Tender For Repair/ Replacement And Maintenance Of Misc E/M Equipments Including Building Security Lights With Fittings/Fixture And Allied Works Of E/M Including Acs, Deep Freezer, Refrigrator, Ceiling Fans, Exhaust Fans Etc At installation Satavahana
Tender Overview
Project Description
Tender for Repair/ Replacement And Maintenance Of Misc E/M Equipments Including Building Security Lights With Fittings/Fixture And Allied Works Of E/M Including Acs, Deep Freezer, Refrigrator, Ceiling Fans, Exhaust Fans Etc At installation Satavahana,Ins Virbahu, installation Circars,Ins Kalyani, Dockyard, Dolphin Park Area ,Dolphin Hills, Old And New Nsb, Naval Park, Amzari Park Area, ,Mmt,Sho Under Ge (Nb) Visakhapatnam
BOQ
| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc except light fitting. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 2 | Taking down unserviceable main switches, DBs, bus bars chambers, MCB/MCCB Enclosures any capacity including all fittings and fixtures such as MCBs, isolator, MCCBs, MCB protected Power socket etc and removing from site complete all as specified and directed. |
| 3 | Taking down unserviceable sub-main wiring (any numbers of cable) with rigid PVC/steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. |
| 4 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLSH (ISI marked) drawn through and including PVC casing caping (ISI marked) including Flush type metal GI / PVC boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLSH [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.) |
| 5 | All as per item No. 04 here in before but for one geyser/AC point with two runs of PVC insulated and unsheathed copper conductor cable of size 4.00 sqmm multistranded FRLSH (ISI marked) and 4.00 sqmm PVC insulated unsheathed solid copper conductor cable FRLSH (ISI marked) as earth lead complete ditto |
| 6 | S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. |
| 7 | S & F switch piano single pole one way 6 amp 240 volts, complete all as specified and as directed. |
| 8 | M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length) |
| 9 | M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLSH (ISI marked) copper cable drawn through and including surface PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLSH (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed.(Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length) |
| 10 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 1.5 sqmm complete all as specified and as directed. |
| 11 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 2.5 sqmm complete all as specified and as directed. |
| 12 | S & F repair three core, PVC insulated, sheathed, multistranded flexible copper conductor cable 1100 Volts [ISI marked ] of size 4.00 sqmm complete all as specified and as directed. |
| 13 | S & F in repair modular SRCD AC socket enclosure with plastic base frame complete with and including 3 pin plug and MCB SP 25 Amps, 240 volts, 10 KA complete all as specified and directed. |
| 14 | S&F MCB protected power socket (3P+N+E) with Steel Enclosure including 32 Amps MCB FP complete all as specified and as directed |
| 15 | S & F Vertical TPN DB double door,IP43 for provision of MCCB upto 250 A as incomer ,8 way with 200 A rating busbar complete all as specified and as directed. |
| 16 | Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Havell's cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer's) |
| 17 | upply, fixing, commissioning and testing MCB TP 63 Amps, 415 Volts, 10KA, C curve complete all as specified and as directed (Make: Havell's cat part No. DHMGCTPF063 or equivalent make as per List of Manufacturer's) |
| 18 | S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 16 KA, 3 Pole, 100 Amps Capacity complete all as specified and as directed. |
| 19 | S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 16 KA, 4 Pole, 100 Amps Capacity complete all as specified and as directed. |
| 20 | S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 125 Amps Capacity complete all as specified and as directed. |
| 21 | S & F MCCB with fixed thermal and fixed magnetic release ,415 Volt, 25 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed. |
| 22 | S & F MCCB with fixed thermal and fixed magnetic release , 415 Volt, 25 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed. |
| 23 | S & F MCCB with fixed thermal and fixed magnetic release 415 Volt, 25 KA, 4 Pole, 250 Amps Capacity complete all as specified and as directed. |
| 24 | S & F in repair MCCB Spreaders, 4 pole suitable upto 250 Amps complete all as specified and as directed. |
| 25 | S & F in repair MCCB Spreaders, 3 pole suitable upto 250 Amps complete all as specified and as directed. |
| 26 | S & F MCCB enclosure IP 43 with solid neutral link suitable for 4 pole MCCBs complete and making good disturbed surfaces complete all as specified and as directed. Note :- MCCB will be measured and paid under respective item |
| 27 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 28 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 29 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 30 | Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm 4 core, fixing along the poles or passing through pipes or laid under floor of through walls etc jointing and testing including taking out/down existing cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately) |
| 31 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 32 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed. |
| 33 | Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 34 | Supply and laying well burnt bricks, fly ash bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed. |
| 35 | M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed.(Note: Thickness after punning down shall be measured for payment) |
| 36 | S & F in repair IP 66 junction box made of impact resistance polycarbonate & heat resistant materials of size 200x160x98mm mm, dust proof, water tight, light weight, acid resistant, corrotion proof insulated and shock proof, fire retardant, self extinguishing, helogen & silica free non toxic material, UV resistant with internally embedded gasket and fitted with required terminals alongwith type test certificate and veryfied by glow-wire test in accordance with IEC60695-2-11 complete all as specified and directed directed. (Make : HENSEL, Cat No : KF9255 or equivalent model of make as per list of manufacturer) |
| 37 | S & F in repair LED outdoor Security light fittings, Min IP 65 rated, aluminium die cast housing with powder coating, pole mounted, 36 Watt, Lumen ≥ 3600, Luminous afficacy ≥ 100 Lum/Watt, CCT:WW/NW/CW, CRI > 70 Ra, 4KV surge Protection with open and short circuit protections as per IS: 10322 with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. |
| 38 | S&F in repair recessed mounted 36 Watt LED (CCT-warm white/Natural white/Cool white) panel light 2x2 feet, ultra slim design, 230 volts, 50 Hz with CRCA sheet housing precoated white colour and high quality diffuser for uniform light and high efficiency with separate replaceable electronic driver including lamp complete all as specified. Make- Havells Cat part No-LHEBAEP7IW1W036 or equivelant of make as per list of manufacture |
| 39 | S & F in repair LED outdoor Flood light fittings,50 Watt, 230 Volts AC , made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. |
| 40 | S & F in repair LED outdoor Flood light fittings, 70 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. |
| 41 | S & F in repair LED outdoor Flood light fittings, 100 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. |
| 42 | S & F in repair LED outdoor Flood light fittings, 150 Watt, 230 Volts AC ,made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. |
| 43 | S & F in repair circular highbay LED light fittings, 200 Watt, 230 Volts AC with toughened glass, upto150 lm/W with10 kV SPD with IP66 protection with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. |
| 44 | S & F in repair LED light fittings, 1x4', 40 Watt, 230 Volts AC with high performance, commercial grade solution industrial application with impact and corrosion resistant, IP65 rating complete with driver and lamp and with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including lamp complete all as specified and directed. |
| 45 | S & F in repair 25 Watt, 230 Volts AC Post Top Lantern, outdoor type with decorative post top for 360 Degree indirect light, IP 65 protection with impact and corrosion reisitant complete with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed. |
| 46 | S & F in repair LED bamboo Bollard with robust design and efficient light distribution of minimum 08 watt 230 watt volts AC outdoor type with decorative light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. Make:- Havells cat part No BAMBOOBLS8WLED830PSYMTOPC or equivalent in CG/Philips/Bajaj |
| 47 | S & F in repair 10 Watt, 230 Volts AC, Inverted Pyramid Tripod type LED Bollard light fittings with soft 360 light distribution, Min IP 65 rated, outdoor type with decorative light with impact and corrosion resistant with driver and lamp and with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed. |
| 48 | S & F in repair 10 Watt, 230 Volts AC, LED Bollard light fittings, efficient light distribution, Min IP 65 rated, outdoor type with decorative light with impact and corrosion resistant with driver and lamp and with all accessories and connecting up with twin core twisted copper conductor cable of suitable size including lamp and making good disturbed surfaces complete all as specified and directed. |
| 49 | S & F in repair 40mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed. |
| 50 | S & F in repair 50mm bore, Steel water tubing, galvanised, medium grade with all fittings laid in trenches etc complete all as specified and directed. |
| 51 | S & F in repair Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed. |
| 52 | M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. |
| 53 | S & F in repair starter with push button switch with 1NO+1NC complete working on AC supply upto 16 Amp capacity complete all as specified and directed. Please Enable Macros to View BoQ information |
| 54 | S & F in repair starter with push button switch with 1NO+1NC complete working on AC supply upto 16 Amp capacity complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender