Tender For Provision Of Cooler, Fridge, Geyser And Ac At Engr Bde Under Ge (West) Mathura
Tender Value
17.47 Lakhs
Estimated cost
Bid Submission
02 Oct 2026
19 days left
EMD
34948
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mathura → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of Cooler, Fridge, Geyser And Ac At Engr Bde Under Ge (West) Mathura
BOQ
| Sl. No. | Item Description |
| 1 | M&L for point wiring with 2.5 sqmm PVC insulated, unsheathed FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.2mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick hylam sheet cover for mounting switches, socket etc including 2.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for one socket 16 Amp socket outlet controlled by one switch on independent board complete all as specified and directed. |
| 2 | M&L for Point wiring complete with 4 sqmm single core FRLSH PVC insulated cable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light/fan point controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 4 sqmm multi stranded FRLSH, PVC insulaedcopper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed. |
| 3 | S&F socket out let, 3/6 pin suitable for 15 Amp plug top multipurpose 230 volt complete all as specified and directed. |
| 4 | S&F switch Piano flush type 15 amp single pole one way 230 volts all as specified & directed. |
| 5 | S&F desert cooler electric driven (single phase), having nominal air flow of capacity 5000 CuM per hour (or nearest) body made out bottom with 1.6mm thick and Top in 1.0mm thick with MS sheet including three set of side shutter complete all as specified and directed. |
| 6 | Supply, installation and testing of refrigerator electric driven, invertor compressor, direct cool, froast free, 295-310 litre stoarage capacity, free operation in range 140-260 VAC with 360 degree air flow, internal LED illumination with toughened and translucent shelving compartments and trays with external locking arrangement with key, minimum 5 star rating (as per latest specification of BEE effective) complete all as specified and as directed. |
| 7 | Supply, installation, testing & commissioning of electric storage water heater of 25 litre capacity, rated voltage 230 Volt, single phase, 50 Hz of rated power input-2000 Watt conforming to IS 2082 with standing loss ≤ 0.511 & ≥ 0.465 KWh/24Hr/45°C (5 Star BEE rating wef 01 Jan 2024) having dry powder coating in water stoarge tank of ultra thick super cold rolled steel plates of high-strength, sock proof ABS body using IPX4 technology to protect electrical parts from water to avoid direct contact between cold and hot water flow, glass coated incoloy heating element for good corrosion resistance with execllent resistance to both oxidation and carbonization, panel for temperature setting between 25°C to 75°C to control energy consumption, with 3 preset controls for easy operation, energy saving high density thick PUF insulation for better heatCont/- |
| 8 | Cont/-reterition, having sacrificial magnesium anode rod with steel core to protect water tank from rust and corrosion to enhance the tank life, having safety feature like thermostate, thermal cut off, multifunction valve, shock-safe plug to prevent electric shocks by cutting off the power in case of current leakage suitable for high-rise buildings of 8 bar (0.8 Mpa) pressure including fixing & connecting accessories like mild steel anchor fastener of size 10 x 100mm with nuts and washers, drilling/making hole on wall with provision of stainless steel breaded (SS 304 Graded) connection pipe (01 Pair) in 600 mm long or as per site long enough to connected angle valve for hot & cold water circulation with nuts and washers and testing and including painting MES No. on geyser all as specified and and directed. |
| 9 | S&F 15 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge. |
| 10 | S&F 15mm bore CP angle valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. |
| 11 | S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge. |
| 12 | Supply, installation, testing and commissioning of window type air conditioner of capacity 1.5 TR, electric driven, single phase, with hermetically sealed air compressor, using non-CFC refrigerant, having minimum 5 star energy rating, the work shall include pressure testing with nitrogen, vacuumizing the system with freon/recommended equipment, charginf with non-CFC refrigerant, testing and commissioning for smooth functioning, suitable for wall mounting complete all as specified and directed by Engineer-in-charge. |
| 13 | Supply, installation, testing & commissioning of inverter type split Air Conditioner (hot and cold), 5-in-1 convertible, PM 2.5 Filter with activated Carbon, with indoor , outdoor unit, full function wireless remote and auto restart feature, interconnecting copper tubing, insulation, interconnecting wiring etc in complete as per site requirement to provide rated cooling and heating as per specification laid as below:-(i) Rated Tonnage Capacity Range : 2.00 TR (ii) Rated Cooling Capacity in Watt : 6400 (Min - 2231 to Max - 7292)(iii) Rated Heating Capacity in Watt : 6400 (Min - 2238 to Max - 6772)Cont/- |
| 14 | Cont/-(iv) Rated Voltage : Single Phase 230 V ± 10%, 50 Hz(v) Rated Power Input (Cooling / Heating) : 2110/1900 Watt(vi) Rated ISEER : 3.9 or above(vii) Technology of air conditioner : Inverter Technology / twin rotary. Design of AC ambient temp -2ºC to 52ºC(viii) Function : Cooling, De-humidification and Heating(ix) BEE Star rating : Minimum 3 star rating or above as approved (as per specification of BEE effective from 1st July 2022)(x) Cooling/Condensing Coil : 100% Copper(xi) Indoor Noise Level : upto 48 dB(xii) Compressure type : DC/AC inverter-return cooled/Twin Rotary or equivlentCont/- Please Enable Macros to View BoQ information |
| 15 | Cont/-(iv) Rated Voltage : Single Phase 230 V ± 10%, 50 Hz(v) Rated Power Input (Cooling / Heating) : 2110/1900 Watt(vi) Rated ISEER : 3.9 or above(vii) Technology of air conditioner : Inverter Technology / twin rotary. Design of AC ambient temp -2ºC to 52ºC(viii) Function : Cooling, De-humidification and Heating(ix) BEE Star rating : Minimum 3 star rating or above as approved (as per specification of BEE effective from 1st July 2022)(x) Cooling/Condensing Coil : 100% Copper(xi) Indoor Noise Level : upto 48 dB(xii) Compressure type : DC/AC inverter-return cooled/Twin Rotary or equivlentCont/- Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender