Educational and Research Institute Local Bodies Closing in 22 days TDR #57472419

Tender For Wall Panelling, Wooden Flooring Works And False Ceiling Etc In Swayam Production Centre, Library First Floor, Cutn, Academic C Us

Issued by Local Bodies · Thiruvarur, Tamil Nadu
Tender Value
41.79 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
22 days left
EMD
83593
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvarur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Wall Panelling, Wooden Flooring Works And False Ceiling Etc In Swayam Production Centre, Library First Floor, Cutn, Academic C Us

BOQ

Name of Work:- Wall panelling, wooden flooring works and false ceiling etc in Swayam Production centre, Library first floor, CUTN, Academic C us
Sl. No. Item Description
1Part - A - CIVIL WORK
2Supply and Installation of Anutone or Equivalent Strand Nubby, square edge, magnesite- bonded,2mm wide pinewood fibre core,fully encapsulated with texture finish,Green Pro certified ceiling tile of size 595x1195x15 / 595x595x15mmmm thk having volume density 400Kgs/m3, weight 6kg/m2 suspended using 0.3mm thick Anutone Skelet Trelis T15 metal grid system. Anutone or Equivalent Skelet Trelis T15 ceiling grid system, of 600x1200mm module includes Anutone or Equivalent Skelet WA15W30 with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centres.
3Then suspend the Anutone Skelet MT15W36 with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of Anchor Bolt, Soffit Cleat and Suspension Rod with Levelling Clip at 1200mm centres.Anutone Skelet CT15W12 with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centres in the perpendicular direction to the Main T15. Finally Anutone Skelet CT15W06 with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 in direction parallel to the Main T15 to result in 600x1200mm module. Anutone Strand Nubby panels of size 595x1195x15 / 595x595x 15mm thk shall be placed into the grid size of 600x1200mm. Ensure arrow marks behind the tiles are oriented in one direction to achieve uniform shade. Technical Parameters Fire (Class) – 1 & P Acoustics – NRC upto 0.9 (For E600 Mounting) Thermal conductivity (W/mk)– 0.07 Climate (°C, RH) – 50, 95 Light reflectance (%) – 85 Green(VoC, RC %) – Low, 30 all complete as per the direction of Engineer-in-charge.
4Supply & installation of Anutone Salon Slats Surco made of pinewood E1 grade fiberboard, melamine laminated finish, groove perforated slats L16-2 - (2mm grooves @16mm pitch with 27% open area), backlined with Soundtexblack acoustical fleece of 0.27mm thick, surface density 63g/m2,rear scoring with perf 10mm at 20mm pitch, tongue-groove edge for a seamless look, flame resistant (BS476 part 7) , of size 128 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 (L16), installed by using GI Strut framework system.The GI Strut framework system shall include Strut CC25, fully knurled, sectional thickness 0.45mm, length3600mm, web 50mm, depth of 25mm and equal flanges 15mm is fastened to the wall positioned horizontally or vertically at every 600mm centres.Anutone Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC25 with the help of fasteners at every 400mm centers Anutone Slats Surco Plus of size 128x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge ¢re brackets.
5The system is backlined with Anutone SynthPF 5x25 adhered on wall with dab spots of Anutone stick S7 adhesive. Technical Parameters Fire (Class) – BS476 part 7 , Acoustics – NRC 0.75, Thermal conductivity (W/mk)– na, Climate (°C, RH) – 50, 70, Light reflectance (%) – 75 (Maple Arce),Green (VOC, RC %) – E1, 25 all completeas per the direction of Engineer-in-charge
6Supply and Installation of 100mm Drywall Partition with single layer of Anutone Tufbloc, square edge, Magnesia cement core panels of size 1200x2400x12mm, volume density 1000kgs/m3, weight 12kg/m2,installed by using Anutone Studd framework. The Anutone Studd framework system includes Anutone Studd FC72 Floor/Head channel, sectional thickness 0.55mm, length 3600mm, equal flanges of 32mm and web of 72mm fixed to the floor and soffit ceiling with suitable fasteners at 300mm staggered centers. Anutone Silica noise and fire rated silicon sealant to be caulked along the perimeter of the lining frame before fixing the Anutone Studd channels. Then Anutone Studd SC70 Channel, sectional thickness 0.55mm, length 3600mm, unequal flanges of 34/36mm and web of 70mm should be placed into the floor/head channel positioned vertically at 600mm centers. Extra reinforcement to be provided at openings (doors, windows, etc). Anutone studd RC1 are then fastened horizontally to Anutone Studd SC70 @ 600mm centres on both the sides. Anutone SynthPF, thickness 50mm, width 600mm, is held in position with wiremesh (WireMesh not by Anutone).
7Anutone Tufbloc 1200X2400X12mm is fastened onto the Anutone Studd RC1 behind in staggered manner using self drilling (drill tip) fasteners at 300mm centers. 4mm gap should be maintained between boards on all sides. Repeat the process similarly on the other side of the framework. 4mmgap between Tufbloc boards to be filled in full depth by using Anutone Seam kit as per givenrecommendations and guidelines. Installed partition system is then buffed, smoothed, cleaned, primered and roller paint finished with approved colour as per choice of architect. Technical Parameter of tufbloc Core - Magnesia Fire Rating – upto 150 mins Acoustics – STC upto 50 Climate (OC RH) – 50, 99 Termite resistance – Yes Moisture Absorption - 6.8% after 2hrs and 11.3% after 24hrs soaking Wet Expansion - < 0.02% from ambient to saturation Dry Contraction - ≤ 0.02% from evaporation Moisture Movement - 0.02% Light reflectance – 80% Green (RC %) – 30 Hygiene (VoC, Clean room) – Low, Class 1 Strength - Antisag Impact - 4kg hammer 175mm all complete as per the direction of Engineer-in-charge.
8Providing and fixing 100m wide aluminium skirting of approved brand , the skirting to be fixed over the wall/panell with necessary fixtures as per manufacturers recommendation. All complete as per the specification and or directed by the Engineer
9Supply and Installation of 12mm thick BWP plywood (12mm thick plywood and 1mm thick laminat) backed with using struct Systems (Color/finish as per architect design).
10Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
11Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour
12Two coats
13Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
14Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40 mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge
15Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge
16With cement mortar 1:4 (1cement: 4 coarse sand)
17Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
18Providing and laying 12 mm thick AC-5, grade laminate wooden flooring & skirting of Vista/Virgin or equivalent make and made having 0.2 mm thick direct laminate on top of specially developed substrate core (high density fibre board) of plank size as per manufacturer's specification having smart lock, joint tongue and groove construction including top of skirting should be sealed with 4mm thick teak wood lipping. The under layer has to be a 0.2 mm thick alkali resistant polyethylene sheet of density 30-32 kg. per cum on top to secure the floor. The work shall be carried out as per manufacturer's installation procedure and as per direction of Engineer-in-charge.
19Providing and fixing 16mm thick laminated wooden beading over laminated wooden skirting complete. The work shall be carried out as per manufacturer’s installation procedure and as per the direction of Engineer-in-charge.
20Part - B Electrical Work
21150 W LED Soft Panel Light, 5600K, CRI, TLCI > 95, mManual & DMX Control, fully RDM compliant when in DMX mode, complete with 1 diffuser & 3 Mtr cable, Aluminium housing, black powder coated finish comes with Leaf Barndoor for 150 W LED Panel LightsModel: CLP-150DSMake: Canara Lighting
22200W LED Soft Panel light, 5600K, CRI, TLCI > 95, Manual & DMX Control, fully RDM compliant when in DMX mode, complete with 1 diffuser & 3 Mtr cable, Aluminium housing, black powder coated finish comes with Leaf barn door for 150W LED Panel lightsModel: CLP-901D2SMake: Canara Lighting
23RDM Compatible Digital Lighting console with Minimum following specifications. 1024 Channel, 2 Universe, No. of Direct Fixture Control: Atleast 96, No. of Faders : At least 16, No. of Sub masters: At least 10, At least 3 Encoder Wheels, LCD Display for Navigation, Should support ART-NET Port, Fully RDM Compliant in DMX mode.Model: CANDX-C96Make: Canara Lighting
24Lighting grid over studio area consists of :- 1. 40 NB MS Pipe grid system all over the studio- A area with suitable supsenders to hand the studio lights and the other accessories.Model: FGP-1.2Make: Canara Lighting
25Power control system consisting of :1. Direct Lighting Distribution Board for all the lighting points with necessary Indicators and safety controls.2. Power Junction boxes for Lights & console etc.3. Internal earthing system & installation Hardwares required for successful installation.Make: Canara Lighting
26Digital Dimming system consists of DMX Network for the LED Lights:1. DMX Splitter for the Light dimming network.2. DMX dimming junction boxers, Loop box for the dimming network.3. XLR connectors and Termination plugs.Make: Canara Lighting
27Wiring of Studio luminaries using 3 core 1.5. sq.mm FRLS flexible power cables & DMX signal cables run inside the MS perforated cable trays with termination at the Power distribution centre panel for all points. Scope of works include ELECTRICAL WORKS – STUDIO AND CONTROL ROOM, STAGE (Including Switch Socket, Wiring, Conducting, as per necessary required for General lights and AV equipments)Make: Canara Lighting
28GENERAL LIGHT 36WMake: Philiphs, Crompton, Wipro
29ELECTRICAL WORK (Including Switch socket, Wiring & Conducting etc, for operating Studio and Control room equipmentsMake:Legrand (Switch & socket), Finolex (Wire) etc
30SITC Charges
31Air Conditioner
32Supplying, Installation, Testing & Commissioning of 2.0 TR Split type Air-Conditioner unit of inverter type having following specifications: Rated Cooling Capacity (100% Load) shall not be less than 6100 Watt, BEE Star Rating: 5 Star, ISEER Rating: 5.00 (minimum), Compressor: Inverter Type, Material of Coils: 100% Copper, Remote Control: Cordless Type, Copper Refrigerant Pipe Line & Power Wiring: upto 3 meter length, PVC Drain Pipe: upto 3 meter length complete with outdoor condensing unit & wall mounted evaporating unit, capable of cooling, filtering & dehumidifying, suitable for operation on 230Volt Single Phase AC Supply including providing 5 kVA Voltage Stabilizer having specifications as Voltage Range: 170 - 270V, Digital Display Type, Intelligent Time Delay System, Auto Cutoff, Auto Start facility, Built-in Thermal Overload Protection, Suitable for 2.0TR Inverter Type AC and Outdoor Unit stand complete with installation of all equipments in asthetic manner, insulating the refrigerant pipe, pressure testing of system, charging refrigerant complete as reqd.Make: BlueStar, Dikin, Hitachi, Panasonic, OgeneralStabilizer: Everst & V-guard
33Supply and fixing of extra length of Twin Copper Pipe line duly insulated by suitable thickness nitrile rubber along with PVC insulated copper conductor(for control & Power cabling) suitable for 2.0 TR Split Air-Conditioner from Indoor to units to Outdoor Unit in suitable size PVC flexible Pipe for protection of piping, on the wall surface/ Cable tray etc using suitable clamps etc compelete as per site requirement.Make:ISI make or direction of Engineer In-charge
34Supplying and fixing of following sizes of water pipe of UPVC ( Sch 40) conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required.25 mmMake:ISI make or direction of Engineer In-charge ` Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57472419
AUTHORITY Local Bodies
TENDER VALUE 41.79 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Department Of Higher Education
Work Description Tender for Wall Panelling, Wooden Flooring Works And False Ceiling Etc In Swayam Production Centre, Library First Floor, Cutn, Academic C Us
Basic Detail
Tender No CUTN/ENGG/CVL/Ten/2026-27/11
Bidding Type Tender
Location
City Thiruvarur
State Tamil Nadu
Key Dates
Publish Date 11 Sep 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 41.79 Lakhs
Tender Fee Ref. Documents
EMD 83593
Exemption Not Available
Document List
aedc4bb3-983e-41aa-8679-5491dce58ca9.html
BOQ_972964.xls
Tenderfinalswayam.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 22 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 23 days

Tender Documents

Download All (ZIP) ↓
html

aedc4bb3-983e-41aa-8679-5491dce58ca9.html

xls

BOQ_972964.xls

pdf

Tenderfinalswayam.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders