Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57484180

Tender For Special Repair With Replacement Of Old Overhead Conductor Into Underground Cable At Lekhapani Mil Stn Under Ge Dinjan No.2

Issued by Statutory Bodies & Commissions/Committees · Tinsukia, Assam
Tender Value
38.50 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
20 days left
EMD
77000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair With Replacement Of Old Overhead Conductor Into Underground Cable At Lekhapani Mil Stn Under Ge Dinjan No.2

BOQ

Name of Work:- SPECIAL REPAIR WITH REPLACEMENT OF OLD OVERHEAD CONDUCTOR INTO UNDERGROUND CABLE AT LEKHAPANI MIL STN UNDER GE DINJAN NO.2
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for laying under ground cables/pipes etc and getting out any type soil complete all as specified and directed by Engineer in charge
2Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cm complete all as specified and directed by Engineer in charge
3Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and directed by Engineer in charge
4M&L for Boring of holes under road, pavement, hard standing by trenchless technology technique for 40-80 mm dia pipe complete all as specified and directed by Engineer in charge.
5Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts complete all as specified and directed by Engineer in chargeNote : - Only punned thickness shall be measured for payment purpose
6M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class\\"B\\" laid dry and flat and width wise along the axis of the trench complete all as specified and directed by Engineer in charge.
7M&L for laying of double wall corrugated HDPE pipe alongwith its fittings for jointing of pipe in trench for cable protection of 40mm dia complete all as specified and directed by Engineer in charge
8M&L for laying of double wall corrugated HDPE pipe alongwith its fittings for jointing of pipe in trench for cable protection of 50mm dia complete all as specified and directed by Engineer in charge
9M&L for laying of double wall corrugated HDPE pipe alongwith its fittings for jointing of pipe in trench for cable protection of 90mm dia complete all as specified and directed by Engineer in charge
10Supply, laying & testing insulated XLPE UG cable 1100 volts grade, armoured heavy duty confirming to relevant IS specifcations with aluminum conductor of size 240 sq mm 3.5 core complete all as specified and directed by Engineer in charge
11Description all as per item No.10 here in before but 185 sq mm 3.5 core
12Description all as per item No.10 here in before but 150 sq mm 3.5 core
13Description all as per item No.10 here in before but 120 sq mm 3.5 core
14Description all as per item No.10 here in before but 95 sq mm 3.5 core
15Description all as per item No.10 here in before but 70 sq mm 3.5 core
16Description all as per item No.10 here in before but 50 sq mm 3.5 core
17Description all as per item No.10 here in before but 35 sq mm 3.5 core
18Description all as per item No.10 here in before but 25 sq mm 3.5 core
19Description all as per item No.10 here in before but 16 sq mm 4.0 core
20Description all as per item No.10 here in before but 10 sq mm 4.0 core
21Description all as per item No.10 here in before but 10 sq mm 2.0 core
22Description all as per item No.10 here in before but 6 sq mm 2.0 core
23Dismantling /Taking down ACSR conductors from the disturbed span including jumper, removing the binding from insulator, of any size for LT OH Line/ structures, etc complete all as specefied and directed by Enginneer in charge
24Dismantling/taking down old unserviceable cross arms, bracings, support, clamp including nuts, bolts and washers complete all as specefied and directed by Enginneer in charge
25Dismantling/Taking down insulators any type, any size complete all as specefied and directed by Engineer in charge
26Dismantling/Taking Down earth wire 40mm or any size complete all as specefied and directed by Engineer in charge
27M&L straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 10/16 to 35 sqmm 3.5/4.0 core and testing complete all as specefied and directed by Enginneer in charge
28M&L straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 50 to 95 sqmm 3.5 core and testing complete all as specefied and directed by Enginneer in charge.
29M&L straight through joints (heat shrinkable type) cable joint kit including jointing materials for making joints of UG electric cable 1100 volt grade heavy duty with PVC/XLPE insulated aluminium conductor nominal cross sectional area 70 to 185 sqmm 3.5 core and testing complete all as specefied and directed by Enginneer in charge.
30M&L for plain cement concrete type C1 (1:3:6) using 40 mm graded stone aggregate as in coping of pole/ any floor/path including necessary form work and finishing exposed surface/white washing complete all as specefied and directed by Engineer in charge
31Supply and fixing thermo plastic cable terminal box of size not less then 155x210x92mm with Cable Gland /terminals with locking arrangments including necessary mounting arrangement of any steel tubular/RCC poles with suitable size of clamps nuts bolts washer etc. fixed with poles including one single pole MCB of capacity 6-32A and PVC connector for cable termination complete all as specefied and directed by Engineer in charge
32Supply & fixing wheather proof copper three core cable of size 1 Sqmm drawn in and including PVC conduit medium grade not less than 15mm dia along with all fixing accesories, fixed to pole/wall with suitable size clamps or fixing accessories complete all as specefied and directed by Engineer in charge
33M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point/panel upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specefied and directed by Engineer in charge
34M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, comprising the following complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 350 Amps, 36 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt)of suitable size having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA with LED display, of suitable size with 3 Nos CT (200/5)- 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set and internal wiring with suitable size of copper cable(ii) BUSBAR :- Aluminium bus bar for 4 pole of capacity 550 Amps- 01(iii) OUTGOING:- (a) MCCB, 4P, 160Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b)MCCB, 4P, 100Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(c) MCCB, 4P, 63 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(d) MCB,SPN, 32 Amp,16kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos(e) MCB,TPN, 63A, 240 V, 18 kA - 01 Nos. (For street light)
35M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 100 Amps, 25 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA burden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set. & Instrumental control wiring MCB/fuse min 3 Amps - 03 Nos.(ii) BUSBAR :- Aluminium bus bar 4 Strip of minimum capacity 200 Amps- 01 (set of 04)(iii) OUTGOING:- (a) MCCB, 4P, 40 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 Nos with Thermal and Magnetic release(b) MCB, TPN, 40 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 03 No(c) MCB, SPN, 20 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No
36M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items, complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 160 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No with Thermal and Magnetic release(b) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA burden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set. & Instrumental control wiring MCB/fuse min 3 Amps - 03 Nos.(ii) BUSBAR :- Aluminium bus bar 4 Strip of minimum capacity 250 Amps- 01 (set of 04)(iii) OUTGOING:- (a) MCCB, 4P, 100 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b) MCCB, 4P, 63 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(c) MCB, TPN, 32 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 02 No
37M & L for fabrication of LT feeder pillar box, out door type, double door, tent roof, factory made totally enclosed, dust and vermin proof, double leaf shutter in front and rear side made out of 3.15 mm thick CRCA sheet of of suitable size and mounted on MS angle 50 mm X 50 mm X 6 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, aluminium bus bar with colour sleeve, mounted on insulator with opening door both side with rubber bedding, locking arrangement and painting to both internal and external surfaces with powder coating paint in heat process in grey colour incl mounted on PCC foundation upto a suitable height as required at site with earth work and connecting items complete all as specified and as directed by Eng-in-charge.(i) INCOMING :- (a) MCCB, 4P, 100 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No(b) Digital voltmeter 3 Phase( 0-500 volt) 96mm x 96mm having accuracy class 1.0, 4.5 digit LED display - 01 No.(c) Digital Ammeter three Phase having accuracy class 1.0, 4.5 digit 0.5 VA burden with LED display, size 96mm x 96mm with 3 Nos CT (200/5)- 01 No (d) LED R-Y-B indicating lamps (Set of Three)- 01 set. & Instrumental control wiring MCB/fuse min 3 Amps - 03 Nos.(ii) BUSBAR :- Aluminium bus bar 4 Strip of minimum capacity 200 Amps- 01 (set of 04)(iii) OUTGOING:-(a) MCCB, 4P, 63 Amps, 35 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 Nos(b) MCB, SPN, 40 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 03 No(c) MCB, SPN, 32 Amps, 16 kA rupturing capacity, 415 volts, AC, 50 Hz- 01 No
38S&F Bus bar chamber / LT distribution board outdoor top canopy type, made out of 3.15 mm thick CRCA sheet weather/vermin proof, front door open type, 3 phase 4 wire, 440 volts , AC, 50Hz, with TPN aluminium bus bar of capacity 200 Amps rated with PVC insulated colour code sleves, mounted on porceclain insulators, complete with R-Y-B indicating lamps, duly wired including locking arrangement , cable gland for incoming and outgoing cables of suitable sizes, panel size not less than 600mm x 600mm x 450mm, mounting MS angle base frame duly painted with synthetic enamel black paint and totally mounted on PCC(1:3:6) foundation upto a height of 45 cm above ground level complete all as specified and directed
39Supply & fix Timer distribution board/street light panel outdoor type IP 54 rating as per standard specification and suitable size of capacity 32/40A, (Min Load Capacity 6 KW) 230 volt single pole with astronomical/digital time switch, contactor, MCBs and out going terminal with necessary mounting arrangement as per sample including complete all as specified and directed by Engineer-in-Charge. Note : Height of the panel shoulld not less than 600mm from GL.
40S&F cable route indicator of 60 cm Height made of MS flat iron 30 x 5 mm duly welded round shape MS plate of 15 mm Dia, 5 mm Thick written with \\"MES LT Cable\\" on the route of cable including neccesary excavation, PCC and fabrication duly painted by 1 Coat Red Oxide & 1 coat Synthatic enamel black paint all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57484180
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.50 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair With Replacement Of Old Overhead Conductor Into Underground Cable At Lekhapani Mil Stn Under Ge Dinjan No.2
Basic Detail
Tender No 8987/E8
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 11 Sep 2026
Submission Date 03 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 38.50 Lakhs
Tender Fee 500
EMD 77000
Exemption Available
Document List
b4a00324-d5f9-4e42-9ed9-bd3f212891e0.html
BOQ_884127.xls
Tender.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

b4a00324-d5f9-4e42-9ed9-bd3f212891e0.html

xls

BOQ_884127.xls

pdf

Tender.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders