Tender For Supplying, Installation, Testing And Commissioning Of Public Addressing System In The Medicine Building Of Agmc & Gbp Hospital, Agartala Tripura (W)
Tender Value
23.54 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
7 days left
EMD
47100
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supplying, Installation, Testing And Commissioning Of Public Addressing System In The Medicine Building Of Agmc & Gbp Hospital, Agartala Tripura (W)
BOQ
| Sl. No. | Item Description |
| 1 | SITC of 10 Zone Remote Call Station with gooseneck microphone, LED display, keypad operation, microphone volume control, supporting RS-422 communication through RJ-45 interface, frequency response of 100Hz–15kHz (MIC) and 30Hz–18kHz (Line), operating on 24V DC supply having adapter with maximum power consumption of 10W all accessories complete as required & as directed by the Engineer-in-Charge :- |
| 2 | Supplying & laying of Cat-6 UTP LAN FRLS Cable conforming to ANSI/TIA-568 standards, including routing through existing/new PVC conduit/trunking, dressing, termination at RJ-45 I/O and patch panel, ferruling, labeling, testing and all accessories complete as required:- |
| 3 | Supply, installation, testing and commissioning of 500W Digital Class-D Power Amplifier for Public Address (PA) System, suitable for continuous duty operation, having minimum 500W RMS output power with minimum 85% efficiency, 100V line and 8 Ohm speaker outputs, balanced line input with gain control, frequency response of 20Hz–20kHz, THD: <0.1% (1KHz/-3dBv, 100W), Signal-to-Noise Ratio > 80dB, input impedance of 10kΩ, built-in high-pass filter (ON/OFF), LED indications for Power, Protection, Clip, Input and Output status, and complete protection against short circuit, overload, over-temperature, clipping and DC faults, suitable for operation on 230V AC, 50Hz required for satisfactory operation, complete as required as directed by the Engineer-in-Charge:- |
| 4 | Supplying and fixing of RJ-45 Connectors including connection etc as reqd:- |
| 5 | Supply, installation, testing and commissioning of 10 Zone Controller for Public Address (PA) System, expandable up to 300 zones through cascading, complete with 10 independent paging channel selectors, MIC-1 & MIC-2 inputs (600Ω, 5mV, unbalanced), Line-1 & Line-2 inputs (10kΩ, 775mV, unbalanced), audio output, 10-zone selector switches with LED indications, RS-422 communication interface with RJ-45 communication ports, DIP switch ID addressing, and frequency response of 100Hz–15kHz (MIC) and 30Hz–18kHz (Line), Signal-to-Noise Ratio of minimum 60dB (MIC) and 80dB (Line), Operation: 110–230V AC, 50/60Hz, maximum power consumption of 40W, complete with necessary connection and as per the directions of the Engineer-in-Charge: |
| 6 | Supplying & fixing of 2×1.5 Sq.mm (16 AWG) Speaker Cable, made of high-conductivity stranded electrolytic annealed copper conductors with PVC insulation and overall FR/FRLS PVC sheath, conforming to relevant IS/IEC standards with necessary connection etc as required & as directed by the Engineer-in-Charge:- |
| 7 | Supplying, installation, testing and commissioning of 6 W Box On Wall Speaker built-in 70V/100V line matching transformer, Impedance 6W-1.7kOhms, 10-1.1 kOhms, minimum sensitivity of 96dB, frequency response of 120Hz–16kHz including connection etc as reqd & as per the directions of the Engineer-in-Charge:- |
| 8 | SITC of 9U wall-mounted network rack with glass front door, adjustable rails, fan unit, pdu, cable manager and complete mounting hardware including connection etc as reqd:- |
| 9 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 10 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 11 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- |
| 12 | 2 X 2.5 sq mm |
| 13 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 14 | 1 X 1.5 sq mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender