Tender For Repair / Maintenance Of Unserviceable Building Meter Panels, Control Switchgears, Shaft Wiring, Cable Trunking And Distribution Boxes Of High Rise Building At Rs Colaba Under Ge (Nw) Navy Nagar, Colaba, Mumbai
Tender Overview
Project Description
Tender for Repair / Maintenance Of Unserviceable Building Meter Panels, Control Switchgears, Shaft Wiring, Cable Trunking And Distribution Boxes Of High Rise Building At Rs Colaba Under Ge (Nw) Navy Nagar, Colaba, Mumbai
BOQ
| Sl. No. | Item Description |
| 1 | S&F in replacement of MCB DB SPN conforming to as per IEC 61439-3 and IP 43, IK 09 with acrylic door, 4 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls. |
| 2 | All as per item No. 1.00 above but MCB DB SPN 8 way. |
| 3 | All as per item No. 1.00 above but MCB DB SPN 12 way. |
| 4 | S&F in replacement of MCCB DB VTPN 4 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earth bar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complele all as specified and directed. |
| 5 | All as per item No. 4.00 above but MCCB DB VTPN 8 way complele all as specified and directed. |
| 6 | S&F in replacement of MCCB 125A, 16kA, 4P, Thermal magnetic release , Ics=100% Icu complele all as specified and directed. . |
| 7 | S&F in replacement of MCB TP 63A, 10kA, 415V complele all as specified and directed. . |
| 8 | S&F in replacement of MCB SPN, 32 Amp, 10 KA, 230 Volt complele all as specified and directed. |
| 9 | S&F in replacement of MCB SP 40A, 10kA, 240V, C series complele all as specified and directed. |
| 10 | S&F in replacement of MCB, single pole, upto 32 Amp, 10 KA, 230 , C series Volt complele all as specified and directed. |
| 11 | S & F in replacement with cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified. |
| 12 | M & L in replacement for DLP trunking system of size 80x50mm fixing on wall with & including all accessories like cover, base joints, cover joints, flat angles, internal angles, external angles, partition etc Complete all as specified and directed. |
| 13 | Taking out old existing unarranged communications cable/conduits/casing caping/Lightening Protection cable from wall surfaces and keep a side and refixing the same after making good of wall surfaces under cable trunking/trays or using saddling complete all as specified and directed. |
| 14 | Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ points complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of ceiling, walls, floors, etc. |
| 15 | Material and labour for point wiring with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling /floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm. |
| 16 | One light/exhaust/ceiling fan point controlled by one switches. |
| 17 | One 3 pin switch socket combination 5 Amps on the same board with other switches. |
| 18 | One 3 pin switch socket combination 5 Amps on independendent. |
| 19 | One bell point controlled by one push button. |
| 20 | All as per item No 15.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch. |
| 21 | S & F modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. |
| 22 | S & F in replacement with modular switch, 1 module, single pole one way 6 Amp conforming to IS:3854 and ISI marked complete all as direcred. |
| 23 | S & F modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. |
| 24 | S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. |
| 25 | S & F modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. |
| 26 | S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. |
| 27 | S & F modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. |
| 28 | S & F in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. |
| 29 | S & F modular stepped type fan regulator, 2 module, single pole one way ISI marked. |
| 30 | S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way. |
| 31 | S & F modular bell push switch, 1 module, single pole one way 6Amp ISI marked. |
| 32 | S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. |
| 33 | Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed. |
| 34 | Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 35 | Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F in replacement with modular PVC Gang box of 8 module, ISI marked for mounting of modular switches and sockets including lank plate for blank module. |
| 36 | All as per Item No- 35.00 above but of modular PVC Gang box, 4 module. |
| 37 | All as per Item No- 35.00 above but of modular PVC Gang box, 3 module. |
| 38 | All as per Item No- 35.00 above but of modular PVC Gang box, 1/2 module. |
| 39 | S&F modular white cover plate with frame, 8 module. |
| 40 | S&F modular white cover plate with frame, 4 module. |
| 41 | S&F modular white cover plate with frame, 3 module. |
| 42 | S&F modular white cover plate with frame, 1/2 module. |
| 43 | Taking down unserviceable FTL/batten fittings with supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. |
| 44 | All as per Item No-43.00 above but Slim LED integrated batten of 10 Watt 2ft complete. |
| 45 | S&F in replacement 10W LED batten with inbuilt smart motion sensor, 230 Volt , 50 Hz , 2 feet, polycarbonate extruted channel, powder coated with diffuser for glare free light, Inbuilt motion sensor prewired with 25% dimmer illuminous in ideal time with all accessories including two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose complete with following specification. (i) housing-polycarbonate extrusion,diffuser- opal- polymer, LED type- MID power ,Light distribition- general Spread, LED efficiency - > 130 lumen/Watt, System effieciency- > 100 lumen/Watt, Driver efficiency - more than 85%, power factor- more than 0.95, THD - <10%, Mounting/Fixing- Wall/Ceiling, Ingress Protection - IP-20, Sensor type- HF inbuilt integral occupancy/movement sensor, sensor range- upto 5 mtrs(cone formation ), Dimming operation- default operation at 25% of the is rated value. On detection of motion, light output rises to 100% for upto 20 sec . in absence of otion switches back to default operation, LED life- upto 30,000 Hrs.Surge Protection- not less than 1KV. |
| 46 | S & F in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as directed. |
| 47 | S & F in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp rating conforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as directed. |
| 48 | S & F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm. |
| 49 | S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm. |
| 50 | S & F in replacement with electric bell ding dong, AC, 230V single pole. Please Enable Macros to View BoQ information |
| 51 | S & F in replacement with electric bell ding dong, AC, 230V single pole. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender