Tender For special Repair Replacement Of Ug Cable And Connected Work And Provn Of Illuminated Airfield Location /Mandatory Signboard For Runway At Afs Tambaram (8944/E8)
Tender Value
47.76 Lakhs
Estimated cost
Bid Submission
02 Oct 2026
15 days left
EMD
95520
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Replacement Of Ug Cable And Connected Work And Provn Of Illuminated Airfield Location /Mandatory Signboard For Runway At Afs Tambaram (8944/E8)
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting / taking down carefully existing unserviceable LT panel board / feeder pillar box any type and capacity including all control switches, fitting and fixtures from different location complete all as specified and directed by Engineer-in-Charge. |
| 2 | Supply, install, testing & commissioning of factory made Indoor LT Panel board of suitable size for 3 phase 415 volt of both side opening double door with push type metal lock, heavy duty wide hinges, separate common across cable aley, made out 2mm CRCA sheet with angle iron frame of size (50 x50 x 6 mm) and MC channel of size (75mm x 40mm) for panel base out door type , free standing cubical type totally enclosed weather dust and vermin proof with front and rear opening with locking arrangement of 440 Volts , 3 Phase 4 wire 50 Hz having Aluminium Bus bar of capacity 1000 Amps duly insulated with IP 54 protection, with powder coating including raised PCC foundation of suitable size complete with following switches, space for 1 No vacant cubical suitable for 63 A cable alley including LT XLPE cable end terminations with glands and lugs complete all as specified and directed by Engineer-in-Charge:- Incoming:i) MCCB 400A, 4 pole, 50KA, 440v,50Hz Adjustable thermal & magnetic setting- 01ii) Multifunction LED meter complete with CT coil including set of indicating lamp RYB -1 set Outgoing :MCCB, 3 pole 320 Amps 36 KA( Adjustable thermal & adjustable magnetic setting )with suitable spreader terminal - 1 NosMCCB, 3 pole 100 Amps 16 KA( Fixed thermal & fixed magnetic setting )with suitable spreader terminal - 2 No MCCB, 3 pole 63 Amps 16 KA( Fixed thermal & fixed magnetic setting ) with suitable spreader terminal - 2 NoMCB, 4 pole 40 Amps -1No |
| 3 | Supply & fixing GI tubing light grade 80 mm bore on poles, under floors, road crossing etc complete all as specified and directed by Engineer-in-Charge.Make of pipe : Jindal (Hisar), Tata , Prakash Surya/Electrosteel |
| 4 | Supply & fixing GI tubing light grade 50 mm bore on poles, under floors, road crossing etc all as reqd at site and complete all as specified and directed by Engineer-in-Charge. Make of pipe : Jindal (Hisar), Tata , Prakash Surya/Electrosteel |
| 5 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and directed by Engineer-in-Charge. |
| 6 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed by Engineer-in-Charge. |
| 7 | Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 8 | S & F of Un-reinforced precast concrete cable cover ,class LV,type-1 size 300X180X40mm complete all as specified and directed by Engineer-in-Charge. |
| 9 | Supply, install, testing & commissioning of factory made Indoor LT Panel board of suitable size for 3 phase 415 volt of both side opening double door with push type metal lock, heavy duty wide hinges, separate common across cable aley, made out 2mm CRCA sheet with angle iron frame of size (50 x50 x 6 mm) and MC channel of size (75mm x 40mm) for panel base out door type , free standing cubical type totally enclosed weather dust and vermin proof with front and rear opening with locking arrangement of 440 Volts , 3 Phase 4 wire 50 Hz having Aluminium Bus bar of capacity 1000 Amps duly insulated with IP 54 protection, with powder coating including raised PCC foundation of suitable size complete with following switches, space for 1 No vacant cubical suitable for 63 A cable alley including LT XLPE cable end terminations with glands and lugs complete all as specified and directed by Engineer-in-Charge:- Incoming:i) MCCB 400A, 4 pole, 36KA, 440v,50Hz Adjustable thermal & magnetic setting- 01ii) Multifunction LED meter complete with CT coil including set of indicating lamp RYB -1 set Outgoing :MCCB, 3 pole 160 Amps 36 KA( Adjustable thermal & adjustable magnetic setting )with suitable spreader terminal - 1 NosMCCB, 3 pole 100 Amps 16 KA( Fixed thermal & fixed magnetic setting )with suitable spreader terminal - 2 No MCCB, 3 pole 63 Amps 16 KA( Fixed thermal & fixed magnetic setting ) with suitable spreader terminal - 2 NoMCB, 4 pole 63 Amps -1No For Street light panel |
| 10 | Taking out UNSV over head ACSR conductor any size complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply, Laying, connecting, testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as specified and directed by Engineer-in-Charge.(excavation, earth work, brick protection and GI pipe etc shall be measured & paid for separately) of following sizes :(a) Cross sectional area 35 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge. |
| 12 | (b ) Cross sectional area 70 Sqmm 3 ½ core complete all as specified and directed by Engineer-in-Charge. |
| 13 | (c) Cross sectional area 95 Sqmm 3 ½ core complete all as specified and directed by Engineer-in-Charge. |
| 14 | (d) Cross sectional area 185 Sqmm 3 ½ core complete all as specified and directed by Engineer-in-Charge. |
| 15 | (e) Cross sectional area 240 Sqmm 3 ½ core complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and directed by Engineer-in-Charge. |
| 17 | M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in pole pole foundation, coping, stay pits etc including provision of necessary form work to aachieve fair finishes surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts/11000 volts connecting and testing for any size complete all as specified and directed by Engineer-in-Charge. (Excavation,earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately) |
| 19 | S & F cable route indicator made out of 25 x 25 x 3 mm angle iron, 300 mm long embedded in PCC block of suitable size with moulded lettter LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation complete all as specified and directed by Engineer-in-Charge. |
| 20 | Taking out UNSV earthing complete all as specified and directed by Engineer-in-Charge. |
| 21 | M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 complete all as specified and directed by Engineer-in-Charge. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover. |
| 22 | Material and labour for Double wall corrugated (DWC) HDPE pipe 63mm X 50 mm bore (OD x ID) confirming to IS 16205 Part-24-2018 for LT UG cable protection along with coupler for the following sizes complete all as specified and directed by Engineer-in-Charge. |
| 23 | Taking out old uNSV GI tubing any capacity and size complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply, Laying, connecting, testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as specified and directed by Engineer-in-Charge.(excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately) of following sizes :(a) Cross sectional area 6 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. |
| 25 | (b) Cross sectional area 10 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. |
| 26 | (c ) Cross sectional area 16 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. |
| 27 | (d) Cross sectional area 25 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. |
| 28 | (e) Cross sectional area 35 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge. |
| 29 | (f) Cross sectional area 50 Sqmm 3 ½ core complete all as specified and directed by Engineer-in-Charge. |
| 30 | M & L for sub main wiring complete with 2 X 4Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and conduit accessories cocealed on wall / surface on ceiling with suitable clamps / saddles including 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity and making good disturbed portion complete all as specified and directed by Engineer-in-Charge.Note : Two runs of cable and one run of earth continuity cable shall be measured as one unit. |
| 31 | M/L for making groove of size 25mm depth and 8mm wide and filling it with Polyethylene/polisulphide material and complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply, Installation, Testing, Commissioning of Guidance signage board (IP 65 protection) complying ICAO standard of various sizes fabricated as per runway authority from anodized aluminum profile structure & 2mm thick aluminum sheet, 4mm thick long life imported non-specular surface polycarbonate signage sheet, symbols of sign shall be made of self-adhesive film applied on face of polycarbonate sheet. Board shall be illuminated with linear 2X90 watt LED's & driver(s) i/c all other accessories complete incoming supply should be constant through stabilizer 230 Volt 50 Hz, mounting legs with breakable coupling & base frame, secondary leads, providing cement concrete foundation of suitable size & depth for each unit, providing pedestal up to 1 mtr all around the signage with 1:2:4 CC of 150 mm thick & finish with neat cement plaster including excavation and concrete complete as required and confirming -to tenders technical specifications, terms & conditions etc. complete all as specified and directed by Engineer-in-Charge.Note:- Stabilizer shell be paid separately and drawing of signage board will be provided by user. |
| 33 | Supply, Install, Testing and Commissioning of Factory fabricated Outdoor type totaly enclosed Sub feeder piller box of size 0.6m x 0.9m x 0.45m made out of 3.15 mm thick CRCA sheet and angle iron of size 40 x 40 x 3 mm floor mounted type with aluminium bus bar of capacity 100 Amp - 04 Nos including two coats of spray synthetic enamel paint over a coat of red oxide, including Voltmeter, Selector Switiches, Phase indication Lamps for Three Phase System, Control Panel & Power Panel Wiring, confirming to IS : 8623, IEC:60439 & CPRI Approved, protection class IP65 with the following accessories complete all as specified and directed by Engineer-in-Charge :- (a) MCCB FP, Thermal Magnetic Release, 415 Volts, 63 Amps 16 KA-01 |
| 34 | Supply, Install, Testing and Commissioning of Factory fabricated Outdoor type totaly enclosed Sub feeder piller box of size 0.6m x 0.9m x 0.45m made out of 3.15 mm thick CRCA sheet and angle iron of size 40 x 40 x 3 mm floor mounted type with aluminium bus bar of capacity 100 Amp - 04 Nos including two coats of spray synthetic enamel paint over a coat of red oxide, including Voltmeter, Selector Switiches, Phase indication Lamps for Three Phase System, Control Panel & Power Panel Wiring, confirming to IS : 8623, IEC:60439 & CPRI Approved, protection class IP65 with the following accessories complete all as specified and directed by Engineer-in-Charge. :- Incoming 63A TPN-01 Provning of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA Make- Volina/MICO/IECO |
| 35 | Supply and laying DWC HDPE (High density polyethylene) pipe of size 63 x 50 mm pipe of following size along with necessary accessories like connectors / bends / tee complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and laying DWC HDPE (High density polyethylene) pipe of size 50 x 38 mm pipe of following size along with necessary accessories like connectors / bends / tee complete all as specified and directed by Engineer-in-Charge. |
| 37 | Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 110 mm dia suitable for 0.4 mpa working pressureand make good after the same complete all as specified and directed by Engineer-in-Charge. |
| 38 | S & F cable route indicator made out of 25 x 25 x 3 mm angle iron, 300 mm long embedded in PCC block of suitable size with moulded lettter LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate) block of suitable size and neccessary earth work and excavation complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fixing of cable Junction Boxes with terminals` IP 66 \\"halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) Cable Size 16/25 Sqmm, Box Dimensions-250 x180 x 98, fixing with 25 Amp TPN for singage board including provision MS angle section 45x45x5 mm on PCC 1:2:4 complete complete all as specified and directed by Engineer-in-Charge.Make- Hensel/Dowells/Sintex |
| 40 | Retrofitting of existing runway singage boards with LED lights, including necessary modifications. Supply and installation of suitable LED fitting , wiring and connection and testing and commissioning of the complete LED lighting system to ensure proper illumination and visibility of the runway signage boards complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 11, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 02, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer