Tender For Special Repair To Building No T-48 (Dwo) At Afac Coimbatore

Issued by Statutory Bodies & Commissions/Committees · Coimbatore, Tamil Nadu
Tender Value
19.35 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
0 days left
EMD
38710
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repair To Building No T-48 (Dwo) At Afac Coimbatore

BOQ

Name of Work:- SPECIAL REPAIR TO BUILDING NO T-48 (DWO) AT AFAC COIMBATORE
Sl. No. Item Description
1Taking down cement plaster on brick or stone walls, ceilings, etc including racking out Joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
2Material & Labour for Rendering with WPC in CM 1:4, 15mm thick on othe than fair faces of brick work or concrete surfaces all as specified and directed. Note : WPC shall be measured and paid separately
3Material & Labour for Rendering in CM 1:6, 10mm thick on fair faces of brick work or concrete surfaces complete all as specified and directed.
4Material & Labour for applying two coats of cement base paint over primer on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed.
5Material & Labour prepation of newly plastered wall surfaces and applying two coats of distemper oil-emulsion over a coat of primer over 3mm thick wall care putty on wall on wall all as specified and as directed .
6Supply only Intergral waterproofing compound
7Material & Labour for Rendering in CM 1:3, 5mm thick on fair faces of brick work or concrete surfaces on ceiling complete all as specified and directed.
8Material & Labour for preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and directed.
9Material & Labour for providing anti-termite treatment (post construction) of voids in masonry using chemical emulision one litre per hole at 300 mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand ) to match the existing floors.(Note : work executed by specialized agency who is active member with Indian Pest Control Association)
10Material and labour for complete removal of existing treatment from old wall surfaces and finishing walls with Acrylic Smooth exterior paint of required shade over priming coat of exterior primer all as specified and directed. (Height of bldg upto 15 mtrs)
11Material and labour for complete removal of existing treatment from old wall surfaces, applying wall care putty of 3 mm thickness and applying two coats of acrylic emulsion distemper over a coat of chalk whiting primer complete all as specified and as directed.
12Material & Labour for preparation of old treated surfaces of ceiling and applying two coats of white wash on ceiling complete all as specified and directed.
13Demolition of Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
14Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
15Material & Labour for Glazed coloured ceramic(Designer) tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm/450 x 300 x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface, including finishing of corners with PVC beading all as specified and as directed by Engr-in-charge..
16Material & Labour for Screed bed or bedding layer of mortor 15 mm thick in CM 1:4 for laying floor finishes all as specified and directed.
17Supply and fixing for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade complete all as specified and directed. .
18Supply and fixing for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed. (Note : Work executed by specialized agency who is active member with Indian pest Control Association)
19Material & Labour for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match light shade complete all as specified and directed.
20Material & Labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 as in backing coat of skirting /dado complete all as specified and directed.
21Material & Labour for Anodised aluminium snap grid frame work for false ceiling size of grid 605 x 605 mm complete all as specified and directed.
22Material & Labour for Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
23Material & Labour for Perforated particle board/ tiles 16mm thick for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed.
24Dismantling ceiling boards any description any thickness including cover fillets/grid system etc complete all as specified and directed.
25Hacking out old broken glass (any thickness, size, quality or description) from wooden frames of stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
26Supply and fixing Sheet glass,4.00 mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
27Supply and fix in repairs for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
28Material and labour for preparation of old wood & wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
29Material and labour for preparation of old steel surface over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
30Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
31Material & Labour for brick work with flyash bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed.
32Taking down chowkhats or frames with out taking off the shutters from the frames exc 1.50 sqm and not exc 4.00 sqm each and stacking for issuing under credit complete all as specified and directed.
33Supply and fixing Second class hard wood plain solid chowkhats and frames wrought framed rebated on the solid, rounded or chamferred, put together with glue pinned at joints, complete all as specified and directed.
34Material & Labour for providing anti -termite treatment (Post construction ) At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the sameto match with the existing surface complete all as specified and directed. ( Note : Work executed by specialized agency who is active member with Indian pest control association)
35Supply and fixing for 40mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and both faces are covered with decorative face veneer with lipping/frame to match complete all as specified and directed.
36Material & Labour Second class hard wood Glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, guaze etc. (without sash bars) edges of framing plain chamferred or rounded fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part I kiln seasoned and chemically pressure treated all as specified and directed
37Supply and fixing Floor Door Stopper of Aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floors 140 mm complete all as specified.
38Supply and fixing Butt hinges medium weight cold rolled mild steel, and fixed 100 mm size all as specified and directed
39Supply and fixing Aluminium anodised barrel tower bolts extruded section 200 mm size all as specified and directed
40Material & Labour for Aluminium die cast body Door closer hydraulically regulated,designation No. 3,universal type,suitable for door shutters of 851to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed.
41Supply and fixing 600mm x 450mm bevelled edge looking mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
42Supply and fixing Extruded aluminium alloy handles fabricated type anodised size 150 mm complete all as specified and directed.
43Supply and fixing Aluminium alloy anodized sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed 300mm long complete all as specified and directed.
44Material & Labour for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces all as specified and directed.
45Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings
46Material & Labour for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
47Supply and fixing Plain, galvanised, mild steel sheeting 1 mm thick, in valley gutters (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
48Supply and fixing Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe 410-W (GdeE- 250) quality A complete all as specified and directed.
49Supply and fixing in repairs 110mm dia PVC (SWR) pipe single sockted in any length with rubber ring joints fixed to wall with clamp complete all as specified and directed.
50Supply and fixing 110mm radius PVC (SWR) bends complete all as specified and directed.
51Supply and fixing for Powder Coated aluminium frame for partitions with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
52Supply and fixing Sheet glass, 5.5 mm thick ordinary quality and glazing with EPDM rubber in square exc 0.5 sq. m in each pane complete all as specified and directed.
53Supply and fixing for 12 mm particle board for insulation purposes, fixed with nails to timber/ aluminum frame work complete all as specified and directed.
54Supply and fixing for Powder Coated anodised door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips, ruber neoprene packing, handles 2 NOs in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
55Supply and fixing mortice lock,aluminium 4 levers vertical type size 100mm complete all as specified and directed.
56Supply and fixing 100mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and directed.
57Supply and fixing 150 mm long Aluminium anodised barrel towers bolts of extruded section complete all as specified and directed.
58Removal of Plants/ Shrubs grown on walls/ slabs/beams by making holes or demolition of concrete etc and including applying suitable chemical for killing the roots of Plants, filling of holes with concrete and making good complete all as specified and directed.
59Supply and application of single component, seamless, spray applied, hybrid elastomeric PU based material i.e Nitoproof 725 of Fosroc chemicals (or) sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE over a coat of primer i.e Nitoproof WB primer of Fosroc chemicals (or) diluted sikalastic 590 of Sika India Pvt Ltd (or) equivalent in any approved make as approved by GE, work in patches of min 1 Sqm all as specified and directed
60Material & Labour for cement concrete type c-2, 1:3:6 (40mm graded aggregate) 75 mm thick in plinth protection complete all as specified and directed.
61Material & Labour in repair for 18/19mm Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, complete all as specified and directed.
62Supply and fixing in repair 100mm extruded brass handles, fabricated type polished complete all as specified and directed.
63Supply and fixing brass Locks, cupboard, grade I, size 50 mm complete all as specified and directed.
64Supply and fixing in repair 100 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
65Supply and fixing Ball catches with 8 mm dia steel ball and brass body and striking plate including letting in complete all as specified and directed.
66Supply and fixing for 25 mm dia SS drapery rod , including brackets, decorative knobs at both ends & curtain rings 8 Nos (minimum) complete all as specified and directed. .
67Removal of debris/building material out side the campus including loading and unloading, etc to a distance exc 5Km but n exc 10 km out side the MD land complete all as specified and directed. Note:- Location and permission of depositing the building materials/debris disposal outside the MD land shall rest with contractor at his own arrangement.
68Taking down old unserviceable point wiring (light, fan socket or power) complete, including fixture and fittings such as switches,ceiling rose, pendents, regulators,sockets, light fittings etc.removing materials for keeping for taking credit( credit for above items should be made as per conditions separately) and making good disturbed surface of walls floors etc. all as specified.
69Taking down old unserviceable submain wiring of any size including GI/copper earth continuity conductor in PVC conduit on wall/roof and making good to disturbed surfaces all as directed.
70Taking down Ceiling fan sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
71Refixing only Ceiling fan with and including carrying out cleaning servicing, oiling and greasing of ceiling fans and connecting up including provision of cable from celling rose/ connector to fan complete all as specified and directed. .
72Material & Labour for painting of Ceiling fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
73Taking down exhaust fan, sealing cable end, dismantling blades from fan and keeping in safe custody for reuse at site and making good disturbed surfaces complete all as specified and as directed.
74Refixing only exhaust fan ( In Repair) and connecting up including provision of cable from celling rose/ connector to fan complete all as specified and directed.
75M& L for painting of exhaust fan complete, in situ with synthetic enamal paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
76Disconnecting electric connection and taking down main switch/SPN DB/TPN DB of any size and keep in safe custody for taking credit complete and good/levelling the disturbed surfaces of wall to match with existing surface complete all as specified and directed.
77Supply and laying PVC non metalic conduit including tees, bends, elbows, reducers, and fixing accessaries etc for telephone/TV connection of size 20 mm dia complete all as specified and directed. Note (i) Cutting chases will be Measured and paid seperately (ii) TV/Telephone cable provide by user section .
78Supply and fixing PVC non metalic junction boxes one to four way for telephone/TV connection of size 20 mm dia complete all as specified and directed.
79Material & Labour for concealed Point wiring one light/bell point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases will be Measured and paid seperately.
80Material & Labour for concealed Point wiring one ceiling/exhaust fan point controlled by one, one way switch complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases will be Measured and paid seperately.
81Material & Labour for concealed Point wiringone 05 Amps socket outlet point on same board complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases will be Measured and paid seperately.
82Material & Labour for concealed Point wiring one switch socket outlet point 5 Amps on independent board complete with 1.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 1.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases will be Measured and paid seperately.
83Material & Labour for concealed Point wiring with copper conductor cable FRLS, 2.5 Sqmm for one 3 pin socket outlet, 15 Amps and including 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete with 2.5 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 2.5 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases will be Measured and paid seperately.
84Material & Labour for concealed Point wiring with copper conductor cable FRLS, 4 Sqmm for one 3 pin socket outlet, 15 Amps and including 4 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board complete with 4 sqmm single core PVC insulted FRLS cable 1100 volts grade multistranded copper conductor drawn through in and including 20mm dia PVC rigid non metallic conduit concealed with all accessories such as internal bend, end caps etc complete concealed in walls and surface in ceiling/roof/etc including 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor including fabricated branded modular metal flush box concealed in walls with suitable modular plate with cover with suitable screws for housing switches, socket outlets, fan regulators etc all as specified and as directed. Note : Cutting chases will be Measured and paid seperately.
85S&F Switch Modular 6A single pole, one way, 1 module complete all as specified and as directed.
86Supply and fixing Switch Modular 16A single pole, one way, 1 module complete all as specified and as directed.
87Supply and fixing Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed.
88Supply and fixing socket Modular 6/16A 2/3 pin combined 2 module complete all as specified and as directed.
89Supply and fixing Modular fan regulator step type 120 W, 2 module complete all as specified and as directed.
90Supply and fixing LED lights fitting 1 x 18/ 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
91Supply and fixing LED light fitting mirror type withhigh out put diffuser 2 feet 10 watt 220 V AC decorative type with driver holder and LED lampincluding connecting up with three core flexiblecopper conductor cable of suitable size complete all as specified and directed.
92Supply and fixing LED luminaire round/squre shape 15 watts 220 V AC surface/recessed type with hight efficiency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for foof ceiling/surface including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed.
93Material & Labour for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
94Material & Labour for concealed Sub main wiring by making recess in wall/surface complete with 4 runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
95Material & Labour for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 4 Sqmm inverter/UPS/Solar DB and extra connections, single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
96Material & Labour for concealed Sub main wiring by making recess in wall/surface complete with 2 runs of 2.50Sqmm inverter/UPS/Solar DB and extra connections, single core PVC insulated FRLS cable 1100 volts grade multistranded copper conductor cable with 1 run of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm or higher dia non metallic rigid PVC conduit and conduit accessories suface/concealed in wall/Ceiling etc from Main DB to MCB DB all as specified and as directed by engr - in- charge. Note :- 2 runs of 6 sqmm, + 1 run of 6 sqmm (Earth Cotinuity conductor) and 1 run of PVC conduit shall be measured as one unit length.
97Supply and fixing LED luminaire 600 mm x 600 mm 35/36 watts 240 V AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver holders & LED lamp suitable for any type of ceiling including cionnecting up with driver three core flexible copper conductor of suitable size complete all as specified and directed.
98Supply and fixing LED zoom light 24 to 60/180/360 degree rotation 18 watt WH 220 V AC white decorative type with driver and LED lamp of size 89 x 65 mm celiong cut out 80 mm including connecting up with three core flexiblecopper conductor cable white colour of suitable size complete all as specified and directed.
99Supply and fix MCB DB, SPN, 12 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and directed.
100Supply and fix MCB DB, SPN, 8 ways, double door, 240 volt, Isolated neutral bar with IP54 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and directed.
101Supply and fix MCB DB, vetical MCCB as a incommer TPN, 4 ways, Double door, 415 volt, isolated neutral bar with IP 43 protection, door earthing arrangement with cement spill protector, mechanical impact strength IK09 complete all as specified and directed.
102Supply and fix MCCB 415 volts 16 KA four pole suitable for vertical TPN of capacity 100 amps including taking down unserviceable MCCB complete all as specified and directed.
103Supply and fix MCB SP 6 to 32 Amps, 240Volts, 10 KA, \\"B\\" Curve complete complete all as specified and directed.
104Supply and fixing SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) complete.
105Supply and fix ceiling rose surface type bakelite 65 x 50mm with three terminals.
106Supply and fix modular telphone socket RJ 11 one module including taking down unserviceable socket complete all as specified and directed.
107Supply and fix modular TV coaxial socket one module including taking down unserviceable socket complete all as specified and directed.
108Supply and fix pre wired powerunit with 20 amps mimi MCB and plug top for AC including taking down unserviceable socket complete all as specified and directed.
109Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc and cutting chases for concealed conduit wiring,etc and making good, cutting not exc 10 cm girth complete all as specified and directed.
110M & L for taking down carefully the Split A/C outdoor unit of 1.0/1.5/2.00 TR from installed location after disconnecting the electrical connection and seting aside both indoor/outdoor unit complete refixing the same after complete the repair work including servicing the complete unit with replacement minor parts all as directed

AI Tender Summary

OUR REF NO 57473871
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 19.35 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repair To Building No T-48 (Dwo) At Afac Coimbatore
Basic Detail
Tender No 84333/E8
Bidding Type Tender
Location
City Coimbatore
State Tamil Nadu
Key Dates
Publish Date 11 Sep 2026
Submission Date 01 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 19.35 Lakhs
Tender Fee 500
EMD 38710
Exemption Available
Document List
1281c53a-79ef-46d5-b5be-7e7239449c50.html
84333Tender.pdf
BOQ_884270.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

1281c53a-79ef-46d5-b5be-7e7239449c50.html

pdf

84333Tender.pdf

xls

BOQ_884270.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail