Tender for Repair And Maintenance Of The Various Perimeter Lights, Flood Lights Along With High Mast Lights With Lt Cables Under Ge(West)Pathankot
BOQ
| Sl. No. | Item Description |
| 1 | S&F in replacement LED street light fitting 60 watts, IP 66 power factor >0.95, IK-08 having 120 lm/W efficacy with individual lens cover on each LED, rendering index > 70, 4 kV integrated surge protection, external 10 kV surge protection potted driver, toughened glass cover in high pressure die-cast powder coated aluminium housing with input voltage 140–270 V, 50 Hz, Power consumption -60 watts with safety class-Class-I with IEC standard, with LM 79 and LM-80 certification, with Median useful life L70B50-50,000 hour(s) as per IEC making connection using 3 core flexible copper cable complete all as specified and directed by Engineer-in-charge. |
| 2 | All as per sri item No.1 here-in-before but 70 watt |
| 3 | All as per sri item No.1 here-in-before but 90 watt |
| 4 | All as per sri item No.1 here-in-before but 120 watt |
| 5 | All as per sri item No.1 here-in-before but LED flood light 150 watt. |
| 6 | All as per srl item No.1 here-in-before but LED flood light 250 watt. |
| 7 | Note for item no. 01 to 06 :- (a) Operating temperature of fitting shall be 10 to 50 degree Centigrade and voltage range of 120 V-270V, (b) The OEM Warranty certificate to be submitted to AGE E/M after completion of work, (c) LM-79 (not more than 1 year old) LM-80 reports for fitting are mandatory, (d) The fitting shall have minimum 3 years warranty with L70B50 report., (e) BIS stamp is mandatory on fixture & driver, (f) All lights should be NABL Tested and calibrated with due certification.) |
| 8 | S&F replacement potted driver with 4 kV surge protection suitable for street/Flood light fitting of size 25 W-45W of make as per existing ground. |
| 9 | All as per sri item No.7 here-in-before but size of 60 W-70W |
| 10 | All as per sri item No.7 here-in-before but size of 90 W-120W |
| 11 | All as per sri item No.7 here-in-before but size of 130 W-150W |
| 12 | S&F replacement external surge protection of 10 kV |
| 13 | S&F in replacement power contactor 3P, 25 A |
| 14 | S&F in replacement MCB SPN of Cap 6-32 AMP C curve |
| 15 | M&L for bracket in replacement for fixing of street light fittings bend to shape, made out of 32 mm dia Gl pipe medium grade upto 1.5 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. |
| 16 | S&F in repair twin core Aluminium conductor PVC insulated cable of size 4 sqmm FR multi stranded 1100 volts grade complete all as directed by Engineer-in-Charge. |
| 17 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in any type of soil for laying of cable pole foundation, stay, laying of pipe etc complete all as specified and directed. |
| 18 | All as per item No. 16 here-in-before but exceeding 1.5m in depth |
| 19 | Returning filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm complete all as specified. |
| 20 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified |
| 21 | M&L for Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed. |
| 22 | Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified. |
| 23 | Supply, laying and testing, in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 4 core, conforming to IS -7098 Part-I complete all as specified |
| 24 | Supply, laying and testing, in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sq. mm 4 core, conforming to IS -7098 Part-I complete all as specified |
| 25 | Supply, laying and testing, in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 10 sq. mm 2 core, conforming to IS -7098 Part-I complete all as specified |
| 26 | Supply, laying and testing, in replacement LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq. mm 3.5 core, conforming to IS -7098 Part-I complete all as specified |
| 27 | M&L for Gl tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including taking up or down 40 or 50 mm dia |
| 28 | S&F in replacement cable junction box made out of poly carbonate duly powder coated in grey colour, of size Each min 150 X 200 X 75 mm shock proof, termite proof, weather proof, UV-resistant, temperature resistant, IP 65, IK 09, with aluminium bus bar terminals, including MCB SP of rating 6 to 32 Amps and entry/exit of XLPE cable upto the size of 35 Sqmm 2 core, fitted on pole with clamp made out of 20 X 2 mm strip and cable glands of PVC type complete all as specified and directed by Engineer-in-Charge |
| 29 | S&F in replacement automatic street light timer switch, with in built of Nature switch suitable to take load of minimum 8 kw, 3 phase based on weather proof automatic sensor alongwith suitable power contactor & MCB TPN 63 Amp on both input and output duly prewired with suitable size of copper wiring with proper lugs and terminal blocks with facility of manual ON/OFF switch complete enclosed in polycarbonate IP 54 enclosure shock, rust, weather & termite proof uv-resistant, FR grade fixed on pole with MS strip of size 20 X 2 mm complete all as specified & directed by Engineer-in-charge It should include Automatic switching ON at dusk Automatic switching OFF at dawn with No clock settings and no time settings No need of seasonal resetting Wide operating voltage range High voltage trip and auto reset Low voltage trip and auto reset MCB-based overload trip and latch Degree of protection conforms to IP 54 Immunity to dust, bird sittings, etc.complete all as specified and directed by Engineer-in-Charge |
| 30 | S&F in replacement automatic street light timer switch, with in built of Nature switch suitable to take load of minimum 3 kw, 1 phase based on weather proof automatic sensor alongwith suitable power contactor & MCB SPN 32 Amp on both input and output duly prewired with suitable size of copper wiring with proper lugs and terminal blocks with facility of manual ON/OFF switch complete enclosed in polycarbonate IP 54 enclosure shock, rust, weather & termite proof uv-resistant, FR grade fixed on pole with MS strip of size 20 X 2 mm complete all as specified & directed by Engineer-in-charge it should include Automatic switching ON at dusk Automatic switching OFF at dawn with No clock settings and no time settings No need of seasonal resetting Wide operating voltage range High voltage trip and auto reset Low voltage trip and auto reset MCB-based overload trip and latch Degree of protection conforms to IP 54 Immunity to dust, bird sittings, etc.complete all as specified and directed by Engineer-in-Charge |
| 31 | M&L for painting of steel tubular pole 9/11 metre including clamps and other MS item etc complete on pole with two coats of aluminium paints after preparing the surface dirt/ grease free including all mechanism all as specified and directed by Engineer-in-Charge |
| 32 | M&L for Prestressed concrete pole, 9.0 metres long 102mm x 152mm at top and 102 mm x 289 mm at bottom. class 10 in replacement including dismantling of old UNSV pole, numbering new pole and applying two coats of synthetic enamel paint upto 1.5 m from top of coping in 30 cm hgh strip of black and white alternately (Note:-Earth work as excavation, removing and returning filling, PCC work will be measured and paid separately under respective items) |
| 33 | M&L for providing Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping, cable duct, cover slab and benching including all necessary form work complete all as specified and directed. |
| 34 | M&L for providing PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete all as specified and as directed. |
| 35 | S&F in repair single run of PVC insulated and PVC Sheathed cable HR with copper conductor of size 3 core x 1.5 sqmm & necessary conduit pipe of size 20mm for protection from wind/sunlight proper clamping etc from JB to bracket of streetlight copper conductor cable of size 1.5 sqmm three-core all as required and specified by Engineer-in-Charge |
| 36 | M&L for repairing of LT panel of various high mast Lighting system of various heights outdoor type with repair and replace of damaged door hinges set of three nos of front and back side and legs along with necessary cutting welding and drilling etc including painting to LT panel and duct cover etc along with angle iron frame with 2 coats of grey or white colour or as approved by Engineer-in-Charge as per site suitability with approved make synthetic enamel paint complete making it aesthetic good and durable for the Longevity all as directed by Engineer-in-Charge. |
| 37 | M&L for Repairing the winching mechanism of a high mast lighting system with strict adherence to industry standards for mechanical lifting and structural stability. It includes all necessary repairs to the Operating Mechanism: Double-drum, fully motorized raising and lowering unit making it capable of operating via a high-powered electric drive with a manual override including checking its Safety & Braking: It includes all necessary repairs to worn springs, or clutches that are wear out including High Mast Wire Ropes/Multi-strand stainless steel (grade AISI 316/7 19 construction) with a minimum tensile strength of ≥ 165 Kgf/mm² and diameter typically 6 mm or greater. If a wire rope has slipped or tangled, resetting required to be done with extreme caution and should strictly be done by qualified technicians. Winch gears must be lubricated with reputed high-viscosity Industrial oil (e.g., SAE 90 or SAE 140) and topped up/replaced according to standard guidelines For Lowering the Carriage all necessary repairs are required with Lowering the lantern carriage to resting pads or stands. It required all Slack Adjustment with Carefully loosen the wire ropes using the manual handle or power tool until the carriage sits securely. All necessary precautions and repairs to be carried out in for the grooved drum where the luminaire can be fully lowered with motor as well as manually Necessary Testing & Tensioning has to be carried out to Operate the winch (raising and lowering) at a regulated speed (typically 3.0 m/min) to ensure the cable winds evenly without overlaps.All Required Replacement Parts included as and when required in the Job including major as well as minor components for the winching system including mainly Wire Ropes / Continuous stainless steel ropes (conforming to IS-2365 and IS-3457 standards) with no intermediate joints from the winch to the headframe Lubricants, motors or its repairing or rewinding etc. The necessary repairs to internally mounted power tool included in the job ranges typically 0.75 HP up to 3.0 HP). Complete testing and operation has to be performed after all repairs and making the complete winching system functional all as specified and directed by Engineer-in-Charge. |
| 38 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 1,55,025.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender