Tender For Maintenance Of Sewer Network In Sector C And D In Akhnoor Mil Stn Under Ge (S) Akhnoor.
Tender Overview
Project Description
Tender for Maintenance Of Sewer Network In Sector C And D In Akhnoor Mil Stn Under Ge (S) Akhnoor.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 02-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches, not exceeding 1.50m wide and not exceeding 1.50m in depth; for foundation or for laying of pipe etc., not exceeding 10 Sqm on plan and not exceeding 1.50mtr in depth and getting out, in any type of soil, complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 150mm/200mm internal dia, set in cement mortar, complete all as specified and as directed by Engineer-in-Charge. |
| 3 | M&L for plain cement concrete M-10 (1:3:6), type C-2 (using 40mm crushed stone aggregates) as in concrete bed to drain pipes of 200mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-in-Charge. |
| 4 | M&L for plain cement concrete M-10 (1:3:6), type C-2 (using 40mm crushed stone aggregates) as in concrete bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; after laying, complete all as specified and as directed by Engineer-in-Charge. |
| 5 | Salt-glazed stoneware drain pipes, Grade 'A' internal 150mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-in-Charge. |
| 6 | Salt-glazed stoneware drain pipes, Grade 'A' internal 200mm, laid in trenches and jointed in cement mortar 1:1, complete all as specified and as directed by Engineer-in-Charge. |
| 7 | M&L for reinforcement cement concrete NP2 drain pipes, internal 200mm laid in trenches and jointed with collars in cement mortar 1:1, complete all as specified and as directed by Engineer-in-Charge. |
| 8 | Returning, filling in, including spreading, levelling , watering and well ramming of earth in layers not exc 25 cm, complete all as specified and as directed by Engineer-in-Charge. |
| 9 | Removing excavated material to a distance not exc. 50 mtr and depositing where directed at a level not exc. 1.5mtr above the starting point, complete all as specified and as directed by Engineer-in-Charge. |
| 10 | Cleaning and Clearing blokage of WC's including traps, CI/PVC pipe laid in trenches or fixed to wall of any dia upto four storey and including 1st manhole etc., complete all as specified and directed. |
| 11 | Cleaning and Clearing blokage of floor trap, nahani trap etc., including CI/PVC pipe laid in trenches or fixed to wall of any dia upto four storey upto 1st manhole etc., complete all as specified and directed. |
| 12 | Cleaning of sewage lines 150mm dia of any length and at any depth by mechanical means, flushing the sewage lines with water after removing sludge including taking off the manhole cover and refixing after cleaning of manhole on both side of pipe of any size and depth and sludge to be removed to outside of cantt area, complete all as specified and directed. |
| 13 | Cleaning of sewage lines 200mm dia of any length and at any depth by mechanical means, flushing the sewage lines with water after removing sludge including taking off the manhole cover and refixing after cleaning of manhole on both side of pipe of any size and depth and sludge to be removed to outside of cantt area, complete all as specified and directed. |
| 14 | Note for Item 10 to 13 :(a) The contractor himself or his representative with 02 Nos of labour safaiwala with cleaning equipments (as directed by Engr-in-Charge) will attend the complaint cell of AGE B/R-I office to recieve comoplaints everyday at 8:30am to clear, clean and complete the item 10 to 13 within 8:00 Hrs.(b) In case of failing to complete the complaint for Items at 10 to 13 within stipulated time period Rs 600 recovery Per Day will be effected .(c) Removal and refixing of grating with white cement is deemed to be included in relevent Item rates quoted by contractor and no extra payment will be admissible.(d) The contractor will ensure the cleaning/clearing of all the complaints (irrespective of Nos) within 08 Hrs by deploying additional sewerman/ safaiwala, if needed. Nothing extra will be paid on this account.(e) Damage to any existing services or items will be made good by replacing the item with same nature and nothing extra will be paid on this account.(f) Complaint slip will be deposited by contractor himself or by his representative after getting signature of occupant for completion of job done at same day to concerned JE at AGE B/R-I Office. |
| 15 | M&L for cleaning of 10 User septic tank (sludge, dewatering etc) by mechanical means including removing of manhole cover and refixing the same with cement mortar 1:4, any numbers of chamber, cover etc including washing of septic tank with water and lime wash inside ( sludge and sewage water) to be carried out in sealed vehicle mounted container and disposed off outside of cantt, complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for cleaning of 20 user septic tank (sludge, dewatering etc) by mechanical means including removing of manhole cover and refixing the same with cement mortar 1:4, any numbers of chamber, cover etc., including washing of septic tank with water and lime wash inside ( sludge and sewage water) to be carried out in sealed vehicle mounted container and disposed off outside of cantt complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for cleaning of 50 User Septic tank (sludge, dewatering etc) by mechanical means including removing of manhole cover and refixing the same with cement morat 1:4, any numbers of chamber, cover etc including washing of septic tank with water and lime wash inside ( sludge and sewage water) to be carried out in sealed vehicle mounted container and disposed off outside of cantt, complete all as specified and directed by Engr-in-Charge. |
| 18 | M&L for cleaning of 100 User Septic tank (sludge, dewatering etc) by mechanical means including removing of manhole cover and refixing the same with cement mortar 1:4, any numbers of chamber, cover etc. including washing of septic tank with water and lime wash inside ( sludge and sewage water) to be carried out in sealed vehicle mounted container and disposed off outside of cantt, complete all as specified and directed by Engr-in-Charge. |
| 19 | M&L for cleaning of soak well of any dia and depth (sludge, dewatering etc) by mechanical means including removing of manhole cover and refixing the same with cement mortar 1:4, any numbers of chamber, cover etc including washing of soak well with water including removal of old brick bats complete from inside and filling new brick bats upto 300mm depth ( Sludge and sewage water) to be carried out in sealed vehicle mounted container and disposed off outside of cantt, complete all as specified and directed by Engr-in-Charge. |
| 20 | Demolition of reinforced cement concrete of any description and in any position, not otherwise specifically provided for, complete all as specified and as directed by Engineer-in-Charge. |
| 21 | M&L for providing precast cement concrete (reinforced) type C-1 1:3:6 using 20mm graded crushed stone aggregate in landing, cover slabs set in cement mortar 1:6 including necessary form work, placing in desired position, complete all as specified and directed.Note : Reinforcement will be measured and paid separately under relevent item. |
| 22 | S&F for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia., complete all as specified and as directed by Engineer-in-Charge. |
| 23 | S&F for mild steel Fe-290 Gde E-165 as in side angle of manhole cover and like, etc. including necessary welding making in shape and size and fixed with RCC or brick member, complete all as specified and directed by Engineerr-in-Charge. |
| 24 | S&F in repair PVC valveless, syphonic action, flushing cistern 10 ltr capacity, low level, white, with inlet ball valve, float and handle including brackets, complete all as specified and directed. |
| 25 | S&F in repair for vitreous china squatting pan, 'Orissa' pattern, size 580x440mm white, with integral foot rest including trap, PVC flushing pipe, complete all as specified and directed. |
| 26 | S&F in repair for vitreous china wash down water closet pan (pedestal pattern), white (including fixing bolts, flush pipe but excluding flushing cistern) and including plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and making good to dismantled/ damaged floor in cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregates), complete all as specified and directed. |
| 27 | S&F in repair for vitreous china wash down water closet pan single piece in white shade of size 365x675x740mm, with and including PP soft close slim seat cover, hinges, dual flushing cistern fitting, fixing accessories, S/P trap, and accessories set, including necessary fixing arrangement as per manufactures instruction, complete all as specified and directed. |
| 28 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick, edgeless, area of each tile exc 0.11 sqm but n. exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in colored cement to match Shade, pattern, laying etc, including screed bed or bedding layer of cement mortar 15mm thick for laying floor finishes in cement mortar 1:6 as directed at siite, including taking down existing tiles, complete all as specified and directed by Engineer-in-Charge. |
| 29 | M&L for glazed ceramic coloured tiles 450x300x7mm thick on vertical surfaces such as skirting, dados and rises to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match pattern and shade, including 10mm thick in cement mortar 1:4 on fair faces of brick work finished even and fair to receive tiles, including taking down existing tiles, complete all as specified and directed by Engineer-in-Charge. |
| 30 | S&F in repair for bib taps, cast copper alloy, fancy type, chromium plated, long body with crutch or butterfly handles, screwed down, screwed for 15mm bore GI pipe or for brass ferrule or to GI socket, complete all as specified and directed. |
| 31 | S&F in repair for angular stop/concealed cock with all flange, cast copper alloy, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed both ends for 15mm bore GI pipe or for brass ferrule or to GI socket, complete all as specified and directed. |
| 32 | S&F in repair for PVC connection 15mm bore size with PTMT nuts of length 45cm length, complete all as specified and directed. |
| 33 | Demolition of concrete of any description and in any position not otherwise specifically provided for, complete all as specified and as directed. |
| 34 | M&L for plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specifed and as directed. |
| 35 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed. |
| 36 | M&L for brick work with sub class 'B' bricks old size straight or curved in plane exc. 6m mean radius built in cement mortar 1:6, complete all as specified and directed by Engineer-In-Charge. |
| 37 | Description all as per Serial item No.34 here in before but except brick, complete all as specified and directed by Engineer-In-Charge. |
| 38 | M&L for plain cement concrete, type B-2, 1:2:4 using 40mm graded crushed stone aggregate in surface channels and drains, complete all as specified and directed by Engineer-in-Charge. |
| 39 | M&L for extra for forming fair finished drain or channel 30cm inner grith in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified and directed. |
| 40 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of wall , finished even & smooth without using extra cement, complete all specified and directed. |
| 41 | M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement based paint over coat of primer, complete all as specified and as directed. |
| 42 | Dismantling/ taking out of cast iron drain pipe of 75/100mm bore (of any specifications), as fixed on walls or laid in trenches, complete all as specified and as directed . |
| 43 | S&F in repair for 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with PVC bat Clamps, complete all as specified and directed. |
| 44 | S&F in repair for 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with PVC bat Clamps, complete all as specified and directed. |
| 45 | S&F in repair for 110mm PVC (SWR) bend any radius, complete all as specified and directed. |
| 46 | S&F in repair for 75mm PVC (SWR) bend any radius, complete all as specified and directed. |
| 47 | S&F in repair for PVC (SWR) 75mm bore junction single, ( Single T ), equal or unequal with access door, complete all as specified and directed. |
| 48 | S&F in repair for PVC (SWR) 110mm bore junction single, ( Single T ), equal or unequal with access door, complete all as specified and directed. |
| 49 | S&F in repair for 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed. |
| 50 | S&F in repair for 125/110mm dia stoneware Gully trap setting and jointing with cement mortar 1:1, complete all as specified and directed. |
| 51 | S&F in repair for stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stays to wall or roof, complete all as specified and directed. |
| 52 | M&L for soakage wells of size 2.20m dia and 3.40m depth excavation, in any type of soil, foundation in plain cement concrete 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in cement mortar 1:4, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats, complete all as specified and directed.Drawing No;- CEUZ/TD/1585/2021, sheet 1/4 to 4/4. |
| 53 | M&L for 75mm thick plain cement concrete, type D-2, 1:4:8, (using 40mm graded crushed stone aggregate) as in sub base, flooring, pavings etc finished rough to receive floor finishes/screed, complete all as specified and directed. |
| 54 | M&L for chequerred cement concrete tiles glossy finish coloured 30cmx30cmx25 mm thick pattern as approved by GE as in patches in floor set & jointed in neat cement slurry and pointed in coloured cement to match the tiles laid over creed bed or bedding layer of mortar 20mm thick for laying floor finishes in cement mortar 1:4, complete all as specified and directed. |
| 55 | Cutting into existing manholes for connecting new drains, pipe of size 150 mm dia pipe making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4), type B-1, smooth finished and reforming benching as required, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender