Tender For Repair/ Maintenance Of Solar Water Heater, Water Level Indicators On Ohr/ Ug Sump, Hooter/ Siren System And Allied Works At Af Stn Jmr And Repair Of Old Vintage Amf Panel & Watch Tower Search Lights Alongwith Connected Works At Ramgarh Und
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Solar Water Heater, Water Level Indicators On Ohr/ Ug Sump, Hooter/ Siren System And Allied Works At Af Stn Jmr And Repair Of Old Vintage Amf Panel & Watch Tower Search Lights Alongwith Connected Works At Ramgarh Under Ge(Af) Jaisalmer
BOQ
| Sl. No. | Item Description |
| 1 | Supply,Install,testing & commissioning in replacement factory made and tested AMF panel 160 KVA indoor type platform mounted suitable for 15 volts 3 Phase and neutral wire,50 Hz AC supply system having busbar with insulated sleeves aluminium busbar of 250 amps rating.The panel shall be dust & vermin proof protection class (IP-42) and made of 2.00 mm thick CRCA sheet suitable angle iron frame work made out of 50 x 50 x 6mm front opening type with proper ferrule & cable gland,internal wiring with PVC insulated multistranded copper conductor PVC wire of adequate size but less than 1.5 Sqmm complete.All sheet metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of siemen grey shade 7035 embedded ground with & including blocks of PCC 1:2: type B1 block size 30 x 30 x 30 cm complete all as specified and directed by Engr-in-Charge.Make : Adiec/Schneider/Universal Switch Gear Control/Tricolite The scope of work also comprising of the following : -(a) Control MCB SP 6 Amp 230 Volt (b) Control MCB SP 16 Amp 230 Volt (c) Battery charger 12/24 DC (d) LED Indicating light for main & DG(e) LED Indicating light for main & Gen ON (f) LED Indicating light for Battery charger(g) Digital voltmeter (0-500V) flush mounted 96 mm x 96 mm with selector switch (h) Digital ammeter (0-250 Amps) flush mounted 96 mm x 96 mm with selector switch (j) CT Coil 250/5A CL-1 (k) DC Voltmeter 15/30V analog type (l) DC Ammeter 0-15 A analog type (m) Trickle/Boost switch & selector switch (n) Auto/Manual Selector Switch (o) Start/Stop Push Buttton (p) Hooter 12/24V DC (q) Auto main failure controller (AMF) with LCD display 96 x 96 mm (Model-DGC6D)(r) Power Contactor 255 Amps Pole having coil voltage 220 V AC for DG Supply(s) Power Contactor 255 Amps Pole having coil voltage 220 V AC for Main Supply (t) MCCB 250 Amps 25 KA 4 Pole with adjustable thermal & fixed magnetic release 15 Volts,50 Hz for main supply (u) MCCB 250 Amps 25 KA 4 Pole with adjustable thermal & fixed magnetic release 15 Volts,50 Hz for DG supply(v) Over load relay 3-5 A (w) Control relay 12/2 V DC (x) Danger Notice Plate (y) Enclosure of suitable size along with internal wiring & Buisbar chamber 250 Amp Strips Aluminium Note : AMF Panel manufacturer should have following Government approved certificates :-(a) Panel Should be according to IEC -61439.CPRI Certification degree of protection IP-54 (IS/IEC-6139 (part-I),2011 & (IS/IEC-6139 (part-II) 2011 (b) Temperature rise (IS/IEC-61439 (part-I),2011 & (IS/IEC-61439 (part-II) 2011.(c ) CPRI short circuit IEC -61439 1 & 2 withstand strength should be 70 Karms for 1.0 sec with initial peak of 15kApk.(d) CPRI Certification IEC -61439 1 & 2 ratted current for short circuit not less than 4000A with rated insulation voltage 660 V.(e) ISO 9001 certified. Please Enable Macros to View BoQ information |
| 2 | Supply,Install,testing & commissioning in replacement factory made and tested AMF panel 160 KVA indoor type platform mounted suitable for 15 volts 3 Phase and neutral wire,50 Hz AC supply system having busbar with insulated sleeves aluminium busbar of 250 amps rating.The panel shall be dust & vermin proof protection class (IP-42) and made of 2.00 mm thick CRCA sheet suitable angle iron frame work made out of 50 x 50 x 6mm front opening type with proper ferrule & cable gland,internal wiring with PVC insulated multistranded copper conductor PVC wire of adequate size but less than 1.5 Sqmm complete.All sheet metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of siemen grey shade 7035 embedded ground with & including blocks of PCC 1:2: type B1 block size 30 x 30 x 30 cm complete all as specified and directed by Engr-in-Charge.Make : Adiec/Schneider/Universal Switch Gear Control/Tricolite The scope of work also comprising of the following : -(a) Control MCB SP 6 Amp 230 Volt (b) Control MCB SP 16 Amp 230 Volt (c) Battery charger 12/24 DC (d) LED Indicating light for main & DG(e) LED Indicating light for main & Gen ON (f) LED Indicating light for Battery charger(g) Digital voltmeter (0-500V) flush mounted 96 mm x 96 mm with selector switch (h) Digital ammeter (0-250 Amps) flush mounted 96 mm x 96 mm with selector switch (j) CT Coil 250/5A CL-1 (k) DC Voltmeter 15/30V analog type (l) DC Ammeter 0-15 A analog type (m) Trickle/Boost switch & selector switch (n) Auto/Manual Selector Switch (o) Start/Stop Push Buttton (p) Hooter 12/24V DC (q) Auto main failure controller (AMF) with LCD display 96 x 96 mm (Model-DGC6D)(r) Power Contactor 255 Amps Pole having coil voltage 220 V AC for DG Supply(s) Power Contactor 255 Amps Pole having coil voltage 220 V AC for Main Supply (t) MCCB 250 Amps 25 KA 4 Pole with adjustable thermal & fixed magnetic release 15 Volts,50 Hz for main supply (u) MCCB 250 Amps 25 KA 4 Pole with adjustable thermal & fixed magnetic release 15 Volts,50 Hz for DG supply(v) Over load relay 3-5 A (w) Control relay 12/2 V DC (x) Danger Notice Plate (y) Enclosure of suitable size along with internal wiring & Buisbar chamber 250 Amp Strips Aluminium Note : AMF Panel manufacturer should have following Government approved certificates :-(a) Panel Should be according to IEC -61439.CPRI Certification degree of protection IP-54 (IS/IEC-6139 (part-I),2011 & (IS/IEC-6139 (part-II) 2011 (b) Temperature rise (IS/IEC-61439 (part-I),2011 & (IS/IEC-61439 (part-II) 2011.(c ) CPRI short circuit IEC -61439 1 & 2 withstand strength should be 70 Karms for 1.0 sec with initial peak of 15kApk.(d) CPRI Certification IEC -61439 1 & 2 ratted current for short circuit not less than 4000A with rated insulation voltage 660 V.(e) ISO 9001 certified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender