Tender for Upgradation Of 03 Nos Operation Theatres As Ductless Modular Ots In Pediatrics Surgery At Smgs Hospital, Jammu
BOQ
| Sl. No. | Item Description |
| 1 | A) Ductless Modular OT no. 1 of size 20’ X 20’ X 11’ in Paediatrics Surgery OT Complex along with allied works at Govt SMGS Hospital, Jammu.PPGI WALL PANELProviding and Fixing/Installation Pre-fabricated PPGI on both sides Puff panel with 50mm thickness wall panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside to became soundproof & with anti-bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler. Job also involves painting of at least 2 coats of antibacterial paint on all the walls of OT. Job also includes supply and fixing of the accessories for the panels like L angle, c flashing, screw, t-section support etc. Job includes cost of material and labour charges |
| 2 | PPGI FALSE CEILINGProviding and Fixing/Installation Pre-fabricated PPGI on both sides Puff panel with 50mm thickness false ceiling panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside to became soundproof & with anti-bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler. Job also involves painting of at least 2 coats of antibacterial paint on all the walls of OT. Job also includes supply and fixing of the accessories for the panels like L angle, c flashing, screw, t-section support etc. Job includes cost of material and labour charges |
| 3 | ANTI-STATIC VINYL FLOORING. Providing & fixing 3 mm thick Vinyl flooring with carbon granules colour, scratch resistant, fire resistant, chemical resistant, slip resistant, anti-fungi & bacterial growth, electrical resistant. Installation: The flooring would be installed on a smooth, clean sub floor which should be free from any undulation. Resistant to Mechanical stress and dynamic loads. It should be washable. Job includes cost of material and labour charges. |
| 4 | ALUMINIUM COVING Aluminium coving with PVC coating and Dimensions of minimum 50mm radius and length as per site requirement. Aluminium 6063 backing angle fixed with screws and coving clips into place Sealing Coving at either edge with proprietary sealant. Job includes cost of material and labour charges. |
| 5 | VINYL COVINGVinyl coving with Dimensions of minimum 50 mm radius and length as per site requirement. Material Aluminium 6063 backing angle facing Fixing Backing angle fixed with screws and coving clips into place Sealing Coving can be sealed at either edge with proprietary sealant. Job includes cost of material and labour charges |
| 6 | CEILING SUSPENDED AHU CUM LAMINAR DUCTLESS AIRFLOW SYSTEM (CEILING AHU) >= 8TR WITH AIR CHANGES PER HOUR (ACH) >=20Design, Supply, Installation, Testing & Commissioning of Ductless Air Handling Unit designed specifically for airborne infection control with airflow to be unidirectional and downwards on the OT table and air face velocity of 25-35 FPM (feet per minute) from non-aspirating unidirectional laminar flow diffuser/ceiling array. The unit shall be completely self-contained, ductless, and with outdoor unit capacity of >= 8 TR.The offered unit shall have integrated filtration, air sterilization, heating, cooling, and AI-based smart monitoring features to maintain controlled indoor air quality in compliance with WHO & CDC guidelines.Technical Specifications:AS PER SCOPE OF WORK AT SERIAL NO 6 |
| 7 | CLEAN-ROOM LUMINARIES WITH FRAME:LED peripheral lights of luminaries (working life rated >= 50,000 hours) for surface or recess mounting in operation should flush with the ceiling, with highly-specular metal frame. Luminaries cover made of highly-resistant, disinfectant-proof acrylic or plastic surface along with dimmable blast. It should have >= 5000 Lumens with IP66 (from room side) / IP65 rating or higher (from ceiling side), SS body and power factor of >= 0.9.Luminaries should have >=80 CRIwith Colour temperature of 4000 k to 6000 k and should be of reputed make like: Havells, Crompton, Phillips, Endura,Syska& Wipro.In false ceiling 2'X2'with light Intensity>=5000 Lumens. |
| 8 | SURGEON'S CONTROL PANELIt should have with minimum 20” LCD touch screen monitor. It should have all the controls within the theatre located on a touch screen control panel mounted in the theatre wall. The panel should incorporate all the necessary controls for the correct operation and monitoring of the equipment and services within the operating theatre The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. Control Panel will be user friendly & ease of operating & maintaining purpose. The panel should be “Membrane” type; configured to incorporate all the services that operation room staff require. The fascia should be made with superior quality UV resistance membrane with sterilization feature. The Panel should contain 9 service tiles as below: 1. Time Day Clock.2. Time Elapse Day Clock.3. General Lighting System. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller. 7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clock having high brightness characters. Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters, not less than30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. System inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. A hand free set Telephone System should be incorporated in the panel with memory type card. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification. |
| 9 | SS Pass Box: - SS 304 pass box having double door with interlock, Solid door with electrical interlocking, Window with tempered glass, UV-C (emits predominantly at 254 nm) lamp for sterilization.Storage Unit: - Providing and fixing Storage unit of size 1800 X 1200 X 250mm or as per instructions and direction of Medical Authorities and Engineer-in-charge having three shelves made of SS 304 grade, 5mm thick, Heat strengthens anti-microbial coating glass shutters.Writing Board: - flush mounted with sterile jointing systems, 1.50 MM thick white laminate board, bended to a 02 mm steel sheet for the additional rigidity.Modular stainless surgical scrub station or sink specially designed for the use in Operation Theatre. Stainless Steel 2 bay scrub sink made out of 304 graded brushed finished stainless steel, required length, with photo electric sensors,1 no. mixture valve 3 nos. solenoid valve. The unit shall have reduced ant splash front. Operation of the few sets should be through sensor and foot operation having user define setting in 1,3,5 and 10 minutes. • It should have thermostatic control with feel safe temperature control. • It should have front assess panel for maintenance and repairs. Job also includes dismantling of existing sanitary fittings and providing/laying of scrub station with latest facilities with all fittings, accessories and civil works. |
| 10 | PROVISION FOR AUDIO VIDEO CONFERENCING SYSTEMProvision for Audio Video conferencing system with 65” LED screens 2 nos. of 4k (UHD) quality of reputed make like Sony, Samsung and LG only one in the theatre and one outside in the hall for viewing of students, along with allied works for executing complete setup. The system should have mike and speakers open/concealed as per instructions of medical authority & Engineer-in-charge at both the ends with provision of one-way/two-way communication whenever required for fluent communication between doctors & students. DISTRIBUTION BOARD:Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house minimum ten MCB and mains failure relays, electrical distribution equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectors with screw and clamp spring connections of the Clip-on type mounted, on a DIN rail. Individual fuses or miniature circuit breakers should protect all internal circuits. It should have CE compliance under Class 1 Medical devices directive. All Electrical spare parts should be ISI certified only. INSIDE OT ELECTRICAL WIRING AND CONDUITS:Wiring with Low leakage current wires of FRLS wires as per individual operation theatre requirements including providing and fixing of conducting and boxes inside operation theatres. Wiring for 250 volts single phases and neutral 6/16. |
| 11 | SHADOWLESS SURGICAL OT LIGHT WITH SEPARATE CAMERA SYSTEMApplication: High-quality Surgical Operation Theatre (OT) Light with advanced illumination technology integrated with a separate full high-definition (HD) 4k camera system for surgical recording, teaching, telemedicine, and live streaming purposes.General Construction:Ceiling-mounted LED OT Light with separate Full HD 4k Camera System.• Modular design suitable for Major & Minor Surgical Procedures.• Separate Full HD4k Camera for clear visualization without disturbing the sterile field.Technical Specifications: OT Light Features:• Illumination Intensity: 1,60,000 Lux or more.• LED Life: Minimum 50,000 hours.• Colour Temperature: 3500K – 6000K (Adjustable).• Colour Rendering Index (CRI): ≥95 for accurate tissue colour differentiation.• Focus Diameter: Adjustable (as per surgical requirement).• Light Head Material: Medical-grade Aluminium Die Cast Body for better heat dissipation.• Shadow Reduction: Multi-reflector technology for clear visibility.• Memory Function for Intensity & Colour Settings.Separate Full HD 4k Camera Features:• Full HD Camera with 4K Resolution• Optical & Digital Zoom Functionality.• Manual / Auto Focus Control.• Ceiling Mounted — Separate Arm from Light Head.• 360° Rotation for flexible positioning.• Wireless Remote Control for Camera Operation.• Video Recording & Live Streaming Capabilities.• Output: HDMI / USB / LAN for connectivity.Control System:Touch Screen / Feather Touch Control Panel.• Intensity Adjustment.• Colour Temperature Control.• Camera Control Interface (Optional Remote).Additional Features:Sterilizable Handles on Light Head.• Battery Backup for Emergency Operation.• Anti-bacterial Powder Coating on all parts.• Suitable for Modular OT Design.• Smooth & Silent Movements of Light Arms.Compliance:Compliance with IEC / CE / ISO Standards.• Designed for Hospital Infection Control Protocols. |
| 12 | Twin Plate LED X-ray view panel:X-Ray view box is the necessary equipment in hospitals, medical institutes, and nursing homes. This single film X-ray view box is excellent in functioning and ensures optimal viewing quality due to the LED- based viewing. 1) Body: Powder coated MS cabinet with metal frame. 2)Sheet: Acrylicsheet.3) Power: 12v,50-60hz. 4)Bulb: High glossy LED bulbs. 5)Parts: Heavy duty switch and socket. 6) Safety: Shock proof mechanism. 7)Holding: Plastics clips for x-ray film holding. 8)Handling: Light weight & portable. 9) Dimmer: Dimmer to adjust the brightness of screen |
| 13 | PRESSURE RELEASE DAMPERAll operation rooms should be supplied/fitted with multi bladed damper specifically designed to control room air pressures. The pressure dampers will contain four grade 304 SS Blades which pivot upon sealed for life bearing assemblies. It should have CE compliance under Class I Medical devices directive. Damper Opening pressure range should be 15 to 65 pascals with adjustment via counter weight 30 to 300 pascal. |
| 14 | HERMATICALLY SEAL SINGLE LEAF SLIDING DOOR.Hermetically sealed clean room door in OT Doors shall be designed to fit flush into the wall panel systems. Automated with Manual override operated hermetically sealing sliding main door (as per instruction and direction of Medical Authorities and Engineer-in-charge) on OT of appropriate size. Having a track system wherein the door blade is guided under a 45-degree angle with approximately 6mm deep indentations at the closed position. • Having a special inside and outside lever handle that lifts out the door blade from its hermetically closing position thus allowing even very heavy doors to be opened effortlessly manually. • In case within an extruded anodised aluminium profile frame all around the door blade with solid high-pressure laminate on both sides. • Should have special nylon top roller with double roller bearing to enable the door to slide smoothly and silently • The door blade should have a special rubber/neoprine gasket, all around the door blade, for the hermetic sealing on the door and the wall frame. • The door blade is approximately 50 mm thick, made up of medium density fibre (MDF) core/PUF and having it on both its places hygienic hard plastic laminate which can withstand high abrasion • Vision panel- double glazed, laminated safety glass, flush finish on both side with door blade should be provided in the doors. • The automatic controller for the door should be microprocessor based with electromechanical sliding door drive. • The automation should be able to operate a door with maximum door weight of 250kg (approx.) door as per site requirement with width of 3500mm. • The automation should have variable/ adjustable opening and closing speed, with opening speed adjustable between 120 mm/sec-800mm/sec and closing speed adjustable between 120mm/sec-500mm/sec.• The automation/door can be controlled/operated using either push button switch, kick switch or sensor(touchless-infrared) switches or all in combine. • As a safety in the clear opening of the door. |
| 15 | OZONE GENERATOR (SOLUTION FOR FUMIGATION)1) Magical air disinfection without any chemicals. 2) Ozone generator kills all types of bacteria, fungus, virus, molds. Functions: 1) Formaldehyde treatment after house fitment peculiar smell removing, bleaching, decolorizing of restroom. 2) Peculiar smell elimination for cabinet, refrigerator, lampblack, rubbish. 3) Poisonous gas decomposing such as toluene, ethanol, carbon monoxide, sulphur dioxide. 4) Deodorization of chifforobe, shoes cabinet. 5) With ozone water have a bath to possess to bleach and the effect such as cosmetology and health protection. |
| 16 | DOUBLE ARMSURGEON PENDANTIt should be designed for safe and convenient management of medical gases, electrical supply, equipment load, and data communication.General Construction:• Double Arm Configuration for extended rotation and working radius.• Heavy-duty extruded aluminium arms with powder-coated finish for long-lasting durability and aesthetics.• 340° Rotating Arms with adjustable movement for flexibility and ease of positioning.• Modular Column System designed for optimum space utilization with load-bearing capacity.Technical Features:AS PER SCOPE OF WORK AT SERIAL NO 16 |
| 17 | DOUBLE ARM ANESTHESIA PENDANT Application:Designed for Modular Operation Theatres (MOT) & Intensive Care Units (ICU) for safe and convenient management of medical gases, electrical supply, equipment load, and data communication.AS PER SCOPE OF WORK AT SERIAL NO 17 |
| 18 | THEATRE SUCTION TROLLEYS: It should fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 10079-3: 2009 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices. It should be light weight and Polysulphone collection Jar of 2 litres with lid: it should be unbreakable and autoclavable up to 134 °C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility.High Suction Theatre Vacuum Unit: It should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from - 45degree to +45degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of the pre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment:2.5turns are enough to reach the maximum vacuum level. It should have vacuum levels: 0-1000 mbar/hPa. The vacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134 ° C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. It should be light weight 490g and dimensions (height230mm X Width 70mm X Depth 90mm). Polysulphone collection Jar of 2litres with lid: it should be unbreakable and autoclavable up to 134° C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. It should fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 10079-3: 2009 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices.Low Suction Theatre Vacuum Unit: It should fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 10079-3: 2009 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices: Low Vacuum Regulator: It should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from -45degree to +45degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of the pre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment :2.5turns are enough to reach the maximum vacuum level. It should have vacuum levels: 0- 250 mbar/hPa. The vacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134 ° C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. It should be light weight 490g and dimensions (height230mm X Width 70mm X Depth 90mm). Polysulphone collection Jar of 1litres with lid: it should be unbreakable and autoclavable up to 134° C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. |
| 19 | B)Ductless Modular OT no. 2 of size 20’ X 20’ X 11’in Paediatrics Surgery OT Complex along with allied works at Govt SMGS Hospital, Jammu.PPGI WALL PANELProviding and Fixing/Installation Pre-fabricated PPGI on both sides Puff panel with 50mm thickness wall panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside to became soundproof & with anti-bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler. Job also involves painting of at least 2 coats of antibacterial paint on all the walls of OT. Job also includes supply and fixing of the accessories for the panels like L angle, c flashing, screw, t-section support etc. Job includes cost of material and labour charges. |
| 20 | PPGI FALSE CEILINGProviding and Fixing/Installation Pre-fabricated PPGI on both sides Puff panel with 50mm thickness false ceiling panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside to became soundproof & with anti-bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler. Job also involves painting of at least 2 coats of antibacterial paint on all the walls of OT. Job also includes supply and fixing of the accessories for the panels like L angle, c flashing, screw, t-section support etc. Job includes cost of material and labour charges. |
| 21 | ANTI-STATIC VINYL FLOORING. Providing & fixing 3 mm thick Vinyl flooring with carbon granules colour, scratch resistant, fire resistant, chemical resistant, slip resistant, anti-fungi & bacterial growth, electrical resistant. Installation: The flooring would be installed on a smooth, clean sub floor which should be free from any undulation. Resistant to Mechanical stress and dynamic loads. It should be washable. Job includes cost of material and labour charges. |
| 22 | ALUMINIUM COVING Aluminium coving with PVC coating and Dimensions of minimum 50mm radius and length as per site requirement. Aluminium 6063 backing angle fixed with screws and coving clips into place Sealing Coving at either edge with proprietary sealant. Job includes cost of material and labour charges. |
| 23 | VINYL COVINGVinyl coving with Dimensions of minimum 50 mm radius and length as per site requirement. Material Aluminium 6063 backing angle facing Fixing Backing angle fixed with screws and coving clips into place Sealing Coving can be sealed at either edge with proprietary sealant. Job includes cost of material and labour charges |
| 24 | CEILING SUSPENDED AHU CUM LAMINAR DUCTLESS AIRFLOW SYSTEM (CEILING AHU) >= 8TR WITH AIR CHANGES PER HOUR (ACH) >=20Design, Supply, Installation, Testing & Commissioning of Ductless Air Handling Unit designed specifically for airborne infection control with airflow to be unidirectional and downwards on the OT table and air face velocity of 25-35 FPM (feet per minute) from non-aspirating unidirectional laminar flow diffuser/ceiling array. The unit shall be completely self-contained, ductless, and with outdoor unit capacity of >= 8 TR.The offered unit shall have integrated filtration, air sterilization, heating, cooling, and AI-based smart monitoring features to maintain controlled indoor air quality in compliance with WHO & CDC guidelines.AS PER SCOPE OF WORK AT SERIAL NO.24 |
| 25 | CLEAN-ROOM LUMINARIES WITH FRAME:LED peripheral lights of luminaries (working life rated >= 50,000 hours) for surface or recess mounting in operation should flush with the ceiling, with highly-specular metal frame. Luminaries cover made of highly-resistant, disinfectant-proof acrylic or plastic surface along with dimmable blast. It should have >= 5000 Lumens with IP66 (from room side) / IP65 rating or higher (from ceiling side), SS body and power factor of >= 0.9. Luminaries should have >= 80 CRI with Colour temperature of 4000 k to 6000 k and should be of reputed make like: Havells, Crompton, Phillips, Endura, Syska & Wipro.In false ceiling 2'X2'with light Intensity >= 5000 Lumens. |
| 26 | SURGEON'S CONTROL PANELIt should have with minimum 20” LCD touch screen monitor. It should have all the controls within the theatre located on a touch screen control panel mounted in the theatre wall. The panel should incorporate all the necessary controls for the correct operation and monitoring of the equipment and services within the operating theatre The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. Control Panel will be user friendly & ease of operating & maintaining purpose. The panel should be “Membrane” type; configured to incorporate all the services that operation room staff require. The fascia should be made with superior quality UV resistance membrane with sterilization feature. The Panel should contain 9 service tiles as below: 1. Time Day Clock.2. Time Elapse Day Clock.3. General Lighting System. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller. 7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clock having high brightness characters. Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. System inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. A hand free set Telephone System should be incorporated in the panel with memory type card. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification. |
| 27 | SS Pass Box: - SS 304 pass box having double door with interlock, Solid door with electrical interlocking, Window with tempered glass, UV-C (emits predominantly at 254 nm) lamp for sterilization.Storage Unit: - Providing and fixing Storage unit of size 1800 X 1200 X 250mm or as per instructions and direction of Medical Authorities and Engineer-in-charge having three shelves made of SS 304 grade, 5mm thick, Heat strengthens anti-microbial coating glass shutters.Writing Board: - flush mounted with sterile jointing systems, 1.50 MM thick white laminate board, bended to a 02 mm steel sheet for the additional rigidity.Modular stainless surgical scrub station or sink specially designed for the use in Operation Theatre. Stainless Steel 2 bay scrub sink made out of 304 graded brushed finished stainless steel, required length, with photo electric sensors,1 no. mixture valve 3 nos. solenoid valve. The unit shall have reduced ant splash front. Operation of the few sets should be through sensor and foot operation having user define setting in 1,3,5 and 10 minutes. • It should have thermostatic control with feel safe temperature control. • It should have front assess panel for maintenance and repairs. Job also includes dismantling of existing sanitary fittings and providing/laying of scrub station with latest facilities with all fittings, accessories and civil works |
| 28 | PROVISION FOR AUDIO VIDEO CONFERENCING SYSTEMProvision for Audio Video conferencing system with 65” LED screens 2 nos. of 4k (UHD) quality of reputed make like Sony, Samsung and LG only one in the theatre and one outside in the hall for viewing of students, along with allied works for executing complete setup. The system should have mike and speakers open/concealed as per instructions of medical authority & Engineer-in-charge at both the ends with provision of one-way/two-way communication whenever required for fluent communication between doctors & students. DISTRIBUTION BOARD:Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house minimum ten MCB and mains failure relays, electrical distribution equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectors with screw and clamp spring connections of the Clip-on type mounted, on a DIN rail. Individual fuses or miniature circuit breakers should protect all internal circuits. It should have CE compliance under Class 1 Medical devices directive. All Electrical spare parts should be ISI certified only. INSIDE OT ELECTRICAL WIRING AND CONDUITS:Wiring with Low leakage current wires of FRLS wires as per individual operation theatre requirements including providing and fixing of conducting and boxes inside operation theatres. Wiring for 250 volts single phases and neutral 6/16. |
| 29 | SHADOWLESS SURGICAL OT LIGHT WITH SEPARATE CAMERA SYSTEMApplication: High-quality Surgical Operation Theatre (OT) Light with advanced illumination technology integrated with a separate full high-definition (HD) 4k camera system for surgical recording, teaching, telemedicine, and live streaming purposes.General Construction:• Ceiling-mounted LED OT Light with separate Full HD 4k Camera System.• Modular design suitable for Major & Minor Surgical Procedures.• Separate Full HD 4k Camera for clear visualization without disturbing the sterile field.Technical Specifications: OT Light Features:• Illumination Intensity: 1,60,000 Lux or more.• LED Life: Minimum 50,000 hours.• Colour Temperature: 3500K – 6000K (Adjustable).• Colour Rendering Index (CRI): ≥95 for accurate tissue colour differentiation.• Focus Diameter: Adjustable (as per surgical requirement).• Light Head Material: Medical-grade Aluminium Die Cast Body for better heat dissipation.• Shadow Reduction: Multi-reflector technology for clear visibility.• Memory Function for Intensity & Colour Settings. Separate Full HD 4k Camera Feat0-.• • Full HD Camera with 4K Resolution• Optical & Digital Zoom Functionality• Manual/Auto Focus ControlCeiling Mounted — Separate Arm from Light Head.• 360° Rotation for flexible positioning.• Wireless Remote Control for Camera Operation.• Video Recording & Live Streaming Capabilities.• Output: HDMI / USB / LAN for connectivity. Control System:• Touch Screen / Feather Touch Control Panel.• Intensity Adjustment.• Colour Temperature Control.• Camera Control Interface (Optional Remote). Additional Features:• Sterilizable Handles on Light Head.• Battery Backup for Emergency Operation.• Anti-bacterial Powder Coating on all parts.• Suitable for Modular OT Design.• Smooth & Silent Movements of Light Arms. Compliance:• Compliance with IEC / CE / ISO Standards.• Designed for Hospital Infection Control Protocols. |
| 30 | Twin Plate LED X-ray view panel:X-Ray view box is the necessary equipment in hospitals, medical institutes, and nursing homes. This single film X-ray view box is excellent in functioning and ensures optimal viewing quality due to the LED- based viewing. 1) Body: Powder coated MS cabinet with metal frame. 2)Sheet: Acrylicsheet.3) Power: 12v,50-60hz. 4)Bulb: High glossy LED bulbs. 5)Parts: Heavy duty switch and socket. 6) Safety: Shock proof mechanism. 7)Holding: Plastics clips for x-ray film holding. 8)Handling: Light weight & portable. 9) Dimmer: Dimmer to adjust the brightness of screen. |
| 31 | PRESSURE RELEASE DAMPERAll operation rooms should be supplied/fitted with multi bladed damper specifically designed to control room air pressures. The pressure dampers will contain four grade 304 SS Blades which pivot upon sealed for life bearing assemblies. It should have CE compliance under Class I Medical devices directive. Damper Opening pressure range should be 15 to 65 pascals with adjustment via counter weight 30 to 300 pascal. |
| 32 | HERMATICALLY SEAL SINGLE LEAF SLIDING DOOR.Hermetically sealed clean room door in OT Doors shall be designed to fit flush into the wall panel systems. Automated with Manual override operated hermetically sealing sliding main door (as per instruction and direction of Medical Authorities and Engineer-in-charge) on OT of appropriate size. Having a track system wherein the door blade is guided under a 45-degree angle with approximately 6mm deep indentations at the closed position. • Having a special inside and outside lever handle that lifts out the door blade from its hermetically closing position thus allowing even very heavy doors to be opened effortlessly manually. • In case within an extruded anodised aluminium profile frame all around the door blade with solid high-pressure laminate on both sides. • Should have special nylon top roller with double roller bearing to enable the door to slide smoothly and silently • The door blade should have a special rubber/neoprine gasket, all around the door blade, for the hermetic sealing on the door and the wall frame. • The door blade is approximately 50 mm thick, made up of medium density fibre (MDF) core/PUF and having it on both its places hygienic hard plastic laminate which can withstand high abrasion • Vision panel- double glazed, laminated safety glass, flush finish on both side with door blade should be provided in the doors. • The automatic controller for the door should be microprocessor based with electromechanical sliding door drive. • The automation should be able to operate a door with maximum door weight of 250kg (approx.) door as per site requirement with width of 3500mm. • The automation should have variable/ adjustable opening and closing speed, with opening speed adjustable between 120 mm/sec-800mm/sec and closing speed adjustable between 120mm/sec-500mm/sec.• The automation/door can be controlled/operated using either push button switch, kick switch or sensor(touchless-infrared) switches or all in combine. • As a safety in the clear opening of the door. |
| 33 | OZONE GENERATOR (SOLUTION FOR FUMIGATION)1) Magical air disinfection without any chemicals. 2) Ozone generator kills all types of bacteria, fungus, virus, molds. Functions: 1) Formaldehyde treatment after house fitment peculiar smell removing, bleaching, decolorizing of restroom. 2) Peculiar smell elimination for cabinet, refrigerator, lampblack, rubbish. 3) Poisonous gas decomposing such as toluene, ethanol, carbon monoxide, sulphur dioxide. 4) Deodorization of chifforobe, shoes cabinet. 5) With ozone water have a bath to possess to bleach and the effect such as cosmetology and health protection |
| 34 | DOUBLE ARMSURGEON PENDANTIt should be designed for safe and convenient management of medical gases, electrical supply, equipment load, and data communication.General Construction:• Double Arm Configuration for extended rotation and working radius.• Heavy-duty extruded aluminium arms with powder-coated finish for long-lasting durability and aesthetics.• 340° Rotating Arms with adjustable movement for flexibility and ease of positioning.• Modular Column System designed for optimum space utilization with load-bearing capacity.AS PER SCOPE OF WORK AT SERIAL NO 34 |
| 35 | DOUBLE ARM ANESTHESIA PENDANT Application:Designed for Modular Operation Theatres (MOT) & Intensive Care Units (ICU) for safe and convenient management of medical gases, electrical supply, equipment load, and data communication.AS PER SCOPE OF WORK AT SERIAL NO 35 |
| 36 | THEATRE SUCTION TROLLEYS: It should fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 10079-3: 2009 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices. It should be light weight and Polysulphone collection Jar of 2 litres with lid: it should be unbreakable and autoclavable up to 134 °C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility.High Suction Theatre Vacuum Unit: It should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from - 45degree to +45degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of the pre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment:2.5turns are enough to reach the maximum vacuum level. It should have vacuum levels: 0-1000 mbar/hPa. The vacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134 ° C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. It should be light weight 490g and dimensions (height230mm X Width 70mm X Depth 90mm). Polysulphone collection Jar of 2litres with lid: it should be unbreakable and autoclavable up to 134° C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. It should fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 10079-3: 2009 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices.Low Suction Theatre Vacuum Unit: It should fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 10079-3: 2009 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices: Low Vacuum Regulator: It should be continuous vacuum regulator, compact, strong and ergonomic device. It should have manual adjustment of the vacuum gauge from -45 degree to +45 degree for a better visibility. Vacuum gauge should be protected by a plastic housing. It should have on/off switch-button providing a quick restoration of the pre-adjusted vacuum level. It should have central regulation knob with a free rotation at the end of the course (impossible blocking). It should have quick adjustment :2.5turns are enough to reach the maximum vacuum level. It should have vacuum levels: 0- 250 mbar/hPa. The vacuum regulator should be 3-in-1 system. It should have a device with a metal outlet tubing nipple integrated in the body of the regulator for a better safety, emergency suctions can even be processed. It should be supplied with a 100ml safety jar equipped with a mechanical anti-over flow safety valve and single use antibacterial plastic filter upfront. The safety jar should be made of polycarbonate, autoclavable up to 134 ° C and unbreakable. The safety jar should be fixed by an easy-click rotation. The safety jar should be able to rotate to avoid any pinch of the tubing. It should have a unit serial number laser engraved on the body of each vacuum regulator ensuring its identifications and traceability. It should be light weight 490g and dimensions (height 230mm X Width 70mm X Depth 90mm). Polysulphone collection Jar of 1litres with lid: it should be unbreakable and autoclavable up to 134° C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility. |
| 37 | C)Ductless Modular OT no. 3 of size 20’ X 20’ X 11’in Paediatrics Surgery OT Complex along with allied works at Govt SMGS Hospital, JammuPPGI WALL PANELProviding and Fixing/Installation Pre-fabricated PPGI on both sides Puff panel with 50mm thickness wall panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside to became soundproof & with anti-bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler. Job also involves painting of at least 2 coats of antibacterial paint on all the walls of OT. Job also includes supply and fixing of the accessories for the panels like L angle, c flashing, screw, t-section support etc. Job includes cost of material and labour charges. |
| 38 | PPGI FALSE CEILINGProviding and Fixing/Installation Pre-fabricated PPGI on both sides Puff panel with 50mm thickness false ceiling panels. PPGI Sheet of 0.8mm thick Panel filled with hard puff inside to became soundproof & with anti-bacterial & antifungal properties Low heat transmission with GI profile for joining two panels with filling of all joints and cavities with medical grade silicon epoxy filler. Job also involves painting of at least 2 coats of antibacterial paint on all the walls of OT. Job also includes supply and fixing of the accessories for the panels like L angle, c flashing, screw, t-section support etc. Job includes cost of material and labour charges. |
| 39 | ANTI-STATIC VINYL FLOORING. Providing & fixing 3 mm thick Vinyl flooring with carbon granules colour, scratch resistant, fire resistant, chemical resistant, slip resistant, anti-fungi & bacterial growth, electrical resistant. Installation: The flooring would be installed on a smooth, clean sub floor which should be free from any undulation. Resistant to Mechanical stress and dynamic loads. It should be washable. Job includes cost of material and labour charges |
| 40 | ALUMINIUM COVING Aluminium coving with PVC coating and Dimensions of minimum 50mm radius and length as per site requirement. Aluminium 6063 backing angle fixed with screws and coving clips into place Sealing Coving at either edge with proprietary sealant. Job includes cost of material and labour charges. |
| 41 | VINYL COVINGVinyl coving with Dimensions of minimum 50 mm radius and length as per site requirement. Material Aluminium 6063 backing angle facing Fixing Backing angle fixed with screws and coving clips into place Sealing Coving can be sealed at either edge with proprietary sealant. Job includes cost of material and labour charges |
| 42 | CEILING SUSPENDED AHU CUM LAMINAR DUCTLESS AIRFLOW SYSTEM (CEILING AHU) >= 8TR WITH AIR CHANGES PER HOUR (ACH) >=20Design, Supply, Installation, Testing & Commissioning of Ductless Air Handling Unit designed specifically for airborne infection control with airflow to be unidirectional and downwards on the OT table and air face velocity of 25-35 FPM (feet per minute) from non-aspirating unidirectional laminar flow diffuser/ceiling array. The unit shall be completely self-contained, ductless, and with outdoor unit capacity of >= 8 TR.The offered unit shall have integrated filtration, air sterilization, heating, cooling, and AI-based smart monitoring features to maintain controlled indoor air quality in compliance with WHO & CDC guidelines.AS PER SCOPE OF WORK AT SERIAL NO 42 |
| 43 | CLEAN-ROOM LUMINARIES WITH FRAME:LED peripheral lights of luminaries (working life rated >= 50,000 hours) for surface or recess mounting in operation should flush with the ceiling, with highly-specular metal frame. Luminaries cover made of highly-resistant, disinfectant-proof acrylic or plastic surface along with dimmable blast. It should have >= 5000 Lumens with IP66 (from room side) / IP65 rating or higher (from ceiling side), SS body and power factor of >= 0.9. Luminaries should have >= 80 CRI with Colour temperature of 4000 k to 6000 k and should be of reputed make like: Havells, Crompton, Phillips, Endura, Syska & Wipro.In false ceiling 2'X2'with light Intensity >= 5000 Lumens. |
| 44 | SURGEON'S CONTROL PANELIt should have with minimum 20” LCD touch screen monitor. It should have all the controls within the theatre located on a touch screen control panel mounted in the theatre wall. The panel should incorporate all the necessary controls for the correct operation and monitoring of the equipment and services within the operating theatre The surgeon control panel should meet Electrical safety codes for high & low voltage system, wired to the current IEE regulations. Control Panel will be user friendly & ease of operating & maintaining purpose. The panel should be “Membrane” type; configured to incorporate all the services that operation room staff require. The fascia should be made with superior quality UV resistance membrane with sterilization feature. The Panel should contain 9 service tiles as below: 1. Time Day Clock.2. Time Elapse Day Clock.3. General Lighting System. 4. Medical Gas Alarm Panel. 5. Hand Free Telephone set with memory.6. Temperature & humidity indicator with controller. 7. HEPA Filter Status module. 8. Room Pressure Indicator. 9. Music control. Time day clock should be digital type & clocks having high brightness characters. Time Elapsed Day Clock should be digital type & clock having high brightness characters. Temperature indicator should indicate the room temperature which should be connected to the local pressure switches of Air-Conditioning System. Indicators should be digital type & clocks having high brightness characters, not less than 30 mm in height. Central Lighting system should incorporate all the necessary controls of the lighting. System inside the theatre. The medical gas alarm should indicate High, Normal & Low gas Pressure for each gas service present in the operating system & should have an audible buzzer with mute facility. Pressure sensors should be connected to MGPS for monitoring the pressures. A hand free set Telephone System should be incorporated in the panel with memory type card. The control panel should be designed for front- access only. All internal wires should be marked with plastic Ferrule type cable markers for ease of identification. |
| 45 | SS Pass Box: - SS 304 pass box having double door with interlock, Solid door with electrical interlocking, Window with tempered glass, UV-C (emits predominantly at 254 nm) lamp for sterilization.Storage Unit: - Providing and fixing Storage unit of size 1800 X 1200 X 250mm or as per instructions and direction of Medical Authorities and Engineer-in-charge having three shelves made of SS 304 grade, 5mm thick, Heat strengthens anti-microbial coating glass shutters.Writing Board: - flush mounted with sterile jointing systems, 1.50 MM thick white laminate board, bended to a 02 mm steel sheet for the additional rigidity.Modular stainless surgical scrub station or sink specially designed for the use in Operation Theatre. Stainless Steel 2 bay scrub sink made out of 304 graded brushed finished stainless steel, required length, with photo electric sensors,1 no. mixture valve 3 nos. solenoid valve. The unit shall have reduced ant splash front. Operation of the few sets should be through sensor and foot operation having user define setting in 1,3,5 and 10 minutes. • It should have thermostatic control with feel safe temperature control. • It should have front assess panel for maintenance and repairs. Job also includes dismantling of existing sanitary fittings and providing/laying of scrub station with latest facilities with all fittings, accessories and civil works. |
| 46 | PROVISION FOR AUDIO VIDEO CONFERENCING SYSTEMProvision for Audio Video conferencing system with 65” LED screens 2 nos. of 4k (UHD) quality of reputed make like Sony, Samsung and LG only one in the theatre and one outside in the hall for viewing of students, along with allied works for executing complete setup. The system should have mike and speakers open/concealed as per instructions of medical authority & Engineer-in-charge at both the ends with provision of one-way/two-way communication whenever required for fluent communication between doctors & students. DISTRIBUTION BOARD:Electrical Distribution Board will have all high voltage equipment should be installed in a separate enclosure. The remote cabinet should house minimum ten MCB and mains failure relays, electrical distribution equipment and circuit protection equipment for all circuits within the operating theatre. All internal wiring should terminate in connectors with screw and clamp spring connections of the Clip-on type mounted, on a DIN rail. Individual fuses or miniature circuit breakers should protect all internal circuits. It should have CE compliance under Class 1 Medical devices directive. All Electrical spare parts should be ISI certified only. INSIDE OT ELECTRICAL WIRING AND CONDUITS:Wiring with Low leakage current wires of FRLS wires as per individual operation theatre requirements including providing and fixing of conducting and boxes inside operation theatres. Wiring for 250 volts single phases and neutral 6/16. |
| 47 | SHADOWLESS SURGICAL OT LIGHT WITH SEPARATE CAMERA SYSTEMApplication: High-quality Surgical Operation Theatre (OT) Light with advanced illumination technology integrated with a separate full high-definition (HD) 4k camera system for surgical recording, teaching, telemedicine, and live streaming purposes.General Construction:• Ceiling-mounted LED OT Light with separate Full HD 4k Camera System.• Modular design suitable for Major & Minor Surgical Procedures.• Separate Full HD 4k Camera for clear visualization without disturbing the sterile field.AS PER SCOPE OF WORK AT SERIAL NO 47 |
| 48 | Twin Plate LED X-ray view panel:X-Ray view box is the necessary equipment in hospitals, medical institutes, and nursing homes. This single film X-ray view box is excellent in functioning and ensures optimal viewing quality due to the LED- based viewing. 1) Body: Powder coated MS cabinet with metal frame. 2)Sheet: Acrylicsheet.3) Power: 12v,50-60hz. 4)Bulb: High glossy LED bulbs. 5)Parts: Heavy duty switch and socket. 6) Safety: Shock proof mechanism. 7)Holding: Plastics clips for x-ray film holding. 8)Handling: Light weight & portable. 9) Dimmer: Dimmer to adjust the brightness of screen. |
| 49 | PRESSURE RELEASE DAMPERAll operation rooms should be supplied/fitted with multi bladed damper specifically designed to control room air pressures. The pressure dampers will contain four grade 304 SS Blades which pivot upon sealed for life bearing assemblies. It should have CE compliance under Class I Medical devices directive. Damper Opening pressure range should be 15 to 65 pascals with adjustment via counter weight 30 to 300 pascal. |
| 50 | HERMATICALLY SEAL SINGLE LEAF SLIDING DOOR.Hermetically sealed clean room door in OT Doors shall be designed to fit flush into the wall panel systems. Automated with Manual override operated hermetically sealing sliding main door (as per instruction and direction of Medical Authorities and Engineer-in-charge) on OT of appropriate size. Having a track system wherein the door blade is guided under a 45-degree angle with approximately 6mm deep indentations at the closed position. • Having a special inside and outside lever handle that lifts out the door blade from its hermetically closing position thus allowing even very heavy doors to be opened effortlessly manually. • In case within an extruded anodised aluminium profile frame all around the door blade with solid high-pressure laminate on both sides. • Should have special nylon top roller with double roller bearing to enable the door to slide smoothly and silently • The door blade should have a special rubber/neoprine gasket, all around the door blade, for the hermetic sealing on the door and the wall frame. • The door blade is approximately 50 mm thick, made up of medium density fibre (MDF) core/PUF and having it on both its places hygienic hard plastic laminate which can withstand high abrasion • Vision panel- double glazed, laminated safety glass, flush finish on both side with door blade should be provided in the doors. • The automatic controller for the door should be microprocessor based with electromechanical sliding door drive. • The automation should be able to operate a door with maximum door weight of 250kg (approx.) door as per site requirement with width of 3500mm. • The automation should have variable/ adjustable opening and closing speed, with opening speed adjustable between 120 mm/sec-800mm/sec and closing speed adjustable between 120mm/sec-500mm/sec.• The automation/door can be controlled/operated using either push button switch, kick switch or sensor(touchless-infrared) switches or all in combine. • As a safety in the clear opening of the door |
| 51 | OZONE GENERATOR (SOLUTION FOR FUMIGATION)1) Magical air disinfection without any chemicals. 2) Ozone generator kills all types of bacteria, fungus, virus, molds. Functions: 1) Formaldehyde treatment after house fitment peculiar smell removing, bleaching, decolorizing of restroom. 2) Peculiar smell elimination for cabinet, refrigerator, lampblack, rubbish. 3) Poisonous gas decomposing such as toluene, ethanol, carbon monoxide, sulphur dioxide. 4) Deodorization of chifforobe, shoes cabinet. 5) With ozone water have a bath to possess to bleach and the effect such as cosmetology and health protection. |
| 52 | DOUBLE ARMSURGEON PENDANTIt should be designed for safe and convenient management of medical gases, electrical supply, equipment load, and data communication.General Construction:• Double Arm Configuration for extended rotation and working radius.• Heavy-duty extruded aluminium arms with powder-coated finish for long-lasting durability and aesthetics.• 340° Rotating Arms with adjustable movement for flexibility and ease of positioning.• Modular Column System designed for optimum space utilization with load-bearing capacity.AS PER SCOPE OF WORK AT SERIAL NO 52 |
| 53 | DOUBLE ARM ANESTHESIA PENDANT Application:Designed for Modular Operation Theatres (MOT) & Intensive Care Units (ICU) for safe and convenient management of medical gases, electrical supply, equipment load, and data communication.AS PER SCOPE OF WORK AT SERIAL NO 53 |
| 54 | THEATRE SUCTION TROLLEYS: It should fully comply and meets with active medical device of class IIa and in compliance with the EN ISO 10079-3: 2009 standard. It should be duly CE marked and comply with 93/42/EEC Medical Devices. It should be light weight and Polysulphone collection Jar of 2 litres with lid: it should be unbreakable and autoclavable up to 134 °C must be fitted with an extremely simple anti overflow safety device, thereby ensuring easy maintenance. Should be totally transparent, they ensure perfect sucked liquid visibility.AS PER SCOPE OF WORK AT SERIAL NO 54 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 12, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 26, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender