Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #57484073

Tender For Provn Of Sub Guard Room With Attach Toilet And Bathroom For Guard Near Govt Md Accn At Panitola Military Station Under Ge Dinjan No.2

Issued by Statutory Bodies & Commissions/Committees · Tinsukia, Assam
Tender Value
41.50 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
20 days left
EMD
83000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Sub Guard Room With Attach Toilet And Bathroom For Guard Near Govt Md Accn At Panitola Military Station Under Ge Dinjan No.2

BOQ

Name of Work:- PROVN OF SUB GUARD ROOM WITH ATTACH TOILET AND BATHROOM FOR GUARD NEAR GOVT MD ACCN AT PANITOLA MILITARY STATION UNDER GE DINJAN NO.2
Sl. No. Item Description
1Surface excavation n.exc 30 cm deep and averaging 15 cm deep geeting out in soft/loose soil complete all as specified and directed by Engineer in Charge.
2Excavating in trenches, n. exc 1.5 m wide and n. exc 1.5 m in depth; for foundation, etc. and getting out in soft/loose soil complete all as specified and directed by Engineer in Charge.
3M&L for PCC (1:4:8) type D2 (using 40mm crushed and graded stone aggregate) as in foundaion and mass filling complete all as specified and directed by Engineer in Charge.
4Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; complete all as specified and directed by Engineer in Charge.
5Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in columns, posts, struts etc. complete all as specified and directed by Engineer in Charge.
6M & L pre cast RCC (1:2:4) type B-1 using 20 mm nominal size crushed and graded stone aggregate in cover slabs or of similar items including necessary cutting, form work etc.cement complete all as specified and directed by Engineer in Charge.
7Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in beams, lintels, etc.; complete all as specified and directed by Engineer in Charge.
8Providing and laying for reinforced cement concrete type B-1, 1:2:4 (using 20mm nominal size crushed and graded stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like ; complete all as specified and directed by Engineer in Charge.
9M&L for cement concrete Type C-2, 1:3:6 (using 40mm nominal size crushed and graded stone aggregate) in foundations filling and mass concrete as in manhole etc. complete all as specified and directed by Engineer in Charge.
10M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished flat surface of concrete complete all as specified and directed by Engineer in Charge.
11M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished flat surface of concrete complete all as specified and directed by Engineer in Charge.
12M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. in rough finished flat surface of concrete complete all as specified and directed by Engineer in Charge.
13M & L for formwork to soffits of suspended slabs as roof slabs, floor slabs, landings amd similar work not exceeding 200mm thick in rough finished surfaces of concrete complete all as specified and directed by Engineer in Charge.
14M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n. exc. 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work in rough finished flat surface of concrete complete all as specified and directed by Engineer in Charge.
15M & L for deformed TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer in Charge.
16M & L for deformed TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer in Charge.
17Providing and laying 75mm thick cement concrete type C-2, 1:3:6 (using 40mm nominal size crushed and graded stone aggregate) and finished even and fair in base concrete complete all as specified and directed by Engineer in Charge.
18Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, complete all as specified and directed by Engineer in Charge.
19Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in Skriting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick rendering in cement mortar (CM) 1:4, complete all as specified and directed by Engineer in Charge.
20Providing and laying skid/non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick screed bed in cement mortar (CM) 1:6, complete all as specified and directed by Engineer in Charge.
21Providing and laying coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.08 sqm but not exceeding 0.15 sqm, in skrting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match tile colour over 15 mm thick rendering in cement mortar (CM) 1:4, complete all as specified and directed by Engineer in Charge.
22M & L full brick work with Old Size Cement boned Bricks of class designation 75, straight or curved on plan exc. 6m mean radius built in CM (1:6) complete all as specified and directed by Engineer in Charge..
23M & L for half brick work with old size Cement bonded bricks of CD 75, straight or curved on plan exc. 6m mean radius, built in cement mortar 1:4 complete all as specified and directed by Engineer in Charge.
24Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer in Charge.
25Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer in Charge.
26M & L 15mm thick plastering on brick/stone/concrete surafces of wall in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge..
27M & L 15mm thick plastering on brick/stone/concrete surafces of wall in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
28M & L 15mm thick screed bed on brick/stone/concrete surafces of roof surfaces in cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
29M&L 10 mm thick plastering on brick/ stone/ concrete surfaces of ceiling in cement mortar (1:3) finished even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge..
30Supply only water proofing compound complete all as specified and directed by Engineer in Charge.
31M & L for Broken stone or boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer in Charge.
32S & F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; and similar work conforming to Fe. 290, Gde-E-165 complete all as specified and directed by Engineer in Charge.
33S & F of 1.6mm thk MS plate as in wall clading of steel gates with necessary arrangement and similar work complete all as specified and directed by Engineer in Charge.
34S & F for Factory made single extruded WPC (wood polymer composite) solid door/ window / ceosetory windows & other frames / chowkhat of size 50x125 mm comprising of virgin PVC polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having maximum frame density of 750 kg / cum, screw withdrawel strength of 2200 N (Face) & 1100 N (Edge), minimum comprssive strength of 58 N / mm², Modules of elasticity 900 N / mm² and resistance to spread of flame of class A category with property of beeing termite / borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast / lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast / lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door / window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
35S & F for Factory made single extruded WPC (wood polymer composite) solid door/ window / ceosetory windows & other frames / chowkhat of size 65x150 mm comprising of virgin PVC polymer of K value 58-60 (suspension Grade), calcium carbonate and natural fibers (wood power / rice husk /wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having maximum frame density of 750 kg / cum, screw withdrawel strength of 2200 N (Face) & 1100 N (Edge), minimum comprssive strength of 58 N / mm², Modules of elasticity 900 N / mm² and resistance to spread of flame of class A category with property of beeing termite / borer proof, water / moisture proof and fire retardant and fixed in position with MS hold fast / lugs / SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast / lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door / window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
36S&F 25 mm thick Flush shutters, solid core construction, with block board core with decorative face veneers withlipping on both sides, complete all as specified and directed by Engineer in Charge..
37Supply and fixing of door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panel door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
38Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs.The frame shall be covered with fiber glass from all sides.M.S. stay shall be provided at the bottom to steady theframe., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
39Supply and fixing of door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) flush door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
40Providing and fixing factory made uPVC colour casement windows & ventilator (Outward /inward) with hinges system made of extruded profiles. Profiles of frames 60mm X 58mm and sash (style and rail) 60mm X 78 mm will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc.. making arrangement for fixing of hardware, EPDM gasket, 1.2+0.2.mm thick galvanized steel profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, all complete and as directed, (Glazing, hardware hinges and fitting, EPDM rubber gasketetc. to be paid separately.)Note:-Each member of window to be measured separately with clear length.
41Providing and fixing factory made uPVC colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.)(A) Area exceeding 1.00 sqm but not exceeding 2.00 sqm each
42Providing and fixing factory made uPVC colour casement (Openable) window made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of SS wiremesh and includes all other connected accessories Net opening will be measured for payment purpose.)(A) Area exceeding 1.00 sqm but not exceeding 2.00 sqm each
43S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane, complete all as specified and directed by Engineer in Charge.
44S&F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq.m in each pane, complete all as specified and directed by Engineer in Charge.
45S&F 75 mm size of butt hinges stainless steel, complete in all respect complete all as specified and directed by Engineer in Charge.
46S&F 100 mm size of mild steel butt hinges ISI marked, complete all as specified and directed by Engineer in Charge.
47Providing and laying for cement concrete in coping, hold fasts using type B-1, 1:2:4 (using 20 mm nominal size crushed and graded stone aggregate) or of similar type of work including necessary formwork complete all as specified and directed by Engineer in Charge.
48M&L for PCC 1:2:4 type B 1 (using 20mm nominal size crushed and graded stone aggregate) as in surface channels & drains complete all as specified and directed by Engineer in Charge.
49M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer in Charge.
50M&L for any colour of granite stone without white spots Granite stone slab 17 to 19 mm thick, as in floor, dado, steps, laid over and including screed bed 15 mm thick in cement mortar (CM) 1:6, jointed and pointed with white cement mixed with pigment to match the shade of stone including cuttingl rubbing and polishing surface, including cutting for wash hand basin, sink, gas pipe hole etc., to the entire satisfaction of the Engineer-in-Charge, complete all as specified and directed by Engineer in Charge.
51S & F of roof treatment with the following specification:-(a)Applying cement slurry over concrete surfaces @3kg/sqm. (b)Rendring 15mm thick in cement mortar (1:4) mixed with water proffing compound as per manufactures instruction on cleaned concrete surfaces of roof and finishing the surfaces fair and even including curing the plastered surfaces for 7 days by ponding of water over the roof, (leveling course).(c) Applying evenly one coat of cold bituminous primer conforming to [email protected] liter per square metre on the cleaned plastered surfaces(d) Applying evernly one coat of blown hot bitumen of grade 85/25@ 1.20 Kg per square metre on primed surfaces.(e) Applying a layer of APP based polymeric membrane, 3mm thick (minimum) weighing 3.50 Kg per square metre reinforces) with polyster non woven fabric wighing not less than 160 gms per square metre by torch application. The overlap shall be not less than 100mm on transverese direction and 75mm on longitudinal direction and sealing overlsaps.(f) Applying evenly one coat of aluminium paint @ 0.10 litre per square metre over the APP based polymeric membrane.
52S & F CPVC pipes SDR 11 and plain CPVC SDR-11 fittings on walls/ceiling or laying in floors/concealed in wall of size 20mm outer dia complete all as specified and directed by Engineer in Charge..
53S & F CPVC pipes SDR 11 and plain CPVC SDR-11 fittings on walls/ceiling or laying in floors/concealed in wall of size 25mm outer dia complete all as specified and directed by Engineer in Charge.
54S&F in repair 20 mm bore of Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed, complete in all respect as specified and directed.
55S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width aperture 1.40 mm and fixed with stainless steel wire staples fixing withbeads, complete all as specified and directed by Engineer in Charge.
56S&F aluminium anodised, barrel tower bolt of extruded section 200 mm long, complete all as specified and directed by Engineer in Charge.
57S&F Aluminium handle cast type anodised 125 mm, complete all as specified and directed by Engineer in Charge.
58S&F aluminium anodised sliding door bolts with hasp and staple (boilt type) 16 mm dia bolt, 250 mm long, with and including a minium of 6 bolts and nuts four on bolt plate and two on staple plate, complete all as specified and directed by Engineer in Charge.
59S&F mild steel 300 mm, ordinary rat tail rod pattern springs, including roller and roller plate, complete all as specified and directed by Engineer in Charge.
60S&F PVC coloured insulated over MS pipe 20 mm dia curtain rod with fixing bracket, stops, rollers etc. complete all as specified and directed by Engineer in Charge.
61S & F of 4mm thk of size 600mmX 450mm bevelled edge mirror of selected quality decorative type mounted on 6mm commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed by Engineer in Charge.
62S&F three layered white in colour rotational moulded made out from LLDPE material water storage tanks of capacity 1000 ltr (cylindrical vertical with closed top) including three tank nipples of 20 mm nominal bore dia hoisted and fixed in position including dismantling/ taking down all as specified in SSR part I, complete all as specified and directed by Engineer in Charge.
63S&F PTMT ball valve high pressure 20 mm bore with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe, complete all as specified and directed by Engineer in Charge.
64S & F of 15mm bore concealed long neck , CP finished stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engineer in Charge.
65S&F of vitreous chinaware sqatting pan of size 580 x 440 mm, 'ORISSA PATTERN' with new PVC 'P' or 'S' trap bedded in cement concrete (excluding flushing cistern and flush pipe) with integral foot rests, complete all as specified and directed by Engineer in Charge.
66S&F of PVC valveless, syphonic action type, low level dual flush cistern 10 ltr capacity, white, wtih inlet, ball valve, float and handle including brackets & flush pipe of polyethylene for low or high level cistern of required height of high density PVC, 32 mm dia pipe, complete all as specified and directed by Engineer in Charge.
67S&F PVC connection 15 mm size with PTMT nuts of length 450 mm, complete in all respect complete all as specified and directed by Engineer in Charge.
68S&F in repairs 15 mm bore fancy type CP finished angle valves, cast copper alloy, screwed down, high pre-ssure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer in Charge.
69S&F in repairs long body Bib taps of 15 mm bore, fancy type CP finish cast copper alloy with crutch handle, screwed down, screwed for iron pipes, complete all as specified and directed by Engineer in Charge.
70S&F in repairs short body Bib taps of 15 mm bore, fancy type CP finish cast copper alloy with crutch handle, screwed down, screwed for iron pipes, complete all as specified and directed by Engineer in Charge.
71S&F in repair for 15 mm bore pipe brass chromium plated (CP) shower rose 125 mm size, fixed to iron pipe, complete all as specified and directed by Engineer in Charge.
72S&F Tubular towel rail, 20 mm dia, D type, 60 cm long between flanges cast copper alloy, chromium plated finish, complete all as specified and directed by Engineer in Charge.
73S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long, complete all as specified and directed by Engineer in Charge.
74S&F of wash hand basins (WHB), vitreous china of size 550x400 mm (flat back or angle back type) with pedastal stand, including cutting for and pinning in ends of brackets over new angle iron erecting stand embedded in PCC (1:2:4) block including 32 mm dia bore waste fittings cast copper alloy chromium plated with long screwed shanks and flynuts flange and beded in redlead cement, PVC waste pipe including 15 mm bore dia fancy type CP finish pillar tap, cast copper alloy with capstand heads, screw down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screw for iron pipes complete all as specified and directed by Engineer in Charge.
75S&F 75 mm dia of outlet, PVC (SWR) nahani trap, plain with SS grating of size 150mmX150mm, 0.75mm thick openable at center including jointing with solvent cement, complete all as specified and directed by Engineer in Charge.
76S & F PVC (SWR) pipes single socketed in any length with rubber ring jointslaying in trenches 150 mm bore complete all as specified and directed by Engineer in Charge.
77S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm bore including necessary MS pipe clamp, complete all as specified and directed by Engineer in Charge.
78S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore including necessary MS pipe clamp, complete all as specified and directed by Engineer in Charge.
79S&F PVC (SWR) pipes single sockedted in any length with rubber ring joints laying in trenches 110 mm bore, complete all as specified and directed by Engineer in Charge.
80S&F PVC (SWR) pipes single sockedted in any length with rubber ring joints laying in trenches 75 mm bore, complete all as specified and directed by Engineer in Charge.
81S&F PVC (SWR) single (single 'T') equal or unequal 110mm bore pipe with access door, complete all as specified and directed by Engineer in Charge.
82S&F PVC (SWR) single (single 'T') equal or unequal 75mm bore pipe with access door, complete all as specified and directed by Engineer in Charge.
83S&F PVC (SWR) bends any radius 110 mm bore, complete all as specified and directed by Engineer in Charge.
84S&F PVC (SWR) bends any radius 75 mm bore, complete all as specified and directed by Engineer in Charge.
85S&F PVC (SWR) vent cowl 110 mm dia bore, complete all as specified and directed by Engineer in Charge.
86S&F PVC (SWR) vent cowl 75 mm dia bore, complete all as specified and directed by Engineer in Charge.
87Supply and fixed unplasticised PVC (SWR) Gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer in Charge.
88M&L for plinth protection or in foot path of 75 mm thick of cement concrete using type C-1, 1:3:6 (using 20 mm nominal size crushed and graded stone aggregate) in alternate penals and finished fair and even complete all as specified and directed by Engineer in Charge.
89S & F of polythene film black 150micron complete all as specified and directed by Engineer in Charge.
90M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer in Charge.
91M & L for two coat water based premium acrylic smooth exterior emulsion of approved colour with silicon additive and color stay Techonology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/litre as per the LEEDS specifieecations, Anti Algal properties in two coats @ 1.79 ltr (Undiluted)/10 Sqm with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow spreed of min 1 ltr per minute having a pressure of 3300 PSI Allow 6-8 hrs to dry the surface in both coats of paint complete all as specified and directed by Engineer in Charge.Note : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.
92M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the newly plastered surfaces of wall to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) Masking of waindow/doors during spray painting using polythine film will be included (d) Cleaning and clearing site of paint, mats etc included.
93M & L for waterproof cement based putty @ 1 Kg (undiluted) per sq mtr of average thickness 1mm over the newly plastered surfaces of ceiling to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanicsm) having RPM not less than 1500, sanding pad of 240 grit or above to make the surface free from dust etc by skilled labour as per following steps : -Step 1 : Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 Kg putty per minute.Step 2 : Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a max pressure 3300 PSIStep 3 : Allow 6-8 hrs time to dry the putty surfaceNote : (a) The work pertaining to periodical services and water proofing shall be executed as per manufacturer instructions i.e. Paint, Distemper, Putty etc is proposed to be used by the contractor and approved by Engr-in-Charge.(b) Cost of Scafolding upto 10 mtr height of building is included in this item.(c) Masking of waindow/doors during spray painting using polythine film will be included (d) Cleaning and clearing site of paint, mats etc included.
94S&F rolled section as in framing for door/vent/CB/chowkhats/water staging , wind tie and the like using angle, tee, hollow tubes etc., cleat and connecting plates complete (Butt hinges shall be measured and paid for separately) using Fe 410-W (Gde-E-250) quality \\"A\\" complete all as specified and directed by Engineer in Charge.
95M & L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and directed by Engineer in Charge.
96M & L for treating the top surface of filled earth at the rate of 5 litres of emulsion per suare metre of surface complete all as specified and directed by Engineer in Charge.
97M & L for treating the soil under plinth protection at the rate of 5 litres of emulsion per sqare metre of surface area complete all as specified and directed by Engineer in Charge.
98M & L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer in Charge.
99M & L for applying Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, at the junction of Perimeter of the building and every 3 mtr in the lateral dimension complete all as specified and directed by Engineer in Charge.
100M & L brick work with sub-class \\"B\\" old size bricks of class designation 75, straight or curved on plan exc. 6m mean radius built in CM (1:6) complete in all respect complete all as specified and directed by Engineer in Charge.
101M & L brick work sub class B, class designation 75 old size bricks, straight or curved on plan exceeding 6 m mean radius built in CM 1:4 complete in all respect complete all as specified and directed by Engineer in Charge.
102S & F for 60mm thick coloured,pre coated interlocking or without interlocking paver block of any shape and size confirming to IS 15658/1237 with upto date amendments, M-35 Grade with grey cement with pigment laid over fine river bed sand complete all as specified and directed by Engineer in Charge..(Note:- River bed sand shall be measured and paid separately). Sample as approved by GE.
103M&L for preparaing new un decorated plastered or unplastered surface of wall and apply three coats of white wash complete all as specified and directed by Engineer in Charge.
104M&L Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in Type A-1 1:1.5:3 cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2m dia and 3.0m depth complete all as specified and directed by Engineer in Charge..
105M&L for Brick Septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC Type A-1 1:1.5:3 Mix Baffle walls and Roof Slab including beams etc with Vent shaft,manhole openings with cover connection etc for 10 users capacity all as per Drawing available with sub division complete all as specified and directed by Engineer in Charge.
106M & L for 150mm bore pipe for concrete bed in PCC 1:4:8 type D 2 using 40mm nominal size crushed and graded stone aggregate to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested in complete all as specified and directed by Engineer in Charge.
107M & L for Point wiring for one light point controlled by one switch with 1.5 sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded copper cable confirming to IS:694(2010) using approved colour code for phase and neutral as per IS code drawn through non metallic PVC rigid concealed conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I ( ISI marked) including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories suitable for modular type fitment,provision for fixing of modular flush boxes of appropriate sizeand dimensions for fixing of piano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 1.5 sqmm multi stranded copper conductor cable (green color) as continous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engr-in-Charge.
108Description all as per item no.107 here in before but for ceiling fan / Exhaust fan point controlled by one 5 amp switch
109Description all as per item no.107 here in before but for 05 amp socket outlets point controlled by one switch on Independent board complete all as specified and directed.
110Description all as per item no.107 here in before but for 05 amp socket outlets point controlled by one switch on same board with other switches complete all as specified and directed.
111Description all as per item no.107 here in before but for 15 amp socket outlets point controlled by one switch on Independent socket outlet using 2.5sqmm PVC insulated and unsheathed fire retardant low smoke and halogen(FR-LSH) copper conductor single core multi stranded copper cable confirming to IS:694(2010) using approved colour code for phase and neutral as per IS code as per IS code drawn through non metallic PVC rigid concealed conduit heavy mechanical stress (HMS) grade in accordance with IS:9537 (Part 3) having wall thickness not less than 2.0 mm thick and minimum 20 mm external dia but shall be increased as per actual site requirement in accordance with clause No 19.125 of SSR Part I ( ISI marked) including conduit accessories like bends, tees, junction boxes etc fixed concealed with all accessories suitable for modular type fitment,provision for fixing of modular flush boxes of appropriate size and dimensions for fixing of piano switches/sockets/regulator etc including PVC insulated and unsheathed FRLSH 2.5 sqmm multi stranded copper conductor cable (green color) as continous earth lead wire connected to common earth and earth dolly complete all as specified and directed by Engr-in-Charge.
112M & L for Ceiling rose, 2 to 3 terminal PVC/ polycarbonate, isolated body type suitable for AC 230 volts complete all as specified.
113M & L for module cover plate with frame as per site requirement for following module complete all as specified and as directed.
114Description all as per item no.113 here in before but 1 module
115Description all as per item no.113 here in before but 2 module
116Description all as per item no.113 here in before but 3 module
117Description all as per item no.113 here in before but 4 module
118Description all as per item no.113 here in before but 6 module
119Description all as per item no.113 here in before but 8 module
120M & L for Modular metal Flush box as per site requirement.
121Description all as per item no.120 here in before but 1/2 module
122Description all as per item no.120 here in before but 3 module
123Description all as per item no.120 here in before but 4 module
124Description all as per item no.120 here in before but 6 module
125Description all as per item no.120 here in before but 8 module
126M & L for modular switch 1 way 5/6 Amp 1 Module, 240 volts complete all as specified and as directed.
127M & L for Modular Switch 1 way 16/20 Amp 1 Module, 240 volts complete all as specified and as directed.
128M &L for Modular Socket 6A 2/3 Pin universal 2 module , complete all as specified and as directed.
129M &L for Modular Socket 16A/ 6A 2/3 Pin combined 2 module ,complete all as specified and as directed.
130M &L for Modular fan step regulator 120 watt 2 module ,complete all as specified and as directed.
131Supply and fix Lamp holder, white Polycarbonate body, with back plate suitable for batten fittings fixed in position & connecting complete.
132S&F emergency inverter built LED lamp 10/12 watt cap ,lumen output not less than 1100 lumen estimated life span of 25,000 hrs ,IP 20,CRI-80, B22/E27/E14 complete all as specified and directed
133Supply and fix energy efficient 20 watt (4.0 feet) LED integrated batten type luminaires suitable for wall or ceiling mounting with built in LED Chip & integral LED driver 20 watt, Aluminium channel housing & Polycarbonate diffuser of length 1200 mm (approx.),Color temperature 6500 K or as directed, CRI between 80-85,Low THD, PF-0.90(mimium), IP-20, efficacy not less than 120 lumen/watt or total lumen output not less than 2400 lumen per 20 watt, operating range 200-270V ,surge protection of 2 kV, over voltage protection and other safety tests as per IS 15885 Part-2/Part-3, estimated life span of 25,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge. Note: (i) LED fitting shall be provided for 3 years warranty.
134Supply and fix energy efficient 10/12 watt (2.0 feet) LED integrated batten type luminaires mirror type suitable for wall or ceiling mounting with built in LED Chip & integral LED driver 10/12 watt, Aluminium channel housing & Polycarbonate diffuser of length 600 mm (approx.), Color temperature 6500 K or as directed, CRI between 80-85, Low THD, PF-0.90(mimium), efficacy not less than 120 lumen/watt or total lumen output not less than 1200 lumen per 10 watt, operating range 200-270V, surge protection of 2 kV, estimated life span of 25,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge. Note : (i) LED fitting shall be provided for 3 years warranty.
135Supply and fix Exhaust Fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz,RPM 2500, Copper winding of sweep 200 mm,03 nos blades,with guard,opaque finish Aerodynamically designed & Blanced Blades,100 CFM air delivery, Noise level less than 40db including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose, including outside louvers with proper cutting of hole suitable for external dia of exhaust fan and grouting of anchor fastner/ rag bolts and nuts etc alongwith necessary fixing arrangment and making good to disturbed surface by using cement mortar 1:3 complete all as specified and directed .
136Supply and fixing 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, down rod/down rod as per height available at site , 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.0, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply etc, complete with fixing arrangement anchor tpe fastener hook including connection with 1.5 sqmm mutistrand copper conductor flexible wire from ceiling rose to fan drawn through PVC flexible conduit complete all as specified and directed.
137Supply and fix distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with appropriate Amps rated copper busbar, neutral bar,internal earth bar and cable ties for cable management,reversible door forIP 43 & IP 54,IK 09 impact resistance, single pole and neutral 250 Volts, flush to wall including chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. DB shall be designed with provision for MCB SPN as incomer & MCB SP as outgoing as per requirement. Cost of the DBs will be without MCBs complete all as specified and as directed Note : Rates are inclusive for flush(Concealed ) mounting of DB SPN.Note : The MCB shall be of same make as per distribution board
138Supply and fixing 240V,10 KA 'C' curve miniature circuit breaker (MCB) single pole of current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning all as specified and directed.
139Supply and fixing 240V,10 KA 'C' curve miniature circuit breaker (MCB) single pole of current carrying capacity 40 Amps, in the MCB DB complete with connection testing and commissioning all as specified and directed.
140Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single pole and neutral and current carrying capacity 32 Amps, in the MCB DB complete with connection testing and commissioning all as specified and directed.
141M & L for Earthing complete with GI earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to GI wire 4mm dia as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal(weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI earth wire protection pipe 15mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I , connected to earthing testing point and testing on completion complete all as specified and directed by Engr-in-charge.
142M & L for GI wire 4mm dia and fixing with proper clamp, saddles, nuts bolts, washers etc. properly and connected to pole complete all as specified and directed.
143Supply and fixing GI Pipe light grade 15mm bore for protection of GI earth lead complete with all fittings complete all as specified and as directed.
144Supply and fixing LED building Security Light fitting 35 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws with IP 65/66 protection, complete all as specified and as directed by Engr-in-charge.
145Supply and fixing Bracket made out of GI light grade pipe of size 40 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 50mm x 50mm and 04 sets of nuts, bolts and washers including painting with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer complete all as specified and as directed by Engr-in-charge.
146Supply and fixing, water heater storage (Geyser), 25 Litres capacity, 5 star rated ,vertical type wall mounted, 230 volts, AC, 50Hz, single phase, made out of CRCA outer body, stainless steel storage tank and titanium enamelled heating element wattage minimum -2kw, high pressure withstand capacity 8 Bar, inner surface of storage tank should be coated with a layer of anti-corrosive material/Glass line coating/porcelain enamel coating/titanium enamel coating for extreme protection, rust proof, non-corrosive including fusible plug, digital thermostat, pressure valve, FRLS cable, poly-urethane-foam (PUF) should be min 30mm thickness,450 mm long (cold water pipe) with copper cuch and 15mm 450 mm long armourd pipe (hot water pipe ) etc. complete including making necessary electrical and water connections with 2.5 sqmm 3 core copper (multistranded) cable with top indicator plug top 15 amp from geyser connnection to socket incl hold fast for fixing of new geyser and writing the MES No etc complete as specified and directed by Engr in charge.
147Supply and spreading fine river sand in trenches for cushioning of under ground cable/filling cable ducts all as directed by Engr-in-Charge at site Note : Only punned thickness shall be measured for payment purpose
148Supply and laying burnt brick sub class ‘B’ of standard size laid in trenches as protection to cables complete all as specified and as directed by Engineer-in-charge.
149Material & Labour for boring of holes under road, pavement, hard standing by trenchless technology technique for 40-80 mm dia pipe complete all as specified and as directed by Engineer-in-charge.
150Material & Labour for light grade galvanized pipe ISI marked laid in trenches, under road or fixing on wall/pole/ crossing nallah etc for cable protection of size 40 mm bore dia complete all as specified and as directed by Engineer-in-charge.
151Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power UG cables (heavy duty) 1100 Volts grade with stranded aluminium conductor confirming to relevant IS specifcations of size 16 Sq mm 2 core complete all as specified and as directed.
152Cutting existing steel tubing for alteration or addition (each cut measured ) bore of pipe 40 mm / 50 mm /80mm complete all as specified and directed by Engineer-in-charge.
153Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector) of 20/25mm dia pipe complete all as specified and as directed by Engineer-in-charge.
154Material and Labour for GI pipe 20 mm dia bore, medium grade with all fittings such as Sockets, Reducers, Unions, Tees, Nipples, Bends etc laid in trenches/walls/floors complete all as specified and directed by Engineer-in-Charge.
155Description all as per serial item No.154 here-in-before but of size 25mm bore complete all as specified and directed.
156Supply and fixing Gun Metal gate valve with iron wheel head, suitable for 25 mm bore pipes, screwed both ends for iron pipe or for union complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57484073
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 41.50 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Sub Guard Room With Attach Toilet And Bathroom For Guard Near Govt Md Accn At Panitola Military Station Under Ge Dinjan No.2
Basic Detail
Tender No 8984/E8
Bidding Type Tender
Location
City Tinsukia
State Assam
Key Dates
Publish Date 11 Sep 2026
Submission Date 03 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 41.50 Lakhs
Tender Fee 500
EMD 83000
Exemption Available
Document List
0cec9702-1376-4f9e-be12-175867749d20.html
BOQ_884049.xls
Tender.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

0cec9702-1376-4f9e-be12-175867749d20.html

xls

BOQ_884049.xls

pdf

Tender.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders