Tender For Repair To Internal Wiring Including Fittings/Fixtures To Various Otms Under Ge Missamari
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Sep 2026
12 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sonitpur → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair To Internal Wiring Including Fittings/Fixtures To Various Otms Under Ge Missamari
BOQ
| Sl. No. | Item Description |
| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. seperating serviceable fittings/fixtures, keeping in safe custody reuse under respective item and removal of unserviceable material from site and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.Note:- Concealed conduit in RCC slab/beam shall not be not be taken out |
| 2 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description including making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 3 | Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as directed. |
| 4 | M&L concealed point wiring for One light point/Ceiling fan/Exhaut fan/bell point controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators/sockets] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. |
| 5 | All as per item No 4 here-in-above but One socket out let 5/6 amps point on the same board |
| 6 | All as per item No 4 here-in-above but One socket out let 5/6 amps point on the independent board |
| 7 | All as per item No 4 here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps. |
| 8 | M&L concealed point wiring for One one socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators/socket] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. (ii) Where concealing of conduit is not feasible i.e. on surface of RCC roof slab, beam etc, conduit shall be fixed on surface with necessary saddles at no extra cost. |
| 9 | M&L surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 10 | All as per item No 9 here-in-above but One socket out let 5/6 amps point on the same board. |
| 11 | All as per item No 9 here-in-above but One socket out let 5/6 amps point on the independent board. |
| 12 | All as per item No 9 here-in-above but One Light point controlled by two numbers two way switches 5/6 Amps. |
| 13 | M&L surface point wiring for One socket outlet 15 Amps point on independent board point controlled by one way switch 15/16 amps complete with 2.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LSH cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LSH (ISI marked) as earth continuity conductor connected to common earth dolly, flush GI modular suken terminal box [0,7mm thick (minimum) clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type socket/regulators] concealed in walls, with with back plate and cover plate of appropriate size & thickness for mounting switch, sockets etc with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 14 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 15 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 16 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 17 | M&L Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 18 | S&F in replacement Switch piano(white), flush type single pole, one way 5/6 Amp complete all as specified and as directed. |
| 19 | Fixing only Switch piano,flush type single pole, one way 5/6 Amp complete all as specified and as directed.Note:- Serviceable Piano Switch obtained from Item No 1 here-in-before |
| 20 | S&F in replacement Switch piano, flush type (white) single pole, two way 5/6 Amp complete all as specified and as directed. |
| 21 | S&F Bell push, flush type (white), 5/6 amps, flush type complete all as specified and as directed. |
| 22 | S&F in replacement Socket (white) outlet 2 in 1, 3/5 pin, 5/6 Amps flush type complete all as specified and as directed. |
| 23 | Fixing only Socket flush type multipurpose 2/3 pin 5/6 Amp complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 1 here-in-before |
| 24 | S&F in replacement Switch socket combination (white) 2 in 1, 3/5 pin, 5/6 Amp flush type universal complete all as specified and as directed. |
| 25 | Fixing only Switch socket combination flush type 2 in 1, 3/5 pin, 5 Amp complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 1 here-in-before |
| 26 | S&F in replacement Switch socket combination 2 in 1, 3/5 pin, 15/16 Amp flush type universal complete all as specified and as directed. |
| 27 | S&F in replacement switch (white), flush type, single pole, one way, 15/16 Amps complete all as specified and as directed |
| 28 | S&F in replacement Socket (white), flush type, single pole, one way, 15/16 Amps complete all as specified and as directed. |
| 29 | Fixing only Switch socket combination 2 in 1, 3 pin, 15/16 Amp complete all as specified and as directed.Note:- Serviceable Socket obtained from Item No 1 here-in-before |
| 30 | S&F ceilling rose(white) three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm complete all specified |
| 31 | Fixing only ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volt of size 65x50mm complete all specifiedNote:- Serviceable Socket obtained from Item No 1 here-in-before |
| 32 | S & F ceiling fan regulator (white) step type, heavy duty suitable to work on 230 Volt AC supply complete all as specified. |
| 33 | Fixing only fan regulator step type, heavy duty suitable to work on 230 Volt AC supply complete all as specified.Note:- Serviceable regulators obtained from Item No 1 here-in-before |
| 34 | S&F lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/angle fittings complete all as specified and directed. |
| 35 | Fixing only lamp holder, insulated PVC/ Polycarbonate body, with back plate suitable for batten/angle fittings complete all as specified and directed.Note:- Serviceable lamp holder, obtained from Item No 1 here-in-before |
| 36 | S&F in replacement call Bell, AC, 230 volts, single pole complete all as specified and as directed. |
| 37 | S&F LED bulb 10 watt 5 STAR LAMP with B 22 base capacity 1200 lumen 6500K complete all as specified. |
| 38 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed |
| 39 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Single pole & neutral with 200 Amps rated bus bar,240 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed |
| 40 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), IP-43 double door, Triple pole & neutral with 200 Amps rated bus bar,415 Volts, IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directed |
| 41 | S&F in replacement MCB, TPN, C Series 415 Volts, 63 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 42 | S & F in replacement MCB SPN 230 volts suitable for fixing on MCB DB of capacity 40 Amps complete all as specified. |
| 43 | S&F in replacement MCB, SP, C Series 240 Volts, 6-32 Amps 50 HZ, 10KA complete all as specified and as directed. |
| 44 | Supply and sixing LED lights fitting 1x20W, 6500K, 220V, AC decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, enviromenttal friendly energy efficient ready to use pack with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 45 | S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and PC Cover having TOP opening separate driver compartment with IP 66 Protection and imapct resistance of IK07 with electronic driver of capacity 20 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade of aququate dia 1.2 mtr long bend to required shape complete all as specified and as directed. |
| 46 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted 2 feet LED batton with polycarbonate housing & integrated electronic driver, with high efficient LEDs 9 watt, (or next nearer higher watt) with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed. |
| 47 | S&F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. |
| 48 | S&F LED bulb 10 watt 5 STAR LAMP with B 22 base capacity 1200 lumen 6500K complete all as specified. |
| 49 | S&F ceiling fan capacitor 2.25 mfd as per site requirement heavy duty with metal body including removal of old existing unserviceable one complete all as specified and directed. |
| 50 | S&F ceiling fan capacitor 2.5 mfd as per site requirement heavy duty with metal body including removal of old existing unserviceable one complete all as specified and directed. |
| 51 | S&F ceiling fan capacitor 3.15 mfd as per site requirement heavy duty with metal body including removal of old existing unserviceable one complete all as specified and directed. |
| 52 | S&F ceiling fan capacitor 4 mfd as per site requirement heavy duty with metal body including removal of old existing unserviceable one complete all as specified and directed. |
| 53 | S&F ceiling fan capacitor 6 mfd as per site requirement heavy duty with metal body including removal of old existing unserviceable one complete all as specified and directed. |
| 54 | Taking up the existing unservicable UG cable of any type/ description as existing at site complete all as directedNote : Earthwork will be measured and paid seperately. |
| 55 | Relaying Serviceable LT UG XLPE cable of size 3.5 core x 35/50 sq mm obtained from item no. 54 laid in trenches/ floors/ on wall/ service connections after cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCB with necessary lugs after cutting to required length of cable all as specified and directed. Note:- Serviceable Cable obtained from Item No 54 here-in-before |
| 56 | Relaying Serviceable LT UG XLPE cable of size 3.5 core x 16/25 sq mm obtained from item no. 54 laid in trenches/ floors/ on wall/ service connections after cutting and jointing through Cable Joint kit as per site requirement including connecting to the main switches/ cut outs MCB/ MCCB with necessary lugs after cutting to required length of cable all as specified and directed. Note:- Serviceable Cable obtained from Item No 54 here-in-before |
| 57 | Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 58 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 3.5 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 59 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core laid in trenches/ floors/ on wall/ run through pipe/pole and connecting to the main switches/ cut outs MCB/ MCCB/Pole with necessary lugs complete all as specified and as directed. |
| 60 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of cables etc and getting out in soft/loose soil including taking out of LT UG cable complete all as specified and as directed. |
| 61 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed. |
| 62 | Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed. |
| 63 | Supply and laying well burnt Bricks, locally available best quality (sub class \\"B\\" bricks) laid in trenches perpendicular to U/G cable for cable protection complete all as specified. |
| 64 | Supply, spread and filling approved sand in cable trenches for cushioning of LT UG cable complete all as specified and directed. Note: Punned thickness only will be measured and paid |
| 65 | M&L for 40mm bore GI pipe light grade with all necessary fittings (ISI marked) as in cable protection fixed to pole,laid in trenches/road/floor complete all as specified and as directed. |
| 66 | S&F PVC square box 100mm x 100mm including replacement of old unserviceable one and refixing of old switch socket complete all as specified and as directed. |
| 67 | S&F PVC square box 170mm x 100mm including replacement of old unserviceable one and refixing of old switch socket complete all as specified and as directed. |
| 68 | S&F PVC square box 200mm x 150mm including replacement of old unserviceable one and refixing of old switch socket complete all as specified and as directed. |
| 69 | S&F PVC square box 300mm x 250mm including replacement of old unserviceable one and refixing of old switch socket complete all as specified and as directed. |
| 70 | S&F medium grade, PVC casing and capping duly fixed with casing pins and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. |
| 71 | S&F medium grade PVC Conduit duly fixed with Clamps on wall surfaces and connecting accessories like Tee , Bends , elbow etc required as per site complete all as direced. |
| 72 | M&L earthing with GI earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25m below the ground level with top edge of earth plate at a depth not less than 1.5m below the ground level connected to galvanized iron wire 4mm dia earth lead by means of bolts & nuts,check nuts & washers made of galvanised steel, earth wire protected by and including PCC (1:3:6) type C2 precast RCC cover slab (1:2:4, type B1)reinforced with 8mm dia TMT bars 100mm center to center bothways including one handle made of 10 mm dia round bar, including necessary excavation and earthwork in any type of soil, 20 mm dia light grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth wire GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 5 of SSR Part 1 and connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed.Note: The unit rate includes for protection pipe and GI stip dia from top of earth plate upto 7.00 meter above ground level. |
| 73 | Refixing surface point wiring for light/fan/bell, buzzer points controlled by one, one way switch complete controlled by one way switch 5/6 amps complete with 1.5 Sqmm multistranded copper conductor single core PVC insulated unsheathed cable 1100 volts grade with proper colour coding drawn through and including non-metallic rigid PVC casing capping medium grade with accessories (ISI marked) fixed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable as earth continuity conductor connected to common earth dolly, fabricated suken terminal box made out of MS sheet steel for boxes duly painted with aluminum inside and anticorrosive paint outside,(clear depth of the box not less than 60mm and this shall be increased suitably to accomadiate flush type regulators) concealed in walls, with 3mm thick bakelite/plastic laminated sheet top cover fixed with cadmium plated iron screws for housing switches, socket outlets, fan regulators etc duly earthed complete all as specified and as directed.Notes:-(i) Serviceable wire and suken terminal box made out of MS sheet steel for boxes obtained from item No. 1 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted(iii) Connections of cable with MCBs or bus bar shall be sone through proper size of copper/brass thimbles. |
| 74 | All as per item No 72 here-in-above but One socket out let 5/6 amps point on the same board |
| 75 | All as per item No 72 here-in-above but One socket out let 5/6 amps point on the independent board |
| 76 | Description all as per item No 72 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and including 2.5 sqmm multi stranded copper conductor as continuous earth wire with lugs complete all as specified and directed. |
| 77 | Refixing Sheet metal enclosure for 4/6/8/12 way Distribution Boards (DB’s), double door, Single pole & neutral with 200 Amps rated bus bar, 240 Volts,IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directedNote:- Serviceable SPN DB;s obtained from item No. 2 here-in-before shall fixed |
| 78 | Refixing Sheet metal enclosure for 4/6/8/12 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 Amps rated bus bar, 415 Volts,IP-43 protection, complete including. blanking plates as required & flush to wall/other surface complete all as specified and as directedNote:- Serviceable TPN DB;s obtained from item No. 2 here-in-before shall fixed |
| 79 | Refixing MCB, FP, 63 Amps complete all as specified and as directedNote:- Serviceable MCB;s obtained from item No. 2 here-in-before shall fixed |
| 80 | Refixing MCB, SPN, B-Curve 32 Amps complete all as specified and as directed |
| 81 | Taking down and refixing MCB, B- series SP, 6-32 Amps complete all as specified and as directedNote:- Serviceable MCB;s obtained from item No. 2 here-in-before shall fixed |
| 82 | Refixing only Earth and Plug socket with MCB 25 Amps of any rating and flush to wall/other surface complete all as specified and as directedNote:- Serviceable Earth Plug obtained from item No. 2 here-in-before shall fixed |
| 83 | Fixing only Surface type sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth wire,PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i) Serviceable wire and obtained from item No.3 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted (iii) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (iv) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 84 | Fixing only Surface type sub-main wiring alongwith earth wire of size of 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire,PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC casing capping medium grade with accessories (ISI marked) and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i) Serviceable wire and obtained from item No.3 here-in-before shall be reused (ii) Cost of PVC casing capping with accessories is deemed to inclusive in Unit rate Quoted (iii) Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (iv) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 85 | Taking down and refixing LED luminaire 18/20/35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp 1 x 20 W, 220 V, AC decorative box type with driver, holder including LED driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 86 | Taking down and refixing ceiling fans kwith blades, down rods and accessories, 230 V any sweep complete all as directed |
| 87 | Taking down and refixing exhaust fan single phase 230 v of any sweep with blades and frame and louvers for repair including making hole and good disturbed surfaces fixing with fastnuts, properly clamped louvers complete all as directed |
| 88 | S&F PVC insulated sheathed multicore cable copper conductor 1.00 Sqmm, 2 Core complete all as specified and as directed |
| 89 | S&F PVC insulated sheathed multicore cable copper conductor 1.50 Sqmm, 3 Core complete all as specified and as directed |
| 90 | S&F PVC insulated sheathed multicore cable copper conductor 2.50 Sqmm, 3 Core complete all as specified and as directed |
| 91 | S&F in replacement Modular Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 92 | S&F in replacement Modular Switch 1 way 16 Amps, 1 module, complete all as specified and directed. |
| 93 | S&F in replacement Modular Socket 6 Amps, 5 pin, 2 module, complete all as specified and directed. |
| 94 | S&F in replacement Modular Switch Socket 6 A/ 16 Amps, 6 pin 2 module complete all as specified and directed. |
| 95 | S&F in replacement Modular Bell Push Switch 1 way 6 Amps, 1 module, complete all as specified and directed. |
| 96 | S&F in replacement Modular Blank plate, 1 module, complete all as specified and directed. |
| 97 | S&F in replacement Modular fan regulator, step type, 120 watt, 2 module, complete all as specified and directed. |
| 98 | S&F in replacement Modular Switch two way 5/6 Amp, 1 module, complete all as specified and directed. |
| 99 | S&F in repair, VTPN DB, 08 Way, double door,Metal door ,IP-43 IK 09, with MCCB as(upto 160 Amps) incomer, and MCB;s as Outgoing , 250Amps rated copper bus bars,earth bar,neutral links, no. of module complete including blanking plates as required & fixed flush to wall and making good the disturbed surfaces including complete all as specified and as direct. Note:- MCCB;s/MCB's required as Outgoing shall be measured and pair seperately under appropiate items |
| 100 | S&F in repair, MCCB 4P 125 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KA complete all as specified and as direct. |
| 101 | S&F in repair, MCCB 4P 100 Amps,thermal magnetic release, 415V ,50 Hz ,breaking capacity 25 KA complete all as specified and as direct. |
| 102 | S&F cable end termination kit for LT 1.1 KV Cable for Cable 25 to 50 Sqmm 3.5 Core cable in existing and new cables as directed by Engr-in-Charge complete all as specified and directed. |
| 103 | S&F in repair, trim cosmo surface round slim surface mounted LED luminarie 12 Watt, (or next nearer higher watt) 6500K with diffuser to ensure glare free and even light distribution & integrated electronic driver, with all accessories, suitable for operation on AC, single phase 220 / 230 Volts, 50 Hz supply, including removal of old unserviceable fitting complete all as specified and as directed. |
| 104 | S&F in repair, trim cosmo Square slim surface mounted LED luminarie 12 Watt, (or next nearer higher watt) 6500K with diffuser to ensure glare free and even light distribution & integrated electronic driver, with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, including removal of old unserviceable fitting complete all as specified and as directed. |
| 105 | S&F in repair, octane LED 600mm x 600mm ultra slim recessed mounted LED module with high brightness, de-glaring PP diffuser and PS LGP de-glaring sheet for glare free uniform light distribution suitable for grid ceiling LED luminarie 40 Watt, (or next nearer higher watt) 6500K with diffuser to ensure glare free and even light distribution & integrated electronic driver, with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, including removal of old unserviceable fitting complete all as specified and as directed. |
| 106 | M&L for AC socket with MCB, DP 25 Amps, starter switch and socket with plug Top and indicator complete all as specified and directed. |
| 107 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 108 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 109 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid casing caping of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 110 | M&L Concealed sub-main wiring alongwith earth wire of size of 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid casing caping of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i)Two runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED |
| 111 | S&F LED luminarie tube light fitting basic all purpose surface/wall mounted decrotative slim with polycarbonate housing & integrated electronic driver, 4 feet LED with high efficient LEDs 20 watt, (or nearest next higher wattage) with all accessories, suitable for operation on AC, single phase 220/230 Volts, 50 Hz, 3000K complete all as specified and as directed. |
| 112 | S&F in repair, Round slim surface mounted LED luminarie 18 Watt, (or next nearer higher watt) 6500K with diffuser to ensure glare free and even light distribution & integrated electronic driver, with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed. |
| 113 | S&F in repair, Square slim surface mounted LED luminarie 18 Watt, (or next nearer higher watt) 6500K with diffuser to ensure glare free and even light distribution & integrated electronic driver, with all accessories, suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed. |
| 114 | S&F in repair, Square slim recessed mounted LED luminarie 40 Watt, (or next nearer higher watt) 3000K, ceiling cut out 210mm x 210mm, with opal diffuser & integrated electronic driver, with all accessories, prewired suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed. |
| 115 | S&F in repair, Flameproof cum Waterproof LED Bulk Head light fitting of 150 Watt, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish (CIMFR-BIS-PESC0 cetified, recomended for Gs IIC, Zone 1& 2, temperature Class T6) complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 116 | S&F in repair, Flameproof cum Waterproof LED Bulk Head light fitting of 60 Watt, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish (CIMFR-BIS-PESC0 cetified, recomended for Gs IIC, Zone 1& 2, temperature Class T6)complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 117 | S&F in repair, LED light fitting 1x 20 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 118 | S&F in repair, LED well glass light fitting 35Watt flame proof, CMRI certified recommended and IP 66 protection, 120 lumems per watt, with die cast canopy and gear housing, versatile well glass series with both eye bolt and cardle for mutliple mounting option, complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. |
| 119 | S&F in repair, Square slim recessed mounted LED luminarie 18 Watt, (or next nearer higher watt) 6500K, ceiling cut out 210mm x 210mm, with opal diffuser & integrated electronic driver, with all accessories, prewired suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed. |
| 120 | S&F in repair, round recessed mounted down light, LED luminarie 18 Watt, (or next nearer higher watt) 6500K, ceiling cut out 95mm, with pressure die cast aluminum heat sink and clear PC cover in white powder coated finish & integrated electronic driver, with all accessories, prewired suitable for operation on Ac, single phase 220 / 230 Volts, 50 Hz supply, complete all as specified and as directed. |
| 121 | S&F in repair, recess mounted LED luminarie 36 Watt,(or next nearer higher watt) size 4 feet x 1 feet, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminarie with high brightness SMD LEDs as light source with all accessories, suitable for 220/230 Volts, 50 Hz,complete all as specified and as directed. |
| 122 | M&L Concealed sub-main wiring alongwith earth wire of size of 4 x 6.00 sq. mm + 1 x 6.00 sq. mm earth wire, ISI marked, FRLSH, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of suitable size with all fittings and accessories (ISI marked) of suitable size with all fittings and accessories ISI marked including cutting chases in wall, floor etc and making good to walls, floors etc as per existing specifications complete all as specified and as directed. NOTE : (i) Four runs of PVC wire, one run of earth wire & one run of PVC Conduit will be measured as one length. (ii) Loop length as required and as directed deemed to be included in the UNIT RATE QUOTED Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysSep 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender