Tender For Special Repair To Building No.T-09 (Otm Accn) In Zone-Iii At Lekhapani Mil Stn Under Ge Dinjan No.2
Tender Value
33.80 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
20 days left
EMD
67600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No.T-09 (Otm Accn) In Zone-Iii At Lekhapani Mil Stn Under Ge Dinjan No.2
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling wrought iron or mild steel work of any description comlpete all as specified and as directed by Engineer in Charge |
| 2 | Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings comlpete all as specified and as directed by Engineer in Charge |
| 3 | Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets comlpete all as specified and as directed by Engineer in Charge |
| 4 | Dismantling boarding, any description fixed in any position with nails comlpete all as specified and as directed by Engineer in Charge |
| 5 | Taking down roof trusses, coupled rafters or trussed beams of clear span above 4 mtrs and upto 8 mtrs comlpete all as specified and as directed by Engineer in Charge |
| 6 | Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position comlpete all as specified and as directed by Engineer in Charge |
| 7 | Dismantling timber fillets, rails, posts, rafters, purlins, etc in unframed work under 40 Sqcm in section in any posotion comlpete all as specified and as directed by Engineer in Charge |
| 8 | Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing comlpete all as specified and as directed by Engineer in Charge. |
| 9 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles comlpete all as specified and as directed by Engineer in Charge |
| 10 | Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) comlpete all as specified and as directed by Engineer in Charge |
| 11 | Demolition of RCC of any description in any position not otherwise specifically provided for comlpete all as specified and as directed by Engineer in Charge. |
| 12 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces comlpete all as specified and as directed by Engineer in Charge |
| 13 | Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces comlpete all as specified and as directed by Engineer in Charge |
| 14 | M&L for providing RCC 1:1 1/2:3,Type A-1 ( using 20mm nominal size graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete comlpete all as specified and as directed by Engineer in Charge |
| 15 | M&L for providing RCC 1:1 1/2:3,Type A-1 ( using 20mm nominal size graded crushed stone aggregate) as in chajjas comlpete all as specified and as directed by Engineer in Charge |
| 16 | M&L for providing RCC 1:1 1/2:3,Type A-1 ( using 20mm nominal size graded crushed stone aggregate) as in beams, cantilevers, bressumers,lintels over 1.5m span etc.complete including necessary form work comlpete all as specified and as directed by Engineer in Charge |
| 17 | M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for flat surfaces comlpete all as specified and as directed by Engineer in Charge |
| 18 | M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges comlpete all as specified and as directed by Engineer in Charge |
| 19 | M&L Form work to sides & soffits of lintels over 1.5m clear span, floor or roof beams, cantilevers, etc for rough finished flat surfaces of concrete comlpete all as specified and as directed by Engineer in Charge |
| 20 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia comlpete all as specified and as directed by Engineer in Charge |
| 21 | M & L for mild steel TMT bars 6 mm to 8 mm dia, in stirrups cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips comlpete all as specified and as directed by Engineer in Charge |
| 22 | M&L brick work with sub class 'B' bricks, straight or curved on plan exceeding 6m radius built in cement mortar 1:4 comlpete all as specified and as directed by Engineer in Charge |
| 23 | M&L for brick work with sub class old size 'B' bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls comlpete all as specified and as directed by Engineer in Charge |
| 24 | M&L for rendering 15mm thick in CM 1:4 on fair faces of brick or concrete surfaces in two layers 5mm thick finishing layer over 10mm thick backing layer finished fair and even with mixing water proofing compound to top layer as per manufacturers instruction and as directed (WPC will be measured separetely) comlpete all as specified and as directed by Engineer in Charge |
| 25 | Supply only Integral water proofing compound of approval brand comlpete all as specified and as directed by Engineer in Charge |
| 26 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of exterior wall care putty of 1 to 2 mm thick and applying two coats of cement base paint over a coat of primer comlpete all as specified and as directed by Engineer in Charge |
| 27 | M&L for rendering 15.mm thick plaster in cm 1:6 on fair faces of brick work or concrete surfaces including finishing top even and smooth without using extra cement comlpete all as specified and as directed by Engineer in Charge |
| 28 | M&L for preparation of new plastered surfaces of wall and preparing surfaces as directed by applying thin layer of wall care putty of 1 to 2 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer comlpete all as specified and as directed by Engineer in Charge. |
| 29 | S&F Pressed steel frames (125 x 60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., comlpete all as specified and as directed by Engineer in Charge. |
| 30 | M&L for plain cement concrete (1:3:6), type C-0, (using 12.5mm graded crushed stone aggregates) as in bed block, blocks for holdfasts, filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work comlpete all as specified and as directed by Engineer in Charge |
| 31 | S&F 35 mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match & fixed to chowkats comlpete all as specified and as directed by Engineer in Charge |
| 32 | S&F 35 mm thick, hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats comlpete all as specified and as directed by Engineer in Charge |
| 33 | S&F MS butt hinges,medium weight, cold rolled 100mm long fixed comlpete all as specified and as directed by Engineer in Charge |
| 34 | S&F MS butt hinges,medium weight, cold rolled 50mm long fixed comlpete all as specified and as directed by Engineer in Charge |
| 35 | Supply only 2nd Class hard wood small fittings such as brackets of any type ,latch and hinge blocks,shaped door and window stops and like ,including all necessary labours,articles n exc 200Cu.cm each comlpete all as specified and as directed by Engineer in Charge |
| 36 | S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples comlpete all as specified and as directed by Engineer in Charge |
| 37 | S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed comlpete all as specified and as directed by Engineer in Charge |
| 38 | S&F 150mm size aluminium handles, cast type, anodized and fixed comlpete all as specified and as directed by Engineer in Charge |
| 39 | S&F 300mm length of bolt, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy comlpete all as specified and as directed by Engineer in Charge |
| 40 | S&F 375mm long Mild steel ordinary rat tail rod pattern springs for door including roller and roller plate comlpete all as specified and as directed by Engineer in Charge. |
| 41 | S & F for aluminum powder coated (powder coated of required colour) three track sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.72 x 1.50mm (Soction of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc comlpete all as specified and as directed by Engineer in Charge |
| 42 | S & F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with CP brass/stainless steel screws @ 200mm centre to centre including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening comlpete all as specified and as directed by Engineer in Charge |
| 43 | Supply & Fixing mild Steel work in hollow square/rectangular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923 -1997 (Reaffirmed 2009) grade Yst.-310 comlpete all as specified and as directed by Engineer in Charge |
| 44 | Supply & Fixing plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cofirming to Fe 410 -W (Gde- E- 250) quality-A comlpete all as specified and as directed by Engineer in Charge |
| 45 | S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, longbut length of bolt exc 5cm but n exc 10cm long comlpete all as specified and as directed by Engineer in Charge |
| 46 | M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor comlpete all as specified and as directed by Engineer in Charge |
| 47 | M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor comlpete all as specified and as directed by Engineer in Charge |
| 48 | Supply and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights as per specifications comlpete all as specified and as directed by Engineer in Charge |
| 49 | M & L for 4 mm thick non asbestos fibre cement building boards fixed in ceiling flat or slope or laid/ inserted to timber/GI/Aluminium framework with screws etc complete all as per manufacturer instructions comlpete all as specified and as directed by Engineer in Charge |
| 50 | S&F MS works as in bands,straps, supports,hold fasts, wall and wind ties etc conforming to Fe-290 Gde-E-165 comlpete all as specified and as directed by Engineer in Charge |
| 51 | M&L for 75mm thick Cement concrete type C-1, 1:3:6 (using 20 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand 1:2 comlpete all as specified and as directed by Engineer in Charge |
| 52 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0kg of cement per sqm metre comlpete all as specified and as directed by Engineer in Charge |
| 53 | M& L for PCC 1:3:6 type C1 using 20 mm graded aggregate as in sub base floor comlpete all as specified and as directed by Engineer in Charge |
| 54 | M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick (squire / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in cement mortar 1:6 for laying floor finishes comlpete all as specified and as directed by Engineer in Charge |
| 55 | M&L for glazed ceramic coloured joint free tiles of 7mm thick on vertical surfaces such as skirtins, dados and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in cement mortar 1:4 comlpete all as specified and as directed by Engineer in Charge |
| 56 | M&L for preparing new wood & wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer comlpete all as specified and as directed by Engineer in Charge |
| 57 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer comlpete all as specified and as directed by Engineer in Charge. |
| 58 | S&F in repair curtain rods, anodised aluminium alloy, chromium plated with fixing brackets, stops, rollers etc comlpete all as specified and as directed by Engineer in Charge |
| 59 | S&F For Framed work such as grill ,gratings etc with ends of bars shouldered and or riveted,or forged into spikes,framed gurad bar,barred iron doors ,ladders,framed balusters,walk ways,railings,framework of water tanks and similar work conforming to Fe 290 Gde-E-165 |
| 60 | S&F 4mm dia plain mild steel wire galvanised class 3 in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes etc comlpete all as specified and as directed by Engineer in Charge |
| 61 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc comlpete all as specified and as directed by Engineer in Charge. Please Enable Macros to View BoQ information |
| 62 | Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc comlpete all as specified and as directed by Engineer in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender