Tender For Repairs To The Fire Prevention System And Renewal Of Fire Noc At Pjn Stadium Fatorda.
Tender Value
13.14 Lakhs
Estimated cost
Bid Submission
28 Sep 2026
14 days left
EMD
26300
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs To The Fire Prevention System And Renewal Of Fire Noc At Pjn Stadium Fatorda.
BOQ
| Sl. No. | Item Description |
| 1 | Rewinding and servicing of 12.5 HP Jockey Pumps including replacement of non working spare part as required by Engineer in Charge. |
| 2 | Rewinding and servicing of 50 to 60 HP sprinkler/hydrant Pumps including replacement of non working spare part, alignement of motor and pump set replacement of bearings and painting the pump with primer and red paint as required by Engineer in Charge. |
| 3 | Supplying and Erecting Fuel Filter along with Sealing rings, gasket, primary filter and water separator etc. complete suitable for Diesel Engine Driven Pump of 60 HP |
| 4 | Supplying and erecting Air Cleaner/Air Filter element suitable for Diesel Engine Driven Pump of 60 HP |
| 5 | Supplying and erecting oil Filter and element suitable for Diesel Engine Driven Pump of 60 HP |
| 6 | Replace lubricating Oil 15W/40 Grade of approved make as per IS 13656-2014 for Diesel Engine Driven Pump of 60 HP |
| 7 | Supplying and erecting Stop Solenoid Assembly 12V single coil energized to run with or without Primary etc complete suitable for Diesel Engine Driven Pump of 60 HP |
| 8 | Supplying erecting and circuit wiring of SMPS based Battery Charger input voltage 230 V A.C. & output voltage 24 V DC, charging current 10A suitable to charge DG set Battery |
| 9 | Supplying and erecting 12V 150 AH Heavy Duty plate type Battery with Terminal Wire Duly charged complete suitable for DG Set with Warranty of 3 years |
| 10 | Carrying out servicing of Diesel Pump set upto 60 HP of any make to ensure smooth running of DG set for 30 minson load. Checking for abnormal sound and leakages, carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly,Also making the Auto operation of pump incase of emergencyas per fire norms complte Job. Submit the servicing report to engineer in charge.painting the pump set as per fire norms. |
| 11 | Supplying, Erecting, Testing and Commissioning of Low Lub Oil Pressure for Diesel Engine Driven Pump of 60 HP |
| 12 | Servicing of hydrant valve, replacing its rubber etc and its painting as required by the fire dept. |
| 13 | Supply, Installation of Hose box made of PVC/UPVC/FIBER or as required by fire department with double door with 4mm thick glasses and housing for hose pipe and branch pipe. and having front doors with viewing glass (8\\"x6\\") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour. and Rates include for suitable size iro brackets and anchor bolts as required by Engineer in Charge.. |
| 14 | Supply, Installation, Testing and Commissioning of 63 mm dia RRL Hose 15 mtr length with ISI marked brass mala & female coupling (IS:903) bound & rivetted to hose pipe with copper rivets complete as per Goa fire Dept. requirement. |
| 15 | Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling. |
| 16 | Servicing of 2 way fire brigade inlet replacement of gaskets rubber etc as required by Engineer in Charge. |
| 17 | Servicing of fire alaram pannel with replacement of battery and other non working spare and make the system healthy as required by Engineer in Charge. |
| 18 | Supply and installation of Addressable type manual call point and addressing the same in the existing fire panel as required by Engineer in Charge. |
| 19 | Supply and installation of the Fire system Addressable type dual hooter with flash light and addressing the same in the existing fire panel as required by Engineer in Charge. |
| 20 | Supply and installation of the Fire system Addressable type smoke detectors with base and addressing the same in the existing fire panel |
| 21 | Refilling of 4.5 kg CO2 type Fire Extinguisher including transport charges |
| 22 | Refilling of 4 kg ABC type Fire Extinguisher including transport charges |
| 23 | Supply and fixing of directional exit,fire safety,person with disability and assembly point signage's as per fire department norm as required by Engineer in Charge. |
| 24 | Supply, Installation & Testing of First aid Hose reel conforming to IS 884 completes with 19 mm dia bore reinforced braided rubber hose of 30 mtrs length fitted with 6.35mm dia shut off Nozzle, 25 mm dia ball valve etc. The hose reel shall be manual 180 deg. swinging type with reel drum hose shall be provided with coupling. |
| 25 | Servicing of wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete. |
| 26 | Supply and installation of 4.5 kg CO2 type Fire Extinguisher as per Goa Fire Dept. norm. |
| 27 | Supply and installation of 9 kg CO2 type Fire Extinguisheras per Goa Fire Dept. norm. |
| 28 | Supply and installation of 4 kg ABC type Fire Extinguisher as per Goa Fire Dept. norm. |
| 29 | Supply and installation of battery backup electrical power supply exhit sign board as per fire departnment norm . |
| 30 | Supply and installation of butterfly valve 50 MM as required by Engineer in Charge. |
| 31 | Supply and installation of Non return valve 50 MM as required by Engineer in Charge. |
| 32 | Supply and installation of submersibal 1 HP water pump set including realignment and make necessary piping etc for dewtering the water accumulated inside pump room with Auto On/OFF provision depending on Water accumulation and hooter sound when pump starts .as required by Engineer in Charge. |
| 33 | Supplying & erecting cast iron Dual Plate NRV of size 150 mm dia. With matching flanges and accessoriese complete as required by Engineer in Charge. . |
| 34 | Supplying and installing pressure gauge of 100mm dia, 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. Pad cock valve, and G.I. pipe, elbow etc. complete .as directed by Engineer Incharge. |
| 35 | Supply and installation pressure switch with 12/15mmdia isolation valveGI nipple elbow etc. complete as required by Engineer incharge. |
| 36 | carrying out complete repair of fire Alrm and fire hydrant system by execution as per instructions of engineer incharge and obtaining renewal of Fire NOC from the fire department with required testing and commisssioning of the system as per requirements of the fire department completing procedures and paymentof fees etc. |
| 37 | Supply of Refrigerants gas R410/R 32 doe split type AC |
| 38 | Supply and installation of 5 KVA voltage stabilisers for 2 TR Split AC units of Make Everest or Equivalent as directed by Engineer incharge. |
| 39 | Supply and Laying of 2 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.2 core 2.5 Sq.mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender