Bids Are invited for Custom Bid For Services - ---- - Erection,Installation, Commissioning Of Single Pole/Double Pole Of 11 Kv And Lt Kv Overhead/Underground Lines And Transformers By Completeing Following Works/Jobs As Per Respo Drawings/Estimate Wi
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - ---- - Erection,Installation, Commissioning Of Single Pole/Double Pole Of 11 Kv And Lt Kv Overhead/Underground Lines And Transformers By Completeing Following Works/Jobs As Per Respo Drawings/Estimate With All Required Materials.Work Includes All Cartage, Carriage, Of Including Received Back Material. T&P, Raw Materials And Any Other Material/Work Which Is Required For Completion Of Said Work But Not Mentioned In This Boq/Estimate. , Carriage Of 13 Mtr Long St Pole From 132 Kv Store Center Mathura To Site Of Work Through The Kacha And Pakka Road Including The Work Of Its Loading And Unloading At The Respective Ends Including The Cost Of Arrangement Of Labour, T&P, Carrier Etc. Required For Proper Completion Of Work. (Distance 00-70 Kms.) , Carriage Of 11 Kv Xlpe Cable Size 3X70 Sq.Mm. Cable Form Store Center Mathura/Agra Including Cost Of Shifting Of Drum From Inside Of Store, Removing Of Cable From Drum And Re-Rolling Of Extra Removed Cable Including Loading & Unloading At Both Ends. , Carriage Of Line Material I.E. Conductor, G.I. Wire Tpmo Stay Rod, Disc Insulator, Cross Arm, Angle Channel And Other Required Material From Store Center At 132 Kv Substation Mathura To The Site Of Work Including Loading And Unloading Of Material At Both Ends. , Erection Of Single Pole Structure 13 Mtrs Long St Pole By Digging Of Pits Fitting Of All Relevant Accessories With Grouting In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms. (Grouting Material Will Be Provided By Contractor) As Per Respo Norms. , Erection Of Double Pole Structure 13 Mtrs Long St Pole By Digging Of Pits Fitting Of All Relevant Accessories With Grouting In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms. (Grouting Material Will Be Provided By Contractor) As Per Respo Norms. , Installation Of Stay Set With Grouting And Nuzzling Etc. As Per Respo Drawing Along With All Routine Material To Be Used For Such Works. , Earthing Of Poles By Fixing Earthing Rods And Binding With Earth Wire As Per Standard Norms Including Cost Of Labour T&P And Required Material For Such Work. , Laying, Sagging Stringing And Binding Of Acsr Weasel Conductor On The Erected Pcc Pole/Stp Including Jumpering As Per Respo Manual. , Laying, Sagging Stringing And Binding Of Acsr Dog Conductor On The Erected Pcc Pole/Stp Including Jumpering As Per Respo Manual. , Laying 3X70 Sqmm Xlpe Cable In Hdpe Pipe/G.I. Pipe/Trench As Per Direction Of Supervising Engineer Work Includes Making Loops And Connecting The Xlpe Cable With Double Pole And Complete Commissing Of The Line As Per Respo Norms. , Providing & Fixing Of Pg Cl Weasel To Weasel As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing And Fixing Of H.D.P.E. 140Mm Odpm Pipe Underground Minimum 2.5 Meters Below By Hdd Method For Laying 11 Kv 3X70 Sqmm Xlpe Cable As Per Direction Of Supervising Engineer And As Per Respo Norms. , Providing And Fixing Of G.I. Pipe 6 Dia As Per Direction Of Supervising Engineer And As Per Respo Norms. , Providing & Fixing Of Alluminium Binding Wire As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing & Fixing Of Alluminium Paint As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing & Fixing Of Number Plate As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing & Fixing Of Danger Board As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing & Fixing Of G.I. Barbed Wire As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing & Fixing Of I Bolt Fo Guarding As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing & Fixing Of G.I. Wire 6&8 Swg As Per Direction Of Supervising Engineer Including Cost Of Labour T&P And Required Material For Such Work. , Providing & Fixing Of 11 Kv Cable Outdoor Jointing Kit Of Size 3X70 Sq.Mm Outdoor Including Removal Of Insulation, Semi-Conductor Of The Cable End And Filling Of Cable Box Complete Work As Per Direction Of Supervising Engineer. , Providing & Fixing Of 11 Kv Cable Intdoor Jointing Kit Of Size 3X70 Sq.Mm Outdoor Including Removal Of Insulation, Semi-Conductor Of The Cable End And Filling Of Cable Box Complete Work As Per Direction Of Supervising Engineer. , Making Of 11 Kv Guarding By Laying Two Nos. Gi Wire Parallel And Fixing Of Lacings (Tilli) At A Distance At 2-3 Mtrs. As Per Direction Of Supervising Engineer/Respo Manual. (Work Includes All Labour, T&P Etc. Required For Proper Completion Of Work) As Per Respo Norms. , Fixing Of Meter Pilfer Box (Service Connection Meter Holding Capacity) Including Its Carriage From Electricity Store Centre Mathura To Site Of Work Including Grouting Of Meter Pillar Box In Ratio 1:4:8 Cement, Sand And Brick Ballast As Per Standard Norms. , Installation Of 11 Kv Ct/Pt Combined Metering Unit On Existing Double Pole Structure Of Large & Heavy, Power Consumers To Avoid Possibility Of Theft Of Energy & 11 Kv Feeders At 33/11 Kv Sub- Station Including The Cost Of Accessories (Nut & Bolt, Pvc Tape Etc.) Required For Proper Completion Of Work Also Provided By The Contractor. (Including Carriage Of New 11 Kv Ct/Pt Combined Metering Unit From Store Center Mathura To Site Of Work.)
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Erection,Installation, Commissioning of Single Pole/Double Pole of 11 KV and LT KV Overhead/Underground Lines and Transformers By Completeing Following Works/Jobs As Per Respo Drawings/Estimate With all required Materials.Work Includes All Cartage, Carriage, of including Received Back Material. T&P, Raw Materials And Any Other Material/Work Which Is Required For Completion of Said Work But Not Mentioned In This Boq/Estimate. | Erection,Installation, Commissioning of Single Pole/Double Pole of 11 KV and LT KV Overhead/Underground Lines and Transformers By Completeing Following Works/Jobs As Per Respo Drawings/Estimate With all required Materials.Work Includes All Cartage, Carriage, of including Received Back Material. T&P, Raw Materials And Any Other Material/Work Which Is Required For Completion of Said Work But Not Mentioned In This Boq/Estimate. |
| 2 | Carriage of 13 Mtr Long ST Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. (Distance 00-70 Kms.) | Carriage of 13 Mtr Long ST Pole from 132 KV Store Center Mathura to site of work through the Kacha and Pakka road including the work of its loading and unloading at the respective ends including the cost of arrangement of labour, T&P, carrier etc. required for proper completion of work. (Distance 00-70 Kms.) |
| 3 | Carriage of 11 KV XLPE Cable size 3x70 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. | Carriage of 11 KV XLPE Cable size 3x70 sq.mm. Cable form Store Center Mathura/Agra including cost of shifting of drum from inside of store, removing of cable from drum and re-rolling of extra removed cable including loading & unloading at both ends. |
| 4 | Carriage of Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel and other required material from Store Center at 132 KV substation Mathura to the site of work including loading and unloading of material at both ends. | Carriage of Line material i.e. conductor, G.I. wire TPMO stay rod, disc insulator, cross arm, Angle channel and other required material from Store Center at 132 KV substation Mathura to the site of work including loading and unloading of material at both ends. |
| 5 | Erection of Single pole structure 13 Mtrs Long ST Pole by digging of pits fitting of all relevant accessories with grouting in ratio 1:4:8 cement, sand and brick ballast as per standard norms. (Grouting material will be provided by contractor) as per RESPO norms. | Erection of Single pole structure 13 Mtrs Long ST Pole by digging of pits fitting of all relevant accessories with grouting in ratio 1:4:8 cement, sand and brick ballast as per standard norms. (Grouting material will be provided by contractor) as per RESPO norms. |
| 6 | Erection of Double pole structure 13 Mtrs Long ST Pole by digging of pits fitting of all relevant accessories with grouting in ratio 1:4:8 cement, sand and brick ballast as per standard norms. (Grouting material will be provided by contractor) as per RESPO norms. | Erection of Double pole structure 13 Mtrs Long ST Pole by digging of pits fitting of all relevant accessories with grouting in ratio 1:4:8 cement, sand and brick ballast as per standard norms. (Grouting material will be provided by contractor) as per RESPO norms. |
| 7 | Installation of stay set with grouting and nuzzling etc. as per RESPO drawing along with all routine material to be used for such works. | Installation of stay set with grouting and nuzzling etc. as per RESPO drawing along with all routine material to be used for such works. |
| 8 | Earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour T&P and required material for such work. | Earthing of poles by fixing earthing rods and binding with earth wire as per standard norms including cost of labour T&P and required material for such work. |
| 9 | Laying, sagging stringing and binding of ACSR Weasel Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. | Laying, sagging stringing and binding of ACSR Weasel Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. |
| 10 | Laying, sagging stringing and binding of ACSR Dog Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. | Laying, sagging stringing and binding of ACSR Dog Conductor on the erected PCC pole/STP including jumpering as per RESPO manual. |
| 11 | Laying 3x70 sqmm XLPE Cable in HDPE Pipe/G.I. Pipe/Trench as per direction of supervising engineer work includes Making loops and connecting the XLPE Cable with double pole and complete commissing of the line as per RESPO Norms. | Laying 3x70 sqmm XLPE Cable in HDPE Pipe/G.I. Pipe/Trench as per direction of supervising engineer work includes Making loops and connecting the XLPE Cable with double pole and complete commissing of the line as per RESPO Norms. |
| 12 | Providing & Fixing of PG Clamp weasel to weasel as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of PG Clamp weasel to weasel as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 13 | Providing and Fixing of H.D.P.E. 140mm ODPM Pipe underground minimum 2.5 Meters below by HDD Method FOR Laying 11 KV 3x70 sqmm XLPE Cable as per direction of supervising engineer and as per RESPO Norms. | Providing and Fixing of H.D.P.E. 140mm ODPM Pipe underground minimum 2.5 Meters below by HDD Method FOR Laying 11 KV 3x70 sqmm XLPE Cable as per direction of supervising engineer and as per RESPO Norms. |
| 14 | Providing and Fixing of G.I. Pipe 6\\" Dia as per direction of supervising engineer and as per RESPO Norms. | Providing and Fixing of G.I. Pipe 6\\" Dia as per direction of supervising engineer and as per RESPO Norms. |
| 15 | Providing & Fixing of Alluminium Binding Wire as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of Alluminium Binding Wire as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 16 | Providing & Fixing of Alluminium Paint as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of Alluminium Paint as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 17 | Providing & Fixing of Number Plate as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of Number Plate as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 18 | Providing & Fixing of Danger Board as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of Danger Board as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 19 | Providing & Fixing of G.I. Barbed Wire as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of G.I. Barbed Wire as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 20 | Providing & Fixing of I Bolt fo Guarding as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of I Bolt fo Guarding as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 21 | Providing & Fixing of G.I. Wire 6&8 SWG as per direction of supervising engineer including cost of labour T&P and required material for such work. | Providing & Fixing of G.I. Wire 6&8 SWG as per direction of supervising engineer including cost of labour T&P and required material for such work. |
| 22 | Providing & Fixing of 11 KV Cable Outdoor Jointing Kit of size 3x70 sq.mm Outdoor including removal of insulation, semi-conductor of the cable end and filling of cable box complete work as per direction of supervising engineer. | Providing & Fixing of 11 KV Cable Outdoor Jointing Kit of size 3x70 sq.mm Outdoor including removal of insulation, semi-conductor of the cable end and filling of cable box complete work as per direction of supervising engineer. |
| 23 | Providing & Fixing of 11 KV Cable intdoor Jointing Kit of size 3x70 sq.mm Outdoor including removal of insulation, semi-conductor of the cable end and filling of cable box complete work as per direction of supervising engineer. | Providing & Fixing of 11 KV Cable intdoor Jointing Kit of size 3x70 sq.mm Outdoor including removal of insulation, semi-conductor of the cable end and filling of cable box complete work as per direction of supervising engineer. |
| 24 | Making of 11 KV Guarding by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. (Work includes All labour, T&P etc. required for proper completion of work) as per RESPO Norms. | Making of 11 KV Guarding by laying two nos. GI wire parallel and fixing of lacings (tilli) at a distance at 2-3 mtrs. as per direction of supervising engineer/RESPO manual. (Work includes All labour, T&P etc. required for proper completion of work) as per RESPO Norms. |
| 25 | Fixing of meter pilfer box (service connection meter holding capacity) including its carriage from Electricity Store Centre Mathura to site of work including grouting of meter pillar box in ratio 1:4:8 cement, sand and brick ballast as per standard norms. | Fixing of meter pilfer box (service connection meter holding capacity) including its carriage from Electricity Store Centre Mathura to site of work including grouting of meter pillar box in ratio 1:4:8 cement, sand and brick ballast as per standard norms. |
| 26 | Installation of 11 KV CT/PT Combined metering unit on existing double pole structure of large & heavy, power consumers to avoid possibility of theft of energy & 11 KV feeders at 33/11 KV sub- station including the cost of accessories (Nut & Bolt, PVC Tape etc.) required for proper completion of work also provided by the contractor. (including carriage of New 11 KV CT/PT combined metering unit from Store Center Mathura to Site of work.) | Installation of 11 KV CT/PT Combined metering unit on existing double pole structure of large & heavy, power consumers to avoid possibility of theft of energy & 11 KV feeders at 33/11 KV sub- station including the cost of accessories (Nut & Bolt, PVC Tape etc.) required for proper completion of work also provided by the contractor. (including carriage of New 11 KV CT/PT combined metering unit from Store Center Mathura to Site of work.) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender