Tender For Provision Of Under Ground Sump Alongwith Fire Pump House For Paint And Pol Storehouse At maintenance of Karwar
Tender Value
69 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
25 days left
EMD
1.28 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Under Ground Sump Alongwith Fire Pump House For Paint And Pol Storehouse At maintenance of Karwar
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE 'A' PART-I BUILDING & STRUCTURES |
| 2 | (a) Design & Construction of Pump House Building in single story bldg as mentioned in Architectural drawings complete all as specified and shown on drawing . |
| 3 | (b) Design & Construction of Underground Sump for 1,00,000 Litre capacity with internal Dimension of 6.40 m X 6.40 m and height 3.00m including freeboard complete all as specified. |
| 4 | Total amount of Sch 'A' Part-II (EXTERNAL ELECTRIC SUPPLY) brought forward from Serial Page No. |
| 5 | Total amount of Sch 'A' Part-III (Internal (E/M) Services) brought forward from Serial Page No. |
| 6 | Total amount of Sch 'A' Part-III (INTERNAL ELECTRIC SUPPLY) brought forward from Serial Page No. |
| 7 | Sch 'A' Part- V - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only.) |
| 8 | Supply, install, connect, test and commissioning of Electrical Control Panel of cubicale construction floor mounted type, fabricated out of 2.00 mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process,cable alley, inter connection having switch gears and accessories mounted and internal wiring, earth terminals numbering etc, complete in all respetct sutable for operation on 415V, 3 Phase AC supply with enclousre protection class IP 42 as required with nessessary cables including following:- |
| 9 | INCOMING |
| 10 | (I) MCCB, AC 415 volts, 4- Pole, 250 Amps current rating, 36 KA rupturing capacity with adjustable (70% to 100%) thermal setting and fixed magnetic setting conforming to IS: 13947-II complete with connections to the bus-bars. - 01 No. |
| 11 | ii) Aluminium Bus-Bar of 300 Amps capacity with coloured PVC insulating sleeves, mounted on post insulatore, 1100 volt grade. |
| 12 | iii) Voltmeter 0 - 500 volts digital type, flush mounting with Selector Switch. - 01 Set |
| 13 | (iv) Ammeter 0 - 250 Amps digital type, flush mounted, with CTs and Selector Switch. - 01 Set |
| 14 | (v) Phase Indicator Lamps, LED type. - 01 Set |
| 15 | vi) Panel instrument fuses - 01 Set |
| 16 | OUTGOINGS |
| 17 | (a) Main fire pump |
| 18 | (i) MCCB, AC 415 volts, 4-Pole, 200 Amp rating, 16 KA rupturing capacity, with HRC Fuse 01Nos. with 50/75 HP fully automatic srar/delta starter with over load protetion, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation selector switch for loacal/remote auto/ manual / Off operation. |
| 19 | (b) Jockey pump |
| 20 | MCB TPN 63 Amp with HRC fuze Nos 01, with 15 Amp fully automatic srar/delta starter with over load protetion, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation selector switch for loacal/remote auto/ manual / Off operation. |
| 21 | (c) Diesel Engine Control |
| 22 | (i) Auto/Manual selector switch & 3 attempt starting device timers and relays as required push buttons start/stop in manual mode. |
| 23 | (ii) Indication lamp for high/low lub oil pressure of High water temp and engine on indication. |
| 24 | (ii) Battery charger suitable for 12V24V DC with boost and tickle selector switch, 0-30V DC voltmeter, 0-20 DC Ammeter. |
| 25 | (iv) All standerd relays and accessories for automatic operation of diesel engine. |
| 26 | (D) Designing, suppl, installation, testing and commisiiooning of system controller to control operation of Main Pump in sequence as per specification consisting of relays, timers, sensors, annuncation window for fault indication complete as per specification |
| 27 | (E) Indication system |
| 28 | The systen complete in all respect and consisting of the fwg as |
| 29 | (a) On/Off indication of main Electrical Fire pump and jockey pump. |
| 30 | (b) Auto/visual indication of operation of Main Electric, Diesel Fire pump and Jockey pump with reset push button. |
| 31 | (c) Pressure indication in Fire Fighting system |
| 32 | S&F in repairs flexible cord, 3 core, copper conductor 2.5 Sqmm complete all as specified & directed. Make : Finolex/Havells |
| 33 | Supply and installation, testing, commissioning of CI \\"Y\\" strainer 150 mm with nuts, bolts washers, gaskets complete as directed by Engineer in charge. |
| 34 | Supply, install, testing and commissioning of Gun metal air release valve 20 mm dia complete as directed by Engineer in charge. |
| 35 | Supply and fix Foot Valve conforming to IS 4038, 150 mm (6”) dia with nuts, bolts washers, gaskets complete as directed by Engineer in charge. |
| 36 | M&L for Solid raceway with cover cable tray of 200 mm, depth 50 mm and sheet thickness of 2mm, galvanized coating,Corrosion resistance with all accessories (bends,clamp,screws etc),complete installation on outer surface of building complete all as specified and directed. |
| 37 | Supply, Laying, jointing & testing of Ductile iron (DI), SS class pressure pipes with spigot or socket ends or flange ends, centrifugally cast, class K-9, 100 mm (4\\") dia with cement mortar lining in inner side as per IS:8329/ 2000 (latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining laid in trenches complete all as specified of following sizes:- Note : Excavation and earth work shall be measured and paid separately |
| 38 | M&L for cutting the cast iron pipe in position and making the connection with inserting new 'T' of size 100x100x100mm (for taking branch connection and making ring main) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender