Tender For Special Repair To Toilets Of Arjun And Pratap Billets At 3 Brd Under Ge (Af) Mc Chandigarh

BOQ

Name of Work:- SPECIAL REPAIR TO TOILETS OF ARJUN AND PRATAP BILLETS AT 3 BRD UNDER GE (AF) MC CHANDIGARH
Sl. No. Item Description
1Demolition of lime concrete / lean concrete /Brick bats etc from sunken slab portion exc. 15 cm thick but above ground floors, complete all as specified and directed by Engineer-in-charge including removal of demolished material and debris away from site a location designated by local administration up to a distance 1.5 km from site. complete all as specified and directed by Engr-in-charge.
2M & L for 25 mm thick cement concrete (1:2:4) type B-0 using 12.5 mm graded crushed stone aggregates as in flooring laid in slope complete all as specified and directed by Engineer- in-charge.
3M&L lean concrete type E-2 (1:5:10) using 40mm bricks bats aggregate as in sunken portion complete all as specified and directed by Engineer-in-charge.
4M & L for Spout pipe for sunken work made out of 40 mm dia medium grade Galvanized Iron pipe complete all as specified and directed by Engineer-in-charge.
5M&L for providing water proofing treatment of sunken portion of WCs, bathroom etc. by applying cement slurry mixed with Acrylic based polymer modified cementitious composite compound coating of make as approval in Technical Instruction 5/2003 by providing: (a) 15mm thick plaster (1:4) cement sand mortar with integral water proofing compound @ 2% by weight of cement on floor and wall / beam , finishing the surface even and smooth without using extra cement. The surface shall then be cured and allowed to dry. (Note: Water proofing compound shall be measured and paid separately). (b) First layer of slurry of cement @0.5 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.25 kg/sqm. This layer will be allowed to air cure for 4 hrs. (c) Second layer of slurry of cement @0.25 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.15 kg/sqm. This layer will be allowed to air cure for 4 hrs followed with water curing for 48 hrs. complete all as specified and directed by Engineer-in-charge.NOTE : Floor area of the sunken slab shall be measured only.Make of Acrylic based polymer modified cementitious compound -Dr.fixit/Fosroc ( Brushbond) /Sika (Sikatop-100)
6Supply only water proofing compound ISI marked complete all as specified and directed by Engr-in-Charge.
7M & L for super gloss finished/carving (PGVT) tiles external/Internal in vertical surfaces 600mm x 1200mmx 7 to 8mm thick over & including 10mm thick rendering in Cement Mortar 1:4 set and jointed in neat cement slurry or tile adhesive and pointed in white or coloured cement to match including dismantling existing tile and removing the debris outside the defence land complete all as specified and as directed. Make: Orient ceramic/H&R Johnson/Kajaria etc.
8M & L for Non - skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and Including 15 thick screed bed in Cement Mortar 1:6 and dismantling of existing tiles complete all as specified and directed by Engr-in-charge.
9M&L for Non-skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and Including 15 thick screed bed in Cement Mortar 1:6 and dismantling of existing tiles complete all as specified and directed by Engr-in-charge.
10M&L for , Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick as in skirting, dados, risers to steps, etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles ,10 mm thick for wall finished in Cement Mortar 1:4 , including dismantling floor hearth or wall tiling incl cement mortar bedding ( but not backing ) removal of rubbish off the premises debris away from site to a designated point by local administration or a distance up to 1.5 km from site complete all as specified and directed by Engr-in-charge.
11S&F in repair 100 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, complete all as specified and directed by Engr-in-charge.
12All as per item No. 11 here-in-before but 75 mm dia
13Fixing only in repair 100 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, after necessary cleaning complete all as specified and directed by Engr-in-charge.
14Fixing only in repair 75 mm cast iron soil waste and vent pipe in any length with or without ears jointed with cement mortar (1:3) fixed to wall , laid in trenches or in floors, after necessary cleaning complete all as specified and directed by Engr-in-charge.
15S&F 100 mm dia cast iron bends in repair complete all as specified and directed
16All as per item No. 15 here-in-before but 75 mm dia after necessary cleaning complete all as specified and directed
17S&F Branch pieces, single (equal or unequal),ordinary or inverted(spigot or socket type)or with parallel branches 100 mm dia complete all as specified and directed by Engr-in-charge.
18S&F Branch pieces, single (equal or unequal),ordinary or inverted(spigot or socket type)or with parallel branches 75 mm dia complete all as specified and directed by Engr-in-charge.
19S&F cast iron cowls 100 mm dia as in repairs complete all as specified and directed by Engr-in-charge.
20S&F cast iron cowls 75mm dia as in repairs complete all as specified and directed by Engr-in-charge.
21S&F in repairs 75 mm dia cast iron Floor Trap/Nahani Trap ,with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engr-in-charge.
22S&F in repairs 100 mm dia cast iron Floor Trap/Nahani Trap ,with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engr-in-charge.
23Fixing only in repair 100 mm cast iron bends/Tee/cowls after necessary cleaning complete all as specified and directed by Engr-in-charge.
24Fixing only in repair 75 mm cast iron bends/Tee/cowls after necessary cleaning complete all as specified and directed by Engr-in-charge.
25M & L for Cutting holes into or through brick walls built in cement mortar or cement lime mortar having superficial area not exceed 150 Sqcm each. making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1. complete all as specified and directed.
26Cleaning of tree including cutting of trunk portion protruding over wall surface/roof surface/terrace of building of height up to 10.0 mtr. Including necessary scaffolding and necessary safety measure if required and make good the surface in cement mortar (1:3) and applying one coat of anti growth of vegetation chemical as directed by Engr-in-Charge and removing of unserviceable material out side MD land and cleaning site complete all as specified and directed by Engr-in-Charge
27S&F in repair PVC (SWR) pipes 160mm dia Single socketed, in any length with rubber ring joints fixed to walls , laid in trenches, floors.etc complete all as specified and directed by Engr-in-charge.
28S&F for 160mm PVC (SWR) bends any radius complete all as specified and directed by Engr-in-charge.
29S&F in repair for 75 mm PVC (SWR) pipes single socket in any length with rubber ring joints, laid in trenches, wall, floors or laid in sunken floors, walls etc complete all as specified and directed.
30S&F for 75 mm PVC bends, branch piece or similar fitting as required to make the system functional complete all as specified and directed.
31S&F for 75 mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
32Taking up or down GI steel/ Kitek tubing 15 mm with connections or fittings from wall, ceiling, floor etc complete all as specified and directed.
33Taking up or down GI steel/ Kitek tubing 20 mm with connections or fittings from wall, ceiling, floor etc complete all as specified and directed.
34S & F GI water tubes, 15 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
35S & F GI water tubes, 20 mm bore medium grade, galvanized with all fittings and fixed complete to walls, ceiling or laid in floors complete all as specified and directed by Engr-in-charge.
36Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding n exc 150 sqm girth complete all as specified and directed.
37S&F in repair Vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm, white colour, with integral foot rests (excluding flushing cistern and flush pipe), including 100mm 'P' or 'S' trap set complete all as specified and directed.
38S&F in repairs vitreous china wash down water closet pan (pedestal pattern ) including connection to drain and flushing pipe antisyphonic pipes etc complete all as specified and directed.
39S&F in repair PVC syphonic action type flushing cistern 10 lts capacity ,low level with inlet ,ball valve float and bracket with complete fitting complete all as specified and directed .
40S&F in repair 15 mm fancy type Stop valves cast copper alloy chromium plated with long shank and Cup ( Concealed Type) screwed down high pressure with crutch both ends for iron pipes or for union complete all as specified and directed.
41S&F in repair 15 mm fancy type angle valves cast copper alloy screwed down high pressure with crutch both ends for iron pipes or for union complete all as specified and directed.
42S&F in repair 15 mm Bib taps long body cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed.
43S&F in repairs 15 mm brass chromium plated wall mixer (three-in-one) for mixing Hot and Cold water screwed down for iron pipes for complete all as specified and directed.
44S&F in repairs 15 mm brass chromium plated centre hole WHB mixer with connection pipe for mixing Hot and Cold water screwed down for iron pipes complete all as specified and directed.
45S&F in repairs for Vitreous China under counter basin wash basin, white or ivory colour flat back, size 470mmx350mm excluding taps, waste chain and plug and porcelain stopper but including brackets any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe etc fixed complete all as specified and directed.
46S & F for 5.50mm thick mirror of selected quality glass with edge moulding, mounted on wall fixed with SS stud fixed complete all as specified and directed.
47S&F PVC connection 15 mm size with PTMT nuts of length 450 mm long complete all as specified and directed.
48S&F PVC connection 15 mm size with PTMT nuts of length 600 mm long complete all as specified and directed.
49S&F health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
50S&F in repairs Chromium plated shower roses with shower 150mm dia swivel shower brass chromium plated with arm 100 mm size for fixing with 15 mm pipes with swivel joints ,any size including fixing to steel pipes or union complete all as specified and directed.
51S&F in repairs for PVC waste pipe 32mm dia, complete with 80 cm long flexible for WHB/Urinals fixed complete all as specified and directed.
52Taking down cement plaster of any description on brick or stone walls etc, including raking out joints, hacking for key scrubbing down with water, etc , complete all as specified and directed by Engr-in-Charge. .
53M&L for Rendering 15mm thick in Cement Mortar 1:4 on brick work, concrete, R.C.C. Surfaces on mumty , parapet or similar surfaces at any height finished even and fair without using extra cement of ,up to height 12 mtr , including necessary scaffolding complete all as specified and directed by Engr-in-Charge.
54M&L Rendering 15mm thick on brick surfaces of wall in cement mortar (1:6), finished even and smooth without using extra cement, cement plaster and racking out joints, hacking for key scrubbing down with water etc , complete all as specified and directed by Engr-in-Charge
55M&L for Rendering 10 mm thick in cement mortar (1:4) on ceiling, parapet, chajjas, facias of building and finished the surface even and smooth without using extra cement, complete all as specified and directed by Engineer-In-Charge. .
56M&L preparation of new plaster surfaces of walls and applying two coat of oil bound distemper white or tinted over a coat primer and a coat white putty complete, all as specified and directed by Engr-in-Charge
57M&L for preparation of new plaster/un treated surface of wall / coloum ,beam , chajja etc. and leveling / edgesing the disturbed surface and apply two coat of exterior acrylic emulsion (weather proof treatment) over a coat primer and a coat of water proofing putty , to be applied using an airless spray machine , complete all as manufacturer's instruction and as directed.
58M&L preparation of new surface of ceiling and applying two coat of oil bound distemper over a coat of white putty, white or tinted complete all as specified and directed by Engr-in-Charge
59M&L for Rough cast plaster after applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (which is generally of size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure that larger aggregates are thoroughly covered complete all as specified and directed, including taking down existing cement plaster any layer and racking out joints, hacking for key scrubbing down with water etc, complete all specified and directed by Engr-in-Charge NOTE:- WPC shall be measured and paid separately
60Taking down chowkhat or frame n .exc. 1.5 sqm each without taking off shutter from the frame complete all as specified and directed.
61S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification complete all as specified and directed.
62S&F Factory made Solid PVC moulded Door Shutter 28 to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick Moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face with particle board core , supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
63Supply and Fix, Aluminium anodised, barrel tower bolts 150 mm long, powder coated, of extruded section and fixed, complete all as specified and directed.
64S&F Aluminium handles, cast type, anodised 100mm in size fixed with screws complete all as specified and directed.
65Supply and fix, butt hinges, 100mm long, miled steel with stainless steel hinge pin, complete all as specified and directed.
66Taking down shutter of any description not exceeding 1 Sqm each complete all as specified and as directed.
67Taking down shutters exe 1 sqm but n exc 2 Sqm each complete all as specified.
68S & F for 30mm thick flush shutters, solid core construction, with block core plywood face panels, commercial type on both sides, chemically treated against termite infestation complete all as specified and directed.
69S & F for 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkhat
70Supply and Fix, Aluminium anodised, barrel tower bolts 200mm long, powder coated, of extruded section and fixed, complete all as specified and directed.
71Supply and fix, Aluminium alloy, anodised, Sliding door bolts 200mm long, with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy 12mm dia, complete all as specified and directed.
72S&F Aluminium handles, cast type, anodised 150 mm in size fixed with screws complete all as specified and directed.
73M & L for preparation of new or previously untreated steel surface of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
74M&L for preparation of new wooden surfaces or old of any description and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified.
75Material and labour for hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
76Supply and fix plain sheet glass 3mm thick, ordinary quality, not exceeding 0.50Sqm in each pane, and glazing with oil putty and securing pins, spring clips etc, complete all as specified and directed.
77S&F in repair Galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples complete all as specified and directed.
78S&F Galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanized wire staples complete all as specified and directed.
79M&L for preparation of old surface including by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots on the wall and applying two coat of oil bound distemper white or tinted over a coat of wall care putty , to be applied using an airless spray machine, after covering of window glass, door shutter and electric point/ appliances with help of polythene/news paper complete all as specified and directed by Engr-in-Charge.
80M&L for preparation of old plastered /concrete surfaces of ceiling and applying one coat of oil bound distemper, white or tinted over a coat of white putty) ) up to 12 Mtr height including necessary scaffolding etc complete all as specified and directed.Note:- Application of distemper shall be with the help of a roller only.
81M&L for preparation of old plastered surfaces including by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil, greasy spots on the wall and leveling / edgesing the disturbed surface with water proofing putty and applying two coat of exterior acrylic emulsion weather proof treatment over a coat of water proofing putty upto 15 Mtr height to be applied using an airless spray machine including necessary scaffolding etc complete all as specified and directed.Note : The tint and shade be as approved by the GE.
82Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles and removing the debris outside the defence land complete all as specified and as directed.
83M&L for Brick work with sub Class ‘B’ bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 in any location, complete all as specified and as directed.
84S & F PVC (SWR) gully trap 150/110 mm,setting and jointing with solvent cement complete all as specified and as directed.
85S & F for providing, lowering and laying HDPE DWCPE (SN8) pipes as per IS : 16098 of 2013, 150 mm bore, laid and jointed with and including elastomeric sealing 'O' ring as per manufacturer's instructions. incl Plain cement concrete type C-2, 1:3:6 using 40mm graded stone aggregate as in concrete bed including packing under & haunching against sides of pipes after the pipes are laid and tested and including demolition of existing pipe. complete all as specified and directed by the Engineer -In –charge(Note - The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.The rates include for all necessary extra joints, waste, and cutting etc.)
86Material and labour for cleaning and removal of dust,mud,algae,moss and other stains from roof tiles(brick/concrete) and parapet with help of wire brush or mechanical means including scrubbing down with water. removal of all rubbish outside the defence land, complete all as specified and directed.Note:- It shall be ensured by the contractor that there is no damage to the existing arrangement on roof.
87Material and labour for brushing neat cement slurry with 3.0kg of cement per sq. mtr complete all as specified and directed. Note:- It shall be ensured by the contractor that there is no damage to the existing arrangement on roof
88Material and labour for rendering 20mm thick in cement mortar (1:3) using WPC @ 200ML per 50Kg bag of cement on surfaces of roof and parapet, finished even & fair without using extra cement, Ensuring no damage arrangement fixed on roof, complete all as specified and directed. Note:- It shall be ensured by the contractor that there is no damage to the existing arrangement on roof
89Supply only Liquid water proofing compound complete all as specified and directed by Engineer-in-charge.
90M & L for providing, mixing and applying Dr.fixit/Fosroc Primer AC with 10% water dilution with clean portable water, and applying with roller or brush coverage at the rate 7.0 to 8.0 sqm per litre/coat.allow the primer to dry for 04 hrs.And applying a coat of Dr.fixit/Fosroc roof seal select (diluted with water in the ratio 2:1) self priming coat at the rate 8-10 sqm/litre/coat in the SSD condition.Apply 1st coat of Dr.fixit/Fosroc roof seal select at the rate of 0.45-0.5/litre/sqm/coat. Laying a 45 Gsm glass fibre mesh of 2.5mmX2.50mm sandwiched between the first and second coat.While the first coat is still wet. Allow the first coat to dry for 4-6 hrs.Apply second coat of Dr.fixit/Fosroc roof seal select with the same application coverage. Application direction of second coat coat should be perpendicular to the first coat .Allow second coat to dry for 4-6 hrs.Apply third coat of Dr.fixit/Fosroc roof seal select at an application direction that is perpendicular to that of the second coat with the same application coverage rate to achieve total dry film thickness of 900 to 1000 microns at forced coverage at the rate of 1.50-1.60 litre/sqm in 3 coats. check to see no void surface is untreated/uncoated. Allow the system to air cure for 7 days minimum. The material having following technical properties: Attains a tensile strength with fibre N/mm 2=6-8 as per ASTM D 2370; Elongation at break = 200% as per ASTM D 2370, Crack bridging ability up to 2mm,Shore-A hardness 80 as per ASTM D2240-2015,Tear Resistance with fibre N/mm 34 as per ASTM D 624. The system comes with 12 year waterproofing warranty from M/S Pidilite Industries/FOSROC. Complete all as specified and directed by Engineer-in-charge.
91S & F in repair rotational moulded polyethylene water storage tank (Cylindrical vertical with close top), HDPE, triple layered white colour with ISI marked of 2000 ltrs capacity with inlet & outlet connections, including 20mm dia PVC float valve with ball & all fittings, tank nipple with washer & plug , with tank lid having locking arrangement hoisted and fixed in position complete all as specified and directed including dismantling existing water storage tanks (RCC/PVC) of capacity upto 500 litre complete all as specified and directed by Engineer-in-charge.
92M&L for disconnecting of PVC tank of capacity 2000 Ltrs for tank cleaning all as specified and directed :-a) Dewatering & removing all settled silt, scale & dust from inside of tanks using coconut brush manually and applying bleaching powder and allowed to rest for 1 hour.b) Cleaning & rinsing the tank using fresh water to wash out complete and allowed to dry for 30 mins.c) Writing letters of 7 cm height using synthetic enamel paint (white colour) to mention date of cleaning including rubbing out old letters written over the tankd) Refixing the tank in same position or raised/lower height after cleaning or water proofing treatment (as may necessary) complete all as directed by Engr-in-charge.Note : - Water proofing treatment, PCC bench, pipes if required to be replaced shall be measured and paid separately under relevant items.
93Material and labour for cement concrete (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregate, as in roof kerb, mud stops, benching ,padding on chhajjas including use and waste necessary form work and scaffolding up to 7mtr height complete all as specified and directed.
94Taking down carefully aluminum/copper point wiring (light ,fan, socket any type, power, bell etc. complete including fixtures & fittings (such as ceiling rose, socket, Pendent, regulator, light fitting etc) and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as directed.
95M & L for Concealed Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLSH) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic UPVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall / roof incl cutting & chases and modular flush metal boxes 0.8 mm thick suitable for modular fittings including modular outer cover plate make Legrand (Arteor)/ Schneider (Zencelo) /Anchor (panasonic Thea)/Goldmedal(Nixon Quorra) with inner frame suitable for cover plate as per site requirement for mounting modular switches, sockets, etc including earth wire of PVC insulated (FRLSH) copper conductor multistranded of 1.5 Sqmm size in green colour including making good the disturbed wall/ceiling surfaces after completion of concealed wiring work, by filling the chases with suitable cement mortar/plaster and finishing to match the existing surface, including necessary puttying and painting/finishing to match the existing finish, complete all as specified in current SSR Part-I & II all as directed, as described below:-
96One light point/exhaust/ceiling fan/bell controlled by one way switch 6 amp complete.
97One 3 pin 6 Amps socket point controlled by one switch on same board.
98One 3 pin 6 Amps socket point controlled by one Modular switch on independent board.
99All as per item No.2 but for 3 pin / 5 pin 16 Amps sockets outlet with 2.5 Sqmm PVC insulated & unsheathed (FRLSH) copper conductor cable independent complete all as specified and as directed.
100Supply and Fixing Modular switch 16/20 Amp single pole one way,2 Module with indicator and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the important parameters like rating etc should be laser printed on every switch along with catoulage number all as specified. Make: Legrand (Arteor) / Schneider (Zencelo) / Anchor(Panasonic Thea)/Goldmedal(Nixon Quorra)
101Supply and Fixing Modular socket shutter type, 2-in-1,3 and 5 pins 6 /16 Amps, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue number complete all as specified. Make: Legrand (Arteor) / Schneider (Zencelo) / Anchor (Panasonic Thea)/Goldmedal(Nixon Quorra)
102Supply and Fixing in replacement Ceiling rose surface Bakelite 65mm x 50mm three terminals ,ISI marked complete all as specified.
103Supply and Fixing in replacement Modular switch 6 Amps single pole one-way, 1 Module and no top gap between rocker plate and fully shrouded double rocker mechanism type all the important parameters like rating etc should be laser printed on every switch along with catalogue number complete all as specified. Make: Legrand (Arteor) / Schneider (Zencelo) / Anchor(Panasonic Thea)/Goldmedal(Nixon Quorra)
104Supply and Fixing in replacement modular socket shutter type, 2-in-1, 3 pins 6 Amps, ISI marked, combined 2 Module and no top gap between rocker plate and fully shrouded double rocker mechanisam type all the important parameters like rating etc should be laser printed on every switch along with catoulage number complete all as specified. Make: Legrand (Arteor) / Schneider (Zencelo) / Goldmedal(Nixon Quorra)
105Supply and fixing in replacement indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light complete fitting 1x 20 watt LED Tube fitting with aluminium channel housing & integrated electronic driver, energy efficient, 140V-270 volts, Warm/natural/cool as per site requirement type >110 Lm/Watt complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified.
106Supply and fix in repair of Exhaust fan 380mm sweep, copper winding, 1900 CMH,90 W,4 blades with aerodynamic design , Mettallic type along with GI louvers complete suitable to work on AC, single phase, 230 Volts, 1400 RPM , 50 Hz supply and including cutting of hole in wall of suitable size and connecting up with three core twisted flexible copper conductor cable of suitable size 0.75 Sqmm all as specified and directed.Make : CG/Havells/V Guard/ Gold Medal/Usha
107Material and labour for Sub Main Wiring with two run single core 6.0Sqmm (nominal area) multi stranded copper conductor FRLSH PVC insulated and unsheathed 1100volts grade colour code cables, drawn concealed including PVC conduit of 25mm dia bore medium grade, including standard fittings such as Tees, junction, bends etc., with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed 1100volts grade colour code cable for earth continuity and making good the disturbed wall/ceiling surfaces after completion of concealed wiring work, by filling the chases with suitable cement mortar/plaster and finishing to match the existing surface, including necessary puttying and painting/finishing to match the existing finish including taking down old, complete all as specified and directed.Note:- Two run of 4Sqmm + One run of 4Sqmm for earth wire shall be measured as one RM.
108Supply and fixing in replacement of MCB DB Single pole and neutral 08 way sheet steel phospehtised powder concealed painted with IP 43 protection 240 V neutral link, earth bar and Din rail double door and making good the disturbed wall/ceiling surfaces after completion of concealed wiring work, by filling the chases with suitable cement mortar/plaster and finishing to match the existing surface, including necessary puttying and painting/finishing to match the existing finish complete all as specified and directed.Make: Goldmedal/Legrand/Havells
109Supply and fix in replacement SPN 40- 63 Amps,' C' curve , bracking cap10KA, 240V complete all as specified.
110Supply and fixing in replacement of MCB Single pole 6 to 32 Amp, 240V, 10KA, 'B' curve with indicator light complete all as specified & directed. Make:- Gold medal/Havells/Legrand
111Supply and fixing of water storage heater vertical (geyser) with inner Tank Material: Blue Diamond Glass Lined Tank- 2X Corrosion Resistance; Outer Body Material: ABS, Type: Storage ; Capacity: 50 Litres; AC 220-240 Volts, Wattage: 2000 Watts; with auto temperature cutoff, Pressure: 8 Bars ; BEE Rating: 5 Star complete including SS 304 pipe 600mm connections and safety valve for geyser all as specified and directed.Racold/Havells/Goldmedal/V Guard/Jaquar
112Note :- Amount of credit of Rs. 28945.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57476310
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44.66 Lakhs
LAST DATE 03-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Toilets Of Arjun And Pratap Billets At 3 Brd Under Ge (Af) Mc Chandigarh
Basic Detail
Tender No GE (AF) MC/CHD/T-52/2026-27
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 11 Sep 2026
Submission Date 03 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 44.66 Lakhs
Tender Fee 500
EMD 89320
Exemption Available
Document List
7af66cc2-871a-443a-9943-9c3def5440cc.html
BOQ_884503.xls
Tender52.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

7af66cc2-871a-443a-9943-9c3def5440cc.html

xls

BOQ_884503.xls

pdf

Tender52.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders