Tender For Setting Up Of Cleanroom For Eod Devices And Pcb Repairs At Nsry (Koc)
Tender Overview
Project Description
Tender for Setting Up Of Cleanroom For Eod Devices And Pcb Repairs At Nsry (Koc)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-Sep-2026 | Corrigendum | Date | 13-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | S & F 80 mm thick wall panel in double skin type, sandwiched with self-extinguishing quality PUF of density not less then 40-45 Kg/Cum. The inner and outer skin shall be of HYLEM sheet. The thickness of inner skin and outer skin of the panel shall not be less than 4mm including necessary fixing arrangements all as per manufacture's instruction and as directed |
| 2 | S & F celing panel in double skin type, 50mm thick, sandwiched with self-extinguishing PUF of density not less than 40-45Kg/Cum. The inner and outer skin in the inner and outer skin shall be of HYLAM sheet. The thickness of inner skin and outer skin of the panel shall not be less than 4mm including necessary fixing arrangements all as per manufacture's instruction and as directed |
| 3 | M & L for coving Corners of Extruded Anodized Aluminum, i.e Coving for wall to wall to ceiling joints to given Clean room inside with no sharp edges to retain dust particles and outer asthetic look all as per manufacture's instruction and as directed |
| 4 | M & L for preparation of surface by abrading the surface manually/mechanically to remove dirt, oil, and other contaminations. All dust and debris should be swept or vacuumed from the surface. Applying 1 coat of conductive adhesive primer and laying of 2 mm thick anistatic self leveling flooring of approved shade/colour all as per manufacture's instruction and as directed |
| 5 | M & L for epoxy coving floor to wall corners in 2 inch dia all as per manufacture's instruction and as directed. |
| 6 | S & F factory made 900mm x 2100mm size Flush door 42 mm thick, roller hinged type single leaf fabricated out of similar material to wall panels specification here in before.The view window of size 300mm width x600 height, 5mm thick double glass duty fixed and sealed to the door panels. The door provided with door closer and lock. The door handles, push plate and hinges in stainless steel. The thickness of door 42 mm including necessary fixing arrangements all as per manufacture's instruction and as directed. |
| 7 | S & F factory made 1500mm x 2100mm size Emergency Flush door 42 mm thick, roller hinged type single leaf fabricated out of similar material to wall panels specification here in before. The view window of size 300mm width x600 height, 5mm thick double glass duty fixed and sealed to the door panels. The door provided with door closer and lock. The door handles, push plate and hinges in stainless steel. The thickness of door 42 mm including necessary fixing arrangements all as per manufacture's instruction and as directed. |
| 8 | S & F both sides flush double floated glass 5mm thick and 1000mm H x 900mm W size and inside pre-coated frame with cover plateand breather holes with silica gel as desiccant provided at the wall panel of the clean room. Sufficient size hermetically sealed glass glazing required to flushd to the panel for either side of viewing panels including necessary fixing arrangements all as per manufacture's instruction and as directed. |
| 9 | Supply,intsall commisioning, testing validation of HVAC system with following:Air Handling unit :double skin DX typewith all accessories and control systemCasing: (i)The housing /casing of the AHU 45mm +/-2mm thick incl metal cladding with double skin construction. (ii)The frame work in aluminium section frame joints witth sturdy strong supporting frame work. (iii)The casing with pre-painted galvanized steel sheet of thickness 0.6mm inside and 0.8mm outside with polyyuerthane insulation injected in between ,panels screwd on to frame work with soft gasket on aluminium frame to make the joints air tight .PUF density 40 kg.cum. (iv)The casing is sectionalised construction with removal panel for access to filter ,cooling coil and fans with others as mixing box,cooling coil,fans,fan motor,refrigerant piping,joints in piping,condensate drain pipes including insulation and supports for all pipes.Air conditioning unit(air cooled and scroll compressor type) (a)ATU-1-5000 CFM /150mm static with minimum 8.5TR DX condensing unit x 2 nos with one heater bank of suitable capacity including one 2 TR unit for processing fresh air complete with the all accssories and control system.(Room Size 9X4.5X2.4 mtr as per drawing) with all standard fittings, safety devices, like HP/LP cutout, Initial filling of refrigerent Gas, PVC drain piping with insulation, SA / RA duct & grills as per approved design ,single phase preventor, overload relays, vibration isolation pads etc required for commissioning and smooth functioning of air-conditioning unit including masonry,structural work for support including construction of foundation for equipment complete |
| 10 | Make-AHU:-ZECO/CITIZEN/ACP,Condensing unit-Bluestar/Daikin/Carrier,Heater-Vilaco/Heatcon,Controls-DANFOSS,Blower-NICOTRA/KRUGER,Motor-CG/ABB,Pulley-FENNARS,Fan- plug type,Compressor-Emperson Copland |
| 11 | Note:1.Contractor should submit design ,specification ,layout diagram & GA drawing of all items for the approval of Accepting officer2.The AC plant and other accessories shall be commissioned by OEM.3.The contractor shall submit a certificate from OEM confirming that the entire AC plant work shall be got installed through them /their accredited agencies duly incorporating their recommended make.For this contractor shall obtain the certificate for this from OEM branch officelocated in kochi.4.The tenderer should visit the site and check the site condition before quoting the tender so as to incorporate any changes needed to install the plant in the location and rate quoted shall be included in the quote.5.First charge of refrigerant ,comperessor ,oil ,lubricant etc and maintaining it at desired level even when leakage occurs during defect liability period is deemed to be resposibility of the tenderer.6.Before commencement of the work contractor shall obtain design details including drawing from OEM and submit the OEM vetted drawing for approval of accepting officer duly supported with all relevant specification of each components of AC plant.7.If required capacity is not available ,next higher capacity shall be provIded by the contractor and same is deemed to be included in the cost. Please Enable Macros to View BoQ information |
| 12 | Note:1.Contractor should submit design ,specification ,layout diagram & GA drawing of all items for the approval of Accepting officer2.The AC plant and other accessories shall be commissioned by OEM.3.The contractor shall submit a certificate from OEM confirming that the entire AC plant work shall be got installed through them /their accredited agencies duly incorporating their recommended make.For this contractor shall obtain the certificate for this from OEM branch officelocated in kochi.4.The tenderer should visit the site and check the site condition before quoting the tender so as to incorporate any changes needed to install the plant in the location and rate quoted shall be included in the quote.5.First charge of refrigerant ,comperessor ,oil ,lubricant etc and maintaining it at desired level even when leakage occurs during defect liability period is deemed to be resposibility of the tenderer.6.Before commencement of the work contractor shall obtain design details including drawing from OEM and submit the OEM vetted drawing for approval of accepting officer duly supported with all relevant specification of each components of AC plant.7.If required capacity is not available ,next higher capacity shall be provIded by the contractor and same is deemed to be included in the cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender