Tender For Steel Rate Contract - Qtr Iii 2026 - 27- Requirement Of Steel Plates, Sheets & Coils
Tender Overview
Project Description
Tender for Steel Rate Contract - Qtr Iii 2026 - 27- Requirement Of Steel Plates, Sheets & Coils , Cr Coil 0.63X700 Is 513 Cr3 Dd Tdc:Rta:408:R04; 0.63 X 700 X Coil Form [T X W X L] [Mm] , Cr Coil 0.63X813 X Coil Form; Is 513 Dd; Tdc:Rta:408; 0.63 X 813 X Coil Form [T X W X L] [Mm] , Cr Coil 0.63X915 X Coil Form; Is 513 Dd; Tdc:Rta:408; 0.63 X 915 X Coil Form [T X W X L] [Mm] , Gp Sheet 0.63 Mm Class Viii Is 277; 0.63 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Cr Coil 0.80X650 Is 513 Cr3 Dd Tdc:Rta:408:R04; 0.8 X 650 X Coil Form [T X W X L] [Mm] , Cold Rolled Coil 1.25 X 903 Is 513 Gr.Cr3 Tdc:Rte:257 Rev:04; 1.25 X 903 X Coil Form [T X W X L] [Mm] , Cr Sheet 1.6 Mm Is 513 Cr2 - Kld; 1.6 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheets 1.6 Mm Is 1079 Gr.Hr2 Sk/K; 1.6 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheet 2 Mm Is 5986 Gr 205; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Cr Sheet 2.0 Mm Is 513 Cr2 - Kld; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Cr Sheet 2.0 Mm Is 513 Cr2 - Kld; 2 X 1250 X 2500 [T X W X L] [Mm] , Hr Sheets 2 Mm Is 1079 Gr.Hr1 Sk/K; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheets 2 Mm Is 1079 Gr.Hr2 Sk/K; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheet 2.5 Mm Is 5986 Gr 205; 2.5 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheets 2.5 Mm Is 1079 Gr.Hr2 Sk/K; 2.5 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , 3.0 Mm X 1250 Mm X 2500 Mm Crc Steel Sheets Annealed To Specification Aa 10115 Rev-09 (Is 513 Cr2 Kld); 3 X W=1250 X L=2500 [T X W X L] [Mm] , Hr Sheet 3.15 Mm Is 5986 Gr 205; 3.15 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheets 3.15 Mm Is 1079 Gr.Hr1 Sk/K; 3.15 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheets 3.15 Mm Is 1079 Gr.Hr2 Sk/K; 3.15 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheet 4.0Mm Is 5986 Gr 205; 4 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Hr Sheets 4 Mm Is 1079 Gr.Hr2 Sk/K; 4 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [Mm] , Pl 4 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 4 (T) X 900/ 1200/ 1235/ 1500 (W) X 2500 (L) [Mm]; 4 X 900/1200/1235/1500 X 2500 [T X W X L] [Mm] , Pl 5 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 5 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [Mm] , Pl 5 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 5 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [Mm] , Cq Pl 5 Mm Is 3502; 5 X 900 ≤ W ≤ 1250 X L ≤ 6300 [T X W X L] [Mm] , Pl 5 Mm Is2062 E250 Gr Br/K Tdc:386; 5 (T) X 1500 ≤ W ≤ 1800 (W) X (6300-12000) (L) [Mm]; 5 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 5 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 5 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [Mm]; 5 X 1200/1235/1500 X 6500 [T X W X L] [Mm] , Pl 6 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 6 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [Mm] , Pl 6 Mm Is 2062 E 250 Gr A/Br/Sk/K; 6 X W ≤ 1250 X L ≤ 6300 [T X W X L] [Mm] , Pl 6 Mm Is2062 E350 Gr B0/K Tdc:301; 6 (T) X 1500 ≤ W ≤ 1800 (W) X (6300-12000) (L) [Mm]; 6 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 6 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 6 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [Mm] , Pl 6 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 6 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Cq Pl 6 Mm Is 3502; 6 X 900 ≤ W ≤ 1250 X L ≤ 6300 [T X W X L] [Mm] , Pl 6 Mm Is2062 E250 Gr Br/K ; Tdc:301 ; 6 (T) X 1500 ≤ W ≤ 1800 (W) X (6300-12000) (L) [Mm]; 6 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 6 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 6 (T) X 2000 (W) X (6300-12000) (L) Mm; 6 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 6 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 6 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [Mm]; 6 X 1200/1235/1500 X 6500 [T X W X L] [Mm] , Pl 6 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 6 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [Mm]; 6 X 1200/1235/1500 X 6500 [T X W X L] [Mm] , Pl 7 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 7 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [Mm] , Pl 8 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 8 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 8 Mm Is 2062 E 250 Gr A/Br/Sk/K Tdc:301 Rev 12; 8 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 8 Mm Is2062 E350 Gr Br/K Tdc 301 Rev12, Width 2500 Mm, Length 9000 Mm; 8 X 2500 X 9000 [T X W X L] [Mm] , Pl 8 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 8 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 8 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 8 X 2900 X 10000 [T X W X L] [Mm] , Pl 8 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 8 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 8 Mm Is2062 E350 Gr B0/K Tdc:386; 8 (T) X 2000 (W) X (6300-12000) (L) [Mm]; 8 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 8 Mm Is2062 E350 Gr B0/K Tdc:386; 8 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 8 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Cq Pl 8 Mm Is 3502; 8 X 900 ≤ W ≤1250 X L ≤ 6300 [T X W X L] [Mm] , Pl 8 Mm Is2062 E250 Gr Br/K Tdc:301; 8 (T) X 2000 (W) X (6300-12000) (L) [Mm]; 8 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 8 Mm Is2062 E250 Gr Br/K Tdc:386; 8 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 8 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 8 Mm Is 2062 E250br/K Tdc:6:386,; 8 X 2500 X 12000 [T X W X L] [Mm] , Plate 8.00 Mm - Sa515gr70; 8 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 8 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 8 (T) X 1200/ 1235/ 1500 (W) X 7500 (L) [Mm]; 8 X 1200/1235/1500 X 7500 [T X W X L] [Mm] , Pl 8 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 8 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [Mm]; 8 X 1200/1235/1500 X 7500 [T X W X L] [Mm] , Pl 10 Mm Is2062 E350 Gr Br/K Tdc:386; 10 (T) X 2000 (W) X (6300-12000) (L) [Mm]; 10 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 10 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [Mm] , Pl 10 Mm Is 2062 E 250 Gr A/Br/Sk/K Tdc:301 Rev 12; 10 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 10 Mm Is 2062 E250br/K Tdc 301 , Width 2000Mm, Length 12000 Mm; 10 X 2000 X 12000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E350 Gr B0/K Tdc:301; 10 (T) X 2500 (W) X (6300-12000) (L); 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E350 Gr B0/K Tdc:301; 10 (T) X 2000 (W) X (6300-12000) (L); 10 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 10 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 10 Mm Is 2062 E250br/K Tdc:6:386, Width 2500Mm, Length 10000Mm; 10 X 2500 X 10000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E350 Gr B0/K Tdc:386; 10 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Cq Pl 10 Mm Is 3502; 10 X 900 ≤ W ≤1250 X L ≤ 6300 [T X W X L] [Mm] , Pl 10 Mm Is2062 E250 Gr Br/K Tdc:301; 10 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 10 (T) X 2000 (W) X (6300-12000) (L) Mm; 10 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E250 Gr Br/K Tdc:386; 10 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 10 Mm Is2062 E250 Gr Br./K; Tdc:386 + Normalizing Rolling; 10 (T) X 2500 (W) X 12500 (L) [Mm]; 10 X 2500 X 12500 [T X W X L] [Mm] , Pl 10 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 10 X 2500 X 6500 [T X W X L] [Mm]; 10 X 2500 X 6500 [T X W X L] [Mm] , Plate 10.0 Mm - Sa515gr70; 10 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 10 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 10 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 10 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 10 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 10 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 10 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 12 Mm Is2062 E350 Gr Br/K Tdc:386; 12 (T) X 2500 (W) X (6300-12000) (L) [Mm; 12 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 12 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 12 X W= 2500 X 1000 ≤ L ≤ 12500 [T X W X L] [Mm] , Pl 12 Mm Is 2062 E 250 Gr A/Br/Sk/K Tdc:301 Rev 12; 12 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 12 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 12 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 12 Mm Is 2062 E250br/K Tdc:6:386, Width 2500Mm, Length 12000Mm; 12 X 2500 X 12000 [T X W X L] [Mm] , Pi 12 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 12 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 12 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 12 (T) X 2000 (W) X (6300-12000) (L) Mm; 12 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 12 Mm Is2062 E250 Gr Br/K Tdc:386; 12 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 12 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 12 Mm Is2062 E250 Gr Br./K; Tdc:386 + Normalizing Rolling; 12 (T) X 2500 (W) X 10000 (L) [Mm]; 12 X 2500 X 10000 [T X W X L] [Mm] , Pl 12 Mm Is2062 E350 Gr B0/K Tdc:386; 12 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 12 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 12Mm A516 Gr. 70; Tdc: Aa10403 Rev 01 + Supplementry Rquirements: Impact Test (S5 + Sl. No. 1 & 2 Of Annexure- 1)+Bend Test (Sl. No. 5 Of Annexure-1) .; 12 X 3000 X 8000 L 12000 [T X W X L] [Mm] , Plate 12.0 Mm - Sa515gr70; 12 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 12 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 12 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 12 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 12 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 12 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 12 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 12.7 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 12.7 X 3750 X 5850 [T X W X L] [Mm] , Pl 14 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 14 Mm X 2500 Mm X 6500 Mm : T X W X L (Mm); 14 X 2500 X 6500 [T X W X L] [Mm] , Plt Bq 14 Mm (Sa516 Gr70) Tdc: Aa10403 + Ibr (Sl.No. 3.6.1 Of Aa10403)+Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) +Bend Test( Sl. No. 5 Of Annexure-1 Of Aa10403); 14 X 2000 X 8000 [T X W X L] [Mm]; 14 X 2000 X 8000 [T X W X L] [Mm] , Pl 16 Mm Is2062 E250 Gr Br/K Tdc 301 Rev 12; 16 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [Mm] , Pl 16 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 16 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 16 Mm Is 2062 E250br/K Tdc:6:386, Width 2500Mm, Length 12000Mm; 16 X 2500 X 12000 [T X W X L] [Mm] , Pl 16 Mm Is2062 E250 Gr Br/K Tdc:301; 16 (T) X 2000 (W) X (6300-12000) (L) [Mm]; 16 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 16 Mm Is2062 E250 Gr Br/K ;Tdc 301 Rev 12; (Impact Test At Room Temperature Is Mandatory); Ut As Per Astm A435: 16 X 2500 X 6300 ; T (Mm) X W (Mm) X L (Mm); 16 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 16 Mm Is2062 E350 Gr Br/K Tdc:301; 16 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 16 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 16 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 16 (T) X 2500 (W) X (6300-12000) (L) Mm; 16 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 16 Mm Is 2062 E250 Gr Br_Tdc:6:386 Rev 03; 16 X 3400 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 16 Mm Is2062 E250 Gr Br/K; Tdc:386 + Normalising + Ust As Per Astm A578 Level B, 16 (T) X 2500 (W) X 12500 (L) [Mm]; 16 X 2500 X 12500 [T X W X L] [Mm] , Pl 16 Mm Is2062 E350 Gr B0/K Tdc:386; 16 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 16 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 16 Mm A516 Grade-70- Supplementary Requirements: Impact Test (S5 + Sl. No. 2 & 3 Of Annexure-1); 16 X 2000≤ W ≤2500 X 8000 ≤ L ≤12500 [T X W X L] [Mm] , Pl 16 Mm A516 Grade-70; Tdc : Aa10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 Of Annexure-1) + Bend Test( Sl. No. 5 Of Annexure-1); 16 X 2500 X 5700 [T X W X L] [Mm]; 16 X 2500 X 5700 [T X W X L] [Mm] , Pl 16 Mm A516 Grade-70; Tdc : Aa10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 Of Annexure-1) + Bend Test( Sl. No. 5 Of Annexure-1); 16 X 2500 X 7500 [T X W X L] [Mm] , Pl 16 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 16 X 2500 X 6300 [T X W X L] [Mm] , Plt Bq 16 Mm (Sa516 Gr 70) Tdc: Aa10403 + Ibr (Sl.No. 3.6.1 Of Aa10403)+Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Bend Test( Sl. No. 5 Of Annexure-1 Of Aa10403); 16 X 2000 X 10000 [T X W X L] [Mm; 16 X 2000 X 10000 [T X W X L] [Mm] , Plt Bq 16 Mm (Sa516 Gr 70) Tdc: Aa10403 + Ibr (Sl.No. 3.6.1 Of Aa10403)+Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Bend Test( Sl. No. 5 Of Annexure-1 Of Aa10403); 16 X 2500 X (6300 ≤ L ≤ 10000) [T X W X L] [Mm]; 16 X 2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 16 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 16 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 16 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 16 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 16 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 16 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 18 Mm Is2062 E350 Gr Br/K Tdc:301; 18 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 18 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 20 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [Mm] , Plate-20 Is2062 E250br Tdc:301 Rev 12; 20 X 2500 X 7925 [T X W X L] [Mm] , Pi 20 Mm Is2062 E350 Gr Br Tdc 301 Rev 12; 20 X W= 2500 X L = 12000 [T X W X L] [Mm] , Plate 20.0 Mm; Is2062e350 Gr B0; Tdc:6:386:Rev:03: 20 X 2500 X (10000-12000) (T X W X L) Mm; 20 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr Br/K ;Tdc 301 Rev 12; (Impact Test At Room Temperature Is Mandatory); Ut As Per Astm A435: 20 X 2500 X 6300 ; T (Mm) X W (Mm) X L (Mm); 20 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr Br/K Tdc:301; 20 (T) X 2000 (W) X (6300-12000) (L) [Mm]; 20 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr. Br; Tdc 301; 20 (T) X 2500 (W) X 11425 (L) [Mm]; 20 X 2500 X 11425 [T X W X L] [Mm] , Pl 20 Mm Is2062 E350 Gr Br/K Tdc:301; 20 (T) X 2000 (W) X (6300-12000) (L) [Mm]; 20 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 20 (T) X 2000 (W) X (6300-12000) (L) Mm; 20 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 20 (T) X 2500 (W) X (6300-12000) (L) Mm; 20 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 20 X 2500 X 7100 [T X W X L] [Mm]; 20 X 2500 X 7100 [T X W X L] [Mm] , Pl 20 Mm Is2062 E250 Gr Br/K; Tdc:386 + Normalising + Ust As Per Astm A578 Level B, 20 (T) X 2500 (W) X 12500 (L) [Mm]; 20 X 2500 X 12500 [T X W X L] [Mm] , Pl 20 Mm Is2062 E350 Gr B0/K Tdc:386; 20 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 20 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 20 Mm Is2062 E350 Gr B0; Tdc:386; 20 (T) X 2200 (W) X (10000-12000) (L) [Mm]; 20 X 2200 X (10000-12000) [T X W X L] [Mm] , Plate 20.0 Mm - Sa515gr70; 20 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 20 Mm A516 Grade-70; Tdc : Aa10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 Of Annexure-1) + Bend Test( Sl. No. 5 Of Annexure-1); 20 X 2500 X 6300 [T X W X L] [Mm] , Pl 20 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 20 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 20 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 20 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 20 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 20 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 22 Mm A515 Grade-70; Aa10404; 22 X 3000 X 10000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E350 Gr Br/K Tdc:386; 25 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E250 Gr Br/K Tdc 301 Rev 12; 25 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [Mm] , Pl 25 Mm Is2062 E350 Gr Br/K Tdc:301; 25 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E350 Gr Br/K Tdc:301; 25 (T) X 2000 (W) X (6300-12000) (L) [Mm]; 25 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 25 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pi 25 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 25 X W= 2500 X L= 12000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E250 Gr Br/K ;Tdc 301 Rev 12; (Impact Test At Room Temperature Is Mandatory); Ut As Per Astm A435: 25 X 2500 X 6300 ; T (Mm) X W (Mm) X L (Mm); 25 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 25 Mm Is2062 E250 Gr Br/K Tdc:301 Rev 03; 25 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E250 Gr Br/K; Tdc 301 + Ust As Per Astm A435, 25 (T) X 2500 (W) X 12500 (L) [Mm]; 25 X 2500 X 12500 [T X W X L] [Mm] , Pl.25 X 2500 X 12000 Is 2062 E250 Gr. Br. Tdc 6 386 Rev.03; 25 X 2500 X 12000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 25 (T) X 2500 (W) X (6300-12000) (L) Mm; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 25 Mm Is2062 E350 Gr B0/K Tdc:386; 25 (T) X 2500 (W) X (6300-12000) (L) [Mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Plate 25.0 Mm - Sa515gr70; 25 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 25 Mm Sa515 Grade-70 Aa10404-05 + Supplementary Requirements: Charpy-V-Test (Longitudinal / Transverse Sample) Shall Be Performed Getting Values Of Kv 27 J At -20°C Or Kv 34 J At 0°C Or Kv 40 J At 20°C .; 25 X 3100 X 6700 [T X W X L] [Mm] , Plt Bq 25 Mm (Sa516 Gr70) Tdc: Aa10403 +Ibr (Sl.No. 3.6.1 Of Aa10403) + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Bend Test( Sl. No. 5 Of Annexure-1 Of Aa10403)+ Simulation Heat Treatment (S5 + Sl.No.8 Of Annexure 1 Of Aa10403); No. Of Cycles Required In Sht: 01 Cycle For 3 Hrs Or 3 Cycles For 1 Hr.; 25 X 2500 X 13000 [T X W X L] [Mm]; 25 X 2500 X 13000 [T X W X L] [Mm] , Pl Bq 25 Mm (Sa516 Gr70) Tdc: Aa10403 +Ibr (Sl.No. 3.6.1 Of Aa10403) + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Bend Test (Sl. No. 5 Of Annexure-1 Of Aa10403) + Simulation Heat Treatment (S5 + Sl.No.8 Of Annexure 1 Of Aa10403); No. Of Cycles Required In Sht: 01 Cycle For 3 Hrs Or 3 Cycles For 1 Hr.; 25 X 2500 X 10000 [T X W X L] [Mm]; 25 X 2500 X 10000 [T X W X L] [Mm] , Pl 25 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 25 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 25 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 25 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 25 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [Mm]; 25 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [Mm] , Pl 28 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 28 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 28 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 28 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 28 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 28 X W= 2500 X L= 12000 [T X W X L] [Mm] , Pl 28 Mm Is2062 E250 Gr Br/K ;Tdc 301 Rev 12; (Impact Test At Room Temperature Is Mandatory); Ut As Per Astm A435: 28 X 2500 X 6300 ; T (Mm) X W (Mm) X L (Mm); 28 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 28 Mm Is2062 E350 Gr B0; Tdc:386; 28 (T) X 2200 (W) X (10000-12000) (L) [Mm]; 28 X 2200 X (10000-12000) [T X W X L] [Mm] , Plt Bq 28 Mm (Sa516 Gr70) Tdc: Aa10403 + Ibr (Sl.No. 3.6.1 Of Aa10403) + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Bend Test( Sl. No. 5 Of Annexure-1 Of Aa10403)+ Simulation Heat Treatment (S5 + Sl.No.8 Of Annexure 1 Of Aa10403); No. Of Cycles Required In Sht: 01 Cycle For 3 Hrs Or 3 Cycles For 1 Hr.; 28 X 2500 X 13000 [T X W X L] [Mm]; 28 X 2500 X 13000 [T X W X L] [Mm] , Pl 30 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;30 Mm X 1500 Mm X 8000 Mm : T X W X L (Mm); 30 X 1500 X 8000 [T X W X L] [Mm] , Pi 30 Mm Is2062 E250 Gr Br Tdc:6:386 Rev 03; 30 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Plate 30.0 Mm - Sa515gr70; 30 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 30 Mm Sa515 Grade-70 Aa10404-05 + Supplementary Requirements: Impact Test At Room Temperature+Orientation Of The Test Specimen In Longitudinal Direction(S5); 30 X 4000 X 6750 [T X W X L] [Mm] , Pl 30 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 30 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [Mm]; 30 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [Mm] , Pl 32 Mm Is2062 E250 Gr A/Br/Sk/K Tdc:6:386 Rev 03; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 32 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 32 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [Mm] , Pl 32 Mm Is2062 E250 Gr Br/K Tdc 301 Rev 12 + Ust As Per Astm A435,Width 2500 Mm, Length 12500 Mm; 32 X W = 2500 X L = 12500 [T X W X L] [Mm] , Pi 32 Mm Is2062 E350 Gr Br Tdc 301 Rev 12; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 32 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pi 32 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pi 32 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 32 X W= 2500 X L= 12000 [T X W X L] [Mm] , Pl 32 Mm Is2062 E250 Gr Br/K ;Tdc 301 Rev 12; (Impact Test At Room Temperature Is Mandatory); Ut As Per Astm A435: 32 X 2500 X 6300 ; T (Mm) X W (Mm) X L (Mm); 32 X 2500 X L= 6300 [T X W X L] [Mm] , Pl 32 Mm Is2062 E250 Gr. Br/K Tdc 301; 32 (T) X 2500 (W) X 7500 (L) [Mm]; 32 X 2500 X 7500 [T X W X L] [Mm] , Plate 32.0 Mm - Sa515gr70; 32 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 32 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 32 X 2500 X 6300 ≤ L ≤ 10500 [T X W X L] [Mm] , Pl Bq 32Mm (Sa516 Gr70) Tdc: Aa10403 + Ibr (Sl.No. 3.6.1 Of Aa10403) + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Bend Test (Sl. No. 5 Of Annexure-1 Of Aa10403) + Simulation Heat Treatment (S5 + Sl.No.8 Of Annexure 1 Of Aa10403); No. Of Cycles Required In Sht: 01 Cycle For 3 Hrs Or 3 Cycles For 1 Hr.; 32 X 2500 X 10000 [T X W X L] [Mm]; 32 X 2500 X 10000 [T X W X L] [Mm] , Pl 32 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 32 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 32 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 32 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 32 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [Mm]; 32 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [Mm] , Pi 34 Mm Is2062 E350 Gr Br Tdc 301 Rev 12; 34 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 34 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 34 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 35 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;35 Mm X 1500 Mm X 8000 Mm : T X W X L (Mm); 35 X 1500 X 8000 [T X W X L] [Mm] , Plate 35.0 Mm - Sa515gr70; 35 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 36 Mm Is2062 E250 Gr Br/K Tdc 301 + Ust As Per Astm A435, Width 2500Mm, Length 12500Mm; 36 X W=2500 X L =12500 [T X W X L] [Mm] , Pi 36 Mm Is2062 E350 Gr Br/K Tdc 301 Rev 12; 36 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 36 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 36 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 36 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 36 X 4500 X 8500 [T X W X L] [Mm] , Pl 36 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 36 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 36 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 36 X W= 2500 X L= 12000 [T X W X L] [Mm] , Pl 36 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 36 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 36 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 36 Mm (Sa387 Gr22 Class 2 - Non Ibr); Tdc: Aa10648; 36 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [Mm]; 36 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [Mm] , Plate 38 Mm; Is2062 E350gr Br; Tdc::301:Rev:12: 38 X 2500 X (10000-12000) (T X W X L) Mm; 38 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 40 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 40 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 40 X W=3200 X L=6300 [T X W X L] [Mm] , Pi 40 Mm Is2062 E350 Gr Br Tdc 301 Rev 12; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 40 Mm Is2062 E350 Gr Br/K Tdc 301 Rev12 + Ust As Per Standard En 10160, Class S2/E2, Width 3200 Mm, Length 8000 Mm; 40 X 3200 X 8000 [T X W X L] [Mm] , Pl 40 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;40 Mm X 2500 Mm X 7500 Mm : T X W X L (Mm); 40 X 2500 X 7500 [T X W X L] [Mm] , Pl 40 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 40 X W= 3800 X L= 5700 [T X W X L] [Mm] , Pl 40 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 40 Mm Is 2062 E250br/K Tdc:6:386, Width 2500Mm, Length 12000Mm; 40 X 2500 X 12000 [T X W X L] [Mm] , Pl 40 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 40 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 40 X W= 2500 X L= 12000 [T X W X L] [Mm] , Plate 40.0 Mm; Is2062e350grb0; Tdc:6:386:Rev:03: 40 X 2500 X (10000-12000) (T X W X L) Mm; 40 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 40 Mm Is2062 E250 Gr Br/K; Tdc 301 Rev 12 + Ust As Per Astm A435, 40 (T) X 3200 (W) X 6300 (L) [Mm]; 40 X 3200 X 6300 [T X W X L] [Mm] , Plate 40 Mm; Is2062 E350gr Br; Tdc::301:Rev:12: 40 X 2500 X (10000-12000) (T X W X L) Mm; 40 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Plate 40 Mm; Is2062 E250grbr; Tdc:6:386:Rev:03: 40 X 2500 X (10000-12000) (T X W X L) Mm; 40 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Plt Bq 40 Mm (Sa516 Gr70) Tdc: Aa10403 + Ibr (Sl.No. 3.6.1 Of Aa10403) + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Bend Test( Sl. No. 5 Of Annexure-1 Of Aa10403)+ Simulation Heat Treatment (S5 + Sl.No.8 Of Annexure 1 Of Aa10403); No. Of Cycles Required In Sht: 01 Cycle For 3 Hrs Or 3 Cycles For 1 Hr.; 40 X 2500 X 9000 [T X W X L] [Mm]; 40 X 2500 X 9000 [T X W X L] [Mm] , Plate 40.0 Mm - A515gr70 + Ibr Requirement; 40 X 1000-2500 X 5000 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 40 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 40 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 40 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 42 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;42 Mm X 1800 Mm X 12000 Mm : T X W X L (Mm); 42 X 1800 X 12000 [T X W X L] [Mm] , Pl 45 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 45 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 45 Mm Is2062 E250 Gr Br.K Tdc 301 Rev 12;45 X 2500 X 6300-12000; ( T X W X L) Mm; 45 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 45 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;45 Mm X 1800 Mm X 12000 Mm : T X W X L (Mm); 45 X 1800 X 12000 [T X W X L] [Mm] , Pl 45 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 45 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 45 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 45 X W= 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 45 Mm Is 2062 E350b0 Tdc:6:386, Width 2500Mm, Length 12000Mm; 45 X 2500 X 12000 [T X W X L] [Mm] , Plate 45.0 Mm; Is2062e350grb0; Tdc:6:386:Rev:03: 45 X 2500 X (10000-12000) (T X W X L) Mm; 45 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 45 Mm Is2062 E350 Gr B0; Tdc:386; 45 (T) X 2000 (W) X (10000-12000) (L) [Mm]; 45 X 2000 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Plate 45.0 Mm - Sa515gr70; 45 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 45 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 45 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 45 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 48 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;48 Mm 1800 Mm 10500 Mm : T X W X L (Mm); 48 X 1800 X 10500 [T X W X L] [Mm] , Pl 50 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 50 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [Mm] , Pl 50 Mm Is2062 E250 Gr Br/K Tdc 301 Rev 12 + Ust As Per Astm A435; 50 X W = 3200 X L = 7000 [T X W X L] [Mm] , Pl 50 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;50 Mm X 1800 Mm X 12000 Mm : T X W X L (Mm); 50 X 1800 X 12000 [T X W X L] [Mm] , Pl 50 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 50 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pi 50 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 50 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 50 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 50 X W= 2500 X L= 12000 [T X W X L] [Mm] , Pl 50 Mm Is2062 E350 Gr B0; Tdc:386; 50 (T) X 2000 (W) X (10000-12000) (L) [Mm]; 50 X 2000 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Plate 50.0 Mm - Sa515gr70; 50 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 50 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 50 X 2500 X 6300 [T X W X L] [Mm] , Pl 50 Mm (Sa387 Gr12 Class 2 - Non Ibr); Tdc: Aa10647; 50 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [Mm]; 50 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [Mm] , Pl 52 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;52 Mm X 1800 Mm X 12000 Mm : T X W X L (Mm); 52 X 1800 X 12000 [T X W X L] [Mm] , Plate 55.0 Mm - Sa515gr70; 55 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 56 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 56 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 56 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 56 X 2500 X 12000 [T X W X L] [Mm] , Pi 56 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 56 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 56 Mm Is 2062 E350b0 Tdc:6:386, Width 2500Mm, Length 12000Mm; 56 X 2500 X 12000 [T X W X L] [Mm] , Plate 56 Mm; Is2062 E250gr Br; Tdc::301:Rev:12: 56 X 2500 X (10000-12000) (T X W X L) Mm; 56 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Plate 56 Mm; Is2062 E350gr Br; Tdc::301:Rev:12: 56 X 2500 X (10000-12000) (T X W X L) Mm; 56 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 56 Mm Is2062 E350 Gr B0; Tdc:386; 56 (T) X 2200 (W) X (10000-12000) (L) [Mm]; 56 X 2200 X (10000-12000) [T X W X L] [Mm] , Pl 56 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 56 Mm X 2500 Mm X 6500 Mm : T X W X L (Mm); 56 X 2500 X 6500 [T X W X L] [Mm] , Pi 60 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 60 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Plate 60.0 Mm - Sa515gr70; 60 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 63 Mm Is2062 E250 Gr A/Br/Sk/K Tdc 301 Rev 12; 63 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 63 Mm Is2062 E250 Gr Br/K Tdc 301, Width 2500Mm, Length 8000Mm; 63 X W=2500 X L =8000 [T X W X L] [Mm] , Pl 63 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;63 Mm X 2500 Mm X 9500 Mm : T X W X L (Mm); 63 X 2500 X 9500 [T X W X L] [Mm] , Pl 63 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 63 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 63 Mm Is 2062 E250br/K Tdc:6:386, Width 2500Mm, Length 12000Mm; 63 X 2500 X 12000 [T X W X L] [Mm] , Pl 63 Mm Is2062 E350 Gr B0; Tdc:386; 63 (T) X 2200 (W) X (10000-12000) (L) [Mm]; 63 X 2200 X (10000-12000) [T X W X L] [Mm] , Pl 63 Mm Is 2002 Grade-2; Tdc: Aa10401 Rev. 17 ; W = 3600 ; L= 7800;[Thickness, Length (L) & Width (W) Are In Mm]; 63 X 3600 X 7800 [T X W X L] [Mm] , Pl 63 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 63 Mm X 2500 Mm X 6500 Mm : T X W X L (Mm); 63 X 2500 X 6500 [T X W X L] [Mm] , Plate 63.0 Mm - Sa515gr70; 63 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 63 Mm Is2062 E250 Gr Br/K Tdc 301 Rev 12;Tdc:301 Rev 12; 63 X 2500 X [6300-12000] (T X W X L) Mm; 63 X 2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 70 Mm Is 2062 E 250 Gr Br/K Tdc 301, Width 2500Mm, Length 8000Mm; 70 X W=2500 X L =8000 [T X W X L] [Mm] , Pl 70 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;70 Mm X 2000 Mm X 8500 Mm : T X W X L (Mm); 70 X 2000 X 8500 [T X W X L] [Mm] , Pl 70 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 70 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 70 Mm Is 2002 Grade-2; Tdc: Aa10401 Rev. 17 ; W = 2500 ; L= 8000-10000 ;[Thickness, Length (L) & Width (W) Are In Mm]; 70 X 2500 X 8000 ≤ L ≤ 10000 [T X W X L] [Mm] , Plate 70.0 Mm - Sa515gr70; 70 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 75 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 75 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pi 75 Mm Is2062 E350 Gr B0 Tdc:6:386 Rev 03; 75 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 80 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B.;80 Mm X 2500 Mm X 7000 Mm : T X W X L (Mm; 80 X 2500 X 7000 [T X W X L] [Mm] , Pl 80 Mm Is 2062 E 350 Gr B0 Tdc:6:386 Rev 03; 80 X 2000≤ W ≤ 2500 X 6000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 80 Is 2062 E250gr-Br/K, Tdc:301, 80 X 2500 X 7650 [T X W X L] [Mm]; 80 X 2500 X 7650 [T X W X L] [Mm] , Pl 80 Mm Is2062 E250 Gr Br/K Tdc 301 + Ust As Per Astm A435; 80 (T) X 2500 (W) X 10000 (L) [Mm]; 80 X 2500 X 10000 [T X W X L] [Mm] , Pl 80 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 80 X 2850 X 10700 [T X W X L] [Mm]; 80 X 2850 X 10700 [T X W X L] [Mm] , Pl 80 Mm Is 2002 Grade-2; Tdc: Aa10401 Rev. 17 ; W = 2500 ; L= 8000-10000 ;[Thickness, Length (L) & Width (W) Are In Mm]; 80 X 2500 X 8000 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 80 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 80 Mm X 2500 Mm X 6500 Mm : T X W X L (Mm); 80 X 2500 X 6500 [T X W X L] [Mm] , Plate 80.0 Mm - Sa515gr70; 80 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [Mm] , Pl 85 Mm Is 2062 E 350 Gr B0 Tdc:6:386 Rev 03; 85 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 90 Mm Is 2062 E 250 Gr Br/K; Tdc:301; 90 X 3000 X 6300 ≤ L ≤ 12600 [T X W X L] [Mm] , Pl 90 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 90 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 90 Mm A516 Gr.70; Tdc: Aa10403 + Impact Test (S5 + Sl.No. 3 Of Annexure 1 Of Aa10403) + Ibr (Sl.No. 6 Of Annexure 1 Of Aa10403); 90 Mm X 2500 Mm X 6500 Mm : T X W X L (Mm); 90 X 2500 X 6500 [T X W X L] [Mm] , Pl 100 Mm Is 2062 E 250 Gr Br; 100 X 3000 X 6000 [T X W X L] [Mm] , Pl 100 Mm Is 2062 E250 Gr Br; 100 X 2500 X 6000 L 12000 [T X W X L] [Mm] , Pl 100 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Ut: Astm A 578 Level B.;100 Mm X 2500 Mm X 12000 Mm : T X W X L (Mm); 100 X 2500 X 12000 [T X W X L] [Mm] , Pl 100 Mm Is2062 E350 Gr C; Tdc:301 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Bend Test + Ut: Astm A 578 Level B + Through Thickness Tension Testing To Quality Class Z25 (As Per En10164); 100 (T) X 2500 (W) X 11000 (L) [Mm]; 100 X 2500 X 11000 [T X W X L] [Mm] , Pi 100 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 100 X W= 4400 X L= 4600 [T X W X L] [Mm] , Pl 100 Mm Is 2062 E 350 Gr B0 Tdc:6:386 Rev 03; 100 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 100 Mm Is2062 E250 Gr Br/K Tdc:6:386 Rev 03; 100 X 2500 X 6000 [T X W X L] [Mm]; 100 X 2500 X 6000 [T X W X L] [Mm] , Pl 100 Mm Is 2002 Grade-2; Tdc: Aa10401 Rev. 17 ; W = 2200 ; L= 4800;[Thickness, Length (L) & Width (W) Are In Mm]; 100 X 2200 X 4800 [T X W X L] [Mm] , Pl 100 Mm A516 Grade-70; Tdc : Aa10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 Of Annexure-1); 100 X 2200 X 10000 [T X W X L] [Mm] , Pl 110 Mm Is 2062 E 250 Gr A/Br/Sk/K; 110 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 110 Mm Is 2062 E 350 Gr B0 Tdc:6:386 Rev 03; 110 X 2000≤ W ≤ 2500 X 6000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 110 Mm Is2062 E350 Gr Br/K Tdc:301; 110 (T) X 2850 (W) X (6300-12000) (L) [Mm]; 110 X 2850 X 6300 ≤ L ≤ 12600 [T X W X L] [Mm] , Pl 110 Mm Is2062 E250 Gr Br./K Tdc:386; 110 (T) X 2500 (W) X 10000 (L) [Mm]; 110 X 2500 X 10000 [T X W X L] [Mm] , Pl 110 Mm Is 2002 Grade-2; Tdc: Aa10401 Rev. 17 ; W = 1650 ; L= 8000;[Thickness, Length (L) & Width (W) Are In Mm]; 110 X 1650 X 8000 [T X W X L] [Mm] , Pl 110 Mm A516 Grade-70; Tdc : Aa10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 2 & 3 Of Annexure-1); 110 X 2000≤ W ≤2500 X 6000 ≤ L ≤ 8000 [T X W X L] [Mm] , Pl 115 Mm Is 2062 E 250 Gr A/Br/Sk/K; 115 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 115 Mm A516 Grade-70; Tdc : Aa10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 Of Annexure-1) + Bend Test( Sl. No. 5 Of Annexure-1); 115 X W = 2500 X L = 10000 [T X W X L] [Mm] , Pl 120 Mm Is 2062 E 350 Gr B0 Tdc:6:386 Rev 03; 120 X 2000≤ W ≤ 2500 X 6000 ≤ L ≤ 12000 [T X W X L] [Mm] , Pl 120 Mm Is 2002 Grade-2; Tdc: Aa10401 Rev. 17 ; W = 2500 ; L= 10000;[Thickness, Length (L) & Width (W) Are In Mm]; 120 X 2500 X 10000 [T X W X L] [Mm] , Pl 130 Mm Is2062 E350 Gr C; Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Ut: Astm A 578 Level B.;130 Mm X 2500 Mm X 6000 Mm : T X W X L (Mm); 130 X 2500 X 6000 [T X W X L] [Mm] , Pl 130 Mm Is 2062 E 250 Gr Br/K Tdc:6:386 Rev 03; 130 X 1800 X 5600 [T X W X L] [Mm] , Pl 140 Mm Is 2002 Grade-2; Tdc: Aa10401 Rev. 17 ; W = 2000 ; L= 10500;[Thickness, Length (L) & Width (W) Are In Mm; 140 X 2000 X 10500 [T X W X L] [Mm] , Pl 190 Mm Is2062 E350 Gr C Tdc:301 Rev 12 + Charpy V-Notch Impact Test In Both Longitudinal & Transverse Specimen + Ut: Astm A435, 190 Mm X 2250 Mm X 6300 Mm T X W X L (Mm); 190 X 2250 X 6300 [T X W X L] [Mm]
BOQ
| Sl. No. | Item Description |
| 1 | CR COIL 0.63X700 IS 513 CR3 DD TDC:RTA:408:R04; 0.63 X 700 X Coil form [T X W X L] [mm] |
| 2 | CR COIL 0.63X813 X Coil Form; IS 513 DD; TDC:RTA:408; 0.63 X 813 X Coil form [T X W X L] [mm] |
| 3 | CR COIL 0.63X915 X Coil Form; IS 513 DD; TDC:RTA:408; 0.63 X 915 X Coil form [T X W X L] [mm] |
| 4 | GP Sheet 0.63 mm Class VIII IS 277; 0.63 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 5 | CR COIL 0.80X650 IS 513 CR3 DD TDC:RTA:408:R04; 0.8 X 650 X Coil form [T X W X L] [mm] |
| 6 | COLD ROLLED COIL 1.25 X 903 IS 513 GR.CR3 TDC:RTE:257 Rev:04; 1.25 X 903 X Coil form [T X W X L] [mm] |
| 7 | CR sheet 1.6 mm IS 513 CR2 - KLD; 1.6 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 8 | HR Sheets 1.6 mm IS 1079 Gr.HR2 SK/K; 1.6 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 9 | HR Sheet 2 mm IS 5986 Gr 205; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 10 | CR sheet 2.0 mm IS 513 CR2 - KLD; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 11 | CR sheet 2.0 mm IS 513 CR2 - KLD; 2 X 1250 X 2500 [T X W X L] [mm] |
| 12 | HR Sheets 2 mm IS 1079 Gr.HR1 SK/K; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 13 | HR Sheets 2 mm IS 1079 Gr.HR2 SK/K; 2 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 14 | HR Sheet 2.5 mm IS 5986 Gr 205; 2.5 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 15 | HR Sheets 2.5 mm IS 1079 Gr.HR2 SK/K; 2.5 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 16 | 3.0 MM X 1250 MM X 2500 MM CRC STEEL SHEETS ANNEALED TO SPECIFICATION AA 10115 REV-09 (IS 513 CR2 KLD); 3 X W=1250 X L=2500 [T X W X L] [mm] |
| 17 | HR Sheet 3.15 mm IS 5986 Gr 205; 3.15 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 18 | HR Sheets 3.15 mm IS 1079 Gr.HR1 SK/K; 3.15 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 19 | HR Sheets 3.15 mm IS 1079 Gr.HR2 SK/K; 3.15 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 20 | HR Sheet 4.0mm IS 5986 Gr 205; 4 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 21 | HR Sheets 4 mm IS 1079 Gr.HR2 SK/K; 4 X 900 ≤ W ≤ 1250 X L = 2500 [T X W X L] [mm] |
| 22 | Pl 4 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 4 (T) X 900/ 1200/ 1235/ 1500 (W) X 2500 (L) [mm]; 4 X 900/1200/1235/1500 X 2500 [T X W X L] [mm] |
| 23 | Pl 5 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 5 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [mm] |
| 24 | Pl 5 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 5 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [mm] |
| 25 | CQ Pl 5 mm IS 3502; 5 X 900 ≤ W ≤ 1250 X L ≤ 6300 [T X W X L] [mm] |
| 26 | Pl 5 mm IS2062 E250 Gr BR/K TDC:386; 5 (T) x 1500 ≤ W ≤ 1800 (W) x (6300-12000) (L) [mm]; 5 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 27 | Pl 5 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 5 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [mm]; 5 X 1200/1235/1500 X 6500 [T X W X L] [mm] |
| 28 | Pl 6 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 6 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [mm] |
| 29 | Pl 6 mm IS 2062 E 250 Gr A/BR/SK/K; 6 X W ≤ 1250 X L ≤ 6300 [T X W X L] [mm] |
| 30 | Pl 6 mm IS2062 E350 Gr B0/K TDC:301; 6 (T) x 1500 ≤ W ≤ 1800 (W) x (6300-12000) (L) [mm]; 6 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 31 | Pl 6 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 6 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [mm] |
| 32 | Pl 6 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 6 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 33 | CQ Pl 6 mm IS 3502; 6 X 900 ≤ W ≤ 1250 X L ≤ 6300 [T X W X L] [mm] |
| 34 | Pl 6 mm IS2062 E250 Gr BR/K ; TDC:301 ; 6 (T) x 1500 ≤ W ≤ 1800 (W) x (6300-12000) (L) [mm]; 6 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 35 | Pl 6 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 6 (T) x 2000 (W) x (6300-12000) (L) mm; 6 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 36 | Pl 6 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 6 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [mm]; 6 X 1200/1235/1500 X 6500 [T X W X L] [mm] |
| 37 | Pl 6 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 6 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [mm]; 6 X 1200/1235/1500 X 6500 [T X W X L] [mm] |
| 38 | Pl 7 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 7 X 1500 ≤ W ≤ 1800 X L ≤ 6300 [T X W X L] [mm] |
| 39 | Pl 8 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 8 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 40 | Pl 8 mm IS 2062 E 250 Gr A/BR/SK/K TDC:301 Rev 12; 8 X 2500 X L= 6300 [T X W X L] [mm] |
| 41 | Pl 8 mm IS2062 E350 Gr BR/K TDC 301 Rev12, width 2500 mm, length 9000 mm; 8 X 2500 X 9000 [T X W X L] [mm] |
| 42 | Pl 8 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 8 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 43 | Pl 8 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 8 X 2900 X 10000 [T X W X L] [mm] |
| 44 | Pl 8 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 8 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 45 | Pl 8 mm IS2062 E350 Gr B0/K TDC:386; 8 (T) x 2000 (W) x (6300-12000) (L) [mm]; 8 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 46 | Pl 8 mm IS2062 E350 Gr B0/K TDC:386; 8 (T) x 2500 (W) x (6300-12000) (L) [mm]; 8 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 47 | CQ Pl 8 mm IS 3502; 8 X 900 ≤ W ≤1250 X L ≤ 6300 [T X W X L] [mm] |
| 48 | Pl 8 mm IS2062 E250 Gr BR/K TDC:301; 8 (T) x 2000 (W) x (6300-12000) (L) [mm]; 8 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 49 | Pl 8 mm IS2062 E250 Gr BR/K TDC:386; 8 (T) x 2500 (W) x (6300-12000) (L) [mm]; 8 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 50 | Pl 8 mm IS 2062 E250Br/K TDC:6:386,; 8 X 2500 X 12000 [T X W X L] [mm] |
| 51 | PLATE 8.00 MM - SA515GR70; 8 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 52 | Pl 8 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 8 (T) X 1200/ 1235/ 1500 (W) X 7500 (L) [mm]; 8 X 1200/1235/1500 X 7500 [T X W X L] [mm] |
| 53 | Pl 8 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 8 (T) X 1200/ 1235/ 1500 (W) X 6500 (L) [mm]; 8 X 1200/1235/1500 X 7500 [T X W X L] [mm] |
| 54 | Pl 10 mm IS2062 E350 Gr BR/K TDC:386; 10 (T) x 2000 (W) x (6300-12000) (L) [mm]; 10 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 55 | Pl 10 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 10 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [mm] |
| 56 | Pl 10 mm IS 2062 E 250 Gr A/BR/SK/K TDC:301 Rev 12; 10 X 2500 X L= 6300 [T X W X L] [mm] |
| 57 | Pl 10 mm IS 2062 E250Br/K TDC 301 , width 2000mm, length 12000 mm; 10 X 2000 X 12000 [T X W X L] [mm] |
| 58 | Pl 10 mm IS2062 E350 Gr B0/K TDC:301; 10 (T) x 2500 (W) x (6300-12000) (L); 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 59 | Pl 10 mm IS2062 E350 Gr B0/K TDC:301; 10 (T) x 2000 (W) x (6300-12000) (L); 10 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 60 | Pl 10 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 10 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 61 | Pl 10 mm IS 2062 E250Br/K TDC:6:386, width 2500mm, length 10000mm; 10 X 2500 X 10000 [T X W X L] [mm] |
| 62 | Pl 10 mm IS2062 E350 Gr B0/K TDC:386; 10 (T) x 2500 (W) x (6300-12000) (L) [mm]; 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 63 | CQ Pl 10 mm IS 3502; 10 X 900 ≤ W ≤1250 X L ≤ 6300 [T X W X L] [mm] |
| 64 | Pl 10 mm IS2062 E250 Gr BR/K TDC:301; 10 (T) x 2500 (W) x (6300-12000) (L) [mm]; 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 65 | Pl 10 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 10 (T) x 2000 (W) x (6300-12000) (L) mm; 10 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 66 | Pl 10 mm IS2062 E250 Gr BR/K TDC:386; 10 (T) x 2500 (W) x (6300-12000) (L) [mm]; 10 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 67 | Pl 10 mm IS2062 E250 Gr Br./K; TDC:386 + Normalizing Rolling; 10 (T) x 2500 (W) x 12500 (L) [mm]; 10 X 2500 X 12500 [T X W X L] [mm] |
| 68 | PL 10 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 10 x 2500 x 6500 [T x W x L] [mm]; 10 X 2500 X 6500 [T X W X L] [mm] |
| 69 | PLATE 10.0 MM - SA515GR70; 10 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 70 | Pl 10 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 10 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 10 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 71 | Pl 10 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 10 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 10 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 72 | Pl 12 mm IS2062 E350 Gr BR/K TDC:386; 12 (T) x 2500 (W) x (6300-12000) (L) [mm; 12 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 73 | Pl 12 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 12 X W= 2500 X 1000 ≤ L ≤ 12500 [T X W X L] [mm] |
| 74 | Pl 12 mm IS 2062 E 250 Gr A/BR/SK/K TDC:301 Rev 12; 12 X 2500 X L= 6300 [T X W X L] [mm] |
| 75 | Pl 12 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 12 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 76 | Pl 12 mm IS 2062 E250Br/K TDC:6:386, width 2500mm, length 12000mm; 12 X 2500 X 12000 [T X W X L] [mm] |
| 77 | PI 12 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 12 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 78 | Pl 12 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 12 (T) x 2000 (W) x (6300-12000) (L) mm; 12 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 79 | Pl 12 mm IS2062 E250 Gr BR/K TDC:386; 12 (T) x 2500 (W) x (6300-12000) (L) [mm]; 12 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 80 | Pl 12 mm IS2062 E250 Gr Br./K; TDC:386 + Normalizing Rolling; 12 (T) x 2500 (W) x 10000 (L) [mm]; 12 X 2500 X 10000 [T X W X L] [mm] |
| 81 | Pl 12 mm IS2062 E350 Gr B0/K TDC:386; 12 (T) x 2500 (W) x (6300-12000) (L) [mm]; 12 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 82 | PL 12MM A516 GR. 70; TDC: AA10403 REV 01 + SUPPLEMENTRY RQUIREMENTS: IMPACT TEST (S5 + SL. NO. 1 & 2 OF ANNEXURE- 1)+BEND TEST (SL. NO. 5 OF ANNEXURE-1) .; 12 X 3000 X 8000< L < 12000 [T X W X L] [mm] |
| 83 | PLATE 12.0 MM - SA515GR70; 12 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 84 | Pl 12 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 12 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 12 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 85 | Pl 12 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 12 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 12 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 86 | Pl 12.7 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 12.7 X 3750 X 5850 [T X W X L] [mm] |
| 87 | PL 14 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 14 mm x 2500 mm x 6500 mm : T X W X L (mm); 14 X 2500 X 6500 [T X W X L] [mm] |
| 88 | PLT BQ 14 MM (SA516 GR70) TDC: AA10403 + IBR (sl.no. 3.6.1 of AA10403)+Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) +Bend Test( Sl. No. 5 of Annexure-1 of AA10403); 14 X 2000 X 8000 [T X W X L] [mm]; 14 X 2000 X 8000 [T X W X L] [mm] |
| 89 | Pl 16 mm IS2062 E250 Gr BR/K TDC 301 Rev 12; 16 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [mm] |
| 90 | Pl 16 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 16 X 1500 ≤ W ≤ 1800 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 91 | Pl 16 mm IS 2062 E250Br/K TDC:6:386, width 2500mm, length 12000mm; 16 X 2500 X 12000 [T X W X L] [mm] |
| 92 | Pl 16 mm IS2062 E250 Gr BR/K TDC:301; 16 (T) x 2000 (W) x (6300-12000) (L) [mm]; 16 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 93 | Pl 16 mm IS2062 E250 Gr BR/K ;TDC 301 Rev 12; (Impact test at room temperature is mandatory); UT as per ASTM A435: 16 x 2500 x 6300 ; T (mm) x W (mm) x L (mm); 16 X 2500 X L= 6300 [T X W X L] [mm] |
| 94 | Pl 16 mm IS2062 E350 Gr BR/K TDC:301; 16 (T) x 2500 (W) x (6300-12000) (L) [mm]; 16 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 95 | Pl 16 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 16 (T) x 2500 (W) x (6300-12000) (L) mm; 16 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 96 | Pl 16 mm IS 2062 E250 Gr BR_TDC:6:386 Rev 03; 16 X 3400 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 97 | Pl 16 mm IS2062 E250 Gr BR/K; TDC:386 + Normalising + UST as per ASTM A578 Level B, 16 (T) X 2500 (W) X 12500 (L) [mm]; 16 X 2500 X 12500 [T X W X L] [mm] |
| 98 | Pl 16 mm IS2062 E350 Gr B0/K TDC:386; 16 (T) x 2500 (W) x (6300-12000) (L) [mm]; 16 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 99 | PL 16 MM A516 GRADE-70- Supplementary Requirements: Impact Test (S5 + Sl. No. 2 & 3 of Annexure-1); 16 X 2000≤ W ≤2500 X 8000 ≤ L ≤12500 [T X W X L] [mm] |
| 100 | PL 16 MM A516 GRADE-70; TDC : AA10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 of Annexure-1) + Bend Test( Sl. No. 5 of Annexure-1); 16 x 2500 x 5700 [T X W X L] [mm]; 16 X 2500 X 5700 [T X W X L] [mm] |
| 101 | PL 16 MM A516 GRADE-70; TDC : AA10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 of Annexure-1) + Bend Test( Sl. No. 5 of Annexure-1); 16 X 2500 X 7500 [T X W X L] [mm] |
| 102 | PL 16 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 16 X 2500 X 6300 [T X W X L] [mm] |
| 103 | PLT BQ 16 MM (SA516 GR 70) TDC: AA10403 + IBR (sl.no. 3.6.1 of AA10403)+Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + Bend Test( Sl. No. 5 of Annexure-1 of AA10403); 16 X 2000 X 10000 [T X W X L] [mm; 16 X 2000 X 10000 [T X W X L] [mm] |
| 104 | PLT BQ 16 MM (SA516 GR 70) TDC: AA10403 + IBR (sl.no. 3.6.1 of AA10403)+Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + Bend Test( Sl. No. 5 of Annexure-1 of AA10403); 16 X 2500 X (6300 ≤ L ≤ 10000) [T X W X L] [mm]; 16 X 2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 105 | Pl 16 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 16 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 16 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 106 | Pl 16 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 16 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 16 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 107 | Pl 18 mm IS2062 E350 Gr BR/K TDC:301; 18 (T) x 2500 (W) x (6300-12000) (L) [mm]; 18 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 108 | Pl 20 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 20 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [mm] |
| 109 | PLATE-20 IS2062 E250BR TDC:301 Rev 12; 20 X 2500 X 7925 [T X W X L] [mm] |
| 110 | PI 20 mm IS2062 E350 Gr BR TDC 301 Rev 12; 20 X W= 2500 X L = 12000 [T X W X L] [mm] |
| 111 | PLATE 20.0 MM; IS2062E350 GR B0; TDC:6:386:REV:03: 20 x 2500 x (10000-12000) (T x W x L) mm; 20 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 112 | Pl 20 mm IS2062 E250 Gr BR/K ;TDC 301 Rev 12; (Impact test at room temperature is mandatory); UT as per ASTM A435: 20 x 2500 x 6300 ; T (mm) x W (mm) x L (mm); 20 X 2500 X L= 6300 [T X W X L] [mm] |
| 113 | Pl 20 mm IS2062 E250 Gr BR/K TDC:301; 20 (T) x 2000 (W) x (6300-12000) (L) [mm]; 20 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 114 | Pl 20 mm IS2062 E250 Gr. Br; TDC 301; 20 (T) x 2500 (W) x 11425 (L) [mm]; 20 X 2500 X 11425 [T X W X L] [mm] |
| 115 | Pl 20 mm IS2062 E350 Gr BR/K TDC:301; 20 (T) x 2000 (W) x (6300-12000) (L) [mm]; 20 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 116 | Pl 20 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 20 (T) x 2000 (W) x (6300-12000) (L) mm; 20 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 117 | Pl 20 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 20 (T) x 2500 (W) x (6300-12000) (L) mm; 20 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 118 | Pl 20 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 20 x 2500 x 7100 [T X W X L] [mm]; 20 X 2500 X 7100 [T X W X L] [mm] |
| 119 | Pl 20 mm IS2062 E250 Gr BR/K; TDC:386 + Normalising + UST as per ASTM A578 Level B, 20 (T) X 2500 (W) X 12500 (L) [mm]; 20 X 2500 X 12500 [T X W X L] [mm] |
| 120 | Pl 20 mm IS2062 E350 Gr B0/K TDC:386; 20 (T) x 2500 (W) x (6300-12000) (L) [mm]; 20 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 121 | Pl 20 mm IS2062 E350 Gr B0; TDC:386; 20 (T) x 2200 (W) x (10000-12000) (L) [mm]; 20 X 2200 X (10000-12000) [T X W X L] [mm] |
| 122 | PLATE 20.0 MM - SA515GR70; 20 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 123 | PL 20 MM A516 GRADE-70; TDC : AA10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 of Annexure-1) + Bend Test( Sl. No. 5 of Annexure-1); 20 X 2500 X 6300 [T X W X L] [mm] |
| 124 | Pl 20 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 20 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 20 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 125 | Pl 20 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 20 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 20 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 126 | PL 22 MM A515 GRADE-70; AA10404; 22 X 3000 X 10000 [T X W X L] [mm] |
| 127 | Pl 25 mm IS2062 E350 Gr BR/K TDC:386; 25 (T) x 2500 (W) x (6300-12000) (L) [mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 128 | Pl 25 mm IS2062 E250 Gr BR/K TDC 301 Rev 12; 25 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [mm] |
| 129 | Pl 25 mm IS2062 E350 Gr BR/K TDC:301; 25 (T) x 2500 (W) x (6300-12000) (L) [mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 130 | Pl 25 mm IS2062 E350 Gr BR/K TDC:301; 25 (T) x 2000 (W) x (6300-12000) (L) [mm]; 25 X 2000 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 131 | Pl 25 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 25 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 132 | PI 25 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 25 X W= 2500 X L= 12000 [T X W X L] [mm] |
| 133 | Pl 25 mm IS2062 E250 Gr BR/K ;TDC 301 Rev 12; (Impact test at room temperature is mandatory); UT as per ASTM A435: 25 x 2500 x 6300 ; T (mm) x W (mm) x L (mm); 25 X 2500 X L= 6300 [T X W X L] [mm] |
| 134 | Pl 25 mm IS2062 E250 Gr BR/K TDC:301 Rev 03; 25 (T) x 2500 (W) x (6300-12000) (L) [mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 135 | Pl 25 mm IS2062 E250 Gr BR/K; TDC 301 + UST as per ASTM A435, 25 (T) X 2500 (W) X 12500 (L) [mm]; 25 X 2500 X 12500 [T X W X L] [mm] |
| 136 | PL.25 x 2500 x 12000 is 2062 E250 Gr. Br. TDC 6 386 Rev.03; 25 X 2500 X 12000 [T X W X L] [mm] |
| 137 | Pl 25 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 25 (T) x 2500 (W) x (6300-12000) (L) mm; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 138 | Pl 25 mm IS2062 E350 Gr B0/K TDC:386; 25 (T) x 2500 (W) x (6300-12000) (L) [mm]; 25 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 139 | PLATE 25.0 MM - SA515GR70; 25 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 140 | PL 25 MM SA515 GRADE-70 AA10404-05 + Supplementary requirements: Charpy-V-test (longitudinal / transverse sample) shall be performed getting values of KV 27 J at -20°C or KV 34 J at 0°C or KV 40 J at 20°C “.; 25 X 3100 X 6700 [T X W X L] [mm] |
| 141 | PLT BQ 25 MM (SA516 GR70) TDC: AA10403 +IBR (sl.no. 3.6.1 of AA10403) + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + Bend Test( Sl. No. 5 of Annexure-1 of AA10403)+ SIMULATION HEAT TREATMENT (S5 + sl.no.8 of Annexure 1 of AA10403); No. of cycles required in SHT: 01 cycle for 3 hrs or 3 cycles for 1 hr.; 25 x 2500 x 13000 [T X W X L] [mm]; 25 X 2500 X 13000 [T X W X L] [mm] |
| 142 | Pl BQ 25 MM (SA516 GR70) TDC: AA10403 +IBR (sl.no. 3.6.1 of AA10403) + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + Bend Test (Sl. No. 5 of Annexure-1 of AA10403) + SIMULATION HEAT TREATMENT (S5 + sl.no.8 of Annexure 1 of AA10403); No. of cycles required in SHT: 01 cycle for 3 hrs or 3 cycles for 1 hr.; 25 X 2500 X 10000 [T X W X L] [mm]; 25 X 2500 X 10000 [T X W X L] [mm] |
| 143 | Pl 25 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 25 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 25 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 144 | Pl 25 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 25 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [mm]; 25 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [mm] |
| 145 | Pl 28 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 28 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 146 | Pl 28 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 28 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 147 | Pl 28 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 28 X W= 2500 X L= 12000 [T X W X L] [mm] |
| 148 | Pl 28 mm IS2062 E250 Gr BR/K ;TDC 301 Rev 12; (Impact test at room temperature is mandatory); UT as per ASTM A435: 28 x 2500 x 6300 ; T (mm) x W (mm) x L (mm); 28 X 2500 X L= 6300 [T X W X L] [mm] |
| 149 | Pl 28 mm IS2062 E350 Gr B0; TDC:386; 28 (T) x 2200 (W) x (10000-12000) (L) [mm]; 28 X 2200 X (10000-12000) [T X W X L] [mm] |
| 150 | PLT BQ 28 MM (SA516 GR70) TDC: AA10403 + IBR (sl.no. 3.6.1 of AA10403) + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + Bend Test( Sl. No. 5 of Annexure-1 of AA10403)+ SIMULATION HEAT TREATMENT (S5 + sl.no.8 of Annexure 1 of AA10403); No. of cycles required in SHT: 01 cycle for 3 hrs or 3 cycles for 1 hr.; 28 x 2500 x 13000 [T X W X L] [mm]; 28 X 2500 X 13000 [T X W X L] [mm] |
| 151 | Pl 30 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;30 mm X 1500 mm X 8000 mm : T X W X L (mm); 30 X 1500 X 8000 [T X W X L] [mm] |
| 152 | PI 30 mm IS2062 E250 GR BR TDC:6:386 Rev 03; 30 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 153 | PLATE 30.0 MM - SA515GR70; 30 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 154 | PL 30 MM SA515 GRADE-70 AA10404-05 + Supplementary requirements: Impact test at room temperature+orientation of the test specimen in longitudinal direction(S5); 30 X 4000 X 6750 [T X W X L] [mm] |
| 155 | Pl 30 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 30 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [mm]; 30 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [mm] |
| 156 | Pl 32 mm IS2062 E250 Gr A/BR/SK/K TDC:6:386 Rev 03; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 10000 [T X W X L] [mm] |
| 157 | Pl 32 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 32 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [mm] |
| 158 | Pl 32 mm IS2062 E250 Gr BR/K TDC 301 Rev 12 + UST as per ASTM A435,width 2500 mm, length 12500 mm; 32 X W = 2500 X L = 12500 [T X W X L] [mm] |
| 159 | PI 32 mm IS2062 E350 Gr BR TDC 301 Rev 12; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 160 | Pl 32 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 161 | PI 32 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 32 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 162 | PI 32 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 32 X W= 2500 X L= 12000 [T X W X L] [mm] |
| 163 | Pl 32 mm IS2062 E250 Gr BR/K ;TDC 301 Rev 12; (Impact test at room temperature is mandatory); UT as per ASTM A435: 32 x 2500 x 6300 ; T (mm) x W (mm) x L (mm); 32 X 2500 X L= 6300 [T X W X L] [mm] |
| 164 | Pl 32 mm IS2062 E250 Gr. Br/K TDC 301; 32 (T) x 2500 (W) x 7500 (L) [mm]; 32 X 2500 X 7500 [T X W X L] [mm] |
| 165 | PLATE 32.0 MM - SA515GR70; 32 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 166 | PL 32 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 32 X 2500 X 6300 ≤ L ≤ 10500 [T X W X L] [mm] |
| 167 | Pl BQ 32MM (SA516 GR70) TDC: AA10403 + IBR (sl.no. 3.6.1 of AA10403) + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + Bend Test (Sl. No. 5 of Annexure-1 of AA10403) + SIMULATION HEAT TREATMENT (S5 + sl.no.8 of Annexure 1 of AA10403); No. of cycles required in SHT: 01 cycle for 3 hrs or 3 cycles for 1 hr.; 32 X 2500 X 10000 [T X W X L] [mm]; 32 X 2500 X 10000 [T X W X L] [mm] |
| 168 | Pl 32 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 32 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 32 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 169 | Pl 32 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 32 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [mm]; 32 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [mm] |
| 170 | PI 34 mm IS2062 E350 Gr BR TDC 301 Rev 12; 34 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 171 | Pl 34 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 34 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 172 | Pl 35 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;35 mm X 1500 mm X 8000 mm : T X W X L (mm); 35 X 1500 X 8000 [T X W X L] [mm] |
| 173 | PLATE 35.0 MM - SA515GR70; 35 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 174 | Pl 36 mm IS2062 E250 Gr BR/K TDC 301 + UST as per ASTM A435, width 2500mm, length 12500mm; 36 X W=2500 X L =12500 [T X W X L] [mm] |
| 175 | PI 36 mm IS2062 E350 Gr BR/K TDC 301 Rev 12; 36 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 176 | Pl 36 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 36 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 177 | Pl 36 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 36 X 4500 X 8500 [T X W X L] [mm] |
| 178 | Pl 36 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 36 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 179 | Pl 36 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 36 X W= 2500 X L= 12000 [T X W X L] [mm] |
| 180 | Pl 36 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 36 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 36 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 181 | Pl 36 mm (SA387 GR22 Class 2 - Non IBR); TDC: AA10648; 36 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 9000/ 10000 (L) [mm]; 36 X 1200/1235/1500/2000/2500 X 6000/9000/10000 [T X W X L] [mm] |
| 182 | PLATE 38 MM; IS2062 E350GR Br; TDC::301:REV:12: 38 x 2500 x (10000-12000) (T x W x L) mm; 38 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 183 | Pl 40 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 184 | Pl 40 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 40 X W=3200 X L=6300 [T X W X L] [mm] |
| 185 | PI 40 mm IS2062 E350 Gr BR TDC 301 Rev 12; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 186 | Pl 40 mm IS2062 E350 Gr BR/K TDC 301 Rev12 + UST as per standard EN 10160, Class S2/E2, width 3200 mm, length 8000 mm; 40 X 3200 X 8000 [T X W X L] [mm] |
| 187 | Pl 40 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;40 mm X 2500 mm X 7500 mm : T X W X L (mm); 40 X 2500 X 7500 [T X W X L] [mm] |
| 188 | Pl 40 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 40 X W= 3800 X L= 5700 [T X W X L] [mm] |
| 189 | Pl 40 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 190 | Pl 40 mm IS 2062 E250Br/K TDC:6:386, width 2500mm, length 12000mm; 40 X 2500 X 12000 [T X W X L] [mm] |
| 191 | Pl 40 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 40 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 192 | Pl 40 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 40 X W= 2500 X L= 12000 [T X W X L] [mm] |
| 193 | PLATE 40.0 MM; IS2062E350GRB0; TDC:6:386:REV:03: 40 x 2500 x (10000-12000) (T x W x L) mm; 40 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 194 | Pl 40 mm IS2062 E250 Gr BR/K; TDC 301 Rev 12 + UST as per ASTM A435, 40 (T) X 3200 (W) X 6300 (L) [mm]; 40 X 3200 X 6300 [T X W X L] [mm] |
| 195 | PLATE 40 MM; IS2062 E350GR Br; TDC::301:REV:12: 40 x 2500 x (10000-12000) (T x W x L) mm; 40 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 196 | PLATE 40 MM; IS2062 E250GRBr; TDC:6:386:REV:03: 40 x 2500 x (10000-12000) (T x W x L) mm; 40 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 197 | PLT BQ 40 MM (SA516 GR70) TDC: AA10403 + IBR (sl.no. 3.6.1 of AA10403) + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + Bend Test( Sl. No. 5 of Annexure-1 of AA10403)+ SIMULATION HEAT TREATMENT (S5 + sl.no.8 of Annexure 1 of AA10403); No. of cycles required in SHT: 01 cycle for 3 hrs or 3 cycles for 1 hr.; 40 x 2500 x 9000 [T X W X L] [mm]; 40 X 2500 X 9000 [T X W X L] [mm] |
| 198 | PLATE 40.0 MM - A515GR70 + IBR requirement; 40 X 1000-2500 X 5000 ≤ L ≤ 10000 [T X W X L] [mm] |
| 199 | Pl 40 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 40 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 40 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 200 | Pl 42 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;42 mm X 1800 mm X 12000 mm : T X W X L (mm); 42 X 1800 X 12000 [T X W X L] [mm] |
| 201 | Pl 45 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 45 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 202 | Pl 45 mm IS2062 E250 Gr Br.K TDC 301 Rev 12;45 x 2500 x 6300-12000; ( T x W x L) mm; 45 X 2500 X 6300 ≤ L ≤ 12000 [T X W X L] [mm] |
| 203 | Pl 45 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;45 mm X 1800 mm X 12000 mm : T X W X L (mm); 45 X 1800 X 12000 [T X W X L] [mm] |
| 204 | Pl 45 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 45 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 205 | Pl 45 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 45 X W= 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 206 | Pl 45 mm IS 2062 E350B0 TDC:6:386, width 2500mm, length 12000mm; 45 X 2500 X 12000 [T X W X L] [mm] |
| 207 | PLATE 45.0 MM; IS2062E350GRB0; TDC:6:386:REV:03: 45 x 2500 x (10000-12000) (T x W x L) mm; 45 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 208 | Pl 45 mm IS2062 E350 GR B0; TDC:386; 45 (T) x 2000 (W) x (10000-12000) (L) [mm]; 45 X 2000 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 209 | PLATE 45.0 MM - SA515GR70; 45 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 210 | Pl 45 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 45 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 45 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 211 | Pl 48 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;48 mm 1800 mm 10500 mm : T X W X L (mm); 48 X 1800 X 10500 [T X W X L] [mm] |
| 212 | Pl 50 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 50 X W= 2500 X 10000 ≤ L ≤ 12500 [T X W X L] [mm] |
| 213 | Pl 50 mm IS2062 E250 Gr BR/K TDC 301 Rev 12 + UST as per ASTM A435; 50 X W = 3200 X L = 7000 [T X W X L] [mm] |
| 214 | Pl 50 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;50 mm X 1800 mm X 12000 mm : T X W X L (mm); 50 X 1800 X 12000 [T X W X L] [mm] |
| 215 | Pl 50 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 50 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 216 | PI 50 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 50 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 217 | Pl 50 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 50 X W= 2500 X L= 12000 [T X W X L] [mm] |
| 218 | Pl 50 mm IS2062 E350 GR B0; TDC:386; 50 (T) x 2000 (W) x (10000-12000) (L) [mm]; 50 X 2000 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 219 | PLATE 50.0 MM - SA515GR70; 50 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 220 | PL 50 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 50 X 2500 X 6300 [T X W X L] [mm] |
| 221 | Pl 50 mm (SA387 GR12 Class 2 - Non IBR); TDC: AA10647; 50 (T) X 1200/ 1235/ 1500/ 2000/ 2500 (W) X 6000/ 7500/ 9000/ 10000 (L) [mm]; 50 X 1200/1235/1500/2000/2500 X 6000/7500/9000/10000 [T X W X L] [mm] |
| 222 | Pl 52 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;52 mm X 1800 mm X 12000 mm : T X W X L (mm); 52 X 1800 X 12000 [T X W X L] [mm] |
| 223 | PLATE 55.0 MM - SA515GR70; 55 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 224 | Pl 56 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 56 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 225 | Pl 56 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 56 X 2500 X 12000 [T X W X L] [mm] |
| 226 | PI 56 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 56 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 227 | Pl 56 mm IS 2062 E350B0 TDC:6:386, width 2500mm, length 12000mm; 56 X 2500 X 12000 [T X W X L] [mm] |
| 228 | PLATE 56 MM; IS2062 E250GR Br; TDC::301:REV:12: 56 x 2500 x (10000-12000) (T x W x L) mm; 56 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 229 | PLATE 56 MM; IS2062 E350GR Br; TDC::301:REV:12: 56 x 2500 x (10000-12000) (T x W x L) mm; 56 X 2500 X 10000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 230 | Pl 56 mm IS2062 E350 Gr B0; TDC:386; 56 (T) x 2200 (W) x (10000-12000) (L) [mm]; 56 X 2200 X (10000-12000) [T X W X L] [mm] |
| 231 | PL 56 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 56 mm x 2500 mm x 6500 mm : T X W X L (mm); 56 X 2500 X 6500 [T X W X L] [mm] |
| 232 | PI 60 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 60 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 233 | PLATE 60.0 MM - SA515GR70; 60 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 234 | Pl 63 mm IS2062 E250 Gr A/BR/SK/K TDC 301 Rev 12; 63 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 235 | Pl 63 mm IS2062 E250 Gr BR/K TDC 301, width 2500mm, length 8000mm; 63 X W=2500 X L =8000 [T X W X L] [mm] |
| 236 | Pl 63 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;63 mm X 2500 mm X 9500 mm : T X W X L (mm); 63 X 2500 X 9500 [T X W X L] [mm] |
| 237 | Pl 63 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 63 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 238 | Pl 63 mm IS 2062 E250Br/K TDC:6:386, width 2500mm, length 12000mm; 63 X 2500 X 12000 [T X W X L] [mm] |
| 239 | Pl 63 mm IS2062 E350 Gr B0; TDC:386; 63 (T) x 2200 (W) x (10000-12000) (L) [mm]; 63 X 2200 X (10000-12000) [T X W X L] [mm] |
| 240 | PL 63 mm IS 2002 GRADE-2; TDC: AA10401 Rev. 17 ; W = 3600 ; L= 7800;[Thickness, Length (L) & Width (W) are in mm]; 63 X 3600 X 7800 [T X W X L] [mm] |
| 241 | PL 63 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 63 mm x 2500 mm x 6500 mm : T X W X L (mm); 63 X 2500 X 6500 [T X W X L] [mm] |
| 242 | PLATE 63.0 MM - SA515GR70; 63 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 243 | Pl 63 mm IS2062 E250 Gr BR/K TDC 301 Rev 12;TDC:301 Rev 12; 63 x 2500 x [6300-12000] (T x W x L) mm; 63 X 2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 244 | Pl 70 mm IS 2062 E 250 Gr BR/K TDC 301, width 2500mm, length 8000mm; 70 X W=2500 X L =8000 [T X W X L] [mm] |
| 245 | Pl 70 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;70 mm X 2000 mm X 8500 mm : T X W X L (mm); 70 X 2000 X 8500 [T X W X L] [mm] |
| 246 | Pl 70 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 70 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 247 | PL 70 mm IS 2002 GRADE-2; TDC: AA10401 Rev. 17 ; W = 2500 ; L= 8000-10000 ;[Thickness, Length (L) & Width (W) are in mm]; 70 X 2500 X 8000 ≤ L ≤ 10000 [T X W X L] [mm] |
| 248 | PLATE 70.0 MM - SA515GR70; 70 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 249 | Pl 75 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 75 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 250 | PI 75 mm IS2062 E350 Gr B0 TDC:6:386 Rev 03; 75 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 251 | Pl 80 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B.;80 mm X 2500 mm X 7000 mm : T X W X L (mm; 80 X 2500 X 7000 [T X W X L] [mm] |
| 252 | Pl 80 mm IS 2062 E 350 Gr B0 TDC:6:386 Rev 03; 80 X 2000≤ W ≤ 2500 X 6000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 253 | PL 80 IS 2062 E250GR-BR/K, TDC:301, 80 X 2500 X 7650 [T X W X L] [mm]; 80 X 2500 X 7650 [T X W X L] [mm] |
| 254 | Pl 80 mm IS2062 E250 Gr BR/K TDC 301 + UST as per ASTM A435; 80 (T) X 2500 (W) X 10000 (L) [mm]; 80 X 2500 X 10000 [T X W X L] [mm] |
| 255 | Pl 80 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 80 x 2850 x 10700 [T X W X L] [mm]; 80 X 2850 X 10700 [T X W X L] [mm] |
| 256 | PL 80 mm IS 2002 GRADE-2; TDC: AA10401 Rev. 17 ; W = 2500 ; L= 8000-10000 ;[Thickness, Length (L) & Width (W) are in mm]; 80 X 2500 X 8000 ≤ L ≤ 10000 [T X W X L] [mm] |
| 257 | PL 80 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 80 mm x 2500 mm x 6500 mm : T X W X L (mm); 80 X 2500 X 6500 [T X W X L] [mm] |
| 258 | PLATE 80.0 MM - SA515GR70; 80 X 2000-2500 X 6300 ≤ L ≤ 10000 [T X W X L] [mm] |
| 259 | Pl 85 mm IS 2062 E 350 Gr B0 TDC:6:386 Rev 03; 85 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 260 | Pl 90 mm IS 2062 E 250 Gr BR/K; TDC:301; 90 X 3000 X 6300 ≤ L ≤ 12600 [T X W X L] [mm] |
| 261 | Pl 90 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 90 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 262 | PL 90 mm A516 Gr.70; TDC: AA10403 + Impact test (S5 + sl.no. 3 of Annexure 1 of AA10403) + IBR (sl.no. 6 of Annexure 1 of AA10403); 90 mm x 2500 mm x 6500 mm : T X W X L (mm); 90 X 2500 X 6500 [T X W X L] [mm] |
| 263 | Pl 100 mm IS 2062 E 250 Gr BR; 100 X 3000 X 6000 [T X W X L] [mm] |
| 264 | Pl 100 mm IS 2062 E250 Gr BR; 100 X 2500 X 6000< L < 12000 [T X W X L] [mm] |
| 265 | Pl 100 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + UT: ASTM A 578 Level B.;100 mm X 2500 mm X 12000 mm : T X W X L (mm); 100 X 2500 X 12000 [T X W X L] [mm] |
| 266 | Pl 100 mm IS2062 E350 Gr C; TDC:301 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + Bend Test + UT: ASTM A 578 Level B + Through thickness tension testing to Quality class Z25 (as per EN10164); 100 (T) X 2500 (W) X 11000 (L) [mm]; 100 X 2500 X 11000 [T X W X L] [mm] |
| 267 | PI 100 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 100 X W= 4400 X L= 4600 [T X W X L] [mm] |
| 268 | Pl 100 mm IS 2062 E 350 Gr B0 TDC:6:386 Rev 03; 100 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 269 | Pl 100 mm IS2062 E250 Gr BR/K TDC:6:386 Rev 03; 100 x 2500 x 6000 [T X W X L] [mm]; 100 X 2500 X 6000 [T X W X L] [mm] |
| 270 | PL 100 mm IS 2002 GRADE-2; TDC: AA10401 Rev. 17 ; W = 2200 ; L= 4800;[Thickness, Length (L) & Width (W) are in mm]; 100 X 2200 X 4800 [T X W X L] [mm] |
| 271 | PL 100 MM A516 GRADE-70; TDC : AA10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 of Annexure-1); 100 X 2200 X 10000 [T X W X L] [mm] |
| 272 | Pl 110 mm IS 2062 E 250 Gr A/BR/SK/K; 110 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 273 | Pl 110 mm IS 2062 E 350 Gr B0 TDC:6:386 Rev 03; 110 X 2000≤ W ≤ 2500 X 6000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 274 | Pl 110 mm IS2062 E350 Gr BR/K TDC:301; 110 (T) x 2850 (W) x (6300-12000) (L) [mm]; 110 X 2850 X 6300 ≤ L ≤ 12600 [T X W X L] [mm] |
| 275 | Pl 110 mm IS2062 E250 Gr Br./K TDC:386; 110 (T) x 2500 (W) x 10000 (L) [mm]; 110 X 2500 X 10000 [T X W X L] [mm] |
| 276 | PL 110 mm IS 2002 GRADE-2; TDC: AA10401 Rev. 17 ; W = 1650 ; L= 8000;[Thickness, Length (L) & Width (W) are in mm]; 110 X 1650 X 8000 [T X W X L] [mm] |
| 277 | PL 110 MM A516 GRADE-70; TDC : AA10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 2 & 3 of Annexure-1); 110 X 2000≤ W ≤2500 X 6000 ≤ L ≤ 8000 [T X W X L] [mm] |
| 278 | Pl 115 mm IS 2062 E 250 Gr A/BR/SK/K; 115 X 2000 ≤ W ≤ 2500 X 8000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 279 | PL 115 MM A516 GRADE-70; TDC : AA10403 + Supplementary Requirements: Impact Test (S5 + Sl. No. 1 & 2 of Annexure-1) + Bend Test( Sl. No. 5 of Annexure-1); 115 X W = 2500 X L = 10000 [T X W X L] [mm] |
| 280 | Pl 120 mm IS 2062 E 350 Gr B0 TDC:6:386 Rev 03; 120 X 2000≤ W ≤ 2500 X 6000 ≤ L ≤ 12000 [T X W X L] [mm] |
| 281 | PL 120 mm IS 2002 GRADE-2; TDC: AA10401 Rev. 17 ; W = 2500 ; L= 10000;[Thickness, Length (L) & Width (W) are in mm]; 120 X 2500 X 10000 [T X W X L] [mm] |
| 282 | Pl 130 mm IS2062 E350 Gr C; TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + UT: ASTM A 578 Level B.;130 mm X 2500 mm X 6000 mm : T X W X L (mm); 130 X 2500 X 6000 [T X W X L] [mm] |
| 283 | Pl 130 mm IS 2062 E 250 Gr BR/K TDC:6:386 Rev 03; 130 X 1800 X 5600 [T X W X L] [mm] |
| 284 | PL 140 mm IS 2002 GRADE-2; TDC: AA10401 Rev. 17 ; W = 2000 ; L= 10500;[Thickness, Length (L) & Width (W) are in mm; 140 X 2000 X 10500 [T X W X L] [mm] |
| 285 | Pl 190 mm IS2062 E350 Gr C TDC:301 Rev 12 + Charpy V-Notch Impact Test in both Longitudinal & Transverse Specimen + UT: ASTM A435, 190 mm X 2250 mm X 6300 mm T X W X L (mm); 190 X 2250 X 6300 [T X W X L] [mm] Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender