Housing Urban and Rular Development Government Departments Closing in 2 days TDR #57469266

Tender For Deposit-Govt. Medical College Hospital, Thiruvananthapuram - Master Plan - Kiifb Fund - Upgradation Of The Nuclear Medicine Department With High-Dose Therapy Facility-Air Conditioning-Electrical Ac Work

Issued by Government Departments · Thiruvananthapuram, Kerala
Tender Value
36.01 Lakhs
Estimated cost
Bid Submission
18 Sep 2026
2 days left
EMD
50000
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Thiruvananthapuram → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Deposit-Govt. Medical College Hospital, Thiruvananthapuram - Master Plan - Kiifb Fund - Upgradation Of The Nuclear Medicine Department With High-Dose Therapy Facility-Air Conditioning-Electrical Ac Work

BOQ

Name of Work:- DEPOSIT-Govt. Medical College Hospital, Thiruvananthapuram - Master Plan - KIIFB Fund - Upgradation of the Nuclear Medicine Department with High-Dose Therapy Facility-Air conditioning-Electrical AC Work
Sl. No. Item Description
1Air Conditioning
2OD81520/2025-2026:Supply, installation, testing & commissioning of cassette type VRF indoor unit. All indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50hz. Unit shall be provided wireless remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting. 4 Way Cassette 1.5 TR.
3OD81524/2025-2026:Supply, installation, testing & commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSM. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit 6 TR.
4OD81523/2025-2026:Supply, installation, testing & commissioning of high static ductable unit. The indoor unit shall be of the high static ductable as per the requirements specified. All indoor units should have inbuilt drain pump with minimum 700mm vertical lift head. Indoor fan motors shall be BLDC type .all indoors have electronic expansion valve that controls the flow of refrigerant in respond to the load variations of room according to set temperature, which can set by remote controllers. Electricity characteristics for indoor unit shall be 240 volts/ 1phase / 50h Z.I. casing shall be made of galvanized steel sheet (G.S.S) with minimum 0.8 mm thickness. Zinc coating thickness on G.S.S shall be of minimum 220 GSM. ii. Inner and outer side of the casing shall have noise absorbing polyethylene insulation with adequate thickness. iii. Unit shall be provided wired remote controller and it should facilitate on/ off function, change of temperature settings, fan speed setting, operation mode setting, clock function and error code display. High Static Ductable Unit 8 TR.
5OD81521/2025-2026:Supply, Installation, Testing and Commissioning of modular type VRF odu. the outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF /VRV system shall be compact air-cooled type. all the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. Oem should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than ? 3.4 at Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket. 14 HP.
6OD81525/2025-2026:Supply, installation, testing & commissioning of modular type VRF ODU. The outdoor unit shall be factory assembled, weather proof casing, constructed from heavy gauge mild steel panels and coated with baked enamel finish. The unit should be completely factory wired tested with all necessary controls. Outdoors units of the VRF/VRV system shall be compact air-cooled type. All the compressors of the outdoor units must be hermetically sealed BLDC inverter scroll/twin rotary type. OEM should use there on make compressors in VRF /VRV system which is to be supplied. System cop shall not be less than ? 3.4 at Air condition and suitable to operate at heat load proportional to indoor temperature requirement. Aluminum fins of condenser coil shall have anti corrosive epoxy resin ocean black coating along with hydrophilic coating pre coated at factory. The anti-corrosive treatment should have been tested for at least 2500 hrs of standard salt spray test and must have a certified life of minimum 20 years supported by certificate from reputed international institution is mandatory. The treatment should be suitable for areas of high pollution and salt laden air. modular system to be configured as per mention modules given in bracket. 22 HP .
7OD81519/2025-2026:Supply, installation, testing and commissioning of Y joints indoor side, JRBLN03321, JRBLN07121 JRBLN014521.
8OD81518/2025-2026:Supply, installation, testing and commissioning of Y joints outdoor side, ARCNN21.
9OD81522/2025-2026:Supply and Fixing Wireless Remote for Ductable Air conditioning unit.
10OD81530/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supports.Ø6.35
11OD81539/2025-2026: Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ9.53
12OD81528/2025-2026: Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ12.7
13OD81531/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ15.9
14OD81533/2025-2026: Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ19.1
15OD81542/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper support 22.2 mm dia
16OD81543/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ28.6
17OD81540/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ34.9
18OD81536/2025-2026:Supply and providing Refrigerant Copper Piping with 18 G HD Copper pipes, insulated with 19mm thick nitrile rubber tubings finished with glass cloth poly shield coating of approved make with proper supportsØ41.3
1916.12.1.1:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.63 mm sheet
2016.12.1.2:Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.Factory fabricated GSS sheet metal rectangular ducting as per IS 655-2006 Thickness 0.80 mm sheet
21OD81532/2025-2026:Supply, installation, testing and commissioning of Inline Exhaust Air fan suitable for 271 CFM.
22OD81527/2025-2026:Supply, installation, testing and commissioning of Inline Exhaust fan suitable for 176 CFM.
23OD81538/2025-2026:Supply, installation, testing and commissioning of Grill for Fresh Air Supply Size: 150 X 150.
24OD81544/2025-2026:Supply, installation, testing and commissioning of Air Filter for Fresh Air 200 x 125.
25OD81535/2025-2026:Supply and Providing of Fire-retardant Canvass connections with GI matching flanges on both sides.
26OD81541/2025-2026:Supply and installing of acoustic insulation of ducts with Nitrile Rubber 10mm Thick complete as required.
27OD81529/2025-2026:Supply and installing of thermal insulation of ducts with Aluminium foil covered with Nitrile Rubber 13mm Thick complete as required.
2816.17:Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminum with aluminum volume control dampers with anti smudge ring and removable core.
2916.18:Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminum without volume control dampers with anti smudge ring and removable core.
30OD81537/2025-2026:Supply, installation, testing & commissioning of drain piping of adequate dia with proper insulation 32 mm Dia.
31OD81534/2025-2026:Supply, installation, testing & commissioning of pedestial /ODU stand for placing VRF ODU.
32OD81526/2025-2026:Charges for supply and filling the R 410 refrigerant gas in the existing air conditioning system
334.1.1:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness
344.1.2:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness
3590.6.5.4:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm
3690.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
37OD135578/2026-2027:Supply ,laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium conductor power cable of 1.1 KV grade conforming to IS 1554/(part I)/1988 for PVC & IS 7098/(part I)/1988 for XLPE of following size on wall surface as required. 4x10 sqmm (clamped with 1mm thick saddle)
38OD81545/2025-2026:Supply and drawing the following sizes of multi-core PVC insulated &FRLS PVC shielded communication cabling 650/1100v grade copper conductor flexible cables in the existing surface/recess conduit as required including giving necessary connections of the following sizes3 core 1.50 sq mm
394.1.4:Supplying and installing following size of perforated painted with powder coatingM.S. cable trays with perforation not more than 17.5%, in convenient sections,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57469266
AUTHORITY Government Departments
TENDER VALUE 36.01 Lakhs
LAST DATE 18-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Deposit-Govt. Medical College Hospital, Thiruvananthapuram - Master Plan - Kiifb Fund - Upgradation Of The Nuclear Medicine Department With High-Dose Therapy Facility-Air Conditioning-Electrical Ac Work
Basic Detail
Tender No PWD/BLDG/EST/12600/2025/AC
Bidding Type Tender
Location
City Thiruvananthapuram
State Kerala
Key Dates
Publish Date 11 Sep 2026
Submission Date 18 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 36.01 Lakhs
Tender Fee 2760
EMD 50000
Exemption Available
Document List
BOQ_1472607.xls
c14fcb80-9688-48e7-81ce-e57e829b2ced.html
MOM.pdf
Tendernotice_1 (19).pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1472607.xls

html

c14fcb80-9688-48e7-81ce-e57e829b2ced.html

pdf

MOM.pdf

pdf

Tendernotice_1 (19).pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders