Tender For Repairs To Path , Hard Standing, Joint And B/R Works At 25 Ed Af Stn Deolali Under Ge (Af) Ojhar.
Tender Overview
Project Description
Tender For Repairs To Path , Hard Standing, Joint And B/R Works At 25 Ed Af Stn Deolali Under Ge (Af) Ojhar.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Sep-2026 | BOQCORRIGENDUM | BOQ | 01-Oct-2026 |
| 2 | 01-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 08-Oct-2026 |
| 3 | 24-Sep-2026 | BOQCORRIGENDUM | BOQ | 08-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MD land complete all as directed. |
| 2 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thick above or below ground level and removal of entire debris as ordered outside MD land complete all as directed. |
| 3 | Demolition of brickwork , block masonry or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of debris as ordered outside MD land complete all as directed. |
| 4 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness,in a height upto 9 Mts from floor level including cover fillets complete all as specified and as directed |
| 5 | Demolition of stone slabs and tiles of any description or thickness in floors, platform, aprons etc., laid, bedded and pointed in any mortar , stacking serviceable slbs at site and removal of entire debris as ordered outside MOD land complete all as directed. |
| 6 | Taking down carefully exsiting bitumen tar felt / existing water proofing treatment including plaster/exsiting PCC padding, wire brushing and cleaning of the surface of Roof,terraces including flashing and junctions of parapets/kerbs walls etc and removal of entire debris as ordered outside MD land complete all as directed. |
| 7 | M&L for plain cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in edges of coping including necessary form work complete all as directed. |
| 8 | M&L for PCC 1:2:4 type B-0 using 12.5mm graded crusher stone aggregate mixed with integral water proofing admixture @ 200 ml per bag of cement i.e Shali plastLW+ or STP No-1 or equivalent as in roof/roof kerb/cover concrete to water proofing finished even and smooth with out using extra cement complete all as specified and as directed .WPC shall be measured and paid separately). |
| 9 | Supply only Integral liquid Water Proofing Compound (ISI Marked) of Make : CICO, Acco Proof, Impermo, Aqua flex as approved. |
| 10 | M&L for Brick work with well burnt best quality locally available bricks, old size bricks, straight or curved on plan to any radius built in any description in cement mortar 1:6 complete all as directed |
| 11 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted stone masonry built in cement mortar 1:6 complete all as specified & as directed. |
| 12 | S&F Anodised aluminium snap grid frame work size 605x605 mm for false ceiling incl Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long all as specified & directed by Engr -in-charge |
| 13 | M & L Non asbestos fibre cement building boards 4 mm thick (one side embosed design), fixed or laid/ inserted to Aluminium grid frame work in ceiling with clips all as specified and directed. |
| 14 | M&L for cleaning the newly plastered surface thoroughly with wire brushes and providing water proofing treatment all as specified here in after :-(a) Bituminous primer @ 0.30 liter per SqM confirming to IS 3384-1986.(b) 3mm thick APP polymeric mambrane minimum weighing 3 kg/sqm of M/S TEXSA Ltd or M/S TIKI Asphalt hydro stop or IWL 3 Kg/Sqm membrane (one layer) laid by torch application method with overlaps of 100mm joints of traverse direction and 75mm at longitudinal direction duly thermofused by flame torch all as specified in application manuel of company.(c) Applying two coat of bituminous aluminium paint @ 200ml/sqm. |
| 15 | Demolition of existing treatment of any type and preparing the surface by cleaning the concrete surface with wire brush and a high pressure water jet and ensure that it is free of dust, oil grease, loose particles vegetation roots etc including material and labour for laying padding cement concrete in terrace 1:2:4 type B-0 (using graded stone aggregate) of 50mm average thickness maintaining 1:30 slope finishing with 10mm thick cement mortar 1:3 as specified and directed by Engr in charge. (ii) Smart Ultron Hybrid Polyurea (Slow setting) Terrace surfaces Preparation Minor cleaning work removal of loose concrete and filling cracks with polymer modified mortar using smart care RP or epoxy mortar . (iii) Supply and applying high performance polyurea elastometric waterproofing coating cold applied of spray /brush applied , smart care ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D2370 crack bridging ability of 3mm as per 12.6 N/mm2 as per ASTM D2370 crack bridging ability of 3mm as per ASTM C 1305, shore A hardness of min 75 as per ASTM D 2240 , The system includes final base preparation , epoxy primer application and appplying smart care ultron or approved equivalent in two coats at 1.2 kg per sqm etc complete as per manufacturer specification |
| 16 | M&L for 50 mm thick plain cement concrete 1:3:6 type C2 using 40mm graded crushed stone aggregate as in sub base to floor complete all as directed. |
| 17 | M&L for 150 mm thick Plain cement concrete,1:2:4 type B-2, using 40 mm graded crushed stone aggregates, laid in paths/PCC roads/hardstandings, including laying the concrete in alternate panels, with the area of each panel not exceeding 10 Sqm, properly compacting and finishing the surface to the required levels and gradients, and making impressions of expanded metal on the surface while the concrete is in green condition complete in all respects and to the entire satisfaction of the Engineer-in-Charge. |
| 18 | M & L for 75 mm thick plain cement conctere 1: 3 : 6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection finished the surface fair and even complete all as directed. Please Enable Macros to View BoQ information |
| 19 | M & L for 75 mm thick plain cement conctere 1: 3 : 6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection finished the surface fair and even complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender