 16 - 32- B Series (Lighting) With Required Wiring Connections And Lugs Etc. In Provided Distribution Board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, Abb, Orient Electric, Eaton, Hager , Supplying, Erercting & Marking Miniature Circuit Breaker Conforming To Is:8828 Of 1996) Single Pole 40 To 63- B Series (Lighting) With Required Wiring Connections And Lugs Etc. In Provided Distribution Board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, Abb, Orient Electric, Eaton, Hager , Supply And Fabrication Of Class C Gi Pipe Of Different Od (Suitable To Base Fittings) To Streetlight Poles, Garden Light Poles Etc. Scope Shall Also Include Painting Of 1 Coat Fprime With 2 Coat Of Silver Colour, , Supply, Installation And Commissioning Led Garden Light (Post Top Lantern) Of 25W, Suitable For 75 Mm Od Pipe, Clear Diffuser Housing : Powder Coated Aluminum Die Cast And Spun Aluminum. Makes : Havells, Fiem, Polycab. Picture Is Attached For Reference, , Supply And Fixing Of Suitable Fan- Down Road.( Length May Vary Up To 3 Ft ). , Supply, Installation And Commissiong Of Gi Busbar ( Hot Dip) For Earthing Connection. (Size : 34 Mm (L) X 50 Mm (W) X6 Mm ) Busbar Shall Have Six No Holes And Be Provided With Suitable Stainless Steel Nut Bolts For Taping Connections. , Constructing 230 Mm Thick Brick Masonry Chamber 600(Length)X600(Width)X4500 (Depth) Around The Electrode As Per Approved Drawing. , Supply And Installation Of Ci Hinged Cover (Minimum 5 Mm Thickness) For Earth Pits Of Clear Opening 450 Mm X 450 Mm, As Per Scope Of Work , Letter Writing On Earth Pits Cover As Per Approved Format For Identifications As Instructed By Rcf Engineer-In-Charge. (Resistance Value, Test Date And Pit Identification No - As Provided By Rcf. ) , Preperation Of Layout Of Cable Laying (Up To 500 Meter) / Substations / Etc In Autocad Or Equivalent Software And Submitting The Same As Per Instruction By Site In Charge, Prepred Lay-Out Shall Clearly Indicate Buildings And Roads As Applicable. Drawing Shall Be Submitted In A0 Or A1 Sheet In Triplicate. , Supply Instalation And Commissioning Of Modular Sp Mcb Of Rating Up To 25 A. , 20 Hp Motor Shifting, Raising, Or Lowering Utilizing A Cahiin Pulley Block, D Shackle, Sling Rope Etc. The Bidder Must Provide A Minimum Of Four Skilled Riggers Along With The Necessary Lifting Equipment, Such As Chain Pulley Block, D Shackle, And Sling Ropes. , Supply And Installation Of Good Quality Finished 3 Mm Ss Plate With Raceway Junction Box Frame (Plate Size Upto 13.5 × 13.5 Inches, Frame Size Upto 93 × 39 Cm) With Required Hardware For Concealed Metal Race Way Junction Boxes For Proper Support With Floor And Face To Face Matching With Floor , Supply, Carriage, Installation And Commissioning Of 28W, 1200 Mm, Double Ball Bearing, Three Blade Bldc Ceiling Fan. Rated Air Delivery Shall Be 280 Mm Or Better. Speed Control – 5 Speed Control With Remote (Shall Be Supplied With The Fan) / With Step Type Regulator. Colour Shall Be Finalized By Site-In-Charge As Per Requirement. Type Test Certificate From Nabl Approved Lab. , Van Mounted Articulator For Street Light Job/ Hydra For Lifting 1.5 Ton On Hiring For 8 Hr. , Loading Or Unloading Of Three-Phase Induction Motors Ranging From 10 Hp To Less Than 30 Hp (No Chain Block/Hoist Is Available In The Pump House Or Warehouse). Scope Includes The Safe Loading And Unloading Of Induction Motors From The Foundations (Pump House) To The Designated Tranpriyadarshini & Admin. Bldg Vehicle (And Vice Versa) By Opening The Coupling And Removing The Connection And Termination Of The Cable. While Unloading, The Scope Shall Also Include Installing The Motor On The Designated Foundation. Equipment: The Contractor Shall Deploy Appropriate, Load-Tested Lifting Gear, Including But Not Limited To Tripods, Chain Blocks, Manual/Electric Hoists, Or Mobile Cranes, Depending On Site Constraints And Motor Weight. The Contractor Shall Exercise Extreme Caution To Prevent Any Damage To Existing Site Infrastructure, Including Nearby Pipelines, Cable Trays, Instrument Cables, And Structural Members. Motors Must Be Handled To Avoid Impact On The Cooling Fan Covers, Terminal Boxes, And Shaft Ends. , Loading Or Unloading Of Three-Phase Induction Motors Ranging From 30 Hp To 50 Hp (No Chain Block/Hoist Is Available In The Pump House Or Warehouse). Scope Includes The Safe Loading And Unloading Of Induction Motors From The Foundations (Pump House) To The Designated Tranpriyadarshini & Admin. Bldg Vehicle (And Vice Versa) By Opening The Coupling And Removing The Connection And Termination Of The Cable. While Unloading, The Scope Shall Also Include Installing The Motor On The Designated Foundation. Equipment: The Contractor Shall Deploy Appropriate, Load-Tested Lifting Gear, Including But Not Limited To Tripods, Chain Blocks, Manual/Electric Hoists, Or Mobile Cranes, Depending On Site Constraints And Motor Weight. The Contractor Shall Exercise Extreme Caution To Prevent Any Damage To Existing Site Infrastructure, Including Nearby Pipelines, Cable Trays, Instrument Cables, And Structural Members. Motors Must Be Handled To Avoid Impact On The Cooling Fan Covers, Terminal Boxes, And Shaft Ends. , Carrying The Departmentally Supplied Industrial Extension Board With Rcbo/ To The Designated Place With In The Priyadarshini & Admin. Bldg, Checking, Repairing, Testing, And Energising By Connecting The Incoming Supply By A Licensed Electrician. Scope Shall Also Include De-Energising The Above-Mentioned Board By Disconnecting The Supply And Carrying The Board Back To The Designated Place In The Priyadarshini & Admin. Bldgs Club. Minor Consumable Materials Need To Be Arranged By The Contractor. It May Be Noted That Tripping Of The Rcbo Against Leakage Current Must Be Ensured. , Preventive Maintenance Of The A Three-Phase Induction Motors Up To 10 Hp Coupled With A Centrifugal Pump Assembly, Including All Labour, Specialised Tools, And Consumables; The Scope Shall Include Measurement Of Insulation Resistance (Ir) Using A 500V/1000V Megger; Checking And Tightening Of All Terminal Connections; Inspection Of The Cooling Fan; Cleaning Of Motor Fins For Heat Dissipation; Regressing Of The Motor; Inspection Of Foundation And Coupling Bolts; Replacement Of The Foundation Bolts If Required; And Inspection Of The Alignment With The Pump. Post-Maintenance Recording Of No-Load And Load Current In Normal Operating Conditions Shall Also Be Covered In The Scope. A Detailed Service Report Shall Be Prepared And Submitted. , Preventive Maintenance Of The A Three-Phase Induction Motors (15 Hp – 50 Hp ) Coupled With A Centrifugal Pump Assembly, Including All Labour, Specialised Tools, And Consumables; The Scope Shall Include Measurement Of Insulation Resistance (Ir) Using A 500V/1000V Megger; Checking And Tightening Of All Terminal Connections; Inspection Of The Cooling Fan; Cleaning Of Motor Fins For Heat Dissipation; Regressing Of The Motor; Inspection Of Foundation And Coupling Bolts; Replacement Of The Foundation Bolts If Required; And Inspection Of The Alignment With The Pump. Post-Maintenance Recording Of No-Load And Load Current In Normal Operating Conditions Shall Also Be Covered In The Scope. A Detailed Service Report Shall Be Prepared And Submitted. , Attending To No-Light Complaints, Electrical Shock Reports, Earth Leakage Complaints, And General Circuit Failures On A Standalone Basis. The Scope Includes Fault Identification, Isolation Of Defective Segments, And Restoration Of Power. Fault Identification: Systematic Tracing Of Circuits To Identify Short Circuits, Open Circuits, Earth Leakage (Causing Shocks), Or Neutral Failures Using Calibrated Multimeters/Insulation Testers. Identified Faults Shall Be Rectified By Re-Termination Of Loose Connections At Dbs, Switches, Or Fixtures; Cleaning Of Carbonised Contacts; And Bypassing Or Replacing Minor Defective Wiring Segments. Provision Of All Minor Materials Required For The Fix, Including But Not Limited To: Pvc Insulation Tape, Wire Ferrules, Rawl Plugs, Screws, Cable Ties, And Short Lengths Of Connecting Wire. , Supply Laying And Termination Of Single Core Al Unarmoured Earthing Cable Upto 16 Sq Mm , Supply Laying And Termination Of Single Core Al Unarmoured Earthing Cable Upto 35 Sq Mm , Supply Laying And Termination Ofsingle Core Al Unarmoured Earthing Cable Upto 70 Sq Mm , Supply, Fabrication, And Installation Of Gi Perforated-Type Cable Tray Of Size Size 50 Mm Width X 50 Mm Depth X 2500 Mm With 2.5 Mm Thickness. The Tray Supplied Shall Be Accessories And Hardware Like Nut Bolts, Washers, Fixing Cl S, Bends, Joints, Etc. , Supply, Fabrication, And Installation Of Gi Perforated-Type Cable Tray Of Size Size: 150 Mm Width X 50 Mm Depth X 2500 Mm Length With 2.5 Mm Thickness. The Tray Supplied Shall Be Accessories And Hardware Like Nut Bolts, Washers, Fixing Cl S, Bends, Joints, Etc. , Supply, Fabrication, And Installation Of Gi Perforated-Type Cable Tray Of Size Size: 300 Mm Width X 50 Mm Depth X 2500 Mm Length With 2.5 Mm Thickness. The Tray Supplied Shall Be Accessories And Hardware Like Nut Bolts, Washers, Fixing Cl S, Bends, Joints, Etc. , Connection Of 2 Or 3 Core Cables To The Provided Rcbo Extension Board / Arranging Temporary Supply With Departmentally Provided Components / Installing Or Removing Departmentally Supplied Hf Or Hn Fuses / Checking Tightness Of Termination / Busbar / Insulation / Or Similar Miscellaneous Electrical Jobs. An Appropriate Fuse Puller Arrangement Shall Be In The Scope Of The Contractor. (The Job Has To Be Carried Out By Licensed Technicians Only; A Helper Also Must Be Deployed To Support The Licensed Technician. If Instructed, The Contractor Must Ensure The Availability Of The Required Manpower As Directed.) :Standalone Item , Installation, Testing And Commissioning Of Supplied Ms Meter Box Of 1200 Mm X 850 Mm X 250 Mm, Approximate Weight 85 To 100 Kg. Scope Shall Also Include Termination Of 4/3.5 C X 35/70 Sq Mm Al Cable, Termination Of 6 No Service Mains, Installing Departmentally Supplied 2 Model Rcbos, Labelling Of All Mcbs, Energy Meters, Etc. Pvc Conduits Through Which Service Mains Are Laid Shall Be Terminated With Suitable Glands. All Redundant Openings Shall Be Closed. , Supply Installation Of 1200 Mm Ceiling Fan 3 Blades Set Suitable For Usha, Bajaj Orient , Supply Installation Of 1200 Mm Ceiling Fan 2 Caps Set Suitable For Usha, Bajaj Orient , Supply Installation Of 1 Watt Coloured Led Night L , Preventive Maintenance Of The Drum Assembly, Rope Assembly Adjustment And Their Alignment, Greasing/Oiling Of Motor, Gearbox, Drum, Rope, Chain, And Proper Alignment Of Head Frame And Lantern Ring If It Found Tilt Etc. To Make Ease In Operation Of 12.5 M High Mast Tower. (Supply Od Consumables Like Grease /Winch Gear Oil/Wire Rope Lubricant/Cotter Pins & Fastners/Contact Cleaner/Gland Packing/Sealants/Micro Fiber Cloths/Scrubbers, Cotton Waste /Rags Shall Be The Sole Responsibility Of The Contractor.) This Activity Is Standalone, And No Minimum Quantity Is Guarenteed , Replacement Of Lighting Fixtures Of The 12.5-M High Mast: Scope Shall Include Carrying The Departmentally Supplied Light Fixture From The Departmental Office To The Site Within The Priyadarshini & Admin. Bldg And Operating The High Mast Motor And Lowering The Lantern Ring Assembly Safely To Replace The Fitting. Old Fittings Shall Be Carried Back To The Department. This Activity Is Standalone, And No Minimum Quantity Is Guarenteed , Replacement Of Lighting Fixtures Of The Street Light Poles Up To A Height Of 7.5 Metres. Scope Shall Include Carrying The Departmentally Supplied Borrage Light Fixture / Street Light From The Departmental Office Or Store Within The Priyadarshini & Admin. Bldg Area To The Site Within The Priyadarshini & Admin. Bldg And Safely Replace The Fitting With A Departmentally Supplied Wheel Ladder / Articulator. Tranpriyadarshini & Admin. Bldgation Of The Wheel Ladder Shall Be The Responsibility Of The Bidder. Old Fittings Shall Be Carried Back To The Department. , Preventive Maintenance / Inspection / Fault Finding Of A Street Light Pole Under A Substation Or Timer Box: The Scope Includes Inspecting And Preparing A Report On Whether Street Light Poles Are Functional, Identifying, Isolating And Rectifying If There Is Any Fault. Scope Shall Include Checking Of Pole Junction Boxes, Cables, Terminations Or Light Fixtures With Appropriate Manpower/Tools, Etc. On An Incident/Event Basis. , Maintenance Of The Street Light Pole: The Scope Includes Maintenance Of The Built-In Junction Box By Replacing The Stud Connector, Replacement Of The Gasket To Improve Ip, Replacement Of The Damaged Flexible Cable (Supplied By The Department), Cleaning Of Fixtures, And Checking/Testing Of The Poles Working Condition With Appropriate Manpower/Tools, Etc., On A Daily Basis. The Articulator/Ladder Will Be Arranged By The Department. , De-Coiling / Coiling Of The Cables Upto 4C X 35 Sq Mm Xlpe, 1.1 Kv Cable : Systematic Decoiling Of Electrical Cables From Drums. The Contractor Shall Provide And Utilise Certified Cable Drum Jacks (Hydraulic Or Mechanical) Of Adequate Capacity To Ensure Smooth Rotation And Prevent Kinking Or Insulation Damage. Coiling Shall Include The Orderly Coiling, Bundling, And Tagging Of All Surplus Or Recovered Cable Lengths For Return To The Designated Site Area. , De-Coiling / Coiling Of The Cables 4Cx50 - 4C X 90 Sq Mm Xlpe, 1.1 Kv Cable : Systematic Decoiling Of Electrical Cables From Drums. The Contractor Shall Provide And Utilise Certified Cable Drum Jacks (Hydraulic Or Mechanical) Of Adequate Capacity To Ensure Smooth Rotation And Prevent Kinking Or Insulation Damage. Coiling Shall Include The Orderly Coiling, Bundling, And Tagging Of All Surplus Or Recovered Cable Lengths For Return To The Designated Site Area. , De-Coiling / Coiling Of The Cables 4Cx120 - 4C X 240 Sq Mm Xlpe, 1.1 Kv Cable : Systematic Decoiling Of Electrical Cables From Drums. The Contractor Shall Provide And Utilise Certified Cable Drum Jacks (Hydraulic Or Mechanical) Of Adequate Capacity To Ensure Smooth Rotation And Prevent Kinking Or Insulation Damage. Coiling Shall Include The Orderly Coiling, Bundling, And Tagging Of All Surplus Or Recovered Cable Lengths For Return To The Designated Site Area. , De-Coiling / Coiling Of The Cables 4Cx300 - 4C X 400 Sq Mm Xlpe, 1.1 Kv Cable : Systematic Decoiling Of Electrical Cables From Drums. The Contractor Shall Provide And Utilise Certified Cable Drum Jacks (Hydraulic Or Mechanical) Of Adequate Capacity To Ensure Smooth Rotation And Prevent Kinking Or Insulation Damage. Coiling Shall Include The Orderly Coiling, Bundling, And Tagging Of All Surplus Or Recovered Cable Lengths For Return To The Designated Site Area. , Preventive Maintenance And Up Keeping Of Lt Switchgear Panels & Distribution Boards :A. Visual & Physical Inspection: Detailed Assessment Of Panel Enclosures For Structural Integrity And The Condition Of Cable Entry Glands, Terminations, And Terminal Lugs. The Contractor Shall Ensure All Connections Remain Tight. B. Verification Of The Operational Status Of All Analogue/Digital Meters, Selector Switches, And Led Indication L S. Faulty Indicators Or Non-Functional Meters Must Be Reported For Immediate Rectification.C. Recording Of Electrical Parameters And Thermal Monitoring Of Busbar Joints, Lugs, And Terminations Using A Non-Contact Infrared (Ir) Temperature Gun. D. Servicing Of Panel Doors And Locking Mechanisms, Including Cleaning And Greasing Of Hinges/Latches.E. General Cleaning Of The Panel And Panel Room, Including Cobweb Removal, Ensuring The Floor Area Is Kept Clear Of Scrap Or Hazardous Materials To Maintain Safe Working Clearances. , Carriage Of Departmental Material, Including Cable Of Weight Up To 50 Kg, Safely From A Departmental Office Or Cable Yard Or Any Other Designated Point In The Priyadarshini & Admin. Bldg To Another Designated Place Within The Priyadarshini & Admin. Bldg And Vice Versa. The Scope Shall Include Loading And Unloading And Arrangement Of A Handcart Or Truck As Per Requirement. , Carriage Of Departmental Material, Including Cable Of Weight Up To 500 Kg, Safely From A Departmental Office Or Cable Yard Or Any Other Designated Point In The Priyadarshini & Admin. Bldg To Another Designated Place Within The Priyadarshini & Admin. Bldg And Vice Versa. The Scope Shall Include Loading And Unloading And Arrangement Of A Handcart Or Truck As Per Requirement. , Carriage Of Departmental Material, Including Cable Of Weight Up To 1000 Kg, Safely From A Departmental Office Or Cable Yard Or Any Other Designated Point In The Priyadarshini & Admin. Bldg To Another Designated Place Within The Priyadarshini & Admin. Bldg And Vice Versa. The Scope Shall Include Loading And Unloading And Arrangement Of A Handcart Or Truck As Per Requirement. , Loading Or Unloading Of The Department Material Or Scrap From The Electrical Store / Scrap Yard / Plant Area Up To 500 Kg Within The Rcf Factory Premise Or Priyadarshini Or Priyadarshini & Admin. Bldg Area With A Departmentally Provided Truck. All Tools, Tackles And Ppe Shall Be Ensured By The Contractor. , Connecting Copper Cable Of Size Up To 4 C X 16 Sqmm By Supplying And Crimping Suitable Copper Lugs , Carriage,Installation And Commissioning (Removal) Of Departmentally Supplied Bay Light Or Equivalent Up To Height Of 5 Mtrs Directly On Ceiling Or Wall.Materials Like Cl Screw, Square Box Etc With Consumables Shall Be Supplied By The Contractor , Painting Of Garden Ligth Pole Ms/Gi Of Height 7 Feet Above The Ground With Od Of 40 Or 50 Mm By Removing Rust And With Two Coats Of Silver Paint , Carriage, Installation And Commissioning Of A Decorative Light Pole/Gi Pole Up To The Height Of 7.5 Meters On A Provided Foundation Or Base Plate.The Scope Shall Also Include The Assembling Of The Bracket/ Fitting, Jb And Running The Provided Cable Through The Pole From Jb To The Fitting , Supply & Replacement Of Pvc Board Of 4 X 4 . Make : Presto, Pressfit, Gold Medel , Supply & Replacement Of Pvc Board Of 4 X 7. Make : Presto, Pressfit, Gold Medel , Supply & Replacement Of Pvc Board Of 6 X 8. Make : Presto, Pressfit, Gold Medel , Supply & Replacement Of Pvc Board Of 8 X 10. Make : Presto, Pressfit, Gold Medel , Supply & Replacement Of Pvc Board Of 10 X 12. Make : Presto, Pressfit, Gold Medel , Supply, Installation And Commissioning Of Decorative Wall Mounted Dual-Light Vanity Luminaire In Priyadarshini & Admin. Bldg: Dual-Light Vanity Fitting With Matte Black /Bronze Finish Metal Body And Cylindrical Frosted Glass Shades. To Include All Mounting Hardware And Internal Wiring. Approval Must Be Taken From Site-In-Charge Before The Intallation And Commissioning. , Supply, Installation, And Commissioning Of A Decorative Wall-Mounted Lantern Featuring A Traditional Coach Silhouette With An Industrial Aesthetic. The Fixture Shall Consist Of A Gooseneck Support Arm, A Conical Ventilated Cap, And A Flared Cage Housing A Clear Glass Diffuser. , Providing And Installing Decorative Series L S Complete With Connections, Testing Etc. At Various Locations On Lawns, Buildings And Gates Etc Of Priyadarshini & Admin. Bldglows, Priyadarshini & Admin. Bldg Qty - 10000. , Providing And Installing Decorative Running Strip L S Pattis Of 300 L Complete With Connection. Testing Etc.. At Various Locations On Lawns, Of Priyadarshini & Admin. Bldg Etc. , Providing And Installing Decorative Rice L , Complete With Connections, Testing Etc. At Various Locations On Lawns,And Gates Etc Of Priyadarshini & Admin. (Unit Rate Quoted Shall Be For 100 Nos Per Day) , Identifying Under Ground Power Cable / Metalic Pipe Line With Emf Locator Etc And Giving Clearence For Digging
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supplying & laying PVC trunking (PVC casing-n-capping) of size 20 mm with double locking arangement with grooves, trunking of size not below 12.5 mm. in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. | Supplying & laying PVC trunking (PVC casing-n-capping) of size 20 mm with double locking arangement with grooves, trunking of size not below 12.5 mm. in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. |
| 2 | Supplying & laying PVC trunking (PVC casing-n-capping) of size 25 mm with double locking arangement with grooves, trunking of size not below 12.5 mm.in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick,duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. | Supplying & laying PVC trunking (PVC casing-n-capping) of size 25 mm with double locking arangement with grooves, trunking of size not below 12.5 mm.in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick,duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. |
| 3 | Supplying & laying PVC trunking (PVC casing-n-capping) of size 32 mm with double locking arangement with grooves, trunking of size not below 12.5 mm in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. | Supplying & laying PVC trunking (PVC casing-n-capping) of size 32 mm with double locking arangement with grooves, trunking of size not below 12.5 mm in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick, duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. |
| 4 | Supplying & laying PVC trunking (PVC casing-n-capping) of size 40 mm with double locking arangement with grooves, trunking of size not below 12.5 mm. in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick,duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. | Supplying & laying PVC trunking (PVC casing-n-capping) of size 40 mm with double locking arangement with grooves, trunking of size not below 12.5 mm. in height and thickness not below 1.2 mm. As per IS 14927 Part-I of 2001 and with accessories of PVC/resin polyproelyne not below 1.8 mm thick,duly embossed the name, duly sealed at joints and erected on wall/ceiling with necessary nettle fold G.I screws fixed at intervals not more than 500mm rawl plugs complete. |
| 5 | Scrapping existing paint of feeder pillar/switch gears(only outside) and frame of panel board completely without damaging and painting the same with single coat of Red oxide & two coats of approved quality enamel paint in an approved manner. (The square metre area of angle iron frame on which the switch- gears are erected shall be considered for measurement purpose) red oxide & enamel paint is in party's scope (rate is in sq.m) | Scrapping existing paint of feeder pillar/switch gears(only outside) and frame of panel board completely without damaging and painting the same with single coat of Red oxide & two coats of approved quality enamel paint in an approved manner. (The square metre area of angle iron frame on which the switch- gears are erected shall be considered for measurement purpose) red oxide & enamel paint is in party's scope (rate is in sq.m) |
| 6 | Supplying and fixing condensor 2 / 1.85/2.25 micro farad for ceilling fan. | Supplying and fixing condensor 2 / 1.85/2.25 micro farad for ceilling fan. |
| 7 | Supply & replacement of wooden /other approved material board 4''x4'' | Supply & replacement of wooden /other approved material board 4''x4'' |
| 8 | Supply & replacement of wooden / other approved board of 4\\" to 7\\" | Supply & replacement of wooden / other approved board of 4\\" to 7\\" |
| 9 | Supply & replacement of wooden / other approved boardboard 8\\" to 10\\" | Supply & replacement of wooden / other approved boardboard 8\\" to 10\\" |
| 10 | Supply & replacement of wooden / other approved board board 10\\" x 12\\" | Supply & replacement of wooden / other approved board board 10\\" x 12\\" |
| 11 | Supplying and erecting plan pendent type backellite lamp holder complete erect at position with necessary length of twin flexible wire( upto 1 Mtr.) | Supplying and erecting plan pendent type backellite lamp holder complete erect at position with necessary length of twin flexible wire( upto 1 Mtr.) |
| 12 | Supply & fixing of Ding-dong bell | Supply & fixing of Ding-dong bell |
| 13 | Supplying and erecting GLS lamp 230V,60 / 100 W. | Supplying and erecting GLS lamp 230V,60 / 100 W. |
| 14 | Making trench in Hard murum / Tar road of suitable width of 0.9 m deep for laying provided L.T. cable. Half round hume pipe of 150 mm placed length wise on top of the cable all over the run and back filling theexcavated earth without stones or hard material and making the surface proper with 15 cms. Crown on the top. (As per IS 1255) (rate per meter) | Making trench in Hard murum / Tar road of suitable width of 0.9 m deep for laying provided L.T. cable. Half round hume pipe of 150 mm placed length wise on top of the cable all over the run and back filling theexcavated earth without stones or hard material and making the surface proper with 15 cms. Crown on the top. (As per IS 1255) (rate per meter) |
| 15 | Laying of PVC cable Alu/Cu Armoured/unarmoured all core 1.5 sq mm-10 sq mm on wall/provided trench/on ground/on pole with necessary hardware. | Laying of PVC cable Alu/Cu Armoured/unarmoured all core 1.5 sq mm-10 sq mm on wall/provided trench/on ground/on pole with necessary hardware. |
| 16 | Laying of cable Alu/Cu Armoured/unarmoured all core 16 sq mm-35 sq mm on wall/provided trench/on ground/on pole with necessary hardware | Laying of cable Alu/Cu Armoured/unarmoured all core 16 sq mm-35 sq mm on wall/provided trench/on ground/on pole with necessary hardware |
| 17 | Laying of cable Alu/Cu Armoured/unarmoured all core 50 sq mm- 120 sq mm on wall/provided trench/on ground/on pole with necessary hardware | Laying of cable Alu/Cu Armoured/unarmoured all core 50 sq mm- 120 sq mm on wall/provided trench/on ground/on pole with necessary hardware |
| 18 | Laying of cable Alu/Cu Armoured/unarmoured all core 150 sq mm -400 sq mm on wall/provided trench/on ground/on pole with necessary hardware | Laying of cable Alu/Cu Armoured/unarmoured all core 150 sq mm -400 sq mm on wall/provided trench/on ground/on pole with necessary hardware |
| 19 | Dismantling the existing above gound cable of all types & sizes | Dismantling the existing above gound cable of all types & sizes |
| 20 | Dismantling the existing underground cable without damaging it with glands, cables end box including refilling the trench up to ground leveel and making coils complete. | Dismantling the existing underground cable without damaging it with glands, cables end box including refilling the trench up to ground leveel and making coils complete. |
| 21 | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVCPVCarmoured cable 1.1 KV grade complete with ferrules & bushing & accessories and suitable clamps duly erected and connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cableconnected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVCPVCarmoured cable 1.1 KV grade complete with ferrules & bushing & accessories and suitable clamps duly erected and connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cableconnected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable connected to the supply for all cores cable 2.5 Sq.mm to 16 Sq.mm cable |
| 22 | Providing & erecting epoxy straight through joint for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 25 Sq.mm to 50 Sq.mm cable | Providing & erecting epoxy straight through joint for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 25 Sq.mm to 50 Sq.mm cable |
| 23 | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 70 Sq.mm to 185 Sq.mm cable | Providing & erecting epoxy straight through joint outdoor / indoor for L.T. PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 70 Sq.mm to 185 Sq.mm cable |
| 24 | Providing & erecting epoxy straight through joint outdoor / indoor for L.T.PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 240 / 300/400 Sq.mm cable | Providing & erecting epoxy straight through joint outdoor / indoor for L.T.PVC armoured cable 1.1 KV grade complete with ferrules & bushing and accessories and suitable clamps duly erected and connected to the supply for all cores cable 240 / 300/400 Sq.mm cable |
| 25 | Supplying and erecting heavy duty Siemens type brass cable glands for 3 to 4 core 16Sq. Mm. to 3 to 4 core 25 Sq. mm./31/ 2x 35 Sq. mm. PVC armoured cable with brass washers rubber rings complete erected with cable ends & leads connected. | Supplying and erecting heavy duty Siemens type brass cable glands for 3 to 4 core 16Sq. Mm. to 3 to 4 core 25 Sq. mm./31/ 2x 35 Sq. mm. PVC armoured cable with brass washers rubber rings complete erected with cable ends & leads connected. |
| 26 | Supplying and erecting heavy duty Siemens type brass cable glands for 3 to 4 core 50 Sq. Mm. to 3 to 4 core 70 Sq. mm. PVC armoured cable with brass washers rebber rings complete erected with cable ends & leads connected. | Supplying and erecting heavy duty Siemens type brass cable glands for 3 to 4 core 50 Sq. Mm. to 3 to 4 core 70 Sq. mm. PVC armoured cable with brass washers rebber rings complete erected with cable ends & leads connected. |
| 27 | Supplying and erecting heavy duty Siemens type brass cable glands for 3 1/2 x 120 sq. mm. to 3 1/2 x 240 sq. mm PVC armored cable with brass washers rubber rings complete erected with cable ends & leads connected. | Supplying and erecting heavy duty Siemens type brass cable glands for 3 1/2 x 120 sq. mm. to 3 1/2 x 240 sq. mm PVC armored cable with brass washers rubber rings complete erected with cable ends & leads connected. |
| 28 | Supplying and erecting heavy duty Siemens type brass cable glands for to 3 1/2 x 300 sq. mm PVC armored cable with brass washers rubber rings complete erected with cable ends & leads connected. | Supplying and erecting heavy duty Siemens type brass cable glands for to 3 1/2 x 300 sq. mm PVC armored cable with brass washers rubber rings complete erected with cable ends & leads connected. |
| 29 | Supply & erecting crimping type conforming to I.S. suitable for cable up to 550 sq. mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner. | Supply & erecting crimping type conforming to I.S. suitable for cable up to 550 sq. mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner. |
| 30 | Supplying & erecting crimping type aluminum lugs conforming to I.S. suitable for cable up to 35 sq.mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner. | Supplying & erecting crimping type aluminum lugs conforming to I.S. suitable for cable up to 35 sq.mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner. |
| 31 | Supplying & erecting crimping type aluminium lugs conforming to I.S. suitable for cable 50 sq.mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner. | Supplying & erecting crimping type aluminium lugs conforming to I.S. suitable for cable 50 sq.mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner. |
| 32 | Supplying and erecting crimping type aluminium lugs conforming to I.S. suitable for cable 70 sq.mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner.” | Supplying and erecting crimping type aluminium lugs conforming to I.S. suitable for cable 70 sq.mm. Evenly crimped with high pressure tool & connected to switchgear terminals with brass / cadmium plated nut bolts in an approved manner.” |
| 33 | Supplying and erecting pipe type earthing with 40mm. Dia 2.5 mtr.long 'B' grade G.I. Pipe or 20 mm dia. G.I. Rod buried in earth with necessary double G.I. Earth wire no.8 SWG complete erected and connected to nearest switchgears / earth terminal | Supplying and erecting pipe type earthing with 40mm. Dia 2.5 mtr.long 'B' grade G.I. Pipe or 20 mm dia. G.I. Rod buried in earth with necessary double G.I. Earth wire no.8 SWG complete erected and connected to nearest switchgears / earth terminal |
| 34 | Supplying & erecting GI earth wire 14 to 6 SWG complete erected with GI earth wire on wall &/or any other purpose with necessary clamps fixed on wall in an approved manner for earthing or any other purposes. With copper lugs cables socket of 30 amp more ar each end with necessary cadmium plated double nuts & bolts with washers. | Supplying & erecting GI earth wire 14 to 6 SWG complete erected with GI earth wire on wall &/or any other purpose with necessary clamps fixed on wall in an approved manner for earthing or any other purposes. With copper lugs cables socket of 30 amp more ar each end with necessary cadmium plated double nuts & bolts with washers. |
| 35 | Carriage & erection of steel tubular poles 8.50 Mtr. long including foundations & painting. (Poles & junction boxes will be supplied by RCF while remaining material & hardware shall be supplied by the contractor. Erection as per relevant ISI standard | Carriage & erection of steel tubular poles 8.50 Mtr. long including foundations & painting. (Poles & junction boxes will be supplied by RCF while remaining material & hardware shall be supplied by the contractor. Erection as per relevant ISI standard |
| 36 | Same as above but for poles upto 4 to 5 mts. Long. | Same as above but for poles upto 4 to 5 mts. Long. |
| 37 | Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level | Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level |
| 38 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 39 | Erection of departmentally supplied strret light J.B. including connection and hardware. | Erection of departmentally supplied strret light J.B. including connection and hardware. |
| 40 | Erection of departmentally supplied 32 / 63 ICTPN switch 3 phase, 400V/ krone box up to 50 pair including termination of the cable, connection & earthing the same. | Erection of departmentally supplied 32 / 63 ICTPN switch 3 phase, 400V/ krone box up to 50 pair including termination of the cable, connection & earthing the same. |
| 41 | Erection of dept. supplied 100/200/300A ICTPN switch/geyser/motor starter/100-400 pair kbx box on the exiting frame including termination of the cable, connection & earthing the same. | Erection of dept. supplied 100/200/300A ICTPN switch/geyser/motor starter/100-400 pair kbx box on the exiting frame including termination of the cable, connection & earthing the same. |
| 42 | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 core 1.5 SQMM. Make : Polycab/Finolex / KEI | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 core 1.5 SQMM. Make : Polycab/Finolex / KEI |
| 43 | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 core 2.5 SQMM. Make : Polycab/Finolex / KEI | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 3 core 2.5 SQMM. Make : Polycab/Finolex / KEI |
| 44 | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 4 core 1.5 SQMM. Make : Polycab/Finolex / KEI | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 4 core 1.5 SQMM. Make : Polycab/Finolex / KEI |
| 45 | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 4 core 2.5 SQMM. Make : Polycab/Finolex / KEI | Supply of PVC insulated Cu condutor(flexible),Industrial cable PVC sheathed cables ,1100 volts to IS 694 4 core 2.5 SQMM. Make : Polycab/Finolex / KEI |
| 46 | Supply & erecting acrylic sheet of size 3mm thick to be used for covering CRCA sheet bixes etc including cutting,drilling, & oasting or fixing with nut bolts/screw complete | Supply & erecting acrylic sheet of size 3mm thick to be used for covering CRCA sheet bixes etc including cutting,drilling, & oasting or fixing with nut bolts/screw complete |
| 47 | Providing & fixing of FRP street light junction box of IP 66 or above, RYBN connection studs or 6\\"x4\\"x4\\" street light metal pole boxes | Providing & fixing of FRP street light junction box of IP 66 or above, RYBN connection studs or 6\\"x4\\"x4\\" street light metal pole boxes |
| 48 | Upto 4 Core above 16 Sq.mm up to 50 Sq.mm | Upto 4 Core above 16 Sq.mm up to 50 Sq.mm |
| 49 | Upto 4 Core 50 Sq.mm up to 120 Sq.mm | Upto 4 Core 50 Sq.mm up to 120 Sq.mm |
| 50 | Upto 4 Core 120 Sq.mm up to 240 Sq.mm | Upto 4 Core 120 Sq.mm up to 240 Sq.mm |
| 51 | Upto 4 Core 240 Sq.mm up to 400 Sq.mm | Upto 4 Core 240 Sq.mm up to 400 Sq.mm |
| 52 | Supplying & Erecting modular type switch 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type switch 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 53 | Supplying & Erecting modular type bell-push 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type bell-push 6A / 10A ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 54 | Supplying & Erecting modular type 3 pin 6A /10A socket ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type 3 pin 6A /10A socket ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 55 | Supplying & Erecting modular type 3 pin 6A / 16 or 20A Combined Unit ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type 3 pin 6A / 16 or 20A Combined Unit ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 56 | Supplying & Erecting modular type Electronic dimmer / step type regulator, two module ISI mark approved make duly erected on provided plate and box with wiring connections complete. | Supplying & Erecting modular type Electronic dimmer / step type regulator, two module ISI mark approved make duly erected on provided plate and box with wiring connections complete. |
| 57 | Repairs / rewinding of celing fan of 1200 mm sweep | Repairs / rewinding of celing fan of 1200 mm sweep |
| 58 | Replacement of bearings of celing fan with 1200mm sweep | Replacement of bearings of celing fan with 1200mm sweep |
| 59 | Earthing station with 600 mm x 600 mm x 6 mm galvanisediron plate & 50 mm dia. G.I. pipe, 3000mm long GI pipe(Class B or better) earth pit as per IS 3043. The earth pitshall be provided with watering pipe (Class B) with wiremessed funnel, 25x3 GI strip / 8 SWG GI wire up to chamber(wire or strip size as per fault level), disconnecting links with600 x 600 mm (clear) RCC chamber & heavy duty 3mm thickCI chequered plate cover with hinge & stainless steel bolts.Bentonite/ Charcol & Salt shall be provided for earth pits.Excavation, backfilling, removal of excess soil is included inthe scope | Earthing station with 600 mm x 600 mm x 6 mm galvanisediron plate & 50 mm dia. G.I. pipe, 3000mm long GI pipe(Class B or better) earth pit as per IS 3043. The earth pitshall be provided with watering pipe (Class B) with wiremessed funnel, 25x3 GI strip / 8 SWG GI wire up to chamber(wire or strip size as per fault level), disconnecting links with600 x 600 mm (clear) RCC chamber & heavy duty 3mm thickCI chequered plate cover with hinge & stainless steel bolts.Bentonite/ Charcol & Salt shall be provided for earth pits.Excavation, backfilling, removal of excess soil is included inthe scope |
| 60 | Point wiring in concealed manner with PVC conduit. Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FR PVC insulated copper conductor single core cable in concealed manner in heavy duty PVC conduit, with modular switch, modular plate, suitable MS box, ceiling rose and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (from Switch/ taping to light point/ fan point/ exhaust fan point/ call bell point). Pref Make : Polycab / Finolex/KEI | Point wiring in concealed manner with PVC conduit. Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FR PVC insulated copper conductor single core cable in concealed manner in heavy duty PVC conduit, with modular switch, modular plate, suitable MS box, ceiling rose and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. (from Switch/ taping to light point/ fan point/ exhaust fan point/ call bell point). Pref Make : Polycab / Finolex/KEI |
| 61 | Short Points ( from 0-3mtrs : Distence from switch / taping to point ) | Short Points ( from 0-3mtrs : Distence from switch / taping to point ) |
| 62 | Medium Point (From 3 mtrs to 6mtrs : Distence from switch / taping to point ) | Medium Point (From 3 mtrs to 6mtrs : Distence from switch / taping to point ) |
| 63 | Long Points( from 6-10 mtrs : Distence from switch / taping to point ) | Long Points( from 6-10 mtrs : Distence from switch / taping to point ) |
| 64 | 20mm | 20mm |
| 65 | 25mm | 25mm |
| 66 | 32mm | 32mm |
| 67 | 40mm | 40mm |
| 68 | 50mm | 50mm |
| 69 | 2 x 1.5 sq. mm | 2 x 1.5 sq. mm |
| 70 | 3 x 1.5 sq. mm | 3 x 1.5 sq. mm |
| 71 | 3 x 2.5 sq. mm | 3 x 2.5 sq. mm |
| 72 | 3 x 6 sq. mm | 3 x 6 sq. mm |
| 73 | 4 x 6 sq. mm | 4 x 6 sq. mm |
| 74 | Short Points ( from 0-3mtrs) (2C / 3C X 1.5 Sqmm ) | Short Points ( from 0-3mtrs) (2C / 3C X 1.5 Sqmm ) |
| 75 | Medium point (From 3 mtrs to 6mtrs) (2C / 3C X 1.5 Sqmm ) | Medium point (From 3 mtrs to 6mtrs) (2C / 3C X 1.5 Sqmm ) |
| 76 | Long Points( from 6-10 mtrs) (2C / 3C X 1.5 Sqmm ) | Long Points( from 6-10 mtrs) (2C / 3C X 1.5 Sqmm ) |
| 77 | 15 /16A power point using 3 C X 2.5 sqmm wires of mentioned make. (6-12 meter) | 15 /16A power point using 3 C X 2.5 sqmm wires of mentioned make. (6-12 meter) |
| 78 | 1 or 2 Module | 1 or 2 Module |
| 79 | 4 Module | 4 Module |
| 80 | 6 Module | 6 Module |
| 81 | 8 Module | 8 Module |
| 82 | 12 Module /18 Module | 12 Module /18 Module |
| 83 | 8 Way SPN DB | 8 Way SPN DB |
| 84 | 12 Way SPN DB | 12 Way SPN DB |
| 85 | 16 Way SPN DB (4 + 12Way) | 16 Way SPN DB (4 + 12Way) |
| 86 | TPN DB (8 + 12Way) | TPN DB (8 + 12Way) |
| 87 | Fixing of 2'X2' LED / Mirror optic fiting with independent support. Removal of existing 2' X 2' 4X18W T/L/ LED fitting from falls celing with disconnection & determination of connections. Supply and fixing of 4 nos of \\"J\\" screw type hooks / angle fasteners on the celing & GI wire for fixing of fittings. Installation of removed above said fittings on newly installed \\"J\\" hooks / angle fastener with GI wire up to falls celing & termination to existing connection. | Fixing of 2'X2' LED / Mirror optic fiting with independent support. Removal of existing 2' X 2' 4X18W T/L/ LED fitting from falls celing with disconnection & determination of connections. Supply and fixing of 4 nos of \\"J\\" screw type hooks / angle fasteners on the celing & GI wire for fixing of fittings. Installation of removed above said fittings on newly installed \\"J\\" hooks / angle fastener with GI wire up to falls celing & termination to existing connection. |
| 88 | Normalising Road after cable laying: Nominal mix of 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size. | Normalising Road after cable laying: Nominal mix of 1:2:4 (1cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size. |
| 89 | Supplying and fixing of 15A Combination of Anchor/ L&T / Legrand/ Schneider etc. | Supplying and fixing of 15A Combination of Anchor/ L&T / Legrand/ Schneider etc. |
| 90 | Supply and Laying of PVC Trunking-25mm size | Supply and Laying of PVC Trunking-25mm size |
| 91 | Supply and Laying of PVC Trunking-50mm size | Supply and Laying of PVC Trunking-50mm size |
| 92 | Supply and erection of socket - step type electronic regulator | Supply and erection of socket - step type electronic regulator |
| 93 | Supply and erection of 8 - 9W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. | Supply and erection of 8 - 9W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. |
| 94 | Supply and erection of 12 - 15W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro | Supply and erection of 12 - 15W LED Bulb of make Havells/Crompton/ Surya/Polycab/Philips/Wipro |
| 95 | Supply and erection of LED tube light batten of 2ft of make Havells/Crompton/ Surya/Polycab/Philips/Wipro | Supply and erection of LED tube light batten of 2ft of make Havells/Crompton/ Surya/Polycab/Philips/Wipro |
| 96 | Supply and erection of LED tube light batten of 4ft of make Havells/Crompton/ Surya/Polycab/Philips/Wipro | Supply and erection of LED tube light batten of 4ft of make Havells/Crompton/ Surya/Polycab/Philips/Wipro |
| 97 | Supply and erection of LED square fitting of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. (10-15 W) (75 mm X75 mm) | Supply and erection of LED square fitting of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. (10-15 W) (75 mm X75 mm) |
| 98 | Making trench in soft soil with a width up to 2 ft, depth of 4feet. Back filling shall also be included. | Making trench in soft soil with a width up to 2 ft, depth of 4feet. Back filling shall also be included. |
| 99 | Making trench in hard soil with a width up to 2 ft, depth of 4feet | Making trench in hard soil with a width up to 2 ft, depth of 4feet |
| 100 | Supply and erection of 100W LED flood light of colour white/yellow/Blue or any other colour : make Havells/Crompton/ Surya/Polycab/Philips/Wipro etc. Flood light shall be with lens or with suitable replector. | Supply and erection of 100W LED flood light of colour white/yellow/Blue or any other colour : make Havells/Crompton/ Surya/Polycab/Philips/Wipro etc. Flood light shall be with lens or with suitable replector. |
| 101 | Supply and erection of 50W LED street lights with peanut lences of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. Fitting shall be of pipe mounted. | Supply and erection of 50W LED street lights with peanut lences of make Havells/Crompton/ Surya/Polycab/Philips/Wipro. Fitting shall be of pipe mounted. |
| 102 | Laying of bricks on cable in lenth wise. | Laying of bricks on cable in lenth wise. |
| 103 | Laying of full hume pipe of size six inche | Laying of full hume pipe of size six inche |
| 104 | Supply and erection of 20W LED street lights with peanut lences of makeHavells/Crompton/ Surya/ Polycab/Philips / Wipro. | Supply and erection of 20W LED street lights with peanut lences of makeHavells/Crompton/ Surya/ Polycab/Philips / Wipro. |
| 105 | Supply and erection of 16A - 25 A, 30mA RCBO, 2 pole of make legrand/ L&T/Havells/Hager. | Supply and erection of 16A - 25 A, 30mA RCBO, 2 pole of make legrand/ L&T/Havells/Hager. |
| 106 | Supply and erection of 32/40A, 30mA RCBO, 2pole of make legrand/ L&T/Havells/Hager | Supply and erection of 32/40A, 30mA RCBO, 2pole of make legrand/ L&T/Havells/Hager |
| 107 | Supply and errection of celing rose / square box/all types of holder | Supply and errection of celing rose / square box/all types of holder |
| 108 | Wall mounting fan - 400mm sweep. Make : Bajaj / Almonard / Crompton Greaves / Havells / Orient | Wall mounting fan - 400mm sweep. Make : Bajaj / Almonard / Crompton Greaves / Havells / Orient |
| 109 | Pedestrial Fan with a sweep of 400 MM. Make : Bajaj / Almonard / Crompton Greaves / Havells / Orient | Pedestrial Fan with a sweep of 400 MM. Make : Bajaj / Almonard / Crompton Greaves / Havells / Orient |
| 110 | Supply and laying of 3C X 2.5 sqmm armoured XLPE cable of Pref make Polycab / Finolex /KEI | Supply and laying of 3C X 2.5 sqmm armoured XLPE cable of Pref make Polycab / Finolex /KEI |
| 111 | Supply and laying of 3C X 6 sqmm armoured XLPE cable of Pref make Polycab / Finolex/KEI | Supply and laying of 3C X 6 sqmm armoured XLPE cable of Pref make Polycab / Finolex/KEI |
| 112 | Supply, installation of Metalic industrial AC Boc with suitable 20A plug with Metal clad plug top without MCB. Make : Anchor / Havells / Reyrole / Havells / Poly cab / legrand. | Supply, installation of Metalic industrial AC Boc with suitable 20A plug with Metal clad plug top without MCB. Make : Anchor / Havells / Reyrole / Havells / Poly cab / legrand. |
| 113 | Supply of suitable welding machine with skilled operator or welder .( for 8 Hr) | Supply of suitable welding machine with skilled operator or welder .( for 8 Hr) |
| 114 | Supply of suitable MS angles and fabrication of the same | Supply of suitable MS angles and fabrication of the same |
| 115 | Supply of suitable MS I - channel and fabrication of the same | Supply of suitable MS I - channel and fabrication of the same |
| 116 | Supply and laying of GI Earthing pattie with suitable clamps. Width : 25mm to 100 mm& thickness : 3 mm - 10mm | Supply and laying of GI Earthing pattie with suitable clamps. Width : 25mm to 100 mm& thickness : 3 mm - 10mm |
| 117 | Supply on hiring basis, installation of 100 to 150 LED fittings with required wires / cables | Supply on hiring basis, installation of 100 to 150 LED fittings with required wires / cables |
| 118 | Supply, installation and commissioning of 12 to 15 W LED circular downlighter of suitable size to existing cut-out make : Havells / CG/Polycab/Fiem / Wipro / Philiphs | Supply, installation and commissioning of 12 to 15 W LED circular downlighter of suitable size to existing cut-out make : Havells / CG/Polycab/Fiem / Wipro / Philiphs |
| 119 | Supply, installation and commissioning of 12 to 15 W LED circular downlighter / surface mount of make : Havells / CG/Polycab/Fiem / Wipro / Philiphs | Supply, installation and commissioning of 12 to 15 W LED circular downlighter / surface mount of make : Havells / CG/Polycab/Fiem / Wipro / Philiphs |
| 120 | Supply of LED square fitting of approximate size 300 mm X 300 X300 mm square downlighter / surface mount LED fitting of make Havwlls / CG/Polycab/Fiem / Wipro / Philiphs. Wattage : Up to 15 - 22 W | Supply of LED square fitting of approximate size 300 mm X 300 X300 mm square downlighter / surface mount LED fitting of make Havwlls / CG/Polycab/Fiem / Wipro / Philiphs. Wattage : Up to 15 - 22 W |
| 121 | Supply of LED square fitting of approximate size 600 mm X 600 mm square downlighter / surface mount LED fitting of make Havwlls / CG/Polycab/Fiem / Wipro / Philiphs. Wattage : Up to 15 - 22 W | Supply of LED square fitting of approximate size 600 mm X 600 mm square downlighter / surface mount LED fitting of make Havwlls / CG/Polycab/Fiem / Wipro / Philiphs. Wattage : Up to 15 - 22 W |
| 122 | Replacement of existing 5 / 6 A switch / Bell push piano switch with new Anchor / Legrand/ L & T make 5 / 6 A switch. Cost shall include replacement of old switch also | Replacement of existing 5 / 6 A switch / Bell push piano switch with new Anchor / Legrand/ L & T make 5 / 6 A switch. Cost shall include replacement of old switch also |
| 123 | Replacement of existing 5 / 6A plug with new Anchor / Legrand/ L & T make 5A Plug. Cost shall include replacement of old plug also | Replacement of existing 5 / 6A plug with new Anchor / Legrand/ L & T make 5A Plug. Cost shall include replacement of old plug also |
| 124 | Supply. Installation and commissioning of 100A 4 pole MCB isolator of Make L & T, Legrand/Anchor/ Hager | Supply. Installation and commissioning of 100A 4 pole MCB isolator of Make L & T, Legrand/Anchor/ Hager |
| 125 | Supply. Installation and commissioning of 63A, 3 pole isolator of Make L & T, Legrand/Anchor/ Hager | Supply. Installation and commissioning of 63A, 3 pole isolator of Make L & T, Legrand/Anchor/ Hager |
| 126 | Supply, installation and commissioning of Switch disconnector fuse (SDF) - 125 A with MS enclosure. Same shall be supplied with suitable fuses. Make : L & T, Kew, Havels . C &S | Supply, installation and commissioning of Switch disconnector fuse (SDF) - 125 A with MS enclosure. Same shall be supplied with suitable fuses. Make : L & T, Kew, Havels . C &S |
| 127 | Supply, installation and commissioning of Switch disconnector fuse (SDF) - 63 A with MS enclosure. Same shall be supplied with suitable fuses. Make : L & T,Havels | Supply, installation and commissioning of Switch disconnector fuse (SDF) - 63 A with MS enclosure. Same shall be supplied with suitable fuses. Make : L & T,Havels |
| 128 | Supply, installation and commissioning of Switch disconnector fuse (SDF) - 250A / 260 Awith MS enclosure. Same shall be supplied with suitable fuses. Make : L & T, Kew, Havels . C &S | Supply, installation and commissioning of Switch disconnector fuse (SDF) - 250A / 260 Awith MS enclosure. Same shall be supplied with suitable fuses. Make : L & T, Kew, Havels . C &S |
| 129 | Supply, installation and commissioning of 16 /20 A modular switch of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 16 /20 A modular switch of make Hifi / L & T/Havells / Roma |
| 130 | Supply, installation and commissioning of 16 /20 A modular socket / 16-5A combination modular socket of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 16 /20 A modular socket / 16-5A combination modular socket of make Hifi / L & T/Havells / Roma |
| 131 | Supply, installation and commissioning of 25 A modular switch of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 25 A modular switch of make Hifi / L & T/Havells / Roma |
| 132 | Supply, installation and commissioning of 25 A modular socket of make Hifi / L & T/Havells / Roma | Supply, installation and commissioning of 25 A modular socket of make Hifi / L & T/Havells / Roma |
| 133 | Industrial plug top for AC Box of rating 16A suitable for existing AC Box | Industrial plug top for AC Box of rating 16A suitable for existing AC Box |
| 134 | Supply, installation and commission of L&T make SDF of 400 A | Supply, installation and commission of L&T make SDF of 400 A |
| 135 | Supply, installation and commissioning of L&T HN fuses-63 A, Size 000 | Supply, installation and commissioning of L&T HN fuses-63 A, Size 000 |
| 136 | Supply, installation and commissioning of L&T HN fuses-80 A, Size 000 | Supply, installation and commissioning of L&T HN fuses-80 A, Size 000 |
| 137 | Supply, installation and commissioning of L&T HN fuses-100 A, Size 000 | Supply, installation and commissioning of L&T HN fuses-100 A, Size 000 |
| 138 | Supply, installation and commissioning of L&T HN fuses-125 A, Size 000 | Supply, installation and commissioning of L&T HN fuses-125 A, Size 000 |
| 139 | Supply, installation and commissioning of L&T HN fuses-160 A, Size 00 | Supply, installation and commissioning of L&T HN fuses-160 A, Size 00 |
| 140 | Supply, installation and commissioning of L&T HN fuses-125 A, Size 0 | Supply, installation and commissioning of L&T HN fuses-125 A, Size 0 |
| 141 | Supply, installation and commissioning of L&T HN fuses-160 A, Size 0 | Supply, installation and commissioning of L&T HN fuses-160 A, Size 0 |
| 142 | Supply, installation and commissioning of L&T HN fuses-250 A, Size I | Supply, installation and commissioning of L&T HN fuses-250 A, Size I |
| 143 | Supply, installation and commissioning of L&T HN fuses-315 A, Size 1 | Supply, installation and commissioning of L&T HN fuses-315 A, Size 1 |
| 144 | Supply, installation and commissioning of L&T HN fuses-400 A, Size II | Supply, installation and commissioning of L&T HN fuses-400 A, Size II |
| 145 | Supply, installation and commissioning of L&T make cylindrical type fuse link HF63A. | Supply, installation and commissioning of L&T make cylindrical type fuse link HF63A. |
| 146 | Supply & erecting mains in provided concealed / open conduit or equivalent with 3C X 4 sqmm F R standard/solid copper PVC Insulated wire of POLYCAB / Finolex | Supply & erecting mains in provided concealed / open conduit or equivalent with 3C X 4 sqmm F R standard/solid copper PVC Insulated wire of POLYCAB / Finolex |
| 147 | Supply, installation and commissioning of 40 - 63 A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supply, installation and commissioning of 40 - 63 A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 148 | Supply, installation and commissioning of up to 32A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supply, installation and commissioning of up to 32A, double pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 149 | Supply, installation and commissioning of 63A, three pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager, C&S Electric | Supply, installation and commissioning of 63A, three pole MCB of B curve. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager, C&S Electric |
| 150 | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 16 - 32-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 16 - 32-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 151 | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 40 amp to 63-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager | Supplying, erercting & marking miniature circuit breaker conforming to IS:8828 of 1996) single pole 40 amp to 63-amp B series (lighting) with required wiring connections and lugs etc. in provided distribution board. Make :- Legrand, Havells, Finolex, Siemens, Schneider, ABB, Orient Electric, Eaton, Hager |
| 152 | Supply and fabrication of class C GI pipe of different OD (Suitable to base fittings) to streetlight poles, garden light poles etc. Scope shall also include painting of 1 coat fprime with 2 coat of silver colour, | Supply and fabrication of class C GI pipe of different OD (Suitable to base fittings) to streetlight poles, garden light poles etc. Scope shall also include painting of 1 coat fprime with 2 coat of silver colour, |
| 153 | Supply, installation and commissioning LED garden light (post top lantern) of 25W, suitable for 75 mm OD pipe, clear diffuser Housing : Powder coated Aluminum die cast and spun Aluminum. Makes : Havells, Fiem, Polycab. Picture is attached for reference, | Supply, installation and commissioning LED garden light (post top lantern) of 25W, suitable for 75 mm OD pipe, clear diffuser Housing : Powder coated Aluminum die cast and spun Aluminum. Makes : Havells, Fiem, Polycab. Picture is attached for reference, |
| 154 | Supply and fixing of suitable fan- down road.( Length may vary up to 3 ft ). | Supply and fixing of suitable fan- down road.( Length may vary up to 3 ft ). |
| 155 | Supply, installation and commissiong of GI busbar ( Hot dip) for earthing connection. (SIZE : 34 mm (L) x 50 mm (W) X6 mm ) Busbar shall have six no holes and be provided with suitable stainless steel nut bolts for taping connections. | Supply, installation and commissiong of GI busbar ( Hot dip) for earthing connection. (SIZE : 34 mm (L) x 50 mm (W) X6 mm ) Busbar shall have six no holes and be provided with suitable stainless steel nut bolts for taping connections. |
| 156 | Constructing 230 mm thick Brick Masonry chamber 600(length)x600(width)x4500 (depth) around the electrode as per approved drawing. | Constructing 230 mm thick Brick Masonry chamber 600(length)x600(width)x4500 (depth) around the electrode as per approved drawing. |
| 157 | Supply and Installation of CI hinged cover (Minimum 5 MM Thickness) for Earth pits of clear opening 450 mm x 450 mm, as per scope of work | Supply and Installation of CI hinged cover (Minimum 5 MM Thickness) for Earth pits of clear opening 450 mm x 450 mm, as per scope of work |
| 158 | Letter writing on earth pits cover as per approved format for identifications as Instructed by RCF Engineer-In-Charge. (Resistance value, test date and pit identification no - as provided by RCF. ) | Letter writing on earth pits cover as per approved format for identifications as Instructed by RCF Engineer-In-Charge. (Resistance value, test date and pit identification no - as provided by RCF. ) |
| 159 | Preperation of Layout of cable laying (Up to 500 meter) / substations / etc in autocad or equivalent software and submitting the same as per instruction by site in charge, Prepred lay-out shall clearly indicate buildings and roads as applicable. Drawing shall be submitted in A0 or A1 sheet in triplicate. | Preperation of Layout of cable laying (Up to 500 meter) / substations / etc in autocad or equivalent software and submitting the same as per instruction by site in charge, Prepred lay-out shall clearly indicate buildings and roads as applicable. Drawing shall be submitted in A0 or A1 sheet in triplicate. |
| 160 | Supply instalation and commissioning of Modular SP MCB of rating up to 25 A. | Supply instalation and commissioning of Modular SP MCB of rating up to 25 A. |
| 161 | 20 HP motor shifting, raising, or lowering utilizing a cahiin pulley block, D shackle, sling rope etc. The bidder must provide a minimum of four skilled riggers along with the necessary lifting equipment, such as chain pulley block, D shackle, and sling ropes. | 20 HP motor shifting, raising, or lowering utilizing a cahiin pulley block, D shackle, sling rope etc. The bidder must provide a minimum of four skilled riggers along with the necessary lifting equipment, such as chain pulley block, D shackle, and sling ropes. |
| 162 | Supply and installation of good quality finished 3 mm SS Plate with Raceway junction box frame (Plate size upto 13.5 × 13.5 inches, Frame size upto 93 × 39 cm) with required hardware for concealed metal race way junction boxes for proper support with floor and face to face matching with floor | Supply and installation of good quality finished 3 mm SS Plate with Raceway junction box frame (Plate size upto 13.5 × 13.5 inches, Frame size upto 93 × 39 cm) with required hardware for concealed metal race way junction boxes for proper support with floor and face to face matching with floor |
| 163 | Supply, carriage, installation and commissioning of 28W, 1200 mm, double ball bearing, three blade BLDC ceiling fan. Rated air delivery shall be 280 MM or better. Speed control – 5 speed control with remote (shall be supplied with the fan) / with step type regulator. Colour shall be finalized by site-in-charge as per requirement. Type test certificate from NABL approved lab. | Supply, carriage, installation and commissioning of 28W, 1200 mm, double ball bearing, three blade BLDC ceiling fan. Rated air delivery shall be 280 MM or better. Speed control – 5 speed control with remote (shall be supplied with the fan) / with step type regulator. Colour shall be finalized by site-in-charge as per requirement. Type test certificate from NABL approved lab. |
| 164 | Van mounted articulator for street light job/ Hydra for lifting 1.5 Ton on hiring for 8 Hr. | Van mounted articulator for street light job/ Hydra for lifting 1.5 Ton on hiring for 8 Hr. |
| 165 | Loading or unloading of three-phase induction motors ranging from 10 HP to less than 30 HP (No chain block/hoist is available in the pump house or warehouse). Scope includes the safe loading and unloading of induction motors from the foundations (pump house) to the designated tranPriyadarshini & Admin. Bldg vehicle (and vice versa) by opening the coupling and removing the connection and termination of the cable. While unloading, the scope shall also include installing the motor on the designated foundation. Equipment: The contractor shall deploy appropriate, load-tested lifting gear, including but not limited to tripods, chain blocks, manual/electric hoists, or mobile cranes, depending on site constraints and motor weight. The contractor shall exercise extreme caution to prevent any damage to existing site infrastructure, including nearby pipelines, cable trays, instrument cables, and structural members. Motors must be handled to avoid impact on the cooling fan covers, terminal boxes, and shaft ends. | Loading or unloading of three-phase induction motors ranging from 10 HP to less than 30 HP (No chain block/hoist is available in the pump house or warehouse). Scope includes the safe loading and unloading of induction motors from the foundations (pump house) to the designated tranPriyadarshini & Admin. Bldg vehicle (and vice versa) by opening the coupling and removing the connection and termination of the cable. While unloading, the scope shall also include installing the motor on the designated foundation. Equipment: The contractor shall deploy appropriate, load-tested lifting gear, including but not limited to tripods, chain blocks, manual/electric hoists, or mobile cranes, depending on site constraints and motor weight. The contractor shall exercise extreme caution to prevent any damage to existing site infrastructure, including nearby pipelines, cable trays, instrument cables, and structural members. Motors must be handled to avoid impact on the cooling fan covers, terminal boxes, and shaft ends. |
| 166 | Loading or unloading of three-phase induction motors ranging from 30 HP to 50 HP (No chain block/hoist is available in the pump house or warehouse). Scope includes the safe loading and unloading of induction motors from the foundations (pump house) to the designated tranPriyadarshini & Admin. Bldg vehicle (and vice versa) by opening the coupling and removing the connection and termination of the cable. While unloading, the scope shall also include installing the motor on the designated foundation. Equipment: The contractor shall deploy appropriate, load-tested lifting gear, including but not limited to tripods, chain blocks, manual/electric hoists, or mobile cranes, depending on site constraints and motor weight. The contractor shall exercise extreme caution to prevent any damage to existing site infrastructure, including nearby pipelines, cable trays, instrument cables, and structural members. Motors must be handled to avoid impact on the cooling fan covers, terminal boxes, and shaft ends. | Loading or unloading of three-phase induction motors ranging from 30 HP to 50 HP (No chain block/hoist is available in the pump house or warehouse). Scope includes the safe loading and unloading of induction motors from the foundations (pump house) to the designated tranPriyadarshini & Admin. Bldg vehicle (and vice versa) by opening the coupling and removing the connection and termination of the cable. While unloading, the scope shall also include installing the motor on the designated foundation. Equipment: The contractor shall deploy appropriate, load-tested lifting gear, including but not limited to tripods, chain blocks, manual/electric hoists, or mobile cranes, depending on site constraints and motor weight. The contractor shall exercise extreme caution to prevent any damage to existing site infrastructure, including nearby pipelines, cable trays, instrument cables, and structural members. Motors must be handled to avoid impact on the cooling fan covers, terminal boxes, and shaft ends. |
| 167 | Carrying the departmentally supplied industrial extension board with RCBO/ to the designated place with in the Priyadarshini & Admin. Bldg, checking, repairing, testing, and energising by connecting the incoming supply by a licensed electrician. Scope shall also include de-energising the above-mentioned board by disconnecting the supply and carrying the board back to the designated place in the Priyadarshini & Admin. Bldgs club. Minor consumable materials need to be arranged by the contractor. It may be noted that tripping of the RCBO against leakage current must be ensured. | Carrying the departmentally supplied industrial extension board with RCBO/ to the designated place with in the Priyadarshini & Admin. Bldg, checking, repairing, testing, and energising by connecting the incoming supply by a licensed electrician. Scope shall also include de-energising the above-mentioned board by disconnecting the supply and carrying the board back to the designated place in the Priyadarshini & Admin. Bldgs club. Minor consumable materials need to be arranged by the contractor. It may be noted that tripping of the RCBO against leakage current must be ensured. |
| 168 | Preventive maintenance of the a three-phase induction motors up to 10 HP coupled with a centrifugal pump assembly, including all labour, specialised tools, and consumables; the scope shall include measurement of insulation resistance (IR) using a 500V/1000V Megger; checking and tightening of all terminal connections; inspection of the cooling fan; cleaning of motor fins for heat dissipation; regressing of the motor; inspection of foundation and coupling bolts; replacement of the foundation bolts if required; and inspection of the alignment with the pump. Post-maintenance recording of no-load and load current in normal operating conditions shall also be covered in the scope. A detailed service report shall be prepared and submitted. | Preventive maintenance of the a three-phase induction motors up to 10 HP coupled with a centrifugal pump assembly, including all labour, specialised tools, and consumables; the scope shall include measurement of insulation resistance (IR) using a 500V/1000V Megger; checking and tightening of all terminal connections; inspection of the cooling fan; cleaning of motor fins for heat dissipation; regressing of the motor; inspection of foundation and coupling bolts; replacement of the foundation bolts if required; and inspection of the alignment with the pump. Post-maintenance recording of no-load and load current in normal operating conditions shall also be covered in the scope. A detailed service report shall be prepared and submitted. |
| 169 | Preventive maintenance of the a three-phase induction motors (15 HP – 50 HP ) coupled with a centrifugal pump assembly, including all labour, specialised tools, and consumables; the scope shall include measurement of insulation resistance (IR) using a 500V/1000V Megger; checking and tightening of all terminal connections; inspection of the cooling fan; cleaning of motor fins for heat dissipation; regressing of the motor; inspection of foundation and coupling bolts; replacement of the foundation bolts if required; and inspection of the alignment with the pump. Post-maintenance recording of no-load and load current in normal operating conditions shall also be covered in the scope. A detailed service report shall be prepared and submitted. | Preventive maintenance of the a three-phase induction motors (15 HP – 50 HP ) coupled with a centrifugal pump assembly, including all labour, specialised tools, and consumables; the scope shall include measurement of insulation resistance (IR) using a 500V/1000V Megger; checking and tightening of all terminal connections; inspection of the cooling fan; cleaning of motor fins for heat dissipation; regressing of the motor; inspection of foundation and coupling bolts; replacement of the foundation bolts if required; and inspection of the alignment with the pump. Post-maintenance recording of no-load and load current in normal operating conditions shall also be covered in the scope. A detailed service report shall be prepared and submitted. |
| 170 | Attending to no-light complaints, electrical shock reports, earth leakage complaints, and general circuit failures on a standalone basis. The scope includes fault identification, isolation of defective segments, and restoration of power. Fault identification: Systematic tracing of circuits to identify short circuits, open circuits, earth leakage (causing shocks), or neutral failures using calibrated multimeters/insulation testers. Identified faults shall be rectified by re-termination of loose connections at DBs, switches, or fixtures; cleaning of carbonised contacts; and bypassing or replacing minor defective wiring segments. Provision of all minor materials required for the fix, including but not limited to: PVC insulation tape, wire ferrules, rawl plugs, screws, cable ties, and short lengths of connecting wire. | Attending to no-light complaints, electrical shock reports, earth leakage complaints, and general circuit failures on a standalone basis. The scope includes fault identification, isolation of defective segments, and restoration of power. Fault identification: Systematic tracing of circuits to identify short circuits, open circuits, earth leakage (causing shocks), or neutral failures using calibrated multimeters/insulation testers. Identified faults shall be rectified by re-termination of loose connections at DBs, switches, or fixtures; cleaning of carbonised contacts; and bypassing or replacing minor defective wiring segments. Provision of all minor materials required for the fix, including but not limited to: PVC insulation tape, wire ferrules, rawl plugs, screws, cable ties, and short lengths of connecting wire. |
| 171 | supply laying and termination of single core AL unarmoured earthing cable upto 16 sq mm | supply laying and termination of single core AL unarmoured earthing cable upto 16 sq mm |
| 172 | supply laying and termination of single core AL unarmoured earthing cable upto 35 sq mm | supply laying and termination of single core AL unarmoured earthing cable upto 35 sq mm |
| 173 | supply laying and termination ofsingle core AL unarmoured earthing cable upto 70 sq mm | supply laying and termination ofsingle core AL unarmoured earthing cable upto 70 sq mm |
| 174 | Supply, fabrication, and installation of GI perforated-type cable tray of size Size 50 mm width X 50 mm depth X 2500 mm with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. | Supply, fabrication, and installation of GI perforated-type cable tray of size Size 50 mm width X 50 mm depth X 2500 mm with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. |
| 175 | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 150 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 150 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. |
| 176 | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 300 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. | Supply, fabrication, and installation of GI perforated-type cable tray of size Size: 300 mm width x 50 mm depth x 2500 mm length with 2.5 mm thickness. The tray supplied shall be accessories and hardware like nut bolts, washers, fixing clamps, bends, joints, etc. |
| 177 | Connection of 2 or 3 core cables to the provided RCBO extension board / arranging temporary supply with departmentally provided components / installing or removing departmentally supplied HF or HN fuses / checking tightness of termination / busbar / insulation / or similar miscellaneous electrical jobs. An appropriate fuse puller arrangement shall be in the scope of the contractor. (The job has to be carried out by licensed technicians only; a helper also must be deployed to support the licensed technician. If instructed, the contractor must ensure the availability of the required manpower as directed.) :Standalone item | Connection of 2 or 3 core cables to the provided RCBO extension board / arranging temporary supply with departmentally provided components / installing or removing departmentally supplied HF or HN fuses / checking tightness of termination / busbar / insulation / or similar miscellaneous electrical jobs. An appropriate fuse puller arrangement shall be in the scope of the contractor. (The job has to be carried out by licensed technicians only; a helper also must be deployed to support the licensed technician. If instructed, the contractor must ensure the availability of the required manpower as directed.) :Standalone item |
| 178 | Installation, testing and commissioning of supplied MS meter box of 1200 mm x 850 mm x 250 mm, approximate weight 85 to 100 kg. Scope shall also include termination of 4/3.5 C x 35/70 sq mm Al cable, termination of 6 no service mains, installing departmentally supplied 2 model RCBos, labelling of all MCBs, energy meters, etc. PVC conduits through which service mains are laid shall be terminated with suitable glands. All redundant openings shall be closed. | Installation, testing and commissioning of supplied MS meter box of 1200 mm x 850 mm x 250 mm, approximate weight 85 to 100 kg. Scope shall also include termination of 4/3.5 C x 35/70 sq mm Al cable, termination of 6 no service mains, installing departmentally supplied 2 model RCBos, labelling of all MCBs, energy meters, etc. PVC conduits through which service mains are laid shall be terminated with suitable glands. All redundant openings shall be closed. |
| 179 | supply installation of 1200 mm ceiling fan 3 blades SET suitable for usha, bajaj orient | supply installation of 1200 mm ceiling fan 3 blades SET suitable for usha, bajaj orient |
| 180 | supply installation of 1200 mm ceiling fan 2 caps SET suitable for usha, bajaj orient | supply installation of 1200 mm ceiling fan 2 caps SET suitable for usha, bajaj orient |
| 181 | supply installation of 1 watt coloured LED night lamp | supply installation of 1 watt coloured LED night lamp |
| 182 | Preventive Maintenance of the drum assembly, rope assembly adjustment and their alignment, Greasing/oiling of motor, gearbox, drum, rope, chain, and proper alignment of head frame and Lantern ring if it found tilt etc. to make ease in operation of 12.5 M High mast Tower. (Supply od consumables like grease /winch gear oil/wire rope lubricant/cotter pins & fastners/contact cleaner/Gland packing/sealants/Micro fiber cloths/scrubbers, Cotton waste /rags shall be the sole responsibility of the contractor.) This activity is standalone, and no minimum quantity is guarenteed | Preventive Maintenance of the drum assembly, rope assembly adjustment and their alignment, Greasing/oiling of motor, gearbox, drum, rope, chain, and proper alignment of head frame and Lantern ring if it found tilt etc. to make ease in operation of 12.5 M High mast Tower. (Supply od consumables like grease /winch gear oil/wire rope lubricant/cotter pins & fastners/contact cleaner/Gland packing/sealants/Micro fiber cloths/scrubbers, Cotton waste /rags shall be the sole responsibility of the contractor.) This activity is standalone, and no minimum quantity is guarenteed |
| 183 | Replacement of lighting fixtures of the 12.5-M high mast: Scope shall include carrying the departmentally supplied light fixture from the departmental office to the site within the Priyadarshini & Admin. Bldg and operating the high mast motor and lowering the lantern ring assembly safely to replace the fitting. Old fittings shall be carried back to the department. This activity is standalone, and no minimum quantity is guarenteed | Replacement of lighting fixtures of the 12.5-M high mast: Scope shall include carrying the departmentally supplied light fixture from the departmental office to the site within the Priyadarshini & Admin. Bldg and operating the high mast motor and lowering the lantern ring assembly safely to replace the fitting. Old fittings shall be carried back to the department. This activity is standalone, and no minimum quantity is guarenteed |
| 184 | Replacement of lighting fixtures of the street light poles up to a height of 7.5 metres. Scope shall include carrying the departmentally supplied borrage light fixture / street light from the departmental office or store within the Priyadarshini & Admin. Bldg area to the site within the Priyadarshini & Admin. Bldg and safely replace the fitting with a departmentally supplied wheel ladder / articulator. TranPriyadarshini & Admin. Bldgation of the wheel ladder shall be the responsibility of the bidder. Old fittings shall be carried back to the department. | Replacement of lighting fixtures of the street light poles up to a height of 7.5 metres. Scope shall include carrying the departmentally supplied borrage light fixture / street light from the departmental office or store within the Priyadarshini & Admin. Bldg area to the site within the Priyadarshini & Admin. Bldg and safely replace the fitting with a departmentally supplied wheel ladder / articulator. TranPriyadarshini & Admin. Bldgation of the wheel ladder shall be the responsibility of the bidder. Old fittings shall be carried back to the department. |
| 185 | Preventive maintenance / inspection / fault finding of a street light pole under a substation or timer box: The scope includes inspecting and preparing a report on whether street light poles are functional, identifying, isolating and rectifying if there is any fault. Scope shall include checking of pole junction boxes, cables, terminations or light fixtures with appropriate manpower/tools, etc. on an incident/event basis. | Preventive maintenance / inspection / fault finding of a street light pole under a substation or timer box: The scope includes inspecting and preparing a report on whether street light poles are functional, identifying, isolating and rectifying if there is any fault. Scope shall include checking of pole junction boxes, cables, terminations or light fixtures with appropriate manpower/tools, etc. on an incident/event basis. |
| 186 | Maintenance of the street light pole: The scope includes maintenance of the built-in junction box by replacing the stud connector, replacement of the gasket to improve IP, replacement of the damaged flexible cable (supplied by the department), cleaning of fixtures, and checking/testing of the pole's working condition with appropriate manpower/tools, etc., on a daily basis. The articulator/ladder will be arranged by the department. | Maintenance of the street light pole: The scope includes maintenance of the built-in junction box by replacing the stud connector, replacement of the gasket to improve IP, replacement of the damaged flexible cable (supplied by the department), cleaning of fixtures, and checking/testing of the pole's working condition with appropriate manpower/tools, etc., on a daily basis. The articulator/ladder will be arranged by the department. |
| 187 | De-coiling / coiling of the cables upto 4C X 35 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. | De-coiling / coiling of the cables upto 4C X 35 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. |
| 188 | De-coiling / coiling of the cables 4CX50 - 4C X 90 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. | De-coiling / coiling of the cables 4CX50 - 4C X 90 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. |
| 189 | De-coiling / coiling of the cables 4CX120 - 4C X 240 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. | De-coiling / coiling of the cables 4CX120 - 4C X 240 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. |
| 190 | De-coiling / coiling of the cables 4CX300 - 4C X 400 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. | De-coiling / coiling of the cables 4CX300 - 4C X 400 sq mm XLPE, 1.1 KV cable : systematic decoiling of electrical cables from drums. The contractor shall provide and utilise certified cable drum jacks (hydraulic or mechanical) of adequate capacity to ensure smooth rotation and prevent kinking or insulation damage. Coiling shall include the orderly coiling, bundling, and tagging of all surplus or recovered cable lengths for return to the designated site area. |
| 191 | Preventive Maintenance and Up keeping of LT Switchgear Panels & Distribution Boards :a. Visual & Physical Inspection: Detailed assessment of panel enclosures for structural integrity and the condition of cable entry glands, terminations, and terminal lugs. The contractor shall ensure all connections remain tight. b. Verification of the operational status of all analogue/digital meters, selector switches, and LED indication lamps. Faulty indicators or non-functional meters must be reported for immediate rectification.c. Recording of electrical parameters and thermal monitoring of busbar joints, lugs, and terminations using a non-contact infrared (IR) temperature gun. d. Servicing of panel doors and locking mechanisms, including cleaning and greasing of hinges/latches.e. General cleaning of the panel and panel room, including cobweb removal, ensuring the floor area is kept clear of scrap or hazardous materials to maintain safe working clearances. | Preventive Maintenance and Up keeping of LT Switchgear Panels & Distribution Boards :a. Visual & Physical Inspection: Detailed assessment of panel enclosures for structural integrity and the condition of cable entry glands, terminations, and terminal lugs. The contractor shall ensure all connections remain tight. b. Verification of the operational status of all analogue/digital meters, selector switches, and LED indication lamps. Faulty indicators or non-functional meters must be reported for immediate rectification.c. Recording of electrical parameters and thermal monitoring of busbar joints, lugs, and terminations using a non-contact infrared (IR) temperature gun. d. Servicing of panel doors and locking mechanisms, including cleaning and greasing of hinges/latches.e. General cleaning of the panel and panel room, including cobweb removal, ensuring the floor area is kept clear of scrap or hazardous materials to maintain safe working clearances. |
| 192 | Carriage of departmental material, including cable of weight up to 50 kg, safely from a departmental office or cable yard or any other designated point in the Priyadarshini & Admin. Bldg to another designated place within the Priyadarshini & Admin. Bldg and vice versa. The scope shall include loading and unloading and arrangement of a handcart or truck as per requirement. | Carriage of departmental material, including cable of weight up to 50 kg, safely from a departmental office or cable yard or any other designated point in the Priyadarshini & Admin. Bldg to another designated place within the Priyadarshini & Admin. Bldg and vice versa. The scope shall include loading and unloading and arrangement of a handcart or truck as per requirement. |
| 193 | Carriage of departmental material, including cable of weight up to 500 kg, safely from a departmental office or cable yard or any other designated point in the Priyadarshini & Admin. Bldg to another designated place within the Priyadarshini & Admin. Bldg and vice versa. The scope shall include loading and unloading and arrangement of a handcart or truck as per requirement. | Carriage of departmental material, including cable of weight up to 500 kg, safely from a departmental office or cable yard or any other designated point in the Priyadarshini & Admin. Bldg to another designated place within the Priyadarshini & Admin. Bldg and vice versa. The scope shall include loading and unloading and arrangement of a handcart or truck as per requirement. |
| 194 | Carriage of departmental material, including cable of weight up to 1000 kg, safely from a departmental office or cable yard or any other designated point in the Priyadarshini & Admin. Bldg to another designated place within the Priyadarshini & Admin. Bldg and vice versa. The scope shall include loading and unloading and arrangement of a handcart or truck as per requirement. | Carriage of departmental material, including cable of weight up to 1000 kg, safely from a departmental office or cable yard or any other designated point in the Priyadarshini & Admin. Bldg to another designated place within the Priyadarshini & Admin. Bldg and vice versa. The scope shall include loading and unloading and arrangement of a handcart or truck as per requirement. |
| 195 | Loading or unloading of the department material or scrap from the electrical store / scrap yard / plant area up to 500 Kg within the RCF factory premise or Priyadarshini or Priyadarshini & Admin. Bldg area with a departmentally provided truck. All tools, tackles and PPE shall be ensured by the contractor. | Loading or unloading of the department material or scrap from the electrical store / scrap yard / plant area up to 500 Kg within the RCF factory premise or Priyadarshini or Priyadarshini & Admin. Bldg area with a departmentally provided truck. All tools, tackles and PPE shall be ensured by the contractor. |
| 196 | Connecting copper cable of size up to 4 C X 16 sqmm by supplying and crimping suitable copper lugs | Connecting copper cable of size up to 4 C X 16 sqmm by supplying and crimping suitable copper lugs |
| 197 | Carriage,installation and commissioning (removal) of departmentally supplied bay light or equivalent up to height of 5 mtrs directly on ceiling or wall.Materials like clamp screw, square box etc with consumables shall be supplied by the contractor | Carriage,installation and commissioning (removal) of departmentally supplied bay light or equivalent up to height of 5 mtrs directly on ceiling or wall.Materials like clamp screw, square box etc with consumables shall be supplied by the contractor |
| 198 | Painting of garden ligth pole MS/GI of height 7 feet above the ground with OD of 40 or 50 mm by removing rust and with two coats of silver paint | Painting of garden ligth pole MS/GI of height 7 feet above the ground with OD of 40 or 50 mm by removing rust and with two coats of silver paint |
| 199 | Carriage, installation and commissioning of a decorative light pole/GI pole up to the height of 7.5 meters on a provided foundation or base plate.The scope shall also include the assembling of the bracket/ fitting, JB and running the provided cable through the pole from JB to the fitting | Carriage, installation and commissioning of a decorative light pole/GI pole up to the height of 7.5 meters on a provided foundation or base plate.The scope shall also include the assembling of the bracket/ fitting, JB and running the provided cable through the pole from JB to the fitting |
| 200 | Supply & replacement of PVC Board of 4 x 4\\" . Make : PRESTO, PRESSFIT, GOLD MEDEL | Supply & replacement of PVC Board of 4 x 4\\" . Make : PRESTO, PRESSFIT, GOLD MEDEL |
| 201 | Supply & replacement of PVC Board of 4 x 7\\". Make : PRESTO, PRESSFIT, GOLD MEDEL | Supply & replacement of PVC Board of 4 x 7\\". Make : PRESTO, PRESSFIT, GOLD MEDEL |
| 202 | Supply & replacement of PVC Board of 6 x 8\\". Make : PRESTO, PRESSFIT, GOLD MEDEL | Supply & replacement of PVC Board of 6 x 8\\". Make : PRESTO, PRESSFIT, GOLD MEDEL |
| 203 | Supply & replacement of PVC Board of 8 x 10\\". Make : PRESTO, PRESSFIT, GOLD MEDEL | Supply & replacement of PVC Board of 8 x 10\\". Make : PRESTO, PRESSFIT, GOLD MEDEL |
| 204 | Supply & replacement of PVC Board of 10 x 12\\". Make : PRESTO, PRESSFIT, GOLD MEDEL | Supply & replacement of PVC Board of 10 x 12\\". Make : PRESTO, PRESSFIT, GOLD MEDEL |
| 205 | Supply, installation and commissioning of decorative Wall mounted Dual-light vanity luminaire in Priyadarshini & Admin. Bldg: Dual-light vanity fitting with matte black /bronze finish metal body and cylindrical frosted glass shades. To include all mounting hardware and internal wiring. Approval must be taken from site-in-charge before the intallation and commissioning. | Supply, installation and commissioning of decorative Wall mounted Dual-light vanity luminaire in Priyadarshini & Admin. Bldg: Dual-light vanity fitting with matte black /bronze finish metal body and cylindrical frosted glass shades. To include all mounting hardware and internal wiring. Approval must be taken from site-in-charge before the intallation and commissioning. |
| 206 | Supply, installation, and commissioning of a decorative wall-mounted lantern featuring a traditional \\"coach\\" silhouette with an industrial aesthetic. The fixture shall consist of a gooseneck support arm, a conical ventilated cap, and a flared cage housing a clear glass diffuser. | Supply, installation, and commissioning of a decorative wall-mounted lantern featuring a traditional \\"coach\\" silhouette with an industrial aesthetic. The fixture shall consist of a gooseneck support arm, a conical ventilated cap, and a flared cage housing a clear glass diffuser. |
| 207 | Providing and installing decorative series lamps complete with connections, testing etc. at various locations on lawns, buildings and gates etc of Priyadarshini & Admin. Bldglows, Priyadarshini & Admin. Bldg Qty - 10000. | Providing and installing decorative series lamps complete with connections, testing etc. at various locations on lawns, buildings and gates etc of Priyadarshini & Admin. Bldglows, Priyadarshini & Admin. Bldg Qty - 10000. |
| 208 | Providing and installing decorative running strip lamps pattis of 300 lamp complete with connection. Testing etc.. at various locations on lawns, of Priyadarshini & Admin. Bldg etc. | Providing and installing decorative running strip lamps pattis of 300 lamp complete with connection. Testing etc.. at various locations on lawns, of Priyadarshini & Admin. Bldg etc. |
| 209 | Providing and installing decorative Rice lamp, complete with connections, testing etc. at various locations on lawns,and gates etc of Priyadarshini & Admin. (Unit rate quoted shall be for 100 nos per day) | Providing and installing decorative Rice lamp, complete with connections, testing etc. at various locations on lawns,and gates etc of Priyadarshini & Admin. (Unit rate quoted shall be for 100 nos per day) |
| 210 | Identifying under ground power cable / metalic pipe line with emf locator etc and giving clearence for digging | Identifying under ground power cable / metalic pipe line with emf locator etc and giving clearence for digging |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender