Agriculture Boards / Undertakings / PSU Closing in 7 days TDR #57472418

Tender For Providing Security Lighting Near Railway Siding Gates By Erection Of Electrical Poles And Cable Laying At Fsd Mandirhasaud.

Issued by Boards / Undertakings / PSU · Raipur, Chhattisgarh
Tender Value
10.43 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
7 days left
EMD
20900
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Raipur → Chhattisgarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Providing Security Lighting Near Railway Siding Gates By Erection Of Electrical Poles And Cable Laying At Fsd Mandirhasaud.

BOQ

Name of Work:- Providing security lighting near Railway Siding Gates by erection of Electrical Poles and cable laying at FSD Mandirhasaud.
Sl. No. Item Description
1Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 4 X 16 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
2Supplying of XLPE insulated & PVC sheathed aluminium conductor armoured cable of 1.1 KV grade of size 2 X 10 sqmm, confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required.
3Laying and fixing of one number PVC insulated and PVC sheathed/XLPE aluminium conductor power cable of 1.1 KV grade, of size upto 35 sq. mm (clamped with 1mm thick saddle) etc. on wall/pole surface, as required.
4Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc.External work
540 mm dia nominal bore
6Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required.
740 mm dia
8Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
963 mm dia (OD-63 mm & ID-51 mm nominal)
10Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required. Upto 35 sq. mm
11Supply of swaged steel tubular pole as per IS 2713 with base plate of size 300x300x6mm welded at bottom, necessary hole for cable entry and earthing stud welded at specified height including painting with one coat of red oxide zinc chromate primer.
12Designation 410 SP-8 height 7.50 metre
13Painting with aluminium paint of approved brand and manufacture to give an even shade.Two or more coats on new work.
14Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
15Above 6.5 metre and upto 8.0 metre
16Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
17100 watt
18Supplying, installation, Testing & Commissioning of Street light LED fixture powder coatedpressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70,under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As perANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumptionshould not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
1990 watt
20Supplying and fixing of outdoor type loop in loop out cable junction box fabricated from PVC/1.6 mm MS sheet enclosed weather proof, dust proof, water proof and locking arrangement internally embedded gasket with bottom cable entry plate through cable glands having seperate holes for incoming and outgoing cables and with wires fixed in it having clamps for fitting on steel structure or wall with followings in it. i) HD Connector for 10 to 16 sqmm - 4 No. ii)10 to 16 amp SP 'C' curve 10 KA MCB - 1 No. iii) fixing Clamps with nuts,bots,etc. - 2 Nos.
21Supply and installation of square cross section hollow MS bracket mounted on top of the swaged steel tubular pole welded to pole with full penetration weld/ fixed with appropriate bolts and nuts for installation of the floodlight with bracket outer size 500 mm X 500 mm and 250 mm overhang on each side from the center , finished with one coat of red oxide zinc chromate primer and painted with aluminium paint.
22Supply and fixing following street light pole bracket on existing pole made out of 32 mm dia MS \\"B\\" class pipe welded to min.300 mm long MS pole canopy of suitable dia at an angle including having MS triangular stiffner, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer and painted with aluminium paint etc. as required. Double Over Hang 1.00 metre Long
23Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required .
242 X 10 sq. mm. (19 mm)
254 X 16 sq. mm (28mm)
26Supplying and fixing 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
27Triple pole and neutral
28Double Pole
29Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
30Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
31Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57472418
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 10.43 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Providing Security Lighting Near Railway Siding Gates By Erection Of Electrical Poles And Cable Laying At Fsd Mandirhasaud.
Basic Detail
Tender No 01/Engg./Elect./02/2026-27
Bidding Type Tender
Location
City Raipur
State Chhattisgarh
Key Dates
Publish Date 11 Sep 2026
Submission Date 21 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 10.43 Lakhs
Tender Fee Ref. Documents
EMD 20900
Exemption Not Available
Document List
aa622656-16ee-4e25-8426-c7bd0de99663.html
BOQ_972934.xls
MTF.pdf
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

aa622656-16ee-4e25-8426-c7bd0de99663.html

xls

BOQ_972934.xls

pdf

MTF.pdf

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders